Professional Documents
Culture Documents
Training manual
2012 Version 17
April 1
2.6.4 Creating Cantilever Slabs ............................................................................................................................................. 54
2.6.5 Additional Slab Information ......................................................................................................................................... 56
2.7 Member Re-Labelling ..................................................................................................................................................... 57
2.7.1 Exercise Aims ............................................................................................................................................................... 57
2.7.2 Changing the member labels ....................................................................................................................................... 57
2.8 Using Tables to Edit Multiple Members ......................................................................................................................... 58
2.8.1 Exercise Aims ............................................................................................................................................................... 58
2.8.2 Changing Properties of Multiple Members ................................................................................................................. 58
2.8.3 Changing Properties of One Member in the table only ............................................................................................... 59
2.9 Wall Loads and Additional Beam Loads .......................................................................................................................... 60
2.9.1 Exercise Aims ............................................................................................................................................................... 60
2.9.2 Apply Beam Wall Loads................................................................................................................................................ 60
2.9.3 Apply Additional Beam Loads ...................................................................................................................................... 62
2.10 Generating a 3D View of the Model and Creating Additional Storeys ........................................................................... 65
2.10.1 Exercise Aims ............................................................................................................................................................... 65
2.10.2 Generating/Manipulating a 3D View ........................................................................................................................... 65
2.10.3 Inserting Additional Floors ........................................................................................................................................... 67
2.10.4 Copying Floor Data to Other Floors ............................................................................................................................. 68
2.10.5 Moving between Storeys ............................................................................................................................................. 68
2.10.6 Editing the Roof ........................................................................................................................................................... 69
2.10.7 Editing the Storey Height ............................................................................................................................................. 69
2.10.8 Specifying Imposed Load Reductions for Each Floor ................................................................................................... 70
3.0 Analysing the Structure ...........................................................................................................71
3.1 Pre-Analysis .................................................................................................................................................................... 73
3.1.1 Exercise Aims ............................................................................................................................................................... 73
3.1.2 Pre-Analysis Tab - Parameters, Loading and Materials ............................................................................................... 73
3.1.3 Model Options Tab – Model Analysis Settings ............................................................................................................ 80
3.2 Performing the Analysis .................................................................................................................................................. 82
3.2.1 Checking the notional lateral loads ............................................................................................................................. 84
3.3 Post-Analysis ................................................................................................................................................................... 86
3.3.1 Cross Checking the Analysis Result .............................................................................................................................. 86
3.3.2 Model and Analysis Results Display ............................................................................................................................. 88
3.3.3 Analysis Output Reports (for information only) .......................................................................................................... 92
4.0 Beam Reinforcement ..............................................................................................................97
4.1 Beam Reinforcement Design .......................................................................................................................................... 99
4.1.1 Exercise Aims ............................................................................................................................................................... 99
4.1.2 Beam Design Settings and Parameters ........................................................................................................................ 99
4.2 Designing all Beams using Batch Mode .......................................................................................................................... 99
4.2.1 Graphical Review of Passing / Failing Members ........................................................................................................ 101
4.3 Interactive Beam Design ............................................................................................................................................... 102
4.3.1 Utilisation Ratios ........................................................................................................................................................ 102
4.3.2 The Axis and Beam Information Editor ...................................................................................................................... 103
4.3.3 The Reinforcement Data Screen ................................................................................................................................ 104
4.3.4 Beam Detail Drawings ................................................................................................................................................ 104
4.3.5 Standard Bar Patterns ................................................................................................................................................ 105
4.3.6 Modifying the Number and Size of Bars .................................................................................................................... 106
4.3.7 Bar Layers................................................................................................................................................................... 106
4.3.8 Modifying bar curtailment ......................................................................................................................................... 108
4.3.9 Beam Loading and Force Diagrams ............................................................................................................................ 108
4.4 Creating the Beam Elevation Drawings ........................................................................................................................ 110
2012 Version 17
April 2
4.4.1 Putting All Beams onto a Single Sheet Automatically ................................................................................................ 110
5.0 Column and Wall Reinforcement........................................................................................... 111
5.1 Column &b Wall Reinforcement Design ....................................................................................................................... 113
5.1.1 Exercise Aims ............................................................................................................................................................. 113
5.1.2 Column Design Settings and Parameters ................................................................................................................... 113
5.2 Designing all Columns using Batch Mode ..................................................................................................................... 113
5.2.1 Creating a Column Schedule ...................................................................................................................................... 115
5.2.2 Creating a Column Output Report ............................................................................................................................. 116
5.2.3 Creating a Foundation Loads Report .......................................................................................................................... 118
5.3 Interactive Column Design ............................................................................................................................................ 119
5.3.1 Exercise Aims ............................................................................................................................................................. 119
5.3.2 Understanding the Column Design Editor.................................................................................................................. 119
5.3.3 Designing Rectangular Column .................................................................................................................................. 121
5.3.4 Column Slenderness ................................................................................................................................................... 123
5.3.5 Column Interaction Diagrams .................................................................................................................................... 124
5.3.6 Fixing the Bar Layout .................................................................................................................................................. 125
5.3.7 Link Arrangement ....................................................................................................................................................... 126
5.3.8 Shear Design............................................................................................................................................................... 127
5.3.9 Biaxial bending vs. BS 8.1.1.0-Cl 3.8.4.5 design ......................................................................................................... 127
5.4 Designing a Wall............................................................................................................................................................ 128
6.0 Slab Design ........................................................................................................................... 133
6.1 Slab Design and Detailing.............................................................................................................................................. 135
6.1.1 Exercise Aims ............................................................................................................................................................. 135
6.1.2 Slab Design Settings ................................................................................................................................................... 135
6.1.3 Member and Steel Bar Label Templates (Additional Info. Only)................................................................................ 136
6.2 Create Slab Reinforcement Strips ................................................................................................................................. 137
6.2.1 Filtering the Display of Slab Reinforcement (for information only) ........................................................................... 139
6.3 Editing the Bar Layout .................................................................................................................................................... 139
6.4 Creating Slab Output..................................................................................................................................................... 141
6.4.1 Output for an Individual Slab Strip ............................................................................................................................. 141
6.4.2 Creating a Slab Output Report for the Entire Floor.................................................................................................... 141
6.4.3 Table of Quantities ..................................................................................................................................................... 142
7.0 Flat Slabs .............................................................................................................................. 143
7.1 Flat slabs ....................................................................................................................................................................... 145
7.1.1 Exercise Aims ............................................................................................................................................................. 145
7.2 Creating the Flat Slabs in the Model ............................................................................................................................. 145
7.2.1 Inserting the Slabs ...................................................................................................................................................... 146
7.3 Creating Slab Loads and Openings ................................................................................................................................ 148
7.3.1 Slab Loads................................................................................................................................................................... 148
7.3.2 Slab Openings ............................................................................................................................................................. 150
7.4 Creating Additional Storeys .......................................................................................................................................... 151
7.4.1 Storey Information ..................................................................................................................................................... 151
8.0 Building Analysis for Flat Slab ............................................................................................... 153
8.1 Building Analysis for Flat Slabs ...................................................................................................................................... 155
8.1.1 Exercise Aims ............................................................................................................................................................. 155
8.1.2 Model Options Settings .............................................................................................................................................. 155
8.1.3 Pre-Analysis – Building Model Check ......................................................................................................................... 156
8.2 Performing the Analysis ................................................................................................................................................ 157
2012 Version 17
April 3
8.2.1 Building Analysis ........................................................................................................................................................ 157
8.2.2 Checking the notional horizontal forces .................................................................................................................... 158
8.3 Post-Analysis ................................................................................................................................................................. 159
8.3.1 Cross Checking the Analysis Result ............................................................................................................................ 159
8.3.2 Model and Analysis Results Display ........................................................................................................................... 160
9.0 Load Chase Down.................................................................................................................. 163
9.1 Gravity Load Chase Down Using FE Analysis ................................................................................................................ 165
9.1.1 Exercise Aims ............................................................................................................................................................. 165
9.1.2 Finite Element Model Generation Options ................................................................................................................ 165
9.2 Generating/Performing the FE Analysis Model ............................................................................................................ 169
9.2.1 Creating the FE mesh for Analysis.............................................................................................................................. 169
9.2.2 Performing the Batch FE Load Chase Down............................................................................................................... 171
9.3 Cross checking the Finite Element Results ................................................................................................................... 175
10.0 Flat Slab ................................................................................................................................ 177
10.1 Designing the Flat Slab ................................................................................................................................................. 179
10.1.1 Exercise Aims ............................................................................................................................................................. 179
10.1.2 Finite Element – Post Processing Settings ................................................................................................................. 179
10.2 Floor Analysis Post Processing ...................................................................................................................................... 180
10.2.1 Deflection Plots .......................................................................................................................................................... 180
10.2.2 Loading and Effects Toolbars ..................................................................................................................................... 181
10.2.3 Loading and Effects .................................................................................................................................................... 182
10.2.4 Setting the Concrete Effective Depth ........................................................................................................................ 184
10.2.5 Bottom Steel Reinforcement Provision ..................................................................................................................... 185
10.2.6 Creating the User Defined Contours (bottom steel) .................................................................................................. 186
10.2.7 Creating the User Defined Contours (top steel) ........................................................................................................ 187
10.3 Exporting and Displaying Contours ............................................................................................................................... 189
10.4 Exporting to DXF (for information) ............................................................................................................................... 190
10.5 Designing the Columns/Walls ....................................................................................................................................... 191
11.0 Appendix A ........................................................................................................................... 193
11.1 Wind Loads ................................................................................................................................................................... 195
11.1.1 Specifying Wind Combinations .................................................................................................................................. 195
11.1.2 Applying a Single Wind Load to Each Floor ................................................................................................................ 196
11.1.3 Applying Wind Loads directly to Columns & Walls .................................................................................................... 200
12.0 Appendix B ........................................................................................................................... 203
12.1 Beam Design Settings and Detailing ............................................................................................................................. 205
12.1.1 The Design Tab ........................................................................................................................................................... 205
12.1.2 The Parameters Tab ................................................................................................................................................... 206
12.1.3 The Bar Selection Tab ................................................................................................................................................ 206
12.1.4 The Curtailment Tab .................................................................................................................................................. 208
12.1.5 The Detailing Tab ....................................................................................................................................................... 209
12.1.6 The Layers Tab ........................................................................................................................................................... 210
12.1.7 Manually Creating Drawing Sheets ............................................................................................................................ 210
13.0 Appendix C ........................................................................................................................... 213
13.1 Column Design Settings and Detailing .......................................................................................................................... 215
13.1.1 The Design Tab ........................................................................................................................................................... 215
13.1.2 The Steel Bars Tab ...................................................................................................................................................... 216
13.1.3 The Detail Drawings Tab ............................................................................................................................................ 219
13.1.4 To Rationalise the Steel Bars in Individual Columns .................................................................................................. 221
2012 Version 17
April 4
13.2 To Rationalise the Steel Bars in Multiple Columns ....................................................................................................... 222
13.3 Creating the Column Detail Drawings ........................................................................................................................... 223
14.0 Appendix D ........................................................................................................................... 227
14.1 Foundation Design ........................................................................................................................................................ 229
14.1.1 Introduction ............................................................................................................................................................... 229
14.1.2 Foundation Design Settings ....................................................................................................................................... 229
14.1.3 Choice of Loading Method ......................................................................................................................................... 230
14.2 Pad Footings.................................................................................................................................................................. 230
14.2.1 Pad footing design...................................................................................................................................................... 230
14.2.2 Pad Footing Details .................................................................................................................................................... 233
14.3 Strip Footings ................................................................................................................................................................ 235
14.3.1 Strip Footing Design ................................................................................................................................................... 235
14.3.2 Designing the Foundation Beam ................................................................................................................................ 238
14.4 Raft Foundation Design ................................................................................................................................................ 240
15.0 Appendix E ........................................................................................................................... 243
15.1 Load Combinations and the Loading Generator ........................................................................................................... 245
15.1.1 The Loading Generator .............................................................................................................................................. 245
16.0 Appendix F ........................................................................................................................... 251
16.1 Report Manager ............................................................................................................................................................ 253
16.1.1 Concrete and Form Estimation Reports ..................................................................................................................... 253
16.1.2 Report Manager ......................................................................................................................................................... 254
17.0 Appendix G ........................................................................................................................... 255
17.1 Polyline Column Editor ................................................................................................................................................. 257
17.1.1 Creating an L-shaped column. .................................................................................................................................... 257
18.0 Appendix H ........................................................................................................................... 261
18.1 Slab Design using FE Analysis ........................................................................................................................................ 263
18.1.1 Introduction ............................................................................................................................................................... 263
18.1.2 Creating FE Slab Strips ................................................................................................................................................ 263
18.1.3 Finite Element Model Generation .............................................................................................................................. 265
18.1.4 FE Analysis Post Processing ........................................................................................................................................ 266
18.1.5 Updating the FE Strips with Reinforcement ............................................................................................................... 269
19.0 Appendix I ............................................................................................................................ 271
19.1 Enhancing the General Arrangement Drawings ........................................................................................................... 273
19.1.1 Exercise Aims ............................................................................................................................................................. 273
19.1.2 Dimensioning the Grid Spacing .................................................................................................................................. 273
19.1.3 Dimensioning up the Cantilever Slabs........................................................................................................................ 276
19.1.4 Shrinking Axes and Setting Unused Axes to Ghost .................................................................................................... 277
19.1.5 Creating Slab Section Views ....................................................................................................................................... 278
20.0 Appendix J ............................................................................................................................ 281
20.1 Orion Data File Structure and Project Settings ............................................................................................................. 283
20.1.1 Project Settings .......................................................................................................................................................... 284
2012 Version 17
April 5
Introduction
Background
1.0 Introduction
1.1 Background
Orion is developed for the analysis, design and drafting of Concrete Building Stuctures. Unlike general purpose structural
analysis programs, Orion is concentrated on accurate analysis, fast data preparation, automated reinforced concrete design
and automated preparation of engineering drawings and details.
