NEWSLETTER NO.

895
April 17, 2002
Dear Sirs,

The Latest Information on


Direct Printing Out of Measurement Reports

We would like to review the direct printing out available so far as well as the recent
upgrade of the direct printing out in regard with SSD-5500 Ver. 5.0.1 and SSD-5000
Ver. 4.0.1 referred to in the News Letter, No.893.
Our diagnostic ultrasound systems described below are now able to print out OB/GYN
and urology measurement reports directly to Hewlett-Packard printers.

Compatible printers:
Hewlett-Packard printers of PCL (Printer Command Language) level 3 or higher.
Deskjet 95X series (X can be anything) printers meet this requirement.

Compatible software versions for each application:

System SSD-5500 SSD-5000 SSD-4000 SSD-1400 SSD-1000


Application
Obstetrics Ver. 1.0- Ver. 1.0- Ver. 2.0 Ver. 4.0 Ver. 2.0
Urology Ver. 3.0- Ver. 2.0- NO Ver. 4.0 Ver. 2.0
Gynecology Ver. 5.0.1- Ver. 4.0.1- Ver. 2.0 Ver. 6.0 Ver. 4.0
SSD-4000 is not compatible to direct printing out of urology measurement report.

Necessary optional items:

Main unit Isolation unit Serial-parallel converter


SSD-5500 SIU-5500-1 (for common use to Necessary
both SSD-5500 and SSD-5000)
SSD-5000
SSD-4000 Isolation unit is not necessary. Not necessary

SSD-1400 SIU-1400 Necessary


SSD-1000 SIU-1000-2

See next page for the explanation.


-2-

A. In case of SSD-5500/-5000/-1400/-1000:
(1) Isolation units
The necessary isolation units are the same units necessary for ALK-3 data
communication, which were introduced in our newsletter No. 894.
Please be advised that it is not possible to perform ALK-3 data communication and
direct printing out at the same time. (You need to change the connection of the
relevant cable each time for performing direct printing out or ALK-3 data
communication.)
(2) Serial-parallel converter:
A serial-parallel converter needs to be connected to the printer. Please procure a
commercially available converter at your side.
(3) Wire connection:
Please prepare necessary cable at your side.
Wire connection between the ultrasound unit and the printer must be cross
connection.
Therefore, when the connection of the serial-parallel converter is straight, use a
cross-connection cable. When the connection of the serial-parallel converter is
cross, use a straight-connection cable.

B. In case of SSD-4000
(1) Isolation units
SSD-4000 does not need an isolation unit for direct printing out.
However, for ALK-3 data communication, SSD-4000 needs the isolation unit SIU-
4000. (Please refer to the newsletter No. 894 for the details of ALK-3.)
(2) Serial-parallel converter:
SSD-4000 does not need any serial-parallel converter as it has a parallel port.
(3) Wire connection:
SSD-4000 needs a Centronics cable as it has a parallel port.

Yours very truly


ALOKA CO., LTD.

K. Kobayashi
Managing Director & General Manager
International Sales and Marketing Dept.
KK/Ss
Encl. Sample of printouts