You are on page 1of 2

One Powerful Vision

multi-modality
Accessories and Options Product Specifications YAG laser
Laser Source Q-switched Nd: YAG
Total Solution™ Tables
(standard accessory) Wavelength 1064 nm

Ellex Total Solution tables are



Energy 0.3 to 10 mJ, single pulse
designed to meet the needs continuously variable
of any environment. With the
Pulse Width 4 ns
added benefit of comfort,
flexibility and an optimized Burst Mode 1, 2 and 3 pulses per burst, selectable

patient-surgeon interface, the Spot Size 8 µm


Total Solution range of tables

Offset 0 to ± 500 µm, continuously variable
meets the alignment needs of (Anterior and Posterior)
even your most challenging
Illumination Coaxial (Ellex Reflex Technology)
patients.

Optimized for anterior • Wheelchair accessible,


Cone Angle 16 degrees

Repetition Rate up to 3 Hertz


and posterior YAG mobile
Aiming Beam red 635 nm, adjustable intensity
laser treatments. • Wheelchair accessible
Magnification 10x, 16x, 28x
• Mobile
Cooling air cooled
Whether you are performing anterior or
Electrical Requirements 100-240 VAC, 50/60 Hz, 500 VA
posterior capsulotomy with new generation
Weight 30kg, 66 lbs. (laser only)
IOLs, peripheral iridotomy for glaucoma or Indications for Use
Dimensions (HxWxD) 57 x 75 x 44 cm, 23 x 30 x 18 inches
YAG laser vitreolysis for the treatment of
Cataract Capsulotomy (laser only)
vitreous strands and opacities, Ultra Q™ with
Standard Accessories Total Solution™ tables, remote display,
Reflex Technology™ delivers higher accuracy Glaucoma Laser Iridotomy
safety glasses, laser safety sign, dust
and greater control. cover
Vitreous Posterior Membranectomy
(incl. Nd:YAG Laser Vitreolysis) Optional Accessories footswitch, five-position magnification
changer, beam splitter, co-observation
tube, 35 mm camera adapter, video
Diagnose and Treat with the Best camera adapter, tonometer mount,
capsulotomy, iridotomy and vitreolysis
Ellex is dedicated to advancing the role of ophthalmic laser lenses
technology through a line of premium laser and diagnostic
Specifications are subject to change without notice.
ultrasound systems. With more than 20,000 systems
installed worldwide, Ellex is known for its superior quality and
© 2013, Ellex Medical Pty Ltd. Ellex, Ultra Q, LASER CLASS 3B / IIIb Nd: YAG 1064nm, 55mJ Max, 4 ns pulse
LASER CLASS 2 / II Diode Laser: 635nm, <1mW Max CW

commitment to customer care. Reflex Technology, Total Solution are trademarks


VISIBLE & INVISIBLE LASER RADIATION –
AVOID DIRECT EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT per IEC 60825-1:2007, CLASS IIIb LASER PRODUCT per 21 CFR 1040 0805
of Ellex Medical Pty Ltd. E&OE. International
patents pending and/or granted. PB0023A.

Ultra Q™ with Reflex Technology™ achieves optical breakdown at

the industry’s lowest energy levels – allowing you to perform YAG


Headquarters USA Australia
82 Gilbert Street
Adelaide, SA, 5000 AUSTRALIA
7138 Shady Oak Road
Minneapolis, MN, 55344 USA
82 Gilbert Street
Adelaide, SA, 5000 AUSTRALIA
laser treatments in both the anterior and posterior segments with
+61 8 8104 5200 800 824 7444 +61 8 8104 5264

Japan Germany France a reduced risk of side effects.


4-3-7 Miyahara 4F, Yodogawa-ku Edisonstraße 20 La Chaufferie - 555 chemin du bois
Osaka 532-0003 JAPAN 63512 Hainburg GERMANY 69140 Rillieux la Pape FRANCE
+81 6 6396 2250 +49 6182 829 6900 +33 4 8291 0460
MULTI-MODALITY YAG LASER

1 Optimized Optics for Better Viewing 4 Pinpoint Precision

The quality and design of Ultra Q’s slit lamp optics are optimized for both anterior With a tolerance range Fine Two-Point Focusing System
and posterior YAG laser procedures. of ± 8 µm, Ultra Q’s fine,
two-point focusing system
Anterior Segment Viewing: Featuring Galilean converging optics with a 16° makes it easy for you to