Building systems have the following common structural features:
Geometry of a building system generally formed principly by horizontal beams and vertical columns.
Most of the time, the column and beam elements have similar cross-sections so that standard section types can be formed.
The in-plane stiffness of the floor slabs is considered to be high, forming rigid diaphragms at each floor level.
Applied loads are either in vertical (dead and imposed loads) or horizontal (wind, soil pressure or earthquake) directions.
There will often be repetition (in whole or in part) of floor layouts from one level to the next.
General arrangement drawings (GA’s) are somewhat stylised, but given the constrained area of application outlined above,
the system allows the model to be described by the development of GA drawings at each floor level. Even that process is
further simplified since beams etc are dealt with as coherant objects, not just lines. The more simplistic centre line analysis
model is automatically created in background at the same time. For example, in reality, 300 wide beams and 400 square
columns along an external elevation may be arranged with the outside faces flush which would mean that their true centre
lines are not aligned. It would be common practice to ignore this degree of mis-alignment for analysis purposes. Orion will
not un-necessarily complicate the analysis model.
In addition – different preferences can be held and automatically used for analysis and design purposes. For example, beam
flanges can be ignored in the analysis but then utilised for reinforcement design (sagging moments only) without any re-
modelling.
In summary, an Orion model allows you to
Create GA drawings
Design the Floor Slabs, and de-compose floor loads onto beams.
Analyse the building frame
Design continuous beams, columns. walls, and foundations (pad, strip and raft)
Automatically generate RC detail drawings.
Note that analysis and design results are represented so that the reports look like a "Building Output" by classifying the
members as columns, walls, slabs and beams with the same notations used in the floor plans.
Structure Members
Tree Toolbar
NO
To select a second, and further, object(s) you can press the CTRL key while picking entities successively. If a selected element
is picked again, then it will be de-selected.
Window/Crossing Selections
After clicking on the "Pick" icon from the Members Toolbar, multiple elements can be selected by enclosing them in a
selection window. A selection window is a rectangular area that is defined in the drawing area by dragging two opposite
corners.
Two types of window selection are available. "Select Entity (Window)" option selects entities that are entirely within the
selection area. "Select Entity (Crossing)" option select entities within and entities crossing the edges of the selection area.
"Select Entity (Window)" is performed by clicking and dragging from left to right as shown below.
nd
2 Point
st
1 Point
Fence Selection
Fence is a line that selects all entities that it crosses.
To perform "Select Entity (Fence)" hold down the SHIFT key and drag a line that crosses all elements that are intended for
the selection set.
This option is useful when a set of non-orthogonal entities are to be selected.
nd
2 Point
st
1 Point
The same process applies to all element types. You can edit multiple beams/columns/walls etc by selecting the elements you
need to edit and following the same steps as above. You can edit all elements of a particular element type by using the
member tables from the “Member” drop down menu.
2. Right mouse click and choose “Delete” from the context menu.
2. Press the "Delete" button on your keyboard or right mouse click and choose
“Delete”
4. Click “OK”
This will just delete the selected slabs and will leave all other selected elements in the
model.
Regen
The "Regen" command re-generates all drawing entities using stored geometry information. This command is slightly time
consuming than the redraw function.
Zoom Window
You can quickly zoom in on an area by picking the opposite corners of the zoom window defining it.
After selecting the "Zoom Window" option, specify the opposite corners of the zoom window in the drawing area by dragging
two points.
Zoom Previous
All zoom operations are stored. So, anytime, a previous display can be recalled using the "Zoom Previous" option.
Zoom Extents
"Zoom Extents" displays a view that includes all objects in the current storey at the highest magnification that will fit in the
drawing area.
Zoom Limits
"Zoom Limits" displays a view that includes all objects contained within the active sheet borders at the highest magnification
that will fit in the drawing area.
Pan
After selecting the "Pan" option, you can pan the drawing image to a new location by left clicking and dragging from one
point to another.
This function can also be achieved by depressing the scroll wheel on your mouse and then moving the cursor around the
screen.
"Zoom In (20%)" increases the magnification of the current view by 20% and "Zoom Out (20%)" decreases the magnification
by a similar amount. This option can be used to quickly zoom in and out to the centre of the current view.
This function can also be achieved by using the scroll wheel on your mouse. The Zoom will be focussed on wherever the
cursor is placed on the screen.
Modelling Fundamentals
The object of this exercise is to familiarise you on how to start a new project in Orion and how to input some basic project
parameters.
Enter a Project Code. Type the code as shown using the ‘_’ character to denote spaces.
Then Click OK
This will automatically create a folder called Training_Course_Model_1 beneath the default data folder shown on the
previous page. This will be used for storing all the model data.
Note: For the purposes of this course, we will just select one of the default templates. For more information on how to
create and edit templates and how to fully utilise the Settings Centre, please refer to the Orion Help document from
under the Help menu.
Click on the drop down arrow to see the various sheet sizes available, pick A0 then click OK.
Note: You can enter your own sheet size in the width and height box if your required size is not available. You can also
change the drawing and detail scales from this dialog.
Note: The sheet origin (0,0) is located at the lower left corner of the drawing sheet. If after creating your model, you find
it is too close to the edge of the sheet, you can reposition it by clicking on the Sheet Origin button.
Enter the storey height as 3300mm as shown below then click OK.
st
After entering the 1 storey height, the main drawing area (Graphical Editor) appears.
Orion is now fully open and ready for our model to be created.
Note the text that is displayed at the bottom of the screen. This is prompting you how to proceed.
Hold down the Ctrl key while picking a point in the lower left hand region of the drawing sheet.
After picking the reference point the Orthogonal Axis Generator screen should appear.
Note: You could now click on the screen to define the co-ordinates of the reference point, however to ensure it has a
sensible (i.e. whole number) offset from the origin hold down the Ctrl key on your keyboard while picking a reference
point.
Note: The Orthogonal Axis Generator will create Direction 1 axes horizontally and give them Alphabetical labels,
Direction 2 axes will be created vertically with numeric labels. It is worthwhile maintaining a convention so that the same
axis directions are applied in all models. We would suggest all axes within +/- 45 degrees of the horizontal be assigned
direction 1 and all axes within +/- 45 degrees of the vertical be assigned direction 2.
X axis (0 degrees)
From the Edit menu choose Object Snap Settings and ensure the
Intersection, EndPoint and MidPoint Osnaps are switched on. Then
click on OK.
The Osnaps you have specified become active when using either the Axis or
Dimension commands.
To select several axes at the same time hold down the Ctrl key whilst picking the axes. The solid blue line indicates the last
axis selected, the other axes that have been selected can be identified by the small squares or grips that appear at the ends
of the axes.
The selected axes are also indicated in the Structure Tree View. Clicking on the axis label in the tree view also selects an axis.
Holding down the Ctrl button whilst clicking in the Tree View, also allows the selection of multiple axes.
With this axis selected, right click to activate the context sensitive pop up menu as shown.
Note: The commands available on the pop-up menu will vary depending on what is selected.
The pop up menu allows the selected axis to be edited in a number of ways.
Pick the base of rotation by clicking on the intersection of axis A and 5. Provided you have set up Osnaps,
the cursor should snap to the exact intersection.
Repeat this procedure to rotate axis F by 10 degrees about the intersection of axes F and 1.
From the Edit menu choose Select Entity (Fence) and then drag a line between Axis E & F through all the
vertical axes so they are all selected.
Right mouse click to bring up the pop-up menu and pick Stretch Axis
Click and Hold with your left mouse button near Axis 6 and drag up past Axis F.
Either;
1. Create a new line parallel to an existing axis. To do this, select an existing grid line then right click to activate the
context sensitive pop up menu. Choose Offset Axis. Define the offset and the label for the new axis and then left
mouse click to one side of the initially selected axis to indicate the side where the new axis is to be drawn.
2. Create a new line by using the Axis Tool. To do this, select the Axis Tool from the Members Toolbar.
Define the new label, then left click and drag to draw the axis. Note that using this method the line is
being drawn ‘free-hand’ making it difficult to draw the line to an exact angle or length. To rectify this, hold
down the CTRL key when drawing the line. This forces the angle and length to snap to multiples of the
values shown in the Graphic Editor View Settings – Plan Tab.
With an Angle Step of 15 deg and a Length Step of 1000, holding down CTRL will force the axis to snap to an angle of
0,15, or 30 degrees etc. and a length which will be a multiple of 1000mm.
The Column Properties dialog should appear as shown. There are 4 tabs to this dialog.
Dir 1/2 button - Indicates the column faces are parallel to which directions (axis). This will be demonstrated within the next
few pages. (Pay attention to the column at grid B / 5)
- Column end conditions options (Fixed / Hinged). Simply click on the button to toggle the end conditions. Note pinned
joints in concrete structures should be used with caution.
b1 = width of drop
b2 = length of drop
e1 and e2 = allow the drop to be offset
h-Head = depth of the drop from the top of the slab
Support Types > [Default]. The Default support condition is defined in Member > Support Type Definitions. The user can
define additional support conditions for translation / rotation in the x, y and z axis.
(mm) del z (top/bot) – The user can define different top and bottom levels for each column relative to the datum, i.e. for a
sloping site.
Plane (top/bot) – If a column/wall has been assigned to a Plane (i.e. for a sloping floor) then this Plane is referenced and the
appropriate del z setting is made inactive.
st
The 1 column we will create will be of size 600x300 where 600 will be in direction 1. Also these columns are to be parallel to
the grids in both directions 1 and 2.
Click the Dir 1/2 button to indicate the column faces are parallel to both directions 1 and 2.
Note: By right clicking on these boxes we can select a dimension from those available instead of typing a value.
Click the centrally placed column icon from the Insertion Options to update the e1 and e2 values as shown to the
right.
Label Corner - Allows the user to define the label position relative to its four corners.
Place the cursor over Grid 1 and Grid B intersection (Note that the axes become highlighted in grey to show which
intersection is being used) and left click to insert the column.
Click on the Zoom Window icon or from the Main Menu bar pick View/Zoom Window
Then box around the Grids A-B/1-3 to see the inserted column.
Note: The circular symbol labelled with an “R” indicates the centre of rigidity of the floor plan. As there is currently only
one column on this floor the centre of rigidity is at the centre of the column.
Click the Zoom Limits icon to see the limits of the drawing sheet.
Now enter another column of the same size at Grids B/2 by positioning the cursor at this grid intersection and left
click the mouse.
Do this along the Grids B/4 –5, so your screen should look as shown.
Note: The column at Grid B/5 is drawn as a parallelogram and is placed parallel to both the grids it is inserted at because the
Dir: [1/2] button was selected. If only Dir: [1] button was selected then the column would be drawn as a rectangle, only
parallel to the grid in direction 1. The reverse applies if the Dir: [2] button is selected.
Now enter the rest of the centrally placed 600x300 columns at the following Grid Intersections: D/1, D/4, D/5, E/4 &
F/5.
Now with the properties for the 600x300 column active, use the
Insertion Options to align the column so that its top left corner is
positioned flush with the grids. With the alignment as shown, the
eccentricities should change to e1=0 and e2=300.
Members can be ‘nudged’ into their final position using the keyboard cursor keys.
Using the cursor keys ‘nudge’ column 1C10 to an eccentricity of e1 = 150mm, e2 = 175mm. (Alternatively type these
eccentricities into the Column Properties dialog and click Update.)
Note: The size of step can be controlled via Settings > General Settings, by adjusting the Member Section Eccentricity
Step on the View tab.
Use the Insertion Options again to align the next column thus so that its right edge is flush with the grid
line. Ensure that Dir: [1/2] is selected and then insert the column at Grid Intersection E/5.
Now enter some square columns of size 350x350 centrally placed at grids and parallel to axis in direction 1 only.
These columns are to be placed at Grids E/1, E/2 & F/3 as shown below.
Type 400 in the b1 box and leave b2, e1 & e2 as 0, then click on Grid F/4 to
enter the circular column.
