You are on page 1of 29

MAKALAH TERMODINAMIKA

PEMICU 3
Power Generation and Refrigeration

Oleh Kelompok 1 :

Anwar Ismail (1706038380)


Merinda Innayah Fawwazita (1706038626)
Salsabella Rahmaputri Halim (1706985836)
Laily Fitri Pratiwi (1806154116)
M. Nizar Hamzah Al Faris (1806154116)

FAKULTAS TEKNIK

UNIVERSITAS INDONESIA

DEPOK

2019

1
DAFTAR ISI

Part 1: Rankine Cycle to Generate Electricity ............................................................................... 3


Part 2: Utilization of An LNG Revaporization Unit ..................................................................... 13
Part 3: What is the second law of thermodynamics ..................................................................... 15
Part 4: What is the second law of thermodynamics ..................................................................... 17
Part 5: Entropy Change in a turbine and a Throttling Valve ...................................................... 19
Part 6: Refrigeration ..................................................................................................................... 25

2
Part 1: Rankine Cycle to Generate Electricity

Gambar 1. Rankine Cycle Scheme


(sumber: pemicu)

Gambar 2. Working Fluid Path in A TS Diagram


(sumber: pemicu)
Having a textbook on Chemical Engineering thermodynamics you are confident that you will
learn the fundamentals of the Rankine cycle. What you need to do are as follows:

a. Explain what happen to the working fluid as it moves along the cycle; describe the
temperature, pressure, and phase (s) of each of the stream corresponding to figure (b)
above.
Using stream as your working fluid and the following data: saturate vapor enters the
turbine at 8.0 MPa, saturated liquid exits the condenser at 0.008 MPa, and, the net
power generated by the cycle is 100 MW. Determine the following quantities
assuming ideal Rankine cycle:

3
b. Thermal efficiency
c. Mass flow rate of the stream in kg/h
d. The rate of heat transfer, qin, into the working fluid as it flows through the boiler, in
MW
e. The rate of heat transfer, qout, from the condensed steam as it flows through the
condenser, in MW
f. The mass flow rate of condenser cooling water, in kg/h, if the cooling water entering
the condenser at 15 oC and leaves the condenser at 35 c
g. Repeat part b. except that the cycleis no longer an ideal cycle. Use efficiency value
for turbines and pumps
h. What can one do to increase the efficiency of the rankine cycle? Explain.

Jawaban:
a. 1-2 adalah proses pada pompa, working fluid dari tekanan rendah berubah
menjadi tekanan tinggi dan berfasa cair.
2-3 working fluid yang bertekanan tinggi masuk ke dalam boiler, kemudian
dipanaskan oleh sumber panas dari luar dan tekanan tetap. Fasenya berubah
menjadi saturated vapour.
3-4 saturated vapour masuk ke dalam turbine dan menghasilkan kerja.
Temperature dan tekanannya menurun, working fluid masih berfase gas namun
dapat terjadi sedikit kondensasi sehingga menjadi wet vapour
4-1 wet vapour masuk ke dalam condenser, lalu dikondensasikan menjadi
saturated liquid pada tekanan dan temperature tetap.
b. Asumsi
o Setiap siklus berlangsung pada steady state
o Proses berlangsung secara reversible
o Turbin dan pompa beroperasi secara adiabatic
o Energy kinetic dan potensial tidak berpengaruh signifikan

Dimulai dari inlet ke turbin, tekanannya adalah 8.0 MPa dan steam berbentuk saturated
vapor, dari table data kita dapatkan ℎ1 =2758.0 kJ/kg dan 𝑠1 = 5.7432 kJ/kg. K

4
State 2, 𝑝2 =0.008 MPa. Dengan menggunakan data saturated liquid dan saturated vapor, kita
dapat bahwa quality pada state 2 adalah

𝑠2 − 𝑠𝑓 5.7432 − 0.5926
𝑥2 = = = 0.6745
𝑠𝑔 − 𝑠𝑓 7.6361
Sehingga entalpinya
ℎ2 = ℎ𝑓 + 𝑋2 (ℎ𝑓𝑔 ) = 173.88 + (0.6745)2403.1 = 1794.8 𝑘𝐽/𝑘𝑔
State 3 adalah saturated liquid pada 0.008 MPa, jadi ℎ3 = 173.88 𝑘𝐽/𝑘𝑔
State 4, sama dengan tekanan 𝑝4 dan entropi spesifik 𝑠3 = 𝑠4 . ℎ4 dapat dicari dengan
menggunakan
𝑊̇𝑝
ℎ4 = ℎ3 + = ℎ3 + 𝑣3 (𝑝4 − 𝑝3 )
𝑚̇
Dengan memasukan data dari tabel maka diperoleh

−3 3
106 𝑁
173.88𝑘𝐽 10 𝑚 2 1 𝑘𝐽
ℎ4 = + (1.0084 𝑋 (8.0 − 0.008)𝑀𝑃𝑎 | 𝑚 | | 3 |
𝑘𝑔 𝑘𝑔 1 𝑀𝑃𝑎 10 𝑁. 𝑚

= 173.88 + 8.06 = 181.94 𝑘𝐽/𝑘𝑔


c. Thermal efficiency
𝑊̇𝑐𝑦𝑐𝑙𝑒 = 𝑊̇𝑡 − 𝑊̇𝑝

Kesetimbangan massa dan energi dengan control volume disekitar turbine dan pompa
diketahui :

𝑊̇𝑡 𝑊̇𝑝
= ℎ1 − ℎ2 = ℎ4 − ℎ 3
𝑚̇ 𝑚̇

Kalor pada saat di boiler yaitu :

𝑄̇𝑚
= ℎ1 − ℎ4
𝑚̇

Sehingga thermal efficiency :

𝑊̇𝑡 − 𝑊𝑝 (ℎ1 − ℎ2 ) − (ℎ4 − ℎ3 )


𝜂= =
𝑄̇𝑖𝑛 (ℎ1 − ℎ4 )
(2758 − 1794,8) − (181,94 − 173,88)𝑘𝑗/𝑘𝑔
=
(2758 − 181,94)𝑘𝑗/𝑘𝑔

