You are on page 1of 81

AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

TUTORIAL
FOR DESIGN
OF A G+10
BUILDING
USING ETABS

BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Contents

1. Introduction.............................................................................................................................................. 1
2. Modelling and Analysis......................................................................................................................... 2
2.1. Create a New Model ...................................................................................................................... 5
2.2. Define Materials............................................................................................................................12
2.3. Define Sections .............................................................................................................................14
2.4. Add Geometry to the Model ......................................................................................................21
2.5. Meshing and Assigning Diaphragm ....................................................................................... 34
2.6. Define Load Cases and Load Combinations........................................................................39
2.7. Assign Loads..................................................................................................................................46
2.8. Assign Pier Labels ........................................................................................................................ 50
2.9. Define Mass Source and Autoline Constraints ....................................................................51
2.10. Assign the Supports .....................................................................................................................53
2.11. Check the Model and Run Analysis ........................................................................................ 54
3. Display the Results...............................................................................................................................56
3.1. Tabular Display.............................................................................................................................56
3.2. Graphical Display ......................................................................................................................... 60
4. Section Design .......................................................................................................................................65
4.1. Concrete Frame Design .............................................................................................................. 65
4.2. Shear Wall Design ........................................................................................................................ 69
5. Miscellaneous ........................................................................................................................................73
5.1. Section Designer ...........................................................................................................................73
5.2. Curved Beams................................................................................................................................78

BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

1. Introduction
The use of software for analysis and design of civil engineering structures has become
indispensable part of many of the complex civil engineering projects. Even though the
available software for analysis and design are intended to provide their utmost
simplicity, supplementary documents to understand the execution of the analysis and
design process may still be crucial. Thus, this tutorial is intended to provide a
comprehensive procedure about how to analyze and design reinforced concrete
buildings using ETABS. Particularly, designers who are novice for this software will be
entertained by this tutorial.

The tutorial is comprised of four additional main parts besides this introductory part.
To show the procedures, architectural floor plans of a G+10 building will be used. The
plans may not be exquisite from architectural point of view but they are still very useful
to utilize it for understanding the basic ETABS procedures.

The modelling and analysis part covers the all the procedures to create and analyze the
building by creating the ETABS model. This includes the procedures about creating a
new model, defining materials and sections. After adding the geometry to the model,
additional steps which supplement the complete modelling process will be outlined.
The final stage of this part will include topics about how to check the model and run
the analysis.

The second part of the tutorial is about displaying the analysis results. In this part, it
will be tried to include different procedures to display the analysis results.

The section design part shows how to design concrete frame and shear wall sections
using ETABS. The results of ETABS section design may not be strictly followed due
to possible building code differences, but they can be helpful to check section designs
by other conventional methods.

The last part of the tutorial, which is open for further development, includes
miscellaneous topics. In this part, ETABS procedures which were not discussed in the
previous parts and which might be important in modelling other types buildings will be
included.

Overall, the tutorial includes the very basic ETABS procedures about how to carry out
the analysis and design of a reinforced concrete building and more. Thus, it can be
useful for understanding the ETABS software.

1 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

2. Modelling and Analysis


In this part of the tutorial, an architectural plan and the input parameters will be given.
Then, the step-by-step procedures to create and analyze the model will be followed.

2 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

3 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

The story heights are:


- Foundation column height – 2m
- Ground floor story height – 4m
- Other (Typical story) heights – 3m

4 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

The section dimensions for columns, beams and shear walls are obtained from the
architectural plan. For slabs, the thickness is obtained from deflection requirement. The
sections for different structural parts are summarized as below:
Columns: Ground floor up to fifth floor Sixth floor up to roof
Circular – 500mm diameter Circular – 400mm diameter
Rectangular – 400X800mm Rectangular – 300X600mm
Beams: Ground floor up to fifth floor Sixth floor up to roof
Rectangular – 300X500mm Rectangular – 250X400mm
Intermediate beams (For all floors)
Rectangular – 250X400mm
Shear Wall: For all floors
Thickness = 300mm
Slab : For all floors
Thickness = 230mm

There is a live load of 3kN/m2 on all slabs and internal beams from the first floor to
the fifth floor. From the sixth to the tenth floor slabs, internal beams and on all stairs
and landings, there is a live load of 5kN/m2. Beams supporting external walls for all
floors except the roof floor are subjected to no live load but there is a wall load of
10kN/m. All the slabs and beams on the roof floor are subjected to a live load of
1kN/m2.

The concrete and steel grades which will be used for the design of the whole building
are:
Concrete – C-30 (30MPa 28 day characteristic cube strength)
Steel – S-400 (400MPa characteristic yield strength)

The class of works is class-I. The multi-purpose building will be founded on black
cotton soil is going to be constructed in coastal earthquake prone area.
2.1. Create a New Model

First, open the ETABS program from an appropriate location. Before creating the
model, the units which will be used for the design should be set. This is done by
selecting a suitable unit from the drop down menu at the bottom right corner of the
ETABS window.

5 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 1.
For this design, we will use ‘KN-m’ units and select this unit from the list of units in
the drop down menu.

To create a new model from the program, there are three ways.
a. Go to File >New Model …
b. Click on the icon . This icon is the first among the list of icons
just below the menu bar.
c. Simply click on the Ctrl and N keys simultaneously (Ctrl+N).
Performing one of the above three ways results in the popping-up of the following
‘New Model Initialization’ window.

Figure 2
This window helps you to choose an initialization method. Select one of the following:
• ‘Choose .edb’ button. When this button is clicked, ETABS displays the Open
File form. Use that form to select a previously created ETABS file that has an
.edb extension and that can be used as the basis for initializing the new model
using its definitions and preferences. After a file has been selected on the Open
File form, ETABS will display the Building Plan Grid System and Story Data
Definition form.
6 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

• ‘Default.edb’ button. This method is similar to the ‘Choose.edb’ method,


except that file selection happens automatically. That is, ETABS first attempts
to start the new model using definitions and preferences that are specified in a
typical ETABS .edb file that has the name Default.edb and that is stored in the
same directory as the ETABS.exe so that ETABS can locate the Default.edb
automatically. If no Default.edb file is present in that directory, ETABS displays
the Building Plan Grid System and Story Data Definition form ; use that form
to begin the process of creating the Default.edb file; then store the Default.edb
file in the appropriate subdirectory for future use with this option.
• ‘No’ button. ETABS displays the Building Plan Grid System and Story Data
Definition form.

For this particular example, click on ‘No’ button as we will create a new model from
the scratch without using existing .edb files. This leads to the following ‘Building Plan
Grid System and Story Data Definition’ window.

Figure 3
When this window appears, use it to review/modify grid and story dimensions and to
choose to use a template to start the model or to use only grid lines. The plan view of
the building will be modelled using grids. Thus, the grids will be used to define the
location of beams, columns and other structural members horizontally.
§ ‘Grid Dimensions (Plan)’ options. Choose an option for defining the
grid spacing for the model.

7 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

o ‘Uniform Grid Spacing’ option. Specify the number of grid lines


in the X and Y directions and a uniform spacing for those lines.
Note that the uniform spacing in the X direction can be different
from the uniform spacing in the Y direction. This option defines a
grid system for the global coordinate system only.
o ‘Custom Grid Spacing’ option. This option allows non-uniformly
spaced grid lines to be defined in the X and Y directions for the
global coordinate system. Choose this option and then click the
‘Edit Grid’ button to access the ‘Define Grid Data’ form. Use
that form to label grid lines, specify spacing, appearance and the
like. Use this form to label grid lines to match labeling on plans.
Regardless of which option is used to initially define grid lines, the grid
lines can be edited and additional coordinate/grid systems can be defined
in the model using the ‘Edit’ menu > ‘Edit Grid Data’ command.
§ ‘Story Dimensions’ options. Choose an option for defining the
number and height of the stories in the model.
o ‘Simple Story Data’ option. When this option is selected, use the
defaults or specify values for the Number of Stories, Typical Story
Height, and Bottom Story Height in the edit boxes. The value
specified for the Typical Story Height will be used for all stories in
the model, except the bottom story. ETABS will assign default
names to each story. This data can be modified later using the Edit
menu > Edit Story Data command.
o ‘Custom Story Data’ option. Use this option to manually define
story names, story levels of non-uniform height, and story
similarity. Click the Edit Story Data button to access the Story Data
form. Click directly in the edit boxes to change any of the items.
§ ‘Units’ drop-down list. Use this drop-down list to select the units for data
entry on this form. The selection made here does not affect the base units
selected using the drop-down list in the right corner of the Status bar.
§ Steel Deck, Staggered Truss, Flat Slab, Flat Slab with Perimeter
Beams, Waffle Slab, Two Way or Ribbed Slab and Grid Only buttons.
Use these buttons to add objects to a model, or to start the model using
only a grid system. In most cases, using templates to start a model is the
simplest, most convenient and quickest method, although it is not
necessary because the other commands in the program can be used to
draw, edit, define and assign the necessary components to create a model.
Using templates is recommended if the program is new to you.
As can be noted from the architectural plan, the center-to-center distance between the
columns is not uniform. This forces us to create non-uniform grids. As a result, for this

8 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

example, since there are no uniform grid spacing nor uniform story height, the ‘Custom
Grid Spacing’ and ‘Custom Story Data’ options will be used.
To create non-uniform grids:
Access the ‘Define Grid Data’ window using either of the following methods:

Method 1
From the window on figure 3, click on ‘Custom Grid Spacing’ > ‘Edit
Grid…’

Method 2
Click the ‘Edit’ menu > ‘Edit Grid Data’ >’Edit Grid’ command to
access the Coordinate Systems form. Then click the ‘Add New System’
button to display the ‘Coordinate System Definition’ window; click the
‘Edit Grid’ button. This method is particularly helpful if a grid system
with cylindrical coordinate system is desired.

Figure 4
In this window, the drop-down menu in the ‘Units’ box will be set to ‘KN-m’ as
desired. However, a suitable radio button, ‘Ordinates’ or ‘Spacing’, from the ‘Display
Grids as’ box should be selected. Choose ‘Ordinates’ if you want to enter the locations
of the points defining the grid line using coordinates in the current units relative to the
origin. Choose ‘Spacing’ if you want to enter the locations of the points defining the
9 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

grid line using spacing between the grid lines in the current units. In this example we
will use the ‘Spacing’ option. As can be noted from the typical floor plan (first-tenth
floor plan) of the building in this example, taking the bottom left corner as an origin,
the spacings between the grid lines in x-direction are 2,5,4,7,5.5,3.5 and in y-direction
are 3,6.5,5.5,6,3. Thus, these values will be entered in the ‘Spacing’ columns of ‘X Grid
Data’ and ‘Y Grid Data’ boxes of the ‘Define Grid Data’ window shown in Fig. 4.
For both cases, the last spacing value should be set to zero. The grid line can be a
primary or secondary line. Click in the cell corresponding to ‘Line Type’ column to
choose the appropriate option. Primary grid lines are intended to represent the main
architectural grid lines of the building. Primary grid lines must have a grid line ID, which
is displayed in a bubble on screen. Secondary grid lines are intended as temporary
reference lines for modeling and do not have a bubble assigned to them for the grid
ID. Use the ‘View menu’ > ‘Set Display’ Options command to collectively hide the
secondary grid lines from view.

Clicking ‘OK’ in the window shown in Fig 4 returns to the window shown in Fig. 3.
After this the data regarding the story heights will be entered. For the building in this
particular example, the story heights are non-uniform. Thus, the story dimensions will
be entered through the ‘Custom Story Data’ option. For a normal G+10 building,
there will be 12 stories including the foundation column. Therefore, enter this number
in front of ‘Number of Stories’ after clicking on ‘Simple Story Data’ in the window
shown in Fig. 3.

To create non-uniform stories:


From the window on figure 3, click on ‘Custom Story Data’ > ‘Edit Story
Data…’ and the following ‘Story Data’ window will appear.

10 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 5
In the above window, the values shown in ‘Height’ column are the interstory height of
the story level. It is the distance from the considered story level to the story level below.
Therefore, in this column, change the value to 2 for ‘STORY1’ which is the foundation
column and to 4 for ‘STORY2’ which is the ground floor. The rest stories will have a
height of 3m. The ‘Master Story’ column is used to assign whether a given story is used
as a template for other stories or not. This helps to replicate the drawing, assignment
and selection of the given master story to other similar stories. In this example, we will
have two master stories: the first floor (STORY2) and the sixth floor (STORY7)
because the structural element sizes and the floor plan of the first floor through fifth
floor are similar and the same is true from sixth floor to tenth floor. The ‘STORY2’ is
master story to second through fifth floors while ‘STORY7’ is master story to seventh
through tenth floors. In the ‘Similar To’ column, select the story level to which that
particular story is similar. In this example, the roof floor (STORY12) and the ground
floor (STORY1) are similar to none. But, ‘STORY3’ through ‘STORY6’ are similar to
‘STORY2’ while ‘STORY8’ through ‘STORY11’ are similar to ‘STORY7’. The ‘Splice
Point’ and ‘Splice Height’ columns are used to specify if a splice occurs at this story
level and to specify the splice height. The splice height is the distance from the bottom
of the considered story up to the column splice location.
The ‘Reset Selected Rows’ box provides edit boxes, drop-down lists, and display
boxes along with Reset buttons for the various parameters in the spreadsheet in the
11 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

upper portion of the from. Change one or more parameters shown and click the Reset
button to change the data for all columns of that type. For example, assume that the
spreadsheet area displays rows of data for STORY 4, STORY 3, STORY 2, STORY1
and BASE. Assume that the Height for Stories 4, 3, 2, and 1 are 10, 23, 12, and 12,
respectively. If 15 is entered in the Height edit box in the Reset Selected Rows area and
the Reset button is clicked, the Height for all stories will change to 15.
Then click ‘OK’ on both windows in Fig. 5 and Fig. 3. This results in the following
window. After clicking ‘OK’, if you want to modify the story height that you entered at
a later time, click ‘Edit’ menu > ‘Edit Story Data’ > ‘Edit Story’.

