You are on page 1of 258

Produktkatalog

Product Catalog
Europe, valid from 01.03.2018
1st Edition

DEOS AG - YOUR COMPETENCE IN


DEOS AG - IHRE KOMPETENZ IN
■ Building Automation
>> Regelungstechnik
■ Control Technology
>> Gebäudemanagement
■ Energy Management
>> Energiemanagement
Content
Page
Control Technology 3

OPEN EMS System 4

OPEN IO Modules 27
Single Room Unit 47
Busses and Protocols 55

Efficiency Solutions 61

OPENdynamics 62
OPENapp HVAC / HVAC Package Units 64

Control Units 67

Touch control 68
LED touch screen 69
TUP – Touch User Panel 72
GALAXY One 74
CORA 78
CODI 80
LVB – Manual Control Level 81

Accessories Control Technology + IT 99

Building Management 119

OPENenergy 120
OPENweb 124
OPENview 132

Zone Control VAV / FCU 137

Sensors 143

Temperature sensors 144


Humidity sensors - Air quality sensors 156
Pressure switches - Pressure transducers - Frost protection thermostat 166
Wireless sensors 175
Accessories - Measurement charts 181

Valves and Actuators 189

Valves and vertical drives 190


Control ball valves / Open-Closed ball valves 208
Zone valves / Actuators 219
Air flap drives 224
Throttling valves 228

Variable Speed Drive 231

Annex 239

Trainings 240
Customer service – Terms of delivery - Contents - alphabetic sorting 243

C 2018 - Technical changes excepted. Pictured products similar. 1


Legal details
Publisher: DEOS AG, Birkenallee 76, 48432 Rheine, Germany
Printing Lammert - Druck Rudolf Lammert GmbH, Bevergerner Straße 51, 48477 Hörstel-Riesenbeck, Germany
company:
Copyright: The text, photos and graphics in this catalog are protected by copyright. No part of this catalog may in any-
way be reproduced or processed, duplicated or disseminated using electronic systems without permission
from DEOS AG.

DEOS® is a registered trademark for distinguishing the goods and services of DEOS AG.

2 C 2018 - Technical changes excepted. Pictures similar.
Control Technology
OPEN EMS

Controllers Page
OPEN 4100 EMS 4
OPEN 3100 EMS 6
OPEN 810 EMS 8
OPEN 710 EMS 9
OPEN 710 / 810 EMS + DALI 10
OPEN 710 / 810 EMS + M-Bus 12
OPEN 600 EMS 14
OPEN 600 EMS basic24 16
OPEN 500 EMS 18
Overview BACnet Controller 20
Overview Controller 22
Overview Controller with DALI and M-Bus interface 24
Redundancy - Hot Standby Controller 25
CAN-HSB (High Safety Bus) 26

C 2018 - Technical changes excepted. Pictured products similar. 3


OPEN 4100 EMS BACnet® - Controllers

Description Technical Information


The OPEN 4100 EMS (Energy Management Sta- BACnet – functionalities
tion) is designed as a native BACnet controller. It The OPEN 4100 EMS supports the BACnet Device Profile „BACnet
supports the BACnet protocol acc. to the ANSI/ Building Controller (B-BC)“. It can be used concurrent as a BACnet
ASHRAE Standard with up to 4000 BACnet Server, BACnet Client and BACnet Router.
objects. The following Data-LinkLayers can be used simultaneously:

The OPEN 4100 EMS is tested acc. to DIN EN • BACnet / IP


16484-6 and BTL/WSPLab Test Plan, certified to • BACnet MS/TP Master
the rules by BACnet Interest Group Europe and • BACnet PTP EIA 232
BTL listed. It has got the AMEV attestation with B • BACnet PTP Modem
profile in the extended version.
Moreover it supports the functionality BACnet Broadcast Management
The OPEN 4100 EMS supports up to 4000 Device (BBMD) incl. Foreign Device Registration for BACnet / IP.
physical data points. Detailed data for supported BACnet Objects and BACnet Services are
given in the data sheet BACnet Implementation Conformance State-
Variant C1 ment (PICS).
• 1 CAN-bus, up to 99 OPEN IO modules

Variant C2 Detailed technical information: page 6 - OPEN 3100 EMS


• 2 CAN-bus, up to 198 OPEN IO modules.
• CAN-HSB safety ring bus activated. For further details: Overview on page 20.
Further information for the CAN-HSB is given
on page 26.

Article Type Art.-No.


OPEN 4100 EMS - Variant C1 DS-OPEN 4100 EMS C1 DS-360093
Native BACnet controller for connection to Ethernet bus
systems. Up to 99 OPEN IO modules with CAN interface
can be connected.
OPEN 4100 EMS - Variant C2 DS-OPEN 4100 EMS C2 DS-360094
Native BACnet controller for connection to Ethernet bus
systems. Up to 198 OPEN IO modules with CAN interface
can be connected.

4 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
BACnet® - Controllers OPEN 4100 EMS

Interfaces Overview of interfaces


Ethernet interface 10/100BaseT, Twisted Pair 1 LED for operating status
Protocols TCP/IP, UDP/IP, Telnet, FTP, BACnet/IP, HTTP
2 Serial interface
Baud rate 10 Mbit/s, 100 Mbit/s, automatic recognition
COM 1, RS232
Interface 2 x RJ 45, two-port switch
Application OPENweb, OPENview, Redundancy, OPC, LAN, 3 Serial interface
BACnet, Service, Modem, TUP COM 2, RS232
4 Fast Ethernet 2 (10/100 BaseT)
CAN-bus 1 CAN 2.0B, electrically isolated ISO 11898
Baud rate 10 kbit/s .. 1 Mbit/s, preset to 50 kbit/s 5 Fast Ethernet 1 (10/100 BaseT)
Interface Connector socket with spring terminals up to 1.5 mm²
Application OPEN IO modules, GALAXY, CORA, CODI, 6 CAN-bus,
LSD-C, IO7, PWH, PLD CAN1 and CAN2 (optional)
7 Serial interface
CAN-bus 2 optional COM 3, RS485

USB 1 .. 2 Hardware: USB 2.0, implemented driver: USB 1.1 8 Power supply
Interface USB A 24 V DC
Application service 9 Universal Serial Bus
USB 2
COM 1 .. 2 RS232
Baud rate 300 .. 115200 bit/s 10 Universal Serial Bus
Interface COM 1 / COM 2 = RJ 45 USB 1

COM 3 RS485
Baud rate 2400 .. 115200 bit/s
Interface COM 3 = RJ 45 and spring terminals up 1.5 mm²

C 2018 - Technical changes excepted. Pictured products similar. 5


OPEN 3100 EMS High End - Controllers

Description Technical Information


The OPEN 3100 EMS (Energy Management Housing
Station) is designed as a high end controller with Dimensions 161 mm x 105 mm x 35 mm (WxHxD)
up to 4000 physical data points for connection to Material Aluminium,
Ethernet bus systems for larger installations. mounting on standard DIN rail 35 mm
Protection IP 20
Variant C1 Cooling by convection, no fan
• 1 CAN-bus, up to 99 OPEN IO modules Temperature range 0 .. 50 °C

Variant C2 Power supply


• 2 CAN-bus, up to 198 OPEN IO modules. Input voltage U(typ.) = 24 V DC, (19 .. 30 V DC)
• CAN-HSB safety ring bus activated. Input current I(typ.) = 250 mA
Further information for the CAN-HSB is given Power consumption approx. 6 W
on page 26. Terminal removable spring terminals up to 1.5 mm²

Microprocessor and memory


CPU PowerPC, 266 MHz
RAM memory 128 MB
NV-RAM 2 MB, battery-buffered
Flash extension 2 GB Micro SD card
Clock battery-buffered real-time clock
Watchdog Hardware-Watchdog

For further details: Overview on page 22.

Article Type Art.-No.


OPEN 3100 EMS - Variant C1 DS-OPEN 3100 C1 EMS DS-360097
Controller for connection to Ethernet bus systems.
Up to 99 OPEN IO modules with CAN interface can
be connected.
OPEN 3100 EMS - Variant C2 DS-OPEN 3100 C2 EMS DS-360098
Controller for connection to Ethernet bus systems.
Up to 198 OPEN IO modules with CAN interface can
be connected.

6 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
High End - Controllers OPEN 3100 EMS

Interfaces Overview of interfaces


Ethernet interface 10/100BaseT, Twisted Pair 1 LED for operating status
Protocols TCP/IP, UDP/IP, Telnet, FTP, HTTP
2 Serial interface
Baud rate 10 Mbit/s, 100 Mbit/s, automatic recognition
COM 1, RS232
Interface 2 x RJ 45, two-port switch
Application OPENweb, OPENview, OPC, LAN, 3 Serial interface
BACnet, Service, Modem, TUP COM 2, RS232
4 Fast Ethernet 2 (10/100 BaseT)
CAN-bus 1 CAN 2.0B, electrically isolated ISO 11898
Baud rate 10 kbit/s .. 1 Mbit/s, preset to 50 kbit/s 5 Fast Ethernet 1 (10/100 BaseT)
Interface Connector socket with sprin terminals up to 1.5 mm²
Application OPEN IO modules, GALAXY, CORA, CODI, 6 CAN-bus,
LSD-C, IO7, PWH, PLD, CAN1 and CAN2 (optional)
7 Serial interface
CAN-bus 2 optional COM 3, RS485

USB 1 .. 2 Hardware USB 2.0, implemented driver USB 1.1 8 Power supply
Interface USB A 24 V DC
Application service 9 Universal Serial Bus
USB 2
COM 1 .. 2 RS232
Baud rate 300 .. 115200 bit/s 10 Universal Serial Bus
Interface COM 1 / COM 2 = RJ 45 USB 1

COM 3 RS485
Baud rate 2400 .. 115200 bit/s
Interface COM 3 = RJ 45 and spring terminals up 1.5 mm²

C 2018 - Technical changes excepted. Pictured products similar. 7


OPEN 810 EMS BACnet® - Controllers

Description Technical Information


The OPEN 810 EMS (Energy Management BACnet – functionalities
Station) controller is designed as a native BACnet The OPEN 810 EMS supports the BACnet Device Profile „BACnet Buil-
controller. It supports the BACnet protocol acc. ding Controller (B-BC)“. It can be used concurrent as a BACnet Server,
to the ANSI/ASHRAE Standard with up to 1000 BACnet Client and BACnet Router.
BACnet objects. The following Data-LinkLayers can be used simultaneously:

The OPEN 810 EMS is tested acc. to DIN EN • BACnet / IP


16484-6 and BTL/WSPLab Test Plan, certified to • BACnet MS/TP Master
the rules by BACnet Interest Group Europe and • BACnet PTP EIA 232
BTL listed. It has got the AMEV attestation with B • BACnet PTP Modem
profile in the extended version.
Moreover it supports the functionality BACnet Broadcast Management
The OPEN 810 EMS has one CAN interface. Device (BBMD) incl. Foreign Device Registration for BACnet / IP.
Three versions for connecting 5, 12 or 32 OPEN Detailed data for supported BACnet Objects and BACnet Services are
IO modules facilitate the use for different sized given in the data sheet BACnet Implementation Conformance State-
installations. ment (PICS).

The controller OPEN 810 EMS supports Detailed technical information: page 9 - OPEN 710 EMS
up to 512 physical data points.
For further details: Overview on page 20 and 24.

Article Type Art.-No.


OPEN 810 EMS DS-OPEN 810/0 EMS DS-360139
Native BACnet Controller for connection to Ethernet bus
systems.
Native BACnet Controller for connection up to 5 OPEN IO DS-OPEN 810/5 EMS DS-360099
modules with CAN interface can be connected.
Native BACnet Controller for connection up to 5 OPEN IO DS-OPEN 810/12 EMS DS-360100
modules with CAN interface can be connected.
Native BACnet Controller for connection up to 5 OPEN IO DS-OPEN 810/32 EMS DS-360101
modules with CAN interface can be connected.

8 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
High Power - Controllers OPEN 710 EMS

Description Technical Information

The OPEN 710 EMS (Energy Management Stati- Housing


on) is designed as a high power controller for the Dimensions (WxHxD) 106 mm x 90 (98) mm x 60 mm
connection to Ethernet bus systems for small and Material Plastic,
medium-size installations. mounting on standard DIN rail 35 mm
Protection IP 20
The OPEN 710 EMS has one CAN interface. Cooling by convection, no fan
Three versions for connecting 5, 12 or 32 OPEN Temperature range 0 .. 50 °C
IO modules facilitate the use for different sized Power supply
installations. Input voltage U(typ.) = 24 V DC (19 .. 30 V DC)
Input current I(typ.) = 160 mA
The OPEN 710 EMS supports up to 512 physical Power consumption approx. 4 W
data points. Terminal removable spring terminals up to 1.5 mm²
Microprocessor and memory
CPU PowerPC, 220 MHz
RAM 128 MB
NV-RAM 2 MB, battery-buffered
Flash-memory 2 GB Micro SD card
Clock battery-buffered real-time clock
Watchdog Hardware-Watchdog
Interfaces
1x CAN-bus baud rate 10 kBit/s .. 1 MBit/s,
1x serial RS232 COM 1 / COM 2 switchable
For further details: Overview on page 22. connection via RJ45
1x serial RS485 galvanically isolated,
removable spring terminals up to 1.5 mm²
2x Fast Ethernet 10/100 BaseT (RJ45), two-port switch
All interfaces are equipped with a status LED.
Article Type Art.-No.
OPEN 710 EMS DS-OPEN 710/0 EMS DS-360154
Controller for connection to Ethernet bus systems.
Controller for connection to Ethernet bus systems. Up to 5 DS-OPEN 710/5 EMS DS-360102
OPEN IO modules with CAN interface can be connected.
Controller for connection up to 12 OPEN IO modules with DS-OPEN 710/12 EMS DS-360103
CAN interface can be connected.
Controller for connection of up to 32 OPEN IO modules DS-OPEN 710/32 EMS DS-360104
with CAN interface can be connected.

C 2018 - Technical changes excepted. Pictured products similar. 9


OPEN 710 / 810 EMS + DALI BACnet® - Controllers

OPEN EMS with DALI interfaces DALI – Digital Addressable Lighting Interface
The hardware of the OPEN 710 / 810 EMS + Operation:
DALI is technically equal to the OPEN 710 / 810 • Up to 4 independent DALI interfaces
EMS. The OPEN 710 / 810 EMS + DALI contains • Up to 64 addresses per DALI interface
additionally the necessary hardware for 4 DALI • RGBW control with 4 DALI addresses
interfaces. • Individual control of single lights ON / OFF / DIMMING
• Support of group addressing
Each DALI interface is build according to the IEC • Support of scene configuration
62386 and can manage up to 64 DALI addres- Commissioning:
ses. As an option, up to 4 DALI interfaces can be • Auto addressing
activated individually. Therefore up to 256 DALI • Auto grouping for RGBW lights possible
addresses can be used. • Auto fault diagnostic function and status control
The DALI interfaces need to be activated on each • Auto fault detection and recording
OPEN EMS + DALI. FUP XL integration:
• Free-programmable DALI functions
Note: • Fully integrated in the engineering tool FUP XL
For the utilization of a DALI control system the • Support of location – and time dependent daylight colour gradients
OPEN EMS + DALI and the activation of at least (Human Biorhythm)
1 DALI interface are required and has to be • Free-programmable colour gradients and -combinations
purchased accordingly. • Support of programmable macros

Article Type Art.-No.


DALI Interface 1S DS-DALI-1S DS-371245
Software module for the management and activation of
1 DALI interface with up to 64 DALI addresses.

DALI Interface 2S DS-DALI-2S DS-371246


Software module for the management and activation of a
total of 2 DALI interfaces with up to 128 DALI addresses.

DALI Interface 3S DS-DALI-3S DS-371247


Software module for the management and activation of a
total of 3 DALI interfaces with up to 192 DALI addresses.

DALI Interface 4S DS-DALI-4S DS-371248


Software module for the management and activation of a
total of 4 DALI interfaces with up to 256 DALI addresses.

10 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
High Power - Controllers OPEN 710 / 810 EMS + DALI

DALI interface 1 up to 64 DALI addresses

DALI interface 2
DALI driver DALI driver
DALI interface 3

DALI interface 4 illuminant illuminant

24 V DC power supply
for DALI interface 1 to 4

Length: each DALI line max. 300 meters


Cable: nominal cross section 1,5 mm²
Topology: any (bus/star/mixed)
DALI interfaces

Article Type Art.-No.


OPEN 710 EMS + DALI DS-OPEN 710/0 EMS DS-360155
Controller with DALI interface. +DALI
OPEN 710 EMS with up to 4 possible DALI interfaces
Controller with DALI interface. DS-OPEN 710/5 EMS DS-360126
OPEN 710 EMS with up to 4 possible DALI interfaces and +DALI
for the connection of up to 5 OPEN IO modules.
Controller with DALI interface. DS-OPEN 710/12 EMS DS-360127
OPEN 710 EMS with up to 4 possible DALI interfaces and +DALI
for the connection of up to 12 OPEN IO modules.
Controller with DALI interface. DS-OPEN 710/32 EMS DS-360128
OPEN 710 EMS with up to 4 possible DALI interfaces and +DALI
for the connection of up to 32 OPEN IO modules.

Article Type Art.-No.


OPEN 810 EMS + DALI DS-OPEN 810/0 EMS DS-360153
Native BACnet controller with DALI interface. +DALI
OPEN 810 EMS with up to 4 possible DALI interfaces.
Native BACnet controller with DALI interface. DS-OPEN 810/5 EMS DS-360123
OPEN 810 EMS with up to 4 possible DALI interfaces and +DALI
for the connection of up to 5 OPEN IO modules.
Native BACnet controller with DALI interface. DS-OPEN 810/12 EMS DS-360124
OPEN 810 EMS with up to 4 possible DALI interfaces and +DALI
for the connection of up to 12 OPEN IO modules.
Native BACnet controller with DALI interface. DS-OPEN 810/32 EMS DS-360125
OPEN 810 EMS with up to 4 possible DALI interfaces and +DALI
for the connection of up to 32 OPEN IO modules.

C 2018 - Technical changes excepted. Pictured products similar. 11


OPEN 710 / 810 EMS + M-Bus BACnet® - Controllers

OPEN EMS with M-B us Interface M-Bus


The hardware of the OPEN 710 / 810 EMS + Operation
M-Bus is technically equal to the OPEN 710 / • 2 independent M-Bus interfaces
810 EMS. The OPEN 710 / 810 EMS + M-Bus • up to 60 M-Bus meters per interface
includes additionally the necessary hardware for 2 • Reading out energy consumptions and other consumption values
M-Bus interfaces.
Commissioning
At each of these interfaces up to 60 M-Bus meters • free record selection at runtime
can be connected directly. No external level con-
verters are required. Integration in FUP XL
• free programmable utilization of the M-Bus records
With the integration of these two M-Bus interfaces • full integration in the programming tool FUP XL
another step in the direction of energy analysis is • support thru macros
complete. Thus, the energy efficiency in buildings
can be measured, evaluated and optimized in a
better way.

OPEN 710 EMS + M-Bus

Artikel Typ Art.-Nr.


OPEN 710 EMS + M-Bus DS-OPEN 710/0 EMS DS-360156
Controller with an M-Bus interface. +M-Bus
OPEN 710 EMS with 2 M-Bus interfaces.
Controller with an M-Bus interface. DS-OPEN 710/5 EMS DS-360133
OPEN 710 EMS with 2 M-Bus interfaces and connection of +M-Bus
up to 5 OPEN IO modules with CAN interface.

Controller with an M-Bus interface. DS-OPEN 710/12 EMS DS-360134


OPEN 710 EMS with 2 M-Bus interfaces and connection of +M-Bus
up to 12 OPEN IO modules with CAN interface.

Controller with an M-Bus interface. DS-OPEN 710/32 EMS DS-360135


OPEN 710 EMS with 2 M-Bus interfaces and connection of +M-Bus
up to 32 OPEN IO modules with CAN interface.

12 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
High Power - Controllers OPEN 710 / 810 EMS + M-Bus

M-Bus interface 1 up to 60 M-Bus meters

M-Bus interface 2

meters

24 V DC Power Supply
for M-Bus interfaces 1 and 2

M-Bus interfaces

OPEN 810 EMS + M-Bus

Artikel Typ Art.-Nr.


OPEN 810 EMS + M-Bus DS-OPEN 810/0 EMS DS-360152
Native BACnet controller with an M-Bus interface. +M-Bus
OPEN 810 EMS with 2 M-Bus interfaces.
Native BACnet controller with an M-Bus interface. DS-OPEN 810/5 EMS DS-360136
OPEN 810 EMS with 2 M-Bus interfaces and connection of +M-Bus
up to 5 OPEN IO modules with CAN interface.

Native BACnet controller with an M-Bus interface. DS-OPEN 810/12 EMS DS-360137
OPEN 810 EMS with 2 M-Bus interfaces and connection of +M-Bus
up to 12 OPEN IO modules with CAN interface.

Native BACnet controller with an M-Bus interface. DS-OPEN 810/32 EMS DS-360138
OPEN 810 EMS with 2 M-Bus interfaces and connection of +M-Bus
up to 32 OPEN IO modules with CAN interface.

C 2018 - Technical changes excepted. Pictured products similar. 13


OPEN 600 EMS BACnet® - Controllers

Description Technical Information


The OPEN 600 EMS (Energy Management BACnet – functionalities
Station) is designed as a native BACnet control- The OPEN 600 EMS supports the BACnet Device Profile „BACnet Buil-
ler. It supports the BACnet protocol acc. to the ding Controller (B-BC)“. It can be used concurrent as a BACnet Server,
ANSI / ASHRAE standard with up to 250 BACnet BACnet Client and BACnet Router.
objects. Following Data-LinkLayers can be used simultaneously:
The OPEN 600 EMS is tested acc. to DIN EN
16484-6 and BTL/WSPLab Test Plan, certified to • BACnet / IP
the rules by BACnet Interest Group Europe and • BACnet MS/TP Master
BTL listed. It has got the AMEV attestation with B • BACnet PTP EIA 232
profile in the extended version. • BACnet PTP Modem
The OPEN 600 EMS is equipped with 32
integrated in- and outputs and can be extended Moreover it supports the functionality BACnet Broadcast Management
with up to 5 additional IO modules accord. to the Device (BBMD) incl. Foreign Device Registration for BACnet / IP.
version. The OPEN 600 EMS can be ordered with Detailed data for supported BACnet Objects and BACnet Services are
and w/o manual control. given in the data sheet BACnet Implementation Conformance State-
It can be connected directly to the analog inputs ment (PICS).
sensors with the measurement elements
10mV/K, Pt1000, Ni1000 DIN and Ni1000 Detailed technical information: page 18 - OPEN 500 EMS
TK5000 as the analog inputs have integrated
transducers. The OPEN 600 EMS supports up to For further details: Overview on page 20-21.
112 physical data points.

Article Type Art.-No.


OPEN 600 EMS
Native BACnet Controller for connection to Ethernet bus
systems. Up to 5 OPEN IO modules with CAN interface
can be connected.
Controller with 32 integrated in- and outputs, DS-OPEN 600/0 EMS DS-360077
w/o manual control.
Controller with 32 integrated in- and outputs, DS-OPEN 600/5 EMS DS-360075
w/o manual control
extendable by up to 5 OPEN IO modules.
Controller with 32 integrated in- and outputs, DS-OPEN 600H/0 EMS DS-360079
with manual control.
Controller with 32 integrated in- and outputs, DS-OPEN 600H/5 EMS DS-360078
with manual control
extendable by up to 5 OPEN IO modules.

14 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
BACnet® - Controllers OPEN 600 EMS

Technical Information
Interfaces:
1 x CAN-bus baud rate 10 kBit/s .. 1 MBit/s, preset 50 kBit/s,
connection via bridge bus connectors
1 x serial RS232 COM 1 / COM 2 switchable, connection via RJ45
1 x serial RS485 galvanically isolated, removable spring terminals up to 1.5 mm²
2 x fast Ethernet 10/100 BaseT (RJ45), two-port switch
All interfaces are equipped with a status LED.
Additional: 1 x LED for operation status
1 x LED Error
1 x LED Run

Onboard IOs:
8 digital inputs
• Input impedance Rin = approx. 5 kOhm against GND
• Digital status inputs, debouncing approx. 30 ms
• Counter of up to 80Hz, debouncing approx. 4 ms
• Status LED
12 digital outputs
• Digital status outputs, max. 80 mA at each output
• Impulse-outputs (software)
• PWM-outputs (software)
• Status LED
8 analog inputs
• Input impedance Rin = approx. 100 kOhm against GND
• AD converter resolution of 24 bit
• 0 .. 10V resolution 0,2 mV
• 0 .. 20 mA (with external 500 Ohm resitor
• 10 mV/K Measurement range -50 .. +150 °C, resolution 0,02 K
• Pt1000 Measurement range -50 .. +650 °C, resolution < 0,1 K
• Ni1000 DIN Measurement range -50 .. +650 °C, resolution < 0,1 K
• Ni1000 TK5000 Measurement range -50 .. +650 °C, resolution < 0,1 K
• Poti Measurement range 0,5 .. 10 kOhm, resolution < 1 Ohm
4 analog outputs
• 0 .. 10V max. 8 mA per output, resolution ca. 100 mV
• Status LED

For further details: Overview on page 20-21.

C 2018 - Technical changes excepted. Pictured products similar. 15


OPEN 600 EMS basic24 BACnet® - Controller

Description Technical Information


The OPEN 600 EMS basic24 is designed as a BACnet – functionalities
native BACnet controller. It supports the BACnet The OPEN 600 EMS supports the BACnet Device Profile „BACnet Buil-
protocol acc. to the ANSI / ASHRAE standard ding Controller (B-BC)“. It can be used concurrent as a BACnet Server,
with up to 250 BACnet objects. BACnet Client and BACnet Router.
The OPEN 600 EMS is tested acc. to DIN EN Following Data-LinkLayers can be used simultaneously:
16484-6 and BTL/WSPLab Test Plan, certified to
the rules by BACnet Interest Group Europe and • BACnet / IP
BTL listed. It has got the AMEV attestation with B • BACnet MS/TP Master
profile in the extended version. • BACnet PTP EIA 232
• BACnet PTP Modem
The OPEN 600 EMS basic24 is equipped with 24
integrated in- and outputs. Moreover it supports the functionality BACnet Broadcast Management
Device (BBMD) incl. Foreign Device Registration for BACnet / IP.
The inputs and outputs are operated via the inte- Detailed data for supported BACnet Objects and BACnet Services are
grated and enabled graphic web server given in the data sheet BACnet Implementation Conformance State-
OPENview. ment (PICS).

Further protocols, such as MODBUS, KNX, Housing


M-Bus, etc. can be enabled in the same way as Dimensions (WxHxD) 160 mm x 90 (98) mm x 60 mm
on the OPEN 600 EMS for a fee. Material Plastic
Mounting on standard DIN rail 35 mm
Sensors with the measurement elements Protection IP 20
10mV/K, Pt1000, Ni1000 DIN and Ni1000 can be Cooling by convection, no fan
connected directly to the analog inputs, as these Temperature range 0 .. 50 °C
have got integrated transducers. Power supply
Input voltage U(typ.) = 24 V DC (19 .. 30 V DC)
The OPEN 600 EMS supports up to 24 physical Input current I(typ.) = 200 mA
data points. Power consumption approx. 5 W
Terminal removable spring terminals up to 1.5 mm²

Artikel Typ Art.-Nr.


OPEN 600 EMS basic 24 DS-OPEN 600/0 EMS basic24 DS-360160
Native BACnet controller for connection to Ethernet
bus systems. Controller with 24 integrated in- and
outputs and activated OPENview graphic.
(w/o manual control and w/o CAN-bus)

16 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
BACnet® - Controller OPEN 600 EMS basic24

1 LED

Technical Information
Microprocessor and memory
CPU PowerPC, 220 MHz
RAM 128 MB
NV-RAM 2 MB, battery-buffered
Flash-memory 2 GB Micro SD card
Clock battery-buffered real-time clock
Watchdog Hardware-Watchdog

Interfaces:
1 x serial RS232 COM 1 / COM 2 switchable, connection via RJ45
1 x serial RS485 galvanically isolated, removable spring terminals up to 1.5 mm²
2 x fast Ethernet 10/100 BaseT (RJ45), two-port switch
All interfaces are equipped with a status LED.
Additional: 1 x LED for operation status
1 x LED Error
1 x LED Run

IOs:
8 digital inputs
• Input impedance Rin = approx. 5 kOhm against GND
• Digital status inputs, debouncing approx. 30 ms
• Counter of up to 80Hz, debouncing approx. 4 ms
• Status LED
4 digital outputs
• Digital status outputs, max. 80 mA at each output
• Impulse-outputs (software)
• PWM-outputs (software)
• Status LED
8 analog inputs
• Input impedance Rin = approx. 100 kOhm against GND
• AD converter resolution of 24 bit
• 0 .. 10V resolution 0,2 mV
• 0 .. 20 mA (with external 500 Ohm resitor
• 10 mV/K Measurement range -50 .. +150 °C, resolution 0,02 K
• Pt1000 Measurement range -50 .. +650 °C, resolution < 0,1 K
• Ni1000 DIN Measurement range -50 .. +650 °C, resolution < 0,1 K
• Ni1000 TK5000 Measurement range -50 .. +650 °C, resolution < 0,1 K
• Poti Measurement range 0,5 .. 10 kOhm, resolution < 1 Ohm
4 analog outputs
• 0 .. 10V max. 8 mA per output, resolution ca. 100 mV
• Status LED
C 2018 - Technical changes excepted. Pictured products similar. 17
OPEN 500 EMS High Power - Controllers

Description Technical Information


The OPEN 500 EMS (Energy Management Housing
Station) is designed as a high power controller for Dimensions (WxHxD) 160 mm x 90 (98) mm x 60 mm
the connection to Ethernet bus systems for small Material Plastic
and medium-size installations. Mounting on standard DIN rail 35 mm
Protection IP 20
The OPEN 500 EMS is equipped with 32 integra- Cooling by convection, no fan
ted in- and outputs and can be extended with up Temperature range 0 .. 50 °C
to 5 additional IO modules. The OPEN 500 EMS Power supply
can be ordered with and w/o manual control. Input voltage U(typ.) = 24 V DC (19 .. 30 V DC)
Input current I(typ.) = 200 mA
The OPEN 500 EMS supports up to 112 physical Power consumption approx. 5 W
data points. Terminal removable spring terminals up to 1.5 mm²
Microprocessor and memory
It can be connected directly to analog inputs CPU PowerPC, 220 MHz
sensors with the measurement elements RAM 128 MB
10mV/K, Pt1000, Ni1000 DIN and Ni1000 NV-RAM 2 MB, battery-buffered
TK5000 as the analog inputs have integrated Flash-memory 2 GB Micro SD card
transducers. Clock battery-buffered real-time clock
Watchdog Hardware-Watchdog

Article Type Art.-No.


OPEN 500 EMS
Controller for connection to Ethernet bus systems. Up to 5
OPEN IO modules with CAN interface can be connected.

Controller with 32 integrated in- and outputs, DS-OPEN 500/0 EMS DS-360081
w/o manual control.
Controller with 32 integrated in- and outputs, DS-OPEN 500/5 EMS DS-360080
w/o manual control
extendable by up to 5 OPEN IO modules.
Controller with 32 integrated in- and outputs, DS-OPEN 500H/0 EMS DS-360083
with manual control.
Controller with 32 integrated in- and outputs, DS-OPEN 500H/5 EMS DS-360082
with manual control
extendable by up to 5 OPEN IO modules.

18 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
High Power - Controllers OPEN 500 EMS

Technical Information
Interfaces
1 x CAN-bus baud rate 10 kBit/s .. 1 MBit/s, preset 50 kBit/s,
connection via bridge bus connectors
1 x serial RS232 COM 1 / COM 2 switchable, connection via RJ45
1 x serial RS485 galvanically isolated, removable spring terminals up to 1.5 mm²
2 x fast Ethernet 10/100 BaseT (RJ45), two-port switch
All interfaces are equipped with a status LED.
Additional: 1 x LED for operation status
1 x LED Error
1 x LED Run

Onboard IOs
8 digital inputs
• Input impedance Rin = approx. 5 kOhm against GND
• Digital status inputs, debouncing approx. 30 ms
• Counter of up to 80Hz, debouncing approx. 4 ms
• Status LED
12 digital outputs
• Digital status outputs, max. 80 mA at each output
• Impulse outputs (software)
• PWM-outputs (software)
• Status LED
8 analog inputs
• Input impedance Rin = approx. 100 kOhm against GND
• AD converter resolution of 24 bit
• 0 .. 10V resolution 0,2 mV
• 0 .. 20 mA (with external 500 Ohm resitor
• 10 mV/K Measurement range -50 .. +150 °C, resolution 0,02 K
• Pt1000 Measurement range -50 .. +650 °C, resolution < 0,1 K
• Ni1000 DIN Measurement range -50 .. +650 °C, resolution < 0,1 K
• Ni1000 TK5000 Measurement range -50 .. +650 °C, resolution < 0,1 K
• Poti Measurement range 0,5 .. 10 kOhm, resolution < 1 Ohm
4 analog outputs
• 0 .. 10V max. 8 mA per output, resolution ca. 100 mV
• Status LED

For further details: Overview on page 23-23.

C 2018 - Technical changes excepted. Pictured products similar. 19


Overview BACnet® Controllers OPEN EMS

Equipment OPEN 4100 EMS OPEN 810 EMS OPEN 600 EMS

Native BACnet Native BACnet Native BACnet

4100 4100 810/0 810/5 810/12 810/32 600/0 600/5


C1 C2 600H/0 600H/5

COM 1 Service ■ ■ ■ ■ ■ ■ ■ ■
COM 2 RS232 ■ ■ ■ ■ ■ ■ ■ ■
COM3 RS485 ■ ■ ■ ■ ■ ■ ■ ■
CAN 1 max. devices** 100 100 8 10 25 50 8 10
OPEN IO module/PWH/PLD 99 99 ─ 5 12 32 ─ 5
Control unit LSD-C 30 30 2 2 2 10 2 2
IO7 / GALAXY / CORA / CODI 96 96 5 5 12 32 5 5
CAN 2 max. devices** ─ 100 ─ ─ ─ ─ ─ ─
OPEN IO module/PWH/PLD ─ 99 ─ ─ ─ ─ ─ ─
Control unit LSD-C ─ 30 ─ ─ ─ ─ ─ ─
IO7 / GALAXY / CORA / CODI ─ 96 ─ ─ ─ ─ ─ ─
BACnet Objects 4000 4000 1000 1000 1000 1000 250 250
Multi-protocol
Ethernet 4 4 4 4 4 4 4 4
(OPENweb Server)
external COM Interfaces*
4 4 2 2 2 2 2 2
(free)
OPENview text-based webserver ■ ■ ■ ■ ■ ■ ■ ■
graphical webserver □ □ □ □ □ □ □ □
M-Bus 250 250 250 250 250 250 10 10
KNX IP max. 50 Data points ─ ─ ─ ─ ─ ─ □ □
max. 1000 Data points □ □ □ □ □ □ ─ ─
CAN-HSB ─ ■ □ ─ ─ ─ ─ ─
OPENdynamics □ □ □ □ □ □ □ □

■ = Standard □ = Optional ─ = not available


** max. number of all devices incl. controller at one bus

* External serial interfaces

Via external TCP/IP Controller (page 110) additional serial interfaces can be connected to one
OPEN EMS. Depending on the version of the TCP/IP controller they can be accomplished as RS232 or RS485.

The OPEN 4100 EMS can be extended with 4 additonal external serial interfaces (COM 5 .. COM 8).
The OPEN 810 EMS and OPEN 600 EMS can be extended with 2 additonal external serial interfaces (COM 5 and COM 6).

20 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN EMS Overview BACnet® Controllers

Available protocols Supported protocols


The freely usable interfaces COM 2 (RS232) and COM 3 (RS485), as
for COM interfaces well as the optional external COM interfaces* offer the possibility for
(Connectivity) the connection of the following protocols to the OPEN EMS.

via RS232 via RS485


■ 2 x Modem ■ 1 x BACnet® MS/TP
■ 1 x Multi-protocol ■ 1 x MODBUS Master
■ 1 x KNX (EIB) ■ 1 x MODBUS Slave
■ 1 x M-Bus ■ 1 x DMX

Note: A sufficient number of external COM interfaces* must be availab-


le when planning the simultaneous use of several protocols.

OPEN 4100 EMS OPEN 810 EMS OPEN 600 EMS

Native BACnet COM 5 - 8* Native BACnet Native BACnet

COM 5 -6*

COM 5 -6*
COM 2

COM 3

COM 2

COM 3

COM 2

COM 3
BACnet® MS/TP*** Service   ─   ─   ─
BACnet® PTP RS232  ─   ─   ─ 
KNX (EIB) Data points 50  ─   ─   ─ 
Data points 250  ─   ─  ─ ─ ─
Data points 500  ─   ─  ─ ─ ─
Data points 1000  ─   ─  ─ ─ ─
M-Bus Meters 10  ─   ─   ─ 
Meters 250  ─   ─  ─ ─ ─
MODBUS Slave         
MODBUS Master Data points 25         
Data points 50         
Data points 100         
Data points 250       ─ ─ ─
Data points 500       ─ ─ ─
Data points 1000       ─ ─ ─
ebm-papst Connection (7DP)         
Grundfos pumps Connection (7DP)         
*** max. up to 99 participants = Protocols possible ─ = not possible

Activation of options:
If an OPEN EMS is installed already and an upgrade at the installation has to be done which needs a change of the activated
options, so this activation could be done easily at the installation.
Therefore the Device Code of the device has to be send to us. This Device Code can be found on the Service-Page „Options“.
With the Device Code we will generate a new Activation Code which has to be entered at the Service-Page „Options“. This kind of
activation of additional options can be done with OPEN EMS remote activation. This is possible with OPEN EMS version 1.040 or
newer. The following options can be activated: EIB (KNX), M-Bus, MODBUS Master, MODBUS Slave and OPENview (Graphic).

C 2018 - Technical changes excepted. Pictured products similar. 21


Overview Controllers OPEN EMS

Equipment OPEN 3100 EMS OPEN 710 EMS OPEN 500 EMS

3100 3100 710/0 710/5 710/12 710/32 500/0 500/5


C1 C2 500H/0 500H/5

COM 1 Service ■ ■ ■ ■ ■ ■ ■ ■
COM 2 RS232 ■ ■ ■ ■ ■ ■ ■ ■
COM3 RS485 ■ ■ ■ ■ ■ ■ ■ ■
CAN 1 max. devices** 100 100 8 10 25 50 8 10
OPEN IO module/PWH/PLD 99 99 ─ 5 12 32 ─ 5
Control unit LSD-C 30 30 2 2 2 10 2 2
IO7 / GALAXY / CORA / CODI 96 96 5 5 12 32 5 5
CAN 2 max. devices** ─ 100 ─ ─ ─ ─ ─ ─
OPEN IO module/PWH/PLD ─ 99 ─ ─ ─ ─ ─ ─
Control unit LSD-C ─ 30 ─ ─ ─ ─ ─ ─
IO7 / GALAXY / CORA / CODI ─ 96 ─ ─ ─ ─ ─ ─
Multi-protocol
Ethernet 4 4 4 4 4 4 4 4
(OPENweb Server)
external COM Interfaces*
4 4 2 2 2 2 2 2
(free)
OPENview text-based webserver ■ ■ ■ ■ ■ ■ ■ ■
graphical webserver □ □ □ □ □ □ □ □
M-Bus 250 250 250 250 250 250 10 10
KNXnet/IP max. 50 Data points ─ ─ ─ ─ ─ ─ □ □
max. 1000 Data points □ □ □ □ □ □ ─ ─
CAN-HSB ─ ■ ─ ─ ─ ─ ─ ─
OPENdynamics □ □ □ □ □ □ □ □

■ = Standard □ = Optional ─ = not available


** max. number of all devices incl. controller at one bus

* External serial interfaces

Via external TCP/IP Controller (page 110) additional serial interfaces can be connected to one
OPEN EMS. Depending on the version of the TCP/IP controller they can be accomplished as RS232 or RS485.

The OPEN 4100 EMS can be extended with 4 additonal external serial interfaces (COM 5 .. COM 8).
The OPEN 810 EMS and OPEN 600 EMS can be extended with 2 additonal external serial interfaces (COM 5 and COM 6).

22 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN EMS Overview Controllers

Available protocols Supported protocols


The freely usable interfaces COM 2 (RS232) and COM 3 (RS485), as
for COM interfaces well as the optional external COM interfaces* offer the possibility for
(Connectivity) the connection of the following protocols to the OPEN EMS.

via RS232 via RS485


■ 2 x Modem ■ 1 x MODBUS Master
■ 1 x Multi-protocol ■ 1 x MODBUS Slave
■ 1 x KNX (EIB) ■ 1 x DMX

■ 1 x M-Bus

Note: A sufficient number of external COM interfaces* must be availab-


le when planning the simultaneous use of several protocols.

OPEN 3100 EMS COM 5 - 8* OPEN 710 EMS OPEN 500 EMS

COM 5 -6*

COM 5 -6*
COM 2

COM 3

COM 2

COM 3

COM 2

COM 3
KNX (EIB) Data points 50  ─   ─   ─ 
Data points 250  ─   ─  ─ ─ ─
Data points 500  ─   ─  ─ ─ ─
Data points 1000  ─   ─  ─ ─ ─
M-Bus Meter 10  ─   ─   ─ 
Meter 250  ─   ─  ─ ─ ─
MODBUS Slave         
MODBUS Master Data points 25         
Data points 50         
Data points 100         
Data points 250       ─ ─ ─
Data points 500       ─ ─ ─
Data points 1000       ─ ─ ─
ebm-papst Connection (7DP)         
Grundfos pumps Connection (7DP)         
= Protocols possible ─ = not possible

Activation of options:
If an OPEN EMS is installed already and an upgrade at the installation has to be done which needs a change of the activated
options, so this activation could be done easily at the installation.
Therefore the Device Code of the device has to be send to us. This Device Code can be found on the Service-Page „Options“.
With the Device Code we will generate a new Activation Code which has to be entered at the Service-Page „Options“. This kind
of activation of additional options can be done with OPEN EMS remote activation. This is possible with OPEN EMS version
1.040 or newer.
The following options can be activated: EIB (KNX), M-Bus, MODBUS Master, MODBUS Slave and OPENview (Graphic).

C 2018 - Technical changes excepted. Pictured products similar. 23


Overview Controllers OPEN EMS

Equipment OPEN 810 EMS + DALI OPEN 710 EMS + DALI

with DALI interface Native BACnet

810/0 810/5 810/12 810/32 710/0 710/5 710/12 710/32

1 x DALI interface DALI adresses 64 64 64 64 64 64 64 64


2 x DALI interface DALI adresses 128 128 128 128 128 128 128 128
3 x DALI interface DALI adresses 192 192 192 192 192 192 192 192
4 x DALI interface DALI adresses 256 256 256 256 256 256 256 256

Note:
• Every OPEN EMS with DALI interface has got indentical technical characteristics like the OPEN EMS of the same type without
DALI interface. All possible protocols are the same.
• There is no possibility of retrofitting the DALI interface on an existing OPEN EMS without DALI interface.
• At least, you have to order the activation for one DALI interface on an OPEN EMS + DALI. An enlargement from 1 up to 4 DALI
interfaces may be realized via device code software.

Equipment OPEN 810 EMS + M-Bus OPEN 710 EMS + M-Bus

with integrated Native BACnet

M-Bus interface 810/0 810/5 810/12 810/32 710/0 710/5 710/12 710/32

M-Bus interfaces 2 2 2 2 2 2 2 2
M-Bus meters max. 120 120 120 120 120 120 120 120

Note:
• Every OPEN EMS with M-Bus interface has got indentical technical characteristics like the OPEN EMS of the same type
without integrated M-Bus interface. All possible protocols are the same.
• There is no possibility of retrofitting the M-Bus interface on an existing OPEN EMS without integrated M-Bus interface.
• For connecting up to 120 M-Bus meters on these controllers there is no need for additional external level converters.
Up to 60 M-Bus meters can be connected to every M-Bus interface.

24 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN EMS Hot Standby Controllers (Redundancy)

Description

OPEN 4100 EMS as redundant version.

For a maximum operational safety, the OPEN 4100 EMS can be operated as a redundant
system.
For this solution, two controllers are operated at one CAN-bus. The first controller (Primary)
normally handles all monitoring and control functions.
The second controller (Secondary) is in a hot standby mode. If the Primary controller breaks
down, the Secondary controller will automatically take over all monitoring and control functions,
with no downtime. The option ‘Redundancy’ must be activated for both controllers.

Functions:
• Automatic cyclic imaging of all variables (incl. intermediate results) from the Primary controller
to the standby controller (Secondary).
• Automatic switching from the active controller (Primary) to the standby controller (Secondary),
in case the Primary controller malfunctions or breaks down.
• The standby controller takes over all functions nearly “on-line”.
• Both controllers are operated at one CAN-bus. No physical switching of the CAN-bus is requi-
red.
• There won´t be any impact on the current operating status of the complete control system
(e.g. control and follow-on signals, timer programs, etc.).
• Changes of the timer programs, parameters and set-points at the active controller are auto-
matically transferred to the standby controller.
• A Breakdown of the standby controller will be reported to the BMS if the standby controller is
“not active”.
• Within the BMS, the operational system will be displayed in only one system overview.
• If the Primary controller is not active anymore and the secondary controller has taken over,
this situation will be displayed in the system overview graph (important error message, imme-
diate action required).

Note:
The option ”Redundancy” is possible only with the OPEN 4100 EMS.
For a redundant system 2 controllers are necessary.

Article Type Art.-No.


OPEN 4100 EMS
Hot Standby Controller DS-4100 OPEN C1/R DS-360095
like OPEN 4100 EMS C1,
but as redundant system
Hot Standby Controller DS-4100 OPEN C2/R DS-360096
like OPEN 4100 EMS C2,
but as redundant system

C 2018 - Technical changes excepted. Pictured products similar. 25


CAN-HSB High Safety Bus OPEN EMS

Description

CAN-HSB High Safety Bus

With the CAN-HSB (High Safety Bus), DEOS AG offers the next step
of the worldwide approved CAN-bus.

For the safe operation of CAN-HSB, both CAN-interfaces of an OPEN


3100 EMS C2 or an OPEN 4100 EMS C2 are used. For these cont-
rollers the following two operating modes are available from firmware
version 1.050 onwards. They can be individually activated by service
technicians:

• Standard mode: both CAN-bus interfaces are used independently.

• CAN-HSB mode: both CAN-bus interfaces are integrated in the


safety ring.

The CAN-HSB extends the function- and diagnostic abilities of a


standard CAN-bus and offers additional security features. In case of a
broken CAN-bus a diagnostic process runs to localize the cause of the
failure easily. In case an interruption occurs, the complete CAN-bus
remains fully operational due to the redundant access.
To support a fast and easy repair of the interruption, the communica-
tion is logged and a detailed report shows which IO modules are still
addressable.

In standard mode up to 99 OPEN IO modules can be connected to a


CAN-HSB at the same time. A modification of the control program is
not necessary for using HSB.

By functional program modules, which are especially designed for the


CAN-HSB, additional status information of the current operating status
are provided and evaluated. Due to this permanent online monitoring,
the high availability of the bus-communication is achieved.

CAN C1 + CAN C2 = CAN-HSB up to 5 km

C2 CAN

C1 CAN

OPEN 4100 C2 IO modules IO module IO module

IO 7-B IO 7-B IO 7

PLDx-24-CAN PWDx-24-CAN PWHx-24Y-C

26 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules
OPEN IO Modules Page OPEN IO Modules Page
C-DI16 28 PKM - coupler module 40
C-DI8DO8T 29 Accessories OPEN IO module 41
C-DO8T 30 MT-R 42
C-DO8TH 31 EPLAN Macros 43
C-DO8R 32 IO7-B 44
C-DO8RH 33 IO7 45
C-AI8 35
C-AI8AO4 36
C-AI8AO4H 37
C-AO4 38
C-AO4H 39

C 2018 - Technical changes excepted. Pictured products similar. 27


C-DI16 OPEN IO Modules

Description Wiring diagram


Digital Input module for mounting on 35 mm DIN
rail. The 45 mm automat profile module is also
suitable for the installation in distribution or con-
trol cabinets etc.. Control via CAN-bus in combi-
nation with an OPEN EMS.

• 16 reporting / counting inputs 24 V DC,


optically decoupled, with LEDs
• LED color of the inputs red / green
programmable
• Pulse rate up to 80 Hz
• removable spring terminals up to 1.5 mm²

• Supply voltage: 24 V DC
• Current consumption: 50 mA
• CAN-bus: CAN 2.0B, electrically isolated ISO
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s CAUTION !! Free terminals must not be used as connecting terminals.

Note:
Up to 15 modules in one row may be connected via the bus connector.
Beyond 15 modules, a further external power supply must be provided.

Article Type Art.-No.


OPEN IO module DS-C-DI16 DS-390036
digital input module
16 digital inputs
LED color red / green programmable

28 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules C-DI8DO8T

Description Wiring diagram


Digital Multi IO module for mounting on 35 mm
DIN rail. The 45 mm automat profile module
is also suitable for installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• Inputs:
• 8 reporting / counting inputs 24 V DC, optically
decoupled, with LEDs
• LED color of the inputs red / green
programmable
• Pulse rate up to 80 Hz
• Outputs:
• 8 transistor outputs, 24 V DC 80 mA
• Short-circuit proof, electrically isolated
• 8 LEDs for operating status
• removable spring terminals up to 1.5 mm²
CAUTION !! Free terminals must not be used as connecting terminals.
• Supply voltage: 24 V DC
• Current consumption: approx. 50 mA plus sup- Note:
Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
ply of connected units les, a further external power supply must be provided.
• CAN-bus: CAN 2.0B, electrically isolated ISO
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s

Article Type Art.-No.