5
= 0,371 = 37,1%

6
d. The mass flow rate of the steam, in kg/h
𝑊̇𝑐𝑦𝑐𝑙𝑒
𝑚̇ =
(ℎ1 − ℎ2 ) − (ℎ4 − ℎ3 )
(100𝑀𝑊)|103 𝑘𝑊/𝑀𝑊 ||3600𝑠/ℎ|
=
(963,2 − 8,06)𝑘𝑗/𝑘𝑔
= 3,77 . 105 𝑘𝑔/ℎ
e. The rate of heat transfer, qin,into the working fluid as it flows through the boiler,
in MW
𝑄̇𝑖𝑛 = 𝑚̇(ℎ1 − ℎ4 )
105 𝑘𝑔
(3,77 × ( )
ℎ ) 2758 − 181,94 𝑘𝑗/𝑘𝑔
=
|103 𝑘𝑊/𝑀𝑊 ||3600𝑠/ℎ|
= 269,77 𝑀𝑊
f. The rate of heat transfer, qout, from the condensed steam as it flows through the
condenser, in MW
𝑄̇𝑜𝑢𝑡 = 𝑚̇(ℎ2 − ℎ3 )
105 𝑘𝑔
(3,77 × ( )
ℎ ) 1794,8 − 173,88 𝑘𝑗/𝑘𝑔
=
|103 𝑘𝑊/𝑀𝑊 ||3600𝑠/ℎ|
= 169,75 𝑀𝑊
g. The mass flow rate of the condenser cooling water, in kg/h, if the cooling water
enters at 15O and leave the condenser at 35o
Pada kondensor terdapat control volume, sehingga massa dan energi balance pada
keadaan steady state yaitu :
0 = 𝑄̇𝑐𝑣 − 𝑊̇𝑐𝑣 + 𝑚̇𝑐𝑤 (ℎ𝑐𝑤,𝑖𝑛 − ℎ𝑐𝑤,𝑜𝑢𝑡 ) + 𝑚̇(ℎ2 − ℎ3 )
𝑚̇(ℎ2 − ℎ3 )
𝑚̇𝑐𝑤 =
(ℎ𝑐𝑤,𝑜𝑢𝑡 − ℎ𝑐𝑤,𝑖𝑛 )
Untuk cooling water, seperti yang diketahui nahwa entalpi fungsi dari suhu, jadi
dengan nilai entalpi saturated liquid yang dapat dilihat pada steam tabel ketika masuk
(15O )dan keluar ( 35o )
(169,75𝑀𝑊)|103 𝑘𝑊/𝑀𝑊 ||3600𝑠/ℎ|
𝑚̇𝑐𝑤 =
(146,68 − 62,99)𝑘𝑗/𝑘𝑔
= 7,3 × 106 𝑘𝑔/ℎ

7
g.
• Efesiensi termal
Diketahui
o ŋpump =0.75
o ŋturbine =0.75
o P3 =8.0 Mpa
o P1 =0.008 Mpa
o Wnet =100 MV

Asumsi;

o Setiap komponen pada siklus Rankine ditinjau dalam kondisi tunak


o Turbin dan pompa beroperasi secara adiabatik
o Semua proses dari fluida kerja bersifat irreversible
o Uap jenuh memasuki turbin dan kondensat keluar dari kondenser
sebagai cairan jenuh

Pertama kita akan meninjau sistem pompa dan turbin karena telah diketahui efisiensi
dari masing-masing sehingga akan memudahkan dalam pencarian kerja Rankine non-
ideal pada kedua unit tersebut. Dengan menggunakan steam table kita dapat mengisi;

𝑠4 − 𝑠𝑓
𝑋4𝑠 =
𝑠𝑔 − 𝑠𝑓
5.74 − 0.59
𝑋4𝑠 =
7.64

𝑋4𝑠 = 0.67
Sehingga,
ℎ4𝑠 = ℎ𝑓 + 𝑋4 (ℎ𝑓𝑔 )
ℎ4𝑠 = 173.88 + 0.67(2403.1)
ℎ4𝑠 = 1794.77 𝑘𝐽/𝑘𝑔
Setelah itu, kita harus mencari nilai dari kerja pompa dan turbin pada saat keadaan
non-ideal di mana kerja ini didapatkan dengan bantuan nilai efisiensi komponen, yaitu
perbandingan kerja ideal dan non-ideal pada pompa dan turbin

8
Kerja pada turbin
o Kondisi ideal
𝑊̇𝑡 = 𝑚̇(ℎ̇ 3 − ℎ4𝑠 )

̇
𝑊̇𝑡 = 𝑚̇(2758.6 − 1794.77)
𝑊̇𝑡 = 𝑚̇(963.83̇ )𝑘𝐽/𝑘𝑔
Kondisi non-ideal

𝑊̇𝑡 = 0.75̇ ̇ 𝑥 (𝑊̇𝑡 𝑖𝑑𝑒𝑎𝑙 )


𝑊̇𝑡 = 0.75 𝑥 (963.83)𝑥 𝑚̇
𝑊̇𝑡 = 𝑚̇ 𝑥 722.87 𝑘𝐽/𝑘𝑔
Kita harus membandingkan kerja pada turbin pada saat kondisi ideal dan non-ideal
untuk mendapatkan nilai entalpi keluaran turbin pada saat kondisi ideal

ṁ x 722.87 kj = ṁ(ℎ3 − ℎ4 )
722.87 𝑘𝑗 = (ℎ3 − ℎ4 )
ℎ4 = (2578.6 − 722.87)kj/kg
ℎ4 = 2035.73 𝑘𝑗/𝑘𝑔
Kerja pada pompa
Pada komponen pompa, kita harus mencari nilai entalpi pada saat fluida keluar dari
pompa terlebih dahulu untuk menentukan nilai kerja pompa pada saat kondisi ideal.
Kemudian kita dapat mencari nilai kerja pompa dan entalpi fluida keluar pompa pada
kondisi tidak ideal
ℎ2𝑠 = ℎ1 + (𝑃3 − 𝑃1 )𝑉𝑠

−3
𝑚3 106 𝑁/𝑚2 1𝑘𝑗
ℎ2𝑠 = 173.85 + (8 − 0.008)𝑀𝑃𝑎(1.0084 x 10 | || 3 |
𝑘𝑔 1𝑀𝑃𝑎 10 𝑁. 𝑚
ℎ2𝑠 = 181.91 𝑘𝐽/𝑘𝑔
Setelah mendapatkan h2 pada kondisi ideal, kita dapat menentukan nilai kerja pompa
pada kondisi ideal dengan menggunakan rumus

