You are on page 1of 25

Extension of A1 Building For IITB Within IIT-B Campus Powai, Mumbai-400 076

SUMMARY
SR.
ITEM DESCRIPTION AMOUNT RS.
NO.

I Dismantling and Demolition -

II SUB STRUCTURE WORKS -

III SUPER STRUCTURE WORK -

IV ELECTRICAL WORK

TOTAL OF (I+II+III)……..
Extension of A1 Building For IIT-B Within IIT-B Campus Powai, Mumbai-400 076

SUMMARY : ITEM-WISE
SR.
ITEM DESCRIPTION AMOUNT RS.
NO.

I Dismantling and Demolition


TOTAL OF Dismantling and Demolition

II SUB STRUCTURE WORKS


A Excavation & Earth Works
B Plain Cement Concrete & Plum concrete
C Reinforced Cement Concrete
D BLOCK MASONRY WORK

TOTAL OF SUB STRUCTURE WORKS

III SUPER STRUCTURE STRUCTURAL WORK


A CONCRETE WORK
B SUPER STRUCTURE GENERAL FINISHINGS WORK
& BLOCK MASONARY WORK
C PLASTERING
D PAINTING
E FLOORING & DADO
F DOORS & WINDOW
G STEEL WORK
H WATER PROOFING

TOTAL OF SUPER STRUCTURE STRUCTURAL


WORK

TOTAL OF (I+II+III)……..
BILL OF QUANTITIES

Extensiion of A1 Building For IIT-B Within IIT-B Campus Powai, Mumbai-400 076

Rate Reference:CPWD DSR-2013


SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)

I Dismantling and Demolition


1 Item No- Dismantling tile work in floors and roofs laid in cement mortar 64.16 Smt
15.23.1 / Pg- including stacking material within 50 metres lead For thickness
250 of tiles 10 mm to 25 mm

2 Item No- Demolishing brick work in cement mortar/ Water proofing 20.77 Cum
15.7.3 / Pg- manually/ by mechanical means including stacking of
248 serviceable material and stacking of unserviceable material
within 50 metres lead as per direction of Engineer - in- charge
and then disposing the same out of the campus as per local
municipal rules..

3 Item No-15.3 Demolishing R.C.C. work manually/ by mechanical means 2.76 Cum
/ Pg-248 including
stacking of steel bars,Stacking the servicable materials and
stacking of unserviceable material within 50 metres lead as per
direction of Engineer - in- charge and then disposing the same
out of the campus as per local municipal rules..

4 RA pg 115 Dismatling aluminium /gypsum partitions ,doors ,windows,fixed 10.89 Sqm


glazing and false ceiling inclusding disposal of unserviceable
surplus maetrial outside institute premises as per local
municipal corporation byelaws and stacking of serviceable
material as directed by engineer

Total of Dismantling and Demolition

II SUB STRUCTURE WORKS

Note : - All the items of substructure include the cost of


dewatering, wherever necessary during the progress of
work till its completion without any extra cost to IITB.
Tenderers are advised to visit site of work to acquaint
themselves about the level of subsoil water, drainage
facility for dewatering, accessibility to the site & quote the
rates accordingly.

A Excavation & Earth Works

Page 3
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
Earth work excavation by mechanical means / labour
means for foundation pits, trenches etc. in all types of
soils other than soft and hard rock up to depths mentioned
below including shoring dressing the sides, trimming,
ramming and preparing the bed for foundation & refilling
around the foundation and in plinth with selected
excavated earth / Demolished structure debris, in layers
not exceeding 150 mm thick, watering, compaction to 95%
proctor density and disposing of the surplus earth within a
distance of 50 metres etc.complete as per specifications,
drawings & as directed by the EIC.

5 Item No-2.8 / a) Depth not exceeding 1.50 m. from ground level. 137.63 Cum
Pg-72

Page 4
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
6 Item No-2.11 b) Depth exceeding 1.5m & up to 3m from ground level 80.19 Cum
/ Pg-73

7 Item No-2.12 c) Depth exceeding 3.0 m & up to 4.5m from ground level 0.00 Cum
/ Pg-73

Earth work excavation by mechanical means /labour


means for foundation pits, trenches etc. in soft rock up to
depths mentioned below including shoring, dressing the
sides, trimming, ramming and preparing the bed for
foundation & refilling around the foundation and in plinth
with selected excavated materials / Demolished structure
debris, in layers not exceeding 150mm thick,
watering,compaction to 95% proctor density ,
consolidation & disposing of the surplus excavated
materials, within a distance of 50 metres etc.complete as
per specifications, drawings and as directed by the
Engineer-in-charge.