Note: To enter a void in the centre of the column, put a negative value in
the b2 box (i.e. 100mm pipe would be entered as -100).
All the columns have now been entered. They should be shown positioned at the grid line intersections below:
st
1 Storey Column Layout
Take a look at the Structure Tree - If your model is correct it should be indicating 15 columns at this
stage.
Ext I Ext J
(mm) del z (I,bot) – The base levels of ends I can be controlled based
off the datum.
(mm) del z (J,bot) – The base levels of ends J can be controlled based
off the datum.
Wall Model Type –The analytical model for this shear wall can be
controlled on an individual basis. The Mid-Pier and FE Shell Methods
are described fully in the Engineers Handbook.
FE Shell Model
Pick the Shear Wall icon or go to Member/Shear Wall from the Menu bar.
Enter 200 in the b: dimension box, 100 in the b2 box and enter 100 in the Ext: I & J boxes. (This is how far
the wall extends past the grids that it is inserted).
Click on the Insertion Options icon and select the wall to be centrally placed on the grid
Insert the wall by clicking and dragging from the start grid C/2 to C/3.
Do the same at Grid D/2 to D/3 and Grid C/2 to D/2 as shown below.
We will first enter some Beams along Grid B/1-6 of size 300x600.
In the Beam Status Bar ensure that dimension b is 300 and the dimension h-bot is 600.
Pinned – Left clicking on the blue beam allows the user to define
pinned end supports, on either / both ends of the beam
h-bot – This is the amount you wish for the beam to project below
the slab.
H-top – This is the amount you wish for the beam to project above
the slab.
The beam along Grid B/1-6 is to be placed in the centre of Grid B so that the b2 dimension is half of the b dimension,
Ensure this by clicking on the icon this will automatically set the b2 dimension to 150mm as shown above left.
The beam is positioned at Grid B/1-6 by left clicking and dragging from the start of Grid B/1 and releasing when your
cursor is at Grid B/6 so that 4 beams are entered as shown below.
Note:
Like the columns, the beams are automatically labelled based on the storey and numbered sequentially as they are
entered.
Orion has automatically split the beam into four individual members between the columns.
Now enter some more beams in the following order of same size at the following locations:
Note: A beam will not be placed where a wall already exists. A beam was not placed at Grid D/2-3 because of this.
The perimeter beams along the top and bottom edges are only 250mm wide and 800 deep. Enter them as indicated
in the table below ensuring they are placed centrally on the grid:
A *** Slender Section*** warning message should appear, click on OK to accept and your screen should look as
follows.
Note: The perimeter beam at Grid A/1-5 has been created as a single beam spanning > 17m and supporting the vertical
beams along grids 2 and 4. It is possible to redefine this part of the model so that the beams along grids 2 and 4 become
cantilevers that support the perimeter beam.
Delete the perimeter beam along the bottom edge and then re-enter it as 3 separate beams as indicated in the table
below:
Note: When you place the beams between C/3 and C/5 you will see a message about sub-dividing these beams with the
beam running along axis 4 – Click Yes to sub-divide
Hint:
Have you missed out any
of the beams?
Take a look at the
Structure Tree - It should
indicate 37 beams.
st
1 Storey Beam Layout
st
We will now enter the slabs at the 1 storey.
In the Slab Properties enter the slab thickness h to be 120 and the cover to be 25, all dimensions are in mm.
2
Then click on the Loads tab and enter an Additional Dead Load of 1.2kN/m and in the Imp. Load box do a right
2
mouse click and select a value of 1.5kN/m .
st
Enter the 1 slab by positioning the cursor between Grid A-B/1-2, then left click the mouse.
st
Your 1 slab 1S1 should appear as below including the yield line for the slab load distribution.
Repeat this process to define two more 120 thick slabs as follows:
Now enter some 150 thk slabs which have the same Additional Dead Load as the existing ones but are to have an
2
Imp. Load of 3kN/m
Clear any members that are currently selected by clicking on the Clear Selection Set icon
Right mouse click on the Slabs folder in the Structure Tree and select Set Slab Types Automatically as shown below
Click on OK to proceed
Enter the length of the cantilever slab to be 1000 in the L-Cant box, so your
properties window should look as shown to the right.
If you click on the Display Slab Label icon so a cross goes through it.
The effect of this is to switch off the label for the slab on the drawing.
As with normal slabs, click on the Loads tab. Ensure the Load values are as
2
follows: Dead Load 1.2 kN/m, Imp. Load 3kN/m
You could now insert a cantilever slab along the full length of a beam in the
same way as you would insert a beam or wall
Tip: Click along the RHS of the beam. When clicking from intersection to intersection
click in an anticlockwise direction.
Note - Each cantilever slab can only be defined relative to one beam. Therefore, to place a cantilever slab along the side
of a building, you would be required to specify separate slabs for each of the beams along the edge. Also the insertion
points for the beginning and end points of the slab should coincide with those of the beam to which it is adjacent.
With the cantilever slab properties still active, type the slab width in the b-slab box as 3000
In the ‘d’ box, type the distance from the grid where the slab is to be inserted as 4000. The slab thickness, h, is 150
Now click and drag from Grid 3/F to 1/F so the cantilever slab 1S16 is shown as below
So you can see from this that b-slab controls the width of the cantilever and d controls how far from the start insertion
point the cantilever slab is positioned. This then allows you to control the size of the cantilever slabs easily.
This allows a step in the slab, however if the relative difference in elevations will cause a separation in diaphragms, then try
using plane definitions.
It is possible to set up some default Slab Additional Loads by going to Member > Slab Additional Loads Library. This allows
you to set what materials are being used for a particular slab area and automatically works out the load this would impart.
These can then be saved and quickly applied as Additional Slab Loads using the drop down menu on the Loads tab in the Slab
Properties window.
This will re-label all elements in the plan view, but they will still be listed in the same order as they were created in the
structure tree. To have them listed numerically again – i.e. 1C1, 1C2, 1C3 etc – you will need to save the model and re-open
it.
Clear any previous selections by clicking on the Clear Selection Set icon
This same option is available from Member > Member Tables > Slab Table.
The Slab Table should now appear as shown, containing all of the slabs. From here it is possible to change either the property
of an individual member in the table or update a property of all the members at the same time.
Highlight the column, h as shown by clicking on the label at the top of the column.
Without clicking anywhere else, type the new required slab thickness, 200mm
Press Enter and the new thickness have been auto-applied to all the slabs in the table.
Note: When the slab thickness is changed the self weight is also automatically modified.
Click on one of the other rows in the table to move the focus off 1S16 as shown
Click on Close
Note: If several members of different element types are selected, you will not be able to right click and
choose Properties. Instead you should right click and choose the required Member Table. For example, if
you have some, but not all, slabs selected and then either open the Slab Member Table or right click and
choose Properties, the member table will be opened and only the selected slabs will be listed. This would
allow you to edit multiple elements in one go without editing all.
Alternatively you can have the Member Tables toolbar docked permanently on screen - This can be done by
right clicking on any toolbar to display the menu of available toolbars. Tick the Member Tables toolbar option
and it will be displayed and can be dragged to a suitable position.
Note: Slab loads will be automatically applied to beams based on the default Slab Loads Calculation Method. For this
example, this is currently set as the Yield Line Method.
Select the beam at the right end of grid F, right click and choose Edit Beam Wall Load
Click on OK and the beam is shown hatched, indicating it has a Brick Wall
load applied
To apply the same wall load to the other perimeter beams proceed as follows:
Right mouse click on the same beam again and this time choose Copy Beam Wall Load
Using the Pick icon, select the remaining perimeter beams, remembering to keep the CTRL key held while selecting, so
that each one is added to the existing selection set
When the entire perimeter beams are selected, right click again and this time, choose Paste Copied Beam Loads from
the menu
When prompted by the below message, click Yes to apply the beam wall load to the beams
Right mouse click to display the Pop Up menu and choose Edit Member Loads
The existing loads on the beam are displayed. T2 and T1 are the slab loads from left and right. The self weight of the beam is
also displayed.
Note: This is the chosen Load decomposition method for this beam [Default].
The three icons at the top of the Load Profile Editor allow you to
add Uniformly Distributed Loads, Partially Distributed Loads and
Point Loads respectively.
Click on OK
Click on OK
To view the ‘Total Added Loads’ on the beams in the plan view, go
to Settings > View Settings and click on the Beams tab
This will now display the Total Added Loads in the plan view next to every
beam, as shown in the image at the bottom of this page.
You will notice that the settings to control the Beam Hatching are
also found in this view
Try switching between Beams With Wall Loading (to hatch the
perimeter beams) and Beams With User Defined Loading to
hatch beam 1B30.
Click on OK
A 3D view of the model can be obtained which will allow you to choose different layouts of Plan view (P) and 3D view (3)
windows. It is possible to create different 3D views in different windows.
Note: Alternatively, the Plan/3D View tab at the bottom of the screen can be used to cascade & tile the different windows
Zoom - Scroll the scroll wheel on your mouse and will zoom in to the centre of the model.
Pan - Depress the scroll wheel on your mouse and then moving the cursor around the screen.
Rotate - Hold down the right mouse button and moving the cursor around the screen. The model will rotate about its centre
point.
There is also a toolbar at the bottom of the 3D view that allows much more manipulation of the view.
Plan Settings Window Zoom
View Views Functions
You can also model in 3D by being able to Insert, Edit and Delete elements in the same manner as in the 2D view.
Right click on Storeys in the Structure Tree to display the Storey Menu
Right click on Storeys in the Structure Tree to display the Storey Menu and
select the option Generate storey (or go to Building > Generate Storey) so
the Generate Storey window appears
Highlight St01 as the Source Storey and then St04 as the Target Storey.
Once you get the message ‘Process Completed’ at the bottom of this window,
select Close
From the Structure Tree you will see that St01 & St04 have a circle mark next to them but St02 & St03 don’t have this mark.
Floors with a mark are classed as ‘Unique’ and have their own storey information (beams,
columns, walls etc). Floors without a mark next to them are classed as ‘Duplicates’ and are
automatically made identical to the first Unique Storey directly above it. Therefore, only
‘Unique’ storeys can be edited. Hence storeys St02 & St03 are duplicates of St04. This is
highlighted by the Storey Reference in brackets.
Whatever changes are made to the Unique Floor will be carried through its Duplicates.
Therefore, if we were to edit St04 now, the same changes would be applied to the Duplicates St03 and St02.
We want to edit St04 (the roof) but keep the other floors below it the same as they are now. Therefore, we need to first
th
generate the same storey information from the St04 to St03 then modify the 4 storey accordingly.
Right click on Storeys in the Structure Tree to display the Storey Menu and select the option Generate storey.
Ensure that the source storey is St04 and the Target Storey St03 then choose OK
From the Structure Tree you will see that St03 now has a circle mark next to it indicating that
it is a unique and editable floor, as are St01 and St04.
St02 cannot be edited, as it is identical to St03.
If you are not currently viewing storey 4, double click on Storey: St04 so that it is shown in bold (as shown on the
right)
Select the Slab Type to be 1 and ensure the thickness is 200mm and the cover 25mm.
Then enter the slab where the lift wall is at Grid 2-3/C-D
Select Edit Storey from the storey menu or by going to Building > Edit Storey so the Edit Storey dialog box appears as
shown below.
To change a floor height, click in the cell for h(mm) at the desired storey, St01
Change the current value of 3300 to be 4000. Click outside the cell and you should notice the values in the Level
column have changed as shown below.
st
1 Storey Bottom Level – This is effectively the Z co-ordinate for ST00. This does not affect the storey heights of any level
and is only used to calculate the reference level for each floor (shown in the ‘Level’ column in the table above).
Foundation Level –This is the length of the column below the datum level (St00), by Default 1100m
Click OK
Building Analysis
3.1 Pre-Analysis
3.1.1 Exercise Aims
Set up the Project Parameters and Loading and selecting the Materials
Define the Analysis Settings
As you can see, the Pre-Analysis Tab allows you to set up the Project Parameters, edit the Loading and Load Combinations
and select your Materials. These features will be discussed in more detail but the trainer, but are also covered extensively in
the Orion Help System.
The Parameters button allows the user to set/modify the Project Parameters. These include:
Lateral Loading: Decide how your Notional Horizontal Forces are calculated
The Edit Load Combinations button can be used to view and, if required, modify the load combinations and their factors.
You can view/create/edit individual Load Cases by clicking on the Load Cases button, or get Orion to automatically create
Load Cases and Combinations by pressing Loading Generator. For more information on this, please refer to Appendix E of
this manual or the Engineers Handbook.
The Edit Storey Loads button can be used to view and, if required, modify the lateral load cases applied at each storey. You
can also view the Mass and co-ordinates for the Centre of Gravity for each level. The notional lateral loads are calculated
automatically once the Building Analysis is complete.
The Edit Materials button can be used to view the concrete and steel grades selected for each member group and the steel
bars available for the design for each element group. You can also specify the Unit Weight of Concrete and Blocks and set
the Coefficient of Thermal Expansion.