𝑊̇𝑝 = 𝑚̇(ℎ2𝑠 − ℎ1 )

9
𝑊̇𝑝 = 𝑚̇(181.91 − 173.85)𝑘𝐽/𝑘𝑔
𝑊̇𝑝 = 𝑚̇(8.06)𝑘𝐽/𝑘𝑔
Selanjutnya, kita mencari nilai kerja pada saat kondisi non-ideal, yaitu dengan
menggunakan efisiensi pompa,
𝑊̇ ̇ 𝑝 𝑖𝑑𝑒𝑎𝑙 )
(𝑊
𝑝 𝑛𝑜𝑛−𝑖𝑑𝑒𝑎𝑙=
0.75

𝑊̇ 𝑚̇ (8.06)𝑘𝐽
𝑘𝑔
𝑝 𝑛𝑜𝑛−𝑖𝑑𝑒𝑎𝑙=
0.75

Dari nilai kerja saat kondisi non-ideal ini, kita dapat mencari nilai entalpi fluida keluar
pompa saat kondisi non-ideal
̇
10.75𝑘𝐽
𝑚̇ 𝑥 = 𝑚(ℎ2 − ℎ1 )
𝑘𝑔
𝑘𝐽
ℎ2 = 173.85 + 10.75 𝑘𝐽/𝑘𝑔
𝑘𝑔
𝑘𝐽
ℎ2 = 184.6
𝑘𝑔

Tahap selanjutnya adalah mencari nilai dari 𝑄̇𝑖𝑛̇ dengan menggunakan rumus
𝑄̇𝑖𝑛 = 𝑚 𝑥 (ℎ3̇ − ℎ2 )
Dimana ℎ2 yang digunakan merupakan entalpi fluida keluar pompa pada keadaan non-
ideal sehingga
𝑄̇𝑖𝑛 = 𝑚̇ 𝑥 (2758.6 − 184.6)𝑘𝐽/𝑘𝑔
𝑄̇𝑖𝑛 = 𝑚̇ 𝑥 (2574 𝑘𝐽/𝑘𝑔)
Selanjutnya mencari nilai efisiensi termal dengan mengggunakan 𝑊̇𝑐𝑦𝑐𝑙𝑒 dan 𝑄̇𝑖𝑛
𝑊̇𝑐𝑦𝑐𝑙𝑒
ŋ𝑡𝑒𝑟𝑚𝑎𝑙 =
𝑄̇𝑖𝑛
Dimana
𝑊̇𝑐𝑦𝑐𝑙𝑒 = 𝑊𝑡 − 𝑊̇𝑝 = 𝑚̇[(ℎ3 − ℎ4 ) − (ℎ2 − ℎ1 )]

Dan
𝑄̇𝑖𝑛 = 𝑚̇ 𝑥 (ℎ3 − ℎ2 )

Sehingga,
𝑚̇[(ℎ3 − ℎ4 ) − (ℎ2 − ℎ1 )]
ŋ𝑡𝑒𝑟𝑚𝑎𝑙 =
𝑚̇ 𝑥 (ℎ3 − ℎ2 )

10
[(ℎ3 − ℎ4 ) − (ℎ2 − ℎ1 )]
ŋ𝑡𝑒𝑟𝑚𝑎𝑙 =
(ℎ3 − ℎ 2 )
[(278.56 − 2035.73) − (184.6 − 173.85)]𝑘𝐽/𝑘𝑔
ŋ𝑡𝑒𝑟𝑚𝑎𝑙 =
(2758.6 − 184.6)𝑘𝐽/𝑘𝑔
ŋ𝑡𝑒𝑟𝑚𝑎𝑙 = 0.28
• Mencari Mass Flow Rate
Dengan menggunakan ŋ𝑡𝑒𝑟𝑚𝑎𝑙 , 𝑊̇𝑐𝑦𝑐𝑙𝑒 , dan 𝑄̇𝑖𝑛 yang telah didapat.
𝑊̇𝑐𝑦𝑐𝑙𝑒
ŋ𝑡𝑒𝑟𝑚𝑎𝑙 =
𝑄̇𝑖𝑛
𝑊̇𝑐𝑦𝑐𝑙𝑒
𝑄̇𝑖𝑛 =
ŋ𝑡𝑒𝑟𝑚𝑎𝑙
𝑊̇𝑐𝑦𝑐𝑙𝑒
𝑄̇𝑖𝑛 =
ŋ𝑡𝑒𝑟𝑚𝑎𝑙
𝑊̇𝑐𝑦𝑐𝑙𝑒
𝑚̇(ℎ3 − ℎ2 ) =
ŋ𝑡𝑒𝑟𝑚𝑎𝑙
𝑚̇(2578.6 − 184.6)𝑘𝐽 (100 𝑀𝑊)|3600 𝑠/ℎ||103 𝑘𝑊/𝑀𝑊 |
=
𝑘𝑔 0.28
𝑚̇ = 5.5 𝑥 105 𝑘𝑔/ℎ

• Mencari rate of heat transfer yang masuk ke boiler


Nilai laju alir kalor yang masuk ke dalam boiler dapat dicari dengan menggunakan
entalpi pada kondisi 3 dan kondisi 2, yaitu pada saat aliran keluar dari boiler dan
aliran masuk boiler.
𝑄̇𝑖𝑛 = 𝑚̇ 𝑥 (ℎ3 − ℎ2 )
104 𝑘𝑔
5.5 𝑥 (2758.6 − 184.6)𝑘𝐽/𝑘𝑔
𝑄̇𝑖𝑛 = ℎ
3600𝑠 3
ℎ 𝑥 10 𝑘𝑊/𝑀𝑊
𝑄̇𝑖𝑛 = 357.5 𝑀𝑊
• Mencari rate of heat transfer yang keluar dari condenser (𝑄̇𝑜𝑢𝑡 )
𝑄̇𝑜𝑢𝑡 = 𝑚̇ 𝑥 (ℎ4 − ℎ1 )
104 𝑘𝑔
5.5 𝑥 (2035.73 − 173.85)𝑘𝐽/𝑘𝑔
𝑄̇𝑜𝑢𝑡 = ℎ
3600𝑠 3
ℎ 𝑥 10 𝑘𝑊/𝑀𝑊
𝑄̇𝑜𝑢𝑡 = 258.59 𝑀𝑊

