DESIGN AND ANALYSIS

OF
MULTI-STORIED BUILDING

By :
K.Uday kumar(09245A0103)
K.Nagendra babu(08241A0123)
Md.Khaja taqiuddin(08241A0117)
CONTENTS
1. INTRODUCTION
2. CODES
3. STATEMENT OF THE PROJECT
4. LOADS ON THE STRUCTURE
5. OBJECTIVE OF STRUCTURAL DESIGN
6. DESIGN AND ANALYSIS
7. REFERENCES
INTRODUCTION

¾Our project is based on the design and analysis


of the multi-storied building.

¾Analysis is done through using the STAAD-PRO.

¾Notation adopted through out the project is


same as in IS-456-2000.
CODES
z IS-456:2000
:DESIGN CODE FOR RCC
STRUCTURES

z IS-875(PART1) :CODE FOR DEAD LOADS

z IS-875(PART2) :CODE FOR IMPOSED LOADS

z IS-875(PART3) :CODE FOR WIND LOADS


STATEMENT OF THE PROJECT :
z 1.Utility of building : Residential buildng
z 2. No of storeys : G+5
z 3.Shape of the building: Rectangular
z 4.No.of staircases : 6 nos
z 5.Type of walls : Brick wall
Geometric details :

Ground Floor : 9.0 MFloor-


Floor Height : 3.0 M
Height of Plinth: 0.6 M above G.L
Depth of Foundation:2 M below G.L
Material details :

Concrete Grade : M25


Grade of steel : HYSD
REINFORCEMENT of Grade Fe415
Bearing Capacity of Soil : 200 KN/M2
Type Of Construction : R.C.C
framed structure
DIFFERENT TYPES OF LOADS ON THE
STRUCTURE

zDead loads
zImposed loads
zWind loads
Dead loads
zInvolvesselfweight of
zRCC slab
zBeams & columns
zPlinth
zWalls
Imposed loads
zImposed also known live loads
zLoad over the floor i.e. load of
persons it is calculated as 0.2 kN/m2
zThis load is applied over the length
of structure
Wind loads
z Wind is air in motion

z Windloads are calculated according to


IS:875(part 3)

z Intensityof wind and exposure are applied


in the directions as required
TYPES OF LOADS IMAGE VIEW
Load combinations
zThe structure should be analysed for
combination of loads as in practice
we have number of loads in various
directions act
zSome of the combinations to be
checked are
z1.5(DL+LL)
z1.5(DL+WL)
OBJECTIVES OF STRUCURAL DEIGN

Structure designed should satisfy the


criteration of ultimate strength.

Structure should satisfy the servicablity

It should satisfy the stablity against


overturning , sliding , and buckling.
z The main objective of the design are

z Foundation design
z Column design
z Beam design
z Slab design
DESIGN PRINCIPLE, ASSUMPTION AND
NOTATION ASSUMED

z The notation adopted throughtout the work is same as in


IS 456-2000
ASSUMPTION IN DESIGN
• Using partial safety factors for loads in accordance with
clause 36.4 of IS 456-2000
• Partial safety factor for material in accordance with
clause 36.4.2 IS 456-2000 is taken as 1.5 for concrete
and 1.15 for steel
• Using partial safety factors in accordance with clause
36.4 of IS 456-2000 combination of load
(D.L +L.L) 1.5
(D.L +L.L +W.L) 1.2
Density of materials used
MATERIAL Density
i) Plain concrete 24.0 KN/m3
ii) Reinforced 25.0 KN/m3
iii) Flooring material (c.m) 20.0KN/m3
iv) Brick masonry 19.0KN/m3
v) Fly ash 5.0KN/m3

LIVELOADS: In accordance with IS 875-86


i) Live load on slabs = 3.0KN/m2
ii) Live load on passage = 3.0KN/m2
iii Live load on stairs = 3.0KN/m2
Structural design
For slabs,Depth is 130 mm provided & min
depth is 90mm
Factored Load on slab is 12Kn/m

For beams,after calculations are done.the


Dimensions of beam is 230*350mm
Factored load on beam is 15.87Kn/m
z Shape of column is Rectangular
z For columns, the dimension of column is
230*500mm
z Factored load on column 1090.10KN

• For footings, the bering capacity of soil is


200Kn/m2
z To provide the dimension of footing is
1.5m*2.7m
ANALYSIS
z Analysis is done using STAAD PRO
developed by BENTLEY
z Once the loads and load combinations are
assigned to the structure, analysis is to be
done
z Analysis is done for RCC structure
Assign the properties of structure
ASSIGN LOADS ON THE SLAB
Load assign on the walls
Assign wind load on the structure
RCC analysis
z Code is assigned as IS:456-2000

z The parameters are assigned to the structure

z Commands to be given are

z concrete design
z Member takeoff
Conclusions
z Staad pro become more and more critical
in the analysis of engineering & scientific
problems
z This facilities for the implementations of
more effective & professional engineering
software
z It should be affordable to promote their
wide spread usage amongst civil engg at a
global scale
REFERENCES
z Structural analysis by S.RAMAMRUTHAM

z IS456-2000 CODE used

z AUTO CAD & STAAD PRO packages

z Design of RCC structures by B.C PUNMIA


Thank you!