OPEN IO module DS-C-DI8DO8T DS-390035
digital multi IO module
8 digital inputs
8 digital outputs (transistor outputs)
w/o manual control

C 2018 - Technical changes excepted. Pictured products similar. 29


C-DO8T OPEN IO Modules

Description Wiring diagram


Digital output module for mounting on 35 mm
DIN rail. The 45 mm automat profile module is
also suitable for the installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• 8 transistor outputs,
24 V DC 80 mA
• Short-circuit proof, electrically isolated
• 8 LEDs for operating status
• removable spring terminals up to 1.5 mm²

• Supply voltage: 24 V DC
• Current consumption: 50 mA,
plus supply of connected units.
• CAN-bus: CAN 2.0B, electrically isolated ISO
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s CAUTION !! Free terminals must not be used as connecting terminals.

Note:
Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
les, a further external power supply must be provided.

Article Type Art.-No.


OPEN IO module DS-C-DO8T DS-390041
digital output module
8 digital outputs (transistor outputs)
w/o manual control

30 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules C-DO8TH

Description Wiring diagram


Digital output module with manual override swit-
ches acc. to VDI 3814 page 1 for mounting on 35
mm DIN rail. The 45 mm automat profile module
is also suitable for the installation in distribution
or control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• 8 transistor outputs
24 V DC 80 mA
• short-circuit proof, electrically isolated
• 8 LEDs for operating status
• Manual control for each output
• removable spring terminals up to 1.5 mm²

• Voltage supply: 24 V DC
• Current consumption: approx. 50 mA,
plus supply of connected units.
• CAN-bus: CAN 2.0B, electrically isolated ISO CAUTION !! Free terminals must not be used as connecting terminals.
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s Note:
Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
les, a further external power supply must be provided.

Article Type Art.-No.


OPEN IO module DS-C-DO8TH DS-390042
digital output module
8 digital outputs (transistor outputs)
manual control with toggle switch

C 2018 - Technical changes excepted. Pictured products similar. 31


C-DO8R OPEN IO Modules

Description Wiring diagram

Digital output module for mounting on 35 mm


DIN rail. The 45 mm automat profile module is
also suitable for the installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• 8 relay outputs
• 4 change-over contacts
• 4 make contacts
• 8 LEDs for operating status
• removable spring terminals up to 1.5 mm²

• Supply voltage: 24 V DC
• Current consumption: 100 mA
• CAN-bus: CAN 2.0B, electrically isolated ISO CAUTION !! Free terminals must not be used as connecting terminals.
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
Note:
50 kbit/s Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
les, a further external power supply must be provided.

Note:
Max. load of output contacts
230 V AC; 3.0 A /AC1*
230 V AC; 0.8 A / AC15*
30V DC; 3 A / DC1*
230 V DC; 0.1 / A DC1*
pre-fuse: max. 6 A
max. 10 A each module

Article Type Art.-No.


OPEN IO module DS-C-DO8R DS-390038
digital output modules
8 digital outputs (relay outputs)
w/o manual control

* AC1 = resistive load


AC15 = monitoring of electro-magnetic load, aux. current switches, power contactors, solenoid valves and electro-magnets
DC1 = resistive load. Non inductive or only low inductive load.

32 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules C-DO8RH

Description Wiring diagram


Digital output module with manual override swit-
ches acc. to VDI 3814 page 1 for mounting on 35
mm DIN rail. The 45 mm automat profile module
is also suitable for installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• 8 relay outputs
• 4 change-over contacts
• 4 make contacts
• 8 LEDs for operating status
• Manual control for each output
• removable spring terminals up to 1.5 mm²

• Voltage supply: 24 V DC
• Current consumption: 100 mA CAUTION !! Free terminals must not be used as connecting terminals.
• CAN-bus: CAN 2.0B, electrically isolated ISO
Note:
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
50 kbit/s les, a further external power supply must be provided.

Note:
Max. load of output contacts
230 V AC; 3.0 A /AC1*
230 V AC; 0.8 A / AC15*
30V DC; 3 A / DC1*
230 V DC; 0.1 / A DC1*
pre-fuse: max. 6 A
max. 10 A each module

Article Type Art.-No.


OPEN IO module DS-C-DO8RH DS-390039
digital output module
8 digital outputs (relay outputs)
manual control with toggle switch
digital output module DS-C-DO8RH/S DS-390040
8 digital outputs (relay outputs)
manual control with switches

* AC1 = resistive load


AC15 = monitoring of electro-magnetic load, aux. current switches, power contactors, solenoid valves and electro-magnets
DC1 = resistive load. Non inductive or only low inductive load.

C 2018 - Technical changes excepted. Pictured products similar. 33


Notice

34 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules C-AI8

Description Wiring diagram


Analog input module for mounting on 35 mm
DIN rail. The 45 mm automat profile module is
also suitable for the installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• 8 analog inputs for sensors


with measuring elements
• LM (10 mV/K)
• Pt1000
• Ni1000 DIN
• Ni1000 TK5000
• Potentiometer
• 0 .. 10 V DC
• 0 .. 20 mA
(with external 500 Ohm resitor)
• removable spring terminals up to 1.5 mm²

• Supply voltage: 24 V DC
• Current consumption: 100 mA CAUTION !! Free terminals must not be used as connecting terminals.
• CAN-bus: CAN 2.0B, electrically isolated ISO Note:
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
50 kbit/s les, a further external power supply must be provided.

Article Type Art.-No.


OPEN IO module DS-C-AI8 DS-390037
analog input module
8 analog inputs
w/o manual control

C 2018 - Technical changes excepted. Pictured products similar. 35


C-AI8AO4 OPEN IO Modules

Description Wiring diagram


Analog IO module for mounting on 35 mm DIN
rail. The 45 mm automat profile module is also
suitable for the installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• 8 analog inputs for sensors


with measuring elements
• LM (10 mV/K)
• Pt1000
• Ni1000 DIN
• Ni1000 TK5000
• Potentiometer
• 0 .. 10 V DC
• 0 .. 20 mA
(with external 500 Ohm resitor)
• 4 analog outputs 0 .. 10 V / 8 mA,
short-circuit proof
• removable spring terminals up to 1.5 mm²
CAUTION !! Free terminals must not be used as connecting terminals.
• Supply voltage: 24 V DC Note:
• Current consumption: approx. 100 mA Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
• CAN-bus: CAN 2.0B, electrically isolated ISO les, a further external power supply must be provided.
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s

Article Type Art.-No.


OPEN IO module DS-C-AI8AO4 DS-390045
analog IO module
8 analog inputs
4 analog outputs
w/o manual control

36 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules C-AI8AO4H

Description Wiring diagram


Analog IO module with manual override switches
acc. to VDI 3814 page 1 for mounting on 35 mm
DIN rail. The 45 mm automat profile module is
also suitable for the installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with an OPEN EMS.

• 8 analog inputs for sensors


with measuring elements
• LM (10 mV/K)
• Pt1000
• Ni1000 DIN
• Ni1000 TK5000
• Potentiometer
• 0 .. 10 V DC
• 0 .. 20 mA
(with externeal 500 Ohm resitor)
• 4 analog outputs 0 .. 10 V / 8 mA,
short-circuit proof
• Manual control for each output CAUTION !! Free terminals must not be used as connecting terminals.
• removable spring terminals up to 1.5 mm² Note:
Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
• Supply voltage: 24 V DC les, a further external power supply must be provided.
• Current consumption: approx. 100 mA
• CAN-bus: CAN 2.0B, electrically isolated ISO
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s
Article Type Art.-No.
OPEN IO module DS-C-AI8AO4H DS-390046
analog IO module
8 analog inputs
4 analog outputs
manual control with toggle switch

C 2018 - Technical changes excepted. Pictured products similar. 37


C-AO4 OPEN IO Modules

Description Wiring diagram


Analog output module for mounting on 35 mm
DIN rail. The 45 mm automat profile module is
also suitable the for installation in distribution or
control cabinets, etc.. Control via CAN-bus in
combination with OPEN EMS.

• 4 analog outputs 0 .. 10 V / 8mA


short-circuit proof
• removable spring terminals up to 1.5 mm²

• Supply voltage: 24 V DC
• Current consumption: 100 mA
• CAN-bus: CAN 2.0B, electrically isolated ISO
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s

CAUTION !! Free terminals must not be used as connecting terminals.

Note:
Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
les, a further external power supply must be provided.

Article Type Art.-No.


OPEN IO module DS-C-AO4 DS-390043
analog output module
4 analog outputs
w/o manual control

38 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules C-AO4H

Description Wiring diagram


Analog output module with manual override swit-
ches acc. to VDI 3814 page 1 for mounting on 35
mm DIN rail. The 45 mm automat profile module
is also suitable for the installation in distribution
or control cabinets, etc.. Control via CAN-bus in
combination with OPEN EMS.

• 4 analog outputs 0 .. 10 V / 8 mA,


short-circuit proof
• Manual control for each output
• removable spring terminals up to 1.5 mm²

• Supply voltage: 24 V DC
• Current consumption: approx. 100 mA
• CAN-bus: CAN 2.0B, electrically isolated ISO
11898, Baud rate: 10 kbit/s .. 1 Mbit/s, preset to
50 kbit/s

CAUTION !! Free terminals must not be used as connecting terminals.

Note:
Up to 15 modules in one row may be connected via the bus connector. Beyond 15 modu-
les, a further external power supply must be provided.

Article Type Art.-No.


OPEN IO module DS-C-AO4H DS-390044
analog output module
4 analog outputs
manual control with toggle switch

C 2018 - Technical changes excepted. Pictured products similar. 39


PKM OPEN IO Modules

Description Wiring diagram


At the start of a module series, the coupler
module DS-PKM is used to feed the 24 V DC
supply voltage and the CAN bus. At the end
of the module series, it provides access to the
CAN-bus. Here, a new module series can be
connected. Each coupler module can be used for
both feeding and connecting functions.

The 45 mm automat profile module is also sui-


table for the installation in distribution or control
cabinets etc..

The coupler module also features a terminating


resistor for the CAN-bus. The termination can be
switched on or off via a small slide switch on the
top of the module.

CAUTION !!
Free terminals must not be used as connecting terminals.

Article Type Art.-No.


OPEN Coupler module DS-PKM DS-390024
Coupler module for feeding of supply voltage
and CAN-bus for OPEN IO modules with
integrated bus terminating resistor.
Delivery: 1 piece DS-PKM

Delivery: 2 pieces DS-PKM DS-PKM -2x- DS-390022

40 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules Accessories

Article Type Art.-No.


Bridge bus connector DS-BBS 10 DS-390019
for OPEN IO modules

Package: 10 pcs.

Bridge bus connector DS-BBS 100 DS-390020


for OPEN IO modules

Package: 100 pcs.


Wall mounting adapter for housing module DS-WH DS-350126

Wall mounting adapter for a free installation of module-


housings, for example for OPEN IO modules. Suitable for
module-housings with a width of 53 / 106 and 160 mm.

Label carrier DS-ET31,5 DS-350045


to hold OPEN IO module designations prepared on
Zweckform labels No. 3657 or No. 4780.

Size: Cover width  31,5 mm


max. label width  29,0 mm
Depth  5,6 mm
Length  1000,0 mm
Material: Base, Hard-PVC grey (RAL 7030)
Cover, Hard-PVC clear
Fixing:
• screws
• adhesive
• at cable duct
using mounting base DS-PES
Mounting base DS-PES DS-350046
for label carrier DS- ET31,5
for fixing at cable duct

Package: 25 pcs.

Installation examples:

Fixing of label carrier using mounting base DS-PES


at cable duct cover

Fixing of label carrier using adhesive


tape at cable duct cover

C 2018 - Technical changes excepted. Pictured products similar. 41


MT-R OPEN IO Modules

Description Wiring diagram


By using an MT-R, the measuring range for resis-
tance sensors of an IO module can be extended
significantly.

Also resistance sensors with larger measuring


ranges can be connected easily. NTC and PTC
sensors accept resistance values of approx. 200
Ohm up to 1 MOhm.

With a measurement-transformation-module for


resistors (MT-R), these sensors can be easily
connected to the analog inputs of the IO modules
or to the integrated analog inputs of the
OPEN EMS.

The measurement converter MT-R has 8 analog


in- and outputs, so up to 8 PTC / NTC sensors
can be connected to one module.

Article Type Art.-No.


OPEN MT-R DS-MT-R DS-390047
Measurement converter with 8 analog inputs
for the connection of PTC / NTC sensors.

42 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
EPLAN Macros Service

EPLAN Macro
Do you generate your circuit diagrams with EPLAN?
We make your work easier and provide you with an EPLAN macro for free, relating to our products
OPEN EMS and OPEN IO modules.

The macros reflect our longtime experience in plant engineering and our know-how in building
automation.

Please send us an e-mail (info@deos-ag.com) to receive the following macros.


They are available for EPLAN Electric P8 (version 1.9) on:

OPEN Controller OPEN IO module


OPEN 4100 EMS C-DI16
OPEN 3100 EMS C-DI8DO8T
OPEN 810 EMS C-DO8T
OPEN 710 EMS C-DO8TH
OPEN 600H/5 EMS C-DO8R
OPEN 600H/0 EMS C-DO8RH
OPEN 600/5 EMS C-DO8RH/S
OPEN 600/0 EMS C-AI8
OPEN 500H/5 EMS C-AI8AO4
OPEN 500H/0 EMS C-AI8AO4H
OPEN 500/5 EMS C-AO4
OPEN 500/0 EMS C-AO4H

DEOS Item Library for WSCAD


In cooperation with WSCAD, we are now offering our product data for the OPEN EMS platform, with the corresponding
electrical engineering item data.

You can find comprehensive DEOS product symbols at www.wscaduniverse.com in the data library for WSCAD and
EPLAN users.

WSCAD/DEOS offers additional advantages in programming DEOS controllers (OPEN EMS): by using the WSCAD
function to export I/O lists and import them into the DEOS programming and planning tool FUP XL 2, the input and
outputs are automatically created and assigned without disrupting any media.

Note:
The created plan can then also be exported for documentation purposes in formats offered by third-party ECAD sys-
tems.

C 2018 - Technical changes excepted. Pictured products similar. 43


IO7-B OPEN IO Modules

Description Technical Data


OPEN IO7-B is designed for the use with the Inputs
control system OPEN in office buildings, hotels, • 1 internal temperature sensor 0 .. 50 °C
administration centres, etc.. • 3 inputs, digital; (status inputs) 24 V DC, input resistance > 3.3 kOhm
• 1 input, analog; 0 ... 50 °C for sensors with measuring element LM
OPEN IO7-B features control buttons, LED and • 1 integrated control button in the housing
potentiometer. • 1 integrated potentiometer in the housing

Connection of the modules to the controller Outputs


via CAN-bus, standard transmission • 1 output, analog 0 ... 10 V, max. load 8 mA
rate: 50 kBit/s. • 2 universal outputs,
0 ... 10 V (active, max. 8 mA)
Supply voltage: 24 V DC 24 V digital (active, max. 800 mA),
Current consumption: 50 mA 24 V PWM (10 sec. period; active, max. 800 mA)
plus power consumption of the connected units. • 1 integrated LED in the housing

Dimensions: 84 mm x 84 mm x 28 mm
Dimensions
base plate

Article Type Art.-No.


OPEN IO module DS-IO7-B DS-390012

for wall mounting


with manual control

44 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN IO Modules IO7

Description Technical Data


OPEN IO7 is designed for the use with with the Inputs
control system OPEN in office buildings, hotels, • 1 internal temperature sensor 0 .. 50 °C
administration centres, etc.. • 3 inputs, digital; (status inputs) 24 V DC, input resistance > 3.3 kOhm
• 1 input, analog; 0 .. 50 °C for sensors with measuring element LM
Connection of the modules to the controller
via CAN-bus, standard transmission Outputs
rate: 50 kBit/s. • 1 output, analog 0 .. 10 V, max. load 8 mA
• 2 universal outputs, 0 .. 10 V (active, max. 8 mA)
Supply voltage: 24 V DC 24 V digital (active, max. 800 mA),
Current consumption: approx. 50 mA 24 V PWM (10 sec. period; active, max. 800 mA)
plus power consumption from the connected
units.

Dimensions: 84 mm x 84 mm x 28 mm

Dimensions
base plate

Articlel Type Art.-No.


OPEN IO module DS-IO7 DS-390013

for wall mounting


w/o manual control

C 2018 - Technical changes excepted. Pictured products similar. 45


Notice

46 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
Single Room Unit
OPEN SRU - BACnet® Single Room Unit Page
OPEN SRU 48
OPEN SRU + 4DO 50
OPEN SRU + KNX 51

OPEN SRU + 4R2T 52


OPEN SRU + MOD 53
SRU programming adapter 54

C 2018 - Technical changes excepted. Pictured products similar. 47


SRU BACnet® MS/TP Single Room Unit

Description Technical Data

The OPEN SRU single room unit is a Native BACnet Housing


controller and free programmable. OPEN SRU supports Dimensions (WxHxD) 106 mm x 90 (98) mm x 60 mm
the BACnet protocol acc. to ANSI/ASHRAE standard. Material plastic
The OPEN SRU single room unit is equipped with a Mounting on standard mounting rail 35 mm
BACnet MS/TP interface and can be connected to any Protection class IP 20
BACnet controller or a BACnet BMS via Cooling fanless by convection
BACnet MS/TP. Temperature range 0 ..50 °C
Adress-switch for adjustment of the Bus-address
The operational areas of the OPEN SRU are various. In LED for operating display
particular the OPEN SRU can be used for fan-coil- and LED for displaying the BUS condition
room air cascade controls, heating and cooling cascades DIP-switch for application-specific parameters
as well as for simple heating element controls. Thus Programming connector
the single room units are suitable for all kinds of HVAC Power supply
controls. Furthermore they can be used for light and Input voltage U(typ.) = 24 V DC (18 .. 30 V DC),
shutter controls. 24 V AC +/- 10%
As room control units, all conventional devices can be Input current I(typ.) = approx. 80 mA
connected with or without button, setpoint and digital Power consumption approx. 2 W
displays. In addition, bus compatible control devices can Connection removable spring terminals
be used in all versions. Cross section 1,5 mm²
The OPEN SRU has 8 universal inputs, Micro processor and memory
4 universal outputs and 4 digital outputs - 2 digital CPU ARM7 Architecture
ouptus are designed as a high current outputs. Interfaces
1x RS485 native BACnet MS/TP,
To the analog inputs, sensors can be connected directly galvanic isolated,
with the measuring elements 10 mV/K, Pt1000, Ni1000 spring terminals up to 1,5 mm²
DIN and Ni1000 TK5000. 1x CAN Local for connection of a control device:
GALAXY / CORA

Article Type Art.-No.


BACnet single room unit OPEN SRU DS-SRU DS-340003
standard with 8 universal inputs, 4 universal outputs
and 4 digital outputs.

Note: For high quantities, special prices will be offered.

48 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
BACnet® MS/TP Single Room Unit SRU

In / Outputs:
8 Universal Inputs
• Operation as digital input:
• 24 V DC
• Input resistance Rin = approx.. 100 kΩ against GND
• State input, debouncing: dependent on the operation mode
• Button, debouncing: dependent on the operation mode
• Counter up to 1 Hz (Software)
2x counter up to 80 Hz, input resistance Rin = approx. 5 kΩ against GND
Input 0 + 1 applicable as fast counters.
• Operation as analog input:
• 0-10 V resolution 12 mV
• 10 mV/K Meas. range 0 .. +50 °C, resolution 0,07 K
• Pt1000 Meas. range 0 .. +50 °C, resolution 0,11 K
• Ni1000 DIN Meas. range 0 .. +50 °C, resolution 0,08 K
• Ni1000 TK5000 Meas. range 0 .. +50 °C, resolution 0,1 K
• Poti Meas. range 0,5 .. 10 kΩ, resolution 15 Ω
4 Universal Outputs
• Selectable operation as analog- or digital output
• Short-circuit-proof
• Operation as digital output
• 24 V DC (at 24 V AC supply - ripple is load-dependent)
• Output condition, debouncing: dependent on the operation mode
• Pulse-output (Software)
• PWM-output (Software)
• Loadable up to max. 80 mA
• Operation as analog-output
• 0-10 V
• Loadable up to max. 8 mA
2 Digital-Outputs
• 24 V DC (at 24 V AC supply - ripple is load-dependent)
• Short-circuit-proof
• Output-condition
• Pulse-Output (Software)
• PWM-Output (Software)
• Loadable up to max. 80 mA
2 Digital-Outputs (High Current)
• 24 V DC or 24 V AC - the signal form corresponds to the supply voltage
• Output-condition
• Pulse-Output (Software)
• PWM-Output (Software)
• Loadable up to max. 800 mA

C 2018 - Technical changes excepted. Pictured products similar. 49


SRU+4DO BACnet® MS/TP Single Room Unit

Description Technical Data


The OPEN SRU single room unit in the variant Technical data such as standard version type: DS-SRU
DS-SRU+4DO is designed as a Native BACnet but with additional option board 4DO (4 digital outputs),
controller and free programmable. total of 20 IOs.
OPEN SRU supports the BACnet protocol acc.
to ANSI/ASHRAE standard. additional digital outputs:
The OPEN SRU single room unit is equipped with
a BACnet MS/TP interface and can be connected 2x Digital-Outputs
to any BACnet controller or a BACnet BMS via • 24 V DC (at 24 V AC supply
BACnet MS/TP. ripple load dependent)
• Short-circuit-proof
This device and the properties of the In- and Out- • state output
puts correspond to the data of the OPEN SRU in • Pulse- Output (Software)
the base variant (DS-SRU). • PWM-Output(Software)
• Loadable up to max. 80 mA
In this variant of the single room unit four addi- 2x Digital-Outputs (High Current)
tional digital outputs are available. Two outputs • 24 V DC or 24 V AC - the signal form
are designed as standard digital outputs (80 mA) corresponds to the supply voltage
and two outputs are designed for high switching • Output-condition
loads. These can each be loaded with up to 800 • Pulse-Output (Software)
mA. • PWM-Output (Software)
• Loadable up to max. 800 mA
To the analog inputs, sensors can be connected
directly with the measuring elements 10 mV/K,
Pt1000, Ni1000 DIN and Ni1000 TK5000.

Article Type Art.-No.


BACnet single room unit OPEN SRU DS-SRU+4DO DS-340004
as standard, with additional expansion option 4DO
4DO = 2 digital outputs and 2 digital outputs 800 mA.

Note: For high quantities, special prices will be offered.

50 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
BACnet® MS/TP Single Room Unit SRU+KNX

Description Technical Information


The OPEN SRU single room unit in the variant The In- and Outputs as well as the technical data correspond
DS-SRU+KNX is designed as a Native BACnet to the standard version Type: DS-SRU.
controller and free programmable.
OPEN SRU supports the BACnet protocol acc. to Additionally the controller is equipped with a KNX (EIB) interface:
ANSI/ASHRAE standard. Up to 50 KNX communication objects can be processed.
The OPEN SRU single room unit is equipped with
a BACnet MS/TP interface and can be connected The following KNX data types are supported:
to any BACnet controller or a BACnet BMS via
BACnet MS/TP. • EIS1 (Dpt 1.*)
• EIS5 (Dpt 9.*)
This device and the properties of the In- and Out- • EIS6 (Dpt 5.*)
puts correspond to the data of the OPEN SRU in • EIS9 (Dpt 14.*)
the base variant (DS-SRU). • EIS10 (Dpt 7.*)
• EIS11 (Dpt 12.*)
In the variant +KNX the single room unit is additi-
onally equipped with a KNX (EIB) interface.
With this option, KNX sensors and actuators can
be controlled directly by the SRU. Featuring a
local direct KNX interface, this unit enables the
use of the large variety of functions and designs
of KNX devices offered by a large number of third
party vendors.

To the analog inputs, sensors can be connected


directly with the measuring elements 10 mV/K,
Pt1000, Ni1000 DIN and Ni1000 TK5000.

Article Type Art.-No.


BACnet single room unit OPEN SRU DS-SRU+KNX DS-340007
as standard, with KNX (EIB) interface.

Note: For high quantities, special prices will be offered.

C 2018 - Technical changes excepted. Pictured products similar. 51


SRU+MODBUS BACnet® MS/TP Single Room Unit

Description Technical Information


The OPEN SRU single room unit in the variant The In- and Outputs as well as the technical data correspond
DS-SRU+MOD is designed as a Native BACnet to the standard version Type: DS-SRU.
controller and free programmable.
OPEN SRU supports the BACnet protocol acc. to Additionally the controller is equipped with a MODBUS interface:
ANSI/ASHRAE standard. Up to 50 KNX communication objects can be processed.
The OPEN SRU single room unit is equipped with
a BACnet MS/TP interface and can be connected
to any BACnet controller or a BACnet BMS via
BACnet MS/TP.

This device and the properties of the In- and Out-


puts correspond to the data of the OPEN SRU in
the base variant (DS-SRU).

In the variant +MOD the single room unit is additi-


onally equipped with a MODBUS interface.
With this option, MODBUS sensors and actuators
can be controlled directly by the SRU. Featuring
a local direct KNX interface, this unit enables the
use of the large variety of functions and designs
of MODBUS devices offered by a large number of
third party vendors.

To the analog inputs, sensors can be connected


directly with the measuring elements 10 mV/K,
Pt1000, Ni1000 DIN and Ni1000 TK5000.

Article Type Art.-No.


BACnet single room unit OPEN SRU DS-SRU+MOD DS-340008
as standard, with MODBUS interface.

Note: For high quantities, special prices will be offered.

52 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
BACnet® MS/TP Single Room Unit SRU Prg1

Description Technical Data


The SRU programming adapter is used to load
the application software into the single room Housing
control system OPEN SRU.
• Dimensions (WxHxD)
79 mm x 118 mm x 24 mm
The SRU programming adapter is supplied with
• Material ABS plastic
all necessary connecting cables.
• Protection class
IP 20
• Cooling no fan ; by convection
Delivery:
• Temperature range
0 .. 50 °C
1 x SRU programming adapter
• Connection via enclosed connecting cable
1 x USB connecting cable
• USB connecting cable
1 x loading cable
• loading cable
• Display LEDs SRU Active
RxD
TxD
Power

Power supply
• Input voltage via enclosed USB cable

Interface
• USB-interface connection to the PC or Laptop
• SRU-interface connection to the OPEN SRU

Article Type Art.-No.


SRU programming adapter DS-SRU-Prg 1 DS-340006
for loading the application software.

C 2018 - Technical changes excepted. Pictured products similar. 53


Notes BACnet® MS/TP Single Room Unit

54 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
Busses and Protocols
Busses and Protocols Page
M-Bus 57
KNX (EIB) 58
MODBUS 59
ebm-papst fan connection 60
Grundfos pump 60
LON 60

C 2018 - Technical changes excepted. Pictured products similar. 55


Busses and Protocols OPEN EMS

Article Type Art.-No.


KNX IP Interface 731 KNX IP Interface 731 DS-360010
Interface between IP and KNX-Bus
• Power supply: From KNX Bus
• Bus connector for KNX BUS (red / black)
• LAN connector (RJ-45)
• Electrical safety: Protection IP 20
• Rail mounted device, 1 unit (18mm)

Gateway MODBUS TCP/IP / MODBUS RTU DS-MOD GW DS-3500168


Interface between MODBUS TCP/ IP and MODBUS RTU
• Power supply: 9 - 26 VDC
• 1x Ethernet Interface, RJ45
• 1x serial Interface RS485
• Electrical safety: Protection IP 20
• Rail mounted device, 1 unit (18mm)

M-Bus connection with OPEN EMS


with external level converter

For connection of M-Bus meters to the OPEN EMS one fitting,


free interface is required. In addition the following components
are required:

• 1 x M-Bus level converter for connection of


M-Bus meters to the OPEN EMS
• 1 x Connecting cable RJ45DK9DE for connection to COM 2
• 1 x Connecting cable DS-RS232mf1:1 serial for
connection via TCP/IP controller

Note:
Only one M-Bus level converter can be connected per M-Bus.
Only one M-Bus level converter can be connected to a
OPEN EMS.

Interface cable RS 232 DS-RJ45DK9DE DS-024081


OPEN EMS - peripheral unit
RJ45 plug on SUB-D 9-pinplug, length of 1,5 m
Application: Modem, M-Bus, ...

Connecting cable RS232 1:1 extension DS-RS232mf1:1 DS-024022


SUB-D 9-pin, socket on SUB-D 9-pin plug,
length of 1,8 m

56 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN EMS Busses and Protocols

Article Type Art.-No.


M-Bus without additional level converter
(internal level converter)

In addition to the M-Bus activation on an OPEN EMS,


on page 12 you can find our controllers with integrated M-Bus
hardware. On these controllers you may connect up to
120 M-Bus meters without using any additional level converter.

M-Bus activation on OPEN EMS controllers


with external level converter

In delivery status M-Bus is activated in maximal stage of


expansion on all OPEN EMS controllers.

OPEN 500 EMS and OPEN 600 EMS:


Activation for connection of maximum 10 M-Bus meters

OPEN 4100 / 3100 / 810 and 710 EMS:


Activation for connection of maximum 250 M-Bus meters

For the connection of M-Bus meters a M-Bus level converter


is needed.

M-Bus level converter


RS 232/M-Bus converter
for connecting on OPEN EMS
• System interface: RS 232
• End device interface: M-Bus

Note: Only one M-Bus level converter can be connected


per M-Bus. One M-Bus level converter can be
connected to a OPEN EMS.

M-Bus level converter - 3 meters DS-MBusH3 DS-024086


• Max. no. of end devices: 3
• Voltage supply: 24 V DC
M-Bus level converter - 20 meters DS-MBusH20 DS-024087
• Max. no. of end devices: 20
• Voltage supply: 24 V DC
M-Bus level converter - 60 meters DS-MBusH60 DS-024088
• Max. no. of end devices: 60
• Voltage supply: 24 V DC
M-Bus level converter - 250 meters DS-MBusH250 DS-024089
• Max. no. of end devices: 250
• Voltage supply: 42 V DC, incl. power supply

C 2018 - Technical changes excepted. Pictured products similar. 57


Busses and Protocols OPEN EMS

Article Type Art.-No.


EIB (KNX) connection to OPEN EMS

An EIB (KNX) connection on the OPEN EMS can be ensured


via a serial interface RS232 or via a network interface (KNX-
net/IP).

Additionally, the following components are required:

In case of EIB (KNX) via appropriate RS232


• 1 x EIB gateway (KNX gateway)
• 1 x connecting cable RJ45DK9PC for connection to COM 2
• 1 x software activation acc. to the type of the OPEN EMS.
You can find an overview of all possible OPEN options on
page 20-24.

In case of KNXnet/IP
• 1 x software activation acc. to the type of the OPEN EMS.
You can find an overview of all possible OPEN options on
page 20-24.

For connecting EIB (KNX) to an OPEN EMS via network


interface (KNXnet/IP) you do not need any additional free
interface. You can use the existing network interface of the
OPEN EMS. You may also connect other KNXnet/IP gateways
(tunnelling mode) existing in the network.

Note:
Software activation for an EIB connection must be ordered
along with the main order for an OPEN EMS.
EIB-Gateway (KNX-Gateway) DS-EIB-01 DS-350069
for DIN rail mounting, voltage supply 230 V AC,
for connection of EIB-bus to OPEN EMS

Note:
Only one EIB-Gateway can be connected to a OPEN EMS.
EIB (KNX) Software DS-OPEN EIB 50 DS-371198
additional software module for all OPEN EMS
for EIB-Software connection of 50 data points
EIB (KNX) Software DS-OPEN EIB 250 DS-371121
additional software module
OPEN 4100 / 3100 / 810 und 710 EMS
for EIB-Software connection of 250 data points
EIB (KNX) Software DS-OPEN EIB 500 DS-371197
additional software module
OPEN 4100 / 3100 / 810 und 710 EMS
for EIB-Software connection of 500 data points
EIB (KNX) Software DS-OPEN EIB 1000 DS-371123
additional software module
OPEN 4100 / 3100 / 810 und 710 EMS
for EIB-Software connection of 1000 data points
Connecting cable OPEN EMS DS-RJ45DK9PC DS-024082
Interface cable RS 232
OPEN EMS - PC
RJ45 plug on SUB-D 9-pin plug, length of 1.5 m
Application: Modem, M-Bus, ..., PC / Laptop

58 C 2018 - Technical changes excepted. Pictures similar.


Control Technology
OPEN EMS Busses and Protocols

Artikel Type Art.-No.


MODBUS connection to OPEN EMS

For connection of Modbus to the OPEN EMS one fitting, free


interface is required and an activation of the relevant option on
the OPEN EMS.
An overview of the possible OPEN options can be found on
page 20-24.

Note:
Software activation for a MODBUS connection must be orde-
red along with the main order for the OPEN EMS.

MODBUS connection DS-MOD SL DS-371169


• For the connection of OPEN EMS
to MODBUS-Master devices
• No limitation of data points
• The OPEN EMS is used as Modbus-Slave
• MODBUS RTU via RS 232 / RS485 and Modbus TCP
can be operated simultaneously

MODBUS connection
• For the connection of MODBUS-Slave devices
to all OPEN EMS
• MODBUS RTU supported via RS232 / RS485 and
MODBUS TCP. Simultaneous use of
MODBUS RTU and MODBUS TCP is not possible.
• For up to 25 data points DS-MOD MA 25 DS-371220

• For up to 50 data points DS-MOD MA 50 DS-371170

• For up to 100 data points NEU DS-MOD MA 100 DS-371264


NEW

MODBUS connection
• For the connection of MODBUS-Slave devices
to OPEN 4100 / 3100 / 810 und 710 EMS
• MODBUS RTU supported via RS232 / RS485 and
MODBUS TCP. Simultaneous use of
MODBUS RTU and MODBUS TCP is not possible.
• For up to 250 data points DS-MOD MA 250 DS-371171

• For up to 500 data points DS-MOD MA 500 DS-371194

• For up to 1000 data points DS-MOD MA 1000 DS-371195

C 2018 - Technical changes excepted. Pictured products similar. 59


Busses and Protocols OPEN EMS

Article Type Art.-No.


Connection of ebm-papst fans and Grundfos pumps via
RS 485 to OPEN EMS.

Note:
Both connections can not be operated simultaneously at a
OPEN EMS.

ebm-papst fan connection DS-EBM-PST DS-371206

Software module for connection of one ebm-papst fan


to a OPEN EMS.

Activation license (7DP) for 1 ebm-papst fan

Note:
Max. 128 ebm-papst fans can be connected via the RS485
interface.

Grundfos pump connection DS-GR-PU DS-371207

Software module for connection of one Grundfos pump


to a OPEN EMS.

Activation license (7DP) for 1 Grundfos pump

Note:
Max. 31 Grundfos pumps can be connected via the RS485
interface.

LON connection DS-LONBAC-950 DS-360109


Universal gateway to convert LON variables
to BACnet objects

• up to 1000 BACnet objects


• Device profile B-BC
• Interfaces 1 x TP/FT-10
1 x BACnet MS/TP
1 x Ethernet (IP-852 / BACnet/IP)
• Power supply 24 V AC / DC
typical 2,5W

60 C 2018 - Technical changes excepted. Pictures similar.


Efficiency solutions
Efficiency Solutions
Efficiency Solutions Seite
OPENdynamics 62
OPENapp HAVC 64
OPENapp HAVC Package Units 64

C 2018 - Technical changes excepted. Pictured products similar. 61


OPENdynamics Efficiency Solutions

Description
OPENdynamics is a control program that provides optimal OPENdynamics significantly reduces the supply of air vo-
climate management in buildings whilst minimizing the ener- lume flow, duct noise levels are also reduced and mainte-
gy consumption of air-handling systems. OPENdynamics nance costs kept to a minimum.
achieves this by utilizing patented technologies in order to
calculate the ideal values of damper positions, supply tem- OPENdynamics was developed as a set of macros which
peratures, humidity controllers and air volume flow. can be incorporated in any project and executed as a native
application on the DEOS system architecture.
These values are derived from a set of interdependent
setpoint ranges as defined by end users according to project Finally, the extensive use of icons and graphics has resulted
specific requirements for room temperature, relative humidi- in an intuitive user interface which is language independent,
ty and air quality. reducing training overheads to an absolute minimum.

At its core, OPENdynamics attempts to achieve and main- OPENdynamics is available with text-guided or graphic-
tain the most economical operating conditions; continuous- guided user interface.
ly adjusting setpoints based on real time measurements
and published energy prices. Most notably, the underlying The presentation of the information is transmitted via Inter-
decision making process has been kept transparent, visually net Explorer or via OPENview Control Panel.
highlighting the reasoning behind OPENdynamics’s choice
of parameters, whilst providing a breakdown of various The text-guided version is standard and as such it is always
running costs. activated for use. The graphical version is activated for 6
months, starting at the date of delivery by DEOS AG.
By calculating real time operating costs OPENdynamics Thereafter, further unlimited licensing must be purchased.
transcends conventional expectations of a building manage-
ment system, thus providing the additional functionality of
a holistic Cost Management System. Furthermore, since

Patentiert durch das


deutsche Patent- und
Markenamt
OPENdynamics at a glance.
Patent Nr.: DE 10 2009 016 418
Patentierter DEOS AG Regelalgorithmus
für Klima- und Lüftungsanlagen

With OPENdynamics you get:

• The security of an operating point that is always cost-effective


• Constant control of your air-conditioning energy costs
• Increased comfort in each room through reduced air flow rates
• Energy cost savings through reducing the air flow rate

62 C 2018 - Technical changes excepted. Pictures similar.


Efficiency Solutions OPENdynamics

Article Type Art.-No.


OPENdynamics

Efficiency solutions
Notes:
To operate OPENdynamics, we recommend
using OPENweb BMS software.
If OPENweb is not used, the corresponding activation for
OPENview is required on the OPEN EMS. The OPENview
option must be purchased separately.

Please note that each OPEN EMS type has a different number
of IOs, which may, in turn, limit the use of a higher number of
zones.

Supported OPEN EMS units


OPENdynamics can be activated on all OPEN EMS units.
As the number of IOs is limited (IOs not expandable) OPEN-
dynamics should not be activated on the OPEN 600 EMS
basic24.

OPENdynamics 16 zones DS-Odyn16 DS-371261


Activation of the OPENdynamics licence with 16 zones
on one of the main controllers listed under "Supported OPEN
EMS units".
OPENdynamics 32 zones DS-Odyn32 DS-371262
Activation of the OPENdynamics licence with 32 zones
on one of the main controllers listed under „Supported OPEN
EMS units“
OPENdynamics 48 zones DS-Odyn48 DS-371263
Activation of the OPENdynamics licence with 48 zones
on one of the main controllers listed under „Supported OPEN
EMS units“

C 2018 - Technical changes excepted. Pictured products similar. 63


OPENapp Efficiency Solutions

OPENapp

The software application OPENapp combines intuitive use


with the reliability of a standard controller. Thanks to its gra-
phic configuration, programming skills are no longer necessa-
ry.

This makes OPENapp the ideal and individual solution for


small and medium-sized projects. During commissioning,
operation and maintenance, you benefit from the following
advantages:

• High flexibility
• Fully graphic configuration and central operation on the
OPEN 600 EMS
• Powerful web server allows remote monitoring
• Reduced commissioning time
• Parameters are saved upon project completion
• Various security access levels
• Logic functions for special requirements

The standard controller OPENapp is available in two versions:

OPENapp OPENapp
HVAC HVAC Package Units
Heating circuits 
Boiler and

twin boiler systems
Water heating 
District heating 
Ventilation system 
Free time switches 
HVAC Package Units 
Return (Exhaust) air  
fans
Logic functions  

Note for OPENapp:

• The OPENapp software application can only be loaded on


OPEN 600 EMS controllers.

• For the use of OPENapp the activation of OPENview on


OPEN 600 EMS is necessary.

• The purchase of the OPENapp software application contains


the activation of OPENview on the accordant OPEN 600
EMS without extra charge.

• If OPENview is already activated on a OPEN 600 EMS, as


system partner you can activate OPENapp on the OPEN 600
EMS without charge.

64 C 2018 - Technical changes excepted. Pictures similar.


Efficiency Solutions OPENapp

Article Type Art.-No.


OPENapp 600/0 DS-OPENapp HVAC 600/0 DS-371218
OPENapp software applications, version HVAC,

Efficiency solutions
for the following OPEN controllers:

• OPEN 600/0 EMS


• OPEN 600H/0 EMS

OPENapp 600/5 DS-OPENapp HVAC 600/5 DS-371219


OPENapp software applications, version HVAC,
for the following OPEN controllers:

• OPEN 600/5 EMS


• OPEN 600H/5 EMS

OPENapp 600/0 DS-OPENapp PU 600/0 DS-371251


OPENapp software applications,
version Package Units,
for the following OPEN controllers:

• OPEN 600/0 EMS


• OPEN 600H/0 EMS

OPENapp 600/5 DS-OPENapp PU 600/5 DS-371252


OPENapp software applications,
version Package Units,
for the following OPEN controllers:

• OPEN 600/5 EMS


• OPEN 600H/5 EMS

C 2018 - Technical changes excepted. Pictured products similar. 65


Notice

Light at its very best!

Join us in ushering in a new era of controller technology:


openapp@deos-ag.com

66 C 2018 - Technical changes excepted. Pictures similar.


Control Units
Control Units
Control Units Page
Touch control 68
LED touch screen 70
Embedded Touch-PC 10.1" 71
Touch User Panel 5.7" 72
Touch User Panel 3.5" 73
GALAXY One - BACnet MS/TP ®
74
GALAXY One - CAN-bus 76
CORA - BACnet MS/TP
®
78
CORA - CAN-bus 79
CODI - CAN-bus 80
LVB - Manual Emergency Control 81

C 2018 - Technical changes excepted. Pictured products similar. 67


Touch Control Control unit OPEN
Preis / Leistung

Einsteigerbereich Basisbereich Komfortbereich

TUP Embedded Touch-PC Touch LED Monitor +


3.5" und 5.7" Display 10.1" Display Mini PC
15.6", 19,5" und 21,5“
Display

Anwendungsbereiche

Touch control for the switch cabinet installation


This built-in solution for the switch cabinet allows you to con- We will be happy to help you in configuring your individual
veniently control the DEOS building automation solution, also hardware. Tell us your requirements and we will plan your
in full HD depending on the model. solution.

A customized solution can be created using two combinable From a simple control PC and a 24/7-capable BMS master
items: computer to the highly available server solution, we offer you a
wide range of products.
• the LED touch screen with a 16:9 format – available in diffe-
rent sizes for front mounting as well as Please also see our networking and cloud solution DEOS
• the mini PC for mounting at the rear of the touch screen. Cloud Solutions on page 100.

There are two mounting options available with visible screws


(included) or with a visually appealing mounting cover with On request, you can receive your customized offer by telepho-
concealed screws. ne or via e-mail:

Components are used for 24-hour operation, seven days a * it@deos-ag.com


week (24/7). ( +49 5971 91133-3333
This touch screen/mini PC solution can be easily and quickly
installed in switch cabinets or other fronts.

We supply the system ready to operate and connect with all


the necessary installation kits, cabling and power supplies as
well as the preinstalled DEOS software and touch drives.

68 C 2018 - Technical changes excepted. Pictures similar.


Control unit OPEN LED touch screen

Article Type Art.-No.

Control Units
LED touch screen 15.6“ DS-Touch15.6 DS-360161
Display size: 15.6“, resolution: 1366 x 768
Dimensions: 376.8 x 221.1 x 46.3 mm
Dimensions with brackets: 400.8 x 245.1 mm

Optional mounting cover 15.6“ DS-Cover15.6 DS-360164


Installation with concealed screws
Dimensions with mounting cover: 415.8 x 260.1 mm

LED touch screen 19.5“ DS-Touch19.5 DS-360162


Display size: 19.5“, resolution: 1920 x 1080
Dimensions: 476 x 280,1 x 43.4 mm
Dimensions with brackets: 500 x 304.1 mm

Optional mounting cover 19.5“ DS-Cover19.5 DS-360165


Installation with concealed screws
Dimensions with mounting cover: 516.3 x 320.4 mm

LED touch screen 21.5“ DS-Touch21.5 DS-360163


Display size: 21.5“, resolution: 1920 x 1080
Dimensions: 511.8 x 298.2 x 42 mm
Dimensions with brackets: 535.7 x 322.2 mm

Optional mounting cover 21.5“ DS-Cover21.5 DS-360166


Installation with concealed screws
Dimensions with mounting cover: 551.6 x 338.1 mm

Mini PC – Basic DS-MiniPC-B DS-360167


Application: basic operation
SSD: 120 GB, RAM: 4GB
CPU: Intel Pentium or comparable

Mini PC – Advanced DS-MiniPC-Ad DS-360168


Application: OPENweb in micro installations
SSD: 150 GB, RAM: 4GB
CPU: Intel Core i3 or comparable

C 2018 - Technical changes excepted. Pictured products similar. 69


Embedded Touch-PC 10.1" Control unit OPEN

Description
The graphical operating devices for the OPEN
control systems have been set up by DEOS AG
especially to meet the requirements of our users.
Technical information (Changes excepted)
We offer you a variety of powerful graphical
• Display: 25,65 cm (10.1")
operating devices for installation in the switch
• Aspect: 16:10
cabinet door – here, the embedded 10.1" touch
• Resolution: 1280 x 800 Pixel
PC as an industry-oriented android operating de-
• Power supply: 12 V DC
vice for 24/7 operation. All the necessary DEOS
external power supply unit
applications are installed and pre-configured in
• Power usage: 18 W
the android environment of the touch PC – which
• Connections: 2x USB 2.0
makes it immediately ready for use. The DEOS
1x USB OTG
OPENweb app puts the operation of the DEOS
1x serial
GLT (OPENweb) under your control. The DEOS
1x Audio-In / 1x Audio-Out
OPENview app lets you monitor and operate the
1x WLAN
configured OPEN EMS systems.
1x HDMI
• Network: 10M/100M/1000M RJ45; WLAN
Items supplied
• Operating System: Android 4.4
• Embedded 10.1“ Touch PC
• Battery: -/-
• Plug-in power supply
• Ambient temperature: -20 … 75 °C
• Assembly set incl. 2x mounting brackets
• Ambient humidity: 10 ... 90%
• Assembly screws, locknuts, rubber feet
• IP protection class: IP65 (front case)
• OPENweb app and OPENview app (pre-ins-
• Dimensions (WxHxD): 276 mm x 34 mm x 192 mm
talled and free of charge) • Case Color: black
• Weight: 2,0 kg net / 2,9 kg gross

Article Type Art.-No.


Embedded Touch-PC 10.1" DS-Touch PC 10.1", DS-360157
Android

Important note:
In the event of a warranty claim, we cannot guarantee that the same device will be delivered as a replacement. In
this case, we reserve the right to supply a device of equal quality. If changes are made to the standby settings, the
guarantee will become void. For operation via the graphical interface, the activated graphical OPENview option is
required on the respective OPEN EMS.

70 C 2018 - Technical changes excepted. Pictures similar.


Embedded Touch-PC 10.1"

Control unit OPEN


Datenblatt – Stand: 14.06.2017 - V1.0 Embedded Touch-PC 10.1"
Ansicht

Status-LED
Multi-Touch-Display
W-LAN-Antennenanschluss
COM-Schnittstelle
Lautsprecher
USB OTG
GPIO
Audio-Out
Audio-In
HDMI-Schnittstelle
LAN
SIM-Karte
2x USB 2.0
8 … 36 V DC-IN
(verschraubbar)

Control Units
Lochausschnitt

Dimensions (in mm)

Mounting instructions
To assembly the device, create a hole cut-out – dimensi-
© DEOS AG 2017. Technische Änderungen und Irrtümer vorbehalten.

ons 240 mm x 165 mm (WxH) – in the switch cabinet door.


Mount the device flush in the hole cut-out of the switch
cabinet door from the outside. The assembly set is included
in the delivery free of charge.

Maße in mm

DEOS AG
Birkenallee 76 ▪ 48432 Rheine ▪ Germany ▪ +49 5971 91133-0 ▪ +49 5971 91133-2999 ▪ info@deos-ag.com ▪ www.deos-ag.com 4

C 2018 - Technical changes excepted. Pictured products similar. 71


TUP 5.7 Control unit OPEN

cutout for switch panel mounting:


157,0 mm x 117,0 mm, +/- 1

Description Dimensions
The Touch User Panel is a control unit with a
5.7“ (14,6 cm) color TFT display, incl. Windows
CE. The TUP is connected via TCP / IP and ser-
ves to control all OPEN EMS without
OPENweb and/or OPENview. Individual program-
ming and configuring of user level is executed
using the programming software FUP XL. The
TUP is designed for installation in control cabinet
doors or in other control panels.

Power supply 24 V DC
Current consumption approx. 0.4 A
Size (WxHxD) 170 x 130 x 39 mm
Display 5.7“ color TFT
Resolution 640 x 480 pixel
Touch Screen Resistiv-Touch
Processor RISC, 32 Bit, 400 MHz
DRAM 64MB
SD Memory Card Slot 1, loaded with 1 GB
Ethernet onboard 10/100 Mbps

Article Type Art.-No.


Touch User Panel DS-TUP.103 DS-360106
with 5.7“ color TFT-Display,
to control all OPEN EMS controllers

72 C 2018 - Technical changes excepted. Pictures similar.


Control unit OPEN TUP 3.5

cutout for switch panel mounting:


123 mm x 87 mm, +/- 1

Control Units
Description Dimensions
The Touch User Panel is a control unit with a
3.5“ (8,96 cm) color TFT-Display, incl. Windows
CE. The TUP is connected via TCP / IP and ser-
ves to control all OPEN EMS without OPENweb
and/or OPENview. Individual programming and
configuring of user level of the Touch User Panels
is executed using the programming software FUP
XL. The TUP is designed for installation in control
cabinet doors or in other control panels.

