indicator reason
information, navigation, communication, entertainment -> functionality ->
symbolic control indicators -> traction control system (TCS) activates without
control lamp reason
information, navigation, communication, entertainment ->
functionality ->
symbolic fault indicators -> cruise control system (ADR, ACC)
activates
fault indicator
information, navigation, communication, entertainment -> functionality ->
symbolic fault indicators -> airbag/belt tensioner fault indicator activates
information, navigation, communication, entertainment -> functionality ->
symbolic warning indicators -> alternator control warning activates
information, navigation, communication, entertainment -> functionality ->
symbolic warning indicators -> airbag system warning display activates
information, navigation, communication, entertainment ->
functionality ->
symbolic fault indicators -> engine management fault indicator
activates
(diesel)
information, navigation, communication, entertainment -> functionality ->
symbolic fault indicators -> emission control system fault indicator activates
information, navigation, communication, entertainment -> functionality ->
symbolic fault indicators -> transmission fault indicator activates
Vehicle data
Audi Ges.
Sales types
Type MY Brand Designation Engine code Gearbox code Final drive code
* 2000 A * * *
* 2001 A * * *
* 2002 A * * *
* 2003 A * * *
* 2004 A * * *
* 2005 A * * *
* 2006 A * * *
* 2007 A * * *
* 2008 A * * *
* 2009 A * * *
* 2010 A * * *
* 2011 A * * *
* 2012 A * * *
* 2013 A * * *
* 2014 A * * *
* 2015 A * * *
* 2016 A * * *
* 2017 A * * *
* 2018 A * * *
http://hst.cpn.vwg/hst2/svl/F3F2E3_2C8/B7B0_167/B1B1B6B8B6B2B4_4EC/EDE5F... 3/12/2018
Technical product information 2005366/12 Page 5 of 9
* 2019 A * * *
* 2020 A * * *
* 2021 A * * *
* 2022 A * * *
* 2023 A * * *
* 2024 A * * *
* 2025 A * * *
Documents
Document name
master.xml
http://hst.cpn.vwg/hst2/svl/F3F2E3_2C8/B7B0_167/B1B1B6B8B6B2B4_4EC/EDE5F... 3/12/2018
Technical product information 2005366/12 Page 6 of 9
Connection offline
Technical background
Damaged contacts caused by tests (through-flow check).
Unsuitable measuring tips used in the tests can widen the contacts causing lasting damage (contacts
are overstretched).
Production change
The issue does not involved production. Workshop problem.
Measure
Procedure for 0.63 mm² contacts:
The 0.63 mm contact pen (normal contact on the affected control units) is needed for the check, but
can also be used for other contact bushes with the suitable test contact.
The 0.63 mm contact pen (see illustration) is needed for the check (Part No. 000979007, 000979012
or 000979017). Make sure that the test contact doesn’t get twisted. It must be possible to slide the
test contact into the contact bush of the control unit plug.
Incorrect plug contacts must be replaced with the repair case VAS 1978.
http://hst.cpn.vwg/hst2/svl/F3F2E3_2C8/B7B0_167/B1B1B6B8B6B2B4_4EC/EDE5F... 3/12/2018
Technical product information 2005366/12 Page 7 of 9
The right illustration shows the position of the nano contacts on a 56 pin engine control unit
connector.
http://hst.cpn.vwg/hst2/svl/F3F2E3_2C8/B7B0_167/B1B1B6B8B6B2B4_4EC/EDE5F... 3/12/2018
Technical product information 2005366/12 Page 8 of 9
The proposed repair cable for nano contacts is listed as a 0.5 mm flat contact in the parts catalogue
(see mark in illustration).
Appearance of contact:
Properties:
Nano contacts have a chamber size of 0.4 mm x 0.5 mm (chamber not square).
http://hst.cpn.vwg/hst2/svl/F3F2E3_2C8/B7B0_167/B1B1B6B8B6B2B4_4EC/EDE5F... 3/12/2018
Technical product information 2005366/12 Page 9 of 9
Measuring tips for the measuring appliance V.A.G 1594 D or opposite contacts for the mechanical
check of the nano contacts are not yet available.
A mechanical check of these contacts is not possible at the moment (August 2017).
Use the test box VAS 6606 and test adapter VAS 6606/25 proposed in the Guided Fault Finding for
an electric check (resistance, voltage and current consumption).
A mechanical check of the nano contacts with the measuring appliance V.A.G 1594 D or with 0.63
mm contacts damages the contact and leads to more customer complaints.