You are on page 1of 16

FDN DESIGN

Column size 230.00 230.00 mm

Permenant Load 150.00 KN


Variable Load 20.00 KN

Fck 25 N/mm2
Fyk 460 N/mm2

Total Unfactored Load = 170.00 KN

Reqd. Pad Area 1.13 m2 Bearing Capacity o

width of Pad = 1.06 m


THICKNESS of Pad = 177.43 mm

Total Design Load = Ned = 1.35*Gk+1.5*Qk


232.50 KN

Ground Pressure q= Ned/L2 205.15 Kn/m2

Design Moment = 0.5qL(L/2-C/2)2


= 19.01 KNm

If Use Y16 bars -Eff Depth 134.43


If Use Y12 bars -Eff Depth 136.43

As(min) for Y16 = 0.15/100*L*d


= 214.6678 mm2

As(min) for Y12 = 217.8616 mm2

Reinforcement Requirement
Mult Fy d As(mm2)
19014785.5899499 460 131.43 441.112

No. of 16 mm bars required 2.20 200.96


No. of 12 mm bars required 3.90 113.04
Bearing Capacity of the Soil at site =175KN/m2 assumed

Width in Ft 3.49

200.96
FDN DESIGN

Column size 230.00 230.00 mm

Permenant Load 350.00 KN


Variable Load 50.00 KN

Fck 25 N/mm2
Fyk 460 N/mm2

Total Unfactored Load = 400.00 KN

Reqd. Pad Area 2.67 m2 Bearing Capacity o

width of Pad = 1.63 m


THICKNESS of Pad = 272.17 mm

Total Design Load = Ned = 1.35*Gk+1.5*Qk


547.50 KN

Ground Pressure q= Ned/L2 205.31 Kn/m2

Design Moment = 0.5qL(L/2-C/2)2


= 82.49 KNm

If Use Y16 bars -Eff Depth 229.17


If Use Y12 bars -Eff Depth 231.17

As(min) for Y16 = 0.15/100*L*d


= 561.3386 mm2

As(min) for Y12 = 566.2376 mm2

Reinforcement Requirement
Mult Fy d As(mm2)
82493718.234726 460 226.17 1112.108

No. of 16 mm bars required 5.53 200.96


No. of 12 mm bars required 9.84 113.04
Bearing Capacity of the Soil at site =150KN/m2 assumed

Width in Ft 5.36

200.96
FDN DESIGN

Column size 230.00 230.00 mm

Permenant Load 290.00 KN


Variable Load 40.00 KN

Fck 25 N/mm2
Fyk 460 N/mm2

Total Unfactored Load = 330.00 KN

Reqd. Pad Area 2.20 m2 Bearing Capacity o

width of Pad = 1.48 m


THICKNESS of Pad = 247.21 mm

Total Design Load = Ned = 1.35*Gk+1.5*Qk


451.50 KN

Ground Pressure q= Ned/L2 205.23 Kn/m2

Design Moment = 0.5qL(L/2-C/2)2


= 59.76 KNm

If Use Y16 bars -Eff Depth 204.21


If Use Y12 bars -Eff Depth 206.21

As(min) for Y16 = 0.15/100*L*d


= 454.331 mm2

As(min) for Y12 = 458.7808 mm2

Reinforcement Requirement
Mult Fy d As(mm2)
59761943.6087203 460 201.21 905.5972

No. of 16 mm bars required 4.51 200.96


No. of 12 mm bars required 8.01 113.04
Bearing Capacity of the Soil at site =150KN/m2 assumed

Width in Ft 4.87

200.96
FDN DESIGN

Column size 230.00 230.00 mm

Permenant Load 210.00 KN


Variable Load 40.00 KN

Fck 25 N/mm2
Fyk 460 N/mm2

Total Unfactored Load = 250.00 KN

Reqd. Pad Area 1.67 m2 Bearing Capacity o

width of Pad = 1.29 m


THICKNESS of Pad = 215.17 mm

Total Design Load = Ned = 1.35*Gk+1.5*Qk


343.50 KN

Ground Pressure q= Ned/L2 206.10 Kn/m2

Design Moment = 0.5qL(L/2-C/2)2


= 37.44 KNm

If Use Y16 bars -Eff Depth 172.17


If Use Y12 bars -Eff Depth 174.17

As(min) for Y16 = 0.15/100*L*d


= 333.3975 mm2

As(min) for Y12 = 337.2705 mm2

Reinforcement Requirement
Mult Fy d As(mm2)
37440238.1758796 460 169.17 674.8058

No. of 16 mm bars required 3.36 200.96


No. of 12 mm bars required 5.97 113.04
Bearing Capacity of the Soil at site =150KN/m2 assumed

Width in Ft 4.23

200.96
FDN DESIGN

Column size 230.00 230.00 mm

Permenant Load 240.00 KN


Variable Load 60.00 KN

Fck 25 N/mm2
Fyk 460 N/mm2

Total Unfactored Load = 300.00 KN

Reqd. Pad Area 1.50 m2 Bearing Capacity o

width of Pad = 1.22 m


THICKNESS of Pad = 204.12 mm

Total Design Load = Ned = 1.35*Gk+1.5*Qk


414.00 KN

Ground Pressure q= Ned/L2 276.00 Kn/m2

Design Moment = 0.5qL(L/2-C/2)2


= 41.81 KNm

If Use Y16 bars -Eff Depth 161.12


If Use Y12 bars -Eff Depth 163.12

As(min) for Y16 = 0.15/100*L*d


= 296.004 mm2

As(min) for Y12 = 299.6782 mm2

Reinforcement Requirement
Mult Fy d As(mm2)
41810767.7220479 460 158.12 806.1996

No. of 16 mm bars required 4.01 200.96


No. of 12 mm bars required 7.13 113.04
Bearing Capacity of the Soil at site =200KN/m2 assumed

Width in Ft 4.02

200.96
FDN DESIGN

Column size 0.23 0.23 mm

Permenant Load 160.00 KN


Variable Load 40.00 KN

Fck 25 N/mm2
Fyk 460 N/mm2

Total Unfactored Load = 200.00 KN

Reqd. Pad Area 1.00 m2 Bearing Capacity o

width of Pad = 1.00 m


THICKNESS of Pad = 166.67 mm

Total Design Load = Ned = 1.35*Gk+1.5*Qk


276.00 KN

Ground Pressure q= Ned/L2 276.00 Kn/m2

Design Moment = 0.5qL(L/2-C/2)2


= 34.48 KNm

If Use Y16 bars -Eff Depth 123.67


If Use Y12 bars -Eff Depth 125.67

As(min) for Y16 = 0.15/100*L*d


= 185.5 mm2

As(min) for Y12 = 188.5 mm2

Reinforcement Requirement
Mult Fy d As(mm2)
34484476.7465625 460 120.67 871.3426

No. of 16 mm bars required 4.34 200.96


No. of 12 mm bars required 7.71 113.04
Bearing Capacity of the Soil at site =200KN/m2 assumed

Width in Ft 3.28

200.96
FDN DESIGN

Column size 0.23 0.23 mm

Permenant Load 80.00 KN


Variable Load 20.00 KN

Fck 25 N/mm2
Fyk 460 N/mm2

Total Unfactored Load = 100.00 KN

Reqd. Pad Area 0.50 m2 Bearing Capacity o

width of Pad = 0.71 m


THICKNESS of Pad = 117.85 mm

Total Design Load = Ned = 1.35*Gk+1.5*Qk


138.00 KN

Ground Pressure q= Ned/L2 276.00 Kn/m2

Design Moment = 0.5qL(L/2-C/2)2


= 12.19 KNm

If Use Y16 bars -Eff Depth 74.85


If Use Y12 bars -Eff Depth 76.85

As(min) for Y16 = 0.15/100*L*d


= 79.39161 mm2

As(min) for Y12 = 81.51293 mm2

Reinforcement Requirement
Mult Fy d As(mm2)
12189830.7104741 460 71.85 517.2693

No. of 16 mm bars required 2.57 200.96


No. of 12 mm bars required 4.58 113.04
Bearing Capacity of the Soil at site =200KN/m2 assumed

Width in Ft 2.32

200.96
13000000