11
• Nilai dari laju alir massa pada cooling water dalam condenser
Dengan mengasumsikan area di sekitar kondenser sebagai control volume maka
kita akan mendapatkan neraca energy
̇ ℎ1 )
0 = 𝑄̇𝑐𝑣 + 𝑊̇𝑐𝑣 + 𝑚̇𝑐𝑤 (ℎ𝑐𝑤,𝑖𝑛 − ℎ𝑐𝑤,𝑜𝑢𝑡 ) + 𝑚(ℎ4 −
Dimana 𝑚̇𝑐𝑤 adalah laju alir massa dari air dingin, dapat dicari dengan
𝑚̇𝑐𝑤 (ℎ𝑐𝑤,𝑜𝑢𝑡 − ℎ𝑐𝑤,𝑖𝑛 ) = 𝑚̇ (ℎ4 − ℎ1 )

Asumsi:
o ℎ𝑐𝑤,𝑜𝑢𝑡 adalah entalpi saat saturated water pada suhu 45 C, ℎ𝑐𝑤,𝑜𝑢𝑡 =
188.44 𝑘𝐽/𝑘𝑔
o ℎ𝑐𝑤,𝑖𝑛 adalah entalpi saat saturated water pada suhu 15 C, ℎ𝑐𝑤,𝑖𝑛 =
62.99 𝑘𝐽/𝑘𝑔
o diketahui 𝑚̇ = 5.5 𝑥 105 𝑘𝑔/ℎ

Sehingga
𝑚̇𝑐𝑤 (ℎ𝑐𝑤,𝑜𝑢𝑡 − ℎ𝑐𝑤,𝑖𝑛 ) = 𝑚̇ (ℎ4 − ℎ1 )
𝑚̇𝑐𝑤 (188.44 𝑘𝐽/𝑘𝑔 − 62.99 𝑘𝐽/𝑘𝑔 )
105 𝑘𝑔
= 5.5 𝑥 (2035.73 − 173.85)𝑘𝐽/𝑘𝑔

𝑚̇𝑐𝑤 = 0.7 𝑥 107 𝑘𝑔/ℎ
h. Menambah efisiensi
Untuk menambah efisiensi, tekanan dan suhu penguapan pada boiler
diperbesar. Dapat juga dengan melakukan superheating pada boiler. Tekanan
dan suhu yang tinggi pada boiler menyebabkan efisiensi yang juga tinggi.
Namun, untuk melakukan hal ini diperlukan konstruksi yang lebih berat dan
bahan konstruksi yang lebih mahal.

12
Part 2: Utilization of An LNG Revaporization Unit
After graduating with a degree in a chemical engineering you are working for PT Putra
Gasindo Gemilang (GPG) as a process engineer. PT GPG received a contract from an LNG
receiving terminal authority to evaluate the possibility of utilizing LNG cold energy for the
generation of electrical energy using the Rankine cycle. A short decription is given:

• LNG from LNG storage tank is pumped using LNG pump to pressure of 35-45 kgf/cm2
gauge.
• LNG flows through the first heat exchanger (propane vapor condenser) so that its
temperature is increased from -160 to -50 oC. Subsequently, LNG is evaporated in the
natural gas trim heater using sea water as the heating fluid.
• Once liquefied, propane as a working fluid in the Rankine cycle is pressurized by the
propane circulation pump and vaporized in the propane vaporizer at a pressure
corresponding to the temperature of the sea water. Propane vapor is expanded in the
turbine to produce electricity.
• Propane leaving the turbine enters the LNG vaporizer to liquefied again utilizing LNG
cold temperature.

Assignment:

1. Describe the Rankine cycle employed by Osaka Gas. Why is it called the low-temperature
Rankine cycle?
2. Estimate the conditions (temperature, pressure, phase) of the two fluids used in the low
temperature Rankine cycle.

Jawaban:

Gambar 3. Osaka Gas Process Flow Diagram 13

(sumber: https://www.osakagas.co.jp/en/rd/technical/1198907_6995.html)
1. Proses siklus Rankine pada Osaka Gas yaitu pertama, tekanan LNG dinaikkan
menjadi 35-45 kgf/cm2 oleh pompa LNG. LNG vaporizer mentransfer panas dari gas
propana ke LNG. LNG yang diuapkan kemudian memasuki trim heater NG dan
dipanaskan hingga 0ºC atau lebih tinggi oleh air laut. Selain itu, terdapat propana
digunakan sebagai Intermediate Heating Fluid (IHM). Propana cair yang
terkondensasi dalam LNG vaporizer melalui pertukaran panas dengan LNG tersebut
dipompa oleh pompa sirkulasi dan dikirim ke propana vaporizer di mana ia menguap
pada tekanan sesuai dengan suhu air laut. Gas propana yang diuapkan menggerakkan
turbin selama proses ekspansi dan menghasilkan energi listrik. Selanjutnya, gas
propana terkondensasi lagi dalam LNG vaporizer. Proses ini disebut siklus rankine
suhu rendah dikarenakan digunakan 2 working fluid yaitu propana yang memiliki titik
didih -42 oC serta LNG dengan titik didih -162 oC yang nilainya jauh lebih rendah
dibandingkan dengan air. Sistem ini disebut juga sebagai sistem pembangkit daya
kriogenik (suhu rendah).

2. LNG
Pada tangki, LNG disimpan dalam fasa liquid pada suhu -162oC dan tekanan 1 atm.
Kemudian, LNG fasa liquid dengan suhu yang sama tekanan dinaikkan menjadi 35-45
kgf/cm2 gauge setelah melalui pompa LNG dan suhunya naik hingga -155 oC. Lalu,
LNG vaporizer mentransfer panas dari gas propana ke LNG sehingga mengalami
perubahan fasa menjadi saturated vapor pada suhu -60oC. dengan tekanan yang sama
yaitu 35-45 kgf/cm2 gauge. LNG yang diuapkan kemudian memasuki trim heater NG
dan dipanaskan hingga 0ºC atau lebih tinggi oleh air laut sehingga fasanya telah
berubah menjadi uap yang kemudian akan ditransfer ke kota.
Propana

Gambar 4. Skema Sistem TCRC

14
(sumber: https://www.researchgate.net)

Gambar 5. Diagram T-s pada Sistem TCRC


(sumber: https://www.researchgate.net)

