Professional Documents
Culture Documents
Installation Guide: Protection and Control IED Manager PCM600 1MRS756450
Installation Guide: Protection and Control IED Manager PCM600 1MRS756450
INSTALLATION GUIDE
Related items
PCM600 Ver. 2.8 Installation DVD
Content on DVD
PCM600 Setup
PCM600 Ver. 2.8 Readme file
PCM600 Ver. 2.8 Installation Guide
PCM600 Ver. 2.8 Product Guide
1
Protection and Control IED Manager 1MRS756450
PCM600 Issued: 11.12.2007
Version: P/30.6.2016
Prerequisites for using PCM600 Ver. 2.8 can be done by using lusrmgr.msc (“Local Users
and Groups (Local)”). This function provides a
To operate with PCM600, there must be at least
possibility to add both local and network user
one IED Connectivity Package installed and
accounts to PCMSERVER2014 Users Group.
selected to be used with PCM600 Ver. 2.8.
SQL Server 2014 Express
License
PCM600 2.8 is using Microsoft SQL Server 2014
There is no license required for PCM600 Ver. 2.8.
Express. This instance is separate from and
doesn’t interfere with the SQL instance in PCM600
IEC 61850 communication configuration
2.7 and older versions that use SQL Server 2008
Express. The two instances can co-exist.
Separate IEC 61850 communication configuration
software can be purchased through ABB sales
SQL Server 2016 and later versions
representatives.
PCM600 is not compatible with SQL Server 2016
Previous versions of PCM600 or later versions of the SQL Server. PCM600 SQL
Server 2014 instance should not be upgraded to
PCM600 2.8 can be installed in parallel with a
SQL Server 2016 or later.
previous version. If you only want to use PCM600
2.8, you should uninstall the previous version of
PCM600 before installing PCM600 2.8. It is
recommended to install PCM600 versions in Disclaimer
ascending order. E.g. PCM600 2.5 cannot be
The information in this document is subject to change without
installed on top of PCM600 2.8. notice and should not be construed as a commitment by ABB
Oy. ABB Oy assumes no responsibility for any errors that may
If PCM600 2.5 or an older version is uninstalled appear in this document.
after PCM600 2.8 has been installed, PCM600 2.8 © Copyright 2016 ABB Oy
will be broken and must be repaired. This can be
done through Control Panel and Add and Remove All rights reserved.
Programs (Uninstall a Program in Windows 7).
Trademarks
When opening projects in PCM600 2.8 that have ABB is a registered trademark of ABB Group. All other brand or
product names mentioned in this document may be trademarks
been created with previous versions of PCM600, or registered trademarks of their respective holders.
the projects will be converted automatically. After
project conversion, the projects can't be opened
with older PCM600 versions anymore.