1. ……. Conductor is widely used for High Voltage Overhead Transmission Lines.

ACSR Copper Iron


2. The Current Carrying Capacity of 1/18 Copper wire is…… Amp. 10 5 28
3. The specific resistance of Aluminium is …….. The specific resistance of Copper Equal to More than
Less than
4. …………. Conductor is used for High Voltage Overhead Transmission Line ACSR Aluminium Copper
5. The Current Carrying Capacity of 3/20 Wire is…….. The Current carrying Capacity of 3/22 More than
Equal to Less than
6. In a SWG the smallest size has the number………… 18 22 36
7. Heating Element of Toaster is made up of ……… Copper Nichrome Aluminium
8. ………….. is used to control temperature of Automatic Electric Iron. Regulator Thermostat
Pilot Lamp
9. The Electirc Iron operates on the principle of …….. Effect of Electirc Current. Heating Magnetic
Chemical
10. …………… is used to control temerature of Automatic Electric Iron. Resistor Thermostat Fuse
11. ……… is used to control temperature of an Automatic Electric Iron. Resistor Capacitor Thermostat
12. A Fan produces noise if……… its Windings are short circuited it is over Lubricated its bearing are
damaged
13. Fuse provides……… safety. Open circuit Only Overhead Both Overhead and short Circuit
14. Fuse is connected on………….. Wire Neutral Earth Phase
15. The Value of Fusing Factor is always …………. One More than Less than Equal to
16. The Value of Fusing Factor is always ………. One. less than more than equal to
17. …….. fuse unit allows a predetemined time to removed the short circuit Kit-Kat H.R.C. Cartridge
18. A fuse is a ……… Device. Controlling Protecting Holding
19. …………. is used as Fuse Element. Lead Tin Alloy Carbon Gold
20. To check insulation resistance between conductor and earth, in wiring installation…… is used. megger clip-
on meter synchroscope
21. To check the insulation resistance between Conductor and Earth in Wiring installation ……….. Is used.
Ohmmeter multimeter Megger
22. Neon Sign Tubes are used for …….. Purpose Domestic Street Lighting Advertising
23. The losses due to dust and dirt are taken into consideration be……….Utilization Factor Depreciation Factor

24. ………. Is used to improve power factor in HPMV Lamp. Choke Capacitor Transformer
25. Luminous Instensity of Carbon Filament Lamp is ……….. Tungesten Filament Lamp of same rating.
equal to less than greater than
26. Strobascopic Effect is caused by………… Fluorescent Lamp Carbon Filament lamp Metal Filament
Lamp
27. ………. Is most common material used for filament of lamps. Nichorme Tungsten Tantalum
28. Mercury Vapour Lamp are used for……….. Domestic Street Lighting Advertising
29. ………. lamp shows stroboscopic effect. Fluorescent Incandescent Are
30. L.T.Cables are used up to………….kv. 11 1 13.2
31. ………. Wiring is suitable for Blacksmith's Workshop. Cleat Wooden Casing and Capping Metal
Conduit
32. The leakage current of a wiring system is the ratio of voltage to…. Circuit current Load Resistance
Insulation Resistance
33. For temporary purpose……….wiring in used Metal conduit T.R.S. Cleat
34. Lead Alloy Sheathed wires are generally used for………..condition Climatic Wet Climatic Dry
Both
35. ………. Wiring is used in Workshop. Casing Capping Botten Metal Conduit
36. It is difficult to laocate fault in …………. Wiring System. cleat batten concealed conduit
37. The Labour Cost is maximum in………… Metal Conduit Wiring C.T.S. Wiring Cleat Wiring
38. The Conductors of VIR Wire are tinned because…….. by tinning the corrosion is restricted. by tinning
the rubber is prevented to stick up with the conductor and also avoids chemical reaction. the tinning
makes the conductor stronger and icreases its thickness to carry more current.
39. In industrial work………. Wiring system is used. cleat Casing-Capping Metal Conduit
40. …………. Wiring is used for workshop. CTS Conduit Casing Caping
41. Weather proof wires are used for ………. Wiring Outdoor Indoor Underground
42. ……… Wire is connected to the thick terminal of 3 Pin Plug socket. Phase Neutral Earth
43. In Three Phase Squirrel Cage Type Induction Motor the Starting Torque is ............. Running Torque
Equal to Less than Greater than
44. For 7.5H P. Motor................. starter is used. D.O.L Star-delta Rheustatic
45. The Speed of 3ø 8poles 50 hz synchronous motor will be ……R.P.M 750 1000 1500
46. The Rotor current Frequency of induction Motor…… with increase in speed Increases Decreases
Remains Same
47. The Rotor in Universal Motor is……….. Squirrel Cage Armature Wound Rotor
48. The windings in 3 phase induction motor are placed…….. Electrically a part from each other 180°
120° 360°
49. The slip speed of a 4-pole, 50Hz Synchronous Motor at its full speed is ……… 0 R.P.M. 50 R.P.M.
1500R.P.M.
50. In welding Work……………. Heating is used Resistance Arc Dielectiri
51. Iron Ores are melted quickly in ………….Furnace Indirect Arc Heating Core Type induction Heating
Direct Resistance Heating
52. …………. Heating is suitable for wood Processing Resistance Arc Di-electirc
53. Indirect Are Furnace is used for Melting........... Metals Steel Ferrous NonFerrous
54. Immersion Water Heater works on the basis of ......... Induction Heating Arc Heating Indirect
Resistance Heating
55. The Core Type induction Furnace can be used for heating ......... Non-metals Metals Metals and Non-
metals
56. A Moving Iron Instrument can be used to measure bóth A.C. and D.C. quantities. Say True /False

