Professional Documents
Culture Documents
R eliability
I mmunity
P erformance
1
The R.I.P Principle of RuggedSwitch™
Reliability
“Truly substation hardened!”
Substation Hardened to same level as protective relaying devices!
Meets or exceeds new standards: IEC 61850-3 and IEEE 1613!
Dual Redundant Power Supplies for improved reliability and availability!
-40 to +85°C Operation without fans!
2
NEW IEC Standard: IEC 61850-3
IEC 61850-3
New IEC Standard (Jan/2002)
“Communications networks and
systems in substations”
3
RuggedSwitch™ - IEC 61850-3 EMI Immunity
Performance
6
RuggedSwitch™ - Dual Redundant Power Supplies
Immunity
“Performs in high noise
environments”
Zero-Packet-Loss™ technology under EMI stress.
Class 2 device operation as defined in IEEE 1613
Fiber optical ports for immunity to high noise environments.
8
EPRI Tests: EMI Susceptibility of UTP &
STP Copper Cables
EPRI (AEP) 1997 EMI Immunity Testing
Data Frames
9
Fiber v.s. Copper Quantified
SmartBits(Network Simulator/Analyzer)
Substation LAN
GOOSE
Message
Protective
Relay
PLC
Current Waveform
GOOSE
τ = 16.7ms Message
Protective
Relay
PLC
Performance
“RuggedSwitch™ Operating System
Designed for real-time control!”
IEEE 802.3x Full-Duplex operation for zero collisions.
IEEE 802.1p Priority Queuing for high priority real-time control.
IEEE 802.1Q VLAN for isolating real-time traffic.
IEEE 802.1w Rapid Spanning Tree for fault-tolerant loop architectures.
IGMP Snooping for multicast filtering and management.
SNMP with RMON and Port Mirroring for network management and
diagnostics.
14
Full-Duplex Operation (IEEE 802.3x)
No Collisions! No CSMA/CD!
Tx Rx Tx Rx Tx Rx
Full-Duplex
Ports
1 2 n
In-coming Frames
Priority
Port Transmit Queue
Queue
Mapping
VLAN
VLAN VLAN
VLAN
11 22
IED
IED IED
IED IED
IED IED
IED IED
IED IED
IED IED
IED IED
IED
11 22 33 44 55 66 77 88
Real-time
Real-time Control
Control IEDs
IEDs Data
Data collection
collection IEDs
IEDs
e.g.
e.g. Relays,
Relays, RTUs
RTUs e.g.
e.g. Meters,
Meters, DFR
DFR
PATH 1 PATH 2
100Mbps
100Mbps Fiber
Fiber
Optical Loop
Optical Loop
Fault
Fault
IED
IED IED
IED IED
IED IED
IED
Fault
100Mbps
Fiber Optical
Uplink Ports IED’s with
Fault
IEDs IEDs
IED
IED IED
IED IED
IED IED
IED IED
IED IED
IED IED
IED IED
IED
11 22 33 44 55 66 77 88
Producer Consumer
Consumer IEDs
IEDs
Producer IEDs
IEDs
e.g. e.g.
e.g. Relays, Meters, RTUs
Relays, Meters, RTUs
e.g. Digital
Digital CT/VTs
CT/VTs
•• IP
IP (Layer
(Layer 3)
3) Multicast
Multicast Traffic
Traffic from
from Producer
Producer IEDs
IEDs can
can be
be assigned
assigned to
to
specific
specific Consumer
Consumer IEDs
IEDs interested
interested in
in receiving
receiving the
the streams.
streams.
•• RuggedSwitch™
RuggedSwitch™ supports
supports both
both passive
passive and
and active
active (i.e.
(i.e. routerless)
routerless) IGMP.
IGMP.
20
5 Reasons to put one in your substation
5 Year Warranty !
“Best warranty in the business backed by unsurpassed customer support!”
21