Potential cause
Potential failure Potential effect of /mechanism of
Item mode failure SEV failure Occur
Function
Piston ring
Compression No end gap
1) Seal compression Leakage Power loss 7 desciption 6
High blow by No plating specs 6
Low tang. Force 7
Engine
Customer Tight crankshaft
1) Generate power Low power dissatisfaction 8 clearance 7
Air cleaner
capacity 6
Restricted fuel
supply 4
Current design Resp &
control preventation DET RPN Recommended action target date Action results
Action taken SEV OCC DET
Component Mention of end gap in Design dept.
supplier's standard 4 168 component drg. (10.11.2010) Doc updated
Drg. Updation for chrome
Supplier's specs 5 210 plating DO Doc updated
Force specs
FEA analysis and resulted defined in
NA 8 392 tang. Force on drg. DO drawing
Competitor engine
benchamarking 7 392 Drawing modifications DO Drg modified
CFD analysis and specs
Design calculations 5 240 modifications DO Drg modified
Filter replacement
None 3 96 schedule to be finalized. DO Drg modified
esults
RPN