4
stereoscopic angle, Ultra Q™ with Reflex Technology™ provides a more natural accurately position where
stereoscopic view combined with a small depth of field for precision focusing the optical breakdown will
on structures in the anterior segment. take place, irrespective of
Reflex Technology™ comprises whether you are working in
Ellex’s proprietary slit lamp 1 the anterior or the posterior
Coincident at focal plane

In Focus
Image at ± 8 µm

Out of Focus
illumination tower design, which Posterior Segment Viewing: the illumination tower, which can be used in a segment.
converges the operator’s vision, coaxial position, provides better depth perception in the posterior segment for
the target illumination and the precision focusing on structures in the vitreous cavity.
Fine Two-Point Focusing System
treatment beam onto the same
5 IOL-Friendly Photodisruption
optical path, and focuses them
onto the same optical plane –
offering optimized visualization
2 Efficient Energy Delivery for Safer Treatment
6 The newest generation IOLs, which are often implanted in younger patients and
those with low tolerance for visual error, may be more susceptible to pitting – posing
and illumination of the vitreous.
many challenges for anterior and posterior capsulotomy procedures. Featuring
This is of particular importance state-of-the-art YAG laser technology, Ultra Q™ with Reflex Technology™ is ideal for
when aiming at vitreous strands An Ultra Gaussian beam Ultra Gaussian Profile Fast Rise Time use with these IOLs. ConsistentlyCoincident
achieving optical
at focal plane breakdown atImage
ultra-low
at ± 8 µmenergy
or opacities, as it greatly profile and fast rise levels, it allows you to cut tissue muchInmore efficiently with fewer shots and with
Focus Out of Focus
minimizes the potential for time enable you to cut Conventional
optical less cumulative energy, thus reducing the risk of inadvertently marking the IOL.
breakdown
tissue more efficiently,
5
Conventional
focusing errors, and the risk of optical
using fewer shots and breakdown
damage to the natural lens or Ultra Q™
less cumulative energy optical
breakdown
Ultra Q™
the retina. optical
breakdown
– and with a reduced
6 Accurately Position Optical Breakdown
intensity

intensity
risk of side effects such
The unique illumination mirror
as retinal thickening or beam waist time
design, which briefly moves A continuously variable anterior and posterior offset control adjustment (from 0 to
an Profile Fast Rise Time collateral damage to
out of the laser pathway during ± 500 microns in both directions) provides optimum flexibility for all procedures.
n threshold
surrounding structures.
firing, ensures that the
optical breakdown laser
Ultra Q Technology
threshold
beam is never obstructed.
Ultra Gaussian Profile Fast Rise Time
optical
n threshold This minimizes the risk of
Conventional Laser
7
breakdown
threshold Designed to Maximize Your Workflow
under-dosing or over-dosing Conventional
optical
breakdown
the energy, ensuring that the 3 Better Performance Over the Long-Term Conventional
optical Ellex has integrated the laser and slit lamp for greater efficiency and reliability,
intensity

breakdown
desired therapeutic effect is Tango™ as well as for improved ease of use. The compact, efficient design of Ultra Q™

7
optical Tango™

8
achieved.
time
The solid-state Q-switch,
breakdown
Solid-State Q-Switch Lifespan
optical provides you with additional working space and convenient, simultaneous access
breakdown

which is made from to the patient and laser controls. The user-friendly, back-lit remote display allows
intensity

intensity

Comparative lifespan
In addition, the precision of of Ellex solid-state you to adjust treatment parameters in a dimly lit treatment room.
the industry’s finest
a two-point aiming system beam waist time Q-switch cavity and
components, is life- standard Q-switch
and the wide offset range tested to deliver over cavities.*

ensure accurate positioning 400,000 shots without Ellex Q-Switch


of the optical breakdown, thus any significant reduction 8 Faster Treatment
Standard Q-Switch
energy

preserving surrounding tissue in energy performance


from accidental damage. or beam quality. shots fired 425,000+
*Based on actual life testing. July 1999, Ellex.
2 3 With the industry’s fastest firing rate of up to 3 shots per second (3 Hz), Ultra Q™ with
Reflex Technology™ allows you to perform treatments quickly and efficiently.

You might also like