You are on page 1of 52

RELAZZO DECKING SYSTEMS

Installation guide.
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

RELAZZO decking systems- checklist for the installation

The checklist serves the purpose of providing help but does NOT replace the installation guide.

Base:

Gravel ballast Concrete slab Flat roof


Gradient min 10 mm/lfm Gradient min 10 mm/lfm Gradient min 10 mm/lfm
Concrete blocks possibly rubber spacers Substructure frame
WPC fixing bracket WPC fixing bracket Rubber spacers:
possibly rubber spacers possibly WPC joining plate WPC fixing bracket
possibly WPC joining plate possibly concrete blocks WPC joining plate
possibly adjustable foot possibly adjustable foot possibly concrete blocks
possibly adjustable foot adapter possibly adjustable foot adapter possibly adjustable foot
possibly adjustable foot screw possibly adjustable foot screw possibly adjustable foot adapter
Alu-UK 21x30 fixing system Alu-UK 21x30 fixing system possibly adjustable foot screw
Alu-UK 21x30 fixing system

Substructure:

90° installation 45° installation


Correct substructure clearance selected Correct substructure clearance selected

to the building min.10mm to the building min.10mm


for board joints 60 to 100 mm for board joints 60 to 100 mm

Boards:

Brushing direction (print/identification groove) to a fixed building component min.20mm for joint 3 mm/lfm
to a fixed building component min. 10 mm Adhesive
if board < 2lfm

REHAU bracket system:

End bracket
Flush end clips
Centre bracket
Quick installation clip
Flex clip

Finishing:

End cap Aluminium end trim Flexible end trim


Adhesive Adhesive Adhesive
Fixing set

Please note that any warranty claims are void if the installation guide is not complied with and other component than RELAZZO system
components are used. Sketches and pictures are only provided for illustration purposes.

2
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

CONTENTS

1 Product range 4

2 Important information 8

3 General RELAZZO installation and assembly 11


3.1 Subsoil 11
3.2 Levelling 13
3.3 Substructure 15
3.4 Boards 19

4 RELAZZO puro 22
4.1 WPC substructure 22
4.2 Custom installations 27
4.3 Accessories 31

5 RELAZZO finello, naturo, coro, calmo 35


5.1 WPC substructure 35
5.2 Aluminium substructure 38
5.3 Custom installations 43
5.4 Accessories 48

3
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

1 PRODUCT RANGE

General base

Adjusting foot 30-50 mm Adjusting foot 50-90 mm Adapter for adjusting foot 50-90 mm: Rubber spacer 3, 5, 10 mm

40 mm
30 mm
60 mm
50 mm
60 mm

50 mm
30 mm
40 mm

1.7 kg/lfm 1.3 kg/lfm
1.7 kg/lfm 1.3 kg/lfm

WPC substructure 60 x 40 WPC substructure 60 x 40 WPC substructure 50 x 30 WPC substructure 50 x 30

WPC fixing bracket (V4A stainless steel) WPC joining plate (V4A stainless steel) Aluminium adjustable foot screw WPC adjustable foot screw

4
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

General accessories

60 mm

40 mm

Adhesive Aluminium trim 60x40 Joint cover LED spotlight set / LED spotlight
extension set

RELAZZO puro solid, coro

Edge fixing strip Edge fixing angle

RELAZZO puro (30 mm)

1.9 kg/lfm 2.6 kg/lfm 4,4 kg/lfm

RELAZZO puro 30 x 140 board RELAZZO puro 30 x 194 board RELAZZO puro solid 30 x 140 board

End cap 30 x 140 End cap 30 x 194

Flush end bracket 30 WPC End bracket 30 WPC Centre bracket 30 WPC

5
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Aluminium step profile 30 WPC Joint filler profile 30 RELAZZO flex trim 30

RELAZZO naturo, finello, coro, calmo (23 mm)

2.3 kg/lfm 3.6 kg/lfm

0.62 kg/lfm

RELAZZO naturo/finello 23 x 169 board RELAZZO coro, calmo 23 x 140 board Aluminium substructure 21 x 30

RELAZZO fixing set 21 x 30 Quick installation clip 23 aluminium Flex clip 23 aluminium

End bracket 23 WPC End bracket 23 aluminium Flush end bracket 23 WPC

Centre bracket 23 WPC Centre bracket 23 aluminium End cap 23 x 169

6
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Aluminium step profile 23 WPC Aluminium step profile 23 aluminium Flex trim 23

Tool list

Protective goggles Spirit level Measuring tape Chop saw Side cutter

Drill Wood drill bit 2.0 mm Metal drill bit Router Hole saw Rubber mallet
3.5 mm, 4 mm

7
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

2 IMPORTANT INFORMATION

Explanation of the icons:

permitted, correct application NOT permitted, incorrect application Attention:

Do not screw together directly


RELAZZO boards must not be screwed directly..