Berdasarkan skema dan diagram T-s sistem TCRC, Kedua aliran dari turbin yang
berbeda diperluas ke dua tekanan kondensasi yang berbeda. Propana yang masuk ke
dalam kondenser 1 mengalami kondensasi pada suhu -55oC dengan tekanan 8,22
lbf/in2 dan pada suhu -25oC serta tekanan 29,95 lbf/in2 dalam kondenser 2
(berdasarkan tabel propana dalam buku: Moran, M., Moran, M., Shapiro, H.,
Boettner, D. and Bailey, M. (2011). Fundamentals of engineering thermodynamics.
NJ: John Wiley & Sons.) dan mengalami perubahan fasa menjadi saturated liquid.
Kemudian melalui pompa dengan keadaan sama. Lalu propana masuk ke dalam
evaporator beserta air laut yang juga masuk pada suhu 20oC hal ini menyebabkan
terjadi perubahan fasa propana menjadi saturated vapor pada suhu 15oC dan tekanan
63,29 lbf/in2. Lalu propana melewati splitter dan terbentuk 2 aliran yang masuk ke
dalam turbin 1 dan 2. Uap propana menggerakkan turbin dan menghasilkan energi
listrik.

Part 3: What is the second law of thermodynamics? (Part a)

Hilda received an assignment from her thermodynamics course instructor who asked students
to derive the equation to calculate the efficiency of a Carnot engine:

𝑇
𝜂 = 1 - 𝑇𝐶
𝐻

Could you also do Hilda’s assignment? Hilda learned that the high temperature source could
be a combustion chamber where mixture of air and coal react and reach temperature of 700
K. What is the value of the Carnot engine efficiency calculated by Hilda? Explain why the

15
efficiency of the Carnot heat engine is higher than the typical efficiency value of an actual
heat angine (<0.4)?

Jawaban:

Gambar 6. Diagram PV siklus Carnot untuk gas ideal


(Sumber: Introduction to Chemical Engineering Thermodynamics 6 th Ed: J.M. Smith)

Dari gambar di atas dapat dilihat bahwa dalam siklus mesin Carnot, ada empat proses
reversibel yang terjadi, yaitu:

A – B : Pemampatan adiabatik karena suhu meningkat dari 𝑇𝐶 ke 𝑇𝐻 dan volume berkurang

B – C : Pemuaian isotermal karena menambahkan kalor dan volume bertambah

C – D : Pemuaian adiabatik karena temperatur turun sampai 𝑇𝐶 dan volume bertambah

D – A : Pemampatan isotermal dengn pelepasan kalor 𝑄𝐶

Diperoleh persamaan untuk proses dari B – C dan D – A:

ln 𝑉𝑐 ln 𝑉𝑑
𝑄ℎ = R𝑇𝐻 dan 𝑄𝐶 = R𝑇𝐻
𝑉𝑏 𝑉𝑎

Titik proses adiabatik A – B dan C – D diperoleh persamaan:

𝑇 𝐶𝑣 𝑑𝑇 𝑉𝑏 𝑇 𝐶𝑣 𝑑𝑇 𝑉𝑑
∫𝑇 𝐻 𝑅 𝑇
= ln
𝑉𝑎
dan ∫𝑇 𝐶
𝑅 𝑇
= ln
𝑉𝑐
𝐶 𝐻

𝑉𝑏 𝑇 1 𝑉𝑑 𝑇 1
ln = ∫𝑇 𝐻 𝑑𝑇 atau ln = ∫𝑇 𝐶 𝑑𝑇
𝑉𝑎 𝐶 𝑇 𝑉𝑐 𝐻 𝑇

𝑉𝑏 𝑇𝐻 𝑉𝑑 𝑇𝐶
ln = ln atau ln = ln
𝑉𝑎 𝑇𝐶 𝑉𝑐 𝑇𝐻

16
𝑉𝑎 𝑇𝐶 𝑉𝑑 𝑇𝐶
ln = ln atau ln = ln
𝑉𝑏 𝑇𝐻 𝑉𝑐 𝑇𝐻

Persamaan di atas dapat ditulis ulang menjadi:

𝑉
𝑄ℎ 𝑇ℎ ln𝑉 𝑐 𝑇ℎ
𝑏
= 𝑉𝑑 =
𝑄𝐶 𝑇𝑐 ln𝑉 𝑇𝑐
𝑎

Selisih antara kalor suhu 𝑇𝑐 diberikan dengan kalor 𝑇𝑐 dikeluarkan:

𝑇𝑐
W = (1 - ) 𝑄ℎ
𝑇ℎ

Efisiensi mesin dapat dihitung dengan persamaan:

𝑊 𝑇𝑐
𝜂= =1-
𝑄ℎ 𝑇ℎ

Nilai efisiensi saat suhu 700K:

𝑇𝑐 298
𝜂=1- =1- = 0,582
𝑇ℎ 700

Alasan mengapa efisiensi mesin Carnot lebih tinggi dibandingkan dengan efisiensi pada
umumnya karena pada sistem mesin Carnot memiliki empat proses reversibel pada saat
dioperasikan sehingga nilai efisiensi mesin Carnot adalah efisiensi keseluruhan atau
maksimum secara teoritis. Beberapa kalor yang diterima akan dilepaskan ke lingkungan yang
dapat digunakan sebagai reservoir suhu rendah sehingga saat beroperasi akan memiliki
kualitas yang lebih baik.

Part 4: What is the second law of thermodynamics? (Part b)

The Ranque-Hilsch vortex tube is a device that receives a gas stream (say at 10 bar and 295
K) and divides it into two streams with equal mass flow rates and equal pressure of 1 bar.
There is no mechanical work and heat transfer involved in the operation of this device. Show
by using the first and the second law of thermodynamics, that maximum temperature
difference between the two outlet streams is 501K. Hint: Largest temperature difference can
be obtained only if gas expansion is a reversible process. Assume ideal gas behaviour and use
Cp gas of 30 kJ/kmol.K.

17
Jawab:

Diketahui: 𝑚2 = 𝑚3
𝑇𝑖𝑛 = 𝑇𝑟𝑒𝑓 = 295K
𝑃𝑖𝑛(1) = 10 bar
𝑃𝑜𝑢𝑡(2) = 𝑃𝑜𝑢𝑡(3)
𝐶𝑝 = 30 kJ/kmol.K
𝑇2 - 𝑇3 = 501K

Asumsi: 𝑇2 = Suhu air panas dan 𝑇3 = Suhu air dingin, tidak ada kerja.