57. M.I. Type ammeter always reads……. Value of A.C.Current. Peak Average R.M.S.
58. ………. Is used as a Heating Element in Resistance Oven. Tungsten Nichrome Eureka
59. The range of ammeter is extended by connecting resistance across it (T/F)
60. ……… heating is not dependent on supply frequency. Resistance dielectirc Induction
61. A fuse wire of....................... is used for a motor which draws 12A. 25A 16A 18a
62. Synchronoscope is used for parallel operation of transformer alternator induction motor
63. ………… is used for parallel operation of 3 phase alternators Synchroscope Tong Tester Megger
64. …………… Motor has more starting torqure. Split Phase Capacacitor start shaded pole
65. ………type of 1ø motor is suitable for Electric Sewing Machine. Capacitor Start Shaded Pole Universal
66. Fault rectificatiion of 1ø motor comes under……….. Maintenance Preventive Break -down
Routine
67. The Capacitor in Capacitor start induction run motor is used to…….. improve power factor improve
speed improve starting torque
68. The frequency of rotor current f' is given by………….. f'=Sf f'=S/f f'=f/s
69. ………….. Synchronous motor runs on leading power factor. Under excited over excited 100%
excited
70. …………. Loss in a transformer is Constatnt. core copper friction
71. Shell Type Transformer has…………….. magnelic paths. one two three
72. Shell Type Transformer has ............. Three Magnetic Paths One Magnetic Path Two Magnetic Paths
73. Transformer works on the principle of........... Self Induction Mutual Induction None of these
74. Auto Transformer Starter is used for ...... ... Motors 5 H.P 10 H.P 20 H.P
75. if K > I. the transformer is said to be................................._ Step Down Isolation Step Up
76. the inductance of running winding is ................... than starting winding Less More Neither less nor
More
77. The Voltage regulation of the transformer will be low at P.F……… 0.45 0.25 0.87
78. ……… transformer has maximum magnetic paths. Core Shell Berry
79. C.T. is always……….. Type of Transformer. stepup Stepdown Either stepup of stepdown
80. Transformer transforms…………. From Primary to Secondary. Only Current Only Voltage Both
Voltage and Current
81. ………. Maintains Oil Level in Transformer Tank. Conservator Breather Oil Gauge
82. In a transformer e.m.f./turn in Primary Winding is …… e.m.f./turn is Secondary Winding. Less than
equal to more than
83. The Centrifugal Switch is connected in series with running winding. True/False
84. Core of Transformer is laminated to reduce ….. Losses. eddy current hystresis copper

ANSWERS

q. no answer
1 ACSR
2 5
3 MORE THAN CHECK
4 ACSR CHECK
5 MORE THAN
6 36
7 NICROME
8 THERMOSTAT CHECK
9 HEATING
10 THERMOSTAT
11 THERMOSTAT
12 BEARINGS DAMAGED
13 BOTH CHECK
14 PHASE
15 MORE THAN
16 MORE THAN
17 HRC
18 PROTECTING
19 LEAD TIN ALLOY
20 MEGGER
21 MEGGER
22 ADVERTISING
23 DEPRECIATION
24 CHOKE CHECK
25 LESS THAN CHECK
26 FLOUROSCENT
27 TUNGSTEN CHECK
28 STREET LIGHTING CHECK
29 FLOUROSCENT
30 1
31 CONDUIT WIRING
32 INSULATION RESISTANCE
33 CLEAT
34 CLIMATIC WET CHECK
35 CONDUIT WIRING
36 CONDUIT WIRING
37 CONDUIT WIRING CHECK
38 RUBBER PREVENTED FROM STICKING
39 CONDUIT WIRING
40 CONDUIT WIRING
41 OUTDOOR CHECK
42 EARTH
43 LESS THAN CHECK
44 CHECK
45 750
46 CHECK
47 CHECK
48 120
49 0 CHECK
50 arc CHECK
51 CHECK
52 dielectric
53 non ferrous
54 indirect resistance heating
55 metals
56 FALSE CHECK
57 rms CHECK
58 NICROME CHECK
59 TRUE
60 resistance
61 18A CHECK
62 alternators
63 synchroscope
64 capacitor start CHECK
65 universal
66 breakdown
67 starting torque CHECK
68 f'=sf
69 overexcited CHECK
70 core loss
71 2
72 2
73 mutual induction
74 CHECK
75 step up
76 CHECK
77 0.87
78 berry
79 step up
80 both voltage n current
81 conservator CHECK
82 equal to
83 FALSE
84 eddy current