8 Item No- a) Depth not exceeding 1.50 m. from ground level. 0.00 Cum
2.9.1 / Pg-73

9 Item No-2.11 b) Depth exceeding 1.5m & up to 3m from ground level 24.06 Cum
/ Pg-73

10 Item No-2.12 c) Depth exceeding 3.0 m & up to 4.5m from ground level 0.00 Cum
/ Pg-73

Earth work excavation by mechanical means /labour


means for foundation trenches etc. in hard rock including
Concrete structure if any. by chiseling up to depths
mentioned below including ,trimming, dressing the sides
and bed to the required size of foundation , and preparing
the bed for foundation and refilling around the foundation
and in plinth with selected excavated materials /
Demolished structure debris in layers not exceeding
150mm thick, watering ,compaction to 95% proctor density,
consolidation and stacking or disposing of excavated
materials within a distance of 50 metres etc. complete as
per specifications ,drawings & as directed by the Engineer-
in Charge..

11 Item No- a) Depth not exceeding 1.50 m. from ground level. 2.19 Cum
2.9.3/ Pg-73

12 Item No-2.11 b) Depth exceeding 1.5m & up to 3m from ground level 2.19 Cum
/ Pg-73

13 Item No-2.12 c) Depth exceeding 3.0 m & up to 4.5m from ground level 0.00 Cum
/ Pg-73

14 Item No-2.25 Filling in plinth with murrum/ selected earth approved 235.41 Cum
/ Pg-74 by Engineer-in-charge excavated from nearby borrow
areas including all leads up to 2 Km, lifts, loading,
unloading, stacking, leveling, spreading, in layers not
exceeding 150 mm thick, watering, compaction to give 95%
proctor density etc. complete as per specifications,
drawings & as directed by the EIC.

Page 5
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)

15 Bd/A-12 P- Providing and laying dry rubble stone hard core soling of 42.16 Cum
264 (PWD) 230mm thickness consolidated thickness in sub base to
floor and in plinth protection to required levels and lines
with first quality rubble, hand set, well packed including
filling the interstices with smaller stone chips, supplying &
finishing/blinding the surfaces with approved blinding
quality murrum including watering, consolidation etc.
complete as per specifications, drawings & as directed by
EIC.

16 Disposing off the surplus excavated materials by


mechanical transport lead up to 2 KM to the nearby
dumping pits/ dumping areas with in IITB campus
identified by Engineer in charge , including all lifts,
loading, unloading, stacking etc. complete as per
specifications & as directed by the EIC.

17 Item No- a) all type of Soil 182.25 Cum


1.1.2 / Pg-62

18 Item No- b) Soft rock & Hard rock 26.24 Cum


1.1.4 / Pg-62

1. Voids @ 20% for all type of soils and for Soft rock and
Hard rock 50% shall be deducted from stack/truck
measurements to arrive at the net quantity for payment
incase direct measurements is not possible.
2. Approval from concerned authorities is the
responsibility of contractor & quoted rate shall be
inclusive of all charges if any from the statutory authorities
such as royalty etc.

TOTAL :

B Plain Cement Concrete & Plum concrete


19 Item No- Providing and laying in position cement concrete of specified 5.98 Cum
4.1.8 / Pg- grade excluding the cost of centering and shuttering - All work
85 up to plinth level : For 1:4:8 (1 Cement : 4 coarse sand : 8
graded stone aggregate 40 mm nominal size)

C Reinforced Cement Concrete

Page 6
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
a) All RCC shall be as specified and shall be carried out strictly
in accordance with the drawings and specifications.
b) The rates for RCC works shall be inclusive of all depths
below G.L slabs at all heights as detailed in the drg but
exclusive of cost of reinforcement unless otherwise mentioned.
c) All coarse aggregate to be 20 mm maximum size and
uniformly graded unless otherwise mentioned.
d) For all RCC items, the rates quoted shall include the
following without any extra cost to the Dept.
i) Spacers to maintain clear cover for reinforcement.
ii) Fixing at correct level & in proper alignment the inserts,
pipe sleeves, pipe bends, fan hooks, other pipe specials etc.
supplied by Department or Contractor unless otherwise
mentioned in a separate item
iii) Test for concrete shall be done as per IS 456-2000 and the
cost of the testing to be carried out shall be borne by the
contractor.
d) Precaution to be taken to avoid uplifting forces on the raft of
water tanks.
As per the soil report, water table is expected near the ground
level and contractor is advised to use following sequence
during concreting of the water tank.
1) Dewatering to keep the area dry during construction.
2) Plum concrete to be completed as shown in the drawing.
3) Backfilling in layers and compaction for full height of the
backfill as directed by the EIC, over the raft projection.
4) Keeping the tank filled with water for at least half the depth.