Figure 6

2.2. Define Materials

Before defining the different materials which will be used for the design, it is better to
set the design code other preferences which are appropriate for the design. To do this,
click on ‘Options’ menu> ‘Preferences…’> ‘Concrete Frame Design…’ and the
following ‘Concrete Frame Design Preferences’ window will appear.

12 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 7

Set the preferences as in the above window. ‘BS8110 97’ is selected as the ‘Design
code’ because the Ethiopian Building Code Standard (EBCS-2) is much similar to this
British Standard.

After this, the materials which will be used in the design will be defined. Since the
building in this example will be design using a reinforced concrete, only this material
will be defined. But in ETABS, there is also an option to define other materials. To
define the concrete material, click on ‘Define’ menu>’Material Properties’ and the
following ‘Define Materials’ window will pop-up.

Figure 8

In this window, to define a new concrete material, highlight on ‘CONC’ and click on
‘Add New Material…’ button and the following ‘Material Property Data’ window
will appear.

13 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 9
In the above window, assign the ‘Material Name’ to any name which can be identified
at a later time. Here, we name the concrete material as ‘C30’. Based on EBCS-2, the
property data for C-30 concrete and S-400 steel are entered in the previously established
unit, KN-m. The ‘Type of Material’ is set to ‘Isotropic’ because the behavior of the
reinforced concrete is assumed to be identical in all direction which is often the case.
However, a concrete material having different properties in different directions can also
be defined through the ‘Orthotropic’ radio button. Make sure that the ‘Type of
Design’ is set to ‘Concrete’. The ‘Lightweight Concrete’ checkbox is used to set the
shear strength reduction factor for lightweight concrete materials.

2.3. Define Sections

The next step is defining the sections of the structural elements such as beams, columns,
slabs and walls which will be used in the design. From the given data in section 2 of this
tutorial, there will be four types of columns, two types of beams, a shear wall and a slab.
Thus, this sections should be defined accordingly.

Defining the columns and beams

To define columns and beams click on ‘Define’ menu > ‘Frame Sections…’ and the
following ‘Define Frame Properties’ window will pop-up.

14 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 10

The ‘Properties’ box of this form lists the names of all of the currently defined frame
section properties. ETABS automatically creates this list. Use this command to add to,
modify it, or delete sections from it as necessary using the two drop-down lists and two
buttons in the ‘Click to’ box of the form. In this example, we will use a new section
property and give it our own easily identifiable name. For instance, a name ‘CC500’ will
be used to define a circular column of 500mm diameter. Since we don’t require any of
the pre-defined frame sections created by ETABS itself, select all the frame sections
listed in the ‘Properties’ box and click on ‘Delete Property’ button.
The Import {Property} drop-down list, initially displaying ‘Import I/Wide Flange,’ is
used to import frame section properties from one of several section databases included
on the ETABS CD or elsewhere on the computer. The Add {Property} drop-down list,
initially displaying ‘Add I/Wide Flange,’ is used to add section properties that you
specify on the basis of their section dimensions. In this example, since we are not
importing any frame section, the Add {Property} drop-down list will be used.
To create a circular column of diameter 500mm with a name of ‘CC500’, click on ‘Add
Circle’ from the Add {Property} drop-down menu and the following ‘Circle Section’
window will pop-up.

15 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 11
In this window, change the ‘Section Name’ to ‘CC500’, the ‘Material’ to ‘C30’ and
the ‘Diameter (t3)’ to ‘0.5’. The option whether to select the section is a beam or
column is achieved by clicking on the ‘Reinforcement’ button where the following
‘Reinforcement data’ window appears. In this window, the ‘Design Type’ should be
‘Column’, the ‘Configuration of Reinforcement’ should be ‘Circular’, the ‘Lateral
Reinforcement’ is ‘Ties’ but can be changed to ‘Spiral’ if spiral stirrups are used and
the right values in the ‘Circular Reinforcement’ and ‘Check/Design’ boxes should
be selected. Pressing ‘OK’ button in the windows shown in Fig. 12 and Fig. 11 creates
the intended circular column. This adds a frame section with the name ‘CC500’ in the
‘Properties’ box of the window shown in the Fig. 10.

16 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 12

While the window shown in Fig. 10 is active, the rest column and beam frame sections
can be defined.

To create the circular column of diameter 400mm


Click on ‘Add Circle’ from the Add {Property} drop-down menu. Change
the ‘Section Name’ to ‘CC400’, the ‘Material’ to ‘C30’ and the
‘Diameter(t3)’ to ‘0.4’ and click on ‘Reinforcement’ in the appearing
window. In the ‘Reinforcement Data’ window, adjust the options
accordingly and click ‘OK’ both on this window and ‘Circle Section’
window. This adds a section named ‘CC400’ in the properties box of the
‘Define Frame Properties’ window.
To create the rectangular column of size 400X800mm
Click on ‘Add Rectangular’ from the Add {Property} drop-down menu.
Change the ‘Section Name’ to ‘RC400X800’, the ‘Material’ to ‘C30’ and
the ‘Depth(t3)’ to ‘0.8’, the ‘Width(t2)’ to ‘0.4’ ( t2 is a dimension normal
to the local axis 2 which is directed in global positive x-axis direction for
vertical elements and t3 is a dimension normal to the local axis 3 which is
directed in global positive y-axis direction for vertical elements) and click
on ‘Reinforcement’ in the appearing window. In the ‘Reinforcement
Data’ window, adjust the options accordingly and click ‘OK’ both on this
window and ‘Rectangular Section’ window. This adds a section named

17 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

‘RC400X800’ in the properties box of the ‘Define Frame Properties’


window.

To create the rectangular column of size 300X600mm


Click on ‘Add Rectangular’ from the Add {Property} drop-down menu.
Change the ‘Section Name’ to ‘RC300X600’, the ‘Material’ to ‘C30’ and
the ‘Depth(t3)’ to ‘0.6’, the ‘Width(t2)’ to ‘0.3’ and click on
‘Reinforcement’ in the appearing window. In the ‘Reinforcement Data’
window, adjust the options accordingly and click ‘OK’ both on this
window and ‘Rectangular Section’ window. This adds a section named
‘RC300X600’ in the properties box of the ‘Define Frame Properties’
window.
To create the rectangular beam of size 300X500mm
Click on ‘Add Rectangular’ from the Add {Property} drop-down menu.
Change the ‘Section Name’ to ‘RB300X500’, the ‘Material’ to ‘C30’ and
the ‘Depth(t3)’ to ‘0.5’, the ‘Width(t2)’ to ‘0.3’ ( t2 is a dimension normal
to the local axis 2 which is directed in global positive z-axis direction for
vertical elements and t3 is a dimension normal t2) and click on
‘Reinforcement’ in the appearing window. In the ‘Reinforcement Data’
window, change the ‘Design Type’ to ‘Beam’ and adjust the options
accordingly and click ‘OK’ both on this window and ‘Rectangular
Section’ window. This adds a section named ‘RB300X500’ in the
properties box of the ‘Define Frame Properties’ window. The
‘Reinforcement Override for Ductile Beams’ box in the
‘Reinforcement Data’ window is used to specify areas of longitudinal
reinforcing steel that occur at the top and bottom of the left and right
ends of the beam.
To create the rectangular beam of size 250X400mm
Click on ‘Add Rectangular’ from the Add {Property} drop-down menu.
Change the ‘Section Name’ to ‘RB250X400’, the ‘Material’ to ‘C30’ and
the ‘Depth(t3)’ to ‘0.4’, the ‘Width(t2)’ to ‘0.25’ and click on
‘Reinforcement’ in the appearing window. In the ‘Reinforcement Data’
window, change the ‘Design Type’ to ‘Beam’ and adjust the options
accordingly and click ‘OK’ both on this window and ‘Rectangular
Section’ window. This adds a section named ‘RB250X400’ in the
properties box of the ‘Define Frame Properties’ window.

Then click ‘OK’ on the window shown in Fig. 10, the desired column and beam sections
will be created.

18 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Defining the Slabs and walls

To define slabs click on ‘Define’ menu> ‘Wall/Slab/Deck Sections…’ and the


following ‘Define Wall/Slab/Deck Sections’ window will appear.

Figure 13
The ‘Sections’ box of the window shown in Fig. 13 lists some pre-defined sections
suggested by ETABS. If you want to use these sections by modifying them, you can
highlight any of them and click on ‘Modify/Show Section…’ button. For this
example, we will create a new slab and wall sections with easily identifiable name and
we don’t require any of the pre-defined sections. Therefore, highlight all of them and
click on ‘Delete Section’ button.

To define a slab section of 230mm thickness, click on ‘Add New Slab’ from the drop-
down menu in the ‘Click to:’ box resulting in the appearance of the following
‘Wall/Slab Section’ window.

19 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 14

In the above window, change the ‘Section Name’ to ‘S230’, the ‘Material’ to ‘C30’
and the ‘Thickness’ for both ‘Membrane’ and ‘Bending’ to ‘0.23’. A wall or slab
section can have shell, membrane or plate-type behavior. Shell-type behavior means
that both in-plane membrane stiffness and out-of-plane plate bending stiffness are
provided for the section. Membrane-type behavior means that only in-plane membrane
stiffness is provided for the section. Plate-type behavior means that only out-of-plane
plate bending stiffness is provided for the section. Since the both in-plane membrane
stiffness and out-of-plane plate bending stiffness will be considered, set the radio button
in ‘Type’ box to ‘Shell’. When the ‘Use Special One-Way Load Distribution’
checkbox is checked, the load applied to area objects with this section property is to be
distributed as a one-way slab spanning in the local 1 direction of the area object. Click
the ‘Set Modifiers’ button to access the ‘Analysis Stiffness Modification Factors’
window. Use this window to specify the stiffnesses, mass, and weight for the property
definition. Since we don’t require special one-way load distribution just click ‘OK’
button and the slab will be created.

To define a shear wall of 300mm thickness click on ‘Add New Wall’ from the drop-
down menu in the ‘Click to:’ box of the window shown in Fig. 13. In the resulting
window, change the ‘Section Name’ to ‘SW300’, the ‘Material’ to ‘C30’ and the
‘Thickness’ for both ‘Membrane’ and ‘Bending’ to ‘0.3’. Since the both in-plane
membrane stiffness and out-of-plane plate bending stiffness will be considered, set the

20 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

radio button in ‘Type’ box to ‘Shell’. Then click ‘OK’ button and the shear wall will be
created. Again press the ‘OK’ button on the window shown in Fig. 13. In the
meanwhile, it may be important to save the file on the computer.

2.4. Add Geometry to the Model

Once the structural sections are defined, the next step is to add those sections to the
model. This is done as follows:
Adding Beams to the Model
The plan view is particularly useful to add beams. Thus, make sure that the plan
view is active. If the plan view is not active, you can click on ‘View’ menu> ‘Set
Plan View’ command. You may also frequently use the ‘Move Up in List’ and
‘Move Down in List’ buttons to switch between different floors. These
buttons are available in the list of buttons on the toolbar just below the menu bar.
Beams can be added to the model in two different ways. The first option is
accessed by clicking on ‘Draw’ menu> ‘Draw Line Objects’ > ‘Draw Lines
(Plan,Elev,3D)’ or by clicking the equivalent button from the left hand side
toolbar . This option creates a beam element by left clicking at the beginning
point, dragging the mouse to the end point and making another left click. To end
drawing by this option you can make double left click at the ending point or press
the ‘Enter’ key. The second option is accessed by clicking on ‘Draw’ menu>
‘Draw Line Objects’ > ‘Create Lines in Region or at Clicks (Plan,Elev,3D)’
or by clicking the equivalent button from the left hand side toolbar . This
option creates a beam element by left clicking on any grid line. By this second
option, you can also draw multiple beam elements at once by holding down the
left mouse button and by dragging the cursor on the gridlines where you want to
draw the beam elements. The second option is quicker and we will use it to create
the beam elements in this example.
Ground Floor Beams:
The ground floor is similar to none of the other stories. Thus, make sure that the
‘One Story’ is selected in the Similar To drop-down list on the right hand side of
the status bar. By using the ‘Move Up in List’ and ‘Move Down in List’ buttons,
make sure that the ground floor is active on the plan view. When the ground floor
is active, both the title of the window and the on the left hand side of the status
bar display ‘Plan View- STORY1 – Elevation 2’. Then click on . This results
in the appearance of the following ‘Properties of Object’ window.

21 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 15
In this window, the ‘Type of Line’ should be set to ‘Frame’, the ‘Property’ to
‘RB300X500’ and the ‘Moment Relseases’ to ‘Continuous’ before drawing the
beam which is 300X500mm in dimensions. Then click on all grid lines between
axis B and axis G on the plan view. As can be seen from the architectural plan, the
ground floor doesn’t have any beams between axis A and axis B.