Power supply 24 V DC
Current consumption approx. 0,2 A
Size (WxHxD) 136 x 100 x 30 mm
Display 3.5“ color TFT
Resolution 320 x 240 pixel
Touch Screen Resistiv-Touch
Processor RISC, 32Bit, 400 MHz
DRAM 64 MB
SD Memory Card Slot 1, loaded with 1 GB
Ethernet onboard 10/100 Mbps

Article Type Art.-No.


Touch User Panel DS-TUP.102 DS-360071
with 3.5“ color TFT-Display,
to control all OPEN EMS controllers.

C 2018 - Technical changes excepted. Pictured products similar. 73


GALAXY One – BACnet® MS/TP Control unit OPEN

Description Technical Data


The GALAXY One is designed as a single- Housing and frame are mounted ex work.
room control unit for HVAC installations, lighting
and blinds. It can easily be integrated into the Power supply 24 V DC ± 10 %
OPEN control system. The GALAXY One is Dimensions see dimensions
installed in a standard flush-mounted socket. The Current consumption max. 70 mA
communication is done via BACnet MS/TP. BACnet MS/TP Baudrate configurable
via display menue (9600, 19200,
There is a backlit LCD display with symbols for 38400, 57600, 76800, 115200 Baud)
the controlled systems. Depending on the type of Terminals Screw terminals max. 1.5 mm²
unit, up to 4, 8 or 12 operating buttons are availa- Internal terminating resistor 120 Ohm, switchable
ble for setting values, lighting control or shading Temperature sensor 0 .. 50 °C
control. The unit features illuminated operating Housing Material ABS
buttons for colored status indications, and an LCD display 39 x 51 mm
integrated temperature sensor. Button labelling with inlays for individual labels
Housing protection IP30 acc. EN 60529
Ambient temperature 0 .. 50°C
Ambient air humidity < 85 % rh, non-condensating

Dimensions
with frame w/o frame

74 C 2018 - Technical changes excepted. Pictures similar.


Control unit OPEN GALAXY One – BACnet® MS/TP

Control Units
Housing color: anthracite Housing color: aluminium Housing color: pure white Housing color: anthracite
with design frame with design frame with design frame with design frame
“Brushed stainless steel” “Midnight” “Glass fluted” “Dusk”

Article Type Art.-No.


GALAXY One
Individual control unit for single room control of HVAC,
lighting, and blinds.
Housing color: pure white, version with
4 operating buttons DS-GO 4T rw BAC DS-360084
8 operating buttons DS-GO 8T rw BAC DS-360085
12 operating buttons DS-GO 12T rw BAC DS-360086
Housing color: anthracite, version with
4 operating buttons DS-GO 4T az BAC DS-360087
8 operating buttons DS-GO 8T az BAC DS-360088
12 operating buttons DS-GO 12T az BAC DS-360089
Housing color: aluminium, version with
4 operating buttons DS-GO 4T al BAC DS-360090
8 operating buttons DS-GO 8T al BAC DS-360091
12 operating buttons DS-GO 12T al BAC DS-360092
Frame
Design frame „Dusk“ DS-GO-RD DS-360042
Design frame „Midnight“ DS-GO-RM DS-360043
Design frame „Glass, flutedt“ DS-GO-RG DS-360044
Design frame „Brushed stainless steel“ DS-GO-EG DS-360054

Note:
The GALAXY One and the design-frame will be manufactured and customized order-related.
A return of these pre-assembled items is excluded.

C 2018 - Technical changes excepted. Pictured products similar. 75


GALAXY One – CAN-bus Control unit OPEN

Description Technical Data


The GALAXY One is designed as a single- Housing and frame are mounted ex work.
room control unit for HVAC installations, lighting
and blinds. It can easily be integrated into the Power supply 24 V DC ± 10 %
OPEN control system. The GALAXY One is Dimensions see dimensions
installed in a standard flush-mounted socket. The Current consumption max. 70 mA
communication is done via CAN-bus. CAN-bus adjustable from 10 kBit/s to 125 kBit/s
Standard: 50 kBit/s
There is a backlit LCD display with symbols for Terminals Screw terminals, max. 1.5 mm²
the controlled systems. Depending on the type of Internal terminating resistor 120 Ohm, switchable
unit, up to 4, 8 or 12 operating buttons are availa- Temperature sensor 0 .. 50 °C
ble for setting values, lighting control or shading Housing Material ABS
control. The unit features illuminated operating LCD display 39 x 51 mm
buttons for colored status indications, and an Button labelling with inlays for individual labels
integrated temperature sensor. Housing protection IP30 acc. EN 60529
Ambient temperature 0 .. 50°C
Ambient air humidity < 85 % rh, non-condensating

Dimensions
with frame w/o frame

76 C 2018 - Technical changes excepted. Pictures similar.


Control unit OPEN GALAXY One – CAN-bus

Control Units
Housing color: anthracite Housing color: aluminium Housing color: pure white Housing color: anthracite
with design frame with design frame with design frame with design frame
“Brushed stainless steel” “Midnight” “Glass fluted” “Dusk”

Article Type Art.-No.


GALAXY One
Individual control unit for single room control of HVAC,
lighting, and blinds.
Housing color: pure white, version with
4 operating buttons DS-GO 4T rw DS-360033
8 operating buttons DS-GO 8T rw DS-360034
12 operating buttons DS-GO 12T rw DS-360035
Housing color: anthracite, version with
4 operating buttons DS-GO 4T az DS-360036
8 operating buttons DS-GO 8T az DS-360037
12 operating buttons DS-GO 12T az DS-360038
Housing color: aluminium, version with
4 operating buttons DS-GO 4T al DS-360039
8 operating buttons DS-GO 8T al DS-360040
12 operating buttons DS-GO 12T al DS-360041
Frame
Design frame „Dusk“ DS-GO-RD DS-360042
Design frame „Midnight“ DS-GO-RM DS-360043
Design frame „Glass, fluted“ DS-GO-RG DS-360044
Design frame „Brushed stainless steel DS-GO-EG DS-360054

Note:
The GALAXY One and the design-frame will be manufactured and customized order-related.
A return of these pre-assembled items is excluded.

C 2018 - Technical changes excepted. Pictured products similar. 77


CORA – BACnet® MS/TP Control unit OPEN

Description Dimensions
The CORA - BACnet® is a BACnet Application
Specific Controller (B-ASC). It is a compact,
BACnet MS/TP room control unit with extensive
functions. It has been designed specifically for the
simple control e.g. of fans with up to 5 operating
modes (Off, Stage 1-3, Automatic).

Other features, like set point potentiometer,


control buttons with LED, e.g. for heating time
extension, and an integrated room temperature
sensor makes CORA an universal control unit for
room automation. All functions can be addressed
via BACnet objects. For detailed information on
supported BACnet objects and BACnet services
refer to the data sheet „BACnet Protocol Imple-
mentation Conformance Statement“ (PICS).
Optional the CORA is available with an integrated
motion detector.
CORA comes with a selection of prefabricated
descriptions for diverse applications. Dimensions (WxHxD) 84 mm x 84 mm x 28 mm
Color similar RAL 9010
Voltage supply 24 V DC ±10%, approx. 30 mA
24 V AC ±10%, approx. 60 mA

Article Type Art.-No.


Room control unit with BACnet® MS/TP for variable DS-CORA-B DS-360062
stage setting with up to 5 operating modes.
Housing designed for wall mounting.

Room control unit with BACnet® MS/TP for variable DS-CORA-B/MD DS-360063
stage setting with up to 5 operating modes.
Additionally with integrated motion detector.
Housing designed for wall mounting.

Note: Find the corresponding labelling kit on page 80.


Find For high quantities, special prices will be offered.
78 C 2018 - Technical changes excepted. Pictures similar.
Control unit OPEN CORA – CAN-bus

Control Units
Description Dimensions
The CORA is a compact, bus-compatible room
control unit with extensive functions. It has been
designed specifically for the simple control e.g.
of fans with up to 5 operating modes (Off, Stage
1-3, Automatic). CORA is fully integrated into the
FUP XL environment, and with it´s CAN-bus it is
easily linked with the OPEN system.

Other features, like set point potentiometer,


control buttons with LED, e.g. for heating time
extension, and an integrated room temperature
sensor makes CORA an universal control unit for
room automation. All functions can be addressed
via CAN-bus.
Optional the CORA is available with an integrated
motion detector.

CORA comes with a selection of prefabricated


descriptions for diverse applications.
Dimensions (WxHxD) 84 mm x 84 mm x 28 mm
Color similar RAL 9010
Voltage supply 24 V DC ±10%, approx. 30 mA
24 V AC ±10%, approx. 60 mA

Article Type Art.-No.


Room control unit with CAN-bus for variable DS-CORA-C DS-360048
stage setting with up to 5 operating modes.
Housing designed for wall mounting.

Room control unit with CAN-bus for variable DS-CORA-C/MD DS-360049


stage setting with up to 5 operating modes.
Additionally with integrated motion detector.
Housing designed for wall mounting.

Note: Find the corresponding labelling kit on page 80.


Find For high quantities, special prices will be offered.
C 2018 - Technical changes excepted. Pictured products similar. 79
CODI – CAN-bus Control unit OPEN

Description Dimensions
The CODI is a compact, bus-compatible room
control unit with a LCD and extensive functions. It
has been designed specifically for the simple con-
trol e.g. of fans with up to 5 operating modes (Off,
Stage 1-3, Automatic). CODI is fully integrated
into the FUP XL environment, and with it´s CAN-
bus it is easily linked with the OPEN system.

Other features, like LCD for display of


temperature and humidity, set point buttons,
control buttons with LED, e.g. for heating time
extension, and an integrated room temperature
sensor makes CODI an universal control unit for
room automation. All functions can be addressed
via CAN-bus.

CODI comes with a selection of prefabricated


descriptions for various applications.

Dimensions (WxHxD) 84 mm x 84 mm x 28 mm
Color similar RAL 9010
Voltage supply 24 V AC/DC ±10%, approx. 30 mA

Article Type Art.-No.


Room control unit with CAN-bus for variable DS-CODI-C DS-360129
stage setting with up to 5 operating modes and
LCD for display of temperature and humidity.
Housing designed for wall mounting.

Accessories CORA and CODI Typ Art.-Nr.


Labelling kit including DS-BSET-CORA DS-080032
12 different labelling panels and
12 appropriate protective covers for the labelling panels NEU
NEW
Notes: For high quantities, special prices will be offered.

80 C 2018 - Technical changes excepted. Pictures similar.


Control Units
LVB / Manual Control Level
Control Modules Page
General fault indicator modules 84
Indicator modules 85
Switching modules with relay output 230 V 86
Switching modules w/o relay output 24 V 88
Switching modules Close/Open with relay output 230 V 90
Switching modules Close/Open w/o relay output 24 V 91
Switching modules Hold/Close/Open with relay output 230 V 92
Switching modules Hold/Close/Open w/o relay output 24 V 93
Analog modules 0 .. 10 V 94
Combi-modules 95
Button modules 96
Special modules 97

Accessories 98

LVB acc. To VDI 3814 Page1 = local priority control / indicator module (before: Emergency control)

C 2018 - Technical changes excepted. Pictured products similar. 81


Overview LVB / Manual Control Level

Type Function Article Page


General report
DS-HGL SA message, potential contact, lamptest DS-530001 84
DS-HGLN SA message, potential contact, lamptest, new value, warning horn DS-530002 84
Reporting modules
DS-HM599A 5 Lines, Red/Green/Yellow, working current DS-530003 85
DS-HM599B 5 Lines, Red/Green/Yellow, zero current or working current DS-530033 85
DS-HM699A 10 Lines, Red/Green/Yellow, working current DS-530004 85
DS-HM699B 10 Lines, Red/Green/Yellow, zero current or working current DS-530034 85
Switching modules with relay output 230 V
DS-HS211R 2 x 1 stage, A-0-1-0, Oper./Fault with coupler relay, contacts 230 V DS-530005 86
DS-HS411R 4 x 1 stage, A-0-1-0, Oper./Fault with coupler relay, contacts 230 V DS-530006 86
DS-HS219R 2 x 1 stage, 1-0-1-0, Oper./Fault with coupler relay, contacts 230 V DS-530040 86
DS-HS122R 1 x 2 stage, A-0-1-2, Oper./Fault with coupler relay, contacts 230 V DS-530007 87
DS-HS222R 2 x 2 stage, A-0-1-2, Oper./Fault with coupler relay, contacts 230 V DS-530008 87
DS-HS133R 1 x 3 stage, A-O-H-0,1-2-3-(0), Oper./Fault with coupler relay, contacts 230V DS-530009 87

Switching modules w/o coupler relay 24 V

DS-HS211X 2 x 1 stage, A-0-1-0, Oper./Fault, w/o coupler relay, 24 V DS-530010 88

DS-HS411X 4 x 1 stage, A-0-1-0, Oper./Fault, w/o coupler relay, 24 V DS-530011 88

DS-HS122X 1 x 2 stage, A-0-1-2, Oper./Fault, w/o coupler relay, 24 V DS-530012 89

DS-HS222X 2 x 2 stage, A-0-1-2, Oper./Fault, w/o coupler relay, 24 V DS-530013 89

Switching modules Close/Open with relay output 230 V

DS-HS254R 2 x 2 point, Auto-Z-A-Z, 4 LED, with coupler relay, contacts 230 V DS-530014 90

DS-HS454R 4 x 2 point, Auto-Z-A-Z, 8 LED, with coupler relay, contacts 230 V DS-530015 90

Switching modules Close/Open, w/o coupler relay 24 V

DS-HS254X 2 x 2 point, Auto-Z-A-Z, 4 LED, w/o coupler relay, 24 V DS-530016 91

DS-HS454X 4 x 2 point, Auto-Z-A-Z, 8 LED, w/o coupler relay, 24 V DS-530017 91

Switching modules Hold/Close/Open, with relay output 230 V

DS-HS165R 1 x 3 point, Auto-Hold-Close-Open, 2 LED, with coupler relay, contacts 230 V DS-530018 92

DS-HS265R 2 x 3 point, Auto-Hold-Close-Open, 4 LED, with coupler relay, contacts 230 V DS-530019 92
Switching modules Hold/Close/Open, w/o coupler relay 24 V
DS-HS165X 1 x 3 point, Auto-Hold-Close-Open, 2 LED, w/o coupler relay, 24 V DS-530031 93
DS-HS265X 2 x 3 point, Auto-Hold-Close-Open, 4 LED, w/o coupler relay, 24 V DS-530032 93

82 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Overview

Type Function Article Page


Analog modules 0 .. 10 V
DS-HA206D 2 x 0 .. 10 V, Auto-Close-Open-Rheo, Rheostat, Dimming LED DS-530020 94
DS-HA406D 4 x 0 .. 10 V, Auto-Close-Open-Rheo, Rheostat, Dimming LED DS-530021 94
DS-HA407D 4 x 0 .. 10 V, Setpoint -/+, Rheostat, Dimming LED DS-530043 94
Combi-modules
DS-HK201R 1 x 0 .. 10 V analog; 1 x 1 stage, with coupler relay, contacts 230 V DS-530035 95
DS-HK261R 1 x 3 point, Auto-Hold-Close-Open; 1 x 1 stage, with coupler relay, contacts DS-530036 95
230V
Key contact modules
DS-HT297R 2 keys, 2 LED each, with coupler relay, contacts 230 V DS-530022 96
DS-HT497R 4 keys, 2 LED each, with coupler relay, contacts 230 V DS-530023 96

Control Units
Special module
DS-HS21FU1R Frequency converter with bypass mode DS-530038 97
Accessories
Mounting rack 98
Blind covers DS-530030 98
Connecting lines 98
DS-LVB-B Labeling sheet LVB DS-080036 98

C 2018 - Technical changes excepted. Pictured products similar. 83


General fault indicator modules LVB / Manual Control Level

Article Type Art.-No.


General fault indicator module DS-HGL DS-530001
• General fault indication LED red
• General fault output
1 make contact 1 break contact, 1A, 230V AC12
• Lamp test switch
• LED green supply voltage
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

General fault indicator module DS-HGLN DS-530002


• General fault indication LED red
• General fault output
1 make contact 1, break contact 1A / 230V AC 12
• Lamp test switch
• LED green supply voltage
• Two Duo LEDs Red/Green secondary color yellow)
for random use
• SAS LED, General fault, static
• SAN LED, General fault, report of new value
• Internal warning horn.
- Can be suppressed by pulling a jumper.
• Switch Horn acknowledge,
acts onto internal and external horns
• Connection for external horn 24V 100mA
• Connection for switch external horn acknowledge
• (Make contact), acts onto internal and external horns.
• Switch Fault acknowledge, 1 Change-over contact, 1A /
230V AC
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

2
AC1 = resistive load

84 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Indicator modules

Article Type Art.-No.


Indicator module for fault / operational / warning DS-HM599A DS-530003
messages, 5 reporting lines, working current principle

• Message selected via jumper


• Operational message green
• Error message red
• message not invertible
• Selected by jumper
• Static general message
• Report of new value
• Priory setting general fault SAS
• LED green supply voltage
• Lamp test
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Control Units
Reporting module for faults /operational / warning DS-HM599B DS-530033
messages, 5 reporting lines,
choice of zero current or load current principle

• Reports can be inverted,


otherwise as with HM599A

Indicator module for fault / operational / warning DS-HM699A DS-530004


messages, 10 reporting lines, working current principle

• Message selected via jumper


• Operational message green
• Error message red
• message not invertible
• Selected by jumper
• Static general message
• Report of new value
• Priory setting general fault SAS
• LED green supply voltage
• Lamp test
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Reporting module for faults /operational / warning DS-HM699B DS-530034


messages, 10 reporting lines,choice of zero current or
load current principle

• Reports can be inverted,


otherwise as with HM699A

C 2018 - Technical changes excepted. Pictured products similar. 85


Switching modules LVB / Manual Control Level

Article Type Art.-No.


Emergency control for single stage applications DS-HS211R DS-530005
2 channels with coupler relay

• Rotary switch (Auto-0-1-0)


• Switch acknowledgement in position Auto closed,
potential-free
• Coupler relay, 1 Change-over contact1
• LED green supply voltage
• Lamp test
• LED green - Operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.
Emergency control for single stage applications, DS-HS411R DS-530006
4 channels with coupler relay

• Rotary switch (Auto-0-1-0)


• Switch acknowledgement in position Auto closed,
potential-free
• Coupler relay, 1 Change-over contact1
• LED green supply voltage
• Lamp test
• LED green - Operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.
Emergency control for single stage applications, DS-HS219R DS-530040
2 channels with coupler relay

• Rotary switch (1-0-1-0)


• Switch acknoledgement with left switching position
closed potential-free
• Coupler relay 1 Change- over contact1
• LED green supply voltage
• Lamp test
• LED green - Operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Note:
The first switch setting „1“ is potential-free, the second switch setting “1”
connects the internally impressed voltage to the output.

Max.load of output contacts


1

230 V AC; 3,0 A / AC12


230 V AC; 0,8 A / AC152
24 V DC; 1,1 A / DC132
230 V DC; 0,12 A / Dc132

AC1=resistive load
2

AC15=monitoring of electro-magnetic load, aux. current switches,


power contactors, solenoid valves, and electro-magnets
DC13= monitoring of aux. current switches, power contactors,
solenoid valves, electro-magnets

86 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Switching modules

Article Type Art.-No.


Emergency control for two-stage applications, DS-HS122R DS-530007
1 channel with coupler relay

• Rotary switch (Auto-0-1-2)


• Switch acknowledgement in position Auto
closed potential-free
• Coupler relay, 1 Change-over contact1
• LED green supply voltage
• Lamp test
• 2 LED green - Operating status, Stage 1, Stage 2
• 2 LED red - Error messages
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.
Emergency control for two-stage applications, DS-HS222R DS-530008

Control Units
2 channel with coupler relay

• Rotary switch (Auto-0-1-2)


• Switch acknowledgement in position Auto
closed potential-free
• Coupler relay, 1 Change-over contact1
• LED green Supply voltage
• Lamp test
• 2 LED green - Operating status, Stage 1, Stage 2
• 2 LED red - Error messages
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.
Emergency control for three-stage applications, DS-HS133R DS-530009
1 channel with coupler relay

• Rotary switch (S1: Auto-0-Hand-0 ) (S2: 1-2-3)


• Switch acknowledgement in position Auto
closed potential-free
• Coupler relay, 1 Change-over contact1
• LED green supply voltage
• Lamp test
• 3 LED green - Operating status Stage 1, Stage 2, Stage 3
• 3 LED red - Error messages
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

1
Max.load of output contacts
230 V AC; 3,0 A / AC12
230 V AC; 0,8 A / AC152
24 V DC; 1,1 A / DC132
230 V DC; 0,12 A / Dc132

2
AC1=resistive load
AC15=monitoring of electro-magnetic load, aux. current switches,
power contactors, solenoid valves, and electro-magnets
DC13= monitoring of aux. current switches, power contactors,
solenoid valves, electro-magnets

C 2018 - Technical changes excepted. Pictured products similar. 87


Switching modules LVB / Manual Control Level

Article Type Art.-No.


Emergency control for single-stage applications, DS-HS211X DS-530010
2 channels

• Rotary switch (Auto-0-1-0), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• LED green - Operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Emergency control for single-stage applications, DS-HS411X DS-530011


4 channels

• Rotary switch (Auto-0-1-0), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• LED green - Operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

88 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Switching modules

Article Type Art.-No.


Emergency control for two-stage applications, DS-HS122X DS-530012
1 channel

• Rotary switch (Auto-0-1-2), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• 2 LED green - Operating status Stage1, Stage2
• 2 LED red - Error messages
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Control Units
Emergency control for two-stage applications, DS-HS222X DS-530013
2 channels

• Rotary switch (Auto-0-1-2), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• 2 LED green - Operating status Stage1, Stage2
• 2 LED red- Error messages
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

C 2018 - Technical changes excepted. Pictured products similar. 89


Switching modules LVB / Manual Control Level

Article Type Art.-No.


Emergency control for Open-Close applications, 2 chan- DS-HS254R DS-530014
nels, with coupler relay

• Rotary switch (Auto-Close-Open-Close)


• Switch acknowledgement in position Auto
closed potential-free
• Coupler relay, 1 change-over contact each1
• LED green Supply voltage
• Lamp test
• 2 LED green - Open-Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Emergency control for Open-Close applications, 4 chan- DS-HS454R DS-530015


nels, with coupler relay

• Rotary switch (Auto-Close-Open-Close)


• Switch acknowledgement in position Auto
closed potential-free
• Coupler relay, 1 change-over contact each1
• LED green Supply voltage
• Lamp test
• 2 LED green - Open-Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Max.load of output contacts


1

230 V AC; 3,0 A / AC12


230 V AC; 0,8 A / AC152
24 V DC; 1,1 A / DC132
230 V DC; 0,12 A / Dc132

AC1=resistive load
2

AC15=monitoring of electro-magnetic load, aux. current switches,


power contactors, solenoid valves, and electro-magnets
DC13= monitoring of aux. current switches, power contactors,
solenoid valves, electro-magnets

90 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Switching modules

Article Type Art.-No.


Emergency control for Open/Close applications, DS-HS254X DS-530016
2 channels

• Rotary switch (Auto-Close-Open-Close), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• 2 LED green - Open-Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Control Units
Emergency control for Open/Close applications, DS-HS454X DS-530017
4 channels

• Rotary switch (Auto-Close-Open-Close), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• 2 LED green - Open-Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

C 2018 - Technical changes excepted. Pictured products similar. 91


Switching modules LVB / Manual Control Level

Article Type Art.-No.


Emergency control for Auto/Hold/Close/Open DS-HS165R DS-530018
applications , 1 channel with coupler relay

• Rotary switch ( Auto-Hold-Close-Open )


• Switch acknowledgement in position Auto
closed potential-free
• Coupler relay, 1 change-over contact each1,
• LED green Supply voltage
• Lamp test
• 2 LED green- Open - Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Emergency control for Auto/Hold/Close/Open DS-HS265R DS-530019


applications , 2 channels with coupler relay

• Rotary switch (Auto-Hold-Close-Open)


• Switch acknowledgement in position Auto
closed potential-free
• Coupler relay, 1 change-over contact each1,
• LED green Supply voltage
• Lamp test
• 2 LED green - Open - Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Max.load of output contacts


1

230 V AC; 3,0 A / AC12


230 V AC; 0,8 A / AC152
24 V DC; 1,1 A / DC132
230 V DC; 0,12 A / Dc132

AC1=resistive load
2

AC15=monitoring of electro-magnetic load, aux. current switches,


power contactors, solenoid valves, and electro-magnets
DC13= monitoring of aux. current switches, power contactors,
solenoid valves, electro-magnets

92 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Switching modules

Article Type Art.-No.


Emergency control for Auto/Hold/Close/Open DS-HS165X DS-530031
applications , 1 channel

• Rotary switch (Auto-Hold-Close-Open), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• 2 LED green - Open-Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Control Units
Emergency control for Auto/Hold/Close/Open DS-HS265X DS-530032
applications , 2 channels

• Rotary switch (Auto-Hold-Close-Open), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• LED green Supply voltage
• Lamp test
• 2 LED green - Open-Close indication
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

C 2018 - Technical changes excepted. Pictured products similar. 93


Analog modules LVB / Manual Control Level

Article Type Art.-No.


Emergency control for analog applications, DS-HA206D DS-530020
2 channels

• Rotary switch (Auto-0 %-100 %-Rheo), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• Input voltage 0-10V DC
• Output voltage 0-10V DC, max. 1mA
• LED red (Dim),
bright / dimmed in relation to voltage level
• LED green supply voltage
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Emergency control for analog applications, DS-HA406D DS-530021


4 channels

• Rotary switch (Auto-0 %-100 %-Rheo), 24 V, 100 mA


• Switch acknowledgement in position Auto
closed potential-free
• Input voltage 0-10V DC
• Output voltage 0-10V DC, max. 1mA
• LED red (Dim),
bright / dimmed in relation to voltage level
• LED green, supply voltage
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Emergency control for analog applications, DS-HA407D DS-530043


4 channels, potentiometer for set point adjustment -/+

• Input voltage 0-10V DC


• Output voltage 0-10V DC, max. 1mA
• LED red (Dim),
bright / dimmed in relation to voltage level
• LED green, supply voltage
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

94 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Combi-modules

Article Type Art.-No.


Emergency operation for combined applications, DS-HK201R DS-530035
1 x analog and 1 x single/stage with coupler relay

• Rotary switch (Auto-0 %-100 %-Rheo), 24 V, 100 mA


• Switch acknowledgement in position Auto Closed,
potential-free
• 0-10V DC input and output voltage
• Output voltage 0-10V DC, max. 1mA
• LED red (Dim),
bright / dimmed in relation to voltage level

• Rotary switch (Auto-0-1-0)


• Switch acknowledgement in position Auto Closed,
potential-free
• Coupler relay 1 change-over contact1
• LED green, supply voltage
• Supply and signal voltage +24V AC/DC

Control Units
• Inscription with standard PC, printer and programmed temp-
lates on prepared DIN A4 sheets, which are included in the
price.

Emergency operation for combined applications DS-HK261R DS-530036


1 x Auto-Open-Hold-Close and
1 x single-stage with coupler relay

Rotary switch (Auto-Hold-Close-Open)


Switch acknowledgement in position Auto Closed,
potential-free
Coupler relay 1 change-over contact1

• Rotary switch (Auto-0-1-0)


• Switch acknowledgement in position Auto Closed,
potential-free
• Coupler relay, 1 change-over contact1
• LED green supply voltage
• Lamptest
• 2 LED green - Open-Close indication
• Supply and signal voltage +24V AC/DC

• Inscription with standard PC, printer and programmed temp-


lates on prepared DIN A4 sheets, which are included in the
price.

1
Max.load of output contacts
230 V AC; 3,0 A / AC12
230 V AC; 0,8 A / AC152
24 V DC; 1,1 A / DC132
230 V DC; 0,12 A / Dc132

2
AC1=resistive load
AC15=monitoring of electro-magnetic load, aux. current switches,
power contactors, solenoid valves, and electro-magnets
DC13= monitoring of aux. current switches, power contactors,
solenoid valves, electro-magnets

C 2018 - Technical changes excepted. Pictured products similar. 95


Button modules LVB / Manual Control Level

Article Type Art.-No.


Button module, 2 channels DS-HT297R DS-530022

• 2 control buttons
• 2 coupler relays, 1 Change/over contact each1,
• LED green Supply voltage
• Lamp test
• LED green - Operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Button module, 4 channels DS-HT497R DS-530023

• 4 control buttons
• 4 coupler relays, 1 Change-over relay each1
• LED green Supply voltage
• Lamp test
• LED green - Operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscriptions effected using PC, printer and programme forms
on prepared punched DIN A4 sheets which are included in
the price.

Max.load of output contacts


1

230 V AC; 3,0 A / AC12


230 V AC; 0,8 A / AC152
24 V DC; 1,1 A / DC132
230 V DC; 0,12 A / Dc132

AC1=resistive load
2

AC15=monitoring of electro-magnetic load, aux. current switches,


power contactors, solenoid valves, and electro-magnets
DC13= monitoring of aux. current switches, power contactors,
solenoid valves, electro-magnets

96 C 2018 - Technical changes excepted. Pictures similar.


LVB / Manual Control Level Special modules

Article Type Art.-No.


Emergency control for frequency converter, DS-HS21FU1R DS-530038
Application in bypass mode,
2 channels with coupler relay

• Rotary switch (FU-Bypass-Bypass-Bypass)


• Switch acknowledgement in position FU closed,
• potential-free
• Coupler relay, 1 ea. change-over contact 2
• LED green, supply voltage
• Lamp test
• LED green - operating status
• LED red - Error message
• Supply and signal voltage +24V AC/DC
• Inscription with standard PC, printer and programmed temp-
lates on prepared DIN A4 sheets, which are included in the
price.

Control Units

Max.load of output contacts


1

230 V AC; 3,0 A / AC12


230 V AC; 0,8 A / AC152
24 V DC; 1,1 A / DC132
230 V DC; 0,12 A / Dc132

AC1=resistive load
2

AC15=monitoring of electro-magnetic load, aux. current switches,


power contactors, solenoid valves, and electro-magnets
DC13= monitoring of aux. current switches, power contactors,
solenoid valves, electro-magnets

C 2018 - Technical changes excepted. Pictured products similar. 97


Accessories LVB / Manual Control Level

Mounting rack for modules of Emergency control level

Mounting rack 40TE 64TE 80TE 84TE

Cut-out figures
(+/- 0,2 mm)
Cut-out figures for control panel ( +/- 0,2 mm)

External dimensions

Article Type Art.-No.


Mounting rack for 5 (40TE) positions DS-HZR5 DS-530024
Mounting rack for 8 (64TE) positions DS-HZR8 DS-530025
Mounting rack for 10 (80TE) positions DS-HZR10 DS-530026
Mounting rack for 10 (84TE) positions DS-HZR10-19“ DS-530037
for installation in 19” cabinets
Blind cover for a module width DS-HZB1 DS-530030
Dimensions: B = 40,3 mm
H = 129 mm

Connecting cable with 5 module connectors DS-HZV5 DS-530027


Connecting cable with 8 module connectors DS-HZV8 DS-530028
Connecting cable with 10 module connectors DS-HZV10 DS-530029
Labeling sheet LVB DS-LVB-B DS-080036
Blank labelling sheet grey, perforated

98 C 2018 - Technical changes excepted. Pictures similar.


Accessories
Accessories Control Technology + IT
Accessories Control Technology and IT Page
Cloud Solutions 100
Modem 104
Voltage supply 106
CAN-bus cable 108
Bus cable, RS485 111
TCP / IP Controller 112
Interface converter 114
Batteries 115
Network accessories 116

C 2018 - Technical changes excepted. Pictured products similar. 99


Accessories Cloud Solutions

IT security in building automation

The IT security features included in DEOS Cloud Solutions technically use an open system structure based on standard IP tech-
nology. The objective of this solution portfolio is to provide maximum protection in preventing unauthorized access to the building
automation network, secure network properties, use the application programs, such as OPENweb or OPENenergy throughout the
entire project in a cost-effective manner and provide the user with maximum service and operability.

The DEOS solution networks properties together or to a central location, offers resource-saving secure remote access via the
Internet and includes a comprehensive range of modular services (e.g. regular virus scanner upgrades and readouts of log files
and reports on possible cyber attacks, etc.).
The solution and service portfolio of DEOS Cloud Solutions
rounds off the IT networking solution with additional products
and services. This makes it possible to efficiently set up user
software, such as building management system (OPENweb) or
the energy management with OPENenergy, in a cloud solution at OPEN IT OPEN IaaS
the customer‘s location or centrally at DEOS AG. ... cloud OPEN PaaS
OPEN SaaS
services
To this end, there are several solutions available such as plat-
form as a service in which DEOS AG offers the IT and hardware
platform, including computers, operating system and storage,
etc. in its own data center, for example. The user has full control
over the application (OPENweb, OPENenergy, etc.) and data.
We will be happy to prepare an individual offer including additio-
DEOS OPEN IT
nal or other solutions for you. Cloud service
Solutions portal
The DEOS Cloud Solutions also include planning support, deve-
lopment of security concepts as well as its maintenance by DEOS
in-house IT staff, with the necessary proximity to and experience
in the core business of DEOS AG – building automation.
OPEN IT
Through the DEOS solution for networked locations in conjunc- IT expert
tion with the DESO Cloud Solutions, we offer you and your cus- security
services
tomers the opportunity to always maintain an overview of the sta- services
tuses of your buildings – such as branches, subsidiaries or entire
properties as well as office, hotels, schools and kindergartens,
etc. Your powerful building automation systems have never been
this secure or networked.

Firewall

Secure VPN
connections
DEOS AG data center with
central server environment,
backup, etc. for IT and BMS
applications

Internet

Secure
Secure VPN connections Various IT networks in the
mobile
properties
access

100 C 2018 - Technical changes excepted. Pictures similar.


NEU
Cloud Solutions Accessories
NEW

Article Type Art.-No.


VPN firewall/router hardware for connecting to the DEOS Cloud DS-C-VPNRED DS-360172
• Initial costs per connected site/installation
• Set-up fee for the VPN connection
• Connection of the location/installation to the DEOS Cloud
• Internet access required
• WAN-side IP is obtained via DHCP
• Ports TCP 3400 + UDP 3410 outgoing must be open
Individual firewall configuration according to your requirements DS-C-Firewall DS-360173
We are happy to support you in project planning and implementation!
Basic access to SSL VPN web portal or VPN dial-in DS-C-ServPortal DS-360174
• Clientless SSL VPN via your web browser
• VPN client dial-up (operation via ControlPanel)
• Up to three users
• Only in connection with DS-C-VPNRED
Group for system partners DS-C-SPGruppe DS-360175
• All service technicians of the system partner will be collected
in a group
• The group has access to all the system partner‘s installations
and only uses one user for each service portal
• Booking per service technician in the group
• Not for end customers!
Provision of a virtual computer to operate an OWB2 DS-C-vPC-250 DS-360176
• Virtual computer on the basis of Windows 10
• 4 GB vRAM, 70 GB vHDD, 2 vCPUs
• Daily backup of the virtual computer (preset time 5 days)
• Can be installed on an OPENweb server with max 250 DP
• Operation of your installation per OPENweb ControlPanel /

Accessories
OPENview ControlPanel
• Can only be used by one user at a time
• OPENweb license not included! Virtual license required (DS-
OWB.Z)!
Provision of a virtual computer to operate an OWB5 DS-C-vPC-500 DS-360177
• Virtual computer on the basis of Windows 10
• 4 GB RAM, 70 GB vHDD, 2 vCPUs
• Can be installed on an OPENweb server with max 500 DP
• Daily backup of the virtual computer (preset time 5 days)
• Operation of your installation per OPENweb ControlPanel /
OPENview ControlPanel
• Can only be used by one user at a time
• OPENweb license not included! Virtual license required (DS-
OWB.Z)!
Provision of a virtual server to operate an OPENweb DS-C-vServer-STD DS-360178
• Virtual server based on Windows Server 2016
• 8 GB vRAM, 70 GB vHDD, 2 vCPUs
• Installation of an OPENweb server with max 2500 DP recom-
mended
• Daily backup of the virtual server (preset time 5 days)
• Prepared for the monitoring of installations and communica-
tion (DS-C-Check)
• Operation of your installation per OPENweb ControlPanel
OPENview Control Panel
• Can only be used by one user at a time
• OPENweb license not included! Virtual license required (DS-
OWB.Z)!

C 2018 - Technical changes excepted. Pictured products similar. 101


NEU
Accessories NEW
Cloud Solutions

Article Type Art.-No.


Provision of a virtual server to operate an OPENweb DS-C-vServer-ADV DS-360179
• Virtual server based on Windows Server 2016
• 12 GB vRAM, 100 GB vHDD, 2 vCPUs
• Installation of an OPENweb server with max 5000 DP recom-
mended
• Daily backup of the virtual server (preset time 5 days)
• Prepared for the monitoring of installations and communica-
tion (DS-C-Check)
• Operation of your installation per OPENweb ControlPanel
OPENview Control Panel
• Can only be used by one user at a time
• OPENweb license not included! Virtual license required (DS-
OWB.Z)!

Additional working memory (per 2 GB vRAM) DS-C-vRAM DS-360180


• For virtual computer & server

Additional CPU (per vCPU) DS-C-vCPU DS-360181


• For virtual computer & server

Additional hard disk space (per 50 GB vHDD) DS-C-vHDD DS-360182


• For virtual computer & server

E-mail notification DS-C-Mail DS-360183


• Provision of an E-mail server (SMTP server) for fault signal
removal with the event server of the OPENweb
• Any number of E-mails included

SMS notification DS-C-SMS DS-360184


• Provision of an SMS server for fault signal removal with the
event server of OPENweb
• 20 SMS/months included
• 9 ct/ SMS as of 21st message
• Up to three received call numbers

Virtual operator station on the basis of Windows 10 DS-C-BedVM DS-360185


• Initial costs per VM operator station
• Operation of your installation per OPENweb ControlPanel
OPENview Control Panel
• Can only be used by one user at a time

Virtual terminal server on the basis of Windows server DS-C-BedTerm DS-360186


• Initial costs per assigned user on the terminal server
• Operation of your installation per OPENweb ControlPanel
OPENview Control Panel
• Can be used by several users at the same time
• At least 5 or more users

102 C 2018 - Technical changes excepted. Pictures similar.


NEU
Cloud Solutions Accessories
NEW

Article Type Art.-No.


Monitoring of your installation for accessibility DS-C-Check DS-360187
• Notifications by E-mail in the event of failures
• Monitoring of the individual network participants
• Up to 50 participants are monitored
• Participants must respond to the PING
• List of IP addresses of the participants is provided by the
system partners

SMS notification for DS-C-Check DS-C-Check-SMS DS-360188


• SMS notification in the event of failures
• 20 SMS/months included
• 9 ct/SMS as of 21st message
• Up to three received call numbers
• Only German message destinations allowed

Status website for DS-C-Check DS-C-Check-Web DS-360189


• Provision of the monitoring as own website within the VPN
network

Service by Cloud technicians DS-C-Service DS-360190


• For special configurations not included in the set-up costs
• For hotline activities outside the DEOS AG service hours, we
charge per 15 minutes or part thereof

Accessories
For all DEOS Cloud Solutions articles:
Minimum contractual period: 36 months
Notice period: 3 months
Automatic renewal: 12 months
Method of payment: annually in advance

We are happy to offer you individual IT solutions on request

Send your request to or call us at


* it@deos-ag.com ( +49 5971 91133-3333

C 2018 - Technical changes excepted. Pictured products similar. 103


Accessories General

Article Type Art.-No.


Ordering information
for modem connection cable:
Please specify when ordering, if the modem will be operated
on the OPEN EMS system, BASICline system or on the PC.
A corresponding cable will be atributed.

Connection to sytem required connecting cable


OPEN EMS DS-RJ45DK9DE
Basicline DS-C500MOD
PC DS-RS232mf1:1

Analog modem with RS 232 interface for DIN mounting, DS-MOD A 106 DS-350048
incl. connecting cable

Feed in via screw terminals or socket-type power supply.


The modem can be used for the systems OPEN EMS,
BASICline or at PCs. The modem features FAX Class 2 and
fax messages can be transmitted in combination with
OPEN EMS and BASICline.
The modem features automatic and manual reset functions
which can be initiated via the internal button or via an external
contact.

Voltage supply 10 .. 30 V DC
Current consumption 24 V DC / approx. 60 mA in standby
Dimensions (WxHxD) 106 x 98 x 60 mm

Please note the ordering information on this page !

Delivery w/o power supply unit


Accessories:
Power supply unit DS-MODNTZ125

ISDN modem with RS 232 interface for DIN mounting, DS-MOD I 106 DS-350049
incl. connecting cable

Feed in via screw terminals or power supply.


The modem can be used for the systems OPEN EMS,
BASICline or at Pcs.
The modem features automatic and manual reset functions,
which can be initiated via the internal button or via an external
contact.

Voltage supply 10 .. 30 V DC
Current consumption 24 V DC / approx. 60 mA in standby
Dimensions (WxHxD) 106 x 98 x 60 mm

Please note the ordering information on this page !

Delivered w/o power supply unit


Accessories:
Power supply unit DS-MODNTZ125

104 C 2018 - Technical changes excepted. Pictures similar.


General Accessories

Article Type Art.-No.


GSM radio modem small with RS232 interface DS-MODGSM3 DS-350020

for DIN rail mounting, incl. modem adapter.


Voltage supply 10 .. 24 V DC
Dimensions (WxHxD) 23 x 75 mm x 110 mm
The modem is able to work with quad band.

This modem cannot be operated in combination with a battery


set (DS-SNT 4028 and DS-LCR12), as the charge voltage
is 27.6 V.
For operating the modem, the antenna DS-GSMANT3 is
required.
The initialising sequence must be changed.
The initialising sequence „Z“ must be removed as with the
sequence „Z“ active, an existing communication will be inter-
rupted. Further to this, GSM mode in the controller must be
set to „2“.
For the system BASICline the modem can be used from cont-
roller bus version 2.42 and up (controller version 9.200).

Caution:
The voltage rating is specified by 10..24 V DC.
Therefore, the modem should be operated with the power
supply unit Type: DS-MODNTZ125.

Note:
We recommend this device for sending alarm messages via
SMS or OPENweb as the availability of fixed telephone servi-
ces (TAP, UCP) is only limited.
Due to the low bandwidth is a remote access (remote control,

Accessories
remote loading, ...) only partially possible.*

- Delivery w/o antenna


- Delivery w/o plug-in power supply unit

Accessories:
- antenna with magnetic base plate DS-GSMANT3
- Power supply unit DS-MODNTZ125

Note for ordering:


When ordering, indicated whether the modem shall be used at
system OPEN EMS, at BASICline or at PC. The appropriate
connecting cable will then be included.

*According to press releases, various GSM service provider


have announced a regional break of the CSD data service.
If the CSD data service is not available the option remote
maintenance does not work. Relaying of messages via SMS
or OPENweb is not affected. Therefore, we recommend this
device only for sending messages via SMS or OPENweb.

C 2018 - Technical changes excepted. Pictured products similar. 105


Accessories General

Article Type Art.-No.


Power supply unit 230 V AC DS-MODNTZ125 DS-350065
for OPEN modem types:

• DS-MOD A 106
• DS-MOD I 106
• DS-MODGSM3

Output: 12 V, DC 1,25A

Note for ordering:


Info regarding the use of the power supply for which
OPEN modem must be included.

Multiband antenna with magnetic base plate DS-GSMANT3 DS-350021


GSM radio modem DS-MODGSM3
Antenna length: 9 cm
Cable length: 2.5 m
Frequency range: 900/1800 MHz
Gain: 0 db

106 C 2018 - Technical changes excepted. Pictures similar.


General Accessories

Article Type Art.-No.


Power supply with controlled output DS-PS 24-0.42 DS-350160

Input voltage 85 .. 264 V AC


Output voltage 24 V DC
Output current 0,42 A DC
Short-circuit proof
Operation LEDs green - DC Ok
red - DC Low
Protection class IP20
Mounting Standard DIN rail 35 mm
Dimensions (WxHxD) approx. 29 x 910 x 57 mm

Power supply with controlled output DS-PS 24-1.25 DS-350161

Input voltage 85 .. 264 V AC


Output voltage 24 V DC
Output current 1,25 A DC
Short-circuit proof
Operation LEDs green - DC Ok
red - DC Low
Protection class IP20
Mounting Standard DIN rail 35 mm
Dimensions (WxHxD) approx. 53 x 91 x 57 mm

Power supply with controlled output DS-PS 24-2.50 DS-350162

Accessories
Input voltage 85 .. 264 V AC
Output voltage 24 V DC
Output current 2,50 A DC
Short-circuit proof
Operation LEDs green - DC Ok
red - DC Low
Protection class IP20
Mounting Standard DIN rail 35 mm
Dimensions (WxHxD) approx. 71 x 91 x 57 mm

Power supply with controlled output DS-PS 24-4.20 DS-350163

Input voltage 85 .. 264 V AC


Output voltage 24 V DC
Output current 4,20 A DC
Short-circuit proof
Operation LEDs green - DC Ok
red - DC Low
Protection class IP20
Mounting Standard DIN rail 35 mm
Dimensions (WxHxD) approx. 90 x 91 x 57 mm

C 2018 - Technical changes excepted. Pictured products similar. 107


Accessories General

CAN-bus wiring Rules for CAN-bus wiring


Specifications for cables in a CAN-bus network are defined
• When wiring a CAN net, observe applicable rules and
in ISO 11898.
directives (DIN, VDE, etc.) as to cable routing, cross-
section, selection of material, electromagnetic compat-
Cable design
ibility, lightning and overvoltage protection, etc.
Cable Min. 2 wire twisted, plus shield
• A CAN cable must have two twisted wires for signal
Topology Line - bus
transmission (CAN-high, CAN-low) and another wire for
Terminal resistor both ends 120 Ohm each,
the reference potential (CAN-ground). Common practise is
(impedance level)
to use the cable shield for this purpose.
Characteristic electric data:
• When laying cables between two buildings, a separate
shield is required. Therefore, use double-shielded cables
Impedance level 120 Ohm
or conduct the reference potential (CAN-ground) via an
specific signal run time max. 5 ns/m
additional wire (2x2 wired shielded cables).
Max. cable lengths and cross-section:
• At one point, the reference potential CAN-ground must be
connected to the ground potential (PE).
max. min. max.
length cross-section baud-rate
• Bus cables should not be passed in the environment of
m mm² kbit/s
sources for interference. If local conditions do not permit
this, use double-shielded cables.
25 0,34 1000
50 0,34 500
• A CAN-bus must not branch out and must be terminated at
100 0,34 250
both ends using impedance resistors.
250 0,5 125
500 0,5 50
• Branch lines has to be kept as short as possible
1000 0,75 20
• ( s < 1 m).
2000 1,0 10
5000 1,5 10
• The selected baud rate must not exceed the maximum
permissible baud rate for the selected cable (refer to table
on the left).
Achievable bus lengths eventually depend on the local con-
ditions (cable, number of users, interference, ...) for the re-
• Selected cross-section should be generous in reference to
levant object. Appropriate safety factors and margins should
the bus length.
be considered when planning layout and physical installation.

If in doubt, a lower baud rate can be selected, or the bus can


be split into two independent lines (e.g. OPEN 3100 EMS:
CAN 1 and CAN 2).

The maximum available cable length won´t be enlarged by


using CAN repeaters.

Recommendation for cables

You may use any cables which meet the above criteria.
When selecting a particular cable, the local conditions and
circumstances should be considered (ambient temperature,
humidity, interference, fixed or flexible installation, etc.)!

108 C 2018 - Technical changes excepted. Pictures similar.


General Accessories

Article Type Art.-No.


CAN-bus cables
for permanent indoor installations

General
Inner conductor Copper, blare
Conductor isolation Foam skin PE
Conductor colors CAN-bus white, brown
Conductor colors net black, blue
Stranded element double wire
Shield Polyester film
around strand compound
Overall shield Cu meshwork vz
Outside color violet, similar to RAL 4001

Technical data
Impedance level 120 Ohm +/- 10%
Isolation resistance 1,00 GOhm x km min.
Temperature range
Operating temp. min. -20 °C
Operating temp. max. +70 °C

Standards
Applicable standards DIN 19245 T3 and EN50170
UL-Style UL-Style 2571
CAN-bus cable DS-BUS-C0,34 DS-350024
Cross-section CAN-bus 1 x 2 x 0,34 mm²
Outer cable diameter 6,5 mm +/- 0,3
Operational capacity 58 pF/m nom.

Accessories
CAN-bus cable DS-BUS-C0,5 DS-350036
Cross-section CAN-bus 1 x 2 x 0,5 mm²
Outer cable diameter 7,0 mm +/- 0,3
Operational capacity at 800 Hz 37 pF/m nom.
CAN-bus cable DS-BUS-C0,75 DS-350025
Cross-section CAN-bus 1 x 2 x 0,75 mm²
Outer cable diameter 8,4 mm +/- 0,3
Operational capacity at 800 Hz 36 pF/m nom.
CAN-bus cable DS-BUS-C0,5-N1,5 DS-350047
with integrated 24 V DC network cable channel
Cross-section, net line 2 x 1,5 mm²
Cross-section CAN-bus 1 x 2 x 0,5 mm²
Outer cable diameter 9,7 mm +/- 0,3 mm
Operational capacity at 800 Hz 37 pF/m nom.

Note:
Cable prices are based on a Cu material value of
150 Euro / 100 kg. For specific orders, the surcharge for the
metal is calculated acc. to the DEL quotation at the time of
order placing.

C 2018 - Technical changes excepted. Pictured products similar. 109


Accessories General

Article Type Art.-No.