Providing and laying in position specified grade of reinforced


cement concrete - All work up to plinth level : For Mixture of
1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20
mm nominal size) including the cost of form work, machine
mixing, conveying, placing in position, mechanical
consolidation, finishing, curing, scaffolding, dewatering if
necessary complete all as per drawing & specifications, but
excluding the cost of steel reinforcement (which shall be paid
under relevant item)

20 Item No- a) For RCC work for all structural Members such as Raft , 26.45 Cum
5.1.1 / Pg-96 foundations , all types of Walls, Columns, Beams , Wffle
beams, Slabs, Staircases , Pardis, drop pardis , parapets,
chajjas, nitches etc of any shapes, sizes , thickness and
depths etc. Ratio For Mixture of concrete :- 1:1:2
(Note :- Rate inclusive of all shapes, sizes, curves, slopes,
thickness and depths /heights etc and No extra payment for
shall be payable.)

21 Item No- Rebate over 13 for providing reinforced cement concrete of 26.45 Cum
5.1.2 / Pg-96 grade 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone
aggregate 20 mm nominal size) mix in lieu of M-25 with
approved design.

Page 7
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
22 Reinforcement for RCC work including supplying, delivering
and storing of various diameters as required at site of work
transporting, decoiling, straightening, cutting, bending, placing
in position at all depths, levels and binding with 18-20 gauge,
soft drawn locations annealed steel binding wire complete as
per specifications and drawings. (Cost of binding wire shall be
borne by the contractor & binding wire shall not be measured
for payment. Rate includes cost of tests of materials by
Contractor as specified in the Specifications and IS) and
preparing and obtaining prior approval of bar bending
schedule .

23 Item No- (a) Thermo Mechanically Treated bars of grade Fe-500D 2.48 MT
5.22.6 / Pg- manufactured by recommended list of manufacturers
99 conforming to IS 1786 - latest revision as per specifications of
works and drgs.

Providing, erecting, fixing in position striking / removing and


cleaning steel / plywood or any other approved material
shuttering and centering for formwork in substructure at all
depths for all geometrical shapes, as per details shown in
drawings and as required for specific design of formwork
wherever specified, including proper bracing, ties, anchors,
bolts, nuts, washers, packing plates, fasteners of adequately
designed capacities, producing finished concrete surfaces. at
all locations including chamfers, splays, keys, wedges, props,
rails, bracings, brackets, cutting holes if specified for pipes
etc. providing and applying approved form oil on all surfaces of
formwork coming in contact with concrete including close
hacking of all exposed concrete work wherever required to
receive other type of finishing after removal of form work, all
materials, labour etc.complete as per specifications, drawings
and as directed by the Engineer-in-Charge. (Area of formwork
in contact with concrete shall only be measured for payment
and stop boards for construction joints will not be measured for
payment). Note : - Prior approval of Engineer - in - charge to be
obtained for clearance of form work for laying Rcc.

For Foundation Area


24 Item No- a)Foundations, footings, bases of columns, etc. for mass 182.40 Sq m
5.9.1 / Pg concrete and Raft.
No.- 97

25 Item No- b)Walls (any thickness) including attached pilasters, 27.00 Sq m


5.9.2 / Pg butteresses,
No.- 97 plinth and string courses etc.

26 Item No- c) Lintels, beams, plinth beams, girders, bressumers and 67.77 Sq m
5.9.3 / Pg cantilevers
No.- 97
TOTAL :

D BLOCK MASONRY WORK


Note : -

Page 8
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
(a) All concrete blocks shall be solid and factory made or cast-
at site and the contractor shall get approved the samples of
concrete blocks from the Engineer-In- Charge before
procurement on large scale and shall maintain the same for the
entire work.
The manufacturer shall conform to the requirements IS 2185
Part I latest revsion, shall furnish a certificate to this effect.

b) Necessary Openings/niches/cut-outs, wherever required as


per drawings and asked for by the Engineer-In-Charge, shall
be provided by the contractor without any extra cost.

c) The rate shall include cost of concrete block, labour and


making to all geometrical shapes and sizes, testing,
transporting, wastages, handling, scaffolding ,curing etc without
any extra cost to the Department.

d) The contractor to indemnify IITB for the payment against


taxes, levies, etc in connection with the manufacturing of
concrete block if precast blocks cast at site are used for
construction.