Bear the installation direction in mind


Ensure an even installation of the boards in brushing direction (arrow
printed on board). In addition to this, pips can be seen inside cavities
on hollow profiles and on the side of solid profiles to indicate the
profile orientation.

8
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Gradient
A gradient of min. 1 % (10 mm/lfm) is to be adhered to in order to
min. 10 mm/lfm prevent water spots and waterlogging. In addition to this, the gradient
also helps remove dirt naturally with rain and maintains the high slip
resistance of RELAZZO boards thanks to this.

Adhere to torque
Use a low torque setting so as not to over-tighten screws when
~ 1.1 Nm screwing them in.

Cut
A 90° cut on the board ends is recommended for an optimum joint
pattern
.

9
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Bear expansion joints in mind


WPC decking boards are subject to natural expansion.
A sufficient expansion joint therefore has to be planned in between each board as well as the substructure.

Ventilation and ventilation at rear


In order to ensure quick drying of the materials underneath the boards as well as the board underside, it is mandatory to observe specified
minimum clearances
. Waterlogging is to be prevented.
When using jointing profiles, the clearance between the subsoil and the board underside is to be increased to a minimum of 10 cm. In
particular in this case, it is essential that the minimum clearances to fixed building components are maintained or increased in order to ensure
sufficient ventilation and ventilation at rear. The clearance between the subsoil and the board must not be backfilled.

Documentation of the installation


It is recommended to photograph the decking during installation of the substructure and immediately following its completion and to document
the pictures as part of the acceptance record for subsequent modifications, for documentation of the ground design and the installation
clearances as well as in general as evidence that this installation guide has been adhered to.

No use for self-supporting, structural purposes


The WPC profile RELAZZO and the substructure have been specially developed for the use as decking surfaces. The products do not have
building authority approval and for this reason are not to be used for self-supporting, structural purposes. The local building regulations are to
be observed accordingly.

Colour development
The raw material wood also accounts for possible colour variations and tinges that enhance the natural wood appearance. When
processing different batches, it is recommended to mix up the batches, so that this natural effect is used to its full potential.

Safety warnings
The information and recommendations given here do not release the fabricator from strict adherence to all applicable safety and environmental
regulations as well as the regulations of the Labour Inspectorate and employer's liability insurance association, as these always take prece-
dence. It is essential to observe and adhere to the safety warnings of the adhesives used. Additional work equipment, e.g. alcohol-based
cleaners and other highly flammable materials must only be kept in a safe and well-ventilated location. Always use safety equipment such as
gloves, safety goggles, ear protection and dust masks.

10
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

3 GENERAL RELAZZO INSTALLATION AND ASSEMBLY

General installation

3.1 Subsoil
3.2 Levelling
3.3 Substructure
3.4 Board

3.1 Subsoil

Installation on the ground NOT allowed

Load-bearing building components floor construction


RELAZZO style has no approval for self-supporting, structural purposes. In the case of installation on balconies or jetties for example, it is
important to provide a structurally sound foundation (e.g. steel mesh) after the approval of a structural engineer by observing the local building
regulations.

Lawn/soil floor construction


An installation on the soil or lawn is not permissible without a frost-resistant or water and erosion-resistant design of the subsoil and installation
by a specialist company due to ground settlements.

11
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Sand floor construction


An installation on sand is not permissible without a frost-resistant or water and erosion-resistant design of the subsoil and installation by a
specialist company due to ground settlements.

Floor construction allowed

Frost-resistant stone filling floor construction


The local building regulations for the design of a frost-resistant stone filling in accordance with standards are to be complied with.
The specialist department of your choice is responsible for the design.
REHAU cannot provide a warranty for the design of the stone filling.

Concrete floor construction


The local building regulations for the design of the frost-resistant concrete slab in accordance with standards are to be complied with.
The specialist department of your choice is responsible for the design.
REHAU cannot provide a warranty for the design of the concrete slab.

