You are on page 1of 1

35.

GASTURBINEEXHAUSTGASPARAMETERS

Parameter Baseload Baseload Baseloadoperation


operation operation MinimumAmbient
ISOConditions SiteReference Conditions
Conditions
Units

AmbientTemperature
0C 15 43 10
Relativehumidity
% 35(ambient 6035 85
GTLoad
% 100 100 100
ExhaustGasflow
kg/s 125.2124.19 109.55 126.80
ExhaustGasTemp.atGT
diffuseroutlet 0C 483484.8 505.9 481.03
ExhaustGasComposition(v/v)
Argon
%vol 0.90 0.88 0.9035
Nitrogen
% 75.21 73.79 75.46
Oxygen
% 14.85 14.66 14.88
Carbondioxide
% 2.82 2.72 2.84
Water
% 6.22 7.96 5.91
Sulphurdioxide(1) Min0.0 Min0.0 Min0.0
%

Alltheseparametersshallbeconfirmedduringdetailengineering.Note:
- Fuelgas:NFLG–rich
- Designlife(continuousservice):30years
- Hoursoperation:8000hrs/year
- ExhaustgastemperaturevariationduringstartͲup:120°C/m’
- (1)dependingonfuelgastype

ThanksandRegards

Ing.LeoneGasparini
(ProjectEngineer)

SADELMI Power s.r.l.


ViaValassina2420159Milano(Italy)
tel.+390266823535f.+3902680730
eͲmaill.gasparini@sadelmi.itweb.www.sadelmi.it
skype.leone.gasparini

3 Pleaseconsidertheenvironmentbeforeprintingthisemail

You might also like