27 Item No- Brick work with common burnt clay machine moulded 4.70 cum
6.3.2 / Pg- perforated bricks of class designation 12.5 conforming to IS:
112 2222 in superstructure above plinth level up to floor five level in
cement mortar 1:6 (1 cement : 6 coarse sand) : (Note: - If
required 100mm.wide and 80mm. thick RCC (1:2:4) stiffeners
to be provided at every 1200mm height including formwork and
providing 2 nos 8mm TMT Fe 500D longitudinally for each
stiffeners as reinforcement bars, the cost of steel
reinforcement, which shall be paid under relevant item)

Total :

Total of Sub Structure Works :

III SUPER STRUCTURE WORK


Super structure items included in this schedule pertains to
all the works above plinth level upto roof including
parapets, water tanks, machine room, terrace level works
etc. unless specified otherwise.
a) All RCC shall be as specified in the respective items and
shall be carried out strictly in accordance with the drawings
and specifications.
b) All coarse aggregate to be 20 mm maximum size and
uniformly graded unless otherwise mentioned
c) For all RCC items, the rates quoted shall include the
following without any extra cost to the Dept.
i) Spacers to maintain clear cover for reinforcement.
ii) Fixing at correct level & in proper alignment the inserts, pipe
sleeves, pipe bends, fan hooks, other pipe specials etc.
supplied by Department or Contractor unless otherwise in a
specified separate item .
iii) Test for concrete shall be done as per IS 456-2000 and the
cost of the same shall be borne by the contractor.

Page 9
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
d) For concrete or masonary surfaces in the areas of expansion
joints, the expansion joint dimension shall be maintained within
tolerance of ± 1.5mm for the entire height of the structure and
special care to be taken in formwork to ensure proper line and
level without any additional cost on this account.

A CONCRETE WORK
Reinforced cement concrete work in walls (any thickness),
including attached pilasters, buttresses, plinth and string
courses, fillets, columns, pillars, piers, abutments, posts and
struts etc. up to floor five level, excluding cost of centering,
shuttering, finishing and reinforcement : : For Mixture of 1:1:2
(1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm
nominal size) including the cost of form work, machine mixing,
conveying, placing in position, mechanical consolidation,
finishing, curing, scaffolding, dewatering if necessary complete
all as per drawing & specifications, but excluding the cost of
steel reinforcement (which shall be paid under relevant item)

28 Item No- a) For RCC work for all structural Members such as Raft , 10.69 Cum
5.2.1 / Pg- foundations , all types of Walls, Columns, Beams , Wffle
96 beams, Slabs, Staircases , Pardis, drop pardis , parapets,
chajjas, nitches etc of any shapes, sizes , thickness and
depths etc. Ratio For Mixture of concrete :- 1:1:2
(Note :- Rate inclusive of all shapes, sizes, curves, slopes,
thickness and depths /heights etc and No extra payment for
shall be payable.)

29 Item No- Rebate over 13 for providing reinforced cement concrete of 10.69 Cum
5.2.2 / Pg-96 grade 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone
aggregate 20 mm nominal size) mix in lieu of M-25 with
approved design.

Reinforced cement concrete work in beams, suspended floors,


roofs having of designed slope, landings, balconies, shelves,
chajjas, lintels, bands, plain window sills,staircases and spiral
stair cases up to floor five level, excluding cost of centering,
shuttering, finishing and reinforcement : : For Mixture of 1:1:2
(1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm
nominal size) including the cost of form work, machine mixing,
conveying, placing in position, mechanical consolidation,
finishing, curing, scaffolding, dewatering if necessary complete
all as per drawing & specifications, but excluding the cost of
steel reinforcement (which shall be paid under relevant item)

30 Item No- a) For RCC work for all structural Members such as Raft , 27.59 Cum
5.1.1 / Pg- foundations , all types of Walls, Columns, Beams , Wffle
96 beams, Slabs, Staircases , Pardis, drop pardis , parapets,
chajjas, nitches etc of any shapes, sizes , thickness and
depths etc. Ratio For Mixture of concrete :- 1:1:2
(Note :- Rate inclusive of all shapes, sizes, curves, slopes,
thickness and depths /heights etc and No extra payment for
shall be payable.)

