Confining Design for RC Column

Grade of concrete C28/35 (M450) Design code Eurocode 8


Rebar As C-III Calc. column C2-01
Rebar Asw C-II ULS case Tie detailing
Property and coefficients Design values Note
Column general DCM
Fundamental period of the building : T1(s) 3 in horizontal direction interest
Constant acceleration region of the elastic spectrum : Tc(s) 0.8
Behavior factor - q0 4 Follow EC8 5.2.2.2 Table 5.1
Design concrete compressive strength - fcd (MPa) 33.3 f ck = 28 MPa
Column size - bc (mm) 500 b c  h c
Column size - hc (mm) 700
Column clear length - L (mm) 3100
min cover to center of longitudinal bar (mm) 50
Provided longitudinal bars
Design reinforcement strength - fyd (MPa) 339.1 f yk = 390 MPa
Longitudinal bar diameter - dbl (mm) 22
Total number of longitudinal bars - nbl 32
No. of longitudinal bars on size bc - nob 5
No. of longitudinal bars on size hc - noh 9
Axial load for the seismic design NEd (kN) 9500
Provided transverse bars
Design stirrup strength - fywd (MPa) 339.1 f ywk = 295 MPa
Transverse bar diameter - dbw (mm) 10
Transverse bar diameter at column base - dbw2 (mm) 12 from base up to floor 1
Spacing outside critical region - swo (mm) 150
Spacing within critical region - sw (mm) 100
Spacing at column base - sw2 (mm) 100 from base up to floor 1
No. of legs nb parallel to size bc 5
No. of legs nh parallel to size hc 3
Confining design
Region critical length - lc (mm) 700 = max(h c ,l cl /6,450) and if l c /h c < 3 : l c =l cr
Concrete core size - bo (mm) 390 =b c - 2cover min - d bw
Concrete core size - ho (mm) 590 =h c - 2cover min - d bw
Khoảng cách các thanh thép dọc trên cạnh b 98 = b 0 /(n ob -1)
Khoảng cách các thanh thép dọc trên cạnh h 74 = h 0 /(n oh -1)
Spacing between longitudinal restrained bars on size bc 195 = b 0 /(n h -1) for α n
Spacing between longitudinal restrained bars on size hc 148 = h 0 /(n b -1) for α n
Checking spacing between restrained bars OK ≤ 200 mm and 150mm in the corner (EC2 :5.2.3.4(3))
Checking diameter dbw outside critical region OK ≥ (6 , d bl /4)
Checking diameter dbw within critical region OK ≥ (6 , d bl /4)
Checking diameter dbw2 at column base OK ≥ (6 , d bl /4)
Checking spacing swo outside critical region OK ≤ (0,6 h c , 0,6 b c , 240 , 12 d bl )
Checking spacing sw within critical region OK ≤ (0,5 h o , 0,5 b o , 175 , 8 d bl )
Checking spacing swb at column base OK ≤ (0,5 h o , 0,5 b o , 175 , 8 d bl )
Ratio of volumn confining hoops to that of confined core r v = A bw S L bw / ( s w b o h o )
- In critical region: rv 0.0127 r v = A bw ( b o n b +h o n h ) / ( s w b o h o )
- At column base: rv2 0.0183
Checking value r v in critical region OK Following the Eurocode 8 : 0.01< r v <0.04
Checking value r v2 at column base OK Following the Eurocode 8 : 0.01< r v2 <0.04
Design confining index wd  wd = r v f yd / f cd
- In critical region: wd 0.1292
- At column base: wd2 0.1860
Checking index wd within critical region OK ≥ 0.08 (EC8)
Checking index wb2 at column base OK ≥ 0.08 (EC8)

Curvature ductability factor : μ ϕ 7.0000 following EC8 5.2.3.4(3) and 5.4.3.2.2(7)

Critical region : αs 0.7979 (1-0.5s/b o )(1-0.5s/h o )


Base of the column : αs2 0.7979
Critical region : αn 0.7638 1 – [bo /((n h – 1)ho) + ho /((n b – 1)bo)]/3
Base of the column : αn2 0.7638
Confinement effectiveness critical region : α 0.6094 α = αn x αs
Confinement effectiveness at column base : α2 0.6094 α = α n2 x α s2
Normalised design axial force  d = NEd / Acfcd 0.8143
Checking index  d = NEd / Acfcd not OK ≤ 0.65 (EC8)
Checking a wd under the condition:
- awd in critical region 0.0787
- a2wd2 at column base 0.1134
- 30 μϕν dεsy,d.(bc/b0)-0.035 0.3367
- 30 μϕν dεsy,d.(bc/b0)-0.035 at column base 0.3367
- Checking awd in critical region not OK  μ ϕ ν d ε sy,d . ( b c / b  a wd
- Checking a2wd2 at column base not OK  μ ϕ ν d ε sy,d . ( b c / b  a wd
Checking a wd under the condition:

- Checking awd in critical region 2.1    = 4 (recommended)


- Checking a2wd2 at column base 2.8    = 7 (q o = 4)

wd = rv fyd / fcd ; rv = AbwSLbw / (swboho) ; yd = fyd / Es


an = 1 – [bo /((nh – 1)ho) + ho /((nb – 1)bo)]/3 ; d ≤ 0,55 (DCH)
as = (1 - sw/2bo)(1 - sw/2ho) ; d = Ned /(bchcfcd) ; d ≤ 0,65 (DCM)

a s a n  wd  0 , 035   
   → vùng alc móng cột
30  d  yd b c / b o   
→ vùng al khác
c
Es 200000
εsy,d = fyd/Es 0.00170