Halogen-free CAN-bus cables
for permanent indoor installations

General
Inner conductor Copper, blare
Conductor isolation Foam skin PE
Conductor colors CAN-bus white, brown
Conductor colors net black, blue
Stranded element double wire
Shield Polyester film
around strand compound
Overall shield Cu meshwork vz
Outside color violet, similar to RAL 4001

Technical data
Impedance level 120 Ohm +/- 10%
Isolation resistance 1,00 GOhm x km min.
Temperature range
Operating temp. min. -20 °C
Operating temp. max. +70 °C

Standards
Applicable standards DIN 19245 T3 and EN50170

CAN-bus cable DS-BUS-C0,5-H DS-350085


halogen-free
Cross-section CAN-bus 1 x 2 x 0,5 mm²
Outer cable diameter 7,0 mm +/- 0,3
Operational capacity at 800 Hz 37 pF/m nom.
CAN-bus cable DS-BUS-C0,75-H DS-350086
halogen-free
Cross-section CAN-bus 1 x 2 x 0,75 mm²
Outer cable diameter 8,4 mm +/- 0,3
Operational capacity at 800 Hz 36 pF/m nom.
CAN-bus cable DS-BUS-C0,5-N1,5-H DS-350087
halogen-free
with integrated 24 V DC network cable channel
Cross-section, net line 2 x 1,5 mm²
Cross-section CAN-bus 1 x 2 x 0,5 mm²
Outer cable diameter 9,7 mm +/- 0,3 mm
Operational capacity at 800 Hz 37 pF/m nom.

Note:
Cable prices are based on a Cu material value of
150 Euro / 100 kg. For specific orders, the surcharge for the
metal is calculated acc. to the DEL quotation at the time of
order placing.

110 C 2018 - Technical changes excepted. Pictures similar.


General Accessories

Article Type Art.-No.


Bus line, RS485 DS-BUS-R DS-350023
for permanent indoor installations

General
Cross-section 2 x 0,52 mm²
Outer cable diameter 5,04 mm +/- 0,4
Inner conductor copper, tin-plated
Conductor isolation Polyethylen 2Y 11
VDE 0819 Part 103
Conductor colors black, transparent
Stranded element double conductors
(2 x0,52 mm²)
Shield AluPoly-foil, metal side
outside with tin-plated
drain wire 1 x 0,32 mm²
Outside color grey, RAL 7001

Technical data
Impedance level 100 Ohm +/- 10 %
Isolation resistance min. 1,00 MOhm x km
Conductor resistance max. 39,0 Ohm / km
Conduit PVC TM2
according VDE 0281 Part 1
Temperature range
Operating temp. min. -30 °C
Operating temp. max. +70 °C

Accessories

Note:
Cable prices are based on a Cu material value of
150 Euro / 100 kg. For specific orders, the surcharge for the
metal is calculated acc. to the DEL quotation at the time of
order placing.

C 2018 - Technical changes excepted. Pictured products similar. 111


Accessories General

Article Type Art.-No.


Ordering information:
The serial port cables are ordered separately and according to
the purpose

Notes:

• The COM-Port mapping tools may only be installed in


the PC operating.
• When installing an EIB gateway (KNX gateway) you have to
use the connection cable DS-RS232mf1:1.
• The TCP/IP controller cannot be used for BACnet® MS/TP.

TCP/IP controller – industrial version DS-SSU IA5150 V1.3 DS-350100


Interface converter from 1 x RS232 / RS485
to Ethernet

The TCP/IP controller expands the OPEN EMS controller


according to the used model with an additional external COM
Port 5 - 6 or 5 - 8.
The TCP / IP controller can be operated directly at the PC as
external COM-Port.

Features:
• Industrial version.
• 2 Ethernet Ports 10/100 auto MDI/MDIX RJ45
(integrated switch)
• DIN – wall mounting
• Connection via screw terminals
• Redundant power supply possible
• Diagnostic LED´s
• Windows driver for virtual COM Port for
Win7 x86/x64 and Server 2008
• Connection of the supply voltage via screw terminal
• 12 – 48 V DC; 195mA at 24 V
• Alarm message via contact
• Internal buzzer and E-Mail
• Watchdogtimer (Reboot Trigger)
• Configuration directly via Web interface.
• No configuration software for operation
on OPEN EMS will be necessary.

Included in the delivery:


1 x TCP/IP Controller
1 x Support-CD
1 x operating instructions
1 x Null-Modem-Adapter

TCP/IP controller – industrial version DS-SSU IA5150I DS-350167


Interface converter from 1 x RS232 / RS485 to Ethernet with
galvanically isolated RS485 interface.

We recommend the use of an RS485 interface, galvanically


decoupled, to minimize possible interferences during system
operation.
Further technical data same as DS-SSU IA5150 V1.3.

112 C 2018 - Technical changes excepted. Pictures similar.


General Accessories

Article Type Art.-No.


Ordering information:
The serial port cables are ordered separately and according to
the purpose

Notes:

The COM-Port mapping tools may only be installed in the PC


operating.

The TCP / IP controller cannot be used for BACnet® MS/TP.

TCP / IP Controller DS-SSU DE311 V3.0 DS-350101


Interface converter from 1 x RS232 / RS485
to Ethernet

Connection compatible replacement for the articles


DS-SSU TCP/IP2 and DS-SSU TCP/IP3

The TCP / IP controller expands the OPEN EMS controller


according to the used model with an additional external COM
Port 5 - 6 or 5 - 8.

The TCP / IP controller can be operated directly at the PC as


external COM-Port.

Accessories
Features:
• 1 Ethernet Port 10/100 auto MDI/MDIX RJ45
• Windows driver for virtual COM Port
for XP/Vista/2003/2008 x86/x64
• Operation via power supply unit
(9 – 30 V DC). 150 mA at 24 V

Included in the delivery:


1 x TCP / IP Controller
1 x Support-CD
1 x operating instructions
1 x Null-Modem-Adapter
1 x external power supply unit

C 2018 - Technical changes excepted. Pictured products similar. 113


Accessories General

Article Type Art.-No.


Field socket with screw connection DS-SUBCON9/F DS-024023
SUB-D9-pole socket

Interface converter, RS232 to 20mA, DS-SSURS232/TTY DS-140410


active or passive current loop TTY
switch cabinet module with electr. isolation
max. distance between 2 devices: 1000 m
Connection via connectors 0.2-2.5 mm² or SUB-D
connectors, 9-pole
Voltage supply: 24 V AC /DC +/- 20%
Mounting on DIN rail
Interface converter, RS232 to RS485, DS-SSURS232RS485 DS-360069
switch cabinet module with electr. isolation,
max. distance between 2 devices: 1000 m,
Connection via connectors 0.2-2.5 mm² or
SUB-D connectors, 9-pole
Voltage supply: 24 V AC /DC +/- 20%
Mounting on DIN rail
incl. connecting cable RJ45DK9DE

114 C 2018 - Technical changes excepted. Pictures similar.


General Accessories

Article Type Art.-No.


Connecting cable OPEN EMS DS-RJ45DK9DE DS-024081

Interface cable RS 232


OPEN EMS - peripheral unit
RJ45 plug on SUB-D 9-pin plug, length of 1.5 m
Application: Modem, M-Bus ...

Connecting cable OPEN EMS DS-RJ45DK9PC DS-024082

Interface cable RS 232


OPEN EMS - PC
RJ45 plug on SUB-D 9-pin olug, length of 1.5 m
Application: EIB-seperating filter (EIB-01) PC / Laptop

CAN Repeater DS-CANRepO DS-350040

The CAN repeater can be used to improve the signal


quality and capacity of the CAN-bus or to create
an electric isolation between sections of the CAN-bus.
Voltage supply: 24 V DC

PC USB to CAN Interface, DS-USB-CAN DS-024084


Converter from PC USB to CAN-bus,

Accessories
incl. 4m connecting cable for the CAN-bus

Spare battery DS-Bat OPEN EMS DS-024095


for the following controllers

• OPEN 500 EMS


• OPEN 600 EMS
• OPEN 710 EMS
• OPEN 810 EMS
• OPEN 3100 EMS
• OPEN 4100 EMS
Spare battery DS-Bat OPEN COS DS-024100
for the following controllers

• COSMOS 700 OPEN


• COSMOS 800 OPEN
• COSMOS 3000 OPEN
• COSMOS 4000 OPEN
Spare battery DS-Bat B DS-024076
for the following controllers

• COSMOS BASICline

C 2018 - Technical changes excepted. Pictured products similar. 115


Accessories General

Article Type Art.-No.


Network switch DS-SW5 DS-360005
5-Port 10 / 100 Mbit
5 x RJ45 ports 10 / 100 Mbit
128 KB buffer memory
with external power supply unit
Network switch DS-SW8-230 DS-360059
8-Port 10 / 100 Mbit
8 x RJ45 ports 10 / 100 Mbit
128 KB buffer memory
with external power supply unit (connection 230 V AC)
Network switch DS-2030B-A DS-360020
3 port switch
3 x 10/100 Base-T(X)
Protection: IP30
Voltage supply: 9 V to 60 V DC
Dimensions: (HxWxD) 113,5 x 46,5 x 27,3 mm
Operation temperature: 0°C to +55°C

Network switch DS-2050B-A DS-360021


5 port switch
5 x 10/100 Base-T(X)
Protection: IP30
Voltage supply: 9 V to 60 V DC
Dimensions: (HxWxD) 113,5 x 46,5 x 27,3 mm
Operation temperature: 0°C to +55°C

Network switch DS-2080B-A DS-360022


8 port switch
8 x 10/100 Base-T(X)
Protection: IP30
Voltage supply: 9 V to 60 V DC
Dimensions: (HxWxD) 113,5 x 60 x 27,3 mm
Operation temperature: 0°C to +55°C

Network switch DS-2160B-A DS-360023


16 port switch
16 x 10/100 Base-T(X)
Protection: IP30
Voltage supply: 9 V to 60 V DC
Dimensions: (HxWxD) 113,5 x 120 x 27,3 mm
Operation temperature: 0°C to +55°C

RJ 45 connector socket for DIN rail mounting DS-RJ45H DS-360019


Connector unit with 1 x E-DAT module 8(8) Cat.6 for mounting
on DIN rail TH35 to DIN EN60715.
A cover at the E-DAT module prevents direct skin contact.
When using the unit with protection class I, equipotential
bonding is effected via an integrated potential compensation
spring directly via the DIN rail which via contact terminals must
be connected to the building’s equipotential bonding.

Converter USB 2.0 to RS232 DS-USB-RS232 DS-024061


USB B socket to 9- and 25 pol D-SUB-connectors

116 C 2018 - Technical changes excepted. Pictures similar.


General Accessories

Article Type Art.-No.


Network cable

CAT6 S/FTP patch cable, grey, total screening mesh


& aluminium film shield each pair, 4x2 AWG 26/7, 100 Ohm
2x RJ45 plug with pointed anti-kink sleeve
CAT6 S/FTP patch cablel, grey, 0.5 m long DS-Patch cable05 DS-350061
CAT6 S/FTP patch cablel, grey, 1 m long DS-Patch cable1 DS-350060
CAT6 S/FTP patch cablel, grey, 2 m long DS-Patch cable2 DS-350002
CAT6 S/FTP patch cablel, grey, 3 m long DS-Patch cable3 DS-350003
CAT6 S/FTP patch cablel, grey, 5 m long DS-Patch cable5 DS-350004
CAT6 S/FTP patch cablel, grey, 7.5 m long DS-Patch cable7,5 DS-350079
CAT6 S/FTP patch cablel, grey, 10 m long DS-Patch cable10 DS-350005
CAT6 S/FTP patch cablel, grey, 15 m long DS-Patch cable15 DS-350080
CAT6 S/FTP patch cablel, grey, 20 m long DS-Patch cable20 DS-350012
CAT6 S/FTP patch cablel, grey, 30 m long DS-Patch cable30 DS-350013

Adapter CROSSOVER DS-CR-ADP DS-350102

Crossover-adapter UTP, red


RJ45 plug / socket

Accessories
By attaching the crossover-adapter every CAT6 network cable
becomes a crossover cable.

C 2018 - Technical changes excepted. Pictured products similar. 117


Notice

118 C 2018 - Technical changes excepted. Pictures similar.


Building Management
Building Management / Programming Tools Page
OPENenergy 120
OPENweb Information 125
Building Management
OPENweb basic package 127
Programming Tools
OPENweb expansion modules 128
OPENweb BACnet® expansion modules 130
OPENweb App 131
OPENview 132
OPENview App 132
FUP XL - function plan - programming tool 134
MacLib - HVAC Macro Library 135

C 2018 - Technical changes excepted. Pictured products similar. 119


OPENenergy Building Management

OPENenergy

OPENenergy is an energy management software for recor-


ding, analysing and monitoring meter readings and trend data.
It is possible to visualize time series (for example temperatu-
res) and meter readings together.

The system is based on a client-server structure, which enab-


les a non-centralized data access by using a desktop client.

During the data capturing, the imported data points are


automatically connected with the individually extendable unit
conversion system. Through linking the scaled values a wide
range of possibilities for data analysis is set.

The dashboard enables a clear and esthetically pleasing


visualization of selected plant parameters. As such, important
values can be highlighted so that they are immediately visible
at the first glance.

OPENenergy has a selection of pre-configured reports such


as yearly, monthly and weekly reports that can be presented in
tabular or in graphical formats.

With Jaspersoft Studio, OPENenergy offers a powerful graphi-


cal development environment for customized design reports.
Furthermore, external applications can gain directly access to
the report database via Excel-exports.

Every meter and trend data, which are connected to the


OPEN, can be read out by the trend data interface.

120 C 2018 - Technical changes excepted. Pictures similar.


Building Management OPENenergy

OPENenergy – program functionalities

The software includes the following functions:

• trend data processing


• customizable dashboard
• excel export
• time zone support
• change log
• customizable unit system
• reporting
• manual meter reading
• ignoring of wrong meter readings
• configuration of meter exchanges
• limit value monitoring via e-mail
• automatical transmission of reports
• Individual tree structure
• Report preset and gadget preset
• Dashboard presenter
• Automatic client update
• User management
• Parameter data base

________________________________

ISO 50001

The energy management norm ISO 50001 is the first worldwi-


de valid norm to specify the implementation and maintenance
of energy management systems, which aims at an efficient
use of resources. It defines all requirements for companies
and emphasizes compliance and optimization of the com-
panies´ energy politics. By establishing responsibilities and
defining time- and action plans, a continuous optimization of
the building performances is guaranteed.

To achieve this optimization, the norm suggests a plan-do-act- Continual


check rhythm. DEOS actively supports companies for imple- improvement
Energy policy
menting an energy management system according to the ISO
50001.
Management- Energy planning
OPENenergy serves as a central platform for the automatic Review
Building Management
monitoring and evaluation of energy flows and contributes Programming Tools
towards successful energy optimization.
Implemention
and operation

Monitoring,
Checking measurement,
analysis

Nonconformities,
Internal audit corrective and
of the ENMS preventive action

C 2018 - Technical changes excepted. Pictured products similar. 121


OPENenergy Building Management


Article Type Art.-No.
OPENenergy DS-OE25 DS-371226
licenced for 25 data points1
OPENenergy DS-OE50 DS-371227
licenced for 50 data points1
OPENenergy DS-OE100 DS-371228
licenced for 100 data points1
OPENenergy DS-OE150 DS-371253
licenced for 150 data points1
OPENenergy DS-OE200 DS-371229
licenced for 250 data points1
OPENenergy DS-OE500 DS-371230
licenced for 500 data points1
OPENenergy DS-OE750 DS-371254
licenced for 750 data points1
OPENenergy DS-OE1000 DS-371231
licenced for 1000 data points1
OPENenergy DS-OE2000 DS-371232
licenced for 2000 data points1
OPENenergy DS-OE5000 DS-371233
licenced for 5000 data points1
OPENenergy DS-OE00 DS-371234
licenced for unlimited data points1
New activation of an OPENenergy License DS-OE.Y DS-371259

A new activation is required in case of

• moving OPENenergy to another hardware or virtual machine


(VM)
• changing the operating system of the OPENenergy environment
OPENenergy Upgrade DS-OE.UP DS-371260
Upgrade of the energy management software OPENenergy to
the next full version.
OPENenergy reports
Generation and adjustment of customized reports

Software support and hotline contract

Delivery contents include updates and hotline-support

Note:
• The hotline support requires a previous participation in the
training for OPENenergy and/or Jaspersoft-Studio.

General information:
• The efforts required for installation and commissioning of
OPENenergy depend on the projects.
• The sotware doesn´t include hardware, such as server pc,
interface cards, modem etc.

1
Note: In the field of building automation a data point marks an input or output function. There are physical and virtual
data points. Meters may contain several data points.
122 C 2018 - Technical changes excepted. Pictures similar.
Building Management Notice

Building Management
Programming Tools

C 2018 - Technical changes excepted. Pictured products similar. 123


OPENweb Building Management

OPENweb
allows a web-based Building Management-Software (BMS) for
operating, monitoring, parameterization and extensive alarm
management of control and regulation devices (controller).
The presentation of the information is transmitted via standard
browser or via OPENweb ControlPanel.

A touch screen able navigation is possible via installation gra-


phics as well as via tree structure. The manufacturer indepen-
dent communication will be done via the BACnet extension.

Following modules are included in the basic package:

ECC Basic
The Event Control Center in basic version is the central
software for displaying and processing of all alarms and all
messages.

Log book
• Logging of user interventions.
• Recording of parameter changes at OPENweb platform with
date, time, old and new value.
• Logging of user logins and logouts with date, time and user-
name.

Trend log
• Historicization of trend data when change in value
• Free definable polling interval of each data point
• Auto calling to decentralized OPEN EMS controller

Trend visualization
• Graphical visualization of trend data
• Unlimited number of trends in each diagram
• Free selection of trend data of various controller
• Free parameterization of the ordinates of each trend chart
• Formula administration, pre-parameterized trend data
selection
• Visualization of actual values at one time, possibility of
comparison
• Zoom function for clear visualization of range view
• Print function
• CSV-export for processing with external programs, e.g. Excel

Modem module1
For operating and monitoring of decentralized controller via
telecommunication network, DSL, Internet

1 For the use of this functions you need the technical services of the network
operator. DEOS products will no longer support the transmission of SMS mes-
sages via modem. Services that are still actively working may stay in function.

124 C 2018 - Technical changes excepted. Pictures similar.


Building Management OPENweb

Graphical process visualization


• Displaying of installation graphics with graphical objects for
visualization of set- actual / measured and event data as
pictures, slider, progress bar, texts lines, color objects
• Supported graphic formats: vector graphics WMF and SVG,,
JPG, PNG, GIF, animated GIF
• Process-oriented rotation, flashing, positioning and resizing
of graphic objects
• Auto zoom function: auto scaling of the installation graphics
to corresponding resolution
In addition to the scope of delivery for the basic package, the
functionality of OPENweb can be expanded using the fol-
lowing modules.

E = Event server
A = Event Control Center
S = SQL - Module
O = OPC - Module
BAC.F = Fidelio Hotel booking system
BACx = BACnet expansion

Order example:

DS-OWB2
OPENweb basic package with 250 data points

DS-OWB2.S
OPENweb basic package with 250 data points and
SQL module

DS-OWB10.E
OPENweb basic package with 1.000 data points and
event server

DS-OWB2.E.BAC5
OPENweb basic package with 250 data points, event client
and expansion module native BACnet with up to 500 BACnet
objects Building Management
Programming Tools
Note:
When ordering a BACnet expansion module, the number of
OPENweb data points does not necessarily be the same as
the number of BACnet objects.

The scope of delivery for OPENweb does not include hard-


ware, such as server PC, interface cards, modem, etc.

C 2018 - Technical changes excepted. Pictured products similar. 125


OPENweb Building Management

OPENweb Licensing

To simplify and accelerate upgrades and expansions for the


BMS software OPENweb, a new license model was imple-
mented in version 7.0.

The basic license for OPENweb will be done via a hardware


dongle or an OPENweb VM-license. The dongle version will
be always delivered by default. For the delivery of an OPEN-
web VM-license, the corresponding option OWB.Z (see page
127) has to be ordered. Basic packages and expansion
modules are activated via a license file.

Once OPENweb has been ordered, you will receive a hard-


ware dongle with a serial number or a software-key (OPEN-
web VM-license) and a license file. OPENweb runs only in
connection with the license file, the hardware dongle or the
OPENweb VM-license.

For an increase of data points afterwards in OPENweb and


/ or the addition of an OPENweb expansion module, only a
license file will be sent out and needs to be replaced.

The serial number (SN) of the hardware dongle is required for


upgrades and expansions of OPENweb. Please indicate the
serial number when placing your order.

Note:
The redemption of the data points and / or OPENweb expan-
sion modules is not possible once the license file has been
delivered.

Article Type Art.-No.


OPENweb Upgrade DS-OWB-UP DS-371208
Upgrade of the BMS software OPENweb to the next
full version.

126 C 2018 - Technical changes excepted. Pictures similar.


Building Management OPENweb

Article Type Art.-No.


OPENweb basic package DS-OWB2 DS-371150
for up to 250 physical data points.
The following modules are included in the basic package:
Log book, trend log and visualization, dynamic visualization
and modem module.
For further details see product description on page 122.

OPENweb basic package DS-OWB5 DS-371151


like OWB2 however
for up to 500 physical data points.

OPENweb basic package DS-OWB10 DS-371152


like OWB2 however
for up to 1.000 physical data points.

OPENweb basic package DS-OWB20 DS-371153


like OWB2 however
for up to 2.000 physical data points.

OPENweb basic package DS-OWB30 DS-371221


like OWB2 however
for up to 3.000 physical data points.

OPENweb basic package DS-OWB40 DS-371222


like OWB2 however
for up to 4.000 physical data points.

OPENweb basic package DS-OWB50 DS-371154


like OWB2 however
for up to 5.000 physical data points.

OPENweb basic package DS-OWB75 DS-371223


like OWB2 however
for up to 7.500 physical data points.

Building Management
OPENweb basic package DS-OWB100 DS-371214
Programming Tools
like OWB2 however
for up to 10.000 physical data points.

OPENweb basic package DS-OWB200 DS-371215


like OWB2 however
for up to 20.000 physical data points.

OPENweb basic package DS-OWB00 DS-371155


like OWB2 however
for unlimited number of physical data points.

C 2018 - Technical changes excepted. Pictured products similar. 127


OPENweb Building Management

Article Type Art.-No.


OPENweb expansion module DS-OWB.E DS-371158
Event server

Software module for relaying of events.


(Alarm and reporting system); as
SMS (TAP, UCP, GSM), E-Mail, Printer
FAX, ASCII and OPENweb

OPENweb expansion module DS-OWB.A DS-371205


Event Control Center
for the management of alarms and messages.

The Event Control Center (ECC) is the central software for


displaying and processing of the alarms and messages. As
an extension of the ECC basic version it provides the ability
to configure user-specific views for the display and therefore
show all relevant information directly to the user. In addition
to the time of recording the acknowledgements, it offers
many more options for filtering and processing of alarms and
messages.

OPENweb expansion module DS-OWB.S DS-371160


SQL-Module

Software module for bi-directional data exchange with other


systems via a SQL database.

OPENweb expansion module DS-OWB.O DS-371161


OPC-Server

Software module for bi-directional data exchange with other


systems via OPC protocol.
OPENweb expansion module DS-OWB.BAC.F DS-371196
BACnet connection
Fidelio Hotel booking system

Software module for linking the Hotel booking system


Fidelio on OPEN EMS via the BACnet protocol.
This module makes the room allocation available such as
Check-In, Check-Out and Pre-Check-In as a BACnet ob-
ject. Each BACnet device in the network can access on this
information. Automatic selection and alignment of the room
allocation on system start.

Note:
For the application of the Hotel booking system additionally a
BACnet expansion module is necessary.

128 C 2018 - Technical changes excepted. Pictures similar.


Building Management OPENweb

Article Type Art.-No.


OPENweb VM-License DS-OWB.Z DS-371224

OPENweb VM-License w/o hardware-dongle for use on ser-


vers w/o USB port

New activation of an OPENweb VM-License DS-OWB.Y DS-371225

A new activation is required in case of

• moving OPENweb to another hardware or virtual machine


(VM)
• changing the operating system of the OPENweb environ-
ment

OPENweb Professional DS-OWB00prof DS-371173


for project planning and a customer service tool.
Complete package OPENweb with all expansion modules and
additional offline parameterizing for data back-up, however,
without BACnet modules. Incl. service and hotline.

Note:
• Participation at the DEOS basic training seminar is required
for the purchase of this software

• OPENweb Professional shall not be used in projects or as


BMS GLT !

Building Management
Programming Tools

C 2018 - Technical changes excepted. Pictured products similar. 129


OPENweb Building Management

Article Type Art.-No.


OPENweb expansion module
native BACnet

Software module for connection of other data points via the


BACnet protocol.
The software module is integrated as a native BACnet driver
into OPENweb. There will be no conversion via other proto-
cols.

Notes:
• For BACnet connection is a OPENweb basic package neces-
sary.
• When ordering a BACnet expansion module, the number of
OPENweb data points does not necessarily be the same as
the number of BACnet objects.

Order example:

DS-OWB2.L.E.BAC5
OPENweb basic package with 250 data points, log book,
event client and expansion module native BACnet with up to
500 BACnet objects

DS-OWB10.BAC2
OPENweb basic package with 1.000 data points and expansi-
on module native BACnet with up to 250 BACnet objects

OPENweb expansion module DS-OWB.BAC2 DS-371163


native BACnet with up to 250 BACnet Objects
OPENweb expansion module DS-OWB.BAC5 DS-371164
native BACnet with up to 500 BACnet Objects
OPENweb expansion module DS-OWB.BAC10 DS-371165
native BACnet with up to 1.000 BACnet Objects
OPENweb expansion module DS-OWB.BAC20 DS-371166
native BACnet with up to 2.000 BACnet Objects
OPENweb expansion module DS-OWB.BAC30 DS-371235
native BACnet with up to 3.000 BACnet Objects
OPENweb expansion module DS-OWB.BAC40 DS-371236
native BACnet with up to 4.000 BACnet Objects
OPENweb expansion module DS-OWB.BAC50 DS-371167
native BACnet with up to 5.000 BACnet Objects
OPENweb expansion module DS-OWB.BAC75 DS-371237
native BACnet with up to 7500 BACnet Objects
OPENweb expansion module DS-OWB.BAC100 DS-371238
native BACnet with up to 10.000 BACnet Objects
OPENweb expansion module DS-OWB.BAC200 DS-371239
native BACnet with up to 20.000 BACnet Objects
OPENweb expansion module DS-OWB.BAC00 DS-371168
native BACnet with unlimited numbers of BACnet Objects

130 C 2018 - Technical changes excepted. Pictures similar.


Building Management OPENweb

Description
The OPENweb app connects to your OPENweb
server and is used to operate and monitor it. The
app allows you to access parameters on your
heating, ventilation and air-conditioning techno-
logy in facility management as well as to light,
shading and temperature in room control.
The same graphic operator pages as in the
browser or with the OPENweb ControlPanel are
displayed so that no additional project work is
necessary.

OPENweb app is available for mobile devices


with the Android operating system as of version
4.x. Operation is optimized for smartphones and
tablets.

The following requirement must be met for opera-


ting an OPENweb server with the OPENweb app:
• OPENweb server as of version 7.11a
Building Management
Programming Tools

Article Type Art.-No.


OPENweb App DS-OW App DS-371250
for Android systems as of version 4.x

Note:
OPENweb App and OPENview App are already installed on
DEOS Tablets and included in the tablet price.

C 2018 - Technical changes excepted. Pictured products similar. 131


OPENview Building Management

Activation of the graphical webserver on


OPEN EMScontroller.

OPENview facilitates the operation and the use of your buil-


ding services installations. OPENview is available with graphic
or text-guided user interface.

The presentation of the information is transmitted via standard


browser or via OPENview ControlPanel.

The text-guided version is standard and as such it is always


activated for use. The graphical version is activated for 6
months, starting at the date of delivery by DEOS AG.
Thereafter, further unlimited licensing must be purchased.

OPENview functions

• displays the project with graphic objects as images, control


lines, columns, text items or colored objects for setpoint and
actual value.

• supports vector graphics in WMF and SVG format.

• automatic size adjustment for all objects to match the current


window (Autozoom).

• process-related size adjustment, flashing, rotating, positio-


ning of objects.

OPENview App
OPENview app allows you to operate and monitor configured
OPEN EMS systems and access parameters on your heating,
ventilation and air-conditioning technology in facility manage-
ment as well as to light, shading and temperature in room
control. OPENview app connects directly to your OPEN EMS.
The same graphic operator pages as in the browser or with
the OPENview ControlPanel are displayed so that no additio-
nal project work is necessary.

OPENview app is available for mobile devices with the Android


operating system as of version 4.x. Operation is optimized for
smartphones and tablets.

The controller groups must meet the following requirements to


operate OPEN EMS with the OPENview app:
• Firmware as of version 1.048e
• OPENview with activated graphic option

Article Type Art.-No.


OPENview App DS-OV App DS-371249
for Android systems as of version 4.x

Note:
OPENweb App and OPENview App are already installed on
DEOS Tablets and included in the tablet price.

132 C 2018 - Technical changes excepted. Pictures similar.


Building Management OPENview

Article Type Art.-No.


OPENview x/0 DS-OV0 DS-371210
Activation of graphical user interface for
the following OPEN controller

• OPEN 600x/0 EMS


• OPEN 500x/0 EMS

OPENview x/5 DS-OV5 DS-371187


Activation of graphical user interface for
the following OPEN controller

• OPEN 600x/5 EMS


• OPEN 500x/5 EMS
• OPEN 810/5 EMS
• OPEN 710/5 EMS
• COSMOS 800/5 OPEN
• COSMOS 700/5 OPEN

OPENview x/12 DS-OV12 DS-371188


Activation of graphical user interface for
the following OPEN controller

• OPEN 810/12 EMS


• OPEN 710/12 EMS
• COSMOS 800/12 OPEN
• COSMOS 700/12 OPEN

OPENview x/32 DS-OV32 DS-371189


Activation of graphical user interface for
the following OPEN controller

• OPEN 810/32 EMS


• OPEN 710/32 EMS
• COSMOS 800/32 OPEN
• COSMOS 700/32 OPEN

OPENview x/C1 DS-OVC1 DS-371190


Activation of graphical user interface for Building Management
the following OPEN controller Programming Tools
• OPEN 4100 EMS C1
• OPEN 3100 EMS C1
• COSMOS 4000 OPEN C1
• COSMOS 3000 OPEN C1

OPENview x/C2 DS-OVC2 DS-371191


Activation of graphical user interface for
the following OPEN controller

• OPEN 4100 EMS C2


• OPEN 3100 EMS C2
• COSMOS 4000 OPEN C2
• COSMOS 3000 OPEN C2

C 2018 - Technical changes excepted. Pictured products similar. 133


FUP XL Programming Tools

Description Technical information


The software licensing option allows you to install Function plan programming software FUP XL
the FUP XL 2, for example, on a customer com- for OPEN EMS, including dongle
puter, use the remote dial-in for remote program
adaptations and to download your new controller • Graphics function plan editor
program onto the OPEN EMS directly at the
• Graphics editor for preparing OPENweb (BMS) visualization
customers.
• Use of libraries for MCR and HVAC systems
From Version FUP XL 2, the programming tool
• MacLib
can be used on a PC optionally with USB dongle
or as virtual software license (VM). • Templates
• Compiler for target system OPEN EMS
• Standard system simulations
• Automatic plausibility check
• Operation via OPENview - the graphical visualization program based
on HTML5 (in full HD resolution)
• Optimized for mobile devices

Article Type Art.-No.


FUP XL1 - function plan programming software, DS-FUP XL1 DS-371174
full version, incl. technical support

Option: FUP XL¹ as a virtual software license (VM) DS-FUP-XL.Z DS-371175


A new order for the FUP XL 2 without dongle requires the FUP XL
(DS-371174) and this additional option.

1
Prerequisite: DEOS Basic Training and the purchase of the software OPENweb Professional

134 C 2018 - Technical changes excepted. Pictures similar.


Programming Tools MacLib

Macro library description Excerpt for application with heating systems


The comprehensive DEOS macro library (MacLib) • Weather-related boiler management (control of burner, 2-stage,
enables the efficient project planning and 0-10 Volt or modulating)
programming of HVAC systems and its OPEN EMS • Hot water boiler incl. anti-legionella programme and charging pump
as well as the BMS in a single step. • Static heating, weather-related management with optimized
switching, RA temperature monitoring and circulating pump
You receive a library with over 900 DEOS macros • Floor heating, weather-related management with optimized switching
from the field of heating, ventilation and refrigeration, and circulating pump
which not only allows you to quickly and easily
program standard systems but comprehensive
Excerpt for application with ventilation systems
systems as well.

The DEOS library includes the complete dynamic • Add-air fan, 2-stage (external control via switch clock, summer nights
and graphic visualization (system images), including cooling or cool-down protection)
the dynamic online documentation. All DEOS macros • Extraction fan, 2-stage (external control or via switch clock)
can also be customized as needed. • Exhaust air temperature control with heating valve / heat recovery /
cooling valve (external potentiometer for desired value)
This DEOS library is used in conjunction with the • Filter monitoring for two filters (optional)
DEOS programming tool FUP XL. Programming • Refrigerating machine with 2 compressors and one evaporator
is thus standardized and fast. As a result, you (temperature demand via outside air temperature and switch clock)
save a great deal of programming time, reduce
sources of errors and simultaneously increase the Excerpt for application with various equipment Building Management
commissioning quality. Programming Tools
• Calculating of 24 hour mean value of outside air temperature
• Assessing of highest desired value from up to 8 desired values
(e.g. for boiler)
• time control with effective time extension

Article Type Art.-No.


MacLib DS-MacLib DS-371135
HVAC Macro library for the engineering tool FUP XL

Note: A training seminar is prerequisite for the purchase of the Macro Library (refer to category Training).

C 2018 - Technical changes excepted. Pictured products similar. 135


Notice

136 C 2018 - Technical changes excepted. Pictures similar.


Zone Control VAV / FCU
Zone Control VAV / FCU - Variable Air Volume / Fan Coil Unit Seite
VAV Controllers 138
FCU Controllers 139
Control units 140
Zone actuators 142
VAV / FCU

C 2018 - Technical changes excepted. Pictured products similar. 137


VAV - Variable Air Volume VAV / FCU

VAV controllers

Type DS-VAV T0 DS-VAV T2 DS-VAV T4 DS-VAV T4X DS-VPT 24


Actuators Art.-No. DS-600031 DS-600032 DS-600033 DS-600034 DS-600035

Communication BACnet MS/TP BACnet MS/TP BACnet MS/TP BACnet MS/TP BACnet MS/TP
Differential pressure sensor x x x x -
Wall mounting - - - - x
DIN Rail - - - x -
Power max. 10 VA 10 VA 10 VA 10 VA 1 VA

Actuator x x x - -
• Torque 8 Nm 8 Nm 8 Nm
• Run time 90 s 90 s 90 s

Digital inputs DI 2 2 2 2 -
Triac outputs TO 0 2 4 4 4
Universal inputs UI 2 2 2 2 3
Analog outputs AO 2 2 2 2 2

VAV control units

Type Art.-No.
DS-VAV CT24 DS-600051 3-wire 3-wire 3-wire 3-wire -
connection connection connection connection

DS-VAV CT33 DS-600052 3-wire 3-wire 3-wire 3-wire -


connection connection connection connection

Accessories
Type Art.-No.
Room tempera- DS-WTS 10K DS-600038 X X X X x
ture sensor 10K3

138 C 2018 - Technical changes excepted. Pictures similar.


VAV / FCU FCU - Fan Coil Unit

FCU Controllers

Type DS-FCU T0 V24 DS-FCU T2 V24 DS-FCU T4 V24 DS-FPT 24 DS-UPT


Power supply 24 V AC Art.-No. DS-600040 DS-600041 DS-600042 DS-600043 DS-600044

Type FCU T0 V240 FCU T2 V240 FCU T4 V240


Power supply 240 V AC Art.-No. DS-600048 DS-600049 DS-600050

Communication BACnet MS/TP BACnet MS/TP BACnet MS/TP BACnet MS/TP BACnet MS/TP
Power max. 8 VA 8 VA 8 VA 1 VA 1 VA
Wall mounting x x x x x
DIN Rail x x x - -
Digital inputs DI 4 4 4 1 2
Triac outputs TO 4 4 4 3 -
Analog inputs AI 6 6 6 2 2
Analog outputs AO 4 4 4 3 2
Digital outputs 3x5A 3x5A
3x5A
(fan) (fan) 3x1A 6x1A
(fan)
+2x3A +4x3A

Control units FCU

Type Art.-No.
DS-FCU CT24 DS-600036 3-wire 3-wire 3-wire - -
connection connection connection

DS-FCU CT33 DS-600037 3-wire 3-wire 3-wire - -


connection connection connection

Accessories
Type Art.-No.
Room temperature DS-WTS 10K DS-600038 x x x x x
sensor 10K3
VAV / FCU

C 2018 - Technical changes excepted. Pictured products similar. 139


NEU
Control Units VAV / FCU
NEW

Fan Coil Unit Thermostat

Description Technische Informationen


The Fan Coil Unit Thermostat “FCT Series” was developed • Power Supply 110 – 240 V, 50 -60 Hz
and designed to meet highest control demand for general • Dimensions refer to drawings
Fan Coil Unit applications in commercial, industrial and resi- • Power consumption < 1.5 W
• Interface Modbus RTU; selectable baudrate
dential buildings. It communicates via Modbus with a single
4.800 to 115.200 bps
room unit or network controller (such as DEOS SRU or • Sensor type NTC 10K ± 1°C
OPEN 810), but can also be used for stand-alone controls. • Temperature range 5 – 35 °C
In combination with a single room unit or network controller • Relay outputs Relay fan: 3x 5A;
from DEOS, various energy saving modes can be program- Relay valve: 2x 3A
med in order to increase your total energy efficiency. • Safety class IP20
The device combines digital technology with a large LCD • Body material PC, fireproof
touch screen, which enables the single room controller to • Working temperature 0 – 45°C;
• Working humidity 5 – 95% rH
be used intuitively. It is tailored for two-pipe and four-pipe
fan coil units with a three speed fan and either digital valve
control or analogue valve control. Necessary relays for fan
and valve control are already implemented as well as a
temperature sensor.

Article Type Art.-No.


FCT, black¹ DS-FCT B 2/4P On/Off DS-600053
Valve control with relays (open/close)
FCT, white¹ DS-FCT W 2/4P On/Off DS-600054
Valve control with relays (open/close)
FCT, black¹ DS-FCT B 2/4P 0-10V DS-600055
Valve control with constant 0-10V signal
FCT, white¹ DS-FCT W 2/4P 0-10V DS-600056
Valve control with constant 0-10V signal

1
delivery available from end of march 2018

140 C 2018 - Technical changes excepted. Pictures similar.


VAV / FCU Control Units

Control units
Type DS-LCF Touch DS-JOY-W DS-JOY-S
Power supply 230 V AC Art.-No. DS-1650130 DS-1650144 DS-1650172

Communication MODBUS RTU MODBUS RTU MODBUS RTU


Housing color black white black
Power max.
Digital inputs DI - 1 1
Digital outputs DO - - -
Analog inputs AI - - -
Analog outputs AO - - -
5x3A 5x3A 5x3A

VAV / FCU

C 2018 - Technical changes excepted. Pictured products similar. 141


VAV / FCU Zone Valves
3-point constant
AC 230 V AC/DC 24 V

Zone actuators
Type CQ230A CQ24A CQ24A-SR CQK24A-SR
Zone actuators Art.-No. DS-475055 DS-475052 DS-475053 DS-475054

Torque 1 Nm 1 Nm 1 Nm 1 Nm
Run time 75 s 75 s 75 s 75 s
Emergency function - - - x
Run time emergency function - - - -
Control - - DC 0 .. 10 V DC 0 .. 10 V
Working range / feedback - - - -

2-way control ball valve, female thread, PN 16, +2 ... +90 °C

DN kvs [m³/h] Type Art.-No. possible combination


15 0.4 - 4.8 C215Q-J DS-494119 x x x x
20 0.5 - 8 C220Q-K DS-494120 x x x x

3-way control ball valve, female thread, PN 16, +2 ... +90 °C

DN kvs [m³/h] Type Art.-No. possible combination


15 2.5 C315Q-H DS-494121 x x x -
20 4.0 C320Q-J DS-494122 x x x -

Tube fittings

DN Zoll Type Art.-No.


15 1/2“ ZR2315 DS-491430
20 3/4“ ZR2320 DS-491431

142 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors
Sensors Page
Temperature sensors 144
Room temperature sensors - Room control units 149
Humidity sensors 156
Brightness sensors - Air quality sensors 160
Pressure switches - Pressure transducers 166
Condensation sensor 172

Average temperature sensor 173


Frost protection thermostat 174
Wireless sensors 175
Immersion sleeves 180
Accessories 181
Measurement chart 182
Duct Smoke Sensor 184

C 2018 - Technical changes excepted. Pictured products similar. 143


TTF/KTFxxx Sensors

Immersion-/Duct sensor for measurement of air temperature and other gaseous mediums for HVAC
applications (e.g. supply and exhaust ducts).Can be used as an immersion temperature sensor combined
with a thermowell pocket. Delivery does not include thermowell pockets.
TTF/KTFxxx
Enclosure enclosure USE-S 63x51x40 mm, PA6, pure white
Protection IP65
Cable entry M16 for cable max. Ø=8 mm, removeable
Measuring range LM: -35°C .. +120°C, Pt1000: -35°C .. +120°C
Max. head temp +90°C
Sensor pocket stainless steel V4A, Ø=6 mm
Connection removeable plug-in terminal, max. 2,5 mm²
Accessories Mounting clip included

Measuring element LM 10 mV / K Type Art.-No.


Mounting lenght (L) 50 mm DS-TTF/KTF050.LM.USE DS-1650155
Mounting lenght (L) 100 mm DS-TTF/KTF100.LM.USE DS-1650156
Mounting lenght (L) 150 mm DS-TTF/KTF150.LM.USE DS-1650157
Mounting lenght (L) 200 mm DS-TTF/KTF200.LM.USE DS-1650158
Mounting lenght (L) 250 mm DS-TTF/KTF250.LM.USE DS-1650159
Mounting lenght (L) 300 mm DS-TTF/KTF300.LM.USE DS-1650160
Mounting lenght (L) 450 mm DS-TTF/KTF450.LM.USE DS-1650161

Measuring element Pt1000 Type Art.-No.


Mounting lenght (L) 50 mm DS-TTF/KTF050.Pt1000.USE DS-1670032
Mounting lenght (L) 100 mm DS-TTF/KTF100.Pt1000.USE DS-1670033
Mounting lenght (L) 150 mm DS-TTF/KTF150.Pt1000.USE DS-1670034
Mounting lenght (L) 200 mm DS-TTF/KTF200.Pt1000.USE DS-1670035
Mounting lenght (L) 250 mm DS-TTF/KTF250.Pt1000.USE DS-1670036
Mounting lenght (L) 300 mm DS-TTF/KTF300.Pt1000.USE DS-1670037
Mounting lenght (L) 450 mm DS-TTF/KTF450.Pt1000.USE DS-1670038

Dimensions Connection

Note:
Delivery does not
include thermowell
pockets. Please see Note:
page 179 for suitable When connecting the LM sensors you have to
immersion pockets. observe the polarity.

144 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors TTF/KTFxxx

TTF/KTF.xxx.MR
Enclosure enclosure USE-S 63x51x40 mm, PA6, pure white
Protection IP65
Cable entry for cable max. Ø=8 mm, removeable
Measuring range selectable on device: -50..+50 | -20..+80 | -15..+35
| -10..+120 | 0..+50 | 0..+100 | 0..+160 | 0..+250 °C,
standard setting: 0..+160 °C
Max. head temp +90°C
Sensor pocket stainless steel V4A, Ø=6 mm
Connection removeable plug-in terminal, max. 2,5 mm²
Accessories Mounting clip included

Measuring element 0 .. 10 V active Type Art.-No.


Mounting lenght (L) 50 mm DS-TTF/KTF050.MR.USE DS-1650165
Mounting lenght (L) 100 mm DS-TTF/KTF100.MR.USE DS-1650166
Mounting lenght (L) 150 mm DS-TTF/KTF150.MR.USE DS-1650167
Mounting lenght (L) 200 mm DS-TTF/KTF200.MR.USE DS-1650168
Mounting lenght (L) 250 mm DS-TTF/KTF250.MR.USE DS-1650169
Mounting lenght (L) 300 mm DS-TTF/KTF300.MR.USE DS-1650170
Mounting lenght (L) 450 mm DS-TTF/KTF450.MR.USE DS-1650171

Note:
For replacement or repair purposes in existing systems you may continue to order the previous
DS-TTFxxx and DS-KTFxxx sensors with Ø 7 mm on request. These sensors are no stock goods, so
that delivery times may be longer.

Connection
Dimensions

Note:
Delivery does not
include thermowell
pockets. Please see
page 179 for suitable
immersion pockets.
C 2018 - Technical changes excepted. Pictured products similar. 145
ATF.xx Sensors

Outside air temperature sensor suitable for open-air installation.

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-ATF.LM.USE DS-1650153
Housing enclosure USE-S 63x51x40 mm,
PA6, pure white
Protection IP65
Measuring range -35°C...+90°C
Cable entry M16, max. cable dia. 8 mm
Connection removeable plug-in terminal,
max. 2,5 mm²

Accessories Sun / rain protection DS-ATF/protection DS-1650001


stainless steel 1.4301

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-ATF.Pt1000.USE DS-1650154
Housing enclosure USE-S 63x51x40 mm,
PA6, pure white
Protection IP65
Measuring range -35°C...+90°C
Cable entry M16, max. cable dia. 8 mm
Connection removeable plug-in terminal,
max. 2,5 mm²

Accessories Sun / rain protection DS-ATF/protection DS-1650001


stainless steel 1.4301

Dimensions Connection

Note:
When connecting the LM sensors you have to
observe the polarity.

146 C 2018 - Technical changes excepted. Pictures similar.


Sensors
NEU
Sensors ALTF.xx
NEW

Sensor with hinged lid enclosure USE for temperature measurement of pipes and round surfaces. Spring
loaded brass contact sensor. Delivery does not include tightening strap.

ALTF.xx
Housing enclosure USE-S, PA6, pure white
Protection IP65
Cable entry M16, max. cable dia. 8 mm
Connection removeable plug-in terminal, max. 2,5 mm²
Hülse Messing, gefederter Sensorkontakt
Note for mounting Mounting with tightening strap, for better heat transfer
use heat conducting paste
Remarks Suitable for all pipe gauges up to 2 “, optimum surface
contact with sensor pressure spring
Related accessories Mounting clip included
Note Supplied without tightening strap

measuring element passive measuring range Type Art.-No.


LM 10 mV/K -35°C .. +90°C DS-ALTF.LM.USE DS-1650179
Pt1000 -35°C .. +90°C DS-ALTF.Pt1000.USE DS-1650178
measuring element active measuring range Type Art.-No.
0 .. 10 V adjustable at the transducer: DS-ALTF.MR.USE DS-1650177
-50..+50 | -20..+80 | -15..+35
-10..+120 | 0..+50 | 0..+100
0..+160 | 0..+250 °C, default
settings: 0..+100 °C

Accessories Type Art.-No.:


Clamp for Ø up to 110 mm with thermal contact fluid DS-SPS110 DS-1650565
Clamp for Ø up to 250 mm with thermal contact fluid DS-SPS250 DS-1650566
PA Tightening strap for Ø up to 100 mm with thermal DS-SPB100 DS-1650567
contact fluid

Connection
passive active
Dimensions

Note:
When connecting the LM sensors you have to observe the polarity.

C 2018 - Technical changes excepted. Pictured products similar. 147


KLTF Sensors

Cable temperature sensor for measuring of gaseous media, - or for liquid media when
using an immersion sleeve.

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-KLTF.LM DS-1650200
Probe sleeve 6.5 mm dia. stainless steel 1.4571
Install length L = 50 mm
Ambient air temp. -35°C ..+100°C
Protection IP54
Connecting cable PVC/HT, 2 x 0,25 mm², length 2 m,
firmly connected cable

Measuring element Pt1000 Type Art.-No.


Active meas. probe PT 1000 DS-KLTF.Pt1000 DS-1670002
Probe sleeve 6.5 mm dia. stainless steel 1.4571
Install length L = 50 mm
Ambient air temp. -35°C .. +100°C,
Protection IP54
Connecting cable PVC/HT, 2 x 0,25 mm², length 2 m,
firmly connected cable

Dimensions Connection Connection


LM Pt1000

A- = white
B+ = brown

148 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors RTF1.A

Room temperature sensor for assessing temperatures inside of private homes, offices, etc. for wall
mounting in attractive DEOS design housing

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-RTF1.A.LM DS-520001
Housing ABS, color RAL9010
Protection IP20
Measuring range -35°C...+70°C
Connection 2-pole terminal

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-RTF1.A.Pt1000 DS-520008
Housing ABS, color RAL9010
Protection IP20
Measuring range -35°C...+70°C
Connection 2-pole terminal

Dimensions Dimensions base plate


Connection Connection
LM Pt1000

C 2018 - Technical changes excepted. Pictured products similar. 149


RTF.I Sensors

Room temperature sensor, industrial design, for assessing of temperature in storage halls, rooms,
offices, etc.. The sensor is cast in an external probe sleeve.

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-RTF.I.LM.USE DS-1670039
Housing enclosure USE-S 63x51x40 mm,
PA6, pure white
Protection IP65
Measuring range -35°C...+90°C
Probe sleeve Stainless steel V4A
Cable entry M16, max. cable dia. 8 mm
Connection removeable plug-in terminal,
max. 2,5 mm²

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-RTF.I.Pt1000.USE DS-1670040
Housing enclosure USE-S 63x51x40 mm,
PA6, pure white
Protection IP65
Measuring range -35°C...+90°C
Probe sleeve Stainless steel V4A
Cable entry M16, max. cable dia. 8 mm
Connection removeable plug-in terminal,
max. 2,5 mm²

Dimensions

Note:
When connecting the LM sensors you have to
observe the polarity.

