You are on page 1of 1

PERSPECTIVE

TABLE OF CONTENTS
GENERAL ARCHITECTURAL STRUCTURAL ELECTRICAL MECHANICAL
G-1 BILL OF QUANTITIES A - 13 DETAIL BAY SECTION (ALONG TOILET) S - 11 DETAIL OF STAIR, RAMP DETAIL, DETAIL OF DC-1 PLAN & E-1 LOAD SCHEDULE, FLUORESCENT LIGHT FIXTURE
G-2 BILL OF QUANTITIES SECTION, DETAIL OF STAIR ON GRADE & DETAIL OF WALL ON
WP - 1 PARTIAL GROUND FLOOR (SHOWING LOCATION OF
DETAIL BAY SECTION (ALONG CORRIDOR) MOUNTING DETAIL, ELECTRICAL RISER DIAGRAM,
FTB CISTERN, PARTIAL ROOF PLAN, ELEVATION OF OVERHEAD
G-3 BILL OF QUANTITIES DETAIL PLAN & SECTION OF TOILET SINGLE LINE DIAGRAM, GENERAL NOTES AND
S - 12 STAIR FROM THIRD FLOOR TO DECK ROOF WATER TANK, ISOMETRIC DIAGRAM OF WATER PUMPING
G-4 BILL OF QUANTITIES A - 14 DETAIL PLAN & SECTION OF TOILET, LEGEND ( 12-CL )
SYSTEM, SCHEMATIC DIAGRAM OF WATER LEVEL
DETAIL OF COUNTER SINK E-2 LOAD SCHEDULE
G-5 BILL OF QUANTITIES
A - 15 BLACKBOARD DETAIL, CONNECTION SECTION PLUMBING E-3 POWER LAYOUT ( 12-CL )
CONTROL, LEGEND, SCHEDULE OF EQUIPMENT (12CL)
G-6 BILL OF QUANTITIES FP - 1 GROUND FLOOR, SECOND FLOOR & THIRD FLOOR
DETAIL, SECTION, SPOT DETAIL SECTION EDGE P-1 GEN. NOTES & LEGEND, MISC. DETAILS,TYP. SEPTIC E-4 LIGHTING LAYOUT ( 12-CL )
FIRE PROTECTION PLAN (12CL)
FRAMING, CHALK DUST BOX DETAIL TANK DETAIL, SEPTIC TANK DIMENSION, E-1 LOAD SCHEDULE, FLUORESCENT LIGHT FIXTURE
FP - 2 FIRE PROTECTION DETAIL, SCHEMATIC PIPING LAYOUT OF
ARCHITECTURAL UNDERGROUND WATER TANK DETAIL, MOUNTING DETAIL, PANEL BOARD DIAGRAM,
FIRE PROTECTION, GENERAL NOTES, LEGEND,
STRUCTURAL UNDERGROUND WATER TANK CAPACITY, SINGLE LINE DIAGRAM, GENERAL NOTES AND
TABULATED SPRINKLER HEADS OF THE AUTOMATIC FIRE
A-1 PERSPECTIVE, TABLE OF CONTENTS UNDERGROUND WATER TANK DIMENSION, ELEVATED LEGEND ( 15-CL )
SPRINKLER SYSTEM (12CL)
A-2 KEY PLAN S-1 GENERAL NOTES WATER TANK DIMENSION E-2 LOAD SCHEDULE
FP - 3 FIRE PROTECTION DETAIL, SCHED. OF EQUIPMENT (12CL)
A-3 GROUND FLOOR PLAN, SECOND FLOOR PLAN & S-2 GENERAL NOTES P-2 GROUND FLOOR SANITARY LINE LAYOUT TYPICAL E-3 POWER LAYOUT ( 15-CL )
WP - 1 PARTIAL GROUND FLOOR (SHOWING LOCATION OF
SCHEDULE OF FLOOR FINISH S-3 FOUNDATION PLAN, TYPICAL SECOND FLOOR & SECOND & THIRD FLOOR SANITARY LINE LAYOUT. E-4 LIGHTING LAYOUT ( 15-CL )
CISTERN, PARTIAL ROOF PLAN, ELEVATION OF OVERHEAD
A-4 THIRD FLOOR PLAN & FRONT ELEVATION THIRD FLOOR FRAMING PLAN P-3 ROOF STORM DRAINAGE LAYOUT
S-4 COLUMN SCHEDULE, SCHEDULE OF FOOTING,
WATER TANK, ISOMETRIC DIAGRAM OF WATER PUMPING
A-5 REAR, LEFT & RIGHT ELEVATIONS, CROSS SECTION P-4 GROUND FLOOR WATERLINE LAYOUT TYPICAL
A-6 LONGITUDINAL SECTION &GROUND FLOOR REFLECTED
SCHEDULE FOOTING BEAMS, TYPICAL FOOTING DETAIL,
SECOND & THIRD FLOOR WATERLINE LAYOUT.