12
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Flat roof floor construction


The local building regulations for the design of a flat roof in accordance with standards are to be complied with. The specialist department of
your choice is responsible for the design. REHAU cannot provide a warranty for the design of the flat roof. It is to be ensured that the subsoil
(e.g. insulation) cannot yield as a result of the loads acting upon it.

3.2 Levelling

a. Rubber spacer
Rubber spacers may be used for levelling and raising the substructure
Rubber spacers 50 x 50 x 3, 5, 10 mm
(to prevent water logging). The rubber spacers also serve the purpose
of reducing noises (impact sound). Rubber spacers must not be
stacked.

b. Concrete spacers
Concrete spacers may be used for levelling and raising the substruc-
ture (to prevent water logging).

13
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. Adjustable foot

- The height is adjusted with millimetre precision by rotating the six


protruding, rotating fingers of the height-adjustment wheel.
- The installation is carried out by placing the substructure onto the
adjusting foot and lateral fastening with a screw.
- Adjusting foot 30-50 mm: 30 – 50 mm height-adjustable
- Adjusting foot 50-90 mm: 50 – 90 mm height-adjustable
- Adjusting foot adapter for adjusting foot 50-90 mm: 35 mm
- Floor space: Ø 215 mm.
- Max. Max. permissible useful load per adjusting foot: 6 kN

Adjusting foot 50-90 mm Adjustable foot adapter Adjusting range (mm)

from to
1 + 1 85 125
1 + 2 120 160
1 + 3 155 195
1 + 4 190 230
1 + 5 225 265
1 + 6 260 300
1 + 7 295 335
1 + 8 330 370
1 + 9 365 405
1 + 10 400 440
1 + 11 435 475
1 + 12 470 510
max. permissible total height: 500 mm

WPC substructure Aluminium substructure

< 300 mm < 300 mm < 400 mm < 400 mm

Adjustable foot with screw for WPC substructure Adjustable foot with screw for aluminium substructure

14
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

3.3 Substructure

a. Installation on various bases

Installation on frost-resistant stone filling


The substructure profiles must not be installed directly onto the subsoil. The substructures are to be fixed onto concrete spacers with fixing
bracket, fastening system aluminium substructure or onto the adjusting feet with screws.

Installation on concrete
The substructures located at the edge of the surface are to be fixed onto concrete base with a fixing bracket, fastening system aluminium
substructure or onto the adjusting feet with screws. Uneven ground is to be levelled using rubber spacers.
If the substructure profiles are installed on sloping ground, rubber spacers, slabs (blocks, paving stones) or adjustable feet are to be
used to prevent water logging.

Installation on a flat roof


A frame is to be built using the substructure. This frame is to be raised off the drainage membrane using rubber spacers or adjustable feet. It is
forbidden to screw the substructure down.
Weights/fastenings to prevent movement under wind loads must be confirmed by a specialist.
Any damage to the flat roof membrane is to be ruled out!
The compatibility of the rubber spacers and adjustable feet with roofing felt is to be checked.

15
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

b. Requirement table Subsoil- substructure

= required Gravel ballast Concrete slab Flat roof


= optional
= not permitted
Concrete spacers
Rubber spacer for drainage/water outlet

Rubber spacer for levelling


Assembly system for fixing to the subsoil
Assembly system for frame construction
Joining plate for substructure extension

Adjustable feet

16
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. General installation dimensions of the RELAZZO substructures

min. 10 mm min. 10 mm

max. 400 mm
max. 300 mm

min. 10 mm min. 10 mm

min. 10 mm
min. 10 mm

Expansion joint Expansion joint

Expansion joint

Width max. 14 m Width max. 14 m


A A

Expansion joint (mm) = width (m) x 1.5 If the width (substructure length) exceeds 14 m, an expansion joint is
to be created between the substructures and the boards (joint width
= min. 10 mm (mm) = min 2 x ).

17
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

d. Fastening points on the subsoil / frame construction

Fastening to the subsoil Frame construction

Fastening the substructure to the edge of the surface and in the surface for continuous board joints.

Fastening the substructure to the edge of the surface and in the surface for continuous board joints.