Berdasarkan Hukum Termodinamika I, neraca energi sistem:

∆𝑈 = Q – W

Karena tidak ada kerja, persamaan menjadi:

∆𝑈 = Q

Berdasarkan Hukum Kekekalan Energi, 𝐸𝑚𝑎𝑠𝑢𝑘 = 𝐸𝑘𝑒𝑙𝑢𝑎𝑟

𝑄𝑚𝑎𝑠𝑢𝑘 = 𝑄𝑘𝑒𝑙𝑢𝑎𝑟

𝑚1 𝐶𝑝 (𝑇1 - 𝑇𝑟𝑒𝑓 ) = 𝑚2 𝐶𝑝 (𝑇2 - 𝑇𝑟𝑒𝑓 ) + 𝑚3 𝐶𝑝 (𝑇3 - 𝑇𝑟𝑒𝑓 )

𝑚1 𝐶𝑝 (295-295) = 𝑚2 𝐶𝑝 (𝑇2 -295) + 𝑚3 𝐶𝑝 (𝑇3 -295)

𝑚1(295-295) = 𝑚2(𝑇2 -295) + 𝑚3(𝑇3 -295)

𝑇2 + 𝑇3 = 590

Hukum Termodinamika II:

∆𝑆 = ∆𝑆𝑠𝑖𝑠𝑡𝑒𝑚 + ∆𝑆𝑙𝑖𝑛𝑔𝑘𝑢𝑛𝑔𝑎𝑛

Karena perpindahan panas hanya terjadi di dalam sistem, maka ∆𝑆𝑙𝑖𝑛𝑔𝑘𝑢𝑛𝑔𝑎𝑛 tidak ada dan
proses reversibel maka ∆𝑆 = 0

0 = ∆𝑆𝑠𝑖𝑠𝑡𝑒𝑚

∆𝑆𝑠𝑖𝑠𝑡𝑒𝑚 = 𝑠2 + 𝑠3

18
Karena gas ideal

𝑇 𝑑𝑇 𝑃𝑓𝑖𝑛𝑎𝑙(2) 𝑇 𝑑𝑇 𝑃𝑓𝑖𝑛𝑎𝑙(3)
∆𝑆𝑠𝑖𝑠𝑡𝑒𝑚 = ∫𝑇 2 𝐶𝑝 (𝑇)( ) – R ln( ) + ∫𝑇 3 𝐶𝑝 (𝑇)( ) – R ln( )
𝑟𝑒𝑓 𝑇 𝑃𝑖𝑛𝑖𝑡𝑖𝑎𝑙 𝑟𝑒𝑓 𝑇 𝑃𝑖𝑛𝑖𝑡𝑖𝑎𝑙

𝑇 𝑑𝑇 𝑃𝑓𝑖𝑛𝑎𝑙(2) 𝑇 𝑑𝑇 𝑃𝑓𝑖𝑛𝑎𝑙(3)
0 = ∆𝑆𝑠𝑖𝑠𝑡𝑒𝑚 = ∫𝑇 2 𝐶𝑝 (𝑇)( ) – R ln( ) + ∫𝑇 3 𝐶𝑝 (𝑇)( ) – R ln( )
𝑟𝑒𝑓 𝑇 𝑃𝑖𝑛𝑖𝑡𝑖𝑎𝑙 𝑟𝑒𝑓 𝑇 𝑃𝑖𝑛𝑖𝑡𝑖𝑎𝑙

𝑇𝑓𝑖𝑛𝑎𝑙(2) 𝑃𝑓𝑖𝑛𝑎𝑙(2) 𝑇𝑓𝑖𝑛𝑎𝑙(3) 𝑃𝑓𝑖𝑛𝑎𝑙(3)


0 = 𝐶𝑝 ln( ) – R ln( ) + 𝐶𝑝 ln( ) – R ln( )
𝑇𝑖𝑛𝑖𝑡𝑖𝑎𝑙 𝑃𝑖𝑛𝑖𝑡𝑖𝑎𝑙 𝑇𝑖𝑛𝑖𝑡𝑖𝑎𝑙 𝑃𝑖𝑛𝑖𝑡𝑖𝑎𝑙

𝑘𝐽 𝑇2 𝑘𝐽 1 𝑘𝐽 𝑇3
0 = 30 ( )ln( ) – 8.315 ( ) ln( ) + 30( )ln( ) – 8.315
𝑘𝑚𝑜𝑙.𝐾 295 𝑘𝑚𝑜𝑙.𝐾 10 𝑘𝑚𝑜𝑙.𝐾 295
𝑘𝐽 1
( )ln( )
𝑘𝑚𝑜𝑙.𝐾 10

0 = 30 ln 𝑇2 – 30 ln 295 – ((8.315)(-2.302)) + 30 ln 𝑇3 – 30 ln 295 – ((8.315)


(-2.302)

30 ln(𝑇2. 𝑇3) = 302.92


302.92
(𝑇2. 𝑇3) = 𝑒 30

𝑇2 . 𝑇3 = 24343.001

𝑇3(501 + 𝑇3) = 24343.001

𝑇32 + 501𝑇3 – 24343.001 = 0

Dengan menggunakan rumus ABC

−𝑏±√𝑏2 −4𝑎𝑐
𝑇3(1,2) =
2𝑎

Sehingga diperoleh 𝑇2 = 545.6157K dan 𝑇3 = 44.6157K dengan menggunakan metode Goal


Seek.

Part 5: Entropy Change in a turbine and a Throttling Valve


Superheated steam at 40 bar and 360oC with mass flow rate of 11 kg/s is divided into two
streams. The first stream enters a 90% efficient steam turbine which produces 2.24 MW of
shaft work and the second stream enters a throttling valve. The stream exiting the valve and

19
the turbine mix in a mixing chamber and flows into a condenser where steam becomes
saturated liquid at 198.3oC. Determine:

A. The temperature of the stream leaving the mixing chamber;


B. The mass flow rate through the valve, in kg/s;
C. Locate the four numbered states on an h-s (enthalpy-entropy) diagram.

Neglect heat transfer with the surroundings, changes in kinetic and potential energy, and
pressure drop in mixing chamber and condenser.