Click the Edit Materials button on the Pre-Analysis Tab so the following screen appears.
Click on the Concrete Grades button adjacent to Columns, choose Concrete Grade C32/40 and check the Apply to All
Members Types box as shown below and then click OK
This will set all structural members to have Grade C32/40 Concrete – 32 being the Cylinder Strength and 40 being the Cube
Strength.
Click on the Steel Grades button adjacent to Columns and then choose Grade 500 (Type 2) and check the Apply to
All Members Types box as shown below and then click OK
This will set all structural members to have Grade 500 (Type 2) Steel for their reinforcement.
Check that you have the unit weight of concrete set to 24kN/m3 before proceeding.
You will notice some bars have been selected by default. Bars can be unselected by clicking on them to remove the tick
(similarly click to select).
Note: If you do not select a particular bar size here, that size will NOT be available for selection in the design process
later. For example, if you only ticked H16 in this window, only H16s could be used to design the Columns later.
Make sure the selected bars are H10, H12, H16, H20, H25 and H32
Note: You may prefer to modify the bars to select from. Some bars are only available in Europe and others in Asia.
However, these training notes are based on the above bar sizes - if you make changes the member designs may differ
from the manual.
Click OK to go back to the materials tab, then review (and modify if desired) the bar diameters to be used for beams,
slabs etc.
The model options shown here are fully described in the Engineer’s Handbook, found from the Help Menu.
Automated generation of Rigid Zones (where beams frame in to columns/walls) is an advanced feature within Orion. Setting
Rigid Zones to Maximum, or Reduced by 25% creates a more realistic model of the beam/column interface which reduces the
design moments within the beams.
On this page, the engineer can globally adjust the properties to be used for each member type.
Note: The torsional stiffness factor has been set to 0.01 for the beams to prevent significant torsions from developing.
Total Hor. Drift Limit – This check is for the maximum total allowable displacement, which is checked at every storey level.
12000mm * 0.0010 = 12mm
Relative Hor. Drift Limit – This check is in accordance with BS 8110: Part 2 and is the maximum relative displacement
between each storey. 3300mm * 0.002 = 6.6mm
Note: For flat slab models there is an option to use undecomposed slab loads for the notional horizontal load calculation.
See later notes.
This will check that the building is valid for those conditions indicated.
Note: Even if this reports no errors, it doesn’t guarantee that the building is modelled correctly. There can be other problems
in the model that are not picked up by the validity checking process.
During the Building Analysis, the Beam Load Calculations (All Storeys) are completed (based upon your loading method –
currently Yield Line). The slab loads are distributed onto the supporting beams; all the load data is assessed; the weights and
mass centres of each storey are calculated and any notional lateral loads are determined.
After analysis it is then possible to automatically perform Column/Wall Reinforcement Design and Beam Reinforcement
Design for all members in the building.
Make sure Column/Wall Reinforcement Design and Beam Reinforcement Design are not checked before clicking on
Start to begin the building analysis process.
The Beam Load Calculations commence and a warning message should be displayed.
Click Yes and the analysis process continues and then OK when the Analysis has completed.
By clicking on each of the storey labels in the upper table, the Nx and Ny values for each storey can be viewed and edited if
required, in the lower table.
Point of Application
Nx CofG
CofG = Centre of Gravity
Ny
Floor Plan
17.333m
Sheet Origin
14.070m
(0,0)
3.3 Post-Analysis
3.3.1 Cross Checking the Analysis Result
An important cross check on the validity of the analysis is the Axial Load Comparison Report. This report sums all of the dead
and live loads applied at each storey and displays the axial forces in the columns and shear walls. These values should equate
to each other (within a few percent). If they do not the reason for the discrepancy should be investigated.
The total “SUM OF APPLIED LOADS (Using Un-Decomposed Slab Loads)” values should be similar to those from the
Decomposed Slab Loads table.
Provided that any difference between the un-decomposed and the decomposed values can be accounted for, the Total
Decomposed Applied Dead Load should be compared with the Total Delta G value from the “BUILDING ANALYSIS
COLUMN/WALL AXIAL LOADS” table. Similarly, the Total Decomposed Live Load should then be compared with the Total
Delta Q value.
Any significant differences in these values also have to be able to be accounted for.
If required the report can be printed, or it can be saved for later inclusion in a batch print out of all reports created by the
program.
Click on Save
See following page for an example of the Axial Load Comparison report
CHECK 1
CHECK 2
CHECK 3
The Analysis results can also be viewed graphically. Various effects can be displayed and the results can be filtered by axis
and by storey.
If too many labels are displayed the screen can appear cluttered as shown above. However, using the various drop-down
filter buttons and the view settings, you can create something more meaningful.
Click the various filter buttons to create different views. You can use the ribbons to choose what you want to show,
and then the button can be toggled on and off.
Above from the Elements ribbon we have selected the Nodal Points and the Frame Elements filters.
By clicking on the General Ribbon and selecting the Filters button, you can filter by storeys, axes and member type, as shown
above.
You can also do a Search for specific nodes, frame elements or shell elements by clicking on the binoculars icon, to the left of
the filters button, as shown below.
A large arrow will point at the item you have searched for. This is useful if the Building Analysis reports conditions with
certain nodes.
There are further filtering and setting options found in the View Settings window, situated on the left hand side of the
screen:
Below is a view of the model showing the displacement, using the Displacements filter from the Results Ribbon. The X values
have also been displayed, and the displacement scale has been increased.
This next view shows the frame loads and values for storey 4 only.
All results displayed are based on the specific Load Case or Load Combination selected in the Loading Window on the right
hand side of the scree drop down menu.
Expand Storey 1 and highlight Columns and Walls by holding down CTRL as shown
Click on the button to transfer all the columns and walls to the right hand side
Note: ‘i’ results are at the top of the members and ‘j’ results are at the bottom.
Click Next
Change the output options to match those shown on the following pages.
Note:
Y – This denotes a Loadcase
K – This denotes a Load Combination
Sign Convention
Positive Definition of Member
Forces
Click the Create Report button and a report should appear in WordPad as shown below.
Close the Report and then choose Exit to go back to the Analysis Form dialog box.
From the Analysis Form, a formatted version of the report could be generated by selecting “Structural Member Results” from
the Output Reports drop down menu. This could then be printed directly or saved to a file using the commands on the File
menu.
Apart from the Building Analysis Results, various other reports are also available.
This area allows you to export your Orion model to various other programs – such as S-Frame - so you can investigate it
further without having to create a new model for each program.
As we have seen, the analysis results report is available on the Post-Analysis tab, however all of the other detailed output
reports are available from here, For example:
Post Analysis Checks Report: - the horizontal displacement (drift) checks (Total and Relative).
Analysis Model Echo Report:- the full analysis input data file.
Storey Displacements Report: Orion calculates the displacements in the x and y directions and torsion for each load
combination for each storey.
Sway Classification Report: This report is based upon ACI code recommendations, and is not applicable if braced conditions
have been manually amended. This option should only be used with cross reference to the ACI code.
Each of these reports can be printed, or saved for later inclusion in a batch print out of all reports created by the program.
They can also be exported to a variety of different file formats.
A brief overview of the options will be given by your trainer, but for further information regarding these settings please
refer to the extensive Help system. The subsequent beam designs were undertaken with the Default Settings for the ‘UK
(BS8110)’ Template.
Go to Run > Beam Section Design and Detailing > Storey Beams
The Beam Design Settings can also be found in the Settings drop down menu in this window.
Design ribbon > Design Panel > Beam Reinforcement Design (Batch Mode).
You can review all of the designs and any errors by clicking the Messages button, which appears upon completion of the
batch design
The beams that have been successfully designed are now indicated in the table.
The batch design has been performed in accordance with the current beam design settings. These can be modified to suit the
users requirements.
If you re-run the building analysis after making any changes to the model and then go back into the beam design window, the
colour of the design ticks will have changed.
Close the beam design summary and click the Design Status tab as shown.
Select Run > Beam Section Design and Detailing > Storey Beams to redisplay the beam design summary.
If the utilization ratio is less than one but the beams are still failing this will probably be because:
The Axis and Beam Data window opens showing the beam dimensions and supports along axis F at storey 1.
Note: If the beam size is too small, changing the values displayed here can amend it. However, the Graphical Editor will
need to be updated manually also.
The Beam Ribbon > Interactive Design Icon shows design forces used to determine the required area of steel for the
highlighted beam. Six values are shown representing the factored left and right end moments and the mid span moments at
the top and the bottom of the beam. The left and right design shear force is shown also.
Note: The user can manually edit the above design forces by simply typing over the displayed values. If this is done the
Effects Manually Edited box would automatically become checked. If subsequently the box is unchecked, the values
would revert to those that had been calculated by the analysis.
Any figures in red indicate a problem. In this case there aren’t any problems. However, if the number of top span bars are
reduced for 1B18, a spacing issue is highlighted in red, as shown above. Settings that can be adjusted to try to obtain a
design include number of bars, bar diameter, lap lengths, cranks and layers. These will be discussed further in a short while.
Standard Pattern 2
Try this now to investigate the other bar arrangements, make use of the Beam Details button to see the differences between
each pattern.
Standard Pattern 1
Standard Pattern 3
Modify the bar layout for 1B18 to return the top bars to 3H16. This will change the spacing to 73mm, which is
greater than the minimum of 50mm but less than the maximum 140mm, as per the Beam Design Settings.
Alternatively you could amend the maximum bar spacing value in the Beam Design Settings.
Change the Top bar for 1B17 to 2H25 – insufficient steel is now provided for the support
Click beneath the Top Bar on 1B17, on the line for Sup.Top Bar
With these support bars still selected and click on the Bar Layer Tool to change to bars at layer 2 as shown below:
Click on the 2H16 Top Bars in 1B19 and change the right end for them by clicking on Extend Right to Short
The effect of this is shown as a shortfall in the required area of steel at the right hand end of the beam. As shown below.
Return to the original curtailment setting by changing back to Extend Right to Lap
Below are the Load, Shear and Moment diagrams for the Design Envelope. All load cases and combinations are also
available using the drop down arrow next to the Diagrams button.
Exit from the diagrams then click on OK to store the interactively designed bar arrangement for this axis.
Important Note: In the Reinforcement Data screen, if you click OK to store a beam while there is still a bar spacing
warning, the program interprets your action to mean that you have made an engineering decision to treat the current bar
spacing as acceptable. Provided the utilization ratio is less than 1.0 the beam would now be given a PASS status.
Click on All Storeys (Single Sheet) and OK to accept 1 beam axis across the width of the drawing sheet
All the beams are placed onto a single sheet and a table of quantities is created as shown below
The new CAD Productivity Booster is implemented for all drawings created in Orion, i.e. beam details, column details and
schedules, slab layout details etc. The DXF’s created are opened directly in the 3rd party cad editor or viewer of your choice;
this can be specified via the new CAD Editor tab on the General Settings dialog from the Settings Menu
A brief overview of the options will be given by your trainer, but for further information regarding these settings please
refer to the extensive Help system. The subsequent column designs were undertaken with the Default Settings from the
‘UK (BS8110)’ Template.
Choose Design Ribbon > Column Design ( Batch Mode) in Column Design Reinforcement window
Ensure your settings are as shown above, and then choose Design.
After the design is complete you could click on the Messages button to review the bars selected for each column for
each combination.
Then choose Close to take you back to the Column Reinforcement Design window.
The same ‘traffic light’ system used for the Column Design Status: Green Tick – Pass, Red Cross – Fail, Yellow Tick –
Results are not up to date for this element.
Note: A very low utilisation ratio can be displayed for some columns if the minimum steel is sufficient.
Choose some columns to be placed on the schedule as shown. (Hold the Ctrl key down while selecting).
Close the schedule and cancel to return to the Column Reinforcement Design window.
The columns to be included in the report are marked by a blue tick in the Print column. Columns can be added or removed
from the report using a combination of the icons Mark for Printing, (F7) Mark All Columns for Printing (Ctrl+F7) and Clear All
Print Marks (Shift+F7).
From the Design Ribbon > Reports Panel, choose Design Report.
The Report can be sent direct to a printer, or it can be saved for later inclusion in a batch print out of all reports created by
the program. It can also be saved in PDF format for sending to other computers on which the Orion program is not loaded.
Click on Save
Close the report and return to the Column Reinforcement Design window.
The ‘Column Reinforcement Design’ window can also be printed using the Print Column Report icon.
This report is created from within the Column Design Module. The report can consist of forces in all columns or only those at
foundation level.
From the Design Ribbon > Report Panel, choose Column Forces Listing.
A dialog appears as shown allowing the user to configure the report as required. The List button will create the report in
WordPad, from where it can then be printed.
Either Double click on the column, or choose from the Design Ribbon select the Interactive Design icon, so the
Column Design Editor is launched
Section:
Section dimensions include the dimensions of the column (“b1” and “b2”), the eccentricities (“e1” and “e2”), the column
clear lengths (“L1” and “L2”), and the concrete cover.
If you modify these fields, you have to click the “Update” button to apply the changes.