Page 10
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
31 Item No- Rebate over 13 for providing reinforced cement concrete of 27.59 Cum
5.2.2 / Pg-96 grade 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone
aggregate 20 mm nominal size) mix in lieu of M-25 with
approved design.

Reinforcement for RCC work including supplying, delivering


and storing of various diameters as required at site of work
transporting, decoiling, straightening, cutting, bending, placing
in position at all depths, levels and binding with 18-20 gauge,
soft drawn locations annealed steel binding wire complete as
per specifications and drawings. (Cost of binding wire shall be
borne by the contractor & binding wire shall not be measured
for payment. Rate includes cost of tests of materials by
Contractor as specified in the Specifications and IS) and
preparing and obtaining prior approval of bar bending
schedule .

32 Item No- (a) Thermo Mechanically Treated bars of grade Fe-500D 5.38 MT
5.22.6 / Pg- manufactured by recommended list of manufacturers
99 conforming to IS 1786 - latest revision as per specifications of
works and drgs.

Providing, erecting, fixing in position striking / removing and


cleaning steel / plywood or any other approved material
shuttering and centering for formwork in supertructure at all
depths for all geometrical shapes, as per details shown in
drawings and as required for specific design of formwork
wherever specified, including proper bracing, ties, anchors,
bolts, nuts, washers, packing plates, fasteners of adequately
designed capacities, producing finished concrete surfaces. at
all locations including chamfers, splays, keys, wedges, props,
rails, bracings, brackets, cutting holes if specified for pipes
etc. providing and applying approved form oil on all surfaces of
formwork coming in contact with concrete including close
hacking of all exposed concrete work wherever required to
receive other type of finishing after removal of form work, all
materials, labour etc.complete as per specifications, drawings
and as directed by the Engineer-in-Charge. (Area of formwork
in contact with concrete shall only be measured for payment
and stop boards for construction joints will not be measured for
payment). Note : - Prior approval of Engineer - in - charge to be
obtained for clearance of form work for laying Rcc.

33 Item No- a)Columns, Pillars, Piers, Abutments, Posts and Struts 86.40 Sq m
5.9.6 / Pg
No.- 97

34 Item No- b) Suspended floors, roofs, landings, balconies and access 44.98 Sq m
5.9.3 & 4 / platform & Shelves (Cast in situ)
Pg No.- 97

35 Item No- c) Lintels, beams, plinth beams, girders, bressumers and 91.03 Sq m
5.9.5 / Pg cantilevers
No.- 97

36 Item No- d) Stairs ( excluding landings) except spiral staircases. 0.00 Sq m


5.9.7 / Pg
No.- 97
Page 11
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)

37 Item No- e) Vertical and horizontal fins individually or forming box 15.00 Sq m
5.9.13 / Pg louvers, band, facias and eaves boards
No.- 97
Total :

B SUPER STRUCTURE GENERAL FINISHINGS WORK


BLOCK MASONARY WORK
Note : -
(a) All concrete blocks shall be solid and factory made / cast at
site and the contractor shall get approved the samples of
concrete blocks from the Engineer-In- Charge before
procurement on large scale and shall maintain the same for the
entire work.
The manufacturer shall conform to the requirements IS 2185
Part I latest revsion, shall furnish a certificate to this effect.

b) Necessary Openings/niches/cut-outs, wherever required as


per drawings and asked for by the Engineer-In-Charge, shall
be provided by the contractor without any extra cost.

c) The rate shall include cost of concrete block, labour and


making to all geometrical shapes and sizes, testing,
transporting, wastages, handling, scaffolding ,curing etc without
any extra cost to the Department.

d) The contractor to indemnify IITB for the payment against


taxes, levies, etc in connection with the manufacturing of
concrete block if precast blocks cast at site are used for
construction.