First through Fifth Floor Beams:


The floors from first to fifth floors are similar. As a result, beams on other stories
can be replicated simultaneously by drawing beam elements on the master story
by setting the Similar To drop-down list on the status bar to ‘Similar Stories’.
While defining the stories, the first floor was made the master story. While the
above ‘Properties of Object’ window is active, by using the ‘Move Up in List’ and
‘Move Down in List’ buttons, make sure that the first floor is active on the plan
view. When the first floor is active, both the title of the window and the on the
left hand side of the status bar display ‘Plan View- STORY2 – Elevation 6’. Then
click on all grid lines between axis A and axis G on the plan view. This draws all
beams from first floor to fifth floor having dimensions 300X500mm.
Sixth through Tenth Floor Beams:
The floors from sixth to tenth floors are similar. Thus, set the Similar To drop-
down list on the status bar to ‘Similar Stories’. While defining the stories, the
sixth floor was made the master story. In the ‘Properties of Object’ window,
change the ‘Property’ to ‘RB250X400’. By using the ‘Move Up in List’ and ‘Move
Down in List’ buttons, make sure that the sixth floor is active on the plan view.
When the sixth floor is active, both the title of the window and the on the left
hand side of the status bar display ‘Plan View- STORY7 – Elevation 21’. Then
click on all grid lines between axis A and axis G on the plan view. This draws all
beams from sixth floor to tenth floor having dimensions 250X400mm.
Roof Floor Beams:
The roof floor is similar to none of the other stories. Thus, make sure that the
‘One Story’ is selected in the Similar To drop-down list on the right hand side of
the status bar. By using the ‘Move Up in List’ and ‘Move Down in List’ buttons,
make sure that the roof floor is active on the plan view. When the roof floor is
active, both the title of the window and the on the left hand side of the status bar
display ‘Plan View- STORY12 – Elevation 36’. Making sure that that the
‘Property’ is set to ‘RB250X400’ in the ‘Properties of Object’ window, click on

22 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

all grid lines between axis A and axis G on the plan view. This draws all beams for
the roof floor having dimensions 250X400mm.
Adding Columns to the Model
The plan view is particularly useful to add columns. Columns can be added to the
model by clicking on ‘Draw’ menu> ‘Draw Line Objects’ > ‘Create Columns
in Region or at Clicks (Plan,Elev,3D)’ or by clicking the equivalent button from
the left hand side toolbar . This creates a column element by left clicking on
any point on the plan view. Multiple column elements can also be drawn at once
by holding down the left mouse button and by dragging the cursor on the gridline
intersections where you want to draw the beam elements. When is clicked, the
following window will appear.

Figure 16
Different cross-sections of the column can be added by changing the ‘Property’
to appropriate cross-section. There are no columns along axis A. The circular
columns of different dimensions will be added along axis B, while all other axes
will have rectangular columns. There is no column at the intersection of axis D
and axis 2. When columns are drawn using the plan view in ETABS, a given floor
plan will be used to draw columns below that floor. For instance, the ground floor
will be used to draw the foundation columns and the roof floor will be used to
draw the tenth floor columns.
Foundation Columns:
The ground floor is similar to none of the other stories. Thus, make sure that the
‘One Story’ is selected in the Similar To drop-down list on the right hand side of
the status bar. By using the ‘Move Up in List’ and ‘Move Down in List’ buttons,
make sure that the ground floor is active on the plan view. When the ground floor
is active, both the title of the window and the on the left hand side of the status
bar display ‘Plan View- STORY1 – Elevation 2’. Then click on . This results
in the appearance of the ‘Properties of Object’ window shown in Fig. 16. Make
sure that, in this window, the ‘Property’ is set to ‘CC500’ when you click at grid
line intersections along axis B and to ‘RC400X800’ when you click at grid line
intersections at other applicable locations where rectangular columns exist.
Ground through Fourth Floor Columns:
The floors from first to fifth floors are similar. As a result, columns on other stories
can be replicated simultaneously by drawing column elements on the master story
by setting the Similar To drop-down list on the status bar to ‘Similar Stories’.
23 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

While defining the stories, the first floor was made the master story. While the
above ‘Properties of Object’ window is active, by using the ‘Move Up in List’ and
‘Move Down in List’ buttons, make sure that the first floor is active on the plan
view. When the first floor is active, both the title of the window and the on the
left hand side of the status bar display ‘Plan View- STORY2 – Elevation 6’. Make
sure that, in the window shown in Fig. 16, the ‘Property’ is set to ‘CC500’ when
you click at grid line intersections along axis B and to ‘RC400X800’ when you click
at grid line intersections at other applicable locations where rectangular columns
exist.
Fifth through Ninth Floor Columns:
The floors from sixth to tenth floors are similar. Thus, set the Similar To drop-
down list on the status bar to ‘Similar Stories’. While defining the stories, the
sixth floor was made the master story. By using the ‘Move Up in List’ and ‘Move
Down in List’ buttons, make sure that the sixth floor is active on the plan view.
When the sixth floor is active, both the title of the window and the on the left
hand side of the status bar display ‘Plan View- STORY7 – Elevation 21’. Make
sure that, in the window shown in Fig. 16, the ‘Property’ is set to ‘CC400’ when
you click at grid line intersections along axis B and to ‘RC300X600’ when you click
at grid line intersections at other applicable locations where rectangular columns
exist.
Tenth Floor Columns:
The roof floor is similar to none of the other stories. Thus, make sure that the
‘One Story’ is selected in the Similar To drop-down list on the right hand side of
the status bar. By using the ‘Move Up in List’ and ‘Move Down in List’ buttons,
make sure that the roof floor is active on the plan view. When the roof floor is
active, both the title of the window and the on the left hand side of the status bar
display ‘Plan View- STORY12 – Elevation 36’. Make sure that, in the window
shown in Fig. 16, the ‘Property’ is set to ‘CC400’ when you click at grid line
intersections along axis B and to ‘RC300X600’ when you click at grid line
intersections at other applicable locations where rectangular columns exist.
Adding Slabs to the Model
The plan view is particularly useful to add columns. Slabs can be added to the
model by three options. The first option is achieved by clicking on ‘Draw’
menu> ‘Draw Area Objects’ > ‘Draw Areas (Plan,Elev,3D)’ or by clicking
the equivalent button from the left hand side toolbar. To draw a slab
element by this option left click once at the first corner point of the area, drag
the mouse to the next corner point and left click, and so on to define each corner
point of the area object. Note that the mouse is dragged, a dashed line is visible
indicating the current extent of the area object. At the last corner point of the
area object, double left click to finish the object or single left click and press the
Enter key on the keyboard. An area object drawn using this command must have
24 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

at least three corner points. Typically area objects are limited to no more than
four corner points; however, there is no limit on the maximum number of corner
points allowed for horizontal area objects.
The second option is achieved by clicking on ‘Draw’ menu> ‘Draw Area
Objects’ > ‘Draw Rectangular Areas (Plan,Elev)’ or by clicking the
equivalent button from the left hand side toolbar. To draw a slab element by
this option Left click once to define the position of one corner point of the area.
Drag the mouse and left click again to define the diagonally opposite corner
point. Note that as the mouse is dragged, a dashed line is visible indicating the
current extent of the area object.When using this command in an elevation view,
if an area object is drawn such that it crosses story levels, ETABS immediately
breaks the object at the story levels.
The third option is achieved by clicking on ‘Draw’ menu> ‘Draw Area
Objects’ > ‘Create Areas at Click (Plan,Elev)’ or by clicking the equivalent
button from the left hand side toolbar. To draw a slab element by this option
Click in any grid line space and an area object is drawn in that grid line space.
Depress and hold down the left mouse button. While keeping the left button
depressed, drag the mouse to "rubber band" a window around one or more grid
line spaces. Then release the left mouse button. Area objects are automatically
placed in each grid line space included in the "rubber band" window.
The third option is the quickest and we will use it to add slabs to the model in
this example. The slabs for all floors are the same. Of course, the slab sections
will not be added to the ground floor. At this stage, slab sections will be added
to all the panels in a given floor and the opennings for staircases and elevators
will be created later. The slabs from the first to roof floor can be added in two
ways. The first way to add slabs for all stories by setting the Similar To drop-down
menu to ‘All Stories’ and draw the slabs for all panels. Then, delete all the slabs
on the ground floor by setting the Similar To drop-down menu to ‘One Story’.
The second way, which will be used in this example, is to add all the slabs for
any floor other than the ground floor and replicate them for the rest stories by
using the ‘Replicate’ command in the ‘Edit’ menu.
Thus, click on button and the following ‘Properties of Object’ window will
appear. In this window, make sure that the ‘Property’ is set to ‘S230’. Note that
is the slab section for all floors which is defined earlier.

Figure 17
Then, change the story level to any story level other than the ground floor, set
the Similar To drop-down menu to ‘One Story’ and click inside all panels on that
25 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

particular floor. This adds slab sections for all panels in that given floor. Then
close the ‘Properties of Object’ window shown in Fig. 17. After this click on
‘Draw’ menu > ‘Select Object’ or just click from the left hand side toolbar.
Then click inside all the panels to select the slabs for replication. The selection
of the slabs is accompanies by drawing an area with broken lines in the given
panels. When you select all the panels, the left hand side of the status bar shows
’30 Areas, 120 Edges selected’. To replicate the slabs, click on ‘Edit’ menu>
‘Replicate’. This results in the following ‘Replicate’ window.

Figure 18
In the ‘Story’ tab of the window shown in Fig. 18, select all the stories for which
the slabs will be added (STORY2 to STORY12) by clicking on them while
holding the ‘Shift’ key. This adds slabs to all floors except the ground floor.

Adding Slab Openings to the Model

After creating the slabs, the openings on the slabs for staircases and elevators
will be added. These openings continue from first floor (STORY2) to tenth floor
(STORY11). Thus the openings will be created for one of these floors and
replicated for other floors.
There are two staircase openings (2650X4150mm) and three continuous elevator
openings (total dimension of 2200mmX4400mm center-to-center). Let us name
the staircase bounded by axes 4-5-C-D as staircase1. The other staircase as
staircase2.
To create openings in the middle of the slab, points marking corner points of the
openings should be defined first. This points are defined by following the ‘Draw’
menu > ‘Draw Point Objects’ command. For a better visualization of the
openings while being created, you can fill the slabs by following ‘View’ menu>
‘Set Building View Options…’ command and checking the ‘Object Fill’
option in the ‘Special Effects’ box.

26 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Staircase corner points

Three corner points will be created for each staircase, the other corner point
being the center of the nearest columns. The relative positions of these corner
points from the nearest columns for both staircase1 and staircase2 are the same,
as can be viewed from the plan view. Thus, corresponding points can be created
simultaneously for both staircases. To create these points, click on ‘Draw’ menu
> ‘Draw Point Objects’ command and the following ‘Properties of Object’
window will appear. Make sure that the Similar To drop-down menu in the status
bar is set to ‘One Story’.

Figure 19

In this window, the value of ‘Plan Offset X’ should be the relative distance
between the point where you want to create and the point where you will click in
x-direction. The value of ‘Plan Offset Y’ should be the relative distance between
the point where you want to create and the point where you will click in y-direction.
These values can also be negative. For staircase1, the click point will be the center
of the column at the intersection of the axes 5 and C; whereas for staircase2, it will
be at the intersection of axes 3 and C. To create the first point for both staircases,
set the value of ‘Plan Offset X’ to 2.65 and ‘Plan Offset Y’ to 0 in the window
shown in Fig 19 and click at the click points for both staircases. To create the
second point for both staircases, set the value of ‘Plan Offset X’ to 2.65 and ‘Plan
Offset Y’ to -4.15 in the window shown in Fig 19 and click at the click points for
both staircases. To create the third point for both staircases, set the value of ‘Plan
Offset X’ to 0 and ‘Plan Offset Y’ to -4.15 in the window shown in Fig 19 and
click at the click points for both staircases. Now, you see that three points defining
the corner points of the staircases are created.

Elevator corner points

Three corner points will be created as the intersection of axes 2 and D makes the
other corner point. The click point will be the intersection of the axes 2 and D. To
create the first point for both for the elevator opening, set the value of ‘Plan
Offset X’ to 2.2 and ‘Plan Offset Y’ to 0 in the window shown in Fig 19 and click
at the click point. To create the second point for the elevator opening, set the value
of ‘Plan Offset X’ to 2.2 and ‘Plan Offset Y’ to 4.4 in the window shown in Fig
19 and click at the click point. To create the third point for both staircases, set the
27 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

value of ‘Plan Offset X’ to 0 and ‘Plan Offset Y’ to 4.4 in the window shown in
Fig 19 and click at the click point. Now, you see that three points defining the
corner points of the elevator openig are created.

To create the openings, click on ‘Draw’ menu> ‘Draw Area Objects’> ‘Draw
Rectangular Areas (Plan, Elev)’ command. This results in the appearance of the
following ‘Properties of Object’ window.

Figure 20
In the above window, set the ‘Property’ to ‘OPENING’ and click on one of
corner points and while holding the left click drag to the opposite corner and
release the click for all the openings. This creates openings for both staircases and
the elevator on the given floor. To replicate these openings for the other floors,
click on all openings and click on ‘Edit’ menu > ‘Replicate’ command. In the
‘Story’ tab of the resulting window, select all the stories (STORY2 to STORY11)
where the openings will be replicated by holding down the ‘Shift’ key and press
‘OK’. Now, the openings will be replicated for all the applicable floors.
Adding Intermediate Beams to the Model

Intermediate beams are necessary at the intersection of the two flights of the
stair. These stair flights exist for all stories except the first (foundation column)
and the last (tenth floor). The intermediate beams extend between axes C and D
along axis 5 for staircase1 and along axis 3 for staircase2. The story heights for
the floors where there are stair flights is 3m except for the first floor (STORY2),
which is 4m. The intermediate beams will be added at the middle of the story.
Since the locations of the intermediate beams from STORY3 to STORY11 are
the same, the beams will be drawn for one of these floors and replicated for the
other floors. The intermediate beam for STORY2 will be drawn separately. For
simplicity, change the window views to plan and elevation views.

To snap to mid-points, change the snap option by clicking on ‘Draw’


menu>’Snap To’> ‘Line Ends and Midpoints’. Then click on ‘Draw’
menu>’Draw Line Objects’>’Draw Lines (Plan,Elev,3D). In the resulting
‘Properties of Object’ window, change the ‘Property’ to ‘RB250X400’. Then
on the elevation view to ‘Elevation view-5’. Make sure that on the plan view,
axis 5 is highlighted. Then, draw a beam element between axes C and D by
clicking at the mid points of the parallel columns bounded by axes C and D
between STORY10 and STORY11. Make a right click to finish the drawing. By

28 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

a similar process draw an intermediate beam between STORY1 and STORY2.