Bending:
Column design can be performed under uni-axial or biaxial bending. According to the member type, dimensions and member
forces, Orion selects the bending type automatically. But, the user can change the selection by clicking another option before
the design procedure.
Load Combinations Table:
The program will always design for all load combinations. At the end of the design it will highlight the critical combination.
Member force results from each load combination during the Building Analysis procedure are listed in a table.
In the design procedure, member force results from each load combination will be tried one by one. The critical combination
will be identified and used to select the reinforcement area.
Reinforcements Table:
This table contains several items of information:
1. Steel Bars
According to the steel area required, bar sizes are selected by the program automatically. The user can then modify
the selected bar sizes by considering the steel area required.
2. Required As
After design the steel area required will be displayed at the bottom of the table.
3. Supplied As
When the design procedure is completed, the steel area supplied will be displayed at the bottom of the
Reinforcements table.
4. Links
You can view the links selected for the current column in the “Links” page.
5. Shear Design
Shear forces on the section and the links provided are displayed in the “Shear Design” page.
6. Slenderness
This page can be used to indicate the column as braced in one or both directions.
7. Settings
General settings associated with the text.
Note: Because the BS8110 method is used the neutral axis will be horizontal or vertical depending on which axis has the
greater design moment. If the Bi-axial design method had been used the neutral axis would be at an angle
By selecting the Design Report option, the design for an individual column can be viewed.
The column has been designed using 10H12 bars and Combination 3 is the most critical.
The column is currently set as braced and because it is being classified as short, no additional moments are being added to
the initial moments.
Try un-bracing the column in the both X and Y directions and redesigning. You should find that this results in the
column being classified as slender and consequently additional moments are added. The column has now been
designed using 10H20 bars.
Click on the Column Analysis button in the Column Design Ribbon at the top of the Editor.
Column
Axial
Capacity
Column
Critical Axial
Load
The red line is the Dir 1 column capacity and the blue line Dir 2. Also plotted are the top and bottom moments determined
during the analysis of the building for each of the combinations. The horizontal red line indicates the axial load limit
determined by the code.
It can be seen that the design moments are very close to the moment capacity in dir 2.
The blue line on this diagram shows the M1-M2 capacities at the given axial load level.
Reduce the size of the bars to H10 as shown below. Note that the provided (sufficient) area is now less than the area
required.
Click on the Column Analysis button once more. Note that although the analysis moments seem OK, when you
display the design moments some of the results are plotted outside the interaction line, indicating the column fails.
Click on the Parameters button In the Column Design Ribbon and change the design method to Fixed Bar Layout
Method.
Click Ok
In the Steel bars table, enter the quantity for 1-int bars as “3” as shown (after changing the value ensure you click on
another cell to register the change). The bar layout is fixed, so that you obtain 3 bars in the 1-int direction.
A sufficient area of steel has been obtained, however it is perhaps on the heavy side.
Note: Link spacing for the supports and the span are calculated separately. If you want to use the same spacing both for
the span and the supports, uncheck the Create Support Regions for Links option under the Steel Bars tab of the Column
Design Settings form.
If you want to delete the support regions only in the current column, you can simply copy the size and spacing of the links
calculated for the span to the supports in the “Shear Design” page.
You can select other types of link, such as Cross Link or Double Links, from the Column Containment section of the Steel
Bars tab in the Column Design Settings.
Size and spacing of the links selected are displayed on the right of the page. Links for the span and for the supports are given
separately. Size and spacing of links can be edited on this page. If you press the Calculate button after selecting a new size, a
new spacing will be calculated accordingly.
The “number of link legs” provided in each direction are given in the bottom right corner. If a standard link type is selected
then these numbers will be determined by the program automatically. But if you want to describe a special link, you can
write the number of link arms into these fields.
Click on OK to save the modified design for column 1C2 and return to the Column Reinforcement Design window.
Important Note: In the Column Reinforcement Design screen, if you click OK to store a column while there is still a bar
spacing warning, the program interprets your action to mean that you have made an engineering decision to treat the
current bar spacing as acceptable. Provided the utilization ratio is less than 1.0 the beam would now be given a PASS
status.
In fact, the simplified equations and charts in BS8110 for rectangular / circular sections are all derived from this basic set of
“first principles” - see appendix A in BS8110 Part 3.
The column designs carried out so far have all been to the traditional BS 8.1.1.0-Cl 3.8.4.5 “codified” approach. Engineers
may like to use this method, as it's easy to check directly against hand-calculations, but remember you cannot use this
method for the irregular shaped columns.
Then click on the Interactive Design button to perform the wall panel design as shown below.
Select OK to confirm the design and to return to the Column Reinforcement Design list. Creating the Column
Reinforcement Plan
Then select the Column Application Plan view by clicking on the tab at the bottom of
the structure tree
As you can see below, this plan allows you to see the reinforcement placed in all of the
columns and walls in a single plan view.
Then right click to display the pop up menu as shown below and select Column Links.
Indicate where you want the links to appear on the Column Application Plan by left clicking. The position where you
click is where the bottom left corner of the links will be placed.
Note: You can also draw the links for all columns and walls grouped together in one go by right clicking and going to Arrange
All Steel Bars > Display Lateral Steel Of All Columns (Grouped)
Clear your selection, then right click and pick Arrange All Steel Bars > Steel Quantity Table
Left click on the plan view where you want the Top Left corner of the Steel Quantity Table to be displayed.
Right click and pick Arrange All Steel Bars > Column Longitudinal Steel Details
Left click on the plan view where you want the Bottom Left corner of the Column Longitudinal Steel Details to be
displayed.
This drawing can be edited and plotted directly from here. Alternatively it can be exported as a DXF File by going to File >
Model/File Export > DXF Export.
Note: This process uses the slab coefficient method from the tables in BS8110. This is independent of the general building
analysis and can therefore be carried out before or after the general building analysis. This method takes NO account of
openings or concentrated point/line/patch loads on the slabs.
The Design tab allows you to control the Cover, Top Steel Extension Lengths, Slab Span Lengths and the Support Band Beam
Widths.
Go to the Steel Bars tab and make sure the Steel Bar Spacing Step is set to 25mm to ensure that all bars within the
slab will be at multiples of 25mm In addition, as shown below, the bars will be spaced at no less than 100mm and no
greater than 250mm.
Additional slab steel detailing preferences are controlled via the View tab
6.1.3 Member and Steel Bar Label Templates (Additional Info. Only)
All Slab and Steel Bar, as well as Column and Beam, labelling settings can be adjusted by going to Settings > Member and
Steel Bar Label Templates, as shown below
Note: For clarity, the slab yield lines can be switched off while placing slab strips. To do this select
Settings > View Settings and then on the Slabs tab, uncheck the box Display Yield Lines.
Slab reinforcement is determined by inserting slab strips in the X & Y directions, which will automatically determine the
reinforcement required based on Table 3.14 from BS 8110. To obtain correct results it is essential that the slab types have
been correctly defined. The strips parallel to the horizontal direction axes will be labelled X1, X2 etc and those parallel to the
vertical direction axes will be labelled Y1, Y2 etc.
We will first enter a strip labelled X1 through the slabs between Grids A-B/1-5.
When drawing the strips it is essential that the correct At Start and At End conditions are
specified. The three options being:
Slab The strip starts or ends inside a slab. The bottom steel for the slab in question is not
designed, but the span of the slab can be defined and this value is used in determining the
support steel.
Bob The strip starts or ends beyond an edge beam or wall. The support steel at the edge is
bent down into the beam/wall.
Ensure the label is X1 and indicate a Bob at both the start and end of the strip by
clicking on the appropriate end conditions as shown on the right.
Then position your cursor between Grids A and B but to the left of Grid 1 so it is not in
the model, then press and hold the CTRL key and at the same time click and drag in a
horizontal line from Grid 1 to past Grid 5
Create another similar strip labelled X2 by repeating the process between Grids B-C/1-6.
Note: Although only two strips have been created in the model in the X direction, strips for all slab panels / conditions
should be created to complete the floor design in both the X and the Y direction.
Change the Dir setting to Y to show that you are cutting a vertical strip in the
plan view.
As this strip is going to cut through the cantilever at the end, change the At
End setting to Cantilever
If you drew the strip Y1 and you received a warning message as shown below, this is
because the strip has failed to satisfy the L/d deflection check. L is calculated at exactly
the point where you cut the strip.
Note: When placing strips you may encounter warning messages similar to the one above. Although the steel provided is
sufficient for strength it is failing the span/effective depth check deflection check. This problem will be resolved later by
editing the bar layout or changing the slab depth.
Note: This slab detail drawing can be exported to AutoCAD using the DXF export command.
By ensuring that when drawing horizontal strips, the strip name begins with X and when
drawing vertical strips the strip name begins with Y you will have flexibility to filter the
display of X steel, Y steel, top steel or bottom steel.
Pick Settings > View Settings and click the Slabs tab.
Select the bottom bar running vertically across slab 1S13 and display its properties
as shown.
As it’s failing in deflection, increase the bar Diameter to H10 and click Update
If you click Update and the above message doesn’t appear, the strip is then passing.
Note: The Steel Bar Property dialog also contains icons for editing/moving the bar span marks and moving the steel bar.
These can be used for improving the drawing layout.
Select strip X2 and then right click to display the pop-up menu.
Choose Slab Strip Check Design. This displays the calculations for
the X2 strip only.
A Preview of the Slab Report is displayed. Options are available to configure and then print it. You can also save the report in
a number of file formats.
Right click, select the Arrange All Steel Bars > Steel Quantity Table
Click to the right of the building, where you would like the table to be
located on the drawing sheet.
Note: The quantities in this table will only reflect the number of strips cut in the model. It is the users responsibility to
ensure the sufficient strips have been cut to achieve the accurate quantity.
Click File > Save Project As and rename the model by adding your initials to the end – eg:
Training_Course_Model_1a_R16 _(your initials)
Flat Slabs in Orion are modelled using the Slab Icon, however
as the slabs are no longer bound by beams the Type option
will not be relevant as the flat slabs can no longer be
designed using Table 3.14 co-efficients from BS8110. For all
Flat Slabs panels they should be inserted using Type 1, the
continuity of slab edges sharing the same axis will
automatically be generated in the Finite Elements Model.
Before creating the slabs in a Flat Slab model it is paramount that the layout of the slab panels is given consideration, and
the following guidelines are met:-
All walls (and beams, if any) must lie on slab boundaries – Columns can sit within slab panels
Slab boundaries sharing the same grid line will be continuous in the FE model
Slab panels should be as large as possible (Lots of small panels will complicate the FE)
Slabs should have the minimum edges possible (triangle/square/rectangle). Irregular shaped panels L etc. should be
avoided if possible
There is No Right or Wrong layout for the slab panels, but by adhering to the above, slab layouts should be simple
and effective when entering the FE environment
Left Click on the Insertion tab, and choose the Axis Region for
the Slab Insertion method. Note as there are no beams in the
model, the Beam Region (Default) method cannot be used.
Note: The use of the other slab insertion techniques will be introduced during the Day 2 training.
Hold down Ctrl and left click in the area bound by axis A/B, 1/2, you will see a red box appear showing the slab
perimeter
Continue to hold down Ctrl whilst left clicking in the area bound by axis B/C, 1/2 and C/D, 1/2, you will note the red
slab boundary increasing in size with every click
Create all the slabs on St01, using this technique until your model has the same slab configuration as shown below:-
To aid in the selection of the correct location of the line loads, it may help to switch the Axis Layer off, using
the Axis Layer Toolbar
Left Click on the Slab Load Tool, and specify a Line Load of magnitude 10kN/m for the Dead Loads only.
Note: Point and Patch loads can also be applied to the slab using the same
techniques. If a dxf had been imported into this model it would be possible to
snap onto the shadow, to enable to accurately model the location of any
additional loads on the slab, such as a corridor or plant room.
Left Click and drag to define the line loads around the perimeter, taking care to snap onto the slab corners.
As the line load has been created over more than one slab, a warning will appear asking you to confirm this was your
intention.
Place the remainder of the loads around the perimeter, as shown below:-
Enter the distance away from the grid where it is to be inserted as e1=1000, e2=1000
Note: Slab openings can be created circular or at an angle for rectangular/square openings. All slab openings must be
created using positive values for the e1 and e2 offsets from grid.
All holes must be created within a single slab panel.
Create a Type 1 – 300mm thick slab to the top of the shear core
Duplicate Storeys – The use of duplicate storeys should be used wherever genuine duplicate floors exist within the model.
The benefits as explained in the Beam and Column example still exist, but also when performing the Finite Elements Load
Chase down, duplicate storeys will not need to be re-analysed, therefore speeding up the load chase down procedure.
Unique Storeys – There will always be a minimum of 3 Unique Storeys in any multi-storey structure (shown by the Blue Dot
by the side of the Storey Label in the Workspace area).
Note: The top and the penultimate top storey cannot be identical, as the columns / walls at the top floor, only project
below the floor plate. Where as, the lower storeys all have columns / walls which project above & below the floor plate
which will effect the moment distribution from the slabs to the supporting elements.