MECHANICAL SYSTEM, SCHEMATIC DIAGRAM OF WATER LEVEL
ELEVATION OF COLUMN & DETAIL OF WALL FOOTINGS CONTROL, LEGEND, SCHEDULE OF EQUIPMENT (15CL)
CEILING PLAN S-5 SCHEDULE OF MAIN BEAMS, SCHEDULE OF SECONDARY
P-5 ROOF WATERLINE LAYOUT WP - 1 PARTIAL GROUND FLOOR (SHOWING LOCATION OF FP - 1 GROUND FLOOR, SECOND FLOOR & THIRD FLOOR
A-7 SECOND & THIRD FLOOR REFLECTED CEILING PLAN BEAMS, SCHEDULE OF SLABS, TYPICAL SLAB ELEVATION, P-6 WATERLINE ISOMETRIC VIEW CISTERN, PARTIAL ROOF PLAN, ELEVATION OF FIRE PROTECTION PLAN (15CL)
A-8 ROOF PLAN, SPOT DETAIL PLAN AND SECTION OF 1 2 & 3, TYPICAL BEAM DETAILS, TYPE OF STIRRUPS P-7 ISOMETRIC DIAGRAM (SEWER & DRAINAGE LAYOUT) OVERHEADWATER TANK, ISOMETRIC DIAGRAM FP - 2 FIRE PROTECTION DETAIL, SCHEMATIC PIPING
TYPICAL DETAIL OF DOOR FRAME, GLASS JALOUSIE TYPICAL S-6 ROOF FRAMING PLAN AT TOP CHORD & BOTTOM CHORD LEVEL OF WATER PUMPING SYSTEM, SCHEMATIC DIAGRAM LAYOUT OFFIRE PROTECTION, GENERAL NOTES, LEGEND,
DETAIL S-7 TRUSS DETAILS & CONNECTION DETAILS, SCHEDULE OF TRUSS ELECTRICAL
OF WATER LEVEL CONTROL, LEGEND, SCHEDULE TABULATED SPRINKLER HEADS OF THE AUTOMATIC FIRE
A-9 SCHEDULE OF DOORS & WINDOWS, DETAIL PLAN, ELEVATION & MEMBERS AND WELDS
OF EQUIPMENT (9CL) SPRINKLER SYSTEM (15CL)
SECTION OF RAMP, SPOT DETAILS & DETAIL OF WINDOW GRILL S-8 ELEV. OF END WALL FRAME, ELEV. OF END WALL FRAME & E-1 GENERAL NOTES, LEGEND, FLUORESCENT LIGHT
HALF TRUSS (GRID 2 &12), CONNECTION OF PURLINS TO RG-4, FP - 1 GROUND FLOOR, SECOND FLOOR & THIRD FLOOR FP - 3 FIRE PROTECTION DETAIL, SCHED. OF EQUIPMENT (15CL)
FOR W-2 FIXTURE MOUNTING DETAIL, LOAD SCHEDULE,
CONCRETE SUNBREAKER DETAIL, DETAIL SECTION OF PC-1 FIRE PROTECTION PLAN, FIRE PROTECTION DETAIL,
A - 10 SECTION DETAIL OF EAVES, SPOT DETAIL CORNER SINGLE LINE DIAGRAM AND ELECTRICAL RISER
S-9 DETAIL CONN. OF CROSS BRACING AT END WALL & TRUSS TABULATED SPRINKLER HEADS OF THE AUTOMATIC
CEILING, CONCRETE SUNBREAKER DETAIL, DIAGRAM ( 9-CL )
PLAN & SECTION, DET. OF PURLIN TO SAG ROD CONN. PLAN & FIRE SPRINKLER SYSTEM, GENERAL NOTES,
PERSPECTIVE, SECTION & SPOT DETAIL OF CEILING, SECTION, PURLIN CONN. DETAIL, PURLIN SPLICE
E-2 LOAD SCHEDULE
LEGEND (9CL)
PLAN & SECTION OF VENTILATION S - 10 TRUSS DETAIL AT GUTTER END, ANCHOR BOLT DETAIL, ROOF E-3 POWER LAYOUT ( 9-CL )
FP - 2 FIRE PROTECTION DETAIL, SCHEMATIC PIPING
A - 11 STAIR DETAILS, BALCONY RAILING DETAIL PANEL SIDE LAP DETAIL, J-BOLT SPACING, ROOFING FIXER, E-4 LIGHTING LAYOUT ( 9-CL )
LAYOUT OF FIRE PROTECTION, FIRE HOSE CABINET
A - 12 STAIR DETAIL TO DECK ROOF J-BOLT TO PURLIN & G.I. SHEET CONN. DETAIL
(FHC) DRY STAND PIPE RISER DIAGRAM CONN.,
SCHEDULE OF EQUIPMENT (9CL)
REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
ARMAN U. CUEVAS PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) BOD 7
STANDARD THREE-STOREY PERSPECTIVE,
ARCHITECTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING TABLE OF CONTENTS A-1
POSITION: ARCHITECT 63
PRC No.: 0018676 TIN No.: 907-359-364 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 15-CLASSROOMS )
PTR No.: 8941423 BUILDINGS DIVISION, BOD (REVISED 3-24-17)