Then switch the elevation view to ‘Elevation view-3’ and again draw the two
beams for the same stories as above. Then, from ‘Elevation view-5’ and
‘Elevation view-3’ select the beams between STORY10 and STORY11 after
clicking on the ‘Select Object’ arrow. Then, click on ‘Edit’ menu > ‘Replicate’
command. In the ‘Story’ tab of the resulting window, select all the stories where
the intermediate beams will be replicated (STORY3 to STORY11) by holding
down the ‘Shift’ key and press ‘OK’. This creates the all necessary intermediate
beams for both staircases.

Adding Stairs to the Model

Since stairs act as an integral component of the building frame, they should be
added to the model. The stairs which will be added to the model consists of two
parts: the landing and the flights. The landings are at the same level as the
intermediate beams whereas the flights extend from the landing to the
consequent floors. Thus, first we draw the landings and the drawing of the flights
will follow.

Landings
Before drawing the landings, it may be advantageous to add grid lines at the levels
of the intermediate beams. To add this grid lines, click on ‘Edit’ menu>’Edit
Reference Planes…’ and the following ‘Edit Reference Planes’ window will
appear.

29 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 21
In this window, in the text box below ‘Z-Ord’, enter the Z-coordinate where you
want to insert the reference plane and click on ‘Add’. For instance, the level of the
intermediate beam for the ground floor has z-coordinate of 4 and that of first floor
has z-coordinate of 7.5 and so on. Repeat this process until all the grid lines are
added for all the intermediate beams. When you finish, click ‘OK’.

For a better view while drawing the landing, the elevation and the plan view should
be active. Now, switch to the reference plane between STORY10 and STORY11.
If the intended reference plane is highlighted, the elevation on the plan view should
be 31.5. You will see two intermediate beams on the plan view, one along axis 3
and the other along axis 5. Points marking the corner points of the landing will be
drawn on these beams. Before drawing the points, make sure that the Similar To
drop-down menu in the status bar is set to ‘One Story’.

The first set of points will be at a distance of 2.65m from axis C along axes 3 and
5. To add these points, click on ‘Draw’ menu>’Draw Point Objects’. In the
resulting ‘Properties of Object’ window, set the value of ‘Plan Offset X’ value
to 2.65 and ‘Plan Offset Y’ value to 0. Then, click at the intersections of the axis
C and the two axes (axes 3 and 5). This creates two points on each intermediate
beams. Then set the value of ‘Plan Offset X’ value to 2.65 and ‘Plan Offset Y’
value to -1.15(the width of the landing is 1.15m). Then, click at the intersections
of the axis C and the two axes (axes 3 and 5). Then, set the value of ‘Plan Offset
X’ value to 0 and ‘Plan Offset Y’ value to -1.15. Then, click at the intersections of
the axis C and the two axes (axes 3 and 5). This creates the corner points of the
landings.

To draw the landings, click ‘Draw’ menu>’Draw Area Objects’>’Draw


Rectangular Areas (Plan, Elev)’. In the resulting ‘Properties of Object’
window, set the ‘Property’ to ‘S230’ and click on one of the created points, holding
down the left click drag to the opposite point and release the click. Do this for
both staircases and you will create the landings for STORY11. Since the stories
from STORY2 to STORY11 have the same story height, the landings drawn for
STORY11 will be replicated for these stories. To do this, select both the landings
after clicking the ‘Select Object’ arrow. If both landings are created properly, the
status bar shows ‘2 Areas, 8 Edges selected’. You may need to make multiple
clicks on the landings to get this message. Then, click on ‘Edit’ menu>’Replicate’.
In the ‘Story’ tab of the resulting window, select STORY3 up to STORY11 by
holding down the ‘Shift’ key and press ‘OK’. This draws the landings between
STORY3 and STORY11. Repeat the above process to draw the landings for
STORY1.
30 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Flights
From the landings, the two flights connecting the landings with successive floors
will be drawn. To draw these flights, line elements having equal width with each
flight should be drawn first on the edges of the landings.

Making sure that the Similar To drop-down menu in the status bar is set to ‘One
Story’, switch to the reference plane between STORY10 and STORY11 on the
plan view. You will see two landings with four corner points. Now, two extra
points on each landing marking the end points of the flights on that landing will
be drawn. For the first landing, the relative position of the first point from the
intersection of the axis C and axes 3 is 1.15m in x-direction and -1.15m in y-
direction. The relative position of the second point from the intersection point is
1.5m in x-direction and -1.15m in y-direction. For the second landing, the relative
position of the two points are the same as above from the intersection of axis C
and axis 5. Thus, the two points will be simultaneously created for both landings.
To create these points, click on ‘Draw’ menu>’Draw Point Objects’. In the
resulting ‘Property of Object’ window, set the ‘Plan Offset X’ to 1.15 and ‘Plan
Offset Y’ to -1.15 and click at the intersection of axis C with axes 3 and 5. While
the ‘Property of Object’ window is active, set the ‘Plan Offset X’ to 1.5 and ‘Plan
Offset Y’ to -1.15 and click at the intersection of axis C with axes 3 and 5. This
creates four points on the two landings.

After this, two line elements will be drawn on each landing on the edge of the
landing where there are now four points. One line elements will be drawn on each
landing between the first and second points and another line element between the
third and the fourth points for each landing. To draw these lines, click on ‘Draw’
menu>’Draw Line Objects’>’Draw Lines (Plan, Elev)’. In the resulting
‘Properties of Object’ window, set the ‘Property’ to ‘NONE’. Then, draw the
line objects by left clicking at the starting point and ending points and right clicking
to finish the line object drawing. Do this for both flights. This draws two lines
from where the two flights start from the landing one in downward and the other
in upward direction.

After clicking the ‘Select Object’ arrow, select the left side beam objects which
were just created from both landings. Then click on ‘Edit’ menu>’Extrude Lines
to Areas…’ and the following ‘Extrude Lines to Areas’ window will appear.

31 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 22

In the ‘Linear’ tab of this window, Specify the increment distance along the X-
axis (dx), the increment distance along the Y-axis (dy), the increment distance
along the Z-axis (dz), and the number of times the object is to be extruded. The
object is then extruded the specified number of times, each time incrementing the
global X ,Y and Z coordinates by the specified dx, dy and dz. The selected lines
will be extruded down wards to the next floor. Thus, the value of ‘dz’ is ‘-1.5’ (half
the story height). The length of the flights from the architectural plan is 3m in
negative y-direction. Thus, the value of ‘dy’ is ‘-3’. Since there is no extrusion in
x-direction, the value of ‘dx’ is ‘0’. For each landing, only one landing is created.
Thus, the value of ‘Number’ should be set to ‘1’. Then press ‘OK’. This creates
the flights connecting each landing to the floor down for the given story.

Then select the right hand side line object from both landings and click on ‘Edit’
menu>’Extrude Lines to Areas…’. In the ‘Linear’ tab of the resulting window,
set the value of ‘dz’ to ‘1.5’ (half the story height in upward direction), the value
of ‘dy’ to ‘-3’, the value of ‘dx’ to ‘0’ and the value of ‘Number’ to ‘1’. Then press
‘OK’. This creates the flights connecting each landing to the floor up for the given
story.

With a similar procedure as above, draw the flights for the ground floor.

After this, the flights will be assigned with slab property and replicated from
STORY3 to STORY11. To select the flights, change the window which is not the
plan view to a suitable 3D view. To do this, highlight the window and click on
‘View’ menu>’Set 3D View…’ and the following ‘Set 3D View’ window will
appear.

32 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 23

In this window, set the ‘Plan’ to ‘270’, the ‘Elevation’ to ‘0’ and the ‘Aperture’ to
‘0’ and click ‘OK’. Then you will see a 3D view on XZ plane. On this widow, you
will also see the flights connecting STORY10 and STORY11. With great care,
select those flights and click on ‘Assign’ menu>’Shell/Area’>’Wall/Slab/Deck
Sections…’ and the ‘Assign Wall/Slab/Deck Sections’ window will appear.
Then, highlight ‘S230’ and click ‘OK’. This assigns a slab property to the flights.
To replicate the flights for the other floors. Again select both flights and click on
‘Edit’ menu>’Replicate’. In the ‘Story’ tab of the resulting window, select
STORY3 to STORY11 and press ‘OK’. This replicates the flights for both landings
from the STORY3 to STORY11.

Adding Shear walls to the Model

The other structural component of the building which is not yet added to the
model is shear wall. Before adding the shear walls to the model, points defining
the end points of the shear walls should be added to the model. Since the shear
walls extend for all stories, set the Similar To drop-down menu in the status bar
to ‘All Stories’. Six additional points with the following properties will be added
to the model. The properties in the table are valid if the click point is at the
intersection of axis 2 and axis D.
Point no. Plan Offset X Plan Offset Y
1 2.2 0.35
2 2.2 1.85
3 2.2 2.2
33 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

4 2.2 2.55
5 2.2 4.05
6 0 2.2

To add this points, click on ‘Draw’ menu>’Draw Point Objects’. In the resulting
‘Properties of Object’ window, set the values of ‘Plan Offset X’ and ‘Plan Offset
Y’ values as depicted in the above table and click at the click point.

To draw the shear walls, make sure that one of the windows is on plan view and
click on ‘Draw’ menu>’Draw Area Objects…’>’Draw Walls (Plan)’ or simply
click on the equivalent button from the left hand side toolbar and the
following ‘Properties of Object’ window will appear.

Figure 24

In this window, set the ‘Type of Area’ to ‘Pier’. Because the main reinforcement
in the shear walls is the vertical reinforcement. Had the main reinforcement in the
shear walls been the horizontal reinforcement, we would have set the ‘Type of
Area’ to ‘Spandrel’. The ‘Property’ should be set to ‘SW300’. The ‘Plan Offset
Normal’ is used to locate the line a certain distance from where it is drawn; all
points on the line are shifted by the offset amount to the left (looking along a line
between the start and end points) if the value is positive, and to the right if
negative. Since we will not use any offset distance, its value should be 0 and leave
the other options as they are.

2.5. Meshing and Assigning Diaphragm

Meshing
Since ETABS uses a finite element approach for analysis of structures, area objects such
as slabs and shear walls should be meshed. This is because the meshing inside the area
objects will be used to calculate the desired quantities such as deformation, shear force
and bending moment at a given point. The finer the mesh, the more reliable the result

34 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

will be. But finer meshes require more computation time and thus mesh sizes should
be optimum. It is recommended to mesh area objects at least every 0.5m in ETABS.

Meshing the shear walls


To mesh the shear wall, first select all the shear walls from every floor by clicking
‘Select’ menu>’by Wall/Slab/Deck Sections…’. In the ‘Select’ box of the resulting
‘Select Sections’ window, select ‘SW300’ and press ‘OK’. This selects all sections
which were assigned with ‘SW300’ section property. These sections are of course the
shear walls.
Then click on ‘Edit’ menu>’Mesh Areas…’. This results in the following ‘Mesh
Selected Areas’ window.

Figure 25
In this window, ‘Cookie Cut at Selected Line Object (Horiz)’ radio button is used
to mesh the selected area at the selected lines. Select one or multiple lines. If the selected
line passes through more than one area, all of the areas will be meshed. Note that this
option only work in plan view. ‘Cookie Cut at Selected Point at [Specified] Degrees
(Horiz)’ is used to mesh areas at a specified point and angle. The angle will be measured
in the counterclockwise direction for the x- and y-axis. If the point lies in the
overlapping region of two areas, both of the areas will be meshed at the given angle.
‘Mesh Quads/Triangles into [Specified Number] by [Specified Number] Areas’
is used to mesh the selected area in the number of areas specified by the user. For
example, specifying a meshing of 2 by 8 means that the selected area will be meshed
into 2 areas along the x-axis and 8 areas along the y-axis. The size of the meshed areas
will be uniform along a given direction. Only quads and triangles can be meshed using
this option. ‘Mesh Quads/Triangles at’ options work for three- and four-sided area
objects; they do not work for area objects with more than four sides:
• ‘Intersections with Visible Grids’ is used to mesh each selected area at any
location where it intersects a visible grid line, regardless of the coordinate system
associated with the grid line.
• ‘Selected Point Objects on Edges’ is used to mesh the area (horizontally and
vertically) using the selected point at the edge as reference. One more points can
be selected for this type of meshing.
35 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

• ‘Interactions with Selected Line Objects’ is used to mesh selected areas with
the line intersecting the area. More than one line can be selected to mesh a desired
area.
For this example, we use the third option: ‘Mesh Quads/Triangles into [Specified
Number] by [Specified Number] Areas’. The number of mesh quads is defined by
the optimum mesh size you want to use. If we are going to use the recommended mesh
size which is 0.5m, we will have 5 mesh quads in both x-direction and y-direction. This
is because the dimension of the shear wall in x-direction is 2.2m. Dividing this
dimension by 0.5m and rounding up results in 5. In y-direction, the shear wall is
considered as two continuous walls of total length 4.4m. Half of this dimension will be
2.2m and again resulting in 5 mesh quads. The number of meshes in z-direction assumes
the same number of meshes in y-direction. The maximum story height is 4m requiring
at least 8 mesh quads in z-direction. Thus, to fulfill the requirement of optimum mesh
size in z-direction, the number of mesh quads in y-direction should be 8. Therefore, in
the window shown in Fig. 25, select the third radio button and enter 5 by 8 in the text
fields and press ‘OK’.
Meshing the slabs
To mesh the shear wall, first clear the previous selections by clicking on from the
left hand side toolbar. Then, select all the area objects assigned with slab property from
every floor by clicking ‘Select’ menu>’by Wall/Slab/Deck Sections…’. In the
‘Select’ box of the resulting ‘Select Sections’ window, select ‘S230’ and press ‘OK’.
This selects all sections which were assigned with ‘S230’ section property. These
sections are of course the slab sections. Then click on ‘Assign’
menu>’Shell/Area’>’Area Object Mesh Options…’ and the following ‘Area Object
Auto Mesh Options’ window will appear