150 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors RFPTD1.A

Remote control unit with room temp. sensor, button for presence detection, LED, potentiometer for set
point adjustment, wall mounting in attractive DEOS design housing

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-RFPTD1.A.LM DS-520002
Housing ASA (ABS), color RAL9010
Protection IP30
Ambient temp. -35°C...+70°C
Connection Screw terminals
Note P = Potentiometer,
10000 Ohm 0.1 W
T = Button, breaking capacity 600 mW
D = LED, green, 24 V DC

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-RFPTD1.A.Pt1000 DS-520009
Housing ASA (ABS), color RAL9010
Protection IP30
Ambient temp. -35°C...+70°C
Connection Screw terminals
Note P = Potentiometer,
10000 Ohm 0.1 W
T = Button, breaking capacity 600 mW
D = LED, green, 24 V DC

Dimensions Dimensions Connection LM


base plate

Connection Pt1000

C 2018 - Technical changes excepted. Pictured products similar. 151


RF2P2STD Sensors

Remote control unit with room temperature sensor, button for presence detection, LED,
potentiometer for set point adjustment and 2-stage fan potentiometer,
wall mounting in surface-mount housing

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-RF2P2STD.LM DS-1650563
Housing ASA (ABS),
color pure white similar RAL9010,
Protection IP30
Ambient temp. -35°C .. +70°C
Connection Screw clamps
control elements P1 = setpoint potentiometer
P2 = fan control
2-stage, w/o detent position
T = Button, breaking capacity 600 mW
D = LED, green, 24 V DC

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-RF2P2STD.Pt1000 DS-1670019
Housing ASA (ABS),
color pure white similar RAL9010,
Protection IP30
Ambient temp. -35°C .. +70°C
Connection Screw clamps
control elements P1 = setpoint potentiometer
P2 = fan control
2-stage, w/o detent position
T = Button, breaking capacity 600 mW
D = LED, green, 24 V DC

Dimensions Connection LM

Connection Pt1000

152 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors RF2P3STD

Remote control unit with room temperature sensor, button for presence detection, LED,
potentiometer for set point adjustment and 3-stage fan potentiometer,
wall mounting in surface-mount housing

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-RF2P3STD.LM DS-1650564
Housing ASA (ABS),
color pure white similar RAL9010,
Protection IP30
Ambient temp. -35°C .. +70°C
Connection Screw clamps
control elements P1 = setpoint potentiometer
P2 = fan control
3-stage, w/o detent position
T = Button, breaking capacity 600 mW
D = LED, green, 24 V DC

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-RF2P3STD.Pt1000 DS-1670020
Housing ASA (ABS),
color pure white similar RAL9010,
Protection IP30
Ambient temp. -35°C .. +70°C
Connection Screw clamps
control elements P1 = setpoint potentiometer
P2 = fan control
3-stage, w/o detent position
T = Button, breaking capacity 600 mW
D = LED, green, 24 V DC

Dimensions Connection LM

Connection Pt1000

C 2018 - Technical changes excepted. Pictured products similar. 153


RFTD.A Sensors

Remote control unit with room temperature sensor, button for presence detection, LED and
wall mounting in surface-mount housing

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-RFTD.A.LM DS-1650650
Housing ASA (ABS),
white, similar RAL9010
Protection IP30
Ambient temp. -35°C...+70°C
Connection screw terminals

Note T = Button, breaking capacity 600 mW


D = LED, green, 24 V DC

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-RFTD.A.Pt1000 DS-1670016
Housing ASA (ABS),
white, similar RAL9010
Protection IP30
Ambient temp. -35°C...+70°C
Connection screw terminals

Note T = Button, breaking capacity 600 mW


D = LED, green, 24 V DC

Dimensions Connection LM

Connection Pt1000

154 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors RFP.A

Remote control unit with room temperature sensor and potentiometer for set point adjustment,
wall mounting in surface-mount housing

Measuring element LM Type Art.-No.


Active meas. probe 10 mV / K DS-RFP.A.LM DS-1650651
Housing ASA (ABS),
white, similar RAL9010
Protection IP20
Ambient temp. -35°C...+70°C
Connection screw terminals

Note P = Potentiometer,
5 kOhm 0.25 W

Measuring element Pt1000 Type Art.-No.


Active meas. probe Pt1000 DS-RFP.A.Pt1000 DS-1670017
Housing ASA (ABS),
white, similar RAL9010
Protection IP30
Ambient temp. -35°C...+70°C
Connection screw terminals

Note P = Potentiometer,
5 kOhm 0.25 W

Dimensions Connection LM

Connection Pt1000

C 2018 - Technical changes excepted. Pictured products similar. 155


RFF.A Sensors

Article Type Art.-No.


Room air humidity sensor DS-RFF.A DS-1650351
for assessing of relative air humidity in homes, offices, etc.

Housing ASA (ABS),


white, similar RAL9010
Protection IP30
Ambient air temp. -20°C .. +70°C
Output rh 0 .. 10 V DC
Measuring range rh 0% .. 100%rh = 0 - 10V DC
Tolerance +/- 2% (10% .. 90%rh)
Output temp. 0 .. 10 V DC
Measuring range temp. 0 .. 50°C = 0 - 10V DC
Supply voltage 15 - 24V= / 24V~ +-10%
Connection Screw terminals

Dimensions Measuring chart Measuring chart


temperature* humidity

0 .. 10 V 0 .. 10 V
[t]°C [Volt]V %rF [Volt]V
-20 - 0 0.0
-10 - 10 1.0
0 0.0 20 2.0
10 2.0 30 3.0
20 4.0 40 4.0
30 6.0 50 5.0
40 8.0 60 6.0
50 10.0 70 7.0
60 - 80 8.0
70 - 90 9.0
80 - 100 10.0

*The voltage values have to be measured in a connected state under


operating conditions with a multimeter.

Connection

156 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors RFF/TF.A

Article Type Art.-No.


Humidity sensor DS-RFF/TF.A.LM DS-1650501
with integrated room temperature sensor
for assessing of temperature and relative air humidity in
homes, offices, etc.

Active measuring probe 10 mV / K


Measuring range 0 .. 50°C
Housing ASA (ABS),
white, similar RAL9010
Protection IP30
Ambient air temp. -20°C .. +70°C
Outpur rh 0 .. 10 V DC
Measuring range rh 0% .. 100%rh = 0 - 10V DC
Tolerance +/- 2% (10% .. 90%rh)
Output temp. 0 .. 10 V DC
Meas. range temp. 0 .. 50°C = 0 - 10V DC
Supply voltage 15 - 24V= / 24V~ +- 10%
Connection Screw terminals

Dimensions Measuring chart Measuring chart


temperature* humidity

LM 0 .. 10 V 0 .. 10 V
[t]°C [Volt]V [Volt]V %rh [Volt]V
-20 2.532 - 0 0.0
-10 2.632 - 10 1.0
0 2.732 0.0 20 2.0
10 2.832 2.0 30 3.0
20 2.932 4.0 40 4.0
30 3.032 6.0 50 5.0
40 3.132 8.0 60 6.0
50 3.232 10.0 70 7.0
60 3.332 - 80 8.0
70 3.432 - 90 9.0
80 3.532 - 100 10.0

*The voltage values have to be measured in a connected state under


operating conditions with a multimeter.

Connection
24V AC/DC

C 2018 - Technical changes excepted. Pictured products similar. 157


NEU
KFF/TF Sensors
NEW


KFF Duct humidity and temperature sensor in new hinged lid
enclosure USE for all HVAC duct applications.
Enclosure enclosure USE-S, PC, pure white
Protection IP65 at mounting head
Cable entry M16, max. cable Ø 8 mm

Pipe PA6, black, Ø=19,5 mm, length=140 | 270 | 400 mm


inkl.
Ambient condition -20..+70 °C, short term condensation

Power supply 15..24 V = (±10%) or 24 V ~ (±10%) SELV

Power consumption typ. 0,4 W (24 V =) | 0,8 VA (24 V ~)

Connection electrical removable plug-in terminal, max. 2,5 mm²

Delivery incl. mounting flange

Output voltage rH 0..10 V or 0..5 V, configurable via Jumper, min. load 10 kΩ

Measuring range rH 0% .. 100% rH = 0 - 10 V DC

Accuracy humidity ±2% between 10..90% rH (typ. at 21 °C)


Meas. range abs. hum. adjustable 0..50 | 0..80 g/m³, default setting: 0..50 g/m³
Meas. range enthalpy 0..85 KJ/kg
Meas. range dew point adjustable 0..50 | -20..+80 °C, default: 0..50 °C
Output Temp. 0..10 V or 0..5 V, configurable via Jumper, min. load 10 kΩ
Meas. range Temp. adjustable at the transducer: -20..+80 | 0..+50 | -40..+60 |
-15..+35 °C; default setting: -20..+80 °C


Measuring range Type Art.-No.
Humidity 0..10V DS-KFF.USE DS-1650190
Temperature 0..10V
additional measuring element passive
LM 10 mV/K Temeprature -35°C .. +90°C DS-KFF.LM.USE DS-1650191
Pt1000 Temeprature -35°C .. +90°C DS-KFF.Pt1000.USE DS-1650192

Dimensions Connection
UB+ Supply 24V AC/DC
GND Ground
AOU1 Humidity Output 0 .. 10V
AOU2 Temperature Output 0 .. 10V
ST+ Sensor LM +
ST- Sensor LM -

Note:
When connecting the LM sensors you have to observe the polarity.

158 C 2018 - Technical changes excepted. Pictures similar.


Sensors
NEU
Sensors AFF/TF
NEW

AFF Sensor for measuring humidity and temperature in outdoor


areas. In delivery condition, the sensor is designed for
measuring temperature and relative humidity.
Enclosure enclosure USE-M, PC, pure white
Protection IP65 according to EN 60529
Cable entry M16, max cable Ø 8 mm, removable

Filter stainless steel wire mesh

Ambient condition -20..+70 °C, short term condensation

Power supply 15..24 V = (±10%) or 24 V ~ (±10%) SELV

Power consumption typ. 0,4 W (24 V =) | 0,8 VA (24 V ~)

Connection removable plug-in terminal, max. 2,5 mm²

Delivery incl. mounting base and rain protection

Output rF 0..10 V or 0..5 V, configurable via Jumper, min. load 10 kΩ

Measuring range rF 0% .. 100% rF = 0 - 10 V DC

Accuracy Humidity +/- 2% (10% .. 90% rF)


Meas. range Humidity adjustable 0 .. 50 g/m³ / 0 .. 80 g/m², default: 0 .. 50 g/m³
Meas. range Enthalpi 0 .. 85 KJ/kg
Meas. dew point adjustable 0 .. 50 °C / -20 .. 80 °C, default: 0 .. 50 °C
Output Temp. 0..10 V / 0..5 V, configurable via Jumper, min. load 10 kΩ
Meas. range Temp. adjustable at the transducer: -20..+80 | 0..+50 | -40..+60 |
-15..+35 °C; default setting: -20..+80 °C

Measuring range Type Art.-No.


Humidity 0..10V DS-AFF.USE DS-1650405
Temperature 0..10V
additional measuring element passive
LM 10 mV/K Temeprature -35°C .. +90°C DS-AFF.LM.USE DS-1650403
Pt1000 Temeprature -35°C .. +90°C DS-AFF.Pt1000.USE DS-1650404

C 2018 - Technical changes excepted. Pictured products similar. 159


HF0-20 Sensors

Article Type Art.-No.


Brightness sensor DS-HF0-20 DS-1650045
for monitoring of illumination intensity.
Application: Monitoring of lighting, shutters, blinds etc.
Use outside, industrial halls, etc.

Housing Polyamide, white


Protection IP65
Cable entry M20
Ambient air temp. -30°C .. +70°C
Sensor BPW21
Measuring ranges LRV1: 0 .. 2 kLux
(Selected at unit) LRV2: 0 .. 20 kLux
LRV3: 0 .. 100 kLux
Supply voltage 15 - 24 V= / 24 V~
Output 0 .. 10 V,
Load min. 5 kOhm,
3-lead connector
Current consumption approx. 20 mA / 24 V=
Connection multi-pole screw connector

Dimensions Connection

1 3 3

3 3
1

Information:
The sensor BPW21 utilizes an integrated
color filter matching the human eye. The
output signal 0 ...10 V= is linear for the whole
measuring range. The measuring accuracy
depends on the light’s angle of incidence -- Setting of measuring range:
Max. accuracy when perpendicular (0°).
10 % reduction for every added 10°. measuring DIP-switches DIP-switches DIP-switches
2kLux SW1: ON SW2: OFF SW3:OFF
20kLux SW1: OFF SW2: ON SW3:OFF
100kLux SW1: OFF SW2: OFF SW3:ON
*other measuring ranges on request

160 C 2018 - Technical changes excepted. Pictures similar.


Sensors
NEU
Sensors LK+ VOC
NEW


LK+ VOC V Duct air quality sensor for detection of VOC air quality, and
optional humidity combined in one unit. Designed for duct
mounted applications with up to 3 0..10 V outputs.
Enclosure enclosure USE-M, PC, pure white, with removable cable
entry
Protection IP65 according to EN 60529
Cable entry V M16, for wire max. Ø=8 mm

Ambient condition 0..+50 °C, max. 85% rH short term condensation incl.
Pipe V PA6, black, Ø=19,5 mm, length 150 mm

Power supply 15..35 V = or 19..29 V ~

Power consumption max. 2,3 W (24 V =) | max. 4,3 VA (24 V ~)

Connection electrical removeable plug-in terminal, max. 2,5 mm²

Output voltage V 0..5 V, min. load 10 kΩ

Air speed min. 0,3 m/s, max. 12 m/s

Calibration self-calibration

Sensor VOC sensor (heated metal oxide semiconductor)

Delivery incl. mounting flange


Measuring values Type Art.-No. PG €
VOC (mixed gas) DS-LK+ VOC V DS-1650538 D1

Dimensions Connection DS-LK+ VOC

DS-LK+ VOC
n.c. free terminals
n.c not used
n.c not used
AOU1 VOC 0..10V
GND Ground
UB+ 15..35 V = or 19..29 V

Caution!! Free terminals must not be used as connecting terminals

C 2018 - Technical changes excepted. Pictured products similar. 161


RLQF Sensors

Article Type Art.-No.


Room air quality sensor DS-RLQF DS-1650602
for monitoring of mixed gas concentrations in gaseous
media.

Measuring probe Tin dioxide semiconductor


Output 0 .. 10 V DC
Connector head Polyamide, white
Protection IP20
Cable entry M20
Probe tip max. +50°C
Head temp. max. +50°C
Supply voltage 15 - 24V= / 24V~
Current consumption 1,2 W (24 V DC), 2,2 VA (24 V AC)
Connection 3-pole screw connector

Dimensions Connection Information

The sensor can not determine between pleasant and unple-


asant odours. This is to be determined by the persons in the
room who eventually decide on the room air quality. Further
to this, rooms may feature different ingredients.

This explains why the factory setting for the desired air quality
is an estimate only. The setting must be optimized during
installation and commissioning of the system.

Individual adaptation of the output signal is effected via the


trimming potentiometer on the board. It is used to increase or
decrease the offset of the output signal.

Procedure for installation / commissioning:

1. Connect sensor and switch on supply voltage.


2. Check for good air quality in duct.
3. After approx. 30 min. turn potentiometer left until red
LED starts to go off.
Now, the output signal is approx. 0.7 V.
4. The sensor is ready for use -
The voltage for the output signal increases with decrea-
sing air quality.

Note:
• Output voltage increases with decreasing air quality.
• Offsetting of output signal variable via
trimming potentiometer.
• Operating status via LED.

162 C 2018 - Technical changes excepted. Pictures similar.


Sensoren
Sensors
NEU
Sensors WRF04 C02
NEW

WRF04 CO2 Surface mounted sensor for detection of CO2, temperature


and optional relative humidity in room and office spaces.
Enclosure PC, pure white
Protection IP30 according to EN 60529
Cable entry breaking points top/bottom, entry on rear

Ambient condition 0..+50 °C, max. 85% rH non-condensing

Power supply 15..24 V = (±10%) or 24 V ~ (±10%)

Power consumption max. 3 W (24 V = | 6 VA (24 V =)

Conenction electrical terminal block, max. 1,5mm²

Output CO2 0..10 V, min. load 10 kΩ

Measuring range CO2 0..2000 ppm

Accuracy CO2 ±75 ppm or 10% of measuring range (typ. at 21 °C), wha- with TLF
tever is greater
Calibration CO2 self-calibration, dual channel

Sensor CO2 NDIR (non-dispersive, infrared)

TLF CO2 3 LEDs showing air quality (traffic light function ‘TLF’) (optional)

Output Temp. 0..10 V, min. load 10 kΩ

Meas. range Temp 0..+50 °C

Output Humidity 0..10 V, min. load 10 kΩ

Meas. range Humidity 0% .. 100% rH non-condensing

Accuracy Humidity ±2% between 10..90% rH (typ. at 21 °C)

Messurand Type Art.-No.


CO2 and Temperature DS-WRF04 CO2 VV DS-1650518
CO2 with displaying level of CO2 and Temperature DS-WRF04 CO2 VV TLF DS-1650534
CO2, Temperature and Humidity DS-WRF04 CO2 rH 3xV DS-1650519

Dimensions Connection

DS-WRF04 CO2 VV xxx


Terminal 1 = GND / AC2
Terminal 2 = UB +24 V ~/AC1
Terminal 3 = Temp. 0 .. 10 V
Terminal 4 = CO2 0 .. 10 V
Terminal 5 to 10 = free
DS-WRF04 CO2 rH 3xV
Terminal 1 = GND / AC2
Terminal 2 = UB +24 V ~/AC1
Terminal 3 = Temp. 0 .. 10 V
Terminal 4 = CO2 0 .. 10 V
Terminal 5 = rel. Humidity 0 .. 10 V
Terminal 6 to 10 = free
Caution!! Free terminals must not be used as connecting terminals
C 2018 - Technical changes excepted. Pictured products similar. 163
NEU
LK+ CO2 Sensors
NEW


LK+ CO2 Duct air quality sensor for detection of CO2, optional with
temperature and humidity.
Enclosure enclosure USE-M, PC, pure white, with removeable cable
entry
Protection IP65 according to EN 60529
Cable entry V M16, for wire max. Ø=8 mm

VV M16, for wire max. Ø=8 mm


incl.
3xV M20, for wire max. Ø=10 mm, seal insert for
double cable entry for wire max Ø=6 mm
Ambient condition 0..+50 °C, max. 85% rH short term condensation

Pipe V PA6, black, Ø=19,5 mm, length 150 mm

VV PA6, black, Ø=19,5 mm, length 180 mm

3xV PA6, black, Ø=19,5 mm, length 180 mm

Power supply 15..35 V = or 19..29 V ~

Power consumption max. 2,3 W (24 V =) | 4,3 VA (24 V ~)

Connection electrical removeable plug-in terminal, max. 2,5 mm²

Output CO2 V 0..10 V min. load 10 kΩ

VV 0..10 V or 0..5 V, min. load 10 kΩ

3xV 0..10 V or 0..5 V, min. load 10 kΩ

Measuring range CO2 0..2000 ppm

Accuracy CO2 ±50 ppm +3% of reading (typ. at 21 °C, 50% rH)

Air speed min. 0,3 m/s, max. 12 m/s

Calibration CO2 self-calibration, Dual Channel

Sensor CO2 NDIR (non-dispersiv, infrared)

Output Temp. 0..10 V or 0..5 V, min. load 10 kΩ

meas. range Temp 0..+50 °C (default setting)


optionally configured via USEapp
Accuracy Temp. ±0,5 K (typ. at 21 °C)

Output Humidity 0..10 V or 0..5 V, min. load 10 kΩ

meas. range Humidity 0% .. 100% rH non-condensing

Accuracy Humidity ±2% between 10..90% rH (typ. at 21 °C)


Measuring values Typ Art.-Nr.
CO2 DS-LK+ CO2 V DS-1650537
CO2 and Temperature DS-LK+ CO2 VV DS-1650535
CO2, Temperature and Humidity DS-LK+ CO2 3xV DS-1650536

164 C 2018 - Technical changes excepted. Pictures similar.


Sensors
NEU
Sensors LK+ C02
NEW

DS-LK+ V
n.c. free terminal
n.c free terminal
n.c free terminal
AOU1 CO2 0..10V
GND Ground
UB+ 15..35 V = or 19..29 V

DS-LK+ VV
n.c. free terminal
n.c free terminal
AOU2 Temperature 0..10V
AOU1 CO2 0..10V
GND Ground
UB+ 15..35 V = or 19..29 V

DS-LK+ 3xV
n.c. free terminal
n.c free terminal
AOU2 Temperature 0..10Vt
AOU1 CO2 0..10V
GND Ground
UB+ 15..35 V = or 19..29 V

nc. free terminal


AOU3 Humidity 0..10V

Caution!! Free terminals must not be used as connecting terminals

Dimensions

C 2018 - Technical changes excepted. Pictured products similar. 165


PSxxx Differential pressure switches


Article Type Art.-No.
Differential pressure switch
for monitoring of differential pressure at air filters or fans.
Delivery w/o mounting flange.

Medium Air or other non-aggressive gases


Switching power 2 A inductive load max. 250 V AC
3 A resistive load
Switching differential 20 Pa
max. operating pressure 50 kPa
Working temp. -20 .. +60°C
Cable entry PG 9
Pressure connection Dia. 5 mm
Protection IP 54

Accessories 2 plastic connecting piece


2 m plastic tube D= 4/7
2 mounting screws
Adjustable pressure range 30 .. 300 Pa DS-PS 300 DS-1650511
switching difference 20 Pa
Adjustable pressure range 30 .. 500 Pa DS-PS 500 DS-1650512
switching difference 20 Pa
Adjustable pressure range 100 .. 1500 Pa DS-PS 1500 DS-1650528
switching difference 80 Pa
Accessories optional mounting bracket DS-PS-MW DS-1650522
for DS-PS xxxx

Dimensions Mounting bracket (optional)

Measurements in mm

Connection

When the differential pressure is present:

1 - 3 open
1 - 2 closed

166 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Pressure measuring transducer DLMxx

Article Type Art.-No.


Press. meas. transducer
for fluid media in air-conditioning, heating and water
installations. Suitable for systems with refrigerants.

Press. meas. transducer


Supply voltage 15 - 24 V DC / 24 V AC (+/-10%)
select at device: typ. 0,15W / 0,3VA
Accuracy typ. 0,7%
in the temperature range 20 ..+ 85°C
Output 0 .. 10 V
Temp. of medium -40 .. +125°C
Ambient air temp. -40 .. +105°C
Overload range double nominal pressure
Overload protection G1/2”
Protection IP65

Press. meas. transducer DS-DLM4V G1/2” DS-1650067


Meas. range 0 .. 4 bar
Press. meas. transducer DS-DLM6V G1/2” DS-1650068
Meas. range 0 .. 6 bar
Press. meas. transducer DS-DLM10V G1/2” DS-1650069
Meas. range 0 .. 10 bar
Press. meas. transducer DS-DLM16V G1/2” DS-1650098
Meas. range 0 .. 16 bar
Press. meas. transducer DS-DLM25V G1/2” DS-1650099
Meas. range 0 .. 25 bar

Dimensions Connection

1 = 15..24 V = / 24 V ~
2 = GND
3 = Out 0..10 V

C 2018 - Technical changes excepted. Pictured products similar. 167


DPA+ xx Pressure measuring transduce
NEU
NEW
DPA+
Differential pressure and volume flow transducer for monitoring differential pressure and volume
flow of air and other non-flammable and non-aggressive gases.

Measuring values differential pressure, volume flow


Output voltage VV 0..10 V or 0..5 V min. load 10 kΩ
Output Amp AA 4..20 mA, max. load 500 Ω

Output switch contact Relay 2 floating contacts for 24 V ~ or 24 V = / 3 A

Power supply VV 15..35 V = or 19..29 V ~

AA 15..35 V =

Relay 15..35 V = or 19..29 V ~

Power consumption max. 2,3 W (24 V =) | 4,3 VA (24 V ~)

Meas. range Pressure am Gerät einstellbar

Type 250 0..+25 | 0..+50 | 0..+100 | 0..+250 | -25..+25 | -50..+50 | -100..+100 | -150..+150 Pa

Type 2500 -100..+100 | 0..+100 | 0..+250 | 0..+500 | 0..+1000 | 0..+1500 | 0..+2000 | 0..+2500 Pa

Type 7500 0..+1000 | 0..+1500 | 0..+2000 | 0..+2500 | 0..+3000 | 0..+4000 | 0..+5000 | 0..+7000 Pa

Accuracy Pressure deviation from calibration reference device (calibrator)

Type 250 ±1 Pa at range <250 Pa

Type 2500 ±5 Pa at range <500 Pa, ±10 Pa at range >500 Pa

Type 7500 ±10 Pa at range <2000 Pa, ±25 Pa at range >2000 Pa

Max. working over- 40 kPa


pressure
Calibration manually
automatic zero-point calibration (optional)
Semsor piezo measuring element

Enclosure enclosure USE-L, PC, pure white, with removeable cable entry

Protection IP65 according to DIN EN 60529

Cable entry VV M16, for wire max. Ø=8 mm

AA M16, for wire max. Ø=8 mm

Relay M20, for wire max. Ø=10 mm


seal insert for double cable entry for wire max Ø=6 mm
Connection electrical removeable plug-in terminal, max. 2,5 mm²
Connection mech. pressure connection male Ø=5,0 mm / Ø=6,3 mm, connection tube: PVC, soft
Ambient condition -10..+50 °C, max. 85% rH short term condensation
Mounting screw mounted onto flat surface, prepared for mounting on DIN rail TS35 (35x7,5 mm) according to
EN 60715

168 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Pressure measuring transduce DPA+ xx
NEU
NEW
Without LCD Type Art.-No.
Type 250
DS-DPA250+ VV DS-1650727
DS-DPA250+ VV AZ DS-1650728
DS-DPA250+ AA DS-1650731
DS-DPA250+ AA AZ DS-1650732
DS-DPA250+ VV+R DS-1650735
DS-DPA250+ VV+R AZ DS-1650736
Type 2500
DS-DPA2500+ VV DS-1650739
DS-DPA2500+ VV AZ DS-1650740
DS-DPA2500+ AA DS-1650743
DS-DPA2500+ AA AZ DS-1650744
DS-DPA2500+ VV+R DS-1650747
DS-DPA2500+ VV+R AZ DS-1650748
Type 7500
DS-DPA7500+ VV DS-1650751
DS-DPA7500+ VV AZ DS-1650752
DS-DPA7500+ AA DS-1650755
DS-DPA7500+ AA AZ DS-1650756
DS-DPA7500+ VV+R DS-1650759
DS-DPA7500+ VV+R AZ DS-1650760

Dimensions

C 2018 - Technical changes excepted. Pictured products similar. 169


DPA+ xx Pressure measuring transduce
NEU
NEW
DPA+
Differential pressure and volume flow transducer for monitoring differential pressure and volume
flow of air and other non-flammable and non-aggressive gases.


Measuring values differential pressure, volume flow
Output voltage VV 0..10 V or 0..5 V min. load 10 kΩ
Output Amp AA 4..20 mA, max. load 500 Ω

Output switch contact Relay 2 floating contacts for 24 V ~ or 24 V = / 3 A

Power supply VV 15..35 V = or 19..29 V ~

AA 15..35 V =

Relay 15..35 V = or 19..29 V ~

Power consumption max. 2,3 W (24 V =) | 4,3 VA (24 V ~)

Meas. range Pressure am Gerät einstellbar

Type 250 0..+25 | 0..+50 | 0..+100 | 0..+250 | -25..+25 | -50..+50 | -100..+100 | -150..+150 Pa

Type 2500 -100..+100 | 0..+100 | 0..+250 | 0..+500 | 0..+1000 | 0..+1500 | 0..+2000 | 0..+2500 Pa

Type 7500 0..+1000 | 0..+1500 | 0..+2000 | 0..+2500 | 0..+3000 | 0..+4000 | 0..+5000 | 0..+7000 Pa

Accuracy Pressure deviation from calibration reference device (calibrator)

Type 250 ±1 Pa at range <250 Pa

Type 2500 ±5 Pa at range <500 Pa, ±10 Pa at range >500 Pa

Type 7500 ±10 Pa at range <2000 Pa, ±25 Pa at range >2000 Pa

Max. working over- 40 kPa


pressure
Calibration manually
automatic zero-point calibration (optional)
Semsor piezo measuring element

Display LCD 29x35 mm with RGB backlight


units pressure: Pa, inchWC, volume flow: m3/h, cfm (configurable)
Enclosure enclosure USE-L, PC, pure white, with removeable cable entry

Protection IP65 according to DIN EN 60529

Cable entry VV M16, for wire max. Ø=8 mm

AA M16, for wire max. Ø=8 mm

Relay M20, for wire max. Ø=10 mm


seal insert for double cable entry for wire max Ø=6 mm
Connection electrical removeable plug-in terminal, max. 2,5 mm²
Connection mech. pressure connection male Ø=5,0 mm / Ø=6,3 mm, connection tube: PVC, soft
Ambient condition -10..+50 °C, max. 85% rH short term condensation
Mounting screw mounted onto flat surface, prepared for mounting on DIN rail TS35 (35x7,5 mm) according to
EN 60715

170 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Pressure measuring transduce DPA+ xx
NEU
NEW

With LCD Type Art.-No.
Type 250
DS-DPA250+ LCD VV DS-1650729
DS-DPA250+ LCD VV AZ DS-1650730
DS-DPA250+ LCD AA DS-1650733
DS-DPA250+ LCD AA AZ DS-1650734
DS-DPA250+ LCD VV+R DS-1650737
DS-DPA250+ LCD VV+R AZ DS-1650738
Type 2500
DS-DPA2500+ LCD VV DS-1650741
DS-DPA2500+ LCD VV AZ DS-1650742
DS-DPA2500+ LCD AA DS-1650745
DS-DPA2500+ LCD AA AZ DS-1650746
DS-DPA2500+ LCD VV+R DS-1650749
DS-DPA2500+ LCD VV+R AZ DS-1650750
Type 7500
DS-DPA7500+ LCD VV DS-1650753
DS-DPA7500+ LCD VV AZ DS-1650754
DS-DPA7500+ LCD AA DS-1650757
DS-DPA7500+ LCD AA AZ DS-1650758
DS-DPA7500+ LCD VV+R DS-1650761
DS-DPA7500+ LCD VV+R AZ DS-1650762

Dimensions

C 2018 - Technical changes excepted. Pictured products similar. 171


NEU
WK01+ 24 V Sensors
NEW


WK01+ 24 V
Condensation sensor
Condensation sensor with LED signal designed to provide a switched output signal
to prevent condensation on chilled surfaces such as chilled beams. With signaling
LED and relay contact for control and monitoring applications or for series connec-
tion with the cooling valve in order to interrupt the cooling water flow directly at the
beginning of condensation.
Measuring values Humidity
Output switch contact changeover contact, 24 V: max. 24 V / 1,0 A (resistive,
floating)
Power supply 15..24 V = (±10%) or 24 V ~ (±10%)
Power consumption typ. 0,8 W (24 V =) | 1,6 VA (24 V ~
Display LED green – power supply OK
LED red – condensation
Enclosure enclosure USE-S, PC, pure white, with removeable cable
entry
Protection IP65 according to DIN EN 60529
Cable entry M20 for cable max. Ø=8 mm
Connection electrical removable plug-in terminal, max. 2,5 mm²
Ambient condition -20..+60 °C, max. 85% rH short term condensation
Delivery incl. 1x syringe with therminal contact fluid

Article Type Art.-No.


Humidity Condensation sensor DS-WK01+ 24 V DS-1650122

Dimensions

Anschluss
DS-WK01+ 24 V
GND Ground
UB+ 15..35 V = or 19..29 V
NC Relay contact opener

UB+ 24 V DC - Entry for Relay contact


NO Relay contact closer

D1 LED red - dew permeation


D2 LED green - power supply OK
P1 Potentiometer for adaption of break-over-
point
+ = more sensible, – = less sensible

172 C 2018 - Technical changes excepted. Pictures similar.


Sensoren
Sensors
NEU
Sensors MWF+
NEW

MWF+
Average temperature sensor
Duct averaging temperature sensor in enclosure USE-S for measuring the average
temperature in air ducts. The sensor detects
the applied temperature value throughout the entire length. Mounting angles for
uncomplicated duct mounting are included in
delivery.
Measuring values Temperature
Output passive, Pt1000
Measuring range -50..+80 °C
Accuracy ±0,4 K (typ. at 0 °C)
Enclosure enclosure USE-S, PC, pure white, with removable cable
entry
Protection IP65 according to DIN EN 60529
Connection electrical removable plug-in terminal, max. 2,5 mm²
Cable entry M16 for cable max. Ø=0.8 mm
Ambient condition -35..+70 °C, max. 85% rH
short term condensation
Delivery mounting flange MF6 flexible
incl. inserts for Ø=4 | 6 | 7 mm
Mounting angle set

Article Type Art.-No.


Sensor rod Length: 3000 mm DS-MWF+ 3000.Pt1000 DS-1670027
Sensor rod Length: 6000 mm DS-MWF+ 6000.Pt1000 DS-1670041

Dimensions Connection

Mounting flange

C 2018 - Technical changes excepted. Pictured products similar. 173


Frost protection thermostat FST

Article Type Art.-No.


Frost protection thermostat
for downstream temperature control of
water- and air heater due to prevention of
frost damages in ventilation- and air conditioning systems.

Set range of desired values -10°C .. +12°C


(factory setting 5°C)
Differential gap 2°C +/- 1°C
Reproducibility +/- 0,5°C
Sensor-response length approx. 60 cm
Switching output changeover contact
250 V AC, max. 10 A
Reset automatically
Allowed medium air
Housing material PC
Capillary material copper
Connector screw terminal, max. 2,5 mm²
Cable entry M20
Ambient temperature adjusted desired value
+ at least 2K .. 70°C
Housing protection IP65
Scope of delivery incl. mounting brackets
Capillary pipe length 3m DS-FST3 DS-1650107
Capillary pipe length 6m DS-FST6 DS-1650108
Capillary pipe length 12 m DS-FST12 DS-1650109

Description Connection
The switch in frost protection thermostat responds when the
temperature in a capillary tube with a length of a least 60 cm The temperature setpoint can be adjusted
falls below the temperature setpoint (closes contact C-2). manually by turning the adjustment knob with the
Contact C-3 opens at the same time and can be used as a scale after unscrewing the transparent lid. The
signal contact. The reset takes place automatically (contact frost protection switch requires no maintenance.
closes C-3) when the temperature rises above the setpoint.
The TFR xx is „intrinsically safe“, which means that in case of
a damage to the capillary membrane system, it automatically C-3 normal operation
switches to the heating function. Contact C-2 closes and can C-2 danger of frost /
therefore be used as a working contact. The air temperature sensor is interrupted
is measured over the entire sensor length (capillary tube).
The gas (R 507) filled membrane system and the capillary
tube form a measuring unit. It is mechanically coupled to the
microswitch. Dimensions

174 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors Various

Article Type Art.-No.


Remote control unit Design sample
with and w/o room temperature sensor, for wall mounting in
attractive design housing to match switch programmes by
Busch-Jaeger, Merten, Gira, Berker, Jung and Siemens.

Numerous variants in several versions:

Potentiometer
Control button Busch Jaeger
LEDs white special
Step switch inscription
Infrared detector

Multisensor for assessing of presence and brightness DS-MDS-S1 DS-1650510

The ceiling multi sensor MDS is designed for motion and


light detection in room and office spaces. Due to the flat con-
truction, the device is specially suitable for an inconspicuous
installation in ceilings.

Motion sensor 4-element PIR (passive infrared),


with status LED for
motiondetection
Output motion PIR-motion sensor 360°
with relay output
open contact, max. 24 V, 1 A
Light sensor 0 .. 1kLux, photo diode incl.
green filter, Accuray typ. ±50Lux
Output light Active light sensor 0 .. 10 V
Ambient temperature 0°C .. 50°C
Power supply 15 .. 24 V DC (+/-10%)
24 V AC (+/-10%)
Power consumption 1,2 W, 4 VA
Montage max. ceiling height of 2,70 m
Terminal Pluggable screw terminal,
max. 1,5 mm²
Housing Basic housing
material ABS, color orange
front panel
material ABS, color pure white
Protection IP20

Dimensions Connection

Motion dectection with adjustable


delay time 1s...30 min

C 2018 - Technical changes excepted. Pictured products similar. 175


Wireless sensors Sensors

Article Type Art.-No.


Wireless room sensor

Battery-and wireless room sensor for temperature and


ventilation control in connection with the receiving inter-
faces SRC-x and higher-graded control systems.
Innovative solar technology provides the energy for our
modern wireless system. The sensors require neither a
battery nor external power.
General certification for the radio system is valid for EC
countries plus Switzerland.
Data transfer to the receiver via radio telegrams acc. to
EnOcean standard. Device comes with integrated temp
sensor, rotary switch for desired value setting and pre-
sence switch (depending on type of device).
Internal solar-powered energy storage for service-free
operation.

Technical data
Technology EnOcean, (IEC 14543-3-10)
Radio frequency 868,3 Mhz
Range approx. 30m in buildings,
approx. 300m in open area
Temperature sensing Range: 0°C...40°C,
Resolution 0.15K
Abs. accuracy typical +/0,4K
Meas. data assessment every 100 sec.
Energy supply Solar cell, internal goldcap,
service-free
Housing ABS (ASA),
Color white, similar RAL9010
Protection IP30 acc. to EN60529
Ambient temp. 0..+40 °C,
max. 85% rH non-condensinge-
Wight 50g

Wireless room temperature sensor DS-SR041 DS-1650070

Wireless room temperature sensor DS-SR04P1 DS-1650071


with set point adjustment

other types on request

1
Delivery time on request, no stock items

176 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors Wireless sensors

Article Type Art.-No.


Receiver for wireless sensors

This receiver connects wireless sensors via the standard


interface 0-10V or potential-free relay contacts, respec-
tively. The receiver features analog outputs and relay
outputs.
Delivery includes configuration software for our range of
wireless sensors as well as for other EnOcean-conform
devices which are entered into the receiver.
The analog/digital outputs are allocated to the entered
sensors. For instance, 4 wireless temperature sensors
type SR04 can be entered. The measured temp. value
from these sensors are relayed analog via 0-10V.
The configuration software will run on any PC with
operating systems such as Windows XP, Windows NT,
Windows 2000 etc.. The configuration is effected via a
standard USB interface.

Technical data of hardware


Supply voltage 230VAC 50/60Hz
Power consumption max. 5VA
Outputs 4 analog outputs 0-10V
(load max. 10mA)
Relay outputs up to 4 relay outputs
(change-over, 230V/6A)
Antenna External antenna with
magnetic base plate
Antenna with 2.5 m connecting
cable included
Connection via FME port
Housing ABS, light grey, similar RAL7035
Protection IP20
Ambient tem. 0...60°C
Rel. Air humidity 0...75%rh, non-condensating
Transport/storage -20...70°C

Receiver for wireless sensors with DS-SR0-AD0 4AA/2DA1 DS-1650072


4 analog and 2 digital outputs
Receiver for wireless sensors with DS-SR0-AD0 4AA/4DA1 DS-1650073
4 analog and 4 digital outputs

Antenna extension cable


Note:
Only one antenna cable extension may be used..
Antenna cable extension DS-ANT101 DS-1650074
for receiver type: DS-SRC-ADOx,
DS-STC65-MODBUS, DS-SRC65-BACnet
Length: 10 m
Antenna cable extension DS-ANT201 DS-1650075
for receiver type: DS-SRC-ADOx, DS-SRC65-MODBUS,
DS-STC65-BACnet
Length: 20 m

1
Delivery time on request, no stock items

C 2018 - Technical changes excepted. Pictured products similar. 177


Wireless sensors Sensors

Article Type Art.-No.


Receiver for wireless sensors DS-STC65-MODBUS1 DS-1650124

Bidirectional receiver for linking of wireless sensors based


on EnOcean wireless technology with the OPEN control
system.

Coupling to the OPEN control system is realized via an


integrated RS 485 interface of OPEN EMS. The MODBUS
RTU interface can be realized alternatively by an external
repeater SSU TCP/IP controller (page 110).

The necessary MODBUS master interface (page 59) can


be acquired as an option for OPEN EMS.

Technical data hardware


Supply voltage 15-24 V DC, 24 V AC +/-10%
Power consumption 0,6 W / 1,5 VA
Interface RS485 - MODBUS
Communication Master/Slave,
Baud rate 9600Baud/19200Baud
38400Baud/57600Baud
Terminating resistor activated via jumper
Antenna (included in the delivery)
• External receiver antenna for
EnOcean radio telegrams
with magnetic base and
2.5 m antenna cable
Terminal screw terminal max. 1.5mm²
Housing ABS
Protection IP42
Ambient temperature -20 ... +60°C

Suitable for up to
32 receive channels
32 transmit channels
32 valve channels (actuator SAB05)
sensors with EnOcean wireless technology.

Antenna extension cable

Note:
Only one antenna cable extension may be used.

Antenna cable extension DS-ANT101 DS-1650074


for receiver type: DS-SRC-ADOx,
DS-STC65-MODBUS, DS-SRC65-BACnet
Length: 10 m
Antenna cable extension DS-ANT201 DS-1650075
for receiver type: DS-SRC-ADOx,
DS-STC65-MODBUS, DS-SRC65-BACnet
Length: 20 m

1
Delivery time on request, no stock items

178 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors Wireless sensors

Article Type Art.-No.


Receiver for wireless sensors DS-SRC65-BACnet1 DS-1650089

Receiver for wireless sensors and/or wireless switch,


based on EnOcean wireless technology. For linking on
controller and/or control systems with BACnet® MS/TP
RS485 interface. Event based transmission of all received
wireless telegrams via serial telegrams to controller and/or
control systems.

Technical data hardware


Supply voltage 15-24 V DC 24 V AC +/-10%
Power consumption typ. 1,0 W / 1,3 VA
Interface BACnet® MS/TP RS485,
Baud rate 9600, 19200, 38400, 57600,
76800 and 115200 Baud
configurable
Antenna (included in the delivery)
• External receiver antenna
for EnOcean
• radio telegrams
• with magnetic foot and
• 2.5 m antenna cable
Connector via FME socket
Terminal screw terminal
max. 1mm² fine stranded wire
max. 1.5mm² solid wire
Housing
Lower part Material PA6, color white
Lid Material PC, color crystal clear
Protection IP42
Ambient temperature -20 ... +60°C
Suitable for up to 32 sensors with EnOcean wireless tech-
nology
Antenna extension cable

Note:
Only one antenna cable extension may be used..

Antenna cable extension DS-ANT101 DS-1650074


for receiver type: DS-SRC-ADOx,
DS-STC65-MODBUS, DS-SRC65-BACnet
Length: 10 m
Antenna cable extension DS-ANT201 DS-1650075
for receiver type: DS-SRC-ADOx,
DS-STC65-MODBUS, DS-SRC65-BACnet
Length: 20 m

1
Delivery time on request, no stock items

C 2018 - Technical changes excepted. Pictured products similar. 179


Immersion sleeves Sensors

Article Type Art.-No.


Immersion sleeves, brass, nickel coated
with core diameter 6 mm

• pressure-fast to 16 bar
• thread R1/2“
• material CuZn37
• width across flat SW22
• operating temperature max. +130°C
Lenght (L) 50 mm Mounting length (EL) 50 mm DS-THMS050.06 DS-1650720
Lenght (L) 100 mm Mounting length (EL) 92 mm DS-THMS100.06 DS-1650721
Lenght (L) 150 mm Mounting length (EL) 142 mm DS-THMS150.06 DS-1650722
Lenght (L) 200 mm Mounting length (EL) 192 mm DS-THMS200.06 DS-1650723
Lenght (L) 250 mm Mounting length (EL) 242 mm DS-THMS250.06 DS-1650724
Lenght (L) 300 mm Mounting length (EL) 292 mm DS-THMS300.06 DS-1650725
Lenght (L) 450 mm Mounting length (EL) 442 mm DS-THMS450.06 DS-1650726

Immersion sleeves, stainless steel 1.4571


with core diameter 6 mm

• pressure-fast to 40 bar
• material V4A
• thread G1/2“
• width across flat SW27
• operating temperature max. +200°C
Lenght (L) 50 mm Mounting length (EL) 50 mm DS-THVA050.06 DS-1650710
Lenght (L) 100 mm Mounting length (EL) 92 mm DS-THVA100.06 DS-1650711
Lenght (L) 150 mm Mounting length (EL) 142 mm DS-THVA150.06 DS-1650712
Lenght (L) 200 mm Mounting length (EL) 192 mm DS-THVA200.06 DS-1650713
Lenght (L) 250 mm Mounting length (EL) 242 mm DS-THVA250.06 DS-1650714
Lenght (L) 300 mm Mounting length (EL) 292 mm DS-THVA300.06 DS-1650715
Lenght (L) 450 mm Mounting length (EL) 442 mm DS-THVA450.06 DS-1650716

Dimensions THMS Dimensions THVA

180 C 2018 - Technical changes excepted. Pictures similar.


Sensors
NEU
Sensors Accessories
NEW

Article Type Art.-No.