18
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

3.4 Boards

The expansion joints are to be calculated according to the longest Board length Expansion joint
used profile length: 4 lfm ≥ 12 mm
5 lfm ≥ 15 mm
3 mm / lfm (in tropical or sub-tropical / humid-warm climate ≥
6 lfm  ≥ 18 mm
4 mm / lfm)
Tip: Choose profile lengths of ≤ 3 m for two or more joints in a row.

min. 10 mm

30 – 50 mm (5 mm for aluminium end trim )


min.20 mm (min. 10 mm if board ≤ 2lfm)

min. 20 mm 3 mm / lfm 3 mm / lfm 1.5 mm / lfm

To fixed building components min.20 mm (min. 10 mm if board ≤ 2lfm)


Special case (longitudinal/diagonal boards): 1.5 mm/lfm)

19
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Installation types - substructure layout (WPC and aluminium)

Brick pattern

45°

The load-bearing distance for the board must be reduced by 25 % if installed diagonally.

Joint

20
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Mitre

21
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

4 RELAZZO PURO

4.1 WPC substructure

min. 10 mm

max. 500 mm

max. 300 mm

a. Fixing the substructure (to the edge of the surface)

max. 100 mm max. 100 mm


max. 1000 mm

22
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

b. Use of brackets

End bracket

min. 10 mm

4.2 x 25

Centre bracket

~ 1.1 Nm

4.2 x 25

Flush end brackets

0 mm

4.2 x 25

max. 500 mm

max. 50 mm

min. 10 mm

23
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. Board assembly

It is to be ensured during the installation that the screws are only


5 mm screwed in half way so that the bracket remains loose in order to
insert the subsequent boards like this.
The screws are subsequently fully tightened.

24
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

d. Dismantling and reassembling

5 mm

25
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

26
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

4.2 Custom installations

The local building regulations for the design of a step geometry in accordance with standards are to be complied with.
a. Step installation with WPC substructure

max. 500 mm
min. 150 mm

33-35 mm

1. Substructure design 2. Fastening the first bracket

3. Riser installation 4. Step profile fastening

It is permitted to cut the hollow section board in longitudinal direction (max.board length 80 cm) if a step profile is used.

Pre-cut part
Length

5. Calculating the step 6. RELAZZO board pre-cuts


Length = first bracket to the spacer block of the aluminium step profile Pre-cut part = length - 147 mm per board

7. Calculating the step 8. View of the step design

27
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

b. Step installation with edge fixing angle and RELAZZO puro solid
The provided countersunk head screws must be used for installing the edge fixing angle.

Pre-cut part
min. 40 mm

max. 500 mm

Pre-cut part
Height
min. 3 screws

1. Pre-cut part calculation: Pre-cut part = (height/ 2) - 4 mm 2. Fastening RELAZZO puro solid edge fixing angle

Pre-cut part
min. 40 mm
Width

Pre-cut part

min. 2 screws

3. Attaching the edge fixing angle to the substructure 4. Pre-cut part calculation: Pre-cut part = (width/ 2) - 4 mm
Height for pre-cut part

min. 3 screws per board

min. 2 screws

5. Fastening RELAZZO puro solid with edge fixing angle 6. Attaching the edge fixing angle to the substructure and screwing down the centre
bracket

min. 2 screws

min. 3 screws per board

7. Fastening RELAZZO puro solid with edge fixing angle 8. Attaching the edge fixing angle to the substructure and screwing down the centre
bracket

28
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. Edging with edge fixing strip


The provided countersunk head screws must be used for installing the edge fixing strip.

min. 40 mm

min. 2 screws

min. 3 screws

1. Fastening with RELAZZO edge fixing strip 2. Attaching the edge fixing strip to the substructure

max. 500 mm

3. Screwing the centre bracket onto the next RELAZZO board.

d. Edging with edge fixing angle


The provided countersunk head screws must be used for installing the edge fixing angle.

Pre-cut part
min. 70 mm
min. 2 screws
min. 40 mm

min. 3 screws per board

1. Fastening with RELAZZO edge fixing strip 2. Attaching the edge fixing angle to the substructure

max. 500 mm

3. Screwing the centre bracket onto the next RELAZZO board.

29
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

e. Pool border

20 mm Board length max. 2 m 10 mm

20 mm

30
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

4.3 Accessories

a. Aluminium end trim

A fixing set is sufficient for approx. 8 m aluminium end trim (15 mm spacers)

5 mm

ø 4 mm
ø 2 mm

min. 15 mm
min. 15 mm
4.0 x 30

max. 500 mm min. 5 mm

min. 5 mm

31
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

b. Assembly of jointing profiles

Joint filler profile Joint cover

The joint cover should be cut to length free from tension prior to installation.

