trc = required minimum thickness of closure member

as determined herein
P = internal design pressure (see UG-21) in jacket
chamber
S = maximum allowable stress value (see UG-23)
j = jacket space. Inside radius of jacket minus outside
radius of inner vessel.
Rs = outside radius of inner vessel

CLOSURE RING DESING FOR JACKETED VESSELS (AS PER APPENDIX 9)

DESIGN PRESSURE, P = 0.197 MPa

MAX ALL STRESS VALUE, S = 133.2 MPa

JACKET SPACE, J (IR JACKET - OR VESSEL) = 50.5 mm

OUTSIDE RADIUS OF INNER VESSEL, Rs = 819 mm

CLOSURE THICKNESS, trc = 11.05906 mm


SSELS (AS PER APPENDIX 9)