Clamp for contact temperature sensor DS-SPS110 DS-1650565
incl. syringe with thermal contact fluid

for pipes from 40 mm up to 110 mm diameter

Clamp for contact temperature sensor DS-SPS250 DS-1650566


incl. syringe with thermal contact fluid

for pipes up to 250 mm diameter

PA tightening strap for contact temperature sensor DS-SPS100 DS-1650567


incl. syringe with thermal contact fluid

for pipes up to 100 mm diameter

Sun and rain protection DS-ATF/protection DS-1650001


for outside air temperature sensor. DS-ATF

stainless steel 1.4301

Ball-proof protection DS-RTF/protection DS-1650520


Protection against mechanical influences
for room temperature sensors DS-Rxx.A

stainless steel 1.4301

Dimensions ATF/protection Dimensions RTF/protection

C 2018 - Technical changes excepted. Pictured products similar. 181


Measurement chart Sensors

Measuring element LM Note: The voltage values have to be measured in a connected


state under operating conditions with a mulitmeter.

t[°C] V [Volt] t[°C] V [Volt] t[°C] V [Volt] t[°C] V [Volt] t[°C] V [Volt]
-50.0 °C 2.232 V -10.0 °C 2.632 V 30.0 °C 3.032 V 70.0 °C 3.432 V 110.0 °C 3.832 V
-49.0 °C 2.242 V -9.0 °C 2.642 V 31.0 °C 3.042 V 71.0 °C 3.442 V 111.0 °C 3.842 V
-48.0 °C 2.252 V -8.0 °C 2.652 V 32.0 °C 3.052 V 72.0 °C 3.452 V 112.0 °C 3.852 V
-47.0 °C 2.262 V -7.0 °C 2.662 V 33.0 °C 3.062 V 73.0 °C 3.462 V 113.0 °C 3.862 V
-46.0 °C 2.272 V -6.0 °C 2.672 V 34.0 °C 3.072 V 74.0 °C 3.472 V 114.0 °C 3.872 V
-45.0 °C 2.282 V -5.0 °C 2.682 V 35.0 °C 3.082 V 75.0 °C 3.482 V 115.0 °C 3.882 V
-44.0 °C 2.292 V -4.0 °C 2.692 V 36.0 °C 3.092 V 76.0 °C 3.492 V 116.0 °C 3.892 V
-43.0 °C 2.302 V -3.0 °C 2.702 V 37.0 °C 3.102 V 77.0 °C 3.502 V 117.0 °C 3.902 V
-42.0 °C 2.312 V -2.0 °C 2.712 V 38.0 °C 3.112 V 78.0 °C 3.512 V 118.0 °C 3.912 V
-41.0 °C 2.322 V -1.0 °C 2.722 V 39.0 °C 3.122 V 79.0 °C 3.522 V 119.0 °C 3.922 V
-40.0 °C 2.332 V 0.0 °C 2.732 V 40.0 °C 3.132 V 80.0 °C 3.532 V 120.0 °C 3.932 V
-39.0 °C 2.342 V 1.0 °C 2.742 V 41.0 °C 3.142 V 81.0 °C 3.542 V 121.0 °C 3.942 V
-38.0 °C 2.352 V 2.0 °C 2.752 V 42.0 °C 3.152 V 82.0 °C 3.552 V 122.0 °C 3.952 V
-37.0 °C 2.362 V 3.0 °C 2.762 V 43.0 °C 3.162 V 83.0 °C 3.562 V 123.0 °C 3.962 V
-36.0 °C 2.372 V 4.0 °C 2.772 V 44.0 °C 3.172 V 84.0 °C 3.572 V 124.0 °C 3.972 V
-35.0 °C 2.382 V 5.0 °C 2.782 V 45.0 °C 3.182 V 85.0 °C 3.582 V 125.0 °C 3.982 V
-34.0 °C 2.392 V 6.0 °C 2.792 V 46.0 °C 3.192 V 86.0 °C 3.592 V 126.0 °C 3.992 V
-33.0 °C 2.402 V 7.0 °C 2.802 V 47.0 °C 3.202 V 87.0 °C 3.602 V 127.0 °C 4.002 V
-32.0 °C 2.412 V 8.0 °C 2.812 V 48.0 °C 3.212 V 88.0 °C 3.612 V 128.0 °C 4.012 V
-31.0 °C 2.422 V 9.0 °C 2.822 V 49.0 °C 3.222 V 89.0 °C 3.622 V 129.0 °C 4.022 V
-30.0 °C 2.432 V 10.0 °C 2.832 V 50.0 °C 3.232 V 90.0 °C 3.632 V 130.0 °C 4.032 V
-29.0 °C 2.442 V 11.0 °C 2.842 V 51.0 °C 3.242 V 91.0 °C 3.642 V
-28.0 °C 2.452 V 12.0 °C 2.852 V 52.0 °C 3.252 V 92.0 °C 3.652 V
-27.0 °C 2.462 V 13.0 °C 2.862 V 53.0 °C 3.262 V 93.0 °C 3.662 V
-26.0 °C 2.472 V 14.0 °C 2.872 V 54.0 °C 3.272 V 94.0 °C 3.672 V
-25.0 °C 2.482 V 15.0 °C 2.882 V 55.0 °C 3.282 V 95.0 °C 3.682 V
-24.0 °C 2.492 V 16.0 °C 2.892 V 56.0 °C 3.292 V 96.0 °C 3.692 V
-23.0 °C 2.502 V 17.0 °C 2.902 V 57.0 °C 3.302 V 97.0 °C 3.702 V
-22.0 °C 2.512 V 18.0 °C 2.912 V 58.0 °C 3.312 V 98.0 °C 3.712 V
-21.0 °C 2.522 V 19.0 °C 2.922 V 59.0 °C 3.322 V 99.0 °C 3.722 V
-20.0 °C 2.532 V 20.0 °C 2.932 V 60.0 °C 3.332 V 100.0 °C 3.732 V
-19.0 °C 2.542 V 21.0 °C 2.942 V 61.0 °C 3.342 V 101.0 °C 3.742 V
-18.0 °C 2.552 V 22.0 °C 2.952 V 62.0 °C 3.352 V 102.0 °C 3.752 V
-17.0 °C 2.562 V 23.0 °C 2.962 V 63.0 °C 3.362 V 103.0 °C 3.762 V
-16.0 °C 2.572 V 24.0 °C 2.972 V 64.0 °C 3.372 V 104.0 °C 3.772 V
-15.0 °C 2.582 V 25.0 °C 2.982 V 65.0 °C 3.382 V 105.0 °C 3.782 V
-14.0 °C 2.592 V 26.0 °C 2.992 V 66.0 °C 3.392 V 106.0 °C 3.792 V
-13.0 °C 2.602 V 27.0 °C 3.002 V 67.0 °C 3.402 V 107.0 °C 3.802 V
-12.0 °C 2.612 V 28.0 °C 3.012 V 68.0 °C 3.412 V 108.0 °C 3.812 V
-11.0 °C 2.622 V 29.0 °C 3.022 V 69.0 °C 3.422 V 109.0 °C 3.822 V

182 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Sensors Measurement chart

Measuring element Pt1000 Note: The resistance have to be measured with a resistance measuring device
(e.g. multimeter). Therefore at least one connection vein must be clamped from
the control system.
t[°C] R [Ohm] t[°C] R [Ohm] t[°C] R [Ohm] t[°C] R [Ohm] t[°C] R [Ohm]
-50 °C 803,15 -7 °C 972,62 36 °C 1139,94 79 °C 1305,11 122 °C 1468,14
-49 °C 807,11 -6 °C 976,53 37 °C 1143,80 80 °C 1308,93 123 °C 1471,91
-48 °C 811,08 -5 °C 980,45 38 °C 1147,67 81 °C 1312,74 124 °C 1475,67
-47 °C 815,04 -4 °C 984,36 39 °C 1151,53 82 °C 1316,56 125 °C 1479,44
-46 °C 819,00 -3 °C 988,27 40 °C 1155,39 83 °C 1320,37 126 °C 1483,20
-45 °C 822,96 -2 °C 992,18 41 °C 1159,25 84 °C 1324,18 127 °C 1486,96
-44 °C 826,92 -1 °C 996,09 42 °C 1163,11 85 °C 1327,99 128 °C 1490,72
-43 °C 830,88 0 °C 1000,00 43 °C 1166,97 86 °C 1331,80 129 °C 1494,48
-42 °C 834,84 1 °C 1003,91 44 °C 1170,83 87 °C 1335,61 130 °C 1498,24
-41 °C 838,80 2 °C 1007,81 45 °C 1174,69 88 °C 1339,41 131 °C 1501,99
-40 °C 842,75 3 °C 1011,72 46 °C 1178,54 89 °C 1343,22 132 °C 1505,75
-39 °C 846,70 4 °C 1015,62 47 °C 1182,40 90 °C 1347,02 133 °C 1509,50
-38 °C 850,66 5 °C 1019,53 48 °C 1186,25 91 °C 1350,83 134 °C 1513,26
-37 °C 854,61 6 °C 1023,43 49 °C 1190,10 92 °C 1354,63 135 °C 1517,01
-36 °C 858,56 7 °C 1027,33 50 °C 1193,95 93 °C 1358,43 136 °C 1520,76
-35 °C 862,51 8 °C 1031,23 51 °C 1197,80 94 °C 1362,23 137 °C 1524,51
-34 °C 866,46 9 °C 1035,13 52 °C 1201,65 95 °C 1366,03 138 °C 1528,26
-33 °C 870,40 10 °C 1039,02 53 °C 1205,50 96 °C 1369,82 139 °C 1532,00
-32 °C 874,35 11 °C 1042,92 54 °C 1209,34 97 °C 1373,62 140 °C 1535,75
-31 °C 878,29 12 °C 1046,81 55 °C 1213,19 98 °C 1377,41 141 °C 1539,50
-30 °C 882,24 13 °C 1050,71 56 °C 1217,03 99 °C 1381,21 142 °C 1543,24
-29 °C 886,18 14 °C 1054,60 57 °C 1220,87 100 °C 1385,00 143 °C 1546,98
-28 °C 890,12 15 °C 1058,49 58 °C 1224,71 101 °C 1388,79 144 °C 1550,72
-27 °C 894,06 16 °C 1062,38 59 °C 1228,55 102 °C 1392,58 145 °C 1554,46
-26 °C 898,00 17 °C 1066,27 60 °C 1232,39 103 °C 1396,37 146 °C 1558,20
-25 °C 901,94 18 °C 1070,16 61 °C 1236,23 104 °C 1400,16 147 °C 1561,94
-24 °C 905,87 19 °C 1074,04 62 °C 1240,07 105 °C 1403,95 148 °C 1565,68
-23 °C 909,81 20 °C 1077,93 63 °C 1243,90 106 °C 1407,73 149 °C 1569,41
-22 °C 913,74 21 °C 1081,81 64 °C 1247,74 107 °C 1411,52 150 °C 1573,15
-21 °C 917,68 22 °C 1085,70 65 °C 1251,57 108 °C 1415,30 151 °C 1576,88
-20 °C 921,61 23 °C 1089,58 66 °C 1255,40 109 °C 1419,08 152 °C 1580,61
-19 °C 925,54 24 °C 1093,46 67 °C 1259,23 110 °C 1422,86 153 °C 1584,35
-18 °C 929,47 25 °C 1097,34 68 °C 1263,06 111 °C 1426,64 154 °C 1588,08
-17 °C 933,40 26 °C 1101,22 69 °C 1266,89 112 °C 1430,42 155 °C 1591,80
-16 °C 937,32 27 °C 1105,09 70 °C 1270,72 113 °C 1434,20 156 °C 1595,53
-15 °C 941,25 28 °C 1108,97 71 °C 1274,54 114 °C 1437,97 157 °C 1599,26
-14 °C 945,17 29 °C 1112,84 72 °C 1278,37 115 °C 1441,75 158 °C 1602,98
-13 °C 949,10 30 °C 1116,72 73 °C 1282,19 116 °C 1445,52 159 °C 1606,71
-12 °C 953,02 31 °C 1120,59 74 °C 1286,02 117 °C 1449,30 160 °C 1610,43
-11 °C 956,94 32 °C 1124,46 75 °C 1289,84 118 °C 1453,07
-10 °C 960,86 33 °C 1128,33 76 °C 1293,66 119 °C 1456,84
-9 °C 964,78 34 °C 1132,20 77 °C 1297,48 120 °C 1460,61
-8 °C 968,70 35 °C 1136,07 78 °C 1301,30 121 °C 1464,38

C 2018 - Technical changes excepted. Pictured products similar. 183


KRM-x-DZ Duct Smoke Sensor

The KRM-DZ duct smoke detector is designed for smoke


detection in ventilation ducts. It constitutes a combination of
a smoke detector with an adapter system, whose measuring
tube and housing have been specially adapted for optimal air
flow through the smoke detector.

• DIBt approval No. Z-78.6-200 for control of


fire/smoke protection flaps

• VdS certification (G210148)


• Patented single tube air sampling system
• Contamination display in % and
signalling at 70 %
• Electronic air flow control
• Externally operable reset button in the housing
• Remote reset option via terminals
• Long service life, low contamination
• Annual service interval

Technical Information Technical Information


Sensor Scattering RM 3.3 (ALK-E) Approvals
Supply voltage KRM-1-DZ: Sensing chamber and
230 V AC ± 10 %, 50/60 Hz air duct frames DIBt approval Z-78.6-200
Supply voltage KRM-2-DZ VdS certifi cation G210148
24 V AC/DC +15 % / -10 % Tested according to FprEN54-27
Rated current KRM-1-DZ: 30 mA LED Display % contamination level
KRM-2-DZ : 140 mA flashes at > 70 %
Relay outputs floating LED in housing green operating
Alarm relay locked 1 changeover contact, blue lack of air fl ow
8 A, 250 V AC od. 24 V DC yellow failure, electronics,
1 NC, 8 A, 250 V AC od. 24 V DC smoke detector defective,
Contamination relay 1 NC contact, low voltage red smoke alarm, including
6 A, 250 V AC od. 24 V DC contamination > 99 %,,
System failure relay 1 NC contact, flashes at attempts to
6 A, 250 V AC od. 24 V DC release when the sensing
Air fl ow relay 1 NC contact, chamber is not empty
6 A, 250 V AC od. 24 V DC Adapter housing ABS
Operating temperature -15 °C .. +50 °C Air measuring tube Aluminium / plastic
Permissible humidity 10 .. 95 % non-condensing shortest length 160 mm
Protection class IP 54, with WDG IP 65 standard length 600 mm
Dimensions (L x W x H) 257 x 166 x 77 mm
Screw connection 3 x M16

Article Type Art.-No.


Duct smoke detector with DS-KRM-1-DZ DS-1650655
DIBt approval for control of fire/smoke protection flaps

Supply voltage: 230 V AC


Duct smoke detector with DS-KRM-2-DZ DS-1650656
DIBt approval for control of fire/smoke protection flaps

Supply voltage: 24 V AC / DC

Accessories refer to see page 187

184 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Duct Smoke Sensor KRM-x-DZ

Connection KRM-1-DZ (230 V AC)1

Connection fire/smoke protection flaps 24 V AC / DC Connection fire/smoke protection flaps 230 V AC

Dimensions front view

Connection KRM-2-DZ (24 V AC / DC)1


Note:
By connection with 24 volt an approved power supply corresponding
to fire protection ordinance has to be used!

Dimensions side view

Measurements in mm.

1
Note: All contact depictions are with the power off (alarm) / no air flow present.
The floating switching contacts (terminals 11 – 21) are uniformly assigned to an installation category according to EN 60730-1.
These switching contacts are only to be used for 230 V AC or 24 V AC/DC, a combination is not permitted.

C 2018 - Technical changes excepted. Pictured products similar. 185


KRM-x Duct Smoke Sensor

The KRM duct smoke detector is designed for smoke detection


in ventilation ducts. It constitutes a combination of a smoke
detector with an adapter system, whose measuring tube and
housing have been specially adapted for optimal air flow
through the smoke detector.

• VdS certifi cation (G210059)


• Patented single tube air sampling system
• Contamination display in %
and signalling at 70 %
• Electronic air flow control
• Externally operable reset button in the
• housing
• Remote reset option via terminals
• Long service life, low contamination

Technical Information
Sensor Scattering RM 3.3 (ALK-E) Approvals
Supply voltage KRM-1 Sensing chamber and
230 V AC ± 10 %, 50/60 Hz air duct frames VdS certifi cation G210148
Supply voltage KRM-2 Tested according to FprEN54-27
24 V AC/DC +15 % / -10 % LED Display % contamination level
Rated current KRM-1: 30 mA flashes at > 70 %
KRM-2: 120 mA LED in housing green operating
Relay outputs floating blue lack of air fl ow
Alarm relay locked 1 changeover contact, yellow failure, electronics,
8 A, 250 V AC od. 24 V DC smoke detector defective,
1 NC, 8 A, 250 V AC od. 24 V DC low voltage red smoke alarm, including
Contamination relay 1 NC contact, contamination > 99 %,,
6 A, 250 V AC od. 24 V DC flashes at attempts to
Operating temperature -15 °C .. +50 °C release when the sensing
Permissible humidity 10 .. 95 % non-condensing chamber is not empty
Protection class: IP 54, with WDG IP 65 Adapter housing ABS
Air measuring tube Aluminium / plastic
shortest length 160 mm
standard length 600 mm
Dimensions (L x W x H) 257 x 166 x 77 mm
Screw connection 3 x M16

Article Type Art.-No.


duct smoke detector DS-KRM-1 DS-1650657

Supply voltage: 230 V AC

duct smoke detector DS-KRM-2 DS-1650658

Supply voltage: 24 V AC / DC

Accessories refer to see page 187

186 C 2018 - Technical changes excepted. Pictures similar.


Sensors
Duct Smoke Sensor KRM-x

Connection KRM-1 (230 V AC)1 Dimensions front view

Connection KRM-2 (24 V AC / DC)1 Dimensions side view

Measurements in mm

1
Note: All contact depictions are with the power off (alarm) / no air flow present.
The floating switching contacts (terminals 11 – 17) are uniformly assigned to an installation category according to EN 60730-1.
These switching contacts are only to be used for 230 V AC or 24 V AC/DC, a combination is not permitted.

Article Type Art.-No.


Accessories duct smoke detector DS-KRMx / DS-KRMx-DZ
Housing impermeable to splash-water for smoke detector DS-KRMx DS-WDG DS-1650659
Construction panel KS DS-KS DS-1650660
for mounting of duct smoke sensor DS-KRMx
on round or isolated ducts
Construction panel KS DS-KS-WDG DS-1650661
for mounting of duct smoke sensor DS-KRMx in housing
impermeable to splash-water on round or isolated ducts

C 2018 - Technical changes excepted. Pictured products similar. 187


Notice

188 C 2018 - Technical changes excepted. Pictures similar.


Valves / Actuators
Valves and Actuators
Valves and Actuators Page
Information for bus capable actuators 190
Valves and Actuators 192
Control ball valves 208
Open-Close ball valves 214
6-way Control ball valves 216
Pipe screw fittings 218
Zone valves 219
Thermoelectrical actuators 220
Air flap drives 224
Accessories 227
Throttling valves 228

C 2018 - Technical changes excepted. Pictured products similar. 189


Information about actuators with CAN-bus interface

Control ball valves with additional CAN-bus interface

Actuators for control ball valves, which are equipped with a CAN-bus interface,
additionally contain the following inputs in the actuator.

Sensor input 1 - selectable LM: -20 .. +120 °C (10mV/K)


or digital input (switching against GND)

Sensor input 2 - selectable LM: -20 .. +120 °C (10mV/K)


or digital input (switching against GND)

Sensor input 3 - selectable Analog input 0 .. 10 V


or manual control 2 .. 10 V
or force OPEN / CLOSE

Control panel
The actuation of the additional inputs takes place by CAN-bus 10 .. 50 kBit/s, System OPEN.

Damper actuators with additional CAN-bus interface

Actuators for damper actuators, which are equipped with a CAN-bus interface,
additionally contain the following inputs in the actuator.

Sensor input 1 - selectable LM: -20 .. +120 °C (10mV/K)


or digital input (switching against GND)

Sensor input 2 - selectable LM: -20 .. +120 °C (10mV/K)


or digital input (switching against GND)

Sensor input 3 - selectable Analog input 0 .. 10 V


or manual control 2 .. 10 V
or force OPEN / Close

Control panel
The actuation of the additional inputs takes place by CAN-bus 10 .. 50 kBit/s, System OPEN.

Actuators with additional CAN-bus interface

Actuators, which are equipped with a CAN-bus interface,


additionally contain the following inputs in the actuator.

Sensor input 1 - selectable LM: -20 .. +120 °C (10mV/K)


or digital input (switching against GND)

Sensor input 2 - selectable LM: -20 .. +120 °C (10mV/K)


or digital input (switching against GND)

Sensor input 3 - selectable Analog input 0 .. 10 V


or manual control 2 .. 10 V
or force OPEN / Close

Control panel
The actuation of the additional inputs takes place by CAN-bus 10 .. 50 kBit/s, System OPEN.

190 C 2018 - Technical changes excepted. Pictures similar.


Information about actuators with BACnet® MS/TP interface

Control ball valves with additional BACnet® MS/TP interface

Actuators for control ball valves, which are equipped with a BACnet® MS/TP interface,

Valves / Actuators
additionally contain the following inputs in the actuator.
Sensor input 1 - selectable Pt1000 -20 .. +120°C
or Ni1000 DIN -15 .. +75°C
or Ni1000 Tk5000 -15 .. +90°C
or digital input (switching against GND)

Sensor input 2 - selectable Pt1000 -20 .. +120°C


or Ni1000 DIN -15 .. +75°C
or Ni1000 Tk5000 -15 .. +90°C
or digital input (switching against GND)

Sensor input 3 - selectable analog input: 0 ... 10 V Control panel


or manual control: 2 .. 10 V The actuation of the additional inputs takes
or force OPEN / CLOSE place by BACnet® MS/TP 2400 .. 115200 Baud.

Damper actuators with additional BACnet® MS/TP interface

Actuators for control ball valves, which are equipped with a BACnet® MS/TP interface,
additionally contain the following inputs in the actuator.
Sensor input 1 - selectable Pt1000 -20 .. +120°C
or Ni1000 DIN -15 .. +75°C
or Ni1000 Tk5000 -15 .. +90°C
or digital input (switching against GND)

Sensor input 2 - selectable Pt1000 -20 .. +120°C


or Ni1000 DIN -15 .. +75°C
or Ni1000 Tk5000 -15 .. +90°C
or digital input (switching against GND)

Sensor input 3 - selectable analog input: 0 ... 10 V Control panel


or manual control: 2 .. 10 V The actuation of the additional inputs takes
or force OPEN / CLOSE place by BACnet® MS/TP 2400 .. 115200 Baud.

Actuators with additional BACnet® MS/TP interface

Actuators, which are equipped with a BACnet® MS/TP interface,


additionally contain the following inputs in the actuator.
Sensor input 1 - selectable Pt1000 -20 .. +120°C
or Ni1000 DIN -15 .. +75°C
or Ni1000 Tk5000 -15 .. +90°C
or digital input (switching against GND)

Sensor input 2 - selectable Pt1000 -20 .. +120°C


or Ni1000 DIN -15 .. +75°C
or Ni1000 Tk5000 -15 .. +90°C
or digital input (switching against GND)

Sensor input 3 - selectable analog input: 0 ... 10 V Control panel


or manual control: 2 .. 10 V The actuation of the additional inputs takes
or force OPEN / CLOSE place by BACnet® MS/TP 2400 .. 115200 Baud.

C 2018 - Technical changes excepted. Pictured products similar. 191


Overview Valves and Actuators

Continuous control valves


Actuators

Pressure class PN 16 PN 6 PN 16
Permissible pressure ps [kPA] 1600 600 1600

2-way valve H4..B H6..R H6..N

3-way valve H5..B H7..R H7..N

Page 188-189 190-193 194-197


Page 199 200 201

Connection
Outside thread x
Flange x x

Application in buildings1
closed circuits x x x
open circuits (pH > 7) x

Temperature of medium
5°C .. 120°C x x x
-10°C .. + 5°C
x x x
with spindle heating2

DN kvs [m³/h]
15 0.63 H4..B / H5..B H6..R / H7..R H6..N / H7..N
15 1 H4..B / H5..B H6..R / H7..R H6..N / H7..N
15 1.6 H4..B / H5..B H6..R / H7..R H6..N / H7..N
15 2.5 H4..B / H5..B H6..R / H7..R H6..N / H7..N
15 4 H4..B / H5..B H6..R / H7..R H6..N / H7..N
20 6.3 H4..B / H5..B H6..R / H7..R H6..N / H7..N
25 10 H4..B / H5..B H6..R / H7..R H6..N / H7..N
32 16 H4..B / H5..B H6..R / H7..R H6..N / H7..N
40 25 H4..B / H5..B H6..R / H7..R H6..N / H7..N
50 40 H4..B / H5..B H6..R / H7..R H6..N / H7..N
65 58 H6..R / H7..R H6..N / H7..N
80 90 H6..R / H7..R H6..N / H7..N
100 145 H6..R / H7..R H6..N / H7..N
125 220 H7..N
150 320 H7..N

1
available on request for applications in outdoor installations
2
up to DN 100
192 C 2018 - Technical changes excepted. Pictures similar.
Valves and Actuators Structural table

Valves / Actuators

pmax = max. permissible differential pressure for controller path A-AB 400 kPa H4/5...B; H6/7...N; H6/7...R.

ps = Closing pressure refer to pages 190 - 205.

C 2018 - Technical changes excepted. Pictured products similar. 193


Threaded valves - Red bronze PN 16 Valves and Actuators
constant
AC/DC 24 V

Actuators
Type DWH05-24Y DWH10-24Y DWH15-24Y DWH10-24Y-N DWH10-24Y-S
Actuator Standard Art.-No. DS-472020 DS-472021 DS-472023 DS-472024 DS-472022

Positioning force 500 N 1000 N 1500 N 1000 N 1000 N


Stroke 15 mm 20 mm 20 mm 20 mm 20 mm
Run time 150 s 150 s 150 s 150 s 35 s
Emergency function - - - x -
Run time emergency function - - - 35 s -
Control DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V
Working range / Acknowledgement DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V

Through valve with outside thread, PN 16, RG5, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H411B DS-471033 1300 1600 1600 1600 1600
15 1 H412B DS-471034 1300 1600 1600 1600 1600
15 1.6 H413B DS-471035 1300 1600 1600 1600 1600
15 2.5 H414B DS-471036 1300 1600 1600 1600 1600
15 4 H415B DS-471037 1300 1600 1600 1600 1600
20 6.3 H420B DS-471038 900 1600 1600 1600 1600
25 10 H425B DS-471039 500 1300 1600 1300 1300
32 16 H432B DS-471040 350 1000 1600 1000 1000
40 25 H440B DS-471041 150 500 900 500 500
50 40 H450B DS-471042 70 300 550 300 300

Three-way mixing valve with outside thread, PN 16, RG5, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H511B DS-471001 1300 1600 1600 1600 1600
15 1 H512B DS-471002 1300 1600 1600 1600 1600
15 1.6 H513B DS-471003 1300 1600 1600 1600 1600
15 2.5 H514B DS-471004 1300 1600 1600 1600 1600
15 4 H515B DS-471005 1300 1600 1600 1600 1600
20 6.3 H520B DS-471006 900 1600 1600 1600 1600
25 10 H525B DS-471007 500 1300 1600 1300 1300
32 16 H532B DS-471008 350 1000 1600 1000 1000
40 25 H540B DS-471009 150 500 900 500 500
50 40 H550B DS-471010 70 300 550 300 300

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

194 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Threaded valves - Red bronze PN 16
3-point
AC/DC 24 V AC 230 V

Actuators

Valves / Actuators
Type DWH05-24 DWH10-24 DWH15-24 DWH05-230 DWH10-230 DWH15-230
Actuator Standard Art.-No. DS-472028 DS-472029 DS-472030 DS-472032 DS-472033 DS-472034

Positioning force 500 N 1000 N 1500 N 500 N 1000 N 1500 N


Stroke 15 mm 20 mm 20 mm 15 mm 20 mm 20 mm
Run time 150 s 150 s 150 s 150 s 150 s 150 s
Emergency function - - - - - -
Run time emergency function - - - - - -
Control - - - - - -
Working range / Acknowledgement - - - - - -

Through valve with outside thread, PN 16, RG5, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H411B DS-471033 1300 1600 1600 1300 1600 1600
15 1 H412B DS-471034 1300 1600 1600 1300 1600 1600
15 1.6 H413B DS-471035 1300 1600 1600 1300 1600 1600
15 2.5 H414B DS-471036 1300 1600 1600 1300 1600 1600
15 4 H415B DS-471037 1300 1600 1600 1300 1600 1600
20 6.3 H420B DS-471038 900 1600 1600 900 1600 1600
25 10 H425B DS-471039 500 1300 1600 500 1300 1600
32 16 H432B DS-471040 350 1000 1600 350 1000 1600
40 25 H440B DS-471041 150 500 900 150 500 900
50 40 H450B DS-471042 70 300 550 70 300 550

Three-way mixing valve with outside thread, PN 16, RG5, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H511B DS-471001 1300 1600 1600 1300 1600 1600
15 1 H512B DS-471002 1300 1600 1600 1300 1600 1600
15 1.6 H513B DS-471003 1300 1600 1600 1300 1600 1600
15 2.5 H514B DS-471004 1300 1600 1600 1300 1600 1600
15 4 H515B DS-471005 1300 1600 1600 1300 1600 1600
20 6.3 H520B DS-471006 900 1600 1600 900 1600 1600
25 10 H525B DS-471007 500 1300 1600 500 1300 1600
32 16 H532B DS-471008 350 1000 1600 350 1000 1600
40 25 H540B DS-471009 150 500 900 150 500 900
50 40 H550B DS-471010 70 300 550 70 300 550

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

C 2018 - Technical changes excepted. Pictured products similar. 195


Flange valves PN 6 Valves and Actuators
constant
AC/DC 24 V

Actuators
Type DWH05-24Y DWH10-24Y DWH15-24Y DWH25-24Y DWH45-24Y
Actuator Standard Art.-No. DS-472020 DS-472021 DS-472023 DS-472026 DS-472027

Positioning force 500 N 1000 N1 1500 N 2500 N1 4500 N


Stroke 15 mm 20 mm 20 mm 40 mm 40 mm
Run time 150 s 150 s 150 s 150 s 150 s
Emergency function - - - - -
Run time emergency function - - - - -
Control DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V
Working range / Acknowledgement DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V

Through valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H611R DS-471044 600 600 600 - -
15 1 H612R DS-471070 600 600 600 - -
15 1.6 H613R DS-471046 600 600 600 - -
15 2.5 H614R DS-471071 600 600 600 - -
15 4 H615R DS-471048 600 600 600 - -
20 6.3 H620R DS-471050 600 600 600 - -
25 10 H625R DS-471052 500 600 600 - -
32 16 H632R DS-471054 350 600 600 - -
40 25 H640R DS-471056 150 500 600 - -
50 40 H650R DS-471058 70 300 550 - -
65 58 H664R DS-471060 - 140 280 - -
80 90 H679R DS-471062 - 80 160 - -
100 145 H6100R DS-471064 - - - 200 450

Three-way mixing valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H711R DS-471012 600 600 600 - -
15 1 H712R DS-471072 600 600 600 - -
15 1.6 H713R DS-471014 600 600 600 - -
15 2.5 H714R DS-471069 600 600 600 - -
15 4 H715R DS-471016 600 600 600 - -
20 6.3 H720R DS-471018 600 600 600 - -
25 10 H725R DS-471020 500 600 600 - -
32 16 H732R DS-471022 350 600 600 - -
40 25 H740R DS-471024 150 500 600 - -
50 40 H750R DS-471026 70 300 550 - -
65 58 H764R DS-471028 - 140 280 - -
80 90 H779R DS-471030 - 80 160 - -
100 145 H7100R DS-471032 - - - 200 450

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

196 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Flange valves PN 6
constant
AC/DC 24 V

Actuators

Valves / Actuators
Type DWH10-24Y-N DWH20-24Y-N DWH10-24Y-S
Actuator Standard Art.-No. DS-472024 DS-472025 DS-472022

Positioning force 1000 N 2000 N 1000 N1


Stroke 20 mm 32 mm 20 mm
Run time 150 s 150 s 35 s
Emergency function x x -
Run time emergency function 35 s 35 s -
Control DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V
Working range / Acknowledgement DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V

Through valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA
15 0.63 H611R DS-471044 600 - 600
15 1 H612R DS-471070 600 - 600
15 1.6 H613R DS-471046 600 - 600
15 2.5 H614R DS-471071 600 - 600
15 4 H615R DS-471048 600 - 600
20 6.3 H620R DS-471050 600 - 600
25 10 H625R DS-471052 600 - 600
32 16 H632R DS-471054 600 - 600
40 25 H640R DS-471056 500 - 500
50 40 H650R DS-471058 300 - 300
65 58 H664R DS-471060 140 - 140
80 90 H679R DS-471062 80 - 80
100 145 H6100R DS-471064 - 150 -

Three-way mixing valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA
15 0.63 H711R DS-471012 600 - 600
15 1 H712R DS-471072 600 - 600
15 1.6 H713R DS-471014 600 - 600
15 2.5 H714R DS-471069 600 - 600
15 4 H715R DS-471016 600 - 600
20 6.3 H720R DS-471018 600 - 600
25 10 H725R DS-471020 600 - 600
32 16 H732R DS-471022 600 - 600
40 25 H740R DS-471024 500 - 500
50 40 H750R DS-471026 300 - 300
65 58 H764R DS-471028 140 - 140
80 90 H779R DS-471030 80 - 80
100 145 H7100R DS-471032 - 150 -

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

C 2018 - Technical changes excepted. Pictured products similar. 197


Flange valves PN 6 Valves and Actuators
3-point
AC/DC 24 V

Actuators
Type DWH05-24 DWH10-24 DWH15-24 DWH25-24
Actuator Standard Art.-No. DS-472028 DS-472029 DS-472030 DS-472031

Positioning force 500 N 1000 N 1500 N 2500 N


Stroke 15 mm 20 mm 20 mm 40 mm
Run time 150 s 150 s 150 s 150 s
Emergency function - - - -
Run time emergency function - - - -
Control - - - -
Working range / Acknowledgement - - - -

Through valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H611R DS-471044 600 600 600 -
15 1 H612R DS-471070 600 600 600 -
15 1.6 H613R DS-471046 600 600 600 -
15 2.5 H614R DS-471071 600 600 600 -
15 4 H615R DS-471048 600 600 600 -
20 6.3 H620R DS-471050 600 600 600 -
25 10 H625R DS-471052 500 600 600 -
32 16 H632R DS-471054 350 600 600 -
40 25 H640R DS-471056 150 500 600 -
50 40 H650R DS-471058 70 300 550 -
65 58 H664R DS-471060 - 140 280 -
80 90 H679R DS-471062 - 80 160 -
100 145 H6100R DS-471064 - - - 200

Three-way mixing valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H711R DS-471012 600 600 600 -
15 1 H712R DS-471072 600 600 600 -
15 1.6 H713R DS-471014 600 600 600 -
15 2.5 H714R DS-471069 600 600 600 -
15 4 H715R DS-471016 600 600 600 -
20 6.3 H720R DS-471018 600 600 600 -
25 10 H725R DS-471020 500 600 600 -
32 16 H732R DS-471022 350 600 600 -
40 25 H740R DS-471024 150 500 600 -
50 40 H750R DS-471026 70 300 550 -
65 58 H764R DS-471028 - 140 280 -
80 90 H779R DS-471030 - 80 160 -
100 145 H7100R DS-471032 - - - 200

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

198 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Flange valves PN 6
3-point
AC 230 V

Actuators

Valves / Actuators
Type DWH05-230 DWH10-230 DWH15-230 DWH25-230
Actuator Standard Art.-No. DS-472032 DS-472033 DS-472034 DS-472035

Positioning force 500 N 1000 N 1500 N 2500 N


Stroke 15 mm 20 mm 20 mm 40 mm
Run time 150 s 150 s 150 s 150 s
Emergency function - - - -
Run time emergency function - - - -
Control - - - -
Working range / Acknowledgement - - - -

Through valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H611R DS-471044 600 600 600 -
15 1 H612R DS-471070 600 600 600 -
15 1.6 H613R DS-471046 600 600 600 -
15 2.5 H614R DS-471071 600 600 600 -
15 4 H615R DS-471048 600 600 600 -
20 6.3 H620R DS-471050 600 600 600 -
25 10 H625R DS-471052 500 600 600 -
32 16 H632R DS-471054 350 600 600 -
40 25 H640R DS-471056 150 500 600 -
50 40 H650R DS-471058 70 300 550 -
65 58 H664R DS-471060 - 140 280 -
80 90 H679R DS-471062 - 80 160 -
100 145 H6100R DS-471064 - - - 200

Three-way mixing valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H711R DS-471012 600 600 600 -
15 1 H712R DS-471072 600 600 600 -
15 1.6 H713R DS-471014 600 600 600 -
15 2.5 H714R DS-471069 600 600 600 -
15 4 H715R DS-471016 600 600 600 -
20 6.3 H720R DS-471018 600 600 600 -
25 10 H725R DS-471020 500 600 600 -
32 16 H732R DS-471022 350 600 600 -
40 25 H740R DS-471024 150 500 600 -
50 40 H750R DS-471026 701 300 550 -
65 58 H764R DS-471028 - 140 280 -
80 90 H779R DS-471030 - 80 160 -
100 145 H7100R DS-471032 - - - 200

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

C 2018 - Technical changes excepted. Pictured products similar. 199


Flange valves PN 16 Valves and Actuators
constant
AC/DC 24 V

Actuators
Type DWH05-24Y DWH10-24Y DWH15-24Y DWH25-24Y DWH45-24Y
Actuator Standard Art.-No. DS-472020 DS-472021 DS-472023 DS-472026 DS-472027

Positioning force 500 N 1000 N 1500 N 2500 N 4500 N


Stroke 15 mm 20 mm 20 mm 40 mm 40 mm
Run time 150 s 150 s 150 s 150 s 150 s
Emergency function - - - - -
Run time emergency function - - - - -
Control DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V
Working range / Acknowledgement DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V

Through valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H611N DS-471043 1300 1600 1600 - -
15 1 H612N DS-471073 1300 1600 1600 - -
15 1.6 H613N DS-471045 1300 1600 1600 - -
15 2.5 H614N DS-471074 1300 1600 1600 - -
15 4 H615N DS-471047 1300 1600 1600 - -
20 6.3 H620N DS-471049 900 1600 1600 -
25 10 H625N DS-471051 500 1300 1600 -
32 16 H632N DS-471053 350 1000 1600 -
40 25 H640N DS-471055 150 500 900 -
50 40 H650N DS-471057 70 300 550 -
65 58 H664N DS-471059 - 140 280 -
80 90 H679N DS-471061 - 80 160 -
100 145 H6100N DS-471063 - - - 200 450
125 220 H6125S DS-471065 - - - 110 250
150 320 H6150S DS-471066 - - - 70 180

Three-way mixing valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA ps kPA
15 0.63 H711N DS-471011 1300 1600 1600
15 1 H712N DS-471075 1300 1600 1600
15 1.6 H713N DS-471013 1300 1600 1600
15 2.5 H714N DS-471076 1300 1600 1600
15 4 H715N DS-471015 1300 1600 1600
20 6.3 H720N DS-471017 900 1600 1600
25 10 H725N DS-471019 500 1300 1600
32 16 H732N DS-471021 350 1000 1600
40 25 H740N DS-471023 150 500 900
50 40 H750N DS-471025 70 300 550
65 58 H764N DS-471027 - 140 280
80 90 H779N DS-471029 - 80 160
100 145 H7100N DS-471031 - - - 200 450
125 220 H7125N DS-471067 - - - 130 290
150 320 H7150N DS-471068 - - - 80 190
ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

200 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Flange valves PN 16
constant
AC/DC 24 V

Actuators

Valves / Actuators
Type DWH10-24Y-N DWH20-24Y-N DWH10-24Y-S
Actuator Standard Art.-No. DS-472024 DS-472025 DS-472022

Positioning force 1000 N 2000 N 1000 N


Stroke 20 mm 32 mm 20 mm
Run time 150 s 150 s 35 s
Emergency function x x -
Run time emergency function 35 s 35 s -
Control DC 0 .. 10 V DC 0 .. 10 V DC 0 .. 10 V
Working range / Acknowledgement DC 2 .. 10 V DC 2 .. 10 V DC 2 .. 10 V

Through valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA
15 0.63 H611N DS-471043 1600 - 1600
15 1 H612N DS-471073 1600 - 1600
15 1.6 H613N DS-471045 1600 - 1600
15 2.5 H614N DS-471074 1600 - 1600
15 4 H615N DS-471047 1600 - 1600
20 6.3 H620N DS-471049 1600 - 1600
25 10 H625N DS-471051 1300 - 1300
32 16 H632N DS-471053 1000 - 1000
40 25 H640N DS-471055 500 - 500
50 40 H650N DS-471057 300 - 300
65 58 H664N DS-471059 140 - 140
80 90 H679N DS-471061 80 - 80
100 145 H6100N DS-471063 - 150 -
125 220 H6125S DS-471065 - - -
150 320 H6150S DS-471066 - - -

Three-way mixing valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA
15 0.63 H711N DS-471011 1600 - 1600
15 1 H712N DS-471075 1600 - 1600
15 1.6 H713N DS-471013 1600 - 1600
15 2.5 H714N DS-471076 1600 - 1600
15 4 H715N DS-471015 1600 - 1600
20 6.3 H720N DS-471017 1600 - 1600
25 10 H725N DS-471019 1300 - 1300
32 16 H732N DS-471021 1000 - 1000
40 25 H740N DS-471023 500 - 500
50 40 H750N DS-471025 300 - 300
65 58 H764N DS-471027 140 - 140
80 90 H779N DS-471029 80 - 80
100 145 H7100N DS-471031 - 150 -
125 220 H7125N DS-471067 - - -
150 320 H7150N DS-471068 - - -
ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

C 2018 - Technical changes excepted. Pictured products similar. 201


Flange valves PN 16 Valves and Actuators
3-point
AC/DC 24 V

Actuators
Type DWH05-24 DWH10-24 DWH15-24 DWH25-24
Actuator Standard Art.-No. DS-472028 DS-472029 DS-472030 DS-472031

Positioning force 500 N 1000 N 1500 N 2500 N


Stroke 15 mm 20 mm 20 mm 40 mm
Run time 150 s 150 s 150 s 150 s
Emergency function - - - -
Run time emergency function - - - -
Control - - - -
Working range / Acknowledgement - - - -

Through valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H611N DS-471043 1300 1600 1600 -
15 1 H612N DS-471073 1300 1600 1600 -
15 1.6 H613N DS-471045 1300 1600 1600 -
15 2.5 H614N DS-471074 1300 1600 1600 -
15 4 H615N DS-471047 1300 1600 1600 -
20 6.3 H620N DS-471049 900 1600 1600 -
25 10 H625N DS-471051 500 1300 1600 -
32 16 H632N DS-471053 350 1000 1600 -
40 25 H640N DS-471055 150 500 900 -
50 40 H650N DS-471057 70 300 550 -
65 58 H664N DS-471059 - 140 280 -
80 90 H679N DS-471061 - 80 160 -
100 145 H6100N DS-471063 - - - 200
125 220 H6125S DS-471065 - - - 110
150 320 H6150S DS-471066 - - - 70

Three-way mixing valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H711N DS-471011 1300 1600 1600
15 1 H712N DS-471075 1300 1600 1600
15 1.6 H713N DS-471013 1300 1600 1600
15 2.5 H714N DS-471076 1300 1600 1600
15 4 H715N DS-471015 1300 1600 1600
20 6.3 H720N DS-471017 900 1600 1600
25 10 H725N DS-471019 500 1300 1600
32 16 H732N DS-471021 350 1000 1600
40 25 H740N DS-471023 150 500 900
50 40 H750N DS-471025 70 300 550
65 58 H764N DS-471027 - 140 280
80 90 H779N DS-471029 - 80 160
100 145 H7100N DS-471031 - - - 200
125 220 H7125N DS-471067 - - - 130
150 320 H7150N DS-471068 - - - 80
ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

202 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Flange valves PN 16
3-point
AC 230 V

Actuators

Valves / Actuators
Type DWH05-230 DWH10-230 DWH15-230 DWH25-230
Actuator Standard Art.-No. DS-472032 DS-472033 DS-472034 DS-472035

Positioning force 500 N 1000 N 1500 N 2500 N


Stroke 15 mm 20 mm 20 mm 40 mm
Run time 150 s 150 s 150 s 150 s
Emergency function - - - -
Run time emergency function - - - -
Control - - - -
Working range / Acknowledgement - - - -

Through valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H611N DS-471043 1300 1600 1600 -
15 1 H612N DS-471073 1300 1600 1600 -
15 1.6 H613N DS-471045 1300 1600 1600 -
15 2.5 H614N DS-471074 1300 1600 1600 -
15 4 H615N DS-471047 1300 1600 1600 -
20 6.3 H620N DS-471049 900 1600 1600 -
25 10 H625N DS-471051 500 1300 1600 -
32 16 H632N DS-471053 350 1000 1600 -
40 25 H640N DS-471055 150 500 900 -
50 40 H650N DS-471057 70 300 550 -
65 58 H664N DS-471059 - 140 280 -
80 90 H679N DS-471061 - 80 160 -
100 145 H6100N DS-471063 - - - 200
125 220 H6125S DS-471065 - - - 110
150 320 H6150S DS-471066 - - - 70

Three-way mixing valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA ps kPA ps kPA ps kPA
15 0.63 H711N DS-471011 1300 1600 1600
15 1 H712N DS-471075 1300 1600 1600
15 1.6 H713N DS-471013 1300 1600 1600
15 2.5 H714N DS-471076 1300 1600 1600
15 4 H715N DS-471015 1300 1600 1600
20 6.3 H720N DS-471017 900 1600 1600
25 10 H725N DS-471019 500 1300 1600
32 16 H732N DS-471021 350 1000 1600
40 25 H740N DS-471023 150 500 900
50 40 H750N DS-471025 70 300 550
65 58 H764N DS-471027 - 140 280
80 90 H779N DS-471029 - 80 160
100 145 H7100N DS-471031 - - - 200
125 220 H7125N DS-471067 - - - 130
150 320 H7150N DS-471068 - - - 80
ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. Closing force = Stopping force

C 2018 - Technical changes excepted. Pictured products similar. 203


Retrofit Valves and Actuators

Retrofit: Replacement, reconstruction, modernization

We offer a comprehensive range of actuators specifically for


retrofitting in existing installations.
With our smart, universal retrofit concepts, DEOS actuators
can be mounted in an easy way on a great number of series
of different manufacturers.

The retrofit actuators are equipped with a special bracket and


are suitable for motorizing valves of different manufacturers up
to 20 mm hub.

Please contact us for additional retrofit products for valves


with short stroke up to 5,5 mm hub or for valves up to 50 mm
hub.

A compatibility list of the valve series is available. Please call


us: +49 5971 91133-0.

constant 3-point
AC/DC 24 V AC/DC 24 V AC 230 V

Retrofit Actuator
up to 20 mm stroke
Type DWH10-24Y-RE DWH15-24Y-RE DWH10-24-RE DWH10-230-RE DWH15-230-RE
Retrofit Actuator Art.-No. DS-472039 DS-472040 DS-472036 DS-472037 DS-472038

Positioning force 1000 N 1500 N 1000 N 1000 N 1500 N


Stroke 20 mm 20 mm 20 mm 20 mm 20 mm
Run time 150 s 150 s 150 s 150 s 150 s
Terminals x x x x x
Control DC 0 .. 10 V DC 0 .. 10 V - - -
Working range / Acknowledgement DC 0,5 .. 10 V DC 0,5 .. 10 V - - -

1
start of availability of products on request

204 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Threaded valves - Red bronze PN 16
constant
AC/DC 24 V

NEU
Actuators NEW

Valves / Actuators
Type DWH10-24Y-CAN*
Actuator with CAN-Bus Interface Art.-No. DS-472046

Type DWH10-24Y-BAC
Actuator with BACnet Interface Art.-No. DS-472049

Positioning force 1000 N1


Stroke 20 mm
Run time 150 s
Emergency set time, spring pulling -
Emergency set time, spring pushing -
Control DC 0...10 V
Working range DC 2...10 V
Control / Acknowledgement Bus x

Through valve with outside thread, PN 16, RG5, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA


15 0.63 H411B DS-471033 1600
15 1 H412B DS-471034 1600
15 1.6 H413B DS-471035 1600
15 2.5 H414B DS-471036 1600
15 4 H415B DS-471037 1600
20 6.3 H420B DS-471038 1600
25 10 H425B DS-471039 1350
32 16 H432B DS-471040 1000
40 25 H440B DS-471041 500
50 40 H450B DS-471042 300

Three-way mixing valve with outside thread, PN 16, RG5, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA


15 0.63 H511B DS-471001 1600
15 1 H512B DS-471002 1600
15 1.6 H513B DS-471003 1600
15 2.5 H514B DS-471004 1600
15 4 H515B DS-471005 1600
20 6.3 H520B DS-471006 1600
25 10 H525B DS-471007 1350
32 16 H532B DS-471008 1000
40 25 H540B DS-471009 500
50 40 H550B DS-471010 300

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. 1
Closing force1000 N, Stopping force 800 N

C 2018 - Technical changes excepted. Pictured products similar. 205


Flange valves PN 6 Valves and Actuators
constant
AC/DC 24 V

NEU
Actuators NEW

Type DWH10-24Y-CAN*
Actuator with CAN-Bus Interface Art.-No. DS-472046

Type DWH10-24Y-BAC
Actuator with BACnet Interface Art.-No. DS-472049

Positioning force 1000 N1


Stroke 20 mm
Run time 150 s
Emergency set time, spring pulling -
Emergency set time, spring pushing -
Control DC 0...10 V
Working range DC 2...10 V
Control / Acknowledgement Bus x

Through valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA


15 0.63 H611R DS-471044 600
15 1 H612R DS-471070 600
15 1.6 H613R DS-471046 600
15 2.5 H614R DS-471071 600
15 4 H615R DS-471048 600
20 6.3 H620R DS-471050 600
25 10 H625R DS-471052 600
32 16 H632R DS-471054 600
40 25 H640R DS-471056 500
50 40 H650R DS-471058 300
65 58 H664R DS-471060 140
80 90 H679R DS-471062 80

Three-way mixing valve with flange fitting, PN 6, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA


15 0.63 H711R DS-471012 600
15 1 H712R DS-471072 600
15 1.6 H713R DS-471014 600
15 2.5 H714R DS-471069 600
15 4 H715R DS-471016 600
20 6.3 H720R DS-471018 600
25 10 H725R DS-471020 600
32 16 H732R DS-471022 600
40 25 H740R DS-471024 500
50 40 H750R DS-471026 300
65 58 H764R DS-471028 140
80 90 H779R DS-471030 80

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. 1
Closing force1000 N, Stopping force 800 N

206 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Flange valves PN 16
constant
AC/DC 24 V

NEU
Actuators NEW

Valves / Actuators
Type DWH10-24Y-CAN*
Actuator with CAN-Bus Interface Art.-No. DS-472046

Type DWH10-24Y-BAC
Actuator with BACnet Interface Art.-No. DS-472049

Positioning force 1000 N1


Stroke 20 mm
Run time 150 s
Emergency set time, spring pulling -
Emergency set time, spring pushing -
Control DC 0...10 V
Working range DC 2...10 V
Control / Acknowledgement Bus x

Through valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA


15 0.63 H611N DS-471043 1600
15 1 H612N DS-471073 1600
15 1.6 H613N DS-471045 1600
15 2.5 H614N DS-471074 1600
15 4 H615N DS-471047 1600
20 6.3 H620N DS-471049 1600
25 10 H625N DS-471051 1350
32 16 H632N DS-471053 1000
40 25 H640N DS-471055 500
50 40 H650N DS-471057 300
65 58 H664N DS-471059 140
80 90 H679N DS-471061 80

Three-way mixing valve with flange fitting, PN 16, GG25, 5...120 °C

DN kvs [m³/h] Type Art.-No. ps kPA


15 0.63 H711N DS-471011 1600
15 1 H712N DS-471075 1600
15 1.6 H713N DS-471013 1600
15 2.5 H714N DS-471076 1600
15 4 H715N DS-471015 1600
20 6.3 H720N DS-471017 1600
25 10 H725N DS-471019 1350
32 16 H732N DS-471021 1000
40 25 H740N DS-471023 500
50 40 H750N DS-471025 300
65 58 H764N DS-471027 140
80 90 H779N DS-471029 80

ps kPA = Closing pressure at which the actuator still ensures positive closing of the valve. 1
Closing force1000 N, Stopping force 800 N

C 2018 - Technical changes excepted. Pictured products similar. 207


Overview Control ball valves

constant control valves


control ball valves

2-way R20.. R4..

3-way R30.. R5..

Page 204-205 206-207

Connection
Inside thread x
Outside thread x

Temperature of medium
-10° .. +120°C x
+6°C .. 100°C x
-10°C...+5°C
x
with spindle heating

Application in buildings1
closed circuits x x

Allowed static pressure ps [kPA] 1600 1600


Differential pressure p [kPA] 1000 / 2002 200
Closing pressure ps [kPA] 1400 1400

DN kvs [m³/h]
15 0.63 R20.. / R30.. R4.. / R5..
15 1 R20.. / R30.. R4.. / R5..
15 1.6 R20.. / R30.. R4.. / R5..
15 2.5 R20.. / R30.. R4.. / R5..
15 4 R20.. / R30.. R4.. / R5..
15 6.3 R20.. -
20 4 R20.. / R30.. R4.. / R5..
20 6.3 R20.. / R30.. R4.. / R5..
20 8.6 R20.. R4..
25 6.3 R20.. / R30.. R4.. / R5..
25 10 R20.. / R30.. R4.. / R5..
25 16 R20.. R4..
32 16 R20.. / R30.. R4.. / R5..
40 16 R20.. / R30.. R4.. / R5..
40 25 R20.. R4..
50 25 R20.. / R30.. R4.. / R5..
50 40 R20.. R4..

1
available on request for applications in outdoor installations
2
for low noise operation

208 C 2018 - Technical changes excepted. Pictures similar.


Control ball valves Overview

Stop valves and switching valves


Ball valves

Valves / Actuators
2-way R20.. R4..

3-way R30.. R5..

