Fatima Design Review of Feed Impingement _
ae Plate of Vat tank of RVDF
Detailed Report of Design Review of Feed
Impingement Plate of Vat tank of RVD at NP plant
Prepared By Reviewed By ‘Approved By
| “TifarRasoot——} NasirAiaf | M-Aaghar Bilal
Project Sup, Project Engineer SA Project
eS 7
Projects Unit Pree Lolé
\ Materia 883217
Fatima sign novew of Feed Impingement Pat of
‘Vat tank of RVDF
Rowtory Dram fillers (RVDF) are installed at NP plant for separation of CN cake and
0s, 6-40-1122 A'B pumps are used to feed the CNTH solution to RVDF from
£6-40-2055/56. Vat tank feed nozzles have impingement plte inside the tank RVDF
cloth is damaged due to Impingement plate and resulting a shut down of plant
Impingement >
Plate Sm tk,
~e ore
~~ Vattank Sm thk, >
( Maerial=88321" —)
Problem statemen
Impingement pate damaged and hits the drum causing cus on cloth,
Below are the causes the Impingement plate damages.
1 Thickness loss
2 Welding detached
Evaluation:
Thickness of plate and tank are Smm and no Major thickness loss reported in tank
Material ofboth tank and plate ae SS-321 thats suitable fr this sevice
1. No thickness loss i observed on plate.
2 Welding filer i eported. Proper welding details snot availble on drawing.
‘Solution:-
1 Proper grove plus fillet welding tobe performed as per updated drawing.
{auschment-1) (Maint)
2‘Stifener plates tobe added ss per updated drawing (atachment-I) (Maint)
3. DPTofjainco be performed (Insp)