We are going to use the same settings as used for the Beam and Column example, so there is no need to make any
changes to the Parameters / Load Combinations / Material Grades, Click Model Options Model Options
With the beam and column example all the slabs were
supported by beams, therefore the load could be
decomposed from the slabs to the beams. The use of
‘Decomposed Beam Loads’ could be relied upon to generate
the Storey Weight and Notional Horizontal Forces for the
structure.
Slabs are not modelled in the Building Analysis, which goes some way to explaining why the Undecomposed Loads must be
used for Flat Slab Models. Slabs are replaced by a series of Diaphragms (based on the user’s settings) within the Building
Analysis, but are able to transfer gravity loads to the columns and walls.
This will check that the building is valid for those conditions indicated.
`
Assuming that no errors are reported, close the dialog
Note: During the Building Analysis, the Lateral Loads for the model will be generated. There are NO Supporting Beams
for the slab loads to be distributed onto. Therefore, ONLY THE LATERAL FORCES will be correct after the Building Analysis
has been performed.
THE GRAVITY LOADS WITHIN THE MODEL WILL BE INCORRECT, this will become apparent when viewing the ‘Axial Load
Comparison Report’.
Ensure that Column/Wall Reinforcement Design and Beam Reinforcement Design are Unchecked before clicking on
Start to begin the batch analysis process.
Click Start to begin the Building Analysis Calculation, and a warning message should be displayed.
The warning shown above indicates that Gravity load has gone missing. This is because there are no beams in the model for
the slab loads to decompose onto. This illustrates that an FE load chase down is always required to obtain the design forces
for the member design for flat slab models.
8.3 Post-Analysis
8.3.1 Cross Checking the Analysis Result
As we found in the previous example the Axial Load Comparison Report is a good way of investigating how the load is being
decomposed throughout the structure.
The total ‘SUM OF APPLIED LOADS (Using Un-Decomposed Slab Loads)’ values should be similar to those from the
Decomposed Slab Loads table if the Building Analysis Results are to be correct. It should be clear from this report that vertical
load has gone missing; therefore the gravity results due to the Building Analysis will be meaningless. This again emphasises
the fact that an FE load chase down is required.
The Analysis results can be viewed graphically again, but the only results of any significance will be those for Lateral Loads –
NHF’s / Wind etc.
The diaphragms formed during the analysis can be viewed along with the Major Axis Moments and displacements for Nx or
Ny.
The frame sways under the lateral load case Nx as shown below:-
Column/Wall Model Type – There are 3 options held within this menu, but only the ‘Short Frame Model’ includes the
columns and walls within the FE analysis. This enables moments to be transferred from slab to columns/walls; this option is
also required to perform a load chase down.
Stiffness Factors – To take Cracking and Creep into account, we need to look at the long term stiffnesses of the elements.
These factors are used to adjust the EI values and enable us do this. They can either be adjusted manually or Orion can
calculate appropriate values by using the Cracking and Creep tool. Stiffness adjustments are discussed further in the Help
system and in the Day 2 training course, or in The Concrete Centre publication ‘How to design reinforced flat slabs using
finite element analysis’ by O Brooker, May 2006.
Include Column Sections in FE Model – Checking this option allows the physical dimensions of the columns to be included in
the FE model, by using a series of Rigid Arms, instead of simply modelling to the member centrelines. This will reduce the
high peaking hogging moments over supporting columns for a Flat Slab design.
Include Slab Plates in FE Model – For Flat Slab Models you must check this option. For Beam and Slab Models if this option
was un-ticked, it would allow a load chase down to be performed based on the beam load decomposition technique derived
for the Building Analysis (Yield Line or FE for Beam Loads).
Consider Beam Torsional Stiffnesses – If included then hogging can develop in the slab adjacent to the perimeter beams.
This must also be included if any slab within your model relies upon the torsional capacity of a beam within the model for its
support. Torsional values will be calculated; however Orion does not consider Torsion within the Beam Design.
Include Upper Storey Column Loads – If you wish to chase the load down through the structure this option must be selected,
even at the top storey. This will allow the transfer of load and column / wall self weights, from floor to floor during the
analysis process.
These values are the average area loads applied to the slabs,
including the slab self weight.
For the purposes of this example, ensure you have the same settings, as highlighted as above
1. Mesh and Analyse the Top Storey, to generate the Column/Wall forces.
2. Mesh and Analyse the Penultimate storey. Reactions form the floor above becomes applied loads on the floor
below.
3. Continue this process floor by floor down through the structure (excluding duplicates)
4. Mesh and Analyse St01 to chase the load down to foundation level.
5. If no adjustment is made to the slab to allow for the Long Term effects in the model, you will be warned before
allowing entry into the FE Floor Analysis.
Note: The Stiffness Factors have been altered (0.33) to allow analysis results to be viewed for the Long Term Modulus of
Elasticity (E). Within Orion there are various ways these adjustments can be achieved (though this is the recommended
method) which will affect the results. Therefore, we will no see the above message. These techniques will be discussed
during Day 2 training, or by referring to ‘The Concrete Centre Publication – How to design reinforced concrete flat slabs
using Finite Element Analysis – O Brooker May 2006’
Plate Element Size – The smaller the size of the plates, the more plates you have in the model and the longer the analysis will
take. We recommend a minimum of 6-8 plates is achieved between column support locations. The Default plate element size
is 800mm. This is normally sufficient to provide the minimum of 6 plates between supports but it can be increased or
decreased depending on your model.
Mesh Uniformity Factor – The higher the mesh uniformity value, the more equal in area all the plates become, with the
exception around columns for certain locations / geometry. The lower the mesh uniformity factor, the more plates there will
be, and in a much more varied size.
Note: Finite Element Analysis is ONLY used for the determination of Gravity Loads on the structure, hence ONLY G (Dead)
and Q (Imposed), will be available in the Loading pull down menu.
Click Generate Model with 800mm plates and Mesh Uniformity Factor of 25%
This maintains 6-8 plates between a lot of the column locations but may be a bit dense. Note the difference below for Mesh
Uniformity Settings at 100% and 25%. Alternatively, smaller plates could have been used. These settings can have a big
impact on your mesh, and hence results, so you shouldn’t just accept the defaults; always take care to try to obtain the best
mesh possible.
With the floor meshed with 800mm plates and 25% mesh uniformity, close the window for the analysis to complete,
then click back on the Model Preparation tab.
Note: Within the FE model, the plates have been formed around the column heads. This is due to ticking the option
within the FE Analysis Form ‘Include Column Sections in the FE Model’. Although this option allows the physical
dimensions of the columns to be modelled in the FE environment, this does rely upon a more complicated mesh being
formed around the column heads. However, it will potentially give more realistic results as it reduces the peak moments.
You will see as St04 has already been analysed - A green tick appears beneath the Analysis Status.
Left Click on the Shell Element Size text. Without clicking anywhere else Type 800, then hit Enter.
This will change the plate size for all floor levels to be 800mm. This can be done for all settings in the
Batch FE Chasedown Window.
Ensure the Include Slab Plates in FE Model is ticked on for all floors
Set the Slab and Beam Stiffness Factors to be 0.33 for all floors
Set the Column and Wall Stiffness Coefficients to be 0.33 for all floors
Ensure the Consider Beam Torsional Stiffness is ticked for all floors
When complete the window should look as follows, make sure the Include Upper Storey Column Loads is ticked:
Note:-
Although in today’s example we are
choosing not to Pause at Check
Meshing at Each Floor, it would be
strongly recommended that this
option is left ticked for the first
analysis run so that the user can
satisfy themselves that the mesh is
adequate at every floor in the model.
Orion will now Load the Pre Processor, Form the mesh at each floor level, and analyse before moving down to the next floor.
This operation could be performed manually by forming the mesh and analysing each floor, and then selecting the floor level
below, excluding duplicates.
All deflection results are based upon the Slab, Beam, Column
and Wall Stiffness Factors applied in the ‘Batch FE
Chasedown’ Window.
Click Close in the Finite Element Analysis Form, only when the Merge the Column box is ticked.
Note:
The Merge Column Results with Building Analysis, is only required to be done once at the end of a Full FE
Chasedown.
When choosing this option ALL the G & Q results will be replaced on every level throughout the structure.
At any time you can quickly toggle between the Building Analysis and FE Analysis Results, by ticking /
unticking this option.
The same principles would apply should we have any Beams within the Model.
Now we have two sets of results for the Gravity Loads in the model (G & Q), we must choose which results we are going to
use for the design of the Columns (and Beams if applicable). For all Flat Slab models the results from the FE Analysis should
be used, for obvious reasons.
Merging the column results will take the Vertical Loading Results from the FE Floor Analysis and the Lateral Loading Results
from the Building Analysis to give a complete set of results that can then be used to design all elements.
This will become obvious if the Display Loads/Forces on Plan View in the View Settings is switched on to display LC1: G,
LC12: Q, Cmb1: (G+Q)*F
Tick the option Bottom to display the axial loads at the bottom
level of the columns and walls
Now view the merged Axial Loads for Column 1C1 at level St01.
These are the CORRECT results.
If you had not merged the correct Vertical Load Results from the FE Analysis, then these results would look quite different, as
shown below. These are the Building Analysis Results only; hence the Axial Loads are INCORRECT. The loads shown will
reflect only the Self Weight of the Column or Wall, rather than any decomposed load from the slabs to the columns. Hence,
the Dead Load in the column is much lower and there is no Live Load, as for this model, Live Load has only been applied to
the slabs.
Note:
When the FE chasedown has been completed, an extra table is added to this report (table 4),
containing the Finite Element Analysis Column/Wall Axial Loads. The sum of these loads should equate
(within a few percent), to the sum of all the dead and live loads applied at each storey level. If they do not,
the reason for the discrepancy should be investigated. The report can be accessed from both the Building
Analysis and the FE Floor Analysis forms.
Go to Run > FE Floor Analysis > Post Analysis Processes and Reports tab
Table 1, as shown above, shows the Sum of the Applied loads using Undecomposed Slab loads. This includes the self weight
of all elements and any additional loads applied to them BEFORE decomposition. This table is correct.
Table 2 shows the sum of the applied loads after decomposing the slab loads. For this model, this is based on the Yield Line
method and so for a flat slab model, this table will be incorrect.
Table 3 shows the Column/Wall Axial Loads based on the Building Analysis results, which as we already know, are incorrect.
Therefore, we should ignore Tables 2 and 3 and just compare Tables 1 and 4.
Below is a quick summary table to compare the results from Tables 1 and 4.
Orion calculates the percentage difference between the overall loads applied and the overall reactions, as highlighted above.
As you can see there is only a difference of 0.52%, which is more than acceptable, so we can now move on to the design.
Note:
There will always be a slight variation in Table 1 and Table 4. This is due to the FE analysis being
performed on a centreline model, and therefore slight overlapping of the slabs and the beams/walls will
occur.
There will also be differences due to the fact that the Building Analysis does not include the slab elements,
hence any openings will not be considered within Table 1.
Tables 2 & 3 are to be DISREGARDED, as there is no beams in the model for the slab loads to be
decomposed onto, the results in Tables 2 & 3 are meaningless in a Flat Slab Model.
Ensure St04 is selected and a Positive Moment Factor of 1.2 has been entered
Note: FE floor models do not include for any pattern loading. It is not feasible/logical to automate pattern
loading to generate every possible worst case scenario, for every conceivable irregular arrangement and
any size of model. A more realistic use of these adjustments is to amplify the sagging moments (by using a
positive moment factor of perhaps 10-20%).
Click on the Analysis Post-processing button
From the Results Ribbon the following buttons allow the display of Displacements and the Contours on the model.
The first option Displacements shows the displacement diagram of the mesh, for the selected storey.
The Standard Contours shows the contours of the selected Loading and Effects
Note:
The displacements shown in
the contour plots are based
upon the adjustments made
in the FE Analysis Form for
the Stiffness Factors, to
allow for the effects of Long
Term effects due to (Creep,
Cracking and Shrinkage).
3. G+Q*F – This is the Factored Dead + Live Load Combination – If you have used the ‘Cracking and Creep’ tool to work
out your Stiffness Factors, these deflections can be taken as Unfactored. If not, then you must manually defector
them.
There are various different Effects which can be viewed in the Floor Analysis Post Processor.
These display, Global and Local effects, along with the Displacements / Moments / Area of Steel Requirements for the
selected floor plate.
Mxy The average Nodal Torsional Moment relative to the Global co-
ordinate system (Wood & Armer Adjustments)
As1-bot Required Area of Steel in the bottom face of the slab along Direction 1
As2-bot Required Area of Steel in the bottom face of the slab along Direction 2
As1-top Required Area of Steel in the top face of the slab along Direction 1
As2-top Required Area of Steel in the top face of the slab along Direction 2
Note:
Any contour plot which displays a d within its name allows for the effects of Wood and Armer adjustments.