Page 208 209

Connection
Inside thread x
Outside thread x
Flange

Temperature of medium
-10° .. +120°C
+6°C .. 100°C x x
-10°C .. + 5°C
x
with spindle heating

Application in buildings1
closed circuit x x

Allowed static pressure ps [kPA] 1600 1600


Differential pressure p [kPA] 1000 / 2002 400 / 2002
Closing pressur ps [kPA] 1400 1400

DN kvs [m³/h]
15 8.6 R20.. / R30.. R4.. / R5..
20 21 R20.. / R30.. R4.. / R5..
25 26 R20.. / R30.. R4.. / R5..
32 16 R20.. / R30.. R4.. / R5..
32 32 R20.. / R30.. R4..
40 32 R20.. / R30.. R4.. / R5..
50 49 R20.. / R30.. R4.. / R5..

1
available on request for applications in outdoor installations
2
for low noise operation

C 2018 - Technical changes excepted. Pictured products similar. 209


Control ball valve with female thread Control ball valves

bus compatible constant 3-point


AC/DC 24 V AC/DC 24 V AC/DC 24 V AC 230 V

Control ball valves

Type PWD05-24-CAN PWD10-24-CAN


with CAN-bus Interface Art.-No. DS-492002 DS-492003

Type PWD05-24-BAC PWD10-24-BAC


with BACnet® MS/TP Art.-No. DS-492000 DS-492001

Type PWD05-24Y PWD20-24Y PWD20-24 PWD20-230


Standard Art.-No. DS-492004 DS-492007 DS-492008 DS-492009

Torque 5 Nm 10 Nm 5 Nm 20 Nm 20 Nm 20 Nm
Run time 90 s 90 s 90 s 90 s 90 s 90 s
Control DC 0 .. 10 V x x x x - -
Working range DC 2 .. 10 V x x x x - -
Acknowledgement DC 2 .. 10 V - - x x - -
Working range/Acknowledgement bus x x - - - -

2-way Control ball valve

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 0.63 R2015-P63-S1 DS-494000 x x x x x x
15 1 R2015-1-S1 DS-494001 x x x x x x
15 1.6 R2015-1P6-S1 DS-494002 x x x x x x
15 2.5 R2015-2P5-S1 DS-494003 x x x x x x
15 4 R2015-4-S1 DS-494004 x x x x x x
15 6.3 R2015-6P3-S1 DS-494005 x x x x x x
20 4 R2020-4-S2 DS-494006 x x x x x x
20 6.3 R2020-6P3-S2 DS-494007 x x x x x x
20 8.6 R2020-8P6-S2 DS-494008 x x x x x x
25 6.3 R2025-6P3-S2 DS-494009 x x x x x x
25 10 R2025-10-S2 DS-494010 x x x x x x
25 16 R2025-16-S2 DS-494011 x x x x x x
32 16 R2032-16-S3 DS-494012 - x - x x x
40 16 R2040-16-S3 DS-494013 - x - x x x
40 25 R2040-25-S3 DS-494014 - x - x x x
50 25 R2050-25-S4 DS-494015 - - - x x x
50 40 R2050-40-S4 DS-494016 - - - x x x

210 C 2018 - Technical changes excepted. Pictures similar.


Control ball valves Control ball valve with female thread

bus compatible constant 3-point


AC/DC 24 V AC/DC 24 V AC/DC 24 V AC 230 V

Valves / Actuators
Control ball valves

Type PWD05-24-CAN PWD10-24-CAN


with CAN-bus Interface Art.-No. DS-492002 DS-492003

Type PWD05-24-BAC PWD10-24-BAC


with BACnet® MS/TP Art.-No. DS-492000 DS-492001

Type PWD05-24Y PWD20-24Y PWD20-24 PWD20-230


Standard Art.-No. DS-492004 DS-492007 DS-492008 DS-492009

Torque 5 Nm 10 Nm 5 Nm 20 Nm 20 Nm 20 Nm
Run time 90 s 90 s 90 s 90 s 90 s 90 s
Control DC 0 .. 10 V x x x x - -
Working range DC 2 .. 10 V x x x x - -
Acknowledgement DC 2 .. 10 V - - x x - -
Working range/Acknowledgement bus x x - - - -

3-way Control ball valve Flow Bypass B-AB approx. 70% of kvs

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 0.63 R3015-P63-S1 DS-494017 x x x x x x
15 1 R3015-1-S1 DS-494018 x x x x x x
15 1.6 R3015-1P6-S1 DS-494019 x x x x x x
15 2.5 R3015-2P5-S1 DS-494020 x x x x x x
15 4 R3015-4-S1 DS-494021 x x x x x x
20 4 R3020-4-S2 DS-494022 x x x x x x
20 6.3 R3020-6P3-S2 DS-494023 x x x x x x
25 6.3 R3025-6P3-S2 DS-494024 x x x x x x
25 10 R3025-10-S2 DS-494025 x x x x x x
32 16 R3032-16-S3 DS-494026 - x - x x x
40 16 R3040-16-S3 DS-494027 - x - x x x
50 25 R3050-25-S4 DS-494028 - - - x x x

C 2018 - Technical changes excepted. Pictured products similar. 211


Control ball valve with male thread Control ball valves

bus compatible constant 3-point


AC/DC 24 V AC/DC 24 V AC/DC 24 V AC 230 V

Control ball valves

Type PWD05-24-CAN PWD10-24-CAN


with CAN-bus Interface Art.-No. DS-492002 DS-492003

Type PWD05-24-BAC PWD10-24-BAC


with BACnet® MS/TP Art.-No. DS-492000 DS-492001

Type PWD05-24Y PWD20-24Y PWD20-24 PWD20-230


Standard Art.-No. DS-492004 DS-492007 DS-492008 DS-492009

Torque 5 Nm 10 Nm 5 Nm 20 Nm 20 Nm 20 Nm
Run time 90 s 90 s 90 s 90 s 90 s 90 s
Control DC 0 .. 10 V x x x x - -
Working range DC 2 .. 10 V x x x x - -
Acknowledgement DC 2 .. 10 V - - x x - -
Working range/Acknowledgement bus x x - - - -

2-way Control ball valve

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 0.63 R409 DS-493029 x x x x x x
15 1 R410 DS-493030 x x x x x x
15 1.6 R411 DS-493031 x x x x x x
15 2.5 R412 DS-493032 x x x x x x
15 4 R413 DS-493033 x x x x x x
15 6.3 R414 DS-493034 x x x x x x
20 4 R417 DS-493035 x x x x x x
20 6.3 R418 DS-493036 x x x x x x
20 8.6 R419 DS-493037 x x x x x x
25 6.3 R422 DS-493038 x x x x x x
25 10 R423 DS-493039 x x x x x x
25 16 R424 DS-493040 x x x x x x
32 16 R431 DS-493041 - x - x x x
40 16 R438 DS-493042 - x - x x x
40 25 R439 DS-493043 - x - x x x
50 25 R448 DS-493044 - x - x x x
50 40 R449 DS-493045 - x - x x x

212 C 2018 - Technical changes excepted. Pictures similar.


Control ball valves Control ball valve with male thread

bus compatible constant 3-point


AC/DC 24 V AC/DC 24 V AC/DC 24 V AC 230 V

Valves / Actuators
Control ball valves

Type PWD05-24-CAN PWD10-24-CAN


with CAN-bus Interface Art.-No. DS-492002 DS-492003

Type PWD05-24-BAC PWD10-24-BAC


with BACnet® MS/TP Art.-No. DS-492000 DS-492001

Type PWD05-24Y PWD20-24Y PWD20-24 PWD20-230


Standard Art.-No. DS-492004 DS-492007 DS-492008 DS-492009

Torque 5 Nm 10 Nm 5 Nm 20 Nm 20 Nm 20 Nm
Run time 90 s 90 s 90 s 90 s 90 s 90 s
Control DC 0 .. 10 V x x x x - -
Working range DC 2 .. 10 V x x x x - -
Acknowledgement DC 2 .. 10 V - - x x - -
Working range/Acknowledgement bus x x - - - -

3-way Control ball valve Flow Bypass B-AB approx. 70% of kvs

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 0.63 R509 DS-493046 x x x x x x
15 1 R510 DS-493047 x x x x x x
15 1.6 R511 DS-493048 x x x x x x
15 2.5 R512 DS-493049 x x x x x x
15 4 R513 DS-493050 x x x x x x
20 4 R517 DS-493051 x x x x x x
20 6.3 R518 DS-493052 x x x x x x
25 6.3 R522 DS-493053 x x x x x x
25 10 R523 DS-493054 x x x x x x
32 16 R531 DS-493055 - x - x x x
40 16 R538 DS-493056 - x - x x x
50 25 R548 DS-493057 - x - x x x

C 2018 - Technical changes excepted. Pictured products similar. 213


Open-Close / Switching ball valves with male thread

Open - close
AC/DC 24 V AC/DC 24 V AC 230 V AC 230 V

Ball valves

Type PWD05-24 PWD20-24 PWD05-230 PWD20-230


Standard Art.-No. DS-492005 DS-492008 DS-492006 DS-492009

Torque 5 Nm 20 Nm 5 Nm 20 Nm
Run time 90 s 90 s 90 s 90 s
Aux. switch adjustable - - - -
Control with close contact x x x x
Control with changeover contact x x x x

2-way Open-Close ball valves

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 15 R2015-S1 DS-494078 x x x x
20 32 R2020-S2 DS-494079 x x x x
25 26 R2025-S2 DS-494080 x x x x
32 18 R2032-B2 DS-494081 x x x x
32 32 R2032-S3 DS-494082 - x - x
40 31 R2040-S3 DS-494083 - x - x
50 49 R2050-S4 DS-494118 - x - x

3-way Open-Close ball valves Flow Bypass B-AB approx. 50% of kvs

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 15 R3015-S1 DS-494084 x x x x
20 32 R3020-S2 DS-494085 x x x x
25 26 R3025-S2 DS-494086 x x x x
32 18 R3032-B2 DS-494087 x x x x
32 32 R3032-S3 DS-494088 - x - x
40 31 R3040-S3 DS-494089 - x - x
50 49 R3050-S4 DS-494090 - x - x

214 C 2018 - Technical changes excepted. Pictures similar.


Open-Close / Switching ball valves with female thread

Open - close
AC/DC 24 V AC/DC 24 V AC 230 V AC 230 V

Valves / Actuators
Ball valves

Type PWD05-24 PWD20-24 PWD05-230 PWD20-230


Standard Art.-No. DS-492005 DS-492008 DS-492006 DS-492009

Torque 5 Nm 20 Nm 5 Nm 20 Nm
Run time 90 s 90 s 90 s 90 s
Aux. switch adjustable - - - -
Control with close contact x x x x
Control with changeover contact x x x x

2-way Open-Close ball valves

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 8.6 R415 DS-493091 x x x x
20 21 R420 DS-493092 x x x x
25 26 R425 DS-493093 x x x x
32 16 R430 DS-493094 x x x x
32 32 R432 DS-493095 - x - x
40 32 R440 DS-493096 - x - x
50 49 R450 DS-493097 - x - x

3-way Open-Close ball valves Flow Bypass B-AB approx. 50% of kvs

DN KVS Type Art.-No. possible combination


A-AB
[m³/h]
15 8.6 R515 DS-493098 x x x x
20 21 R520 DS-493099 x x x x
25 26 R525 DS-493100 x x x x
32 32 R532 DS-493101 - x - x
40 32 R540 DS-493102 - x - x
50 49 R550 DS-493103 - x - x

C 2018 - Technical changes excepted. Pictured products similar. 215


Control ball valve with female thread Control ball valves

bus compatible constant


AC/DC 24 V AC/DC 24 V

Actuators Control ball valves

Type PWD05-24-CAN PWD10-24-CAN


with CAN-bus Interface Art.-No. DS-492002 DS-492003

Type PWD05-24-BAC PWD10-24-BAC


with BACnet® MS/TP Art.-No. DS-492000 DS-492001

Type PWD05-24Y
Standard Art.-No. DS-492004

Torque 5 Nm 10 Nm 5 Nm
Run time 90 s 90 s 90 s
Control DC 0 .. 10 V x x x
Working range DC 2 .. 10 V x x x
Acknowledgement DC 2 .. 10 V - - x
Working range/Acknowledgement bus x x -

6-way Control ball valve, DN15, outside thread Rp 1/2“

DN KVS A-AB Type Art.-No. possible combination


[m³/h]

15 0.25 / 0.25 R3015-P25-P25-B2 DS-495001 x x x


15 0.25 / 0.4 R3015-P25-P4-B2 DS-495002 x x x
15 0.25 / 0.63 R3015-P25-P63-B2 DS-495003 x x x
15 0.25 / 1.0 R3015-P25-1-B2 DS-495004 x x x
15 0.25 / 1.3 R3015-P25-1P3-B2 DS-495005 x x x
15 0.4 / 0.25 R3015-P4-P25-B2 DS-495006 x x x
15 0.4 / 0.4 R3015-P4-P4-B2 DS-495007 x x x
15 0.4 / 0.63 R3015-P4-P63-B2 DS-495008 x x x
15 0.4 / 1.0 R3015-P4-1-B2 DS-495009
15 0.4 / 1.3 R3015-P4-1P3-B2 DS-495010
15 0.63 / 0.25 R3015-P63-P25-B2 DS-495011 x x x
15 0.63 / 0.4 R3015-P63-P4-B2 DS-495012 x x x
15 0.63 / 0.63 R3015-P63-P63-B2 DS-495013 x x x
15 0.63 / 1.0 R3015-P63-1-B2 DS-495014
15 0.63 / 1.3 R3015-P63-1P3-B2 DS-495015
15 1.0 / 0.25 R3015-1-P25-B2 DS-495016 - x -
15 1.0 / 0.4 R3015-1-P4-B2 DS-495017
15 1.0 / 0.63 R3015-1-P63-B2 DS-495018
15 1.0 / 1.0 R3015-1-1-B2 DS-495019
15 1.0 / 1.3 R3015-1-1P3-B2 DS-495020
15 1.3 / 0.25 R3015-1P3-P25-B2 DS-495021 - x -
15 1.3 / 0.4 R3015-1P3-P4-B2 DS-495022 - x -
15 1.3 / 0.63 R3015-1P3-P63-B2 DS-495023
15 1.3 / 1.0 R3015-1P3-1-B2 DS-495024
15 1.3 / 1.3 R3015-1P3-1P3-B2 DS-495025

216 C 2018 - Technical changes excepted. Pictures similar.


Control ball valves Control ball valve with female thread

bus compatible constant


AC/DC 24 V AC/DC 24 V

Valves / Actuators
Actuators Control ball valves

Type PWD05-24-CAN PWD10-24-CAN


with CAN-bus Interface Art.-No. DS-492002 DS-492003

Type PWD05-24-BAC PWD10-24-BAC


with BACnet® MS/TP Art.-No. DS-492000 DS-492001

Type PWD05-24Y
Standard Art.-No. DS-492004

Torque 5 Nm 10 Nm 5 Nm
Run time 90 s 90 s 90 s
Control DC 0 .. 10 V x x x
Working range DC 2 .. 10 V x x x
Acknowledgement DC 2 .. 10 V - - x
Working range/Acknowledgement bus x x -

6-way Control ball valve, DN20, outside thread Rp 3/4“

DN KVS A-AB Type Art.-No. possible combination


[m³/h]

20 0.63 / 1.6 R3020-P63-1P6-B2 DS-495026 x x x


20 0.63 / 2.5 R3020-P63-2P5-B2 DS-495027 x x x
20 1.0 / 1.6 R3020-1-1P6-B2 DS-495028 x x x
20 1.0 / 2.5 R3020-1-2P5-B2 DS-495029 x x x
20 1.6 / 0.63 R3020-1P6-P63-B2 DS-495030 x x x
20 1.6 / 1.0 R3020-1P6-1-B2 DS-495031 x x x
20 1.6 / 1.6 R3020-1P6-1P6-B2 DS-495032 x x x
20 1.6 / 2.5 R3020-1P6-2P5-B2 DS-495033 x x x
20 2.5 / 0.63 R3020-2P5-P63-B2 DS-495034 x x x
20 2.5 / 1.0 R3020-2P5-1-B2 DS-495035 x x x
20 2.5 / 1.6 R3020-2P5-1P6-B2 DS-495036 x x x
20 2.5 / 2.5 R3020-2P5-2P5-B2 DS-495037 x x x

C 2018 - Technical changes excepted. Pictured products similar. 217


Pipe screw fittings Valves and Actuators

Article Type Art.-No.

Pipe screw fittings, cast iron, zinc-plated


preferably for vertical valves H4..B and H5..B
Scope of delivery 1 union nut (G-thread)
ZH45.. 1 insert (Rp-thread)
1 flat seal (IT)
DN [mm] G Rp
15 G 1 1/8“ 1/2“ ZH4515 DS-473007
20 G 1 1/4“ 3/4“ ZH4520 DS-473008
25 G 1 1/2“ 1“ ZH4525 DS-473009
32 G 2“ 1 1/4“ ZH4532 DS-473010
40 G 2 1/4“ 1 1/2“ ZH4540 DS-473011
50 G 1 3/4“ 2“ ZH4550 DS-473012
Pipe screw fittings, brass nickelplated
preferably for control ball valves with outside thread R4..
and R5..
Scope of delivery 1 union nut (G-thread
ZR45.. 1 insert (Rp-thread)
1 flat seal (IT)
DN [mm] G Rp
15 G 1“ 1/2“ ZR4515 DS-491424
20 G 1 1/4“ 3/4“ ZR4520 DS-491425
25 G 1 1/2“ 1“ ZR4525 DS-491426
32 G 2“ 1 1/4“ ZR4532 DS-491427
40 G 2 1/4“ 1 1/2“ ZR4540 DS-491428
50 G 1 3/4“ 2“ ZR4550 DS-491429
Pipe screw fittings, brass nickelplated
preferably for control ball valves with inside thread R2..
und R3..
Scope of delivery 1 screwed socket (R-thread)
ZR23.. 1 union nut (G-thread)
1 insert (Rp-thread)
1 flat seal (IT)
DN [mm] Rp
15 1/2“ ZR2315 DS-491430
20 3/4“ ZR2320 DS-491431
25 1“ ZR2325 DS-491432
32 1 1/4“ ZR2332 DS-491433
40 1 1/2“ ZR2340 DS-491434
50 2“ ZR2350 DS-491435

Notes:
For H4..B and H5..B series actuators black screw fittings type ZR45 may also be used.
Exception: valves DN15; here only zinc-plated screw fittings ZH4515 are permitted
Always check for the compatibility of red bronze, copper and zinc.

218 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Zone Valves
3-point constant
AC 230 V AC/DC 24 V

Zone actuators

Valves / Actuators
Type CQ230A CQ24A CQ24A-SR CQK24A-SR
Zone actuators Art.-No. DS-475055 DS-475052 DS-475053 DS-475054

Torque 1 Nm 1 Nm 1 Nm 1 Nm
Run time 75 s 75 s 75 s 75 s ??
Emergency function - - - x
Run time emergency function - - - -
Control - - DC 0 .. 10 V DC 0 .. 10 V
Working range / feedback - - - -

2-way control ball valve, female thread, PN 16, +2 ... +90 °C

DN kvs [m³/h] Type Art.-No. possible combination


15 0.4 - 4.8 C215Q-J DS-494119 x x x x
20 0.5 - 8 C220Q-K DS-494120 x x x x

3-way control ball valve, female thread, PN 16, +2 ... +90 °C

DN kvs [m³/h] Type Art.-No. possible combination


15 2.5 C315Q-H DS-494121 x x x -
20 4.0 C320Q-J DS-494122 x x x -

Tube fittings

DN Zoll Type Art.-No.


15 1/2“ ZR2315 DS-491430
20 3/4“ ZR2320 DS-491431

C 2018 - Technical changes excepted. Pictured products similar. 219


Thermoelectrical actuators Valves and Actuators

Article Type Art.-No.


Thermoelectrical actuator -normally close to (NC)- for driving DS-AST 20405-00-373-01 DS-475043
valves on heating circuit distributors, radiators, convectors,
etc.

• Adjustment control
• First-Open Function
• Function display
• Plug-in assembly
• 100% Protection against leaky valves
• Removal security with removable SaveGuard (visor)
• Guaranteed overload protection

7 mm
Operation voltage: 230 V, 50/60 Hz
Operation power: 1,8 W

52,1 mm

50,4 mm
Activation current: < 550 mA for max. 100 ms
Degree of protection: IP 54
Protection class: II
Stroke: 4 mm 58,4 mm 44,4 mm

Actuating force: 100 N +/- 5%


Cable (plug-in connector): 2 x 0,75 mm²,
Line length: 1000 mm
Housing color: white RAL 9003
Dimensions: 50,4+7 / 44,4 / 58,4 mm

Delivery: without valve adapter1

Thermoelectrical actuator -normally close to (NC)- for driving DS-AST 40405-00-373-01 DS-475044
valves on heating circuit distributors, radiators, convectors,
etc.

• Adjustment control
• First-Open Function
• Functional display
• Plug- in assembly
• 100% Protection against leaky valves
• Removal security with removable SaveGuard (visor)
• Guaranteed overload protection
7 mm

Operating voltage: 24 AC / DC,


+20% till -10%, 0-60 Hz
52,1 mm

50,4 mm

Operating power: 1,8 W


Activation current: max. 300 mA
Degree of protection: IP 54
Stroke: 4 mm 58,4 mm 44,4 mm

Actuating force: 100 N +/- 5%


Cable (plug-in connector): 2 x 0,75 mm²
Line length: 1000 mm
Housing color: white RAL 9003:
Dimensions 50,4+7 / 44,4 / 58,4 mm

Delivery: without valve adapter1

Caution: When using serveral actuators take care of the power supply units capacity.
1
Caution: You will need a valve adapter for mounting. Please order the suitable adapter for your valve.
You will find an overview of the valve adapters on page 222-223
220 C 2018 - Technical changes excepted. Pictures similar.
Valves and Actuators Thermoelectrical actuators

Article Type Art.-No.


Thermoelectrical actuator -normally close to (NC)- for driving DS-APR 40405-00-373-01 DS-475042
valves on heating circuit distributors, radiators, convectors,

Valves / Actuators
etc.

Adjustment control
First-Open Function
Function display
Plug-in assembly
100% Protection against leaky valves
Proportional actuating travel
Self-calibrating

7 mm
Closing point detection

Operating voltage: 24 V AC, 50/60 Hz

51,1 mm
53 mm
+20% till -10%, 50/60 Hz
Control voltage input: 0-10 V DC
Input resistance: 100 kOhm
Operating power: 2,0 W 61,5 mm 44,3 mm

Degree of protection: IP 54
Stroke: 4 mm
Actuating force: 100 N +/- 5%
Activation current max.: <320 mA for max. 2 min.
Average actuating speed: 30 s/mm
Cable (plug-in connector): 3 x 0,22 mm²
Line length: 1000 mm
Housing color: white RAL 9003
Dimensions: 51,1+7 / 44,3 / 61,6 mm
Delivery: without valve adapter1

Thermoelectrical actuator -normally close to (NC)- for driving DS-APR 42405-00-373-01 DS-475041
valves on heating circuit distributors, radiators, convectors,
etc.

Adjustment control
First-Open Function
Function display
Plug-in assembly
100% Protection against leaky valves
Proportional actuating travel
Self-calibrating
7 mm

Closing point detection

Operating voltage: 24 V DC
Control voltage input: 0-10 V DC
51,1 mm
53 mm

Input resistance: 100 kOhm


Operation power: 2,0 W
Degree of protection: IP 54
61,5 mm 44,3 mm
Stroke: 4 mm
Actuating force: 100 N +/- 5%
Activation current max.: <320 mA for max. 2 min.
Average actuating speed: 30 s/mm
Cable (plug-in connector): 3 x 0,22 mm²
Line length: 1000 mm
Housing color: white RAL 9003
Dimensions: 51,1+7 / 44,3 / 61,6 mm
Delivery: without valve adapter1

Caution: When using serveral actuators take care of the power supply units capacity.
1
Caution: You will need a valve adapter for mounting. Please order the suitable adapter for your valve.
You will find an overview of the valve adapters on page 222-223
C 2018 - Technical changes excepted. Pictured products similar. 221
Thermoelectrical actuators Valves and Actuators

Overview valve adapter for thermoelectrical actuators DS-ASTx and APRx


The valve adapter assortment guarantees a perfect match of the actuator to almost all valve bottoms and heating circuit distribu-
tors available on the market. The Actuator is simply plugged on to the valve adapter previously installed manually.

Screw the valve adapter Connect the line to the Position the OEM Actuator Latch the OEM Actuator
manually onto the valve. actuator. manually in vertical position 5 to the valve adapter by
to the valve adapter. manually applied vertical
pressure until a clicking
sound is heard.

Article Type Art.-No.


Beulco (vor 2005) VA 04 H DS-VA04H DS-475010
Beulco (nach 2005) VA 10 DS-VA10 DS-475011
Böhnisch SBK (ab 1998) VA 80 DS-VA80 DS-475012
Cazzaniga VA 50 DS-VA50 DS-475013
Comap VA 70 H DS-VA70H DS-475014
Danfoss RA VA78 DS-VA78 DS-475015
Danfoss RA V / L VA 59 DS-VA59 DS-475016
Danfoss RAV VA 72 DS-VA72 DS-475017
Dumser VA 10 DS-VA10 DS-475011
Giacomini VA 26 DS-VA26 DS-475018
Giacomini Eckventil VA 26 H DS-VA26H DS-475019
Heimeier VA 80 DS-VA80 DS-475012
Herz VA 16 DS-VA16 DS-475020
Honeywell & Braukmann VA 50 DS-VA50 DS-475013
IVAR VA 80 DS-VA80 DS-475012
Kermi (Kompaktheizkörper) VA 81 H DS-VA81H DS-475021
MMA VA 54 DS-VA54 DS-475022
MNG (ab 1998) VA 80 DS-VA80 DS-475012
Onda VA 80 DS-VA80 DS-475012
Oventrop (bis 1997) VA 39 DS-VA39 DS-475023
Oventrop (ab 1997) VA 80 DS-VA80 DS-475012
spezielle Ventile auch VA 10 DS-VA10 DS-475011
Polytherm VA 16 H DS-VA16H DS-475024
Reich (Verteiler) VA 50 DS-VA50 DS-475013

222 C 2018 - Technical changes excepted. Pictures similar.


Valves and Actuators Thermoelectrical actuators

Overview valve adapter for thermoelectrical actuators DS-ASTx and APRx

Valves / Actuators
Article Type Art.-No.
Rotex VA 94 DS-VA94 DS-475025
Schlösser (bis 1993) VA 20 H DS-VA20H DS-475026
Schlösser (ab 1993) VA 80 DS-VA80 DS-475012
Siemens VA 80 DS-VA80 DS-475012
spezielle Ventile auch VA 10 DS-VA10 DS-475011
Strawa (ab2003) VA 80 DS-VA80 DS-475012
Taco VA 80 DS-VA80 DS-475012
Temset VA 97 DS-VA97 DS-475027
Thermotechnik Edelstahl VA 91 DS-VA91 DS-475028
Tour & Anderson (M28) VA 32 DS-VA32 DS-475029
Tour & Anderson (M30) VA 80 DS-VA80 DS-475012
Universa (vor 1999) VA 70 H DS-VA70H DS-475030
Universa (ab 1999) VA 62 H DS-VA62H DS-475031
Velta VA 02 DS-VA02 DS-475032
Viega Messing VA 20 H DS-VA20H DS-475026
Viega Edelstahl VA 10 DS-VA10 DS-475011

Protective cover DS-AA SK 1004 DS-475049


Protective cover to prevent theft and vandalism for use with
thermoelectrical actuators:

• DS-AST 20405-00-373-01
• DS-AST 40405-00-373-01
• DS-APR 40405-00-373-01
• DS-APR 42405-00-373-01

Note:
To use the protective cover you need different valve
adapters. In case of need, please do not hesitate
to contact us.

C 2018 - Technical changes excepted. Pictured products similar. 223


PLDx Damper actuators

bus compatible constant


AC/DC 24 V AC/DC 24 V AC 230 V

Damper actuators

Type PLD10-24-CAN PLD20-24-CAN


with CAN-bus Interface Art.-No. DS-480020 DS-480021

Type PLD10-24-BAC PLD20-24-BAC


with BACnet® MS/TP Art.-No. DS-480018 DS-480019

Type PLD5-24Y PLD10-24Y PLD20-24Y PLD40-24Y PLD20-230Y


Standard Art.-No. DS-480002 DS-480005 DS-480008 DS-480012 DS-480009

Torque 10 Nm 20 Nm 5 Nm 10 Nm 20 Nm 40 Nm 20 Nm
Universal terminal block
8-26,7 mm 10-20 mm 6-20 mm 8-26,7 mm 10-20 mm 12-26,7 mm 10-20 mm
for axles
For flaps1 up to approx. 2 m² 4 m² 1 m² 2 m² 4 m² 8 m² 4 m²
Direction of rotation reversible (right / left) x x x x x x x
Run time motor 150 s 150 s 150 s 150 s 150 s 150 s 150 s
Run time spring - - - - - - -
Control DC 0 .. 10 V x x x x x x x
Working range DC 2 .. 10 V x x x x x x x
Acknowledgement DC 2 .. 10 V - - x x x x x
Working range/Acknowledgement bus x x - - - - -

1
normally shutting, essential is the certificate of origin

224 C 2018 - Technical changes excepted. Pictures similar.


Damper actuators PLDx

Open - close (3-point)


AC/DC 24 V

Valves / Actuators
Damper actuators

Type PLD5-24 PLD10-24 PLD20-24 PLD40-24


Standard Art.-No. DS-480000 DS-480003 DS-480006 DS-480010

Torque 5 Nm 10 Nm 20 Nm 40 Nm
Universal terminal block
8-20 mm 8-26,7 mm 10-20 mm 12-26,7 mm
for axles
For flaps1 up to approx. 1 m² 2 m² 4 m² 8 m²
Direction of rotation reversible (right / left) x x x x
Run time motor 150 s 150 s 150 s 150 s
Run time spring - - - -
Control with close contact x x x x
Control with changeover contact x x x x

Open - close (3-point)


AC 230 V

Damper actuators

Type PLD5-230 PLD10-230 PLD20-230 PLD40-230


Standard Art.-No. DS-480001 DS-480004 DS-480007 DS-480011

Torque 5 Nm 10 Nm 20 Nm 40 Nm
Universal terminal block
6-20 mm 8-26,7 mm 10-20 mm 12-26,7 mm
for axles
For flaps1 up to approx. 1 m² 2 m² 4 m² 8 m²
Direction of rotation reversible (right / left) x x x x
Run time motor 150 s 150 s 150 s 150 s
Run time spring - - - -
Control with close contact x x x x
Control with changeover contact x x x x

1
normally shutting, essential is the certificate of origin

C 2018 - Technical changes excepted. Pictured products similar. 225


PLDx with spring return Damper actuators

constant
AC/DC 24 V

Damper actuators

Type PLD10-24Y-FR PLD20-24Y-FR


Standard with spring return Art.-No. DS-480023 DS-480024

Torque 10 Nm 20 Nm
Universal terminal block
10-25,4 mm 10-25,4 mm
for axles
For flaps1 up to approx 2 m² 4 m²
Direction of rotation reversible (right / left) x x
Run time motor < 150 s < 150 s
Run time spring < 20 s < 20 s
Control DC 0 .. 10 V x x
Working range DC 2 .. 10 V x x
Acknowledgement DC 2 .. 10 V x x

Open - close
AC/DC 24 V

Damper actuators

Type PLD10-24-S2-FR PLD20-24-S2-FR


Standard with spring return Art.-No. DS-480025 DS-480026

Torque 10 Nm 20 Nm
Universal terminal block
10-25,4 mm 10-25,4 mm
for axles
For flaps1 up to approx 2 m² 4 m²
Direction of rotation reversible (right / left) x x
Run time motor < 150 s < 150 s
Run time spring < 20 s < 20 s
Control with close contact x x
integrated auxiliary switch, 2 x EPU x x

1
normally shutting, essential is the certificate of origin

226 C 2018 - Technical changes excepted. Pictures similar.


Actuators Accessories

Article Type Art.-No.


Potentiometer 10000 Ohm DS-P10000A-GR DS-480015

Valves / Actuators
for damper actuator
DS-PLD5-x, DS-PLD10-x, DS-PLD20-x and DS-PLD40-x

for throttling flaps


SR24A-5, GR24A-5, DR24A-7,
SR230A-5, GR230A-5 and DR230A-7

2-pole changeover switch DS-S2A-GR DS-480017

for damper actuators


DS-PLD5-x, DS-PLD10-x, DS-PLD20-x and DS-PLD40-x

for throttling flaps


SR24A-5, GR24A-5, DR24A-7,
SR230A-5, GR230A-5 and DR230A-7

Switching point adjustable across the whole turning range


0...1 for the air flap drive. Presetting possible using a
graduated scale.
2-pole changeover switch DS-S2A-F DS-480028

for damper actuators with spring return


DS-PLD10-x-FR und DS-PLD20-x-Fr

Switching point adjustable across the whole turning range


0...1 for the air flap drive. Presetting possible using a
graduated scale.
2-pole changeover switch DS-S2A-H DS-473022

for actuators DS-DWHx

Switching point adjustable across the whole turning range


0...1 for the air flap drive. Presetting possible using a
graduated scale.

C 2018 - Technical changes excepted. Pictured products similar. 227


2-way flange Throttling valves

Open - close (3-point)


AC/DC 24 V

Type of drive SR24A-5 GR24A-5 DR24A-5 DR24A-7


Torque 20 Nm 40 Nm max. 90Nm max. 90 Nm
Run time motor 90 s 150 s 150 s 150 s
Control 2-wire (with changeover contact) x x - -
Conrol 1-wire (with close contact) x x x x
Manual adjustment x x x x

2-way flange PN 6/10/16


Media temperature -20 °C ... 120 °C
- for water plus clycol concentration to max. 50% vol
D6..N

DN KVS Type Art.-No. ps ps ps ps


A-AB kPA kPA kPA kPA
[m³/h]
25 45 D625N DS-540041 1200 - - -
32 55 D632N DS-540042 1200 - - -
40 70 D640N DS-540043 1200 - - -
50 90 D650N DS-540044 1200 - - -
65 180 D665N DS-540045 1200 - - -
80 300 D680N DS-540046 1200 - -
100 580 D6100N DS-540049 - 1200 -
125 820 D6125N DS-540093 - - 1200

228 C 2018 - Technical changes excepted. Pictures similar.


Throttling valves 2-way flange

Open - close (3-point)


AC 230 V

Valves / Actuators
Type of drive SR230A-5 GR230A-5 DR230A-5 DR230A-7
Torque 20 Nm 40 Nm max. 90 Nm max. 90 Nm
Run time motor 90 s 150 s 150 s 150 s
Control 2-wire (with changeover contact) x x - -
Conrol 1-wire (with close contact) x x x x
Manual adjustment x x x x

2-way flange PN 6/10/16


Media temperature -20 °C ... 120 °C
- for water plus clycol concentration to max. 50% vol
D6..N

DN KVS Type Art.-No. ps ps ps


A-AB kPA kPA kPA
[m³/h]
25 45 D625N DS-540053 1200 - - -
32 55 D632N DS-540054 1200 - - -
40 70 D640N DS-540055 1200 - - -
50 90 D650N DS-540056 1200 - - -
65 180 D665N DS-540057 1200 - - -
80 300 D680N DS-540130 - 1200 - -
100 580 D6100N DS-540134 - - 1200 -
125 820 D6125N DS-540096 - - - 1200

C 2018 - Technical changes excepted. Pictured products similar. 229


2-way flange Throttling valves

Open - close (3-point)


AC 24 .. 240 V / DC 24 .. 125 V AC 230 V

Type of drive PRCA-S2-T SY6-230-3-T


Torque 160 Nm 650 Nm
Run time motor 35 s 38 s
adjustable 30 .. 120 s
Control 2-wire (with changeover contact) x x
Conrol 1-wire (with close contact) x -
Aux. switch 2 2
Aux. switches adjustable 1x 0 ..10° 2 x 3 .. 87 %
1x 0 .. 90°
Manual adjustment x x

2-way flange PN 6/10/16


Media temperature -20 °C ... 120 °C
- for water plus clycol concentration to max. 50% vol
D6..N D6..W

DN KVS Type Art.-No. ps kPA ps kPA


A-AB
[m³/h]
150 1600 D6150N DS-540135 1200 -
200 2900 D6200W DS-540136 1400 -
250 4400 D6250W DS-540137 1400 -
300 7300 D6300W DS-540138 800 -
350 10900 D6350N DS-540139 - 600

230 C 2018 - Technical changes excepted. Pictures similar.


Variable Speed Drive
Variable Speed Drive
Variable Speed Drive Page
up to 3,0 KW 227
up to 11,0 KW 228
up to 30,0 KW 229
up to 75,0 KW 230
up to 90,0 KW 231
Accessories 231

C 2018 - Technical changes excepted. Pictured products similar. 231


Variable Speed Drive Danfoss

Static variable speed drive


Static variable speed drive VLT® HVAC Drive FC-102 with user-optimized characteristic curve of moment

• 380/400/415/440/480 V, 50/60 Hz with or without graphics control unit.

• with integrated MODBUS RTU interface

• with radio signal suppressor acc. to EN 55011 Class A1/A2, product standard EN 61800-3 C2/C3 at up to max. 150 m
cable for motor and max. 50 m acc. to EN 55011 Class B, product standard EN 61800-3 C1 unrestricted use.

• Efficiency incl. filter and integrated net throttle 98 %.

Typ IP55 Control unit


numeric
display

VSD case VSD case


1.1 - 4.0 kW 5.5 - 7.5 kW

Type IP20 Control unit


graphic display

VSD case
from 1,1 kW for
control cabinet

VSD with integrated


mains isolations switch

232 C 2018 - Technical changes excepted. Pictures similar.


Danfoss Variable Speed Drive

Effective max. motor IP Control unit Type / Order-Code Art.-No.


output cont. current
KW A (at 400 V)

w/o FC-102P1K1T4 E20 H1 X X ST DS-131B7526


20 numerics FC-102P1K1T4 E20 H1 X N ST DS-131B5583
graphics FC-102P1K1T4 E20 H1 X G ST DS-131B4207
numerics FC-102P1K1T4 E55 H1 X N ST DS-131U3974
1,1 3,0
graphics FC-102P1K1T4 E55 H1 X G ST DS-131U0978
55 with integrated mains isolations switch

numerics FC-102P1K1T4 E55 H1 X N X1 ST DS-131U3992


graphics FC-102P1K1T4 E55 H1 X G X1 ST DS-131U2239

Variable Speed Drive


w/o FC-102P1K5T4 E20 H1 X X ST DS-131B7529
20 numerics FC-102P1K5T4 E20 H1 X N ST DS-131B5586
graphics FC-102P1K5T4 E20 H1 X G ST DS-131B4217
numerics FC-102P1K5T4 E55 H1 X N ST DS-131U3975
1,5 4,1
graphics FC-102P1K5T4 E55 H1 X G ST DS-131U0979
55 with integrated mains isolations switch

numerics FC-102P1K5T4 E55 H1 X N X1 ST DS-131U3991


graphics FC-102P1K5T4 E55 H1 X G X1 ST DS-131U2240
w/o FC-102P2K2T4 E20 H1 X X ST DS-131B7275
20 numerics FC-102P2K2T4 E20 H1 X N ST DS-131B5587
graphics FC-102P2K2T4 E20 H1 X G ST DS-131B4218

numerics FC-102P2K2T4 E55 H1 X N ST DS-131U3976


2,2 5,6
graphics FC-102P2K2T4 E55 H1 X G ST DS-131U0980
55 with integrated mains isolations switch

numerics FC-102P2K2T4 E55 H1 X N X1 ST DS-131U3990


graphics FC-102P2K2T4 E55 H1 X G X1 ST DS-131U2241
w/o FC-102P3K0T4 E20 H1 X X ST DS-131B7532
20 numerics FC-102P3K0T4 E20 H1 X N ST DS-131B5590
graphics FC-102P3K0T4 E20 H1 X G ST DS-131B4219
numerics FC-102P3K0T4 E55 H1 X N ST DS-131U3977
3,0 7,2
graphics FC-102P3K0T4 E55 H1 X G ST DS-131U0981
55 with integrated mains isolations switch

numerics FC-102P3K0T4 E55 H1 X N X1 ST DS-131U3989


graphics FC-102P3K0T4 E55 H1 X G X1 ST DS-131U2242

C 2018 - Technical changes excepted. Pictured products similar. 233


Variable Speed Drive Danfoss

Effective max. motor IP Control unit Type / Order-Code Art.-No.


output cont. current
KW A (at 400 V)

w/o FC-102P4K0T4 E20 H1 X X ST DS-131B7535


20 numerics FC-102P4K0T4 E20 H1 X N ST DS-131B5591
graphics FC-102P4K0T4 E20 H1 X G ST DS-131B3489
numerics FC-102P4K0T4 E55 H1 X N ST DS-131U3978
4,0 10,0
graphics FC-102P4K0T4 E55 H1 X G ST DS-131U0982
55 with integrated mains isolations switch

numerics FC-102P4K0T4 E55 H1 X N X1 ST DS-131U3988


graphics FC-102P4K0T4 E55 H1 X G X1 ST DS-131N5656
w/o FC-102P5K5T4 E20 H1 X X ST DS-131B7537
20 numerics FC-102P5K5T4 E20 H1 X N ST DS-131B5594
graphics FC-102P5K5T4 E20 H1 X G ST DS-131B4220

numerics FC-102P5K5T4 E55 H1 X N ST DS-131B6772


5,5 13,0
graphics FC-102P5K5T4 E55 H1 X G ST DS-131B4224
55 with integrated mains isolations switch

numerics FC-102P5K5T4 E55 H1 X N X1 ST DS-131B7544


graphics FC-102P5K5T4 E55 H1 X G X1 ST DS-131B7545
w/o FC-102P7K5T4 E20 H1 X X ST DS-131B7546
20 numerics FC-102P7K5T4 E20 H1 X N ST DS-131B5595
graphics FC-102P7K5T4 E20 H1 X G ST DS-131B3603
numerics FC-102P7K5T4 E55 H1 X N ST DS-131B6773
7,5 16,0
graphics FC-102P7K5T4 E55 H1 X G ST DS-131B4225
55 with integrated mains isolations switch

numerics FC-102P7K5T4 E55 H1 X N X1 ST DS-131B7547


graphics FC-102P7K5T4 E55 H1 X G X1 ST DS-131B7548
w/o FC-102P11KT4 E20 H1 X X ST DS-131F8649
20 numerics FC-102P11KT4 E20 H1 X N ST DS-131F8319
graphics FC-102P11KT4 E20 H1 X G ST DS-131F0427
numerics FC-102P11KT4 E55 H1 X N ST DS-131B6765
11,0 24,0
graphics FC-102P11KT4 E55 H1 X G ST DS-131B1277
55 with integrated mains isolations switch

numerics FC-102P11KT4 E55 H1 X N X1 ST DS-131B7550


graphics FC-102P11KT4 E55 H1 X G X1 ST DS-131B3607

234 C 2018 - Technical changes excepted. Pictures similar.


Danfoss Variable Speed Drive

Effective max. motor IP Control unit Type / Order-Code Art.-No.


output cont. current
KW A (at 400 V)

w/o FC-102P15KT4 E20 H1 X X ST DS-131F7659


20 numerics FC-102P15KT4 E20 H1 X N ST DS-131B8321
graphics FC-102P15KT4 E20 H1 X G ST DS-131F6631

numerics FC-102P15KT4 E55 H1 X N ST DS-131B7062


15,0 32,0
graphics FC-102P15KT4 E55 H1 X G ST DS-131B6126
55 with integrated mains isolations switch

numerics FC-102P15KT4 E55 H1 X N X1 ST DS-131B7587


graphics FC-102P15KT4 E55 H1 X G X1 ST DS-131B7588

Variable Speed Drive


w/o FC-102P18KT4 E20 H1 X X ST DS-131F8652
20 numerics FC-102P18KT4 E20 H1 X N ST DS-131F8322
graphics FC-102P18KT4 E20 H1 X G ST DS-131F6632
numerics FC-102P18KT4 E55 H1 X N ST DS-131B6766
18,5 37,5
graphics FC-102P18KT4 E55 H1 X G ST DS-131B3449
55 with integrated mains isolations switch

numerics FC-102P18KT4 E55 H1 X N X1 ST DS-131B7590


graphics FC-102P18KT4 E55 H1 X G X1 ST DS-131B9551
w/o FC-102P22KT4 E20 H1 X X ST DS-131F9917
20 numerics FC-102P22KT4 E20 H1 X N ST DS-131F9918
graphics FC-102P22KT4 E20 H1 X G ST DS-131F6629
numerics FC-102P22KT4 E55 H1 X N ST DS-131B6768
22,0 44,0
graphics FC-102P22KT4 E55 H1 X G ST DS-131B4267
55 with integrated mains isolations switch

numerics FC-102P22KT4 E55 H1 X N X1 ST DS-131B7593


graphics FC-102P22KT4 E55 H1 X G X1 ST DS-131B6292
w/o FC-102P30KT4 E20 H1 X X ST DS-131F9922
20 numerics FC-102P30KT4 E20 H1 X N ST DS-131F9923
graphics FC-102P30KT4 E20 H1 X G ST DS-131B5945
numerics FC-102P30KT4 E55 H1 X N ST DS-131B6769
30,0 61,0
graphics FC-102P30KT4 E55 H1 X G ST DS-131B4268
55 with integrated mains isolations switch

numerics FC-102P30KT4 E55 H1 X N X1 ST DS-131B7595


graphics FC-102P30KT4 E55 H1 X G X1 ST DS-131B5162

C 2018 - Technical changes excepted. Pictured products similar. 235


Variable Speed Drive Danfoss

Effective max. motor IP Control unit Type / Order-Code Art.-No.


output cont. current
KW A (at 400 V)

w/o FC-102P37KT4 E20 H1 X X ST DS-131F9927


20 numerics FC-102P37KT4 E20 H1 X N ST DS-131F9928
graphics FC-102P37KT4 E20 H1 X G ST DS-131F6630
numerics FC-102P37KT4 E55 H1 X N ST DS-131B7063
37,0 73,0
graphics FC-102P37KT4 E55 H1 X G ST DS-131B7008
55 with integrated mains isolations switch

numerics FC-102P37KT4 E55 H1 X N X1 ST DS-131B7597


graphics FC-102P37KT4 E55 H1 X G X1 ST DS-131B7598
w/o FC-102P45KT4 E20 H1 X X ST DS-131F9932
20 numerics FC-102P45KT4 E20 H1 X N ST DS-131F9933
graphics FC-102P45KT4 E20 H1 X G ST DS-131F0340
numerics FC-102P45KT4 E55 H1 X N ST DS-131B7064
45,0 90,0
graphics FC-102P45KT4 E55 H1 X G ST DS-131B7015
55 with integrated mains isolations switch

numerics FC-102P45KT4 E55 H1 X N X1 ST DS-131B7599


graphics FC-102P45KT4 E55 H1 X G X1 ST DS-131B7600
w/o FC-102P55KT4 E20 H1 X X ST DS-131F9937
20 numerics FC-102P55KT4 E20 H1 X N ST DS-131B9938
graphics FC-102P55KT4 E20 H1 X G ST DS-131F0341

numerics FC-102P55KT4 E55 H1 X N ST DS-131B6771


55,0 106,0
graphics FC-102P55KT4 E55 H1 X G ST DS-131B7025
55 with integrated mains isolations switch

numerics FC-102P55KT4 E55 H1 X N X1 ST DS-131B7601


graphics FC-102P55KT4 E55 H1 X G X1 ST DS-131B7602
w/o FC-102P75KT4 E20 H1 X X ST DS-131F9942
20 numerics FC-102P75KT4 E20 H1 X N ST DS-131F9943
graphics FC-102P75KT4 E20 H1 X G ST DS-131F0342
numerics FC-102P75KT4 E55 H1 X N ST DS-131B9404
75,0 147,0
graphics FC-102P75KT4 E55 H1 X G ST DS-131B8595
55 with integrated mains isolations switch

numerics FC-102P75KT4 E55 H1 X N X1 ST DS-131B5734


graphics FC-102P75KT4 E55 H1 X G X1 ST DS-131F0420

236 C 2018 - Technical changes excepted. Pictures similar.


Danfoss Variable Speed Drive

Effective max. motor IP Control unit Type / Order-Code Art.-No.


output cont. current
KW A (at 400 V)

w/o FC-102P90KT4 E20 H1 X X ST DS-131F9947


20 numerics FC-102P90KT4 E20 H1 X N ST DS-131F9948
graphics FC-102P90KT4 E20 H1 X G ST DS-131F0343
numerics FC-102P90KT4 E55 H1 X N ST DS-131F7530
90,0 177,0
graphics FC-102P90KT4 E55 H1 X G ST DS-131B6204
55 with integrated mains isolations switch

numerics FC-102P90KT4 E55 H1 X N X1 ST DS-131H3166


graphics FC-102P90KT4 E55 H1 X G X1 ST DS-131F7936

Variable Speed Drive


Variable speed drive 110 kW to 400 kW on request

Article Type Art.-No.


BACnet Interface DS-MCA 109 DS-FC102MCA

RS485 wired to clamp


Protocol: MS/TP acc. to ISO 16484-5

Backwall DS-FC102RW1 DS-FC102RW1


for frequency converter IP55 1,1 - 7,5 kW
Backwall DS-FC102RW2 DS-FC102RW2
for frequency converter IP20 / 55 11,0 - 18,5 kW
Backwall DS-FC102RW3 DS-FC102RW3
for frequency converter IP20 / 55 22,0 - 30,0 kW
Backwall DS-FC102RW4 DS-FC102RW4
for frequency converter IP20 / 55 37,0 - 55,0 kW
Backwall DS-FC102RW5 DS-FC102RW5
for frequency converter IP20 / 55 75,0 - 90,0 kW

Other options on request.