When using jointing profiles, the clearance between the subsoil and the lower board edge is to be increased to a minimum of 100 mm.
In particular in this case, it is essential that the minimum clearances to fixed building components are maintained or increased in order
to ensure sufficient ventilation and ventilation at rear. The clearance between the subsoil and the board must not be backfilled.

c. End cap

It is to be ensured that the ventilation/drainage slits of the end caps maintain their function and are not sealed by adhesive.

32
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

d. Flexible end trim

2 mm

2 mm

10-12 mm

min.17 mm

min.16 mm

33
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

e. LED spotlight installation


ø 68 mm
approx. 2000 mm

3 mm
40 mm approx. 6000 mm

approx. 200 mm
approx. 3000 mm 20 mm

ø 44 - 46 mm

½ max. 60 mm

LED spotlight set


- Do not screw the transformer onto the board
- Install cable loosely (not under tension).

220-240 V
47-63 Hz

This connection must be established by an electrical specialist.

LED spotlight extension set

max. 6 x LED spotlights

34
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

5 RELAZZO FINELLO, NATURO, CORO, CALMO

5.1 WPC substructure

min. 10 mm

max. 420 mm

max. 300 mm

a. Fixing the substructure (to the edge of the surface)

max. 100 mm max. 100 mm


max. 1000 mm

35
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

b. Use of brackets

WPC substructure
End bracket

min. 10 mm

4.2 x 25

Flush end bracket

4.2 x 25

max. 500 mm

max. 50 mm

min. 10 mm

Centre bracket

~1,1 Nm

4.2 x 25

36
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. Board installation with WPC substructure and V4A bracket system

It is to be ensured during the installation that the screws are only screwed in half way so that the
bracket remains loose in order to insert the subsequent boards like this.
The screws are subsequently fully tightened.

37
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

5.2 Aluminium substructure

min. 10 mm

max. 420 mm

max. 400 mm

a. Fixing the substructure (to the edge of the surface) and construction of a frame

max. 100 mm

max. 1000 mm

38
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

b. Use of brackets

End bracket

min. 10 mm

ø 3.5 mm

3 mm 3 mm

4.0 x 22 Drill hole area

3 mm
3 mm

Quick installation clip

The quick installation clip has to be installed alternately into each side of the aluminium substructure.
A fixing pin per board has to be pressed into the quick installation clip for a quick installation clip .
A fixing pin is cast onto each fourth quick installation clip and must be broken off in order to be able to use it.

39
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

Centre bracket

max. 2 m max. 2 m

4.0 x 22

A steel centre bracket must be screwed on every max. 2 m board width in every aluminium substructure.

Flex clip

4.0 x 22

If the board is not installed at a right angle to the aluminium substructure (e.g. mitre) a flex clip must be used.

40
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. Board installation with aluminium substructure and quick installation bracket

41
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

d. Dismantling and reassembling

ø 3.5 mm

42
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

5.3 Custom installations

a. Step installation with WPC substructure


The local building regulations for the design of a step geometry in accordance with standards are to be complied with.

1. Installation of the substructure and end bracket 2. Fastening the aluminium step profile

3. Installation of the substructure and steps 4. Offset installation substructure

min. 15 mm

5. Step installation 6. Riser installation

43
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

b. Step installation with WPC substructure


The local building regulations for the design of a step geometry in accordance with standards are to be complied with.

max. 420 mm

1. Substructure design 2. Fastening the first bracket

3. Riser installation 4. Step profile fastening

Pre-cut part

5. Steps 6. RELAZZO board pre-cuts

7. Steps 8. View of the step design

44
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. Step installation with a edge fixing angle


The provided countersunk head screws must be used for installing the edge fixing angle.

