Today, modern production processes cannot be
imagined without compressed air as a versatile and
reliable energy source.
Depending on the respective single case different de-
mands are made on compressed air. Meeting a certain
moisture degree or dew point/pressure dew point is the
basis for a permanent failure-free plants operation.
CS Instruments GmbH has developed a pressure dew
point multifunction measuring instrument DS 400 with
lots of new advantages specially for moisture measure-
ment resp. dew point/pressure dew point measurement
in compressed air and gases.

60 www.cs-instruments.com
Dew point

WOLFGANG BLESSING
Usually compressed air is made from ‡ Hygroscopic products (spices, su-
ambient air by using piston or screw gar and so on) agglutinate during
compressors and which then has to transportation through the pneu-
be dried more or less strongly. matic conveying system

The aim is to produce dry, oil-free ‡ Bubbles occur during varnishing


and dust particle poor compressed and coating processes
air with the smallest possible efforts.
Residual oil and dust particles can ‡ Drilled holes may get blocked due
be removed by means of complex to dust which is carried along
filter systems. However, moisture
has to be reduced by means of dry- ‡ In winter controle valves freeze in
ers (refrigeration dryers, membrane unheated halls
dryers, adsorption dryers and so on)
which ideally work independent from Effects of the moisture content
any load.
Depending on the application dif-
How does water get into com- ferent demands are made on the
pressed air? compressed air. For each process
the observance of a certain moisture
Air is able to bind more water vapour content is the condition for a durably
if the temperature is higher and failure-free functioning of the whole
the volume is bigger. In contrary system. Most of the compressed air
case it has only a poor capacity to lines are made from steel or non
bind water vapour if the air is com- zinc-coated steel. Since the corrosi-
pressed. A compressor compres- on speed stronlgy increases from a
ses atmospheric ambient air into relative humidity of 50 % this value Tasks of dryers
a fraction of its original volume. At should be exceeded in no case. In
a certain point of the compression the course of time, high moisture will Differenty types of dryers are used
process the water content of the air lead to a corrosion in case of non in practice in order to control the
exceeds the decreasing ability of the zinc-coated lines. The rust gradually problems of too high moisture. In
air to bind water. The air is saturated chips off and moves to the sampling compressed air technology the
and part of the water drops out as points. This leads e. g. to blocked pressure dew point is the para-
condensate. By means of an addi- nozzles, defective control elements meter for indicating the dryness of
tional decrease of the temperature and production stops. compressed air. The pressure dew
even more water will condensate. point is the temperature at which the
This means that the relative humi- Expensive repairs and short mainte- moisture which is contained in the
dity at the end of a compressor will nance intervals are inevitable. compressed air condenses to liquid
always be at 100 % and that there water (also saturation, 100 % relative
will be additional water drops in the In addition to problems with corro- humidity). The lower the pressure
exit air. The amount of liquid which sion and the described results the dew point temperature the smaller is
drops out under pressure can be moisture content has direct influence the amount of water vapour contai-
large. For example a 30 kW com- on the quality of the final products. ned in the compresed air.
pressor releases approximately 20 Which problems may arise in case
litres into the compressed air line at of too high moisture? In the following Refrigeration dryers for dew point
a humidity of 60 % and an ambient please find some of the most occu- values around + 2 °Ctd
temperature of 20 °C. In case of big ring samples:
compressors this value will be much
higher.

www.cs-instruments.com 61
Dew point

There are different types of com- ‡ Condensate in the refrigeration the operation air.
pressed air dryers; refrigeration dry- dryer is not drained off (conden-
ers or adsorption dryers are the most sate drain defective resp. soiled) Depending on the procedure and the
commonly used ones. Refrigeration operating conditions the desiccant
dryers cool down the compressed ‡ Compressed air bypass in the has to be exchanged in cycles of
air to approximately 2 to 5 °C. In this refrigeration dryer (heat ex- three to five years.
case the pressure dew point is also changer pipes worn out, corro-
2 to 5 °C. The excess water vapour ded and so on) Certain operating conditions lead to
condenses and drops out. a shortening of the life span of the
‡ Compressed air bypass in the
desiccant:
bypass line (wet compressed air
After that the air is again heated up
passes the bypass instead of
to room temperature.
passing the dryer)
In most cases the refrigeration dryers ‡ Condensate overload of the
are only monitored by an indication refrigeration dryer due to poor
of the cooling temperature. Up to condensate pre-separation
now stationary moisture monitoring
systems are only installed in big If the refrigeration dryer fails this
plants resp. in case of particularly inevitably leads to considerable pro-
important applications. blems with condensate in the com-
pressed air line. It is especially pro-
However, it is not sufficient if only the blematic (besides the already listed
cooling temperature is indicated. The problems) if the condensate can
following failures my lead to an exa- concentrate in blind lines and does
ggerated pressure dew point even if not drain automatically.
the cooling temperature seems to be
alright: Condensate in blind lines can only
be removed by means of conside-
rable efforts or dried and drained
off by means of an extremely large ‡ Overload due to too big com-
amount of compressed air.This often pressed air consumption
leads to increased dew point values
at very low consumptions without ‡ Poor pre-separation of conden-
any evidable problems of the refri- sate
geration dryer. In this case it is quite
difficult for the person who is respon- ‡ Oily air
sible for compressed air to find out
in the long-term the reason for the ‡ Too long regeneration times of
increased dew point values or in the the single tanks
extreme case for the condensate
New: DS400 dew point measure-
Adsorption dryers for typical dew ment with alarm grants process
points around -30...-40°Ctd safety