The options must be ordered along with the order for the frequency converter as they cannot be imple-
mented at a later date.

Where the frequency converter is mounted separately, i.e. without a backwall, the optional backwall is
necessary. In this case, the backwall ensures the optimum air circulation to prevent overheating.

C 2018 - Technical changes excepted. Pictured products similar. 237


Notice

238 C 2018 - Technical changes excepted. Pictures similar.


Annex

Annex
Annex Page
Information – tranings 234
Information – Terms of delivery 237
Contents - alphabetic sorting 238

C 2018 - Technical changes excepted. Pictured products similar. 239


Training

Modular training concept

Step by step with training modules

FUP XL 2 free
System integration
programming

BACnet with SRU

Basic training

OPENweb

Workshops &
Webinare

In our practical training programs, we teach you to safely and efficiently handle all DEOS products and prepare you for a
subsequent certification as a DEOS system partner.

You acquire sound knowledge of our in-house developed software, gain information about the possible uses of our hardware
and the latest system solutions. We are driven by achieving the greatest possible success of all our partners.

In addition to our regular seminars, we also offer project workshops tailored to our customers on request.

For information about topics, dates and prices of our seminars and workshops, simply contact us!

We look forward to you attending our courses!

240 C 2018 - Technical changes excepted. Pictures similar.


Notice

Annex

C 2018 - Technical changes excepted. Pictured products similar. 241


Notice

242 C 2018 - Technical changes excepted. Pictures similar.


Information – Terms of Delivery

Orders
We are pleased to receive your orders by phone, mail or fax stating the type according to this product
catalog. For technical support or problem solving concerning specific fields of control technology, we are
naturally at your disposal.

Reconsignments
For every reconsignment of goods – irrespective of a legal claim of the customer – the origin invoice, the
origin delivery note and the return reason are needed.

Returns, which are not based on legal claims, are only allowed or unused products of our produvt catalog.
Excluded from this are fitted goods (e. g. cables) and special programs. The reconsignment´s merchandise
net value has to be at least 50,00 EUR.
The goods have to be originally wrapped with undamaged wrapping seal. The period of time between
reconsignment and delivery has to be at most 2 months.

A reconsignment assumes our previous written agreement. In case of an approved reconsignment the cus-
tomer bears the reconsignemt´s costs. We reduce the merchandise value by a charge fee of 15 per cent
for our analyses. We reserve us to reduce the merchandise value for other costs, e.g. in case of damaged
packaging.

General Terms of Business


General terms of business apply basically.
You can review our current general terms and conditions in our office or in the footer of our website www.
deos-ag.com. We can also send you the document, please do not hesitate to contact us!

Annex

C 2018 - Technical changes excepted. Pictured products similar. 243


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page Article-No. Type Page


DS-360020 2030B-A 116 DS-360187 C-Check 103 DS-540054 D632N + SR230A-5 229
DS-360021 2050B-A 116 DS-360188 C-Check-SMS 103 DS-540042 D632N + SR24A-5 228
DS-360022 2080B-A 116 DS-360189 C-Check-Web 103 DS-540139 D6350N + SY6-230-T 230
DS-360023 2160B-A 116 DS-390036 C-DI16 28 DS-540055 D640N + SR230A-5 229
A DS-390035 C-DI8DO8T 29 DS-540043 D640N + SR24A-5 228
DS-475049 AA SK1004 223 DS-390038 C-DO8R 32 DS-540056 D650N + SR230A-5 229
DS-1650403 AFF.LM.USE 159 DS-390039 C-DO8RH 33 DS-540044 D650N + SR24A-5 228
DS-1650404 AFF.Pt1000.USE 159 DS-390040 C-DO8RHS 33 DS-540057 D665N + SR230A-5 229
DS-1650405 AFF.USE 159 DS-390041 C-DO8T 30 DS-540045 D665N + SR24A-5 228
DS-1650179 ALTF.LM.USE 147 DS-390042 C-DO8TH 31 DS-540130 D680N + GR230A-5 229
DS-1650177 ALTF.MR.USE 147 DS-360173 C-Firewall 101 DS-371245 DALI-1S 10
DS-1650178 ALTF.Pt1000.USE 147 DS-360183 C-Mail 102 DS-371246 DALI-2S 10
DS-1650074 ANT10 177, DS-360129 CODI-C 80 DS-371247 DALI-3S 10
178,179
DS-360062 CORA-B 78 DS-371248 DALI-4S 10
DS-1 650075 ANT20 177,
178,179 DS-360063 CORA-B/MD 78 DS-1650082 DLF10V G1/2“ 167

DS-475042 APR 40405-00-373-01 221 DS-360048 CORA-C 79 DS-1650083 DLF16V G1/2“ 167

DS-475041 APR 42405-00-373-01 221 DS-360049 CORA-C/MD 79 DS-1650084 DLF25V G1/2“ 167

DS-475043 AST 20405-00-373-01 220 DS-360164 Cover15, 6 69 DS-1650080 DLF4V G1/2“ 167

DS-475044 AST 40405-00-373-01 220 DS-360165 Cover19, 5 69 DS-1650081 DLF6V G1/2“ 167

DS-1650153 ATF.LM.USE 146 DS-360166 Cover21, 5 69 DS-1650731 DPA250+ AA 169

DS-1650154 ATF.Pt1000.USE 146 DS-475055 CQ230A 142, 213, DS-1650732 DPA250+ AA AZ 169
219
DS-1650001 ATF/SCHUTZ 146, 181 DS-1650733 DPA250+ LCD AA 171
DS-475052 CQ24A 142, 213,
B DS-1650734 DPA250+ LCD AA AZ 171
219
DS-024100 Bat OPEN COS 115 DS-1650729 DPA250+ LCD VV 171
DS-475053 CQ24A-SR 142, 219
DS-024076 Bat B 115 DS-1650730 DPA250+ LCD VV AZ 171
DS-475054 CQK24A-SR 142, 219
DS-024095 Bat OPEN EMS 115 DS-1650737 DPA250+ LCD VV+R 171
DS-350102 CR-ADP 117
DS-390019 BBS 10 41 DS-1650738 DPA250+ LCD VV+R 171
DS-360190 C-Service 103
AZ
DS-390020 BBS 100 41 DS-360174 C-ServPortal 101
DS-1650727 DPA250+ VV 169
DS-080036 Beschriftungsbogen 98 DS-360184 C-SMS 102
grau LVB, LVB-B DS-1650728 DPA250+ VV AZ 169
DS-360175 C-SPGruppe 101
DS-080032 BSET-CORA 80 DS-1650735 DPA250+ VV+R 169
DS-360181 C-vCPU 102
DS-350024 BUS-C0,34 109 DS-1650736 DPA250+ VV+R AZ 169
DS-360182 C-vHDD 102
DS-350036 BUS-C0,5 109 DS-1650743 DPA2500+ AA 169
DS-360176 C-vPC-250 101
DS-350085 BUS-C0,5-H 110 DS-1650744 DPA2500+ AA AZ 169
DS-360177 C-vPC-500 101
DS-350047 BUS-C0,5-N1, 5 109 DS-1650745 DPA2500+ LCD AA 171
DS-360172 C-VPNRED 101
DS-350087 BUS-C0,5-N1,5-H 110 DS-1650746 DPA2500+ LCD AA AZ 171
DS-360180 C-vRAM 102
DS-350025 BUS-C0,75 109 DS-1650741 DPA2500+ LCD VV 171
DS-360179 C-vServer-ADV 102
DS-350086 BUS-C0,75-H 110 DS-1650742 DPA2500+ LCD VV AZ 171
DS-360178 C-vServer-STD 101
DS-350023 BUS-R 111 DS-1650749 DPA2500+ LCD VV+R 171
D
C DS-1650750 DPA2500+ LCD VV+R 171
DS-540134 D6100N + DR230A-5 229 AZ
DS-494119 C215Q-J 142, 219
DS-540126 D6100N + DR24A-5 228 DS-1650739 DPA2500+ VV 169
DS-494122 C320Q-J 142, 219
DS-540096 D6125N + DR230A-7 229 DS-1650740 DPA2500+ VV AZ 169
DS-390037 C-AI8 35
DS-540093 D6125N + DR24A-7 228 DS-1650747 DPA2500+ VV+R 169
DS-390045 C-AI8AO4 36
DS-540135 D6150N + PRCA-S2-T 230 DS-1650748 DPA2500+ VV+R AZ 169
DS-390046 C-AI8AO4H 37
DS-540136 D6200N + PRCA-S2-T 230 DS-1650755 DPA7500+ AA 169
DS-350040 CANRepO 115
DS-540137 D6250W + PRCA-S2- 230 DS-1650756 DPA7500+ AA AZ 169
DS-390043 C-AO4 38 T
DS-1650757 DPA7500+ LCD AA 171
DS-390044 C-AO4H 39 DS-540053 D625N + SR230A-5 229
DS-1650758 DPA7500+ LCD AA AZ 171
DS-360186 C-BedTerm 102 DS-540041 D625N + SR24A-5 228
DS-1650753 DPA7500+ LCD VV 171
DS-360185 C-BedVM 102 DS-540138 D6300W + PRCA-S2- 230
DS-1650754 DPA7500+ LCD VV AZ 171
T

244 C 2018 - Technical changes excepted. Pictures similar.


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page Article-No. Type Page


DS-1650761 DPA7500+ LCD VV+R 171 DS-131B3607 FC-102P11KT4 E55 234 DS-131F6629 FC-102P22KT4 E20 235
H1 X G X1 ST H1 X G ST
DS-1650762 DPA7500+ LCD VV+R 171
AZ DS-131B6765 FC-102P11KT4 E55 234 DS-131F9918 FC-102P22KT4 E20 235
H1 X N ST H1 X N ST
DS-1650751 DPA7500+ VV 169
DS-131B7550 FC-102P11KT4 E55 234 DS-131F9917 FC-102P22KT4 E20 235
DS-1650752 DPA7500+ VV AZ 169
H1 X N X1 ST H1 X X ST
DS-1650759 DPA7500+ VV+R 169
DS-131F6631 FC-102P15KT4 E20 235 DS-131B4268 FC-102P22KT4 E55 235
DS-1650760 DPA7500+ VV+R AZ 169 H1 X G ST H1 X G ST

DS-472032 DWH05-230 195, 199, DS-131B8321 FC-102P15KT4 E20 235 DS-131B4267 FC-102P22KT4 E55 235
203 H1 X N ST H1 X G ST

DS-472028 DWH05-24 195, 198, DS-131F7659 FC-102P15KT4 E20 235 DS-131B6292 FC-102P22KT4 E55 235
202 H1 X X ST H1 X G X1 ST

DS-472020 DWH05-24Y 194, 196, DS-131B6126 FC-102P15KT4 E55 235 DS-131B6768 FC-102P22KT4 E55 235
200 H1 X G ST H1 X N ST

DS-472033 DWH10-230 195, 199, DS-131B7588 FC-102P15KT4 E55 235 DS-131B7593 FC-102P22KT4 E55 235
203 H1 X G X1 ST H1 X N X1 ST

DS-472037 DWH10-230-RE 204 DS-131B7062 FC-102P15KT4 E55 235 DS-131B4218 FC-102P2K2T4 E20 233
H1 X N ST H1 X G ST
DS-472029 DWH10-24 195, 198,
202 DS-131B7587 FC-102P15KT4 E55 235 DS-131B5587 FC-102P2K2T4 E20 233
H1 X N X1 ST H1 X N ST
DS-472036 DWH10-24-RE 204
DS-131F6632 FC-102P18KT4 E20 235 DS-131B7275 FC-102P2K2T4 E20 233
DS-472021 DWH10-24Y 194, 196, H1 X G ST H1 X X ST
200
DS-131F8322 FC-102P18KT4 E20 235 DS-131U0980 FC-102P2K2T4 E55 233
DS-472049 DWH10-24Y-BAC 205, 206, H1 X N ST H1 X G ST
207
DS-131F8652 FC-102P18KT4 E20 235 DS-131U2241 FC-102P2K2T4 E55 233
DS-472046 DWH10-24Y-CAN 205, 206, H1 X X ST H1 X G X1 ST
207
DS-131B3449 FC-102P18KT4 E55 235 DS-131U3976 FC-102P2K2T4 E55 233
DS-472024 DWH10-24Y-N 194, 197, H1 X G ST H1 X N ST
201
DS-131B9551 FC-102P18KT4 E55 235 DS-131U3990 FC-102P2K2T4 E55 233
DS-472039 DWH10-24Y-RE 204 H1 X G X1 ST H1 X N X1 ST
DS-472022 DWH10-24Y-S 194, 197, DS-131B6766 FC-102P18KT4 E55 235 DS-131B5945 FC-102P30KT4 E20 235
201 H1 X N ST H1 X G ST
DS-472034 DWH15-230 195, 199, DS-131B7590 FC-102P18KT4 E55 235 DS-131F9923 FC-102P30KT4 E20 235

Annex
203 H1 X N X1 ST H1 X N ST
DS-472038 DWH15-230-RE 204 DS-131B4207 FC-102P1K1T4 E20 233 DS-131F9922 FC-102P30KT4 E20 235
DS-472030 DWH15-24 195, 198, H1 X G ST H1 X X ST
202 DS-131B5583 FC-102P1K1T4 E20 233 DS-131B5162 FC-102P30KT4 E55 235
DS-472023 DWH15-24Y 194, 196, H1 X N ST H1 X G ST
200 DS-131B5586 FC-102P1K1T4 E20 233 DS-131B6769 FC-102P30KT4 E55 235
DS-472040 DWH15-24Y-RE 204 H1 X N ST H1 X N ST

DS-472025 DWH20-24Y-N 197, 201 DS-131B7526 FC-102P1K1T4 E20 233 DS-131B7595 FC-102P30KT4 E55 235
H1 X X ST H1 X N X1 ST
DS-472035 DWH25-230 199, 203
DS-131U0978 FC-102P1K1T4 E55 233 DS-131F6630 FC-102P37KT4 E20 236
DS-472031 DWH25-24 198, 202 H1 X G ST H1 X G ST
DS-472026 DWH25-24Y 196, 200 DS-131U2239 FC-102P1K1T4 E55 233 DS-131F9928 FC-102P37KT4 E20 236
DS-472027 DWH45-24Y 196, 200 H1 X G X1 ST H1 X N ST

E DS-131U3974 FC-102P1K1T4 E55 233 DS-131F9927 FC-102P37KT4 E20 236


H1 X N ST H1 X X ST
DS-371206 EBM-PST (7DP) 60
DS-131U3992 FC-102P1K1T4 E55 233 DS-131B7008 FC-102P37KT4 E55 236
DS-350069 EIB-01 58 H1 X N X1 ST H1 X G ST
DS-350045 ET31, 5 41 DS-131B4217 FC-102P1K5T4 E20 233 DS-131B7598 FC-102P37KT4 E55 236
H1 X G ST H1 X G X1 ST
F
DS-131B7529 FC-102P1K5T4 E20 233 DS-131B7063 FC-102P37KT4 E55 236
DS-131F0427 FC-102P11KT4 E20 234
H1 X X ST H1 X N ST
H1 X G ST
DS-131U0979 FC-102P1K5T4 E55 233 DS-131B7597 FC-102P37KT4 E55 236
DS-131F8319 FC-102P11KT4 E20 234
H1 X G ST H1 X N X1 ST
H1 X N ST
DS-131U2240 FC-102P1K5T4 E55 233 DS-131B4219 FC-102P3K0T4 E20 233
DS-131F8649 FC-102P11KT4 E20 234
H1 X G X1 ST H1 X G ST
H1 X X ST
DS-131U3975 FC-102P1K5T4 E55 233 DS-131B5590 FC-102P3K0T4 E20 233
DS-131B1277 FC-102P11KT4 E55 234
H1 X N ST H1 X N ST
H1 X G ST
DS-131U3991 FC-102P1K5T4 E55 233 DS-131B7532 FC-102P3K0T4 E20 233
H1 X N X1 ST H1 X X ST

C 2018 - Technical changes excepted. Pictured products similar. 245


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page Article-No. Type Page


DS-131U0981 FC-102P3K0T4 E55 233 DS-131B7544 FC-102P5K5T4 E55 234 DS-600040 FCU T0 V24 139
H1 X G ST H1 X N X1 ST
DS-600048 FCU T0 V240 139
DS-131U2242 FC-102P3K0T4 E55 233 DS-131F0342 FC-102P75KT4 E20 236
DS-600041 FCU T2 V24 139
H1 X G X1 ST H1 X G ST
DS-600049 FCU T2 V240 139
DS-131U3977 FC-102P3K0T4 E55 233 DS-131F9943 FC-102P75KT4 E20 236
H1 X N ST H1 X N ST DS-600042 FCU T4 V24 139
DS-131U3989 FC-102P3K0T4 E55 233 DS-131F9942 FC-102P75KT4 E20 236 DS-600050 FCU T4 V240 139
H1 X N X1 ST H1 X X ST
DS-600043 FPT 24 139
DS-131F0340 FC-102P45KT4 E20 236 DS-131B8595 FC-102P75KT4 E55 236
H1 X G ST H1 X G ST DS-1650109 FST12 174

DS-131F9933 FC-102P45KT4 E20 236 DS-131F0420 FC-102P75KT4 E55 236 DS-1650107 FST3 174
H1 X N ST H1 X G X1ST DS-1650108 FST6 174
DS-131F9932 FC-102P45KT4 E20 236 DS-131B9404 FC-102P75KT4 E55 236 DS-371174 FUP XL 134
H1 X X ST H1 X N ST
DS-371175 FUP-XL.Z 134
DS-131B7015 FC-102P45KT4 E55 236 DS-131B5734 FC-102P75KT4 E55 236
H1 X G ST H1 X N X1 ST G

DS-131B7600 FC-102P45KT4 E55 236 DS-131B3603 FC-102P7K5T4 E20 234 DS-360041 GO 12T al 77
H1 X G X1 ST H1 X G ST DS-360092 GO 12T al BAC 75
DS-131B7064 FC-102P45KT4 E55 236 DS-131B5595 FC-102P7K5T4 E20 234 DS-360038 GO 12T az 77
H1 X N ST H1 X N ST
DS-360089 GO 12T az BAC 75
DS-131B7599 FC-102P45KT4 E55 236 DS-131B7546 FC-102P7K5T4 E20 234
H1 X N X1 ST H1 X X ST DS-360035 GO 12T rw 77
DS-131B3489 FC-102P4K0T4 E20 234 DS-131B4225 FC-102P7K5T4 E55 234 DS-360086 GO 12T rw BAC 75
H1 X G ST H1 X G ST
DS-360039 GO 4T al 77
DS-131B5591 FC-102P4K0T4 E20 234 DS-131B7548 FC-102P7K5T4 E55 234
DS-360090 GO 4T al BAC 75
H1 X N ST H1 X G X1 ST
DS-360036 GO 4T az 77
DS-131B7535 FC-102P4K0T4 E20 234 DS-131B6773 FC-102P7K5T4 E55 234
H1 X X ST H1 X N ST DS-360087 GO 4T az BAC 75
DS-131U0982 FC-102P4K0T4 E55 234 DS-131B7547 FC-102P7K5T4 E55 234 DS-360033 GO 4T rw 77
H1 X G ST H1 X N X1 ST
DS-360084 GO 4T rw BAC 75
DS-131N5656 FC-102P4K0T4 E55 234 DS-131F0343 FC-102P90KT4 E20 237
H1 X G X1 ST H1 X G ST DS-360040 GO 8T al 77

DS-131U3978 FC-102P4K0T4 E55 234 DS-131F9948 FC-102P90KT4 E20 237 DS-360091 GO 8T al BAC 75
H1 X N ST H1 X N ST DS-360037 GO 8T az 77
DS-131U3988 FC-102P4K0T4 E55 234 DS-131F9947 FC-102P90KT4 E20 237 DS-360088 GO 8T az BAC 75
H1 X N X1 ST H1 X X ST
DS-360034 GO 8T rw 77
DS-131F0341 FC-102P55KT4 E20 236 DS-131B6204 FC-102P90KT4 E55 237
H1 X G ST H1 X G ST DS-360085 GO 8T rw BAC 75

DS-131B9938 FC-102P55KT4 E20 236 DS-131F7936 FC-102P90KT4 E55 237 DS-360054 GO-EG 75, 77
H1 X N ST H1 X G X1 ST DS-360042 GO-RD 75, 77
DS-131F9937 FC-102P55KT4 E20 236 DS-131F7530 FC-102P90KT4 E55 237 DS-360044 GO-RG 75, 77
H1 X X ST H1 X N ST
DS-360043 GO-RM 75, 77
DS-131B7025 FC-102P55KT4 E55 236 DS-131H3166 FC-102P90KT4 E55 237
H1 X G ST H1 X N X1 ST DS-371207 GR-PU (7DP) 60

DS-131B7602 FC-102P55KT4 E55 236 DS- FC102RW1 237 DS-350021 GSMANT3 106
H1 X G X1 ST FC102RW1 H
DS-131B6771 FC-102P55KT4 E55 236 DS- FC102RW2 237 DS-471033 H411B 194
H1 X N ST FC102RW2
DS-471034 H412B 194
DS-131B7601 FC-102P55KT4 E55 236 DS- FC102RW3 237
H1 X N X1 ST FC102RW3 DS-471035 H413B 194
DS-131B4220 FC-102P5K5T4 E20 234 DS- FC102RW4 237 DS-471036 H414B 194
H1 X G ST FC102RW4
DS-471037 H415B 194
DS-131B5594 FC-102P5K5T4 E20 234 DS- FC102RW5 237
DS-471038 H420B 194
H1 X N ST FC102RW5
DS-471039 H425B 194
DS-131B7537 FC-102P5K5T4 E20 234 DS-600055 FCT B 2/4P 0-10V 140
H1 X X ST DS-471040 H432B 194
DS-600053 FCT B 2/4P On/Off 140
DS-131B4224 FC-102P5K5T4 E55 234 DS-471041 H440B 194
DS-600056 FCT W 2/4P 0-10V 140
H1 X G ST
DS-471042 H450B 194
DS-600054 FCT W 2/4P On/Off 140
DS-131B7545 FC-102P5K5T4 E55 234
H1 X G X1 ST DS-471001 H511B 194
DS-600036 FCU CT24 139
DS-131B6772 FC-102P5K5T4 E55 234 DS-471002 H512B 194
DS-600037 FCU CT33 139
H1 X N ST

246 C 2018 - Technical changes excepted. Pictures similar.


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page Article-No. Type Page


DS-471003 H513B 194 DS-471057 H650N 200, 201, DS-471023 H740N 200, 201,
202, 203 202, 203
DS-471004 H514B 194
DS-471058 H650R 196, 197, DS-471024 H740R 196, 197,
DS-471005 H515B 194
198, 199, 198, 199,
DS-471006 H520B 194 206 206

DS-471007 H525B 194 DS-471059 H664N 200, 201, DS-471025 H750N 200, 201,
202, 203 202, 203
DS-471008 H532B 194
DS-471060 H664R 196, 197, DS-471026 H750R 196, 197,
DS-471009 H540B 194 198, 199, 198, 199,
DS-471010 H550B 194 206 206

DS-471063 H6100N 200, 201, DS-471061 H679N 200, 201, DS-471027 H764N 200, 201,
202, 203 202, 203 202, 203

DS-471064 H6100R 196, 197, DS-471062 H679R 196, 197, DS-471028 H764R 196, 197,
198, 199 198, 199, 198, 199,
206 206
DS-471043 H611N 200, 201,
202, 203 DS-471031 H7100N 200, 201, DS-471029 H779N 200, 201,
202, 203 202, 203
DS-471044 H611R 196, 197,
198, 199, DS-471032 H7100R 196, 197, DS-471030 H779R 196, 197,
206 198, 199 198, 199,
206
DS-471065 H6125S 200, 201, DS-471011 H711N 200, 201,
202, 203 202, 203 DS-530020 HA206D 94

DS-471073 H612N 200, 201, DS-471012 H711R 196, 197, DS-530021 HA406D 94
202, 203 198, 199,
DS-530043 HA407D 94
206
DS-471070 H612R 196, 197, DS-1650045 HF0-20 160
198, 199, DS-471067 H7125N 200, 201,
206 202, 203 DS-530001 HGL 84

DS-471045 H613N 200, 201, DS-471075 H712N 200, 201, DS-530002 HGLN 84
202, 203 202, 203
DS-530035 HK201R 95
DS-471046 H613R 196, 197, DS-471072 H712R 196, 197,
198, 199, DS-530036 HK261R 95
198, 199,
206 206 DS-530003 HM599A 85
DS-471074 H614N 200, 201, DS-471013 H713N 200, 201, DS-530033 HM599B 85
202, 203 202, 203
DS-530004 HM699A 85
DS-471071 H614R 196, 197, DS-471014 H713R 196, 197,

Annex
198, 199, DS-530034 HM699B 85
198, 199,
206 206 DS-530007 HS122R 87
DS-471066 H6150S 200, 201, DS-471076 H714N 200, 201, DS-530012 HS122X 89
202, 203 202, 203
DS-530009 HS133R 87
DS-471047 H615N 200, 201, DS-471069 H714R 196, 197,
202, 203 198, 199, DS-530018 HS165R 92
206
DS-471048 H615R 196, 197, DS-530031 HS165X 93
198, 199, DS-471068 H7150N 200, 201,
DS-530005 HS211R 86
206 202, 203
DS-530010 HS211X 88
DS-471049 H620N 200, 201, DS-471015 H715N 200, 201,
202, 203 202, 203 DS-530040 HS219R 86

DS-471050 H620R 196, 197, DS-471016 H715R 196, 197, DS-530038 HS21FU1R 97
198, 199, 198, 199,
206 DS-530008 HS222R 87
206
DS-471017 H720N 200, 201, DS-530013 HS222X 89
DS-471051 H625N 200, 201,
202, 203 202, 203 DS-530014 HS254R 90
DS-471052 H625R 196, 197, DS-471018 H720R 196, 197, DS-530016 HS254X 91
198, 199, 198, 199,
206 DS-530019 HS265R 92
206
DS-471019 H725N 200, 201, DS-530032 HS265X 93
DS-471053 H632N 200, 201,
202, 203 202, 203 DS-530006 HS411R 86
DS-471054 H632R 196, 197, DS-471020 H725R 196, 197, DS-530011 HS411X 88
198, 199, 198, 199,
206 206 DS-530015 HS454R 90

DS-471055 H640N 200, 201, DS-471021 H732N 200, 201, DS-530017 HS454X 91
202, 203 202, 203 DS-530022 HT297R 96
DS-471056 H640R 196, 197, DS-471022 H732R 196, 197, DS-530023 HT497R 96
198, 199, 198, 199,
206 206 DS-530030 HZB1 98
DS-530026 HZR10 98

C 2018 - Technical changes excepted. Pictured products similar. 247


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page Article-No. Type Page


DS-530037 HZR10-19 98 DS-371220 MOD MA25 59 DS-360134 OPEN 710/12 EMS + 12
M-Bus
DS-530024 HZR5 98 DS-371171 MOD MA250 59
DS-360103 OPEN 710/12 EMS 9
DS-530025 HZR8 98 DS-371170 MOD MA50 59
DS-360128 OPEN 710/32 EMS 11
DS-530029 HZV10 98 DS-371194 MOD MA500 59
+ DALI
DS-530027 HZV5 98 DS-371169 MOD SL 59
DS-360135 OPEN 710/32 EMS + 12
DS-530028 HZV8 98 DS-350020 MODGSM3 105 M-Bus

I DS-350065 MODNTZ125 106 DS-360104 OPEN 710/32 EMS 9

DS-390013 IO7 45 DS-390047 MT-R 42 DS-360126 OPEN 710/5 EMS + 11


DALI
DS-390012 IO7-B 44 DS-1670027 MWF+ 3000.Pt1000 173
DS-360133 OPEN 710/5 EMS + 12
J DS-1670041 MWF+ 6000.Pt1000 173 M-Bus
DS-1650172 JOY -S 141 N DS-360102 OPEN 710/5 EMS 9
DS-1650144 JOY-W 141 O DS-360152 OPEN 810/0 EMS + 13
K DS-371261 Odyn16 63 M-Bus

DS-1650191 KFF.LM.USE 158 DS-371262 Odyn32 63 DS-360139 OPEN 810/0 EMS 8

DS-1650192 KFF.Pt1000.USE 158 DS-371263 Odyn48 63 DS-360153 OPEN 810/0 EMS + 11


DALI
DS-1650190 KFF.USE 158 DS-371259 OE.Y 122
DS-360137 OPEN 810/12 EMS + 13
DS-1650200 KLTF.LM 148 DS-371234 OE00 122 M-Bus
DS-1670002 KLTF.Pt1000 148 DS-371228 OE100 122 DS-360100 OPEN 810/12 EMS 8
DS-360010 KNX IP Interface 731 56 DS-371231 OE1000 122 DS-360124 OPEN 810/12 EMS 11
DS-1650657 KRM-1 186 DS-371253 OE150 122 + DALI

DS-1650655 KRM-1-DZ 184 DS-371232 OE2000 122 DS-360138 OPEN 810/32 EMS + 13
M-Bus
DS-1650658 KRM-2 186 DS-371226 OE25 122
DS-360101 OPEN 810/32 EMS 8
DS-1650656 KRM-2-DZ 184 DS-371229 OE250 122
DS-360125 OPEN 810/32 EMS 11
DS-1650660 KS 187 DS-371227 OE50 122 + DALI
DS-1650661 KS-WDG 187 DS-371230 OE500 122 DS-360136 OPEN 810/5 EMS + 13
M-Bus
L DS-371233 OE5000 122
DS-360099 OPEN 810/5 EMS 8
DS-1650130 LCF Touch MODBUS 141 DS-371254 OE750 122
DS-360123 OPEN 810/5 EMS + 11
DS-1650536 LK+ CO2 3xV 164 DS-371260 OE-UP 122
DALI
DS-1650537 LK+ CO2 V 164 DS-360097 OPEN 3100 EMS C1 6
DS-371123 OPEN EIB 1000 58
DS-1650535 LK+ CO2 VV 164 DS-360098 OPEN 3100 EMS C2 6
DS-371121 OPEN EIB 250 58
DS-1650538 LK+ VOC V 161 DS-360093 OPEN 4100 EMS C1 4
DS-371198 OPEN EIB 50 58
DS-360109 LONBAC-950 60 DS-360095 OPEN 4100 EMS 25
DS-371197 OPEN EIB 500 58
C1/R
M
DS-371218 OPENapp HLK 600/0 65
DS-360094 OPEN 4100 EMS C2 4
DS-371135 MakBib 135
DS-371219 OPENapp HLK 600/5 65
DS-360096 OPEN 4100 EMS 25
DS-371258 MakTpl 135
C2/R DS-371251 OPENapp PU 600/0 65
DS-024087 MBus-H20 57
DS-360081 OPEN 500/0 EMS 18 DS-371252 OPENapp PU 600/5 65
DS-024089 MBus-H250 57
DS-360080 OPEN 500/5 EMS 18 DS-371249 OV App 132
DS-024086 MBus-H3 57
DS-360083 OPEN 500H/0 EMS 18 DS-371210 OV0 133
DS-024088 MBus-H60 57
DS-360082 OPEN 500H/5 EMS 18 DS-371188 OV12 133
DS-FC102M- MCA 109 - eingebaut 237
DS-360077 OPEN 600/0 EMS 14 DS-371189 OV32 133
CA
DS-360160 OPEN 600/0 EMS 16 DS-371187 OV5 133
DS-FC102M- MCA 109 - Erweite- 239
basic24
CA-E rung DS-371190 OVC1 133
DS-360075 OPEN 600/5 EMS 14
DS-1650510 MDS-S1 175 DS-371191 OVC2 133
DS-360079 OPEN 600H/0 EMS 14
DS-360168 MiniPC-Ad 69 DS-371250 OW App 131
DS-360078 OPEN 600H/5 EMS 14
DS-360167 MiniPC-B 69 DS-371205 OWB.A 128
DS-360154 OPEN 710/0 EMS 9
DS-350048 MOD A 106 -schwarz-. 104 DS-371196 OWB.BAC.F 128
DS-360155 OPEN 710/0 EMS + 11
DS-3500168 MOD GW 56 DS-371168 OWB.BAC00 130
DALI
DS-350049 MOD I 106 -schwarz- 104 DS-371165 OWB.BAC10 130
DS-360156 OPEN 710/0 EMS + 12
DS-371264 MOD MA 100 59 M-Bus DS-371238 OWB.BAC100 130
DS-371195 MOD MA1000 59 DS-360127 OPEN 710/12 EMS 11 DS-371163 OWB.BAC2 130
+ DALI

248 C 2018 - Technical changes excepted. Pictures similar.


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page Article-No. Type Page


DS-371166 OWB.BAC20 130 DS-480019 PLD20-24-BAC 224 DS-494081 R2032-B2 214
DS-371239 OWB.BAC200 130 DS-480021 PLD20-24-CAN 224 DS-494082 R2032-S3 214
DS-371235 OWB.BAC30 130 DS-480026 PLD20-24-S2-FR 226 DS-494013 R2040-16-S3 210
DS-371236 OWB.BAC40 130 DS-480008 PLD20-24Y 224 DS-494014 R2040-25-S3 210
DS-371164 OWB.BAC5 130 DS-480024 PLD20-24Y-FR 226 DS-494083 R2040-S3 214
DS-371167 OWB.BAC50 130 DS-480011 PLD40-230 225 DS-494015 R2050-25-S4 210
DS-371237 OWB.BAC75 130 DS-480010 PLD40-24 225 DS-494016 R2050-40-S4 210
DS-371158 OWB.E 128 DS-480012 PLD40-24Y 224 DS-494118 R2050-S4 214
DS-371161 OWB.O 128 DS-480001 PLD5-230 225 DS-495019 R3015-1-1-B2 216
DS-371160 OWB.S 128 DS-480000 PLD5-24 225 DS-495020 R3015-1-1P3-B2 216
DS-371225 OWB.Y 129 DS-480002 PLD5-24Y 224 DS-495016 R3015-1-P25-B2 216
DS-371224 OWB.Z 129 DS-1650528 PS 1500 168 DS-495024 R3015-1P3-1-B2 216
DS-371155 OWB00 127 DS-350160 PS 24-0.42 107 DS-495025 R3015-1P3-1P3-B2 216
DS-371173 OWB00prof 129 DS-350161 PS 24-1.25 107 DS-495021 R3015-1P3-P25-B2 216
DS-371152 OWB10 127 DS-350162 PS 24-2.50 107 DS-495022 R3015-1P3-P4-B2 216
DS-371214 OWB100 127 DS-350163 PS 24-4.20 107 DS-495023 R3015-1P3-P63-B2 216
DS-371150 OWB2 127 DS-1650511 PS 300 166 DS-495017 R3015-1-P4-B2 216
DS-371153 OWB20 127 DS-1650512 PS 500 166 DS-495018 R3015-1-P63-B2 216
DS-371215 OWB200 127 DS-1650522 PS-MW 166 DS-494019 R3015-1P6-S1 211
DS-371221 OWB30 127 DS-492006 PWD05-230 214, 215 DS-494018 R3015-1-S1 211
DS-371222 OWB40 127 DS-492005 PWD05-24 214, 215 DS-494020 R3015-2P5-S1 211
DS-371151 OWB5 127 DS-492000 PWD05-24-BAC 210-213, DS-494021 R3015-4-S1 211
216, 217
DS-371154 OWB50 127 DS-495004 R3015-P25-1-B2 216
DS-492002 PWD05-24-CAN 210-213,
DS-371223 OWB75 127 DS-495005 R3015-P25-1P3-B2 216
216, 217
DS-371208 OWB-UP 126 DS-495001 R3015-P25-P25-B2 216
DS-492004 PWD05-24Y 210-213,
P 216, 217 DS-495002 R3015-P25-P4-B2 216
DS-480015 P10000A-GR 227 DS-492001 PWD10-24-BAC 210-213, DS-495003 R3015-P25-P63-B2 216
216, 217

Annex
DS-350061 Patchkabel 05 117 DS-495009 R3015-P4-1-B2 216
DS-492003 PWD10-24-CAN 210-213,
DS-350060 Patchkabel 1 117 216, 217 DS-495010 R3015-P4-1P3-B2 216
DS-350005 Patchkabel10 117 DS-492009 PWD20-230 210-215 DS-495006 R3015-P4-P25-B2 216
DS-350080 Patchkabel15 117 DS-492008 PWD20-24 210-215 DS-495007 R3015-P4-P4-B2 216
DS-350002 Patchkabel2 117 DS-492007 PWD20-24Y 210-213 DS-495008 R3015-P4-P63-B2 216
DS-350012 Patchkabel20 117 Q DS-495014 R3015-P63-1-B2 216
DS-350003 Patchkabel3 117 R DS-495015 R3015-P63-1P3-B2 216
DS-350013 Patchkabel30 117 DS-494002 R2015-1P6-S1 210 DS-495011 R3015-P63-P25-B2 216
DS-350004 Patchkabel5 117 DS-494001 R2015-1-S1 210 DS-495012 R3015-P63-P4-B2 216
DS-350079 Patchkabel7,5 117 DS-494003 R2015-2P5-S1 210 DS-495013 R3015-P63-P63-B2 216
DS-350046 PES 41 DS-494004 R2015-4-S1 210 DS-494017 R3015-P63-S1 211
DS-390022 PKM - 2x - 40 DS-494005 R2015-6P3-S1 210 DS-494084 R3015-S1 214
DS-390024 PKM -schwarz- 40 DS-494000 R2015-P63-S1 210 DS-495028 R3020-1-1P6-B2 217
DS-480004 PLD10-230 225 DS-494078 R2015-S1 214 DS-495029 R3020-1-2P5-B2 217
DS-480003 PLD10-24 225 DS-494006 R2020-4-S2 210 DS-495031 R3020-1P6-1-B2 217
DS-480018 PLD10-24-BAC 224 DS-494007 R2020-6P3-S2 210 DS-495033 R3020-1P6-2P5-B2 217
DS-480020 PLD10-24-CAN 224 DS-494008 R2020-8P6-S2 210 DS-495030 R3020-1P6-P63-B2 217
DS-480025 PLD10-24-S2-FR 226 DS-494079 R2020-S2 214 DS-495035 R3020-2P5-1-B2 217
DS-480005 PLD10-24Y 224 DS-494010 R2025-10-S2 210 DS-495036 R3020-2P5-1P6-B2 217
DS-480023 PLD10-24Y-FR 226 DS-494011 R2025-16-S2 210 DS-495037 R3020-2P5-2P5-B2 217
DS-480007 PLD20-230 225 DS-494009 R2025-6P3-S2 210 DS-495034 R3020-2P5-P63-B2 217
DS-480009 PLD20-230Y 224 DS-494080 R2025-S2 214 DS-494022 R3020-4-S2 211
DS-480006 PLD20-24 225 DS-494012 R2032-16-S3 210 DS-494023 R3020-6P3-S2 211

C 2018 - Technical changes excepted. Pictured products similar. 249


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page Article-No. Type Page


DS-495026 R3020-P63-1P6-B2 217 DS-493101 R532 215 DS-024023 SUBCON9/F 114
DS-495027 R3020-P63-2P5-B2 217 DS-493056 R538 213 DS-360005 SW5 116
DS-494085 R3020-S2 214 DS-493102 R540 215 DS-360059 SW8-230 116
DS-494025 R3025-10-S2 211 DS-493057 R548 213 T
DS-494024 R3025-6P3-S2 211 DS-493103 R550 215 DS-1650720 THMS050.06 180
DS-494086 R3025-S2 214 DS-1650563 RF2P2STD.LM 152 DS-1650721 THMS100.06 180
DS-494026 R3032-16-S3 211 DS-1670019 RF2P2STD.Pt1000 152 DS-1650722 THMS150.06 180
DS-494087 R3032-B2 214 DS-1650564 RF2P3STD.LM 153 DS-1650723 THMS200.06 180
DS-494088 R3032-S3 214 DS-1670020 RF2P3STD.Pt1000 153 DS-1650724 THMS250.06 180
DS-494027 R3040-16-S3 211 DS-1650351 RFF.A 156 DS-1650725 THMS300.06 180
DS-494089 R3040-S3 214 DS-1650501 RFF/TF.A.LM 157 DS-1650726 THMS450.06 180
DS-494028 R3050-25-S4 211 DS-1650651 RFP.A.LM 155 DS-1650710 THVA050.06 180
DS-494090 R3050-S4 214 DS-1670017 RFP.A.Pt1000 155 DS-1650711 THVA100.06 180
DS-493029 R409 212 DS-520002 RFPTD1.A.LM 151 DS-1650712 THVA150.06 180
DS-493030 R410 212 DS-520009 RFPTD1.A.Pt1000 151 DS-1650713 THVA200.06 180
DS-493031 R411 212 DS-1650650 RFTD.A.LM 154 DS-1650714 THVA250.06 180
DS-493032 R412 212 DS-1670016 RFTD.A.Pt1000 154 DS-1650715 THVA300.06 180
DS-493033 R413 212 DS-024081 RJ45DK9DE 56 DS-1650716 THVA450.06 180
DS-493034 R414 212 DS-024082 RJ45DK9PC 58, 115 DS-360157 Touch PC 10.1“, 70
Android
DS-493091 R415 215 DS-360019 RJ45H 116
DS-360161 Touch15, 6 69
DS-493035 R417 212 DS-1650602 RLQF 162
DS-360162 Touch19, 5 69
DS-493036 R418 212 DS-024022 RS232mf1:1 56
DS-360163 Touch21, 5 69
DS-493037 R419 212 DS-1670039 RTF.I.LM.USE 150
DS-1650155 TTF/KTF.050.LM.USE 144
DS-493092 R420 215 DS-1670040 RTF.I.Pt1000.USE 150
DS-1650165 TTF/KTF.050.MR.USE 145
DS-493038 R422 212 DS-1650520 RTF/Schutz 181
DS-1670032 TTF/KTF.050.Pt1000. 144
DS-493039 R423 212 DS-520001 RTF1.A.LM 149
USE
DS-493040 R424 212 DS-520008 RTF1.A.Pt1000 149
DS-1650156 TTF/KTF.100.LM.USE 144
DS-493093 R425 215 S
DS-1650166 TTF/KTF.100.MR.USE 145
DS-493094 R430 215 DS-480028 S2A-F-GR 227
DS-1670033 TTF/KTF.100.Pt1000. 144
DS-493041 R431 212 DS-480017 S2A-GR 227 USE

DS-493095 R432 215 DS-473022 S2A-H 227 DS-1650157 TTF/KTF.150.LM.USE 144

DS-493042 R438 212 DS-1650567 SPB100 147, 181 DS-1650167 TTF/KTF.150.MR.USE 145

DS-493043 R439 212 DS-1650565 SPS110 147, 181 DS-1670034 TTF/KTF.150.Pt1000. 144
USE
DS-493096 R440 215 DS-1650566 SPS250 147, 181
DS-1650158 TTF/KTF.200.LM.USE 144
DS-493044 R448 212 DS-1650070 SR04 176
DS-1650168 TTF/KTF.200.MR.USE 145
DS-493045 R449 212 DS-1650071 SR04P 176
DS-1670035 TTF/KTF.200.Pt1000. 144
DS-493097 R450 215 DS-1650072 SR0-AD0 4AA/2DA 177 USE
DS-493046 R509 213 DS-1650073 SR0-AD0 4AA/4DA 177 DS-1650159 TTF/KTF.250.LM.USE 144
DS-493047 R510 213 DS-1650089 SRC65-BACnet 179 DS-1650169 TTF/KTF.250.MR.USE 145
DS-493048 R511 213 DS-340003 SRU 48 DS-1670036 TTF/KTF.250.Pt1000. 144
DS-493049 R512 213 DS-340004 SRU+4DO 50 USE

DS-493050 R513 213 DS-340007 SRU+KNX 51 DS-1650160 TTF/KTF.300.LM.USE 144

DS-493098 R515 215 DS-340008 SRU+MOD 52 DS-1650170 TTF/KTF.300.MR.USE 145

DS-493051 R517 213 DS-340006 SRU-Prg 1 53 DS-1670037 TTF/KTF.300.Pt1000. 144


USE
DS-493052 R518 213 DS-350101 SSU DE311 V3.0 113
DS-1650161 TTF/KTF.450.LM.USE 144
DS-493099 R520 215 DS-350100 SSU IA5150 V1.3 112
DS-1650171 TTF/KTF.450.MR.USE 145
DS-493053 R522 213 DS-350167 SSU IA5150I isolated 112
DS-1670038 TTF/KTF.450.Pt1000. 144
DS-493054 R523 213 DS-140410 SSURS232/TTY 114 USE
DS-493100 R525 215 DS-360069 SSURS232RS485 114 DS-360071 TUP.102 73
DS-493055 R531 213 DS-1650124 STC65-MODBUS 178 DS-360106 TUP.103 72

250 C 2018 - Technical changes excepted. Pictures similar.


Contents - alphabetic sorting

Article-No. Type Page Article-No. Type Page


U DS-473011 ZH4540 218
DS-600044 UPT 139 DS-473012 ZH4550 218
DS-024061 USB RS232 116 DS-491430 ZR2315 218
DS-024084 USB-CAN 115 DS-491431 ZR2320 218
V DS-491432 ZR2325 218
DS-475016 VA 59 222 DS-491433 ZR2332 218
DS-475032 VA02 223 DS-491434 ZR2340 218
DS-475010 VA04H 222 DS-491435 ZR2350 218
DS-475011 VA10 222, 223 DS-491424 ZR4515 218
DS-475020 VA16 222 DS-491425 ZR4520 218
DS-475024 VA16H 222 DS-491426 ZR4525 218
DS-475026 VA20H 223 DS-491427 ZR4532 218
DS-475018 VA26 222 DS-491428 ZR4540 218
DS-475019 VA26H 222 DS-491429 ZR4550 218
DS-475029 VA32 223
DS-475023 VA39 222
DS-475013 VA50 222
DS-475022 VA54 222
DS-475031 VA62H 223
DS-475014 VA70H 222
DS-475030 VA70H 223
DS-475017 VA72 222
DS-475015 VA78 222
DS-475012 VA80 222, 223
DS-475021 VA81H 222
DS-475028 VA91 223
DS-475025 VA94 223

Annex
DS-475027 VA97 223
DS-600033 VAV T4 138
DS-600051 VAV CT24 138
DS-600052 VAV CT33 138
DS-600031 VAV T0 138
DS-600032 VAV T2 138
DS-600034 VAV T4X 138
DS-600035 VPT 24 138
W
DS-1650659 WDG 187
DS-350126 WH 41
DS-1650122 WK01+ 24V 172
DS-1650518 WRF04 CO2 VV 163
DS-1650519 WRF04 CO2 VV rH 163
3xV
DS-1650534 WRF04 CO2 VV TLF 163
DS-600038 WTS 10K 138, 139
X
Y
Z
DS-473007 ZH4515 218
DS-473008 ZH4520 218
DS-473009 ZH4525 218
DS-473010 ZH4532 218

C 2018 - Technical changes excepted. Pictured products similar. 251


System topology

OPENenergy OPENweb

OPENweb App OPENview

Client Server Client Server Mobile LED touch


screen 15,6“ to
21,6“

BACnet/IP TCP/IP

OPEN 3100 EMS OPEN 710 EMS OPEN 500 EMS


OPEN 4100 EMS OPEN 810 EMS OPEN 600 EMS
(Native BACnet Controller) (Native BACnet Controller)
(Native BACnet Controller)

max. 4000 BACnet objects max. 1000 BACnet objects max. 250 BACnet objects
max. 4000 physical data points max. 512 physical data points max. 112 physical data points
32 integrated IOs

CAN C2 CAN C1 CAN CAN


RS232 RS232 RS232
USB USB RS485
RS485 DALI
RS485
M-Bus

Room Solutions
FCU series VAV series OPEN SRU
up to 20 integrated IOs up to 10 integrated IOs (BACnet single room unit)
up to 20 integrated IOs

BACnet MS/TP BACnet MS/TP BACnet MS/TP

or or
CAN local
MODBUS RTU MODBUS RTU RS485 (MODBUS)
KNX

252 C 2018 - Technical changes excepted. Pictures similar.


System topology

CORA GALAXY One

TUP Embedded CAN


5,7“ and 3,5“ Touch-PC 10.1“
BACnet MS/TP

OPEN 600 EMS basic24


(Native BACnet Controller)
PLDx-24-CAN PWDx-24-CAN DWH10-24Y-CAN
max. 250 BACnet objects
max. 24 physical data points PLDx-24-BAC PWDx-24-BAC DWH10-24Y-BAC
24 integrated IOs

AI 0...10V

AI AI 0...10V
0...10V
AI
PT 1000
AI AI AI AI Ni 1000
(only BACnet)
CAN CAN 10 mV/K
RS232 (only CAN)
RS485
CAN
BACnet MS/TP BACnet MS/TP

BACnet MS/TP

System Integration
RS232
RS485 TCP/IP
M-Bus BACnet/IP

KNX-IP TCP/IP
TCP/IP
KNX-TP RS232
RS232 RS485 RS485

RS485 RS485 DALI

further connections on rquest

C 2018 - Technical changes excepted. Pictured products similar. 253


254 C 2018 - Technical changes excepted. Pictures similar.
C 2018 - Technical changes excepted. Pictured products similar. 255
h-x-diagram
Mollier-h-x- diagram for humid air at an atmospheric pressure of 1.013 bar (0.000 m / 10.000 °C / 80.000 % rH)

256 C 2018 - Technical changes excepted. Pictures similar.


Technology for
intelligent buildings

DEOS AG is a technology leader and innovator for building automation. We have


been developing and distributing intelligent and comprehensive Digital Energy
Optimization Systems for building automation that strike the perfect balance
between comfort, energy efficiency and cost transparency for more than 50 years.

Address Contact
DEOS AG +49 5971 91133-0 Find more information about
Birkenallee 76 +49 5971 91133-2999 your local distributor on our
48432 Rheine info@deos-ag.com website www.deos-ag.com.
Germany www.deos-ag.com