36 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 26
In this window, we will modify the options in the ‘Floor Meshing Options’ box since
we don’t have ramps and the wall meshing is already done. In this box, the ‘Default
(Auto Mesh at Beams and Walls if Membrane - No Auto Mesh if Shell or Plate)’
option meshes the objects at beams and walls, thereby transferring loads, as appropriate,
to and from beams and walls. If the object has been defined as a shell or plate, the
selected objects will not be meshed, thereby treating the object as a Structural Element.
‘For Defining Rigid Diaphragm and Mass Only (No Stiffness - No Vertical Load
Transfer)’ option is selected if it is desired that no stiffness or vertical load transfer
associated with these objects will be considered during the analysis. ‘No Auto Meshing
(Use Objects as Structural Elements)’ option tags the area object to not be
automatically meshed by ETABS into the analysis model, thereby treating the object as
a Structural Element. The ‘Auto Mesh Object into Structural Elements’ option
allows control of meshing according to the following:
• ‘Mesh at Beams and Other Meshing Lines’ option is similar to the
default option.
• ‘Mesh at Wall and Ramp Edges’ option meshes the selected object at
wall and ramp edges, thereby transferring loads, as appropriate, to and
from wall and ramp edges.
• ‘Mesh at Visible Grids’ option meshes the selected objects at grid lines
used in the model.
• ‘Further Subdivide Auto Mesh with Maximum Element Size of
{specify value}’ option meshes the selected object(s) using the specified
maximum element size.
37 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Among these options, the viable option for this example is the four options and set the
preferences as shown in Fig. 26 and press ‘OK’.
To view the meshing, click on and check on ‘Auto Area Mesh’ in the ‘Other
Special Items’ box of the resulting window.
Assigning Diaphragm
Diaphragms are used to connect all individual members on a given floor and create a
single lateral load resisting unit. ETABS uses two types of diaphragms: rigid and semi-
rigid. If you assign a rigid diaphragm to the building, all the constrained joints will move
together a planar diaphragm that is rigid against membrane deformation. While Semi-
rigid diaphragms give the building the ability to behave as its actual behavior. Thus, it
is recommended to use semi-rigid diaphragms in ETABS.
To assign a semi-rigid diaphragm for the model, select the whole building by clicking
on from the left hand side tool bar. Then click on ‘Assign’
menu>’Shell/Area’>’Diaphragms…’ and the following ‘Assign Diaphragm’ will
appear.

Figure 27
In this window, highlight ‘D1’ and click on ‘Modify/Show Diaphragm’ button and
the following winding will appear.

Figure 28

38 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

In the window shown in Fig. 28, select the ‘Semi Rigid’ radio button in the ‘Rigidity’
box and click ‘OK’ in both windows. This assigns semi rigid diaphragms for each floor
with a different name.
2.6. Define Load Cases and Load Combinations

Defining Load Cases


There will be four types of static load cases which will be defined. These are dead loads,
live loads, earthquake loads and wind loads. The dead loads are of two types: self-weight
and wall load on external beams. To define these loads, click on ‘Define’ menu> ‘Static
Load Cases…’ or click on the equivalent menu from the toolbar below the menu
bar and the following ‘Define Static Load Case Names’ window will appear.

Figure 29
In this window, dead and live loads are already defined as ‘DEAD’ and ‘LIVE’
respectively. The ‘Self Weight Multiplier’ for the dead load is 1 while for live load is
0. This should be as it is because the self-weight of the building should be included in
the dead load by making the multiplier as 1. Thus, the load case named ‘DEAD’ will be
used to consider the self-weight of the building. But, there is also another dead load
apart from self-weight, i.e. the wall load. This load will be defined as super imposed
dead load with 0 self-weight multiplier. Making the ‘Self Weight Multiplier’ 0 excludes
the effect of self-weight of the building from the load case. To define another load, you
will click on ‘Add New Load’ button. If you want to modify an already defined load,
you will highlight the load and click on ‘Modify Load’ and modify it. You can also
delete a load once it is defined by highlighting it and clicking the ‘Delete Load’ button.
Defining Wall Load
To define the wall load, write the name of the load in the ‘Load’ column. We will call
the load name as ‘WALL’. From the drop-down menu in the ‘Type’ column, select
‘SUPER DEAD’ since the load type is of a super imposed dead load. The ‘Self Weight
Multiplier’ for this load should be set to 0 because the self-weight is already considered

39 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

in the load case named ‘DEAD’. Then click on the ‘Add New Load’ button. This adds
a load case named ‘WALL’ to the list of pre-defined load cases.
Defining Earthquake Load
To define an earthquake load, write the name of the load in the ‘Load’ column.
Earthquake load for the building will be considered in both x and y-directions. Thus,
we will define two earthquake loads and we will name them ‘EQX’ and ‘EQY’. To
define the earthquake load in x-direction, in the text field of ‘Load’ column of the
window shown in Fig. 29, write ‘EQX’ and from the drop-down menu below ‘Type’
select the load type, for earthquake loads it will be ‘QUAKE’. The self-weight multiplier
should be set to 0. From the drop-down menu in the ‘Auto Lateral Load’, select
‘EUROCODE8 2004’ because the Ethiopian code has closer earthquake analysis to
Eurocode from the given lists and because the earthquake load will be loaded
automatically by the program. If you don’t want the earthquake load to be loaded
automatically, select ‘None’ and you can assign it on the frames manually. Then click
on ‘Add New Load’ button. This adds an earthquake load named EQX to the list of
load cases. Now, you can observe that the ‘Modify Lateral Load…’ button becomes
active when you highlight the ‘EQX’ load case. By clicking this button, you can modify
some of the parameters regarding the earthquake load. When you click this window,
the following ‘2004 Eurocode8 Seismic Load Pattern’ window will appear.

Figure 30
In the ‘Direction and Eccentricity’ box, select the ‘X Dir+ Eccen Y’ radio button
since EQX is earthquake load in x-direction. From the second and the third radio
buttons, the ‘+’ or ‘-‘ sign can be used consistently. But the better option is to define
two earthquake loads in x-direction: one with ‘+’ sign and another with ‘-‘ sign. For this
40 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

example, we will use the ‘+’ sign consistently. The ‘Ecc. Ratio (All Diaph.)’ value
should be 0.05. In the ‘Time Period’ box, select the ‘Program Calc’ radio button. And
from ‘Story Range’ box, select the two extreme stories because we will be applying the
earthquake load for all stories. In the ‘Parameters’ box, the values should be as shown
in Fig. 30 for a multi-purpose building founded on black cotton soil. Then press ‘OK’.
After this, the earthquake load in y-direction will be defined following the same
procedure.
Defining Wind Load
To define a wind load, write the name of the load in the ‘Load’ column. Wind load for
the building will be considered in both x and y-directions. Thus, we will define two wind
loads and we will name them ‘WINDX’ and ‘WINDY’. To define the wind load in x-
direction, in the text field of ‘Load’ column of the window shown in Fig. 29, write
‘WINDX’ and from the drop-down menu below ‘Type’ select the load type, for wind
loads it will be ‘WIND’. The self-weight multiplier should be set to 0. From the drop-
down menu in the ‘Auto Lateral Load’, select ‘EUROCODE1 2005’ because the
Ethiopian code has closer earthquake analysis to Eurocode from the given lists and
because the wind load will be loaded automatically by the program. If you don’t want
the wind load to be loaded automatically, select ‘None’ and you can assign it on the
frames manually. Then click on ‘Add New Load’ button. This adds a wind load named
WINDX to the list of load cases. Now, you can observe that the ‘Modify Lateral
Load…’ button becomes active when you highlight the ‘WINDX’ load case. By
clicking this button, you can modify some of the parameters regarding the wind load.
When you click this window, the following ‘Eurocode1 2005 Wind Loading’ window
will appear.

41 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 31
In the ‘Exposure and Pressure Coefficients’ box of the above window, there are two
radio buttons. The ‘Exposure from Extents of Rigid Diaphragms’ radio button
allows the same wind load to be applied each time the load case is assigned. When
‘Exposure from Area Objects’ option is checked, the ‘Wind Exposure Parameters’
box becomes inactive. This option allows wind load coefficients and wind direction to
be applied on an area-object-by-area-object basis. Thus, if this second option is selected,
there is an additional task of selecting area objects where the wind load will be applied
from the model and defining pressure coefficients for the selected area objects until all
the area objects subjected to wind loading are assigned with appropriate pressure
coefficients. The first option is simpler and will be applied for this example. In the
‘Wind Exposure Parameters’ box, there are three parameters which need to be set.
The ‘Wind Direction Angle’ may be one of the adverse wind direction angles which
are used for design purposes. These angles are 0, 90, 180…. What you have to bear in
mind is, if you use 0 for ‘WINDX’, you have to use 90 for ‘WINDY’ and vice versa.
Here, we use 0 for ‘WINDX’. The other values in this box and ‘Wind Coefficients’ box
are determined from EBCS-1 and Eurocode 1 for the building data given earlier. In the
‘Exposure Height’ box, select the stories which are exposed to wind loading. These
are STORY1 to STORY12. Then, click ‘OK’. The wind load in y-direction should also
be defined by the same procedure. The only difference will be the value of the ‘Wind
Direction Angle’ in the ‘Wind Exposure Parameters’ box will be 90. After defining
all the load cases, the ‘Define Static Load Names’ window shown in Fig. 29 should
look like:
42 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 32
Click ‘OK’ in the above window to finalize the definition of static load cases.
Defining Load Combinations
After the loads are defined, the load combinations for ultimate and serviceability limit
states will be defined. The partial safety factors which will be used for both limit states
are given in the design aid of EBCS-2. These values are as belows:

There will be six ultimate limit state (ULS) load combinations and two serviceability
limit state (SLS) load combinations. In all these load combinations, there are two or
more load cases which will be linearly added. In the above table, the dead load
represents both the self-weight and super imposed dead loads combined. Thus,
whenever the load case named ‘DEAD’ is included in a load combination, the load case
named ‘WALL’ should also be included with the same partial safety factor. It should
be noted that while including lateral loads in the load combinations, both + and –
directions should be considered. Besides these load combinations, another load
combination which extracts the maximum effects of all the above load combinations
should be defined as an envelope.

43 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

To define the load combinations, click on ‘Define’ menu>’Load Combinations’


command or click on the equivalent button from the toolbar below the menu bar
and the following ‘Define Load Combinations’ window will appear.

Figure 33

In the ‘Click to:’ box of the above window, there are three buttons by which you can
add, modify or delete load combinations. The ‘Modify/Show Combo…’ and ‘Delete
Combo’ buttons become active once a new combination is added.
To add a new load combination, click on the ‘Add New Combo…’ button from the
window shown in Fig. 33. This results in the appearance of the following ‘Load
Combination Data’ window.

Figure 34
In the above window, keep the ‘Load Combination Name’ to be ‘COMB1’ or you
can also change it to any suitable name. The drop-down menu for ‘Load Combination
Type’ should be set to ‘ADD’ as the load cases will be linearly added. To add a particular
44 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

load case for a given load combination, select it from the drop-down menu below ‘Case
Name’, enter the partial safety factor shown in the table above in the text field below
‘Scale Factor’ and click on ‘Add’ button. For the first ULS load combination shown
in the table above, select ‘DEAD Static Load’ from the ‘Case Name’ drop-down
menu, enter 1.3 in the text field below ‘Scale Factor’ and click on the ‘Add’ button.
Next, select ‘WALL Static Load’ from the ‘Case Name’ drop-down menu, enter 1.3
in the text field below ‘Scale Factor’ and click on the ‘Add’ button. Then, select ‘LIVE
Static Load’ from the ‘Case Name’ drop-down menu, enter 1.6 in the text field below
‘Scale Factor’ and click on the ‘Add’ button. This defines the first load combination
where comprised of all the dead and live loads with partial safety factors of 1.3 and 1.6
respectively. If you want to modify or delete any load cases which are incorrectly added
you can use the ‘Modify’ or ‘Delete’ buttons. Clicking ‘OK’ defines a new load
combination and returns to the window shown in Fig.33. You can define another load
combination by clicking the ‘Add New Combo…’ button in Fig. 33. By following the
same procedure, define load combinations for ULS and SLS considering + and –
directions of lateral loads in both x and y-directions. To consider – directions of lateral
loads, just use a negative partial safety factor for the scale factor. There will be 27 of
them including the envelope. The envelope should be created after all the other load
combinations are created. While creating the envelope, the ‘Load Combination Type’
should be set to ‘ENVE’ and all the previous load combinations should be added to
with a scale factor of 1. The ‘Load Combination Data’ windows for one of the second
ULS load combinations and for the envelope are shown in the figures below.

Figure 35

45 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

2.7. Assign Loads

Once the load cases and the load combinations are defined, then the magnitudes of the
loads for those particular cases can be applied (assigned) on the structural elements. All
the wall loads on external beams and live loads should be applied appropriately. All the
lateral loads will be assigned by the program itself. We will start by applying the wall
loads on external beams. Note that the beams along axis B not axis A bear the external
beams.
Assigning Wall Loads

Before assigning the loads on the beams, those beams from all floors on which the load
will be assigned should be selected. But the wall load will not be applied on the roof
floor. Then the load will be assigned. The easiest way to do this is to select all the
external beams for all floors by setting the Similar To drop-down menu in the status bar
to ‘All Stories’ and selecting only the external beams for one floor and apply the load.
But this applies the wall load on the roof floor beams (which shouldn’t be assigned with
any wall load) as well. To cancel this unwanted loading, the external beams for the roof
floor will be selected by setting the Similar To drop-down menu in the status bar to ‘One
Story’ and selecting only the external beams for the roof floor and delete existing loads.

