You are on page 1of 2

Design of Concrete Corbel (in accordance to NSCP 2010)

Design Data:

Concrete fc' = 28 MPa Horizontal F = 330.00 kN


Steel fy = 276 MPa shear span, av = 300 mm
Service DL = 350.00 kN width, b = 600 mm
Service LL = 150.00 kN friction u = 1.4

Computations:

FACTORED LOADS SHEAR FRICTION REINFORCEMENT


Vu = 660.00 kN reqd Avf = 2277 mm^2
Nuc = 330.00 kN
FLEXURE REINFORCEMENT
PRELIM BRACKET SIZE 210.87 kN-m
brg pl L = 75 mm Mu' = 214.50 kN-m
reqd Ru = 2.822 MPa
DEPTH OF BRACKET FOR SHEAR reqd p = 0.01091
Vn = 880 kN 4/3 p = NA
d1 = 261.90 mm use p = 0.01091
d2 = 264.74 mm reqd Af = 2692 mm^2
d3 = 133.33 mm
shear d = 264.74 mm AXIAL TENSION REINFORCEMENT
reqd An = 1594 mm^2
DEPTH OF BRACKET FOR FLEXURE
Mu = 214.50 kN-m TOTAL MAIN REINFORCEMENT
min p = 0.00406 Asc1 = 4286 mm^2
m = 11.60 Asc2 = 3112 mm^2
Ru = 1.094 MPa reqd Asc = 4286 mm^2
reqd d = 660 mm bar dia. = 28 mm
a/d = 0.45 OK no. of bars = 7.0 pcs
min d = 300 mm use n = 8 pcs
rdance to NSCP 2010) Project Name: THE BLOQ RESIDENCE
L= 400

Vu

av= 300

Nuc

y= 300

h= 600

300

8 - 28 mm dia
4 - 16 mm dia

DEPTH OF BRACKET
try h = 450 mm
d= 411 mm

CLOSED STIRRUP REQUIREMENTS OVERALL BRACKET DIMENSION


Ah = 1346 mm^2 plate t = 25 mm
bar dia. = 16 mm overall h = 450 mm
no. of ties = 3.3 pcs use h = 600 mm
use n = 4 ties bracket L = 388 mm
Ah,furn = 1608 mm^2 use L = 400 mm
spacing = 100 mm outer depth, y = 300 mm
adopt s = 100 mm use y = 300 mm