1. The document outlines zoning regulations for different types of industrial areas, including general industrial (Zone I) and hi-tech industrial (Zone I-H). 2. It specifies the maximum floor area ratios, ground coverage, and minimum setback distances for plots of different sizes. Higher plots have more relaxed norms. 3. Parking requirements are also outlined, mandating one car parking spot for every 150 sqm of floor area and lorry parking for every 1000 sqm, with basement/multilevel parking required for hi-tech zones.

Uploaded by

Pragna Shree
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views4 pages

Industrial Building Regulations Overview

1. The document outlines zoning regulations for different types of industrial areas, including general industrial (Zone I) and hi-tech industrial (Zone I-H). 2. It specifies the maximum floor area ratios, ground coverage, and minimum setback distances for plots of different sizes. Higher plots have more relaxed norms. 3. Parking requirements are also outlined, mandating one car parking spot for every 150 sqm of floor area and lorry parking for every 1000 sqm, with basement/multilevel parking required for hi-tech zones.

Uploaded by

Pragna Shree
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

iozobs duor-t;d

dCI.* lvinafl

3)

d":."0-
at e.t) br-rlo

mntJ
0 o$od9

6 Flsor
xoeicQejtJ,

d 15.7.20t5,
28.9.2015.
6.t1.2015,
rg.lt.z,8ls
,ii aiaisi,
A*eJ) dyfncd.:,

c$ilelqdBEtD wdoe$:;rb*: t,ro0* 6A


esfiqri 6?rla Dd tscEeeor;:Jnroiiigl-i
ri{s$aarbdod' n, iiddoab€ FroorArea Ratio ab* Ground
coverage 'edtStiai
1 . ZONE-I - Industrial (General).
(GeneralIndustries,
Manufacturing,
Auto Mobire,processing,
Industries) Redcategoryand suchother
1.1 For roadwidth from 12mto lgm
st. Extent of the"Blot Ground FAR Setbacks,
(m)
No (sq.m.) Coverage Front Rear sid es
t . *
,+4\J r E a

I Up to 2150 75% t.50 4.50 ?(n 50


2 Above250 Up to 500 75 Yo r.50 4.50 3.00 n
l0
J Above500Upto 1000 65% 1.75 4.s0 4.50 4 r0
4 Above1000Up to 2000 60% 115 8.00 6.00 6 )0
) Above2000Up to 4000 s5% 2.00 r0.00 8.00 8 00
6 Above4000Up to 8000 55% 2.00 r0.00 8.00 8 )0
a
Above8000 2.2s
J)"/o 10.00 8.00 8 )0

l.2For roadwidthabovelgm.

st. Exteiltof theplot Ground FAR


No Set$acks,m )
(sq.mJ Coverage
Front Rear Sires
Up to 250 75 yo 1 . 7 s5 4.50 2.50 0
2 Above250Up to 500 75% 1.75 4.50 3.00 a
J. 0
.5 Above500Up to 1000 65% 2.00 4.50 4.50 4. 0
4 Above 1000Up to 2000 60% 2.00 8.00 6.00 6.q0
5 Above2000Up to 4000 55% 2.2s r 0 . 0 0 8.00 8. c
6 Above4000Up to 8000 550 2.?s r0.00 8.00 8.1l

7 Above 8000 2.50


550 r 0 . 0 0 8.00 8.( )
Note:
I . Theabovenormsareapplicable
for buildingheightuptol5 m.
z . Irorbuildings
of heightthatareequarto andabove.
beobtainedfrom of Fire ForceA'e."rg";"y r 5 m, separate
approvar requiredto
ServicesDepartn[ent. [s

J. whereroadwidth is*fesstfran12m or
not fail in theabove
-'' - -*'v6vr
catEgory,guideri
prescribed
for nearestroadwidthst outJue torto*ea.

2. Zone-I(H)- Industrial (Hi-Tech)


- 't' *'
ArfF* E

st. Extentof the Ground FAR


Setbaclis(m)
No Plotsq.m) Coverage Road widt (m)
Front Rear&
sides
r0r netgntof the buildingup
to l5m.
I Upto1000 l- ' 2 . 0 0 4.50
4.50
"'n | Uptor

2 Above1000
upto2000 ss% 2.25 6.00 6.00

Abovel2 upt o 1 8
Above2000
J
upto4000 s5% 2.50 10.00 8.00

4
Above4000
upto6000 60% 3.00 10.00 8.00
Above24upo 3 0
5 Above6000 60% 3.2s 12.00
f

10.00

ourtdingequal lo and above l 5 m . '

J.UU .{bove24 up r 3 0
10.00 8.00
7 Above8000 60% 3.25 r 2.00
r0.00 Above3(
Nste:
l . For the heightof the buirdingequar
to and above15.00m, Nqc frorn F,i Fc,rc€
EmergencyServicesDepartrient'ismand"tory C,fCe&
and .r* ir,.tr"tuu"t, pl :ribed
ibed in
Natio--nal-Buildjne
code/FireForce& E*..g"n"y services
for building Depa{tment sharl foilor
rilowed
of hJghtmorerhan15.00m.

whereroadwidth is ressthanrzm or not


fail in theabovecategoly,gui.derine
prescribed
for nearest
roadwidthshouldbe followed,.
?".J Indusrria
?""J Indusrria
| (Genera
(Genera
l):
one car parkingof 2.5 m x5.5
m eachshat be providedfor every
I50 sq. m f floorareaplus
one
onelorry
lorry space
spacemeasuring
measurins y ? + * r^_--__
? Sm X
3.5 7.5m forevery I000sq., ., ,;rr*rr*,.

Zan e-l (H-).I,ndustria


| (Hi-tech):
1'
. OneCarparkingof 2.5m X 5.5m eachshallb4p,6,iru?A
for ei,ery50sq m of floor area.
' Theindustries
shalIcompursoriry
providebasementlmurti_stiriea
parking

p+z?e

ruordd eFed
:6.
*tda6
) (g)
fOroof
ad0fi:
qDrr-
* ds €d$r,,
; '{#t?l*;^t33:ff-e r00Eeds*)4

dSrlS::
I'
:91T' lO-ol+fq?p"r!ahderddcb,
aJdd, denrd,oexirr
sornqro
O{-a:ort*oO.
,. ra_o$rilraaieoo
*o, ' aorto foooFCIaardrxl,- ". * n:\An

F*TP$q ,Po--n, so. on.-,s* abda,*"|.fi;c^rei.r''


dexi"d,oesor'dd^,
eiorlcocb. "l 9JdcJ'

,, Eeo$o-dcb 6iorb dDsD.


P*n .d erad"QoQa,oo,
deco6er,
oe^,,furJ;ii, xon*"*. 9JaGJr

Eacoaet,
e)0esq]dd,.dexi"*.oe:i"r
I $C*.arAxgalcb,

I .-ld,
;H:--'*TT'*PSffi??-n"":lT*
"-P
dd.

6. ola;rd aero a:o{^3Oderddclc,


drneoao c"bd) ilodeid
7. ulsndaa ddg / a3z$;.dO
a,.anfi.

You might also like