The functioning of the adsorption For a safe process procedure it is


dryer is based on the principle of the necessary to monitor the demanded
attraction between the two masses. pressure dew points at any time and
Water vapour is bound (adsorbed) at to get an alarm in case of excee-
the surface of a desiccant. dings of the threshold values.

Effective adsorption dryers are able Weltweit einzigartig mit 3,5 Zoll
to dry compressed air down to a dew Graphik Display mit Touchscreen und
oint of -40°C and lower. Printfunktion

Regenerative adsorption dryers exist DS 400 dew point set


of two tanks which are filled with
desiccant. In different procedures Worldwide unique with 3.5 inch gra-
there is one tank regenerated cold phic display with touch screen and
resp. warm while the other one dries print function

62 www.cs-instruments.com
Dew point

The measuring chamber can be Special features:


connected to the sampling point wit-
‡ 3.5“ graphic display, intuitive ope-
hout any large installation efforts by
ration via touch screen
means of the standard plug nipple
for compressed air lines. ‡ Zoom function for accurate analy-
sis of measured values
The big difference to customa- ‡ Coloured measured curves with
ry paperless chart recorders is names
reflected in the simplicity of DS 400 ‡ Mathematical calculation function
on initiation and evaluation of the for calculation of the dew
With the new ”ready for plug-in” measured data.
‡ point distance (condensate switch)

DS 400 dew point sets for refrigera- The intuitive operation with the 3.5 ‡ Print key: Optional indications can
tion dryers as well as for membrane/ inch touch screen graphic display be stored as image
adsorption dryers down to -80 °Ctd with zoom function and print key is ‡ ¿OHVGLUHFWO\RQD86%VWLFNDQG
can be monitored easily and safely. worldwide unique in this price sent by e-mail
The dew point sets will be supplied class.
completely wired, therefore a time ‡ without any software
consuming studying of the instruction By means of the graphic display with ‡ 2 alarm contacts for exceedings of
manual is not necessary. threshold values
zoom function the drying procedure
Exceeding of threshold values can resp. the dew point curve can be ‡ Freely adjustable alarm delay for
be reported optically and acoustical- seen at a glance and stored in the both alarm contacts with reset
ly. 2 relays for pre- and main alarm data logger. function
are freely adjustable. ‡ Up to 4 sensor inputs for: Further
So the user can take a look at the ÀRZVHQVRUVGHZSRLQWSUHVVXUH
An alarm delay can be set for stored measuring curves also without temperature, consumption, active
each relay. This grants that only any computer at any time on site. power meters, optional third-
really long-term exceedings of the This grants a quick and easy analy- party sensors can be connected:
threshold values are indicated. Pt100/1000, 0/4..20 mA, 0-1/10 V,
sis of the drying behaviour.
Additionally every alarm can be Modbus, pulse
reset.
By means of the print key the actual ‡ Integrated data logger 2 GB
The dew point set DS 400 consists screen can be stored as an image ‡ USB, Ethernet interface, RS 485
of the multifunction measuring instru- file to the internal SD card or to a
ment DS 400 and the dew point USB stick and printed out at the ‡ Webserver
sensor FA 410 including measuring computer without any additional soft-
chamber for pressure dew point ware.
measurement of compressed air
and gases up to 16/50/350 bar. For Ideal for documentation of the
pressures of more than 16 bar plea- measured values/ curves on site.
se use the high-pressure measuring Coloured measured curves can be In case of any enquiries or
chamber. sent by e-mail as image files or questions please contact:
The heart of the dew point sensor integrated into a service report.
is the worldwide proven humidity
sensor of CS Instruments GmbH.
SALES OFFICE SOUTH
The internal data logger enables the
In order to get quick and accurate CS INSTRUMENTS GmbH
storage of the measured data for
measurements it is necessary that several years. The measured data
Zindelsteiner Straße 15
the humidity sensor is continuously can be evaluated via a USB stick or 78052 VS-Tannheim
flown by the gas (compressed air) via Ethernet by means of the comfor- Fon: +49 (0) 7705 978 99-0
to be measured. For this purpose a table software CS Soft Basic. Fax: +49 (0) 7705 978 99-20
defined volume flow is blown out at a info@cs-instruments.com
certain pressure via a capillary line. www.cs-instruments.com