As stated, select all the external beams for all floors by setting the Similar To drop-down
menu in the status bar to ‘All Stories’ and selecting only the external beams for one
floor. The external beams are beams along axis B, axis G, axis 1(between axis B and
axis G) and axis 6(between axis B and axis G). Then click on ‘Assign’
menu>’Frame/Line Loads’ > ‘Distributed…’ or click on the equivalent button
from the toolbar below the menu bar and the following ‘Frame Distributed
Loads’ window will appear.

46 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 36

In this window, the ‘Load Case Name’ should be set to ‘WALL’ and you can select a
suitable unit from the ‘Units’ drop-down menu. Here, we use the ‘KN-m’ unit. In the
‘Load Type and Direction’ box select the ‘Forces’ radio button since we are applying
a force. Had we been applying a moment, we would have selected the ‘Moments’ radio
button. From the ‘Direction’ drop-down menu, select the direction of the load which
you are assigning. The ‘Gravity’ direction represents the downward –ve z-direction and
will be selected for this particular case. In the ‘Options’ box, there are three radio
buttons. You can use, the ‘Add to Existing Loads’ option to add the load that you are
assigning at the moment to previously assigned loads, the ‘Replace Existing Loads’
option to replace any existing loads with the load that you are currently defining or the
‘Delete Existing Loads’ option to delete any previously assigned loads having the
same load case name as the one that is selected in the ‘Load Case Name’ drop-down
menu. If you have a trapezoidal load, the parameters related to the load should be
entered in the text fields inside ‘Trapezoidal Loads’ box. Here, we will not use this
box as our load is a uniform one. Rather, we will use the text field inside the ‘Uniform
Load’ box to enter the magnitude, and possibly the direction, of the load. Since the wall
load is of magnitude 10kN/m, enter 10 in the text field. In this text field, we can enter
negative values to indicate that the loads are directed in the –ve direction of the axes
selected from the ‘Direction’ drop-down menu. Then press ‘OK’.

To delete the wall load on external beams of the roof floor, select ‘One Story’ from the
Similar To drop-down menu, switch to the roof floor in the plan view and select all the
external beams where were previously assigned with wall loading. Then click on
‘Assign’ menu>’Frame/Line Loads’ > ‘Distributed…’. When the ‘Frame
Distributed Loads’ window, shown in Fig. 36 appears, make the same selections as in
47 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

this figure except that the ‘Delete Existing Loads’ radio button in the ‘Options’ box
should be selected. Then press ‘OK’. This deletes the wall loads from the external beams
of the roof floor. If you want to view the loading, you can change one of the windows
to elevation view and click on ‘Display’> ‘Show Loads’ > ‘Frame/Line…’. In the
resulting window, select the appropriate load type from the ‘Load Case’ drop-down
menu , check the ‘Show Loading Values’ and press the ‘OK’ button.

Assigning Live Loads

Slabs

To assign live loads to the slabs, the slabs should be selected first. The slabs from the
first to the fifth floor are loaded with a live load of 3kN/m2 and the slabs from the sixth
to the tenth floor are loaded with a live load of 5kN/m2. The roof floor slabs are loaded
with a live load of 1kN/m2. Note that slabs from first to fifth floors are similar and
likewise for the slabs from the sixth to tenth floors.

To assign the live loads on the slabs from the first to the fifth floors, set the Similar To
drop-down menu to ‘Similar Stories’, switch to the first floor (STORY 2) and select
all the slabs (including those slabs with openings) by clicking on them. The left hand
side of the status bar should show ‘150 Areas, 555 Edges selected’. Then click on
‘Assign’ menu> ‘Shell/Area Loads’> ‘Uniform…’ and the following ‘Uniform
Surface Loads’ window will appear.

Figure 37

In this window, set the ‘Load Case Name’ to ‘LIVE’ and the ‘Units’ to ‘KN-m’. In
the ‘Uniform Load’ box, the value of ‘Load’ should be ‘3’ and the ‘Direction’ should
be ‘Gravity’. In the ‘Options’, you can select the ‘Add to Existing Loads’ or ‘Replace
Existing Loads’ option without bringing any change since there are no pre-defined
‘LIVE’ loads. Then press ‘OK’.
48 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

In a similar manner, you can assign the slabs from sixth to tenth floors with a live load
of 5kN/m2 and the roof floor slabs with a live load of 1kN/m2.
Internal Beams

To assign live loads to the internal beams, the beams should be selected first. The
internal beams from the first to the fifth floor (having a width of 0.3m) are loaded with
a live load of 3*0.3=0.9kN/m and the beams from the sixth to the tenth floor (having
a width of 0.25m) are loaded with a live load of 5*0.25=1.25kN/m. The roof floor
beams (having a width of 0.25m) are loaded with a live load of 1*0.25 = 0.25kN/m.
Note that beams from first to fifth floors are similar and likewise for the beams from
the sixth to tenth floors.

To assign the live loads on the slabs from the first to the fifth floors, set the Similar To
drop-down menu to ‘Similar Stories’, switch to the first floor (STORY 2) and select
all the internal beams (beams inside the external beams) by clicking on them. The left
hand side of the status bar should show ‘200 Lines selected’. Then click on ‘Assign’
menu> ‘Frame/Line Loads’> ‘Distributed…’ and the following ‘Frame
Distributed Loads’ window will appear.

Figure 38

Then set the all the parameters as shown in Fig. 38 and press ‘OK’. In a similar manner,
you can apply the live loads on the internal beams from the sixth to the tenth floors
and on the roof floor.

49 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Stairs and Landings

To assign live loads to internal beams and landings, select all the landings and the stairs
from both staircases of all floors one by one and apply a live load of magnitude 5kN/m2
in the same way you applied the live loads for slabs. Note that to select the flights, you
need to change one of the windows to an appropriate 3-D view.

2.8. Assign Pier Labels

Design of walls cannot be performed unless they have their own pier or spandrel ID.
Thus, it is desirable to assign piers and spandrels with a unique name. In this example,
the existing walls are the shear walls for the elevators and all of them were defined as
piers.

To assign the shear walls with their own labels, select each shear wall (one at a time)
and click on ‘Assign’ menu>’Shell/Area’>’Pier Label…’ and the following ‘Pier
Names’ window will appear.

Figure 39

Then, in the text field inside the ‘Wall Piers’ box, write any name which you want and
click on ‘Add New Name’ button. Clicking the ‘OK’ button assigns that new name to
the selected pier. Do this for all walls and the ‘Pier Names’ window will look like as
shown in Fig. 39.

50 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

2.9. Define Mass Source and Autoline Constraints

Mass Source

By defining the mass source, we will define the percentage of the dead and live loads
contributing for the earthquake load calculations. EBCS-8 suggests that the whole dead
load and a live load multiplied by coefficient for quasi permanent value of variable
action should be used as a mass source for earthquake load calculations. The code also
suggests that the value of the coefficient for quasi permanent value of variable action
can be conservatively taken as unity. Thus, 100% of both the dead loads and the live
loads will be considered as a mass source.

To define a mass source, click on ‘Define’ menu> ‘Mass Source’ and the following
‘Define Mass Source’ window will appear.

Figure 40

In this window, there are three radio buttons in the ‘Mass Definition’ box. Each
structural element has a material property associated with it. One of the items specified
in the material properties is a mass per unit volume. When ‘From Self and Specified
Mass’ radio button is selected, ETABS determines the building mass associated with
the element mass by multiplying the volume of each structural element times its
specified mass per unit volume. When ‘From Loads’ radio button is selected, ETABS
51 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

determines a mass by dividing the defined load combination by acceleration due to


gravity. The load combination can be defined in the ‘Define Mass Multiplier for
Loads’ box. The ‘From Self and Specified Mass and Loads’ option is used to
combine the above two options. Since we have both self-weights of structural elements
and walls and live loads, the third radio button will be selected.

Then in the ‘Define Mass Multiplier for Loads’ box, select a load from the ‘Load’
column and enter an appropriate multiplier (all one in this case) from the ‘Multiplier’
column and click the ‘Add’ button. In this manner, add all the loads (DEAD, WALL
and LIVE) in the vertical direction.

The ‘Include Lateral Mass Only’ check box is used to include or exclude vertical
dynamics in the model. If it is checked, the vertical dynamics will not be included in the
model. In our model, we will not include vertical dynamics and the box should remain
checked. The ‘Lump Lateral Mass at Story Levels’ option "moves" lateral mass that
may occur between story levels to the nearest story level during analysis. This option
can be used in conjunction with the default (i.e., From Self and Specified Mass option
for which the total mass is applied to each joint in the structure on a tributary area basis
in all three translational directions) and with the Include Lateral Mass Only option. This
box should also remain checked.

Then, click ‘OK’ in the window shown in Fig. 40.

Auto Line Constraints

Auto line constraints automatically connects adjacent elements that do not share
common joints. Typically in finite element analysis, shell elements are connected to
other elements at corner points only. When an element does not frame into the corner
point of a shell element, but instead frames into the edge of the shell element, no
connection exists between the element and the shell element. The ETABS auto line
constraints feature allows you to specify that elements framing into the edge of a shell
element be connected to the shell element. ETABS internally takes care of connection
between the elements by constraining points lying along an edge of the shell element to
move with that edge of the element.

To assign an auto line constraint, select the whole model and click on ‘Assign’
menu>’Shell/Area’>’Auto Line Constraint…’ and the following ‘Auto Line
Constraint Options’ window will appear.

52 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 41

In the above window, when the ‘Do NOT Create Line Constraints’ radio button is
selected, ETABS will not constrain points along the edges of the shell elements to move
with the edges of another element. Use this option to remove existing auto line
constraint assignments. The ‘Create Line Constraints around’ radio button is used to
create constraints around either ‘Walls and Ramps’ or ‘Floors’ or both. When the
‘Apply to Full Structure (not just Selection)’ check box is checked, ETABS applies
the option(s) selected on window shown in Fig. 41 to the entire structure rather than
just to the selected area object(s). By default, this check box is checked. Therefore, if
you want to apply the line constraint to selected area objects only, uncheck this check
box. In this example, we will create constraints around walls and floors for the entire
model. Thus, the default selections shown in Fig. 41 will be enforced. Lastly, click ‘OK’
button to finalize the auto line constraint assignment.

2.10. Assign the Supports

The building is assumed to have a fixed support at the foundations and the stairs are
assumed to have a pin support. Thus, all the points at the base of the model will be
assigned with fixed support. Similarly, all the points on the flights and landings will
assigned with pin supports.

To add fixed supports at the base of the model, switch to base of the model on the plan
view. If the base is active, the title of the window should show ‘Plan View –Base –
Elevation 0’. Then make a rubber band selection to select all the points on the base.
Then, click on ‘Assign’ menu > ‘Joint/Point’ > ‘Restraints (Supports)…’ and the
following ‘Assign Restraints’ window will appear.

53 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 42
In the above window, the check boxes in the ‘Restraints in Global Directions’ box
identify the six possible degrees of freedom available for a point object. When a check
box is checked, that degree of freedom is restrained. When a check box is unchecked,
that degree of freedom will be unrestrained. The buttons in the ‘Fast Restraints’ box
are used to quickly set the restraint conditions. Note that when one of the buttons is
checked, the check boxes in the Restraints in Global Directions area of the form
become checked or unchecked, depending on the selection made. The fixed base
restraints button is used to restrain all six degrees of freedom. The pinned support
button is used to restrain all three translation degrees of freedom and to specify
that all three rotation degrees of freedom be unrestrained. The roller support button
is used to restrain only the Z translation. All other degrees of freedom are
unrestrained. The no support button is used to specify that all degrees of freedom
are unrestrained.

Since we are assigning a fixed support to the base, click on the fixed support button
and click ‘OK’.
To assign a pin support to the stairs, select all the points on the flights and landings
from all floors for both staircases. Then, click on ‘Assign’ menu > ‘Joint/Point’ >
‘Restraints (Supports)…’ and select the pinned support button from resulting
window and press ‘OK’.

2.11. Check the Model and Run Analysis

At this stage, the modelling is complete. However, it is recommended to check the


model for any errors. To do this, click on ‘Analyze’ menu> ‘Check Model…’ and the
following ‘Check Model’ window will appear.
54 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 43
In this window, check all the check boxes and click ‘OK’. Not that the ‘Selected
objects only’ check box is not active unless you selected any element from the model.
If there are no errors nor warnings in the model, the following message will be
displayed.

Figure 44

55 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

If there is any error or warning, ETABS can pin point the location of the problem for
you and may direct you with the actions which you need to take to correct it. You can
do this by selecting the whole model and clicking on the ‘Analyze’ menu> ‘Check
Model…’. In the resulting window, at this time, the ‘Selected objects only’ check box
will become active. Check this box and press ‘OK’. The program will pin point the
location of the error and direct you with actions to solve the error.

If there are no errors in the model, you can run the analysis of model by clicking on
‘Analyze’ menu > ‘Run Analysis’ or by clicking the equivalent button from the
tool bar below the menu bar.

3. Display the Results

Displaying the analysis results is vital in the design of high rise buildings. Any
unreasonable results can be investigated and corrective measures can be taken after the
results are displayed. There are two ways of displaying ETABS analysis results: tabular
method and graphical method. Each of these methods will be discussed one by one in
the next sections.

3.1. Tabular Display

The most important tabular review for the result is the summery report. This report
gives you the important information about the model and analysis results. To get the
summary report click on ‘File’ menu> ‘Print Tables…’>’Summary Report’ which
results in the appearance of the following ‘Print Summary Report’ window.

Figure 45
In this window, click on the ‘File Name…’ button while the ‘Print to File’ check box
is checked. This prompts you to save the report anywhere in your computer with any
file name. Save the file in your computer and you can access it anytime you want. As
can be noted, the summary report includes important information regarding the model
and analysis results.