Providing & constructing 200 mm thick steam cured cellular


(aerated) concrete block masonry wit steam cured celluler
concrete block confirming to BIS 6041/6042/6441/3809 having
density not less than 649 kg/ cum in cement mortar 1:6
including adequate plasticizer fornon bearing portion including
raking out joints scaffolding & curing etc complete

38 item no 7, pg a) with 90mm thickness consisting 100mm.wide and 80mm. 233.40 Sqmtr
26, DSR 12- thick RCC (1:2:4) stiffeners at every 1200mm height including
13 formwork and providing 2 nos 8mm TMT Fe 500D longitudinally
for each stiffeners as reinforcement bars, (Note:the cost of
steel reinforcement, which shall be paid under relevant item)

HALF BRICK WALL WITH PLASTER


39 Item No-15.3 Half brick masonry with common burnt clay F.P.S. (non 5.00 Smt
/ Pg-248 & modular) bricks of class designation 7.5 in superstructure
Item No- above plinth level up to floor V level with Cement mortar 1:4 (1
13.3.2 / Pg- cement :4 coarse sand) The rate shall be inclusive of 12 mm
222 cement plaster finished with a floating coat of neat cement of
mix with proportion of 1:4 (1 cement: 4 fine sand)on both side &
110 mm thk RCC patli beam shall run horizontally @ 3'-0" C/C.
also the rate shall inclusive of scafolding required, Curing etc
complete.

Total :

C PLASTERING

Page 12
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
40 EXTERNAL PLASTERING 253.85 Smt
Item No- 18 mm cement plaster in two coats under layer 12 mm thick
13.12 / Pg- cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6
223 mm thick cement plaster 1:3 (1 cement : 3 coarse sand)
finished rough with sponge. The rate shall inclusive of
necessary scaffolding curing etc complete.

41 INTERNAL PLASTERING 253.85 Smt


Item No- 12 mm cement plaster finished with a floating coat of neat
13.7.2/ Pg- cement
222 of mix with proportion of 1:4 (1 cement: 4 fine sand). The rate
shall inclusive of necessary scaffolding curing etc complete.
Total :

D PAINTING
42 Item-13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with 253.85 Sqm
/ Pg-226 Silicone additives of required shade : New work (Two or more
coats applied @ 1.43 ltr/ 10 sqm over and including priming
coat of exterior primer applied @ 2.20 kg/ 10 sqm)

43 RA pg no 71 Providing & applying water proofing cement paint (Sandtex 253.85 Sqm
mat or Eq) on walls of required shade after applying base coat
& primer as per manufacturers specifications in proper line &
level & even colour texture, without patches.
New work (2 or more coats applied @ 3.84 kg/10 sqm)

Total :

E FLOORING

44 Item No- Udaipur Green Marble stone in flooring/ Door Framing for 23.58 Sqm
11.23.5 / Pg- boxing of windows, door frame of toilet with 18 mm thick marble
72 stone, as per sample of marble approved by Engineer-in-
charge, over 20 mm (average) thick base of cement mortar 1:4
(1 cement : 4 coarse sand) laid and jointed with grey cement
slurry, including rubbing and polishing complete with

45 Bd/M-12 P- Providing and fixing 24” X 24” VITRIFIED Tiles of approved 131.48 Sqm
385, pg 51 make, 1st quality & shade and pattern as shown in the drg. In
of DSR 12- CM 1:4 in proper line and level and also using 3mm approved
13 spacers for maintaining the grid lines. Rate shall be inclusive of
providing and laying necessary backing material and joint filling
compound of the same shade of the tiles.Approved mke shall
be Johnson/Nitco/Kajaria or equivalent.

46 Bd/M-12 P- Providing and fixing 12” x 12” Ceramic Tiles of approved make, 39.13 Sqm
385, pg 45 quality & shade and pattern as shown in the drg. In CM 1:4 in
of DSR 12- proper line and level. Rate shall be inclusive of providing and
13 laying necessary backing material and joint filling compound of
the same shade of the tiles

47 RA pg 82 65mm thick Flexi Paver flooring of Basant Betons or equivalent 15.42 Sqm
Basic Price Rs 1100/- per Sqmt in slabs over 20mm average
thick base of cement mortar 1:5 (1cement: 5 coarse sand) with
joints finished flush.

GRANITE SLAB FLOORING (BLACK GALAXY)

Page 13
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
48 Bd/M-16 P- Providing and fixing 1" thick granite slab of approved quality & 3.15 Sqm
387 pg 42, shade for flooring as per approved pattern and according to
DSR 12-13 specified sizes . The rate shall include machine polishing the
edges, necessary backing material, water proofing and joint
filling compound of the same shade as that of the granite slab.

