Preselect counter, electrical, incrementing 011435

1/1

Design
The unit consists of an electrical preselect counter with connections and two busbars for
the voltage supply. The unit is mounted on the cabinet frame or on a profile plate by
means of four plug-in adapters.

Function
The electrical preselect counter is adjusted by pressing the white release button and
entering the preselected value simultaneously. The preselected digit is displayed in the
window. The electrical counting pulses are input via connections A1 and A2 and are
added up by the counter. When the preselected value has been reached, the contact
set is actuated. Circuits are opened and closed via the contact sets. The counter is
reset manually via the black reset button or electrically by a reset pulse via connections
R1 and R2. The set preselected value is maintained when the counter is reset.

Note
The preselected value may also be adjusted during operation. The reset signal of the
component is limited to one second. Counting pulses incoming during the reset time are
not processed. The electrical preselect counter functions irrespective of the polarity of
the voltage applied.

Voltage 24 V DC
Contact set 1 changeover switch
Contact load maximum 1 A
Power consumption 2.4 W
Duration of counting pulse minimum 20 ms
Reset manual or electrical
Duration of reset pulse minimum 200 ms
Display 3 digit
Connection for 4 mm plug
Subject to change Technical data