56 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

You can also get all the analysis output in a tabular form by clicking on ‘File’ menu>
‘Print Tables…’>Analysis Output…’ and the following ‘Print Analysis Output’
window will appear.

Figure 46

In this window, you select the type of outputs and the corresponding load combinations
you want to display from the ‘Type of Analysis Results’ box. The load combinations
for which the result will be displayed can be selected by clicking on the ‘Select
Loads…’ button. The drop-down menu in the ‘Print Sort Order’ box is used to choose
the order of the print out based on ‘Stories’, ‘Objects’ or ‘Loads’. If ‘Loads’ is
selected, use the Second drop-down list to specify ‘Stories’ or ‘Objects’ as a second
sorting criterion. The ‘Print to File’ check box is checked if it is desired to print the
specified data to a text file. The ‘Append’ check box is checked to add the specified
data to an existing file. The ‘Selection Only’ check box becomes active if point, line or
area objects were selected before the ‘File’ menu > ‘Print Tables’ > ‘Analysis Output’
command was selected; only data for the selected objects will be include in the printed
output. Unchecking this check box will cause data for all objects in the model to be
included in the printed output. When the ‘Envelopes Only’ check box is checked only
envelopes (i.e., minimums and maximums) for the specified data will be provided as the
analysis output.

ETABS has also an option to display the results on the screen without saving any file
and a possibility to export the results. To display the results on the screen, there are two
57 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

options. The first option is to click on ‘Display’ menu>’Show Tables…’. The second
option is to click on ‘File’ menu> ‘Export’ > ‘Save Input/Output as Access
Database File’. When the first option is selected clicking the ‘OK’ button will display
the database table for the selected data types. However, if the second option is followed,
clicking the ‘OK’ button will display the ‘Save Access Database File As’ window. Use
this window to specify the path and file name to save the input/output data to an Access
database. Both options result in the following ‘Show Tables for Display’ window will
appear.

Figure 47

In the above window, the ‘Select Load Cases’ button to access the ‘Select Load
Conditions’ window. Highlight the load cases to be included in the display or export.
Click the ‘Clear All’ button on that window to exclude data for all load cases. The
‘Select Cases/Combos…’ is used to display the ‘Select Load Cases/Combos
(Results)’ window. Use that window to select the load cases and load combinations to
be included in the display of tables. The ‘Modify/Show Options…’ button is used to
display the ‘Output Options’ window. Use the form to specify how the analysis results
58 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

will be displayed depending on the type of analysis (e.g., Envelopes, Step-by-Step and
so on).After the other options have been set on the window, click the ‘Save Named
Set’ button to display the ‘Database Table Named Sets’ window. Use the form to
add, modify or delete a named set. A named set is the settings specified on the form.
Saving those settings allows them to be easily recalled using the ‘Show Named Set’
button and applied to another display or export.

For instance, for all load cases and for design combo of ‘COMB27’, the support
reaction forces can be displayed by selecting the options shown in the figure below.

Figure 48
The displayed output for the above selection will look like:

59 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 49

3.2. Graphical Display

The analysis results can also be displayed graphically. Quantities such as reactions, shear
forces, bending moments, axial forces, torsions and displacements can be displayed
graphically.
Displaying Reaction Forces
To display reaction forces, you can use any of the plan, elevation or 3-D views.
However, the plan view imparts a comprehensive view of reaction forces on a given
floor. Particularly, the base reactions may have more importance as they will be used in
the design of foundations. To view the reaction forces at the base, switch to the base
on the plan view and click on ‘Display’ menu > ‘Show Member Forces/Stress
Diagram’ > ‘Support/Spring Reactions…’ and the following ‘Point Reaction
Forces’ window will appear.

Figure 50

60 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

In the above window, the drop-down menu for ‘Load’ consists of load cases and load
combinations for which we want to display the reaction forces. The load combination
‘COMB27’ might be of distinctive importance as it envelops all the other load
combinations. Thus, it will be selected. The ‘Type’ box consists of two radio buttons.
The ‘Reactions’ radio button is used to display reaction forces while the ‘Spring Forces’
radio button is used to display spring forces, if there are any. In this example, we don’t
have any springs and the reaction forces at any of the supports will be displayed by
selecting the ‘Reactions’ radio button and pressing the ‘OK’ button. This results in the
following base reactions. Right clicking on any of the supports displays a summary of
the support reactions in a tabular form. In the figure below the summarized reactions
are for the support at the intersection of axis 4 and axis C.

Figure 51

Displaying Member Forces


To display the member forces, you can use any of the plan, elevation or 3-D views.
Here, we will use the elevation view. For this, change one of the views of the windows
61 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

to elevation view. To display the member forces, click on ‘Display’ menu > ‘Show
Member Forces/Stress Diagram’ > ‘Frame/Pier/Spandrel Forces…’ and the
following ‘Member Force Diagrams for Frames’ window will appear.

Figure 52
In the above window, you can select any load case or combination from the ‘Load’
drop-down menu and any member force you want to display from the radio buttons in
the ‘Component’ box. The shear forces and moments can be displayed in two different
local axes of the member: 2-2 and 3-3. The local axis 2 for horizontal elements such as
beams is perpendicular to the beam and is in the same direction as the global z-axis.
The local axis 3 for horizontal elements is also perpendicular to the beam but it is
horizontal. Thus, the shear force along local axis 2 (‘Shear 2-2’) and the moment about
local axis 3 (‘Moment 3-3’) may be of importance for design purposes. The ‘Inplane
Shear’ and ‘Inplane Moment’ radio buttons can also be used display these shear forces
and bending moments. The radio buttons in the ‘Scaling’ box provide with an option
for an automatic or manual scaling of the displayed graphical results. If the ‘Auto’ radio
button is selected, ETABS will scale the displayed graphics automatically. However, if
the automatic scale factor seems to cause a display problem, specify your own factor by
selecting the ‘Scale Factor’ radio button. The ‘Options’ box contains two check boxes.
Check or uncheck the check boxes to display the force diagrams filled with no text
62 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

values or unfilled with text values. The ‘Fill Diagram’ check box will be used if it is
desired that the displayed graphical results will be displayed with a filled diagram. Note
that if the ‘Show Values on Diagram’ check box is currently checked you must
uncheck it first before you can check the ‘Fill Diagram’ check box. When the ‘Show
Values on Diagram’ check box is selected the values will be displayed in the graphical
result. Note that if the ‘Fill Diagram’ check box is currently checked, you must
uncheck it before you can check the ‘Show Values on Diagram’ check box. Leave
both check boxes unchecked to display the form diagrams unfilled with not text values.
You can select any element type for which the results will be displayed by checking the
check boxes in the ‘Include’ box. For frames, the ‘Frames’ check box will be checked
and for walls, the ‘Piers’ or ‘Spandrels’ check box may be checked. Depending on this
selection, clicking the ‘OK’ button will generate the member forces for frames or walls
or both
For the selections shown in Fig. 52, the results are shown in the figure below. Right
clicking on any of the members will display the details of the selected quantity for that
particular member.

Figure 53
In the window shown in Fig. 52, if you choose any load case or non-enveloping load
combination and if you click on any beam you will see a detailed information as in the
figure below.
63 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 54
The ‘Load’ drop-down menu imparts you with options to choose any load case or any
non-enveloping load combination for which you are going to display the results for one
of the selected quantities in the ‘Component’ box of Fig. 52. The ‘End Length Offsets
(Location)’ box contains two buttons: ‘I-End’ and ‘J-End’ designating the two ends
of the member. The numbers written in front of the buttons are the distances from the
ends of the member to the face of the supports for those particular joints. The numbers
in brackets are the distances of the offset points from ‘I-End’ of the member. If you
click on any of these buttons, the values of the loads, shears, moments and deflections
corresponding to the offset point for that particular joint will be displayed in the
diagrams embedded in Fig. 54. The ‘Display Options’ box contains two radio buttons.
The ‘Scroll for Values’ radio button will be selected if it is desired to display the
quantities along any section of the member by using a scroll bar which will appear in
the window when this radio button is selected. The ‘Show Max’ radio button will be
used if it is desired to display the maximum value of the quantities at the sections where
they occur. The ‘Deflections’ box contains four radio buttons as the deflections of the
member can be given relative to other values. The ‘Absolute’ radio button will be
selected to display the absolute deflection at any section of the member with respect to
the global reference axis. When the ‘Relative to Beam Minimum’ radio button is
64 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

selected, the deflection at any section relative to the minimum deflection on the member
itself will be displayed. When the ‘Relative to Beam Ends’ radio button is selected,
the deflection at any section relative to the end deflections on the member itself will be
displayed. The ‘Relative to Story Minimum’ radio button will be selected to display
the deflection at any section of the member with respect to the minimum deflection
across the story. The ‘Units’ drop-down menu provides with options to display the
quantities in different units. Clicking the ‘Done’ button exists the window.

4. Section Design
The design of structural members is more sensitive to code differences than the analysis
part. As a result, section designs may not be performed by ETABS for buildings to be
constructed in countries where their building codes are not pre-defined in ETABS
program and possess considerable differences with the pre-defined codes. However,
the ETABS section designs may be useful to check the consistency of ETABS-designed
sections and section designs by other applicable approaches. Thus, the design of
concrete frames and shear walls will be discussed in the next sub-sections.

4.1. Concrete Frame Design

The concrete frame includes beams, columns and stairs. The design of these structural
components for flexure, shear and torsion will be discussed next.

The first step in the design of frames or walls is to adjust the design codes which will
be used for the design of the sections. For this example, this task has already been done
in section 2.2 of this tutorial and there is no need of repeating it here. However, if you
haven’t adjusted the design code to your preferred code, it is high time performing this
task. Just follow the procedures stated at the beginning of section 2.2.

Before starting the design process, the load combinations for which the design will be
executed should be selected. Otherwise, the program uses the default load
combinations in the program for design purposes. To select the load combinations for
concrete frame design, click on ‘Design’ menu > ‘Concrete Frame Design’ > ‘Select
Design Combo…’ and the following ‘Design Load Combination Selection’
window will appear.

65 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 55

In the above window, the list in the ‘List of Combos’ left hand side list box contains
list of load combinations which were defined in section 2.6. The default design
combinations are listed in the ‘Design Combos’ list box in the right hand side of the
window. Since we don’t need these default design combinations, remove them from
this right hand side list box. To do this, select all of them by holding down the shift key
and click on the ‘<- Remove’ button. Taking great care not to include the default load
combinations which were just removed from the right hand side list box, add all the
load combinations which were in the left hand side list box to the design combos by
selecting all of them and clicking the ‘Add ->’ button. Click ‘OK’ when you finish
adding the desired load combinations.

To design the frame sections, activate the window containing the plan view and click
on ‘Design’ menu > ‘Concrete Frame Design’ > ‘Start Design/Check of
Structure’ or click on the equivalent button and the program will perform the
design process automatically.
When the program finishes the designing, you will see reinforcement area values for all
concrete frames on the plan view. If all the values are zero, this is due to the units and
change the units from the task bar at the bottom right corner of the window to ‘KN-
mm’ or other applicable unit. For the first floor beams, the result looks like as in the
figure below. As can be noted, the reinforcement values for beams, which are in mm2,
are given at three points (left, middle and right) for the top and bottom reinforcements.
For columns, only one reinforcement value will be given.

66 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 56

Right clicking on any the beams in the above figure results in detailed design
information for that particular beam. A sample is shown in the figure below.

67 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 57

In the above window, the top and bottom flexural reinforcements and shear
reinforcement ratios for different load combinations are given at different sections of
the beam. The values in the ‘STATION LOC’ give the distances, in mm, of the section
from one end of the beam. There are three buttons at the bottom of the window. When
you click on the ‘Overwrites’ button, you will be provided with possibilities to
overwrite some of the design parameters used in the design of that particular member
and re-design it. When this button is clicked the following ‘Concrete Frame Design
Overwrites (BS8110 97)’ window will appear.

Figure 58
In the above window, you can change the values of the listed parameters and re-design
the beam. But, to change the value of a parameter, you have to check the check box in
front of that parameter. For instance, in the above figure, the ‘Element Section’ (which
was originally ‘RB300X500’) is changed to ‘RB250X400’. Clicking the ‘OK’ button will
display the new design of the beam persistent to the change which was just made. While
68 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

designing, you may observe that some sections being inadequate or too conservative
and you may need to change their sectional properties. In such cases, the section
corresponding to the ‘Element Section’ in Fig. 58 will be changed and the frame will
be re-analyzed. ETABS can assign the new sections automatically before the re-analysis.
In order to do this, after changing the sections, ‘Design’ menu > ‘Concrete Frame
Design’ > ‘Verify Analysis vs Design Section…’ and a window will appear
prompting you to confirm the selection of the frame sections which will be
automatically changed to the new sections during the analysis. If you want to re-analyze
the model, you need to unlock the model first by clicking on ‘Options’ menu > ‘Lock
Model’ or by clicking the equivalent ‘Lock/Unlock Model’ button from the
tool bars below the menu bar.
In the window shown in Fig. 57, clicking the ‘Summary’ button gives a summarized
information about the design results for the highlighted load combination and
‘STATION LOC’. In the same figure, clicking the ‘Envelope’ button, displays a
summarized information about the maximum + and – flexural reinforcements, bending
moments, shear reinforcements and shear force values and the corresponding
controlling load combinations across the selected beam. Clicking the ‘OK’ button in
this window, terminates the display of the design information.
The ‘Design’ menu> ‘Concrete Frame Design’ >’Display Design Info…’
command, which results in the window shown below, provides with an option which
quantity to display.

Figure 59
In the above figure, you can select a quantity to display by selecting it from the drop-
down menu of ‘Design Output’ radio button. Clicking the ‘OK’ button displays the
quantity on the highlighted window.

4.2. Shear Wall Design

Before designing the shear wall, the best design code which will be used for the design
should be set. To do this, click on ‘Options’ menu> ‘Preferences…’> ‘Shear Wall

69 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Design…’ and the following ‘Wall Pier/Spandrel Design Preferences’ window will
appear.

