Professional Documents
Culture Documents
Huawei GSM-R Bts3900A Hardware Structure: ISSUE4.0
Huawei GSM-R Bts3900A Hardware Structure: ISSUE4.0
ISSUE4.0
www.huawei.com
HUAWEI Confidential
The BTS3900A developed by Huawei is an outdoor macro
BTS that performs the same tasks as the BTS3900. The
BTS3900A mainly consists of the BBU and DRFUs. Compared
with traditional BTSs, the BTS3900A features simpler structure
and higher integration.
PSTN
MS TUP,ISUP ISDN
BTS3900A PSPDN
BSC
A Interface
MS MSC/VLR
MAP
BTS3900A
BTS HLR/AUC/EIR
SMC/VM
MS
BTS3900A OMC
MS: Mobile Station BTS: Base Transceiver Station BSC: Base Station Controller
HLR: Home Location Register AUC: Authentication Center EIR: Equipment Identity Register
MSC: Mobile Switching Center VLR: Visitor Location Register SMC: Short Message Center
VM: Voice Mailbox OMC: Operation and Maintenance Center DBS:Distributed Base Station
Page 10
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Outdoor IBBS200D/IBBS200T Ver.D
cabinet
Page 11
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
BTS3900A Local Structure
1 2
SW1 ON ON The E1 impedance is set to 75 Ω.
ON OFF ON OFF The E1 link of the Level 2 cascaded BTS can be bypassed.
OFF OFF ON OFF The E1 link of the Level 3 cascaded BTS can be bypassed.
ON ON OFF OFF The E1 link of the Level 4 cascaded BTS can be bypassed.
OFF ON OFF OFF The E1 link of the Level 5 cascaded BTS can be bypassed.
EXT-ALM0 RJ45
MON0 RJ45
EXT-ALM0 RJ45
MON0 RJ45
INSIDE DB25 male E1 transfer cable Transfers the four E1/T1 signals between the UELP
connector of the BBU and the GTMU
OUTSIDE DB26 male E1/T1 cables of Provides the input and output of the four E1/T1
connector the BBU signals between the BBU and the BSC
The UELP has one DIP switch, which is used to set the impedance on the
E1/T1 port. There are four DIP bits on the DIP switch.
DIP Switch DIP Status Description
1 2 3 4
S1 ON ON ON ON The E1 impedance is set to 75 ohms. The E1
is grounded (unbalanced mode).
OFF OFF OFF OFF Other modes
PMU (Power and Environment Monitoring Unit) module manages the power
supply and batteries. The DPMU is the core of the power monitoring system.
PSU (Power Supply Unit) module Converts the 220 V AC power into the -48 V
DC power.
Wiring unit is used to connect with 220VAC power input cable and connects the
cable from DCDU module.
Ports Function
RS232/RS422 Used in communication with the central processing unit.
port
Battery switch The battery switch has two control ports ON and OFF, which are used for
switching on and switching off the battery.
Press and hold the port ON for 5-10 seconds to switch on the battery.
Press and hold the port OFF for 5-10 seconds to switch off the battery.
Power supply Two power supply test holes -48V and 0V are available for measurement
test port through an ordinary multi-meter.
COM port Used in connection to the external signal transfer board.
(1) PMU Module (2) PSU Module (AC/DC) (3) Wiring Unit
SN Port Function
1 ALM Connecting the monitoring signal
cable between the AFMU and the
APMI
2 DC Connecting the DC power cable
INPUT of the AFMU
Page51
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
MRFUd Board
LEDs on the Board
Power SPARE2, SPARE1, BBU, Power ports supplying the 10 outputs of power
output port FAN, and RFU5-RFU0 to the BBU, MRFUd, and fan box
Power SPARE2, SPARE1, BBU, Power switch controlling the 10 outputs for the
switch FAN, and RFU5-RFU0 BBU, MRFUd, and fan box
Boolean The first group Dry contact connectors Extended Boolean ports
port (from left to right)
The second group Dry contact connectors
The third group Dry contact connectors Smoke sensor port, door status sensor port
The fourth group Dry contact connectors Water sensor ports
DRFU Topology
The BBU and MRFUd support multiple network topologies such as star, chain, and
ring topologies.
Only optical fiber can be used between MRFUd and BBU.