Solution:

(1) (2)
Turbine
Mixing
(0) Chamber (5) (6)

Condenser

(3) (4)
Valve

Gambar 7. Diagram Alir

Asumsi Perhitungan:

➢ Sistem berada dalam kondisi steady-state


➢ Tidak terdapat perpindahan panas ke lingkungan
➢ Energi Kinetik dan Potensial diabaikan
➢ Tidak terdapat pressure drop pada pipa inlet mixing chamber dan kondenser

A. Temperatur keluaran mixing chamber


Untuk menentukan temperatur keluaran dari mixing chamber dilakukan penentuan
boundary dari sistem yang akan ditinjau pada proses ini. Penempatan boundary pada
proses aliran masuk dan keluar turbin, valve, dan mixing chamber sehingga dengan
menuliskan profil dan kondisi aliran massa dan energi diperoleh skema dibawah

Efisiensi = 0.9
W = 2.24 MW

Superheated Steam (1) (2) 20


P0 = 40 bar m5 = 11 kg/s
T0 = 360 oC Turbine Saturated Liquid
m1 = 11 kg/s T6 = 198.3 oC
Mixing
Chamber (5) (6)
Gambar 8. Boundary Layer Sistem
Dengan mengabaikan semua proses didalam boundary dapat diperoleh neraca energi
untuk boundary diatas adalah
𝑛 𝑛
∆𝑈 = 𝑄 − 𝑊 + ∑ (𝐻𝑖,𝑖𝑛 𝑥𝑚𝑖,𝑖𝑛 ) − ∑ (𝐻𝑖,𝑜𝑢𝑡 𝑥𝑚𝑖,𝑜𝑢𝑡 )
1 1
𝑛 𝑛
0 = 0 − 𝑊 + ∑ (𝐻𝑖,𝑖𝑛 𝑥𝑚𝑖,𝑖𝑛 ) − ∑ (𝐻𝑖,𝑜𝑢𝑡 𝑥𝑚𝑖,𝑜𝑢𝑡 )
1 1

Karena nilai laju alir massa yang masuk dan keluar boundary sama, maka
𝑛 𝑛
𝑊 = 𝑚 (∑ (𝐻𝑖,𝑖𝑛 ) − ∑ (𝐻𝑖,𝑜𝑢𝑡 ))
1 1

𝐽/𝑠 𝑘𝑔 𝑛 𝑛
2.24 𝑀𝑊 𝑥 106 ( ) = 11 ( ) (∑ (𝐻𝑖,𝑖𝑛 ) − ∑ (𝐻𝑖,𝑜𝑢𝑡 ))
𝑀𝑊 𝑠 1 1

Pada kondisi aliran masuk dimana superheated steam pada temperatur 360 oC dan
tekanan 40 bar dapat diperoleh nilai entalpi dari steam table

21
Tabel 1. Steam Table

(Sumber: Moran, M., Moran, M., Shapiro, H., Boettner, D. and Bailey, M. (2011). Fundamentals of
engineering thermodynamics. NJ: John Wiley & Sons.)
Sehingga entalpi keluaran dapat dihitung dan persamaan neraca massa menjadi
𝐽/𝑠 𝑘𝑔 𝐽 𝑛
2.24 𝑀𝑊 𝑥 106 ( ) = 11 ( ) (3117200 − ∑ (𝐻𝑖,𝑜𝑢𝑡 ))
𝑀𝑊 𝑠 𝑘𝑔 1
𝑛 𝑘𝐽
∑ (𝐻𝑖,𝑜𝑢𝑡 ) = 2913.56
1 𝑘𝑔
Karena pada turbin terdapat perubahan tekanan antara inlet dan outlet maka
penentuan kondisi tekanan keluaran sama dengan kondisi kondenser. Sehingga
dengan properti tersebut entalpi dan tekanan keluaran mixing chamber dapat
ditentukan temperaturnya. Pada kondisi output kondensor temperatur 198.3oC dengan
kondisi saturated liquid maka tekanannya dapat diperoleh dari steam table yaitu 15
bar. Dari data diatas maka temperatur keluaran mixing chamber dapat ditentukan
dengan entalpi 2913.56 kJ/kg dan tekanan 15 bar pada kondisi superheated steam.
Dengan interpolasi diperoleh
280 − 240 𝑇 − 240
=
2992.7 − 2899.3 2913.56 − 2899.3
𝑇 = 246.1 𝑜 𝐶

B. Laju alir massa ke throttling valve


Karena pada sistem diatas bekerja secara adiabatik dan reversibel sehingga sistem
tersebut juga akan berjalan dalam kondisi isentropik (nilai entropi konstan). Oleh

22
karena itu, nilai entropi pada titik 0 (aliran masuk) dan titik 1 (aliran masuk turbin)
akan bernilai sama. Nilai entropi dan entalpi ditentukan dari kondisi aliran tersebut
dimana temperatur 360 oC dan tekanan 40 bar, yaitu S0 = S1 = 6.6215 kJ/kg . K dan h0
= h1 = 3117.2 kJ/kg
Tabel 2. Steam Table

(Sumber: Moran, M., Moran, M., Shapiro, H., Boettner, D. and Bailey, M. (2011). Fundamentals of
engineering thermodynamics. NJ: John Wiley & Sons.)

Karena H2S adalah entalpi pada keluaran turbin maka karena kondisi isoterm namun
terjadi penurunan tekanan maka nilai entropi aktual dengan efisiensi turbin 0.9 dapat
ditentukan. Steam table digunakan untuk memperoleh data H1 dan H2S. Nilai H2
ditentukan menggunakan perhitungan efisiensi dengan persamaan
𝐻1 − 𝐻2
ƞ=
𝐻1 − 𝐻2𝑆
kJ
3117.2 kg − 𝐻2
0.9 =
kJ 𝑘𝐽
3117.2 − 2879.05
kg 𝑘𝑔
𝑘𝐽
𝐻2 = 2902.86
𝑘𝑔
Untuk mengetahui nilai aliran massa pada turbin digunakan persamaan neraca energi
turbin
𝑛 𝑛
𝑊 = 𝑚 (∑ (𝐻𝑖,𝑖𝑛 ) − ∑ (𝐻𝑖,𝑜𝑢𝑡 ))
1 1

𝑘𝐽 kJ 𝑘𝐽
2240 = 𝑚𝑡𝑢𝑟𝑏𝑖𝑛 (3117.2 − 2902.86 )
𝑠 kg 𝑘𝑔
𝑚𝑡𝑢𝑟𝑏𝑖𝑛 = 10.45 𝑘𝑔/𝑠
𝑘𝑔 𝑘𝑔 𝑘𝑔
𝑚𝑣𝑎𝑙𝑣𝑒 = 11 − 10.45 = 0.45
𝑠 𝑠 𝑠

23
C. Menentukan posisi pada h-s diagram
Pada penentuan posisi untuk setiap aliran proses pada h-s diagram diperlukan seluruh
data kondisi baik temperatur, tekanan dan fasa. Setelah dilakukan rekap untuk setiap
kondisi pada masing-masing tahap dilakukan plot pada diagram h-s.