Pre-cut part
min. 40 mm

max. 420 mm

Pre-cut part
min. 3 screws

Height

1. Pre-cut part calculation: Pre-cut part = (height/ 2) - 4 mm 2. Fastening RELAZZO coro with edge fixing angle

Pre-cut part
Width min. 40 mm

Pre-cut part

min. 2 screws

3. Attaching the edge fixing angle to the substructure 4. Pre-cut part calculation: Pre-cut part = (width/ 2) - 4 mm
Height for pre-cut part

min. 3 screws per board


min. 2 screws

5. Fastening RELAZZO coro with edge fixing angle 6. Attaching the edge fixing angle to the substructure and screwing down the centre
bracket

min. 2 screws

min. 3 screws per board

7. Fastening RELAZZO coro with edge fixing angle 8. Attaching the edge fixing angle to the substructure and screwing down the centre
bracket

45
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

d. Edge fixing strip


The provided countersunk head screws must be used for installing the edge fixing angle.

min. 40 mm

min. 2 screws

min. 3 screws

1. Fastening with RELAZZO edge fixing strip 2. Attaching the edge fixing strip to the substructure

max. 420 mm

3. Screwing the centre bracket onto the next RELAZZO board.

e. Edge fixing angle

The provided countersunk head screws must be used for installing the edge fixing angle.

min. 70 mm Pre-cut part


min. 2 screws
min. 40 mm

min. 3 screws per board

1. Fastening with RELAZZO edge fixing strip 2. Attaching the edge fixing angle to the substructure

max. 420 mm

3. Screwing the centre bracket onto the next RELAZZO board.

46
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

f. Pool border

20 mm Board length max. 2 m 10 mm

20 mm

47
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

5.4 Accessories

a. Aluminium end trim

A fixing set is sufficient for approx. 8 m aluminium end trim (15 mm spacers)

5 mm

ø 4 mm
ø 3.5 mm
4.0 x 30

min. 15 mm

max. 500 mm
min. 15 mm

b. End cap

It is to be ensured that the ventilation/drainage slits of the end caps maintain their function and are not sealed by adhesive.

48
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

c. Flexible end trim

2 mm

2 mm

10-12 mm

min.12 mm

min.12 mm

d. Installation of the joint cover


Joint cover (only possible in combination with stainless steel brackets)

The joint cover should be cut to length free from tension prior to installation.

When using the joint cover, the clearance between the subsoil and the bottom edge of the board is to be increased by min. 100 mm.
In particular in this case, it is essential that the minimum clearances to fixed building components are maintained or increased in order
to ensure sufficient ventilation and ventilation at rear. The clearance between the subsoil and the board must not be backfilled.

49
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

e. LED spotlight installation

ø 68 mm
approx. 2000 mm

3 mm
40 mm approx. 6000 mm

approx. 200 mm

approx. 3000 mm 20 mm

ø 44 - 46 mm
½

½
max. 60 mm

LED spotlight set


- Do not screw the transformer onto the board.
- Install cable loosely (not under tension).

220-240 V
47-63 Hz

This connection must be established by an electrical specialist.

LED spotlight extension set

max. 6 x LED spotlights

50
REL A ZZO DECKING SYSTEMS INSTALL ATION INSTRUCTIONS

51
Do you require more information, samples or advice?

Please contact your local specialist retailer. You can find a local distributor and further information about the RELAZZO product range as well
as the up-to-date installation guide and technical information on our homepage
www.rehau.com/relazzo.
You are also welcome to contact us by e-mail at relazzo@rehau.com.

Legal information: The WPC profile RELAZZO and the substructure do not have general technical approval and for this reason are not to be
used for self-supporting, structural purposes. The local building regulations are to be observed accordingly.

Please observe the current technical information.

Subject to technical modifications..

Our verbal and written application engineering advice is based upon experience and the best of
our knowledge. However, it is to be regarded as non-binding information. Working conditions © REHAU AG + Co
over which we have no influence and applications other than those specified exclude any claim Rheniumhaus
resulting from our information. We recommend to check as to whether the REHAU product is
95111 Rehau
suitable for the envisaged purpose. Application, use and processing of the products is carried
out beyond the scope of our control and are therefore exclusively in your area of responsibility.
The document is protected by copyright. The rights conferred therein, in particular those In the event that a liability is nevertheless considered, then this will be based exclusively on
relating to translation, reprinting, extraction of pictures, electronic transmissions, reproduction our Conditions of sale, which can be found at www.rehau.de/LZB. This also applies to any
by photo-mechanical or similar means and storage on data processing equipment, remain warranty claims, whereby the warranty applies to the consistent quality of our products in
reserved. accordance with our specification. R20604 EN 01.2016

You might also like