You are on page 1of 1

© 2009 Heatec, Inc.

EQUIPMENT GROUND (PER NEC)


Publication No. 6-09-223

#8 AWG GREEN WIRE

480V / 3PH / 60HZ


L1 L2 L3
Short circuit current:
1 25kA rms symmetrical, 480V maximum 31

DISC1
WARNING
2 32
100 AMP MAIN
DISCONNECT
Risk of Fire or Electric Shock—The opening of the branch-circuit protective
device may be an indication that a fault current has been interrupted. All
3 current-carrying parts and other components protected by this device 33
should be examined and replaced if damaged. If burnout of a current
4 L1 L2 L3
DB1 element of an overload relay occurs, the complete overload relay must be 34
DISTRIBUTION LUGS
SIEMENS replaced.

5 35
T1 EMERGENCY
0.5 KVA SHUTDOWN
FUSE 1 FUSE 2 ESD PBLT6 H1 POWER ON TO CW1 120V
6 3A X1 7A 36
FNQ-R-3 H4 LT7 CONTROL WIRING
Jumper H2 FNQ-R-7
R W
7 H3 37
H1 H2 TO CW1 120V
3A X2
CONTROL WIRING
CONTROL
8 TRANSFORMER 38

MC 4-1
COMBUSTION AIR BLOWER
9 39
& FUEL OIL PUMP MOTOR
3RA1125-1BA23-1AK6 (1.4-2 AMPS)

10 40

1 MOT 4-1
11 HP COMBUSTION AIR BLOWER MOTOR 41
1 HP / 3450 RPM / 1.85 FLA

12 42

MC 1-1
13 MEDIA CIRCULATION PUMP 43
MOTOR STARTER CIRCUIT
3RA1125-1KA25-1AK6 (9-12.5 AMPS)

14 44

10 MOT 1-1
15 HP CIRCULATION PUMP MOTOR 45
10 H.P. / 3500 RPM / 11.7 FLA

16 46

MC 7-1
17 AUXILIARY MEDIA CIRCULATION PUMP 47
MOTOR STARTER CIRCUIT
3RA1125-1JA24-1AK6 (7-10 AMPS)
18 48

7.5 MOT 7-1


19 HP AUXILIARY HOT OIL PUMP MOTOR 49
7.5 H.P. / 3515 RPM / 8.66 FLA

20 50

MC 7-2
21 AUXILIARY MEDIA CIRCULATION PUMP 51
MOTOR STARTER CIRCUIT
3RA1125-1JA24-1AK6 (7-10 AMPS)

22 52

7.5 MOT 7-2


23 HP AUXILIARY HOT OIL PUMP MOTOR 53
7.5 H.P. / 3515 RPM / 8.66 FLA

24 54

MC 7-3
25 AUXILIARY MEDIA CIRCULATION PUMP 55
MOTOR STARTER CIRCUIT
3RA1125-1JA24-1AK6 (7-10 AMPS)

26 56

MOT 7-3
Based on Heatec Engineering Drawing 4001012

27 7.5 AUXILIARY HOT OIL PUMP MOTOR 57


Heatec HC and HCS Heaters

HP
7.5 H.P. / 3515 RPM / 8.66 FLA
Typical Wiring Diagram
Sheet 1 of 3 sheets

28 58

Ratings of all motor controllers shown


29 59
above are for Heatec HCS-100 and
HC-120 heaters only. Other heater
30 sizes use motor controllers with 60
different ratings. Only HC heaters have
motor controllers for auxiliary pumps.