F SKIRTING AND DADO


VITRIFIED TILE SKIRTING
49 Bd/ M-13 P- 4" HIGH 10.23 Sqm
386, pg 51,
DSR 12-13

CERAMIC TILE DADO


50 Bd/M-13 P- Providing and fixing approved shade of ceramic tiles as per pattern for 3.08 Sqm
386, pg 46 of dado from FFL using CM 1:4 in proper line and level as directed by the
DSR 12-13 Architect as shown in the drawings. The rate shall include necessary
backing material, water proofing and joint filling compound of the same
shade as that of the ceramic tiles. All sanitary fittings shall be located on the
joints or junctions of the tiles. Size 300 300 mm

Total :

F DOORS & WINDOW


51 Item 48 pg 89, Providing & fixing in position anodized extruded aluminum 35.10 Sqm
DSR 12-13 openable window having frame out of Aluminum section of
(PWD)
outer frame size 53 x 57 mm (or of required size with
proportionate change in weight) of average weight @ 1.118
kg/Rm and shutter of 53 x 57 mm (or of required size) of
average weight 0.3 kg/ Rmt (or as required) with plain sheet
glass 5.5 mm thick with neoprene gasket with hinges, locking
arrangement & wooden encasement wherever necessary etc,
complete.

52 Item 49 pg 89, Providing & fixing in position extruded modular Aluminum fixed 5.00 Sqm
DSR 12-13 glass panel window having frame made out of extruded tubular
(PWD)
section of size 63 x 38 mm x 2.0 mm thick (wt 1.054 Kg/Rmt)
mechanically assembled at corners with glazing, beading of
angle 25 x 25mm x 1.6 mm thick (wt 0.21 Kg/ Rmt) including
plain sheet glass 5.5 mm thick with rubber gasket and wooden
encasement wherever required, etc as per approved drawing &
specifications etc, complete.
53 Item 54 pg 89, Providing & fixing Aluminum louvred windows consisting of 0.72 sqm
DSR 12-13 vertical arm (40 x 12mm) with holders, lever & locking
(PWD)
arrangement weighing at 0.91 Kg/Rm with 3mm thick sheet
glass louvres etc complete.

54 Bd/U-1 P- P & F MS Grills for all windows as per approved design & 40.10 Sqm
537, pg 105, Pattern with enamel paint of approved shade as directed made
DSR 12-13 out of MS flats strips of size about 25x 4mm in pattern as
shown in the drg. The flats mentioned above to be intrespersed
with MS square bars of size 10x10mm in design. The grill thus
to be fixed to the wall/ beam/ column of the existing structure
with anchor bolts & the cost to also include that for welding as
required on site & all necessary hardware such as screws,
welding rods, etc as per directions of the architect. Rate
inclusive of wrought Iron decorative elements as given in
drawing and directions.Rate inclusive of applying red oxide to
the grill and finishing the same with black colour oil/enamel
paint.complete

Page 14
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
55 Extra for providing Nylon /GI Mosquito Netting of approved 35.10 Sqm
make & as per directions.Vertically Sliding system to be
installed inside the openable window with aluminum pipe
framing 65mmx40mm and 25mmx25mm as required and
sliding chanels on two sides .the net to have end PVC end
channel and hook.Complete as per drawing and directions .

SOLID DOORS-
3-0" x 7'-0" -
56 Bd/T-34P-499, Providing & Fixing solid core flush door in single leaf 35 mm 9.45 Sqm
pg 84 of DSR thick decorative type of exterior grade as per detailed drawings,
12-13
approved face veneer on both sides withoutglazing and
venetians, all necessary beads, mouldings and lipings on
edges of the shutter of matching width, brass oxidiesd fixtures
and fastenings with mortise lock, chromium plated handles on
both sides and finishing with ffrench polish, etc complete.

DOOR FRAME WITH JAMB LINING


57 BD/T-2 P-478, Providing& Fixing as pper drawing for second class doors, 0.38 Cum
pg 81 of DSR windows, fan lights, etc including all mouldings, rebating,
12-13
holdfasts, and finishing with one coat of primer complete.
Country Teak wood frame
Size 0.90m x 2.10m Ht

Total :

G STEEL WORK
58 Item No-10.1 Structural steel work in single section, fixed with or without 5.83 Tons
/ Pg-176 connecting plate, including cutting, hoisting, fixing in position
and applying a priming coat of approved steel primer as per
drawings &or as directed by enginner incharge. The rates shall
be inclusive of cutting, Fabricating, hoisting, erecting fixing in
position, Making riveted/bolted/welded connections &
scaffolding etc all complete

59 Providing & fixing double layered Precoated Galvalume/ GI 0.00 Sqm


Roof Sheeting made out of Plain precoated Galvalume sheet
0.5 mm thick for the base & 0.5 mm thick precoated profiled
(corrugated ) sheet on top with a gap of 75 mm thick between
the two sheets. The gap between the two sheets to be filled
with Insulating material of PUFF of density as per
manufacturers specifications. The cost to include that for all
necessary screws, bolts, washers, scaffolding, etc complete

Total :

H WATER PROOFING
60 WATER PROOFING-upto depth of 450mm 10.98 Cum
Item 7, pg Providing and laying integral cement based water proofing
30, DSR 12- treatment
13 including preparation of surface as required for treatment of
roofs,
balconies, terraces etc consisting of following operations:
upto 300 mm height including cleaning the surface before
treatment.