Example Md1 or As(d)1
Unless you have a specific reason for ignoring the Wood and Armer adjustments, it is recommended that you
should ALWAYS work with the Md and As(d) results.
These adjustments take plate torsional moments into account to generate adjusted design moments. If a detailed
background of these adjustments is required then reference should be made to the original papers:-
Wood, R.H. “The reinforcement of slabs in accordance with a pre-determined field of moments” as published in
Concrete 2.Feb 1968, pp69-76
Md1-bot The sagging Moments in the bottom of the slab in Direction 1 which include for the effects of Wood and
Armer adjustment
As(d)1-bot The area of steel requirements (based on the Effective Depth) in the bottom of the slab in Direction 1 which
include for the effects of Wood and Armer adjustments.
Note:
Hogging Moments will be
denoted with negative
values.
Sagging Moments will be
denoted with positive
values.
From the Results Ribbon > Contours Panel, and select Concrete Cover
Click on the Concrete Cover (to Bar Face) and type 25mm
Ensure the Dir 1, is set to Layer 1 (Outer) – this will then place the horizontal bars (in plan) in layer 1 i.e. the bars
nearest the upper and lower surface of the concrete.
Click OK
All of the Area of Steel contour plots will now be produced based upon these settings for the effective depth. Please note
adjusting these values will effect each and every As and As(d) contour plot.
Note:
The pull down menu at the side of the User Defined Contours option allows the user to change the display
settings.
Shaded / Lines / Contour Values can all be switched on or off within this screen, this has no effect on the
model.
From the Results ribbon > Contours Panel, select Edit Contours
Click Update
The Min and Max values cannot be altered but the Contours in-between can be used based on actual bar sizes and spacings.
Note:
The second contour will be based upon alternate H10 and H16 diameter bars @ 150mm spacing’s.
Note:
The blue areas in the contour
plot denote where H10 @
300mm is sufficient.
The green area of the contour
plot is where H10@300 plus
H16 @ 300mm is required.
IMPORTANT
All contour plots are based
upon exact values, therefore
these plots DO NOT include for
Anchorage Lengths
Ensure the Contours = 4 and the Legend is set to Both and click Update
Set the third contour to H10 @ 300 plus H20 @ 300 plus H25 @ 300mm
Click the Update button after completing the settings for each contour
Click OK
Contour Settings
This will then enable the selected contour to be exported into the Main Modelling area of the program. This would have to
be done for all four contours, top and bottom in direction 1 and direction 2.
Left click on the Close window (X) to exit from this window and back into the main model
On the Transfer Options window select OK. If any strips had been cut in the Model this window allows transfer of this
information from the FE analysis.
Left Click Close to exit the Finite Elements Floor Analysis form and to return to the Plan View.
Click OK
If the contours are not displayed Left Click on the Regen icon
The graphical display should now look as shown below, with the contours for As(d)1-top exported.
All the layers will be automatically identified and transferred into AutoCAD, based upon your Layer Control settings.
Any drawings created using this option will be stored in the [Default] directory for the current job (unless changed by the
user) – C:\Documents and Settings\All Users\Documents\Orion 16\Training_Course_Model_1a_R16
Note:
For Flat Slab Models the column design MUST be based upon MERGED Column Forces from the FE model.
Otherwise the design of the columns will be incorrect.
New bars will then be selected based upon the Column Design Settings applied in this mornings training session, as shown
below:
All the columns have now been designed using the Finite Element Analysis Results for the Gravity Loads (G and Q), and the
Building Analysis Results for the Lateral Loads (Nx and Ny).
11.0 Appendix A
Wind Loads
In order to add wind loads to the model, you should ensure that you have Wind Load Cases created and Load Combinations
set up that include these Wind Vectors.
Go to Run > Building Analysis > Pre-Analysis > Edit Load Combinations
Click the Loading Generator and tick the option to create Wind Loading
Click OK
You will now see that there are 4 Lateral Load Cases, Nx, Ny, Wx and Wy, and Combinations have been created that include
each of these – e.g. G+Q+Wx as shown below.
Go to Run > Building Analysis > Pre-Analysis > Edit Storey Loads
By clicking on each of the storey labels in the upper table, the Wx and Wy values for each storey can be entered in the lower
table.
0,0 X
Wy
The load is transferred to the columns and walls via diaphragm action
within the floor. The diaphragm model is defined on the Model Options
tab of the Analysis form.
It is up to the Engineer to work out the coordinates and the wind loading to be applied. However we are given the
coordinates of the centre of gravity. We can make use of these numbers to work out the coordinates to the centre of the
elevation.
Use the dimension tool to show the distance to the centre of gravity and the length of the elevation.
In direction one.
Centre of elevation is 19800 mm / 2 = 9900 mm
Distance of the centre of elevation from the centre of mass is
9900 mm – 9071 mm = 829 mm
X coordinate is 14.071 m + 0.829 m = 14.900 m
2
For simplicity assuming 1.0 kN/m wind loading
The loading in the Y direction Wy = 19.8 m 4m 1.0 kN/m = 79.2 kN
2
In direction two.
Centre of elevation is 27219 mm / 2 = 13610 mm
Distance of the centre of elevation from the centre of mass is
13610 mm – 12341 mm = 1269 mm
Y coordinate is 17.341 m + 1.269 m = 18.610 m
2
For simplicity assuming 1.0 kN/m wind loading
The loading in the X direction Wx = 27.219 m 4.0m 1.0 kN/m = 108.9 kN
2
Note: In practice the loadings and coordinates may change due to variations in floor layout and storey heights. For this
example we will assume they are all the same.
Enter loads for the other storeys in a similar manner, and then click OK.
Return to Analysis, check the Building Analysis box and then click on Start.
The building should now be analysed for the wind load combinations in addition to the other combinations.
Click on the Post-analysis tab and press the Model and Analysis Results Display button.
Using the settings and Filters you can select a wind case and view the results from that case. Viewing the
deformations clearly shows the twisting effect caused by the offset of the coordinates
Select a column and right click. From the menu choose Add Column/Wall Nodal Load.
The load can either be applied to the selected column, all columns/walls in the current storey or every column/wall in the
model.
Select the required Wind Load Case and enter the load values to be applied. Note that the loads are applied using
the global co-ordinate system.
You can enter multiple loads and moments under every available load case at the same time.
Once you have entered all values, click OK for them to be applied to the selected members
12.0 Appendix B
A brief overview of the options in general and then more specifically the reinforcement pattern options, is provided in the
next few pages.
These settings are generally self evident, they will tend to have a slight influence on the values of As required that emerge
from the design. For example the options to design for the shear at the column face and to use the rectangular section
(rather than the flanged section) when the flange is in compression will result in slightly more conservative steel area
requirements.
Again, these settings are generally self-evident, they set limits on the ranges and spacing of bars which are considered when
bars are being selected to provide reinforcement which at least meets the minimum requirements determined during design.
In this tab we start to apply more specific preferences which will affect the way in which bars are selected to meet the As
requirements determined in design. Standard Pattern 2 is currently the most commonly used option. Many of the other
options under this tab and also under the curtailments tab are more “tuned” to standard pattern 2.
Note that on the Method sub-tab, the option to maximise bar spacing is the default. The option to minimise bar sizes is not
often used because lots of small bars end up being used at close centres rather than a few larger bars at wider spacing.
In this tab we apply preferences as to how the reinforcement is curtailed. Although this is not under the “detailing” tab, these
sorts of preferences are more traditionally applied by the detailer rather than the designer.
In this tab all the preferences relate to detailing presentation options, i.e. changes here only relate to presentation and not to
the reinforcement selection.
Settings in this tab control the layering, line types etc to be used in the DXF file, which can be loaded into most general
drafting packages.
If you have made any changes to the Settings and Parameters select Save to update them and return to the Graphic
Editor.
To bring the beams on a particular axis onto the drawing sheet, perform the following steps.
Left click and hold on the axis name and then drag the beam onto the sheet
Position the beam where it is to be placed then release the left mouse button.
To manipulate the beam position click and drag the beam around the sheet
To sort according to the storeys, Select Settings and then select Storey.
Repeat this process for some more of the axes so your screen looks similar to below.
Now insert the reinforcement quantity table for these beams on Sheet 1
Now select OK
Select the New Button next to the Sheet No. Box so the following
appears with a no. 2
Click OK
Repeat what we have done so far for Sheet 1 by selecting some more beams.
Note: You can’t select any of the beams which are on Sheet 1 or those not previously designed.
Choose Save and then Exit to get back to the Beam Section Design and Detailing window.
Go to the Menu and select Sheet > Beam Detail Drawings to get the
following screen.
If any of the bars have been truncated you will be informed where they are and you
will then need to click on OK to get to the following screen.
If necessary, edits can be made to the drawing using the various commands that are available. Alternatively the drawing can
be exported as a DXF file and amendments made in another cad program.
13.0 Appendix C
Note: Min Steel Percentage will be taken from Table 3.25 in the code, Max Col Steel Percentage will be 6.0% and Max
Wall Steel Percentage will be 4% unless you overwrite the default ( 0.00 ).
Plain Wall Design allows the design of walls without reinforcement where the wall is subject to compression throughout and
the steel requirement is zero/negligible.
By default Orion is set to use the BS8110 method for bi-axial design, however an alternative true bi-axial approach is
available. This latter method can produce some economy; however it is perhaps best thought of as a means to occasionally
fine tune a BS8110 design. You may decide to design using the true bi-axial method and then check the reinforcement using
the BS8110 method. Clause 3.8.4.4. is the more conservative. However, if cl 3.8.4.3 is appropriate, less conservative results
can be achieved.
These settings are fairly self explanatory; however some consideration should be given towards the selection of appropriate
lateral steel.
Details of the ‘Steel Bar Selection Method’ are displayed in the blue text below the setting. The option to maximise bar
spacing is the default. This option reduces the congestion compared to the option to minimise bar sizes.
The Column Lateral Steel Types can be set by clicking the Column Containment sub-tab.
Clause 3.12.7.2. specifies requirements to contain compression reinforcement by the introduction of links and/or tie bars.
The Single Link option or any of the other options should be regarded as manual over-rides: the user takes responsibility for
adding extra bars to satisfy cl 3.12.7.2.
The Wall option (without End Zones) is more efficient at lower loading levels as minimum steel requirements start to
dominate.
The Wall w/End Zones option would generally not need to be used. It might however become more efficient when the walls
are resisting significant in-plane moments.
The Single Layer Wall can be selected for walls up to the thickness specified in the ‘Max. Width for Single Layer Walls’ dialog.
The Single Layer Wall w/End Zones is the same as the above, but also includes End Zones.
The settings on this tab are fairly self explanatory. For example the max bar spacing has been set to 200mm.
Note: Concrete cover 0.00 mm means the amount of cover will be taken from the code, as noted below
the setting in blue. If a non zero value is entered, this will be used instead.
The Mesh Steel tab allows the user to use mesh for the design of the walls rather than loose bars. The mesh sizes used will
be based on the settings from the Building Analysis Form > Edit Materials.
Now click on the Detail Drawings Tab and set the parameters to be as shown below.
In this tab all the preferences relate to detailing presentation options, i.e. changes here only relate to presentation and not to
the reinforcement selection. The Layers tab works in exactly the same way as for the Beam Design Settings – see page
Appendix B, page 180.
Click on OK to save the design parameters for the columns and walls.
From the Design ribbon > Design Panel, choose Steel Standardisation
Select Column Line E-2 (1C9) as shown. It can be seen that three different bar arrangements are used up the height of
this column.
Click on Save Axis then Close. The Utilization Ratios for the modified columns are recalculated.
The steel bar pattern for 1C9 is copied to the clipboard. All columns with the same b1 and b2 dimensions are marked “=”
indicating that they are suitable for pasting this bar pattern to. The user can then either paste to individual marked columns
using the Paste Steel Bars from Clipboard icon, or paste to all marked columns using Paste Steel Bars from Clipboard to All
Similar Columns.
Note: It is possible to paste a steel bar pattern that is insufficient. If you do this, the Design status will indicate fail for
those columns and will be shown as such in the Design status. These could be re-designed interactively.
From within the Column Reinforcement Design window select the Detail of Selected Column icon
The Column Axes List option will create a drawing of a single column by clicking on the Draw icon.
If multiple columns are required on the same drawing sheet, the Sheet List option should be used as follows.
Change the Sheet size to A1 and then bring the column details on to the drawing by clicking and dragging the column
references from the table on the right into the drawing sheet area.
Click on Save to save the above layout as sheet 1. Additional sheets could then be created as necessary by clicking on
the New button. When completed click on Exit
This drawing can be edited and plotted directly from here. Alternatively it can be exported by clicking on the DXF Export icon
and then opened and edited further in AutoCAD.
14.0 Appendix D
Foundation Design
Some further, more detailed, preferences are set in Setting > Foundation Design Settings.
If you have already modelled and analysed the building above the foundation in Orion, the loads can be transferred directly
to it. Alternatively if you only want to perform the foundation design without modelling the structure above then the load
can be input manually.