Tabel 3. Data Aliran

Data Aliran
Nomor Temperatur Tekanan Entalpi Entropi
Fasa
Aliran (oC) (bar) (kJ/kg) (kJ/kg.S)
0 360 40 3117.2 6.6215 Superheated Steam
1 360 40 3117.2 6.6215 Superheated Steam
2 246.1 15 2913.56 6.6706 Superheated Steam
3 360 40 3117.2 6.6215 Superheated Steam
4 336.26 15 3118.1 7.055 Superhated steam
5 246.1 15 2913.56 6.6706 Superhated steam
6 198.3 15 844.74 2.3147 Saturated Liquid

Aliran 0, 1, 3
Aliran 4

Aliran 2, 5
Aliran 6

Gambar 9. H-S Diagram


(sumber: engineeringtoolbox.com)

24
Part 6: Refrigeration
Air Conditioner (AC) nowadays uses R-134a, the refrigerant replacing the not-so-
environmentally friendly R-12. An air conditioner with “AsalDinGin” brand having a
capacity of 1 PK has a cooling capacity of 9000 BTU/h. Estimate the mass flow rate of the
refrigerant and estimate the coefficient of performance of the AC. Write down all the
assumptions that you use (try to be as close as possible to the real-life condition). If
refrigerant R-134a is replaced with one of the three following hydrocarbons: ethane, propane,
and butane; which one will you choose as the working fluid to replace R-134a? Explain your
reasons from the thermodynamics point of view.

Ditanya : Estimasikan
a) Mass flow rate of the refrigerant (m/t)
b) Coefficient of performance (COPR)
c) Which one will you choose as the working fluid to replace R-134a? (ethane, propane,
and butane)

Diketahui :
• Cooling capacity = 9000 BTU/h = 216000 BTU/24h
• 1 PK = 0.986 HP = 735.5 Kw

Asumsi :

Suhu ruang yang dijaga di dalam ruangan = 16oC


Suhu keluaran AC di luar ruangan = 36oC
T evaporator dan T kondensor = 12oC
Steady state

Jawaban :

TC = 16oC - 12oC = 4oC


TH = 36oC + 12oC = 48oC
𝐵𝑇𝑈 𝑊
𝑄̇𝐿 = 9000 ℎ 𝑋 0.293 𝐵𝑇𝑈 = 2637 𝑊

h1 = h4

𝑘𝐽
ℎ − ℎ𝑓 118.35 −55.35 𝑘𝐽/𝑘𝑔
𝑘𝑔
X4 = ℎ𝑓𝑔
= 194.19 𝑘𝐽/𝑘𝑔
; X4 = 0.324

25
Gambar 10. Siklus Refrigerasi
(Sumber: Moran, M., Moran, M., Shapiro, H., Boettner, D. and Bailey, M.
(2011). Fundamentals of engineering thermodynamics. NJ: John Wiley & Sons.)

State P (kPa) T (K) h (kJ/kg) s (kJ/kg) X


(quality)

1 337.65 277.15 249.53 0.9169 1

2 1252.6 271.68 0.9169

3 1252.6 321.15 118.35 0.4243 0

4 337.65 277.15 118.35 0.324

a) Ẇ = ṁ (h3 – h2)
735.5 kW = ṁ (271.68 kJ/kg – 249.53 kJ/kg)
ṁ = 33.21 kg/s
𝑄̇ 2637 𝑊
b) COPR = Ẇ𝐿 = 735.5 𝑊 = 3.586
𝐶

𝑇𝑒𝑣𝑎𝑝 𝑇𝐶 277.15 𝐾
COPcarnott = 𝑇𝑘𝑜𝑛𝑑−𝑇𝑒𝑣𝑎𝑝 = = 321.15 𝐾−277.15 𝐾 = 6.299
𝑇𝐻 −𝑇𝐶

26
c)

Refrigerant Global Warming Flammable Critical Point


Potential (100 (oC) (oC)
years)

R-134a 1430 754 101

Etana 6 540 32

Propana 10 493 97

Butana 10 405 152

How to select refrigerants:

1. Have high latent heat of vaporization (can absorb big amount of heat)
2. Shouldn’t have high condensing pressure (economical reason, increase wear and tear
of device)
3. Freezing temperature of refrigerant should be below evaporation temperature => solid
states made system unable to function as a cycle
4. It should have sufficient high critical temperature => that won’t be reached during
refrigeration cycle
5. Refrigerant should be non-toxic, non-corrosive, and chemically stable
6. It should be easy to detect leaks
7. Cost of refrigerant should be low
Gambar 11. Refrigerant Options to Replace HFCs

27
Gambar 12. Holistic Approach to Refrigerant Selection

So, we think there is no reason to change refrigerant R-134a to hydrocarbons (ethane,


propane, butane) as refrigerant due to some reasons. Even GWP hydrocarbon is so much
lower than R-134a (<10), but for the system cost and safety for hydrocarbons (highly
flammable properties) are really far from we expected. Compressor design & cost energy
efficiency are slightly higher than R-134a. The refrigerant cost for the hydrocarbons and R-
134a is relatively the same.

Gambar 13. Refrigerant Safety Groups

28
DAFTAR PUSTAKA

Moran, M., Moran, M., Shapiro, H., Boettner, D. and Bailey, M. (2011). Fundamentals of
engineering thermodynamics. NJ: John Wiley & Sons.

Introduction to Chemical Engineering Thermodynamics 6th Ed: J.M. Smith

Anon, (2018). [online] Available at:


https://www.researchgate.net/publication/328798163_Organic_Rankine_Cycle_for_R
ecovery_of_Liquefied_Natural_Gas_LNG_Cold_Energy [Accessed 7 Apr. 2019 ].

29

You might also like