Name of work ;-
8 Reiforcement:-
Long bottom bars 12 mm f 22 Nos.
2 :1 pier
350
600
2000 400
mm f
12
12 mm f 12 mm f 12 mm f
3 Nos. 12 Nos. 3 Nos.
pk_nandwana@yahoo.co.in Footing plan
Design of Rectangular Column Footing
1 Design constants.:-
For M 20 concrete, fe = 415 s st = 230 N/mm2
K = 0.286 J = 0.904 R= 0.914
2 Footing Size
W = 600 kN Let w' be equal to 10 % w= 60 kN
660 40 2
\ Base Area = = 5.50 m2 Let ratio of B to L = =
120 60 3
2
LxL = 5.50 or L = 2.9 m say = 3.00 m
3
2
B = x 2.9 = 1.9 m say = 2.00 m
3
However, provide a footing size = x 2.00
3.00 = 6.00 sqm
600
Net upward pressure po = = 100 kN/m2
3.00 2.00
3 Design of section :-
Bending moment M1, about section X-X is given by
poxB 100 x 2.00
M1 = (L-a)2 x10'6 = x( 3.00 - 0.60 )2x 10'6 N-mm
8 8.00
= 144000000 N-mm
Bending moment M2, about section X-X is given by
poxL 100 x 3.00
M2 = (B-a)2 x10'6 = x( 2.00 - 0.40 )2x 10'6 N-mm
8 8.00
= 96000000 N-mm Thus, M1 > M2
B.M. 144000000
\ d = = = 281 mm
Rc. B 0.914 x 2000
Keep d = 290 mm and the total depth 350 mm
Provide uniform thickness for entire footing.
The efffective depth found above has to be checked for shear
8 Reinforcement :-
shown in drawing
pk_nandwana@yahoo.co.in
Design of Rectangular Column Footing
Name of work ;- 0
600
pier
2 :1
350
Nos.
600
22
400
12 mm f
12 mm f 12 mm f 12 mm f
3 Nos. 12 Nos. 3 Nos.
64 64 64 64 64 64 64 64 64 64
150 or less
000)
M-50