Assuming you have already analysed the structure above the foundation, you have the option to either transfer the loads
resulting from the Building Analysis, or (assuming you have performed a gravity load chase-down) the loads can be based on
the FE Analysis results.
Select FE Floor Analysis from the Run menu in the Main Menu bar.
Check the box Merge Column Results with Building Analysis Results.
Note: To design the foundations using Building Analysis results, leave the box unchecked.
Select columns 1C2 and 1C3 and the right click and select Insert Pad Base as shown
Increase the footing depth to 600mm and change the bar sizes to H20 then click on the Calculate button.
A rectangular footing has been designed for the worst loads from both columns.
Note: The ‘unlocked’ icon in the middle of the screen indicates that if the Lx dimension is increased the Ly dimension will
remain unchanged. The icon can be changed to ‘locked’ by clicking on it. In this case, if the Lx dimension is increased the
Ly dimension will be automatically recalculated to suit.
Change the above icon to ‘locked’ and check the ‘Square Footing’ box to have the footing recalculated.
If desired the bar spacing’s in the XX or YY directions can be amended at this point.
Click on OK and then click on OK again to exit from the Pad Base Properties dialog.
The pad bases are then inserted under the selected columns as shown.
Choose an A3 page and then click and drag the F2 footing out of the table and on to the drawing sheet.
Click with the left mouse button as necessary to reposition the footing so that it fits within the page border and then
add a steel quantity table
To return to the Graphic Editor, click on the Form Plan icon at the base of the structure tree.
Note: This section of the training manual should only be considered as a brief introduction to the Strip Footing
capabilities of Orion. This subject is much more comprehensively documented in the Engineer’s Handbook.
When designing a strip footing under a continuous wall in which no bending takes place along the major direction of the
wall, the pad footing option can be used. Select the wall, and right click to insert a pad footing.
Create a 600mm wide by 800mm deep beam between columns C1 and C5, then another between C5 and C8 and a
third between C8 and C12
Select all three newly added beams and then right click and select Insert Strip Footing.
Checking the Design Envelope box will design the footing for all load combinations.
Select H20 steel diameter and increase the footing depth to 800mm, then click on Design.
Click Calculate and the program works out a required Footing Width and displays a report
Close the report then round the width up to 2900mm and click on Design once more.
Click OK to exit, and then OK once more to return to the Graphic Editor.
Go to Run > Beam Section Design and Detailing > Create/Update Footing Beam Records.
Click Yes to update the records, then go to Run > Beam Section Design and Detailing > Foundation Beams.
From this point the beam design procedure is carried out in a similar manner to the design of superstructure beams.
Create a 600mm deep slab inside the lift core as shown below.
Adjust the Mesh Uniformity Factor and Plate Element Size, then mesh the floor
Exit from the mesh generator and continue with the analysis.
Shown below is the Contour diagram for the effect – Soil Pressure Threshold. This indicates that the soil is overstressed. It is
necessary to make the raft larger.
Exit from the Post Processor and then in the graphic editor try increasing the raft size.
Once a satisfactory size has been obtained, reinforcement can be placed in the raft in the same way as was done for the
other FE slabs in the building.
15.0 Appendix E
The five check boxes at the top of the Load Templates enable the creation of basic patterns which are referred to as P1, P2,
P3, P4 and P5.
Pattern P1 applies ‘adverse’ load to the first span, ‘beneficial’ load to the second span and so on. Hence making the
selections shown above would result in the following combinations being created:
GP2
GP1 or QP1 (=_=_...) or QP2 (_=_=…)
Direction 2
QP11 Direction 1 QP12
QP21 QP22
QP31
QP32
QP41 QP42
QP51 QP52
By default, each floor level is initially considered to be a stage. The first stage must always include storey 1; however, it and
each subsequent stage can be adjusted to include more than a single storey. The stage duration can be initially set in the
screen above, and is set as 15 Days by default, though this can be edited. By default, all stages initially have the same
duration, however individual stage durations can be edited as required.
Once the loading has been generated, it is then possible to adjust the content and duration of the stages via the ‘Load Cases’
button. Highlight the construction stage load case you want then click the edit button. All stages will then be listed and the
storey (content) and duration can be adjusted.
The construction stage is useful where concern relates to the estimation of deflection affecting brittle finishes, and can have
a big impact. For more information on this topic, please refer to the extensive Help System within the program.
Lateral Loads
Notional, Wind and Soil Pressure load combinations can be generated automatically.
Notional Load
Ticking this box creates four additional load combinations of gravity and notional horizontal load as shown below. In each
case the notional load is applied at the centre of gravity of each floor.
Note that where the load factors are negative in the above table, this indicates the load is applied in the reverse direction.
Wind Load
Ticking this box creates four additional load combinations of gravity and horizontal wind load as shown below. The point of
application and the magnitude of the wind load at each storey are input by the user via the Storey Loads Editor accessed via
Building Analysis. Refer to Appendix A for details.
Soil Pressure Load
Ticking this box creates additional load combinations of gravity and soil pressure load as shown below. The point of
application and the magnitude of the soil pressure load are input by the user via the Storey Loads Editor accessed via Building
Analysis.
Temperature Load
Ticking this box creates additional load combinations of gravity and temperature load as shown below. Temperature loads
can be applied by selecting a column, wall or beam, right clicking and selecting Define Temperature Difference Data. You
can then apply either Axial or Gradient temperature loads to specific members and member groups.
16.0 Appendix F
Report Manager
Choose Concrete Quantity Extractions Table and then click Create Report.
In the Orion report, click on the Save Report Button then Close and return to the Graphic Editor.
Repeat the process to create a Column/Wall Steel Bar Table and Save this report too.
Use the arrows to select those reports that are to be printed as shown.
17.0 Appendix G
The Polyline Column Editor shown below allows any shape of column to be created.
The sections shown to the right can be quickly created using the Standard Column Section icon, however in this example
the column section will be created manually.
Change d(next) to 550 and click Apply. This sets the distance from this vertex to the next, which is in this case vertex
0. The left hand edge is therefore now 550mm.
Left click on the line between vertices 2 and 3 to create a new vertex as shown.
Right mouse click on the new vertex 3 and pick Edit Vertex Information. Change Angle(next) to 180 and d(next) to
300 and click Apply as shown.
Left click on the line between vertices 2 and 3 to create a new vertex as shown.
Right mouse click on the new vertex 3 and pick Edit Vertex Information. Change Angle(next) to 90 and d(next) to 250
and click Apply as shown.
Click Close.
You should now have an L-shaped column of size 300x550/300x600 as shown below.
The origin point shown inside the column indicates where it will be placed relative to the grid line intersection. Clicking the
Origin Point button allows you to change the origin position if required.
Click OK to exit from the Polyline Column Editor and save the new shape.
The column at Grid B/1 will be transformed to the L-shaped column as shown.
18.0 Appendix H
Note: The slab design based on FE strips which is discussed in this chapter can only be performed if a set of FE results are
available for the floor in question. We will design St04.
First, click on the Slab Strip icon to display the Slab Strip Properties.
Note: Additional strips can be positioned as required. An FE strip can be distinguished from a coefficient strip by the FE
label that appears at the end of the strip.
Select the FE Floor Analysis from the Run menu in the Main Menu bar.
Changing the Stiffness Factors may affect the results. More information on this is provided in the Engineer’s Handbook and
in Chapter 9 of this manual.
Ensure the Stiffness Factors are all set to 0.33 and you have the below settings
Now choose File/Exit to get back to the Finite Element Analysis Form dialog box.
This takes you to the Post-Processor window with the model displayed as follows:
From the General Ribbon, click on the Plan View button as shown:
From the Results Ribbon, select the Standard Contour icon various effects can be displayed.
By manipulating the loading and effect drop-downs various other results can be viewed.
By selecting the Standard Contour icon once again the contours can be switched back off.
The results for the existing FE strips can be displayed using the Select Strip drop down.
The Moment diagram for strip X2 and the G+Q*F loading should appear as below.
Note There are options to plot either Moment or Design Moment. The latter incorporates the effect of additional Wood-
Armer moments in the slab. In this particular example because the slab panels are all quite close to being rectangular there is
not much difference between the two. In some models (where the slab arrangement is more irregular) the Wood-Armer
effect can become significant.
Note The diagram is plotted using values calculated for the number of longitudinal points along the length of the strip. The
tabulated values shown below the diagram are obtained by taking the maximum nodal results in each zone of each slab. The
zones are colour coded and can be seen on the screen behind the slab strip moment diagram, as shown below. The nodes are
coloured green in the support zone and orange in the span zone. The tabulated values are used for the reinforcement strip
design - not the values along the strip itself.
Exit to return to the Floor Analysis Post-Processor window and choose File/Exit once more.
Ensure both boxes above are checked, and then select OK. This will transfer the FE slab strip results taking into
account the additional Wood-Armer moments.
Choose Update
Any failing bars can be edited in exactly the same way as for the strips cut for the Moment Co-
Efficient Method.
Slab Output again can be created in the same way as the strips for the Moment Co-Efficient
Method.
19.0 Appendix I
So you should now have the Linear Dimension dialog box as shown below.
The next row can be used to indicate if Continuous or Automatic dims are required and
also if the dim is to appear on the current storey only, or all storeys.
The third row is used to control the appearance of the extension lines.
Usually, dimensions are inserted with scale as "1". If two different drawing scales are
utilised on the same sheet (as in the column application drawings) the Dim Scale option
can be very useful to dimension entities drawn to the second scale.
Now we can dimension up the vertical grids. You will notice the status bar at the bottom of
the screen is prompting what to do next…
Click to the left of Grid 1 and drag to beyond Grid 6 and then release the left mouse button.
The status bar at the bottom of the screen then asks you to click on where you would like the dimension line to appear, as
shown below.
Ensure that the Axes and Insert Total Dimension boxes are checked as shown below.
Select OK.
So your screen should look as shown below where the total horizontal dimension will be 19800. This can be checked by
zooming over the total horizontal dimension
Select the Vertical Dimension direction and keep the automatic dimension selected.
Then click and drag from below Grid intersection A/5 to above Grid intersection F/5. Release the mouse button and
then click on a point to the right of Grid 6.
In the Automatic Dimension Parameters dialog ensure only Axes and Insert Total Dim is checked as shown below.
Then select OK
To snap to the top corner of the slab go to Edit > Object Snap Settings and ensure Intersection is ticked.
Click a position above the slab where you want the dimension to appear.
Right mouse click on Axes in the Structure Tree to display the menu shown.
Another feature on the same menu, which can make drawings clearer, is the option to set unused axes as ghost. This will
identify any axes that are not being used on a particular storey and place them into a ghost layer. This layer can then be
switched off.
This feature is particularly useful where the floor layouts change from one storey to the next. In the training model this is not
the case. So it won’t be used.
Position the cursor to the left of Grid 1 between Grid E-F above the slab opening
Press the CTRL key and click then drag the mouse so that it extends beyond Grid 5.
If necessary, select Zoom Limits then click above the top of the vertical grids to insert the Horizontal Cross-Section (A-
A)
To get the reinforcement shown in the section, you must have designed the slabs with strips, then:
You should now have 2 cross sections on your screen as shown below.
In Section B-B you can see the core walls. The amount that the walls (or columns) project above or below the section is
controlled using the Upper Col and Lower Col Len boxes.
20.0 Appendix J
Orion creates a folder for each project and saves all project files in this folder. In other words, all the files for a given project
will be located in the same folder. These folders will be named as the Project Code specified by the user for each project. You
are not permitted to include spaces in the Project Code.
Project folders are created under a parent folder called the "Orion Data Directory". There can be more than one data folder
for grouping the different projects. You can use spaces in the “Orion Data Directories" however the program will prevent
you from using them in the “Project Directory”.
You can change the current Orion Data Folder by the "Data Directory" button on the "Project Manager" form.
The Setup procedure creates a subfolder, "TMP", under the Orion Data Directory for the temporary files created during
project modelling analysis. "TMP" folder can be relocated or renamed but it shouldn't be removed. You can use the "Scratch
Directory" button on the "Project Manager" to relocate the temporary files' folder.
If you press the "OK" button to close the "Project Manager" the selected project will be loaded to the Graphical Editor and
the parameters will be saved in a file named as the <project code>.pbp.
For example, project parameters file created for the ABC1 project will be named as "ABC1.PBP" and will be stored in [Orion
Data Folder]\ABC1\ABC1.PBP" folder.
New projects can be created either using the same project settings as a different project, or by using a Template of specific
settings.
An existing project will retain the project settings it had when it was last saved.
If you have an existing project with settings modified to your preference and you would like to apply those preferences to a
new project, simply select that existing project in the Settings Centre when creating the new project and Import the settings
you want. Alternatively, you could create a Template, also in the Settings Centre, which you could then apply to whichever
projects you like.
To revert to the default setting of the program, you can select one of the several default Templates available from the
Settings Centre.
sales@cscworld.com
www.cscworld.com
© CSC (UK) Limited 2011.
All Rights Reserved. Delivering: