You are on page 1of 6

DOCUMENT NO.

Rev. No Page
PROJECT

DESN CHKD
TITLE SIGNAGE FOOTING

Design of signage footing

Compressive strength of concrete = 25 MPa


Yeild strength of reinforcement = 415 MPa

Unit wt of soil = 16 kN/cum


Unit weight of concrete = 25 kN/cum
Safe bearing capacity of soil = 130 kN/sqm
Gross Safe Bearing Capacity of soil = 146 kN/sqm
Z

Pu -198 160
0.90 Mx 0 0
MZ 0 0

SC-1 0.12 SC-2 0.12 1.800

0.12 0.12

0.90

0.90 2.5 0.90 X


4.30

Depth of Footing = 1.2 m


Depth of Footing from GL = 1m

Load Case Fx Fy Fz Mx Mz
SC-1 ULT. LOAD 79 -198 0 0 0
SC-2 ULT. LOAD 62 160 0 0 0
141 -38 0 0 0

e = 0.00 -11.78 m
Moment due to eccentricity = 0 447.5 kNm

Weight of soil = 123.84 kN


Weight of footing = 232.2 kN
Axial Load from column = -38 kN
Total vertical load = 318.04 kN

Pressure Calculation
P/A = 41.09 kN/sqm
MX/ZX = 0.00 kN/sqm
MZ/ZZ = 80.67 kN/sqm
P/A+MX/ZX+MZ/ZZ = 121.76 kN/sqm Safe
P/A-MX/ZX+MZ/ZZ = 121.76 kN/sqm
P/A-MX/ZX-MZ/ZZ = -39.58 kN/sqm Tension 50.463
P/A+MX/ZX-MZ/ZZ = -39.58 kN/sqm Tension 24.53

Net upward pressure on footing = 94.96 kN/sqm


DOCUMENT NO.

Rev. No Page
PROJECT

DESN CHKD
TITLE SIGNAGE FOOTING

Top Reinf Bot


Unit
Short Long Short Long
Bending moment at middle = 35.73046 kNm
BM at face of column cantilever portion = 33.50 33.50 kNm
Dia of bar = 16 20 20 20 mm
Clear cover to the main reinfocement = 40 40 50 50 mm
Effective depth of footing = 1152 1150 1152 1150 mm
Area of reinforcement = 1440 1440 1440 mm2
Spacing of reinft. Required = 218 218 218 mm
Provide Spacing of bar = 200 200 200 mm
Spacing bar provided = 300 150 125 125 mm
Safe Safe Safe

Punching shear check


Axial load in the column = 160.00 kN
Net load = 6.35 kN
Eff. Depth = 1152.00 mm
Length = 1.27 m
Width = 1.27 m
Area = 1.62 m
Shear resisting area = 5.9E+06 mm2
Shear stress = 0.00 N/mm2
Allowable punching shear stress = 0.25*sqrt(fck)
= 1.25 N/mm2
Safe

Overturning Check
Total downward load in the column = 318.04 kN
Restoring moment = 683.79 kNm
Overturning moment = -447.50 kNm
FOS = 1.53
Safe
DOCUMENT NO.

Rev. No Page
PROJECT

DESN CHKD
TITLE SIGNAGE FOOTING
DOCUMENT NO.

Rev. No Page
PROJECT

DESN CHKD
TITLE SIGNAGE FOOTING

Design of signage footing

Compressive strength of concrete = 25 MPa


Yeild strength of reinforcement = 415 MPa

Unit wt of soil = 16 kN/cum


Unit weight of concrete = 25 kN/cum
Safe bearing capacity of soil = 130 kN/sqm
Gross Safe Bearing Capacity of soil = 146 kN/sqm
Z

Pu -142 121
0.90 Mx 0 0
MZ 0 0

SC-1 0.12 SC-2 0.12 1.800

0.12 0.12

0.90

0.50 1.8 0.90 X


3.15

Depth of Footing = 1.2 m


Depth of Footing from GL = 1m

Load Case Fx Fy Fz Mx Mz
SC-1 ULT. LOAD 40 -142 0 0 0
SC-2 ULT. LOAD 30.7 121 0 0 0
70.7 -21 0 0 0

e = 0.00 -11.16 m
Moment due to eccentricity = 0 234.325 kNm

Weight of soil = 90.72 kN


Weight of footing = 170.1 kN
Axial Load from column = -21 kN
Total vertical load = 239.82 kN

Pressure Calculation
P/A = 42.30 kN/sqm
MX/ZX = 0.00 kN/sqm
MZ/ZZ = 78.72 kN/sqm
P/A+MX/ZX+MZ/ZZ = 121.01 kN/sqm Safe
P/A-MX/ZX+MZ/ZZ = 121.01 kN/sqm
P/A-MX/ZX-MZ/ZZ = -36.42 kN/sqm Tension 51.798
P/A+MX/ZX-MZ/ZZ = -36.42 kN/sqm Tension 23.13

Net upward pressure on footing = 94.21 kN/sqm


DOCUMENT NO.

Rev. No Page
PROJECT

DESN CHKD
TITLE SIGNAGE FOOTING

Top Reinf Bot


Unit
Short Long Short Long
Bending moment at middle = -2.09039 kNm
BM at face of column cantilever portion = 33.24 33.24 kNm
Dia of bar = 16 20 20 20 mm
Clear cover to the main reinfocement = 40 40 50 50 mm
Effective depth of footing = 1152 1150 1152 1150 mm
Area of reinforcement = 1440 1440 1440 mm2
Spacing of reinft. Required = 218 218 218 mm
Provide Spacing of bar = 200 200 200 mm
Spacing bar provided = 300 150 125 125 mm
Safe Safe Safe

Punching shear check


Axial load in the column = 121.00 kN
Net load = -31.44 kN
Eff. Depth = 1152.00 mm
Length = 1.27 m
Width = 1.27 m
Area = 1.62 m
Shear resisting area = 5.9E+06 mm2
Shear stress = -0.01 N/mm2
Allowable punching shear stress = 0.25*sqrt(fck)
= 1.25 N/mm2
Safe

Overturning Check
Total downward load in the column = 239.82 kN
Restoring moment = 377.72 kNm
Overturning moment = -234.33 kNm
FOS = 1.61
Safe