ScienceDirect
Article history: Haematology coulters are widely used in labs and hospitals in both diagnostic and treat-
Received 25 July 2012 ment affairs. The aim of this study is to evaluate the performance of haematology coulter
Accepted 27 November 2012 in comparison with the traditional manual method. Eighty blood samples obtained from
Available online 13 September 2013 adult albino rats were subjected to analysis in both methods. Results showed a significant
(p 0.05) elevation in values of red blood cells, haemoglobin and mean corpuscular hae-
Keywords: moglobin obtained from coulter compared to those of manual method, whereas monocytes
Haematology coulters count increased in coulter compared to manual method. No significant difference was
Haematology manual methods observed related to total white blood cells and its fractions. Indices of mean corpuscular
Complete blood picture volume, mean corpuscular haemoglobin concentration were not significant. In conclusion,
the efficiency of coulter is better than manual method.
Copyright 2013, Beni-Suef University. Production and hosting by Elsevier B.V. All rights reserved.
2314-8535/$ e see front matter Copyright 2013, Beni-Suef University. Production and hosting by Elsevier B.V. All rights reserved.
http://dx.doi.org/10.1016/j.bjbas.2013.09.004
32 b e n i - s u e f u n i v e r s i t y j o u r n a l o f b a s i c a n d a p p l i e d s c i e n c e s 2 ( 2 0 1 3 ) 3 1 e3 5
Fig. 2 e Comparing haemoglobin concentration between Fig. 4 e Comparing the number of WBCs between the
the automatic analyzer and manual method (Mean ± SR). automatic analyzer and manual method (Mean ± SE).
b e n i - s u e f u n i v e r s i t y j o u r n a l o f b a s i c a n d a p p l i e d s c i e n c e s 2 ( 2 0 1 3 ) 3 1 e3 5 33
The result obtained regarding the rate of the RBCs was sta-
tistically significant (p 0.05) when measured with the
Fig. 6 e Comparing the percentage for number of Fig. 9 e Comparing the mean corpuscular haemoglobin
lymphocyte between the automatic analyzer and manual concentration between the automatic analyzer and manual
method (Mean ± SR). method (Mean ± SE).
34 b e n i - s u e f u n i v e r s i t y j o u r n a l o f b a s i c a n d a p p l i e d s c i e n c e s 2 ( 2 0 1 3 ) 3 1 e3 5
Acknowledgement
references
Tan BT, Nva AJ, George TL. Evaluation of the Beckman coulter Timm K. Orital venous anatomy of the rats. Laboratory Animal
Unicel DxH 800, Beckman Coulter LH 780, and Abbort Science 1979;29(5):636e70.
Diagnostics Cell Sappire hematology analyzers adult Witko-Sarsat V, Rieu P, Descamps-Latscha B, Lesavre P,
specimens in a tertiary care hospital. American Journal of Halbwachs-Mecarelli L. Neutrophils: molecules, functions and
Clinical Pathology 2011;135(6):939e51. pathophysiological aspects. Laboratory Investigation
Thrall MA. Veterinary hematology and clinical chemistry; 2004. 2000;80(5):617e35.
p. 10e5.