You are on page 1of 10

Development Length - Tension

Units
f'c = 3000 psi
fy = 75000 psi
fyt = 60000 psi
As provided = 3.14 * in 2 d
h
As req'd = 3.05 * in 2 As
Atr = 0.22 * in 2
db = 1 in.
n= 0 *
s= 6 * in.
yt = b
1.00
ye = 1.00 * cells with * indicate that this information is optional
ys = 1.00 Atr, n and s are needed only if the Ktr term is used

l= 1.00 As reqd is needed only if the As reqd/As prov reduction is used


cb = 1.50 in. All terms with * can be omitted and a conservative ld will result
y ty e = 1
Ktr = 0.000
(cb + Ktr)/db = 1.500

3 f y ψt ψe ψs
ld = db= 68.47 diameters
40 λ √ f
[ ]
' c b + K tr 68.47 in. (not adjusted for As req'd/As provided
c
db

As req'd/As provided = 0.971338 ld = 66.50 in. (adjusted for As req'd/As provided)

but not less than 12 in.


is optional

uction is used
servative ld will result

As req'd/As provided)
Development Length - Compression

Units
f'c = 4000 psi d
fy = h
60000 psi
As
As = 1.72 in 2
db = 0.75 in.

l= 1.00
As req'd = 1.77 in. b

0 . 02 f y 14.23 in.
l dc = d b=
λ √ f 'c
13.5 in.
≥0 . 0003 f y d b=
A = 8 in.
≥8 in . s req'd

As req'd/As provided = 0.972


Enclosed with spirals or ties (ACI 12.3.3) = 1.00

ldc = 13.83 in. but not less than


1.718519
1.76

13.11864
13.11864

8 in.
Development Length - Hooks

Units
f'c = 4000 psi d
fy = h
60000 psi As
As = 5.06 in 2
db = 1.27 in.

l= 1.00
ye = 1.00 b
As req'd = 4.9 in.
19.0 diameters
0. 02 ψ e f y 24.1 in.
l dh= d b=
λ √f '
c 6 in.
≥6 in .
10.16 in.
8 db
Multipliers
(a) Cover multiplier = 0.7
(b) tie or stirrup multiplier 1
(c) ties 1
(d) As req'd/As provided 0.968

ldc = 16.3 in. but not less than


and not less than
6 in.
10.16 in.
Development Length - Headed Bars

Units
f'c = 4000 psi d
h
fy = 60000 psi As
As = 2.35 in 2
db = 1.00 in.
ye = 1.00
As req'd = 2.20 in. b
15.2 diameters
0. 016 ψ e f y 15.2 in.
l dt = d b=
√f '
c
6 in.
≥6 in .
8 db 8 in.

Multipliers
As req'd/As provided 0.936

ldc = 14.2 in. but not less than 6 in.


and not less than 8 in.
Development Length - Tension
Units
f'c = 4000 psi
fy = 60000 psi
fyt = 60000 psi
b= 14 * in. d
d= 30 * in. h
As
h= 33 * in.
As = 3.79 * in 2
Atr = 0 * in 2
db = 1.27 in.
n= 3 * b
s= 8 * in.
yt = 1.00
ye = 1.00 * cells with * indicate that this information is
ys = 1.00 optional. Mu, b, d, h and As are needed only to calculate

l= 1.00 As reqd. Atr, n and s are needed only if the Ktr term is
cb = 2.00 in. to be used. All terms with * can be omitted and
Mu = 430.90 * ft-k a conservative value of ld will result.
y ty e = 1
Ktr = 0.000
(cb + Ktr)/db = 1.575

3 f y ψt ψe ψs
ld = d = 45.18 diameters
40 λ √ f ' c b + K tr b
c
db
As req'd =
[ 3.44053
] in 2 -
57.38 in. (not adjusted for As req'd

As req'd/As provided = 0.907793 ld = 52.09 in. (adjusted for As req'd/As provided

but not less than 12 in.


d
h
As

b
formation is
needed only to calculate

nly if the Ktr term is


be omitted and

ed for As req'd/As provided)

or As req'd/As provided)