Figure 60

Set the preferences as in the above window. ‘BS8110 97’ is selected as the ‘Design
code’ because the Ethiopian Building Code Standard (EBCS-2) is much similar to this
British Standard.

Before starting the design process, the load combinations for which the design will be
executed should be selected. Otherwise, the program uses the default load
combinations in the program for design purposes. To select the load combinations for
concrete frame design, click on ‘Design’ menu > ‘Shear Wall Design’ > ‘Select
Design Combo…’ and the following ‘Design Load Combination Selection’
window will appear.

Figure 61
70 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

In the above window, the list in the ‘List of Combos’ left hand side list box contains
list of load combinations which were defined in section 2.6. The default design
combinations are listed in the ‘Design Combos’ list box in the right hand side of the
window. Since we don’t need these default design combinations, remove them from
this right hand side list box. To do this, select all of them by holding down the shift key
and click on the ‘<- Remove’ button. Taking great care not to include the default load
combinations which were just removed from the right hand side list box, add all the
load combinations which were in the left hand side list box to the design combos by
selecting all of them and clicking the ‘Add ->’ button. Click ‘OK’ when you finish
adding the desired load combinations.

There are three methods which are available in ETABS for design of shear walls. These
are: Simplified C and T section method, Uniform reinforcing pier section method, and
General pier reinforcing section method. The Simplified C and T Section method is a
very simple method for design but assumes as if the shear wall sections are planar. This
method can only be used for design of shear walls. It cannot be used for checking the
adequacy of the sections or reinforcement. The Uniform reinforcing pier section
method is the most widely used method for design of shear walls. It can be used for
both designing and checking of shear wall sections. The General pier reinforcing section
method is the most accurate method but it requires additional task of drawing all the
wall sections and their reinforcement. For this example, the uniform reinforcing pier
section method will be used.

To select the method of design, select the whole shear wall by clicking on ‘Select’ menu
> ‘by Wall/Slab/Deck Sections…’ and highlight ‘SW300’ from the resulting window
and press ‘OK’. Then click on ‘Design’ menu > ‘Shear Wall Design’ > ‘Assign Pier
Sections for Checking’ > ‘Uniform Reinforcing Pier Section’ resulting in the
appearance of the following ‘Uniform Reinforcing Assignment to Pier’ window.

71 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 62

In the above window, set the value of ‘Material’ to ‘C30’, the ‘Clear Cover for Rebar’
to ‘0.025’. The value of ‘Bar Size’ and ‘Spacing’ can be any appropriate values. If it is
desired to check the adequacy of the sections, the ‘Reinforcement to be Checked’
radio button in the ‘Check/Design’ box will be selected. To design the sections the
‘Reinforcement to be Designed’ radio button will be selected. When you finish click
the ‘OK’ button.

Change one of the windows to one of the elevation views consisting of the shear wall
and start the design process by clicking on ‘Design’ menu > ‘Shear Wall Design’ >
‘Start Design/Check of Structure’. When the design is finished, the reinforcement
ratios will be displayed on the shear walls. If you select any shear wall ( zooming in may
be necessary) and right click on the selected shear wall a window with summarized
information about the flexural and shear reinforcement and shear and moment values
will appear. A sample is shown in the figure below.

72 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 63

The figure in the above window has two buttons at the bottom left. The ‘Combos…’
button provides with possibilities to modify the design combos while the
‘Overwrites…’ button is used to overwrite some of the parameters used in the design
so that the information after re-design will be displayed.

5. Miscellaneous
In this part of the tutorial, procedures helping carry out analysis and design using some
unusual geometries will be covered.

5.1. Section Designer

The structural elements in a building may have shapes with unconventional geometries.
Even though ETABS provides with the facility to define sections with different pre-
defined shapes and geometries, architectural building designs may still possess unusual
geometries which are not included in the pre-defined ones. Fortunately, ETABS
provides with a means to create such unconventional frame sections and to provide a
reinforcement with any arrangement.

To see the how this is done in ETABS, we will assume an arbitrary unconventional
geometry and create it using ETABS. For this, we will define a reinforced concrete
column section with a regular octagon shape with each side’s dimension of 1.414m
73 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

(1414mm). There will be reinforcement bars at each corner and at the middle of each
side.
To do this using ETABS, click on ‘Define’ menu > ‘Frame Sections…’ and the
following ‘Define Frame Properties’ window will appear.

Figure 64
In the ‘Add I/Wide Flange’ drop-down menu, there is ‘Add SD Section’ option. This
option enables you to design frame sections with any shape and reinforcement
arrangement. When you click on it, the following ‘SD Section Data’ window will
appear.

Figure 65
In the above window, use the ‘Section name’ edit box to use the suggested default, or
specify another name for the section. The ‘Base Material’ drop-down list is used to
define the base material for the section. The selection made here determines the
74 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

availability of the options in the ‘Design Type’ and ‘Concrete Column


Check/Design’ boxes of the window. In the ‘Design Type’ drop-down list.
o If the ‘Base Material’ is ‘STEEL’ (or a steel material with another
name), the ‘No Design/Check’ option and the ‘General Steel
Section’ option are available.
• If the ‘No Design/Check’ option is selected, any frame
section assigned this property is not designed by any
postprocessor.
• If the ‘General Steel Section’ option is selected, any frame
section assigned this property is designed by the Steel Frame
Design postprocessor as a general section.
o If the ‘Base Material’ is ‘CONC’ (or any other concrete material
with another name), the ‘No Design/Check’ option and the
‘Concrete Column’ option are available.
• If the ‘No Design/Check’ option is selected, any frame
section assigned this property is not designed by any
postprocessor.
• If the ‘Concrete Column’ option is selected, any frame
section assigned this property is designed by the Concrete
Frame Design postprocessor.
o If the ‘Base Material’ is ‘OTHER’, only the ‘No Design/Check’
option is available. If the ‘No Design/Check’ option is selected,
any frame section assigned this property is not designed by any
postprocessor.
The radio buttons in the ‘Concrete Column Check/Design’ box are only active if
the ‘Concrete Column’ option has been selected in the ‘Design Type’ box. Use the
‘Reinforcement to be Checked’ option to specify that the concrete column is to have
its specified reinforcing checked when it is run through the Concrete Frame Design
postprocessor. The ‘Reinforcement to be Designed’ option is used to specify that
the concrete column is to have its new longitudinal reinforcing designed when it is run
through the Concrete Frame Design postprocessor. For the reinforced concrete
column section that we are going to create, the selections shown in Fig. 65 will be used.
After you have appropriately specified items in the rest of the form, click the ‘Section
Designer’ button in the ‘Define/Edit/Show Section’ box to go to the Section
Designer utility and draw the section.
The section designer is opened in a new window with its own menus, tool bars, status
bar and a drawing area. The drawing area consists of axes and grids. Before starting to
draw the section, the units of drawing should be set to a suitable unit. This is done by
using the drop-down menu in the right hand side of the status bar. Since we are going
to draw a section with a tolerance in millimeters, change the units to ‘KN-mm’. After
this, the grid spacing should be adjusted so that we can snap to the exact point when
75 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

we draw the section. This is done by modifying the preferences of the Section Designer
utility. The preference is adjusted by clicking on ‘Options’ menu > ‘Preferences’
command in the Section Designer utility. This results in the following ‘Preferences’
window.

Figure 66
In the above window, the ‘Background Guideline Spacing’ text field is used to
specify the spacing between the guidelines. It is very easy to snap to the intersection of
the guidelines. Thus, making the spacing between the guidelines be equal to the
dimension of the sides of the octagon will simplify the drawing of the horizontal and
vertical sides. Thus, enter 1414 in the first text field. We can also fine tune the snapping
by inserting as many fine grids as we want between the grid lines. The number of fine
grids to be used is specified in the ‘Fine Grids between Guidelines’ text field. For the
octagonal cross-section of 1414mm side dimension, we want to snap to points with
millimeters accuracy. Thus, the spacing between fine grids should be 1mm. Since the
distance between the guidelines is 1414mm, the spacing between the fine grids will be
1mm if there are 1413 fine grids between the guide lines. Thus, enter 1413 in the text
field corresponding to the number of fine grids. The rest values in the above window
have little significance in our drawing and we will use the default values. Clicking the
‘OK’ button will enforce the above preferences to be used during drawing.

To make the program snap to the fine grids, click on ‘Draw’ menu > ‘Snap to’ and
check the ‘Fine Grids’ option or just click on the equivalent button from the left
hand side tool bar.

76 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

To draw the octagon, click on ‘Draw’ menu > ‘Draw Poly Shape’ or click on the
equivalent button from the left hand side tool bar. This changes the cursor to a
vertical arrow and the section can now be drawn by left clicking at the corner points of
the octagon. Starting from the origin, the corner points of the octagon will have the
following corner points: (1414, 0) , (2414, 1000) , (2414, 2414), (1414, 3414), (0, 3414),
(-1000, 2414), (-1000, -1000). Thus, by using the xy coordinates in the status bar as
guide, left click at points having the above coordinates starting from the origin.
Zooming in and out might help to snap to the exact points. When you finish the
drawing by clicking on the last point, pressing the ‘Esc’ key will display the created
section on the drawing area. Right clicking anywhere inside the section will result in the
appearance of the ‘Shape properties- Polygon’ window as shown in the figure below.

Figure 67
The ‘Shape Properties- Polygon’ window provides with options to modify the
material, by using the ‘Material’ drop-down menu, and provide reinforcements, by
selecting ‘Yes’ from the ‘Reinforcing’ drop-down menu. When the ‘OK’ button is
clicked, the selections will be enforced on the section. After this, you will notice that
reinforcement bars being added to the section. The arrangement of the default
reinforcements from any side or corner can be modified by right clicking on the
reinforcement on the respective side or corner. To adjust the reinforcements on the
sides, right click on edge reinforcement from any side that you want to modify and the
following ‘Edge Reinforcement’ window will appear.

Figure 68
77 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)
AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

In this window, the reinforcement diameter can be selected by using the ‘Bar Size’
drop-down menu. The text fields corresponding to ‘Bar Spacing’ and ‘Bar Cover’ can
be used to control the spacing between bars and the concrete cover to the
reinforcement. The ‘Apply to All Edges’ checkbox is checked when it is desired to
apply the adjustments to all the edges. Using the values shown in Fig. 68 will add one
reinforcement at the center of each side. The bar size for the corner reinforcements can
also be adjusted by right clicking on them and selecting the reinforcement from the
available options.
When you exit the Section Designer utility by clicking the ‘DONE’ button at the right
hand side of the status bar, you return to the ‘SD Section Data’ window. Clicking ‘OK’
on this window will define a new section which can be added to the model along with
other possible conventional sections which were created as discussed in section 2.3 of
this tutorial.

5.2. Curved Beams

In recent versions of ETABS, curved beams can easily be modelled. However,


modelling of curved beams in older versions of ETABS is somewhat a cumbersome
task. There are two options to model curved beams in older versions of ETABS. The
first one is to create a fine cylindrical grid and to draw the curved beam as a
concatenated small segments. These segments shouldn’t be too short as compared to
their cross-sectional dimensions to avoid shear overstress error. This approach is
tedious and will not be discussed further in this tutorial.
The second option is to draw the curved beam using AutoCAD and to import it to
ETABS model. When you draw the curved beam in AutoCAD, make sure that the
coordinates of end points of the curved beam in AutoCAD and ETABS model should
coincide. Once you drew the curved beam in AutoCAD with the same end point
coordinates and dimensions, you have to same in DXF file format. To do this, click on
‘Save As…’ menu in the AutoCAD window and when you are prompted to save the
drawing, choose a suitable location and file name to access the file later. At the bottom
of the ‘Save Drawing As’ window, there is a ‘Files of type’ drop-down menu. From
this drop-down menu, select a file type with .dxf extension and click on the ‘Save’
button. This saves the file in DXF format which can be readily imported to ETABS.
To import the drawing to ETABS, click on ‘File’ menu > ‘Import’ > ‘DXF Floor
Plan…’ from the ETABS window. Then, you will be prompted to open the DXF file
from the location where you saved it. Sometimes you may also be prompted to save the
file again and do so whenever this happens. When you select the file and click on ‘Open’
button, the following ‘DXF Import’ window.

78 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)


AMBO UNIVERSITY CIVIL ENGINEERING DEPARTMENT 2016

Figure 69

In the above window, in the ‘Select Layers for Grids’ box, select the layer where you
drew the beam (and other structural members, if there are any) in the AutoCAD file
using the drop-down menus. The units used for the drawing the AutoCAD file should
be set from the units in ‘DXF File Units’ drop-down menu. The selection in the
‘Default Properties’ box can be made at this stage, if you already defined the frame
sections. If the section properties are not yet defined, you can adopt the default
selections and modify them at a later stage. The story where the curved beam will be
added will be selected from the ‘Story Level’ drop-down menu in the ‘Plan Location’
box. Note that, the options in the Similar To drop-down menu in the status bar of
ETABS can be adjusted to apply the importing of the curved beam to the intended
story. Clicking the ‘OK’ button, imports the curved beam at the intended location in
the ETABS model as a series of segments with a pin support between them.

Once the curved beam is added to the ETABS model, the segments should be made
continuous by modifying the support condition between them. To make the segments
continuous, any restraints between the segments should be removed. To do this, select
all the segments in the curved beam by rubber banding around the curved beam. Then
click on ‘Assign’ menu > ‘Joint/Point’> ‘Restraints (Supports)…’ and uncheck all
the boxes from the ‘Restraints in Global Directions’ box of the resulting window.
You can also assign the right frame section for the beam after the frame sections are
defined. In this manner, curved beams can be added to ETABS model.

79 BY: ASAYE CHEMEDA (E-mail: asayechemeda@yahoo.com)