You are on page 1of 1

I)"

Specimen ID : UT-N-OOl
ULTRASONIC TESTING Configuration : NODE
FLAWED SPECIMEN Dimensions : ¢lO"x21mm

PLAN VIEW

CROSSSECTION

Flaw Flaw Distance Max UT Indication


Flaw type
No Length Depth Height From 0 dB Angle
1 INCOMPLETE PENETRATION 27 18 3 50 +8 70
2. LACK OF FUSION 31 10 3 153 +8 60
3 SLAG INCLUSION 30 5 2 165 +2 70
4 LACK OF FUSION 27 - 4 335 - 00
5 LACK OF FUSION 28 4 3 565 +6 45
6 SLAG INCLUSION 27 12 2 760 +4 70
ALL DIMENTIONS IN MM

UT INSPECTOR
NAME 01)on((5- XUI\tf\J j'<{Uf'Kr(fcfli 6.1;. NAME

SIGNATURE SIGNATURE TRANQUOC DUNG


peN No. 300889
www.bindt.org/PCN
DATE DATE
r2-.~{'O-