Page 15
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
a) Applying a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with water proofing compound conforming to
IS. 2645 and approved by Engineer-in-charge over the RCC
slab including adjoining walls
b) Laying brick bats with mortar using broken bricks/brick bats
25 mm to 115 mm size with 50% of cement mortar 1:5 (1
cement : 5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-
in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1
cement :5 coarse sand ) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-
in-charge to required slope and treating similarly the adjoining
walls upto 300 mm height including rounding of junctions of
walls and slabs

c) After two days of proper curing applying a second coat of


cement slurry using 2.75 kg/ sqm of cement admixed with
water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge.
d) Finishing the surface with 20 mm thick jointless cement
mortar of mix 1:4 (1 cement :4 coarse sand) admixed with
water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge including laying glass fibre
cloth of approved quality in top layer of plaster and finally
finishing the surface with trowel with neat cement slurry and
making pattern of 300x300 mm square 3 mm deep.

e) The whole terrace so finished shall be flooded with water for


a minimum period of two weeks for curing and for final test. All
above operations to be done in order and as directed and
specified by the Engineer-in-Charge :

61 Providing & fixing PVC rain water pipes 110 mm dia pipes 24.00 Rm
having wall thickness of 2.2 to 2.7 mm conforming to IS 13592-
1992 including proper rain water receiving recess with PVC
plug bend, necessary fittings such as offsets, shoes including
fixing the pipes on wall using approved wooden cleats
projecting 25 to 40 mm from face of wall AAnd fixing with clips
of approved quality & number, filling the joints using rubber
gasket with solvent cement & prooperly resting the shoe of
pipes on CC or masonry blocks,including necessary scaffolding
& maintenance for 3 years for any leakages or dislocation of
pipes. All the PVC fittings & additionaltwo piece socket clips
shall be got approved from Engineer in chargeetc, complete.

62 Water proofing treatment to external walls as follows. Breaking 50.00 Sqm


open the cracks in the wall, Clean the surface for treatment by
removing dust, dirt and layers of concrete, plaster, etc over the
walls,slab, beams, etc. Providing and applying three coats of
"POLYALK WP" of M/s. Sunanada Speciality Coating Pvt.and
cement in 1"1"25 ratio at an interval of 24 hours on the wall.
Cost to include that for necessary scaffolding,covering of all
sides with hessian cloth platforms, curing, etc.

63 Repairing of RCC members including breaking & chieseling out 29.00 Sqm
plaster, loose concrete,appliny rust remover, polymer etc,
complete & finishing the surface as directed.

Page 16
SR. DSR Ref No DESCRIPTION QTY. UNIT RATE AMOUNT (Rs.)
NO (Rs.)
64 Bd/M-21 P- Providing & laying China mosaic tretment with broken glazed/ 73.23 Sqm
390, pg 48 ceramic tiles in proper workmanlike manner and laid to slopes
of DSR 12- including 20mm thick bedding material in CM 1:6 with cleaning
13 the surface & leaving the surface stainfree, etc complete.

Total :

Page 17
MEASURMENT SHEET

Extension of A1 Building For IIT-B Within IIT-B Campus Powai, Mumbai-400 076

SR. DESCRIPTION Nos L B H Qtty Remarks


NO

I Dismantling and Demolition


1 Dismantling tile work in floors and roofs 1 12.85 3.5 44.98 Verandah Area
1 4.8 1.5 7.20 Living area
1 4.1 1.5 6.15 Bedroom
58.33
5.83 Add 10 % extra
64.16 Sqm

2 Demolishing brick work in cement mortar/ Water proofing 1 7.7 0.4 4 12.32 Periferral wall of Liv &
manually/ by mechanical means dining
1 4.1 0.4 4 6.56 Periferral wall of
Bedroom
18.88
1.89 Add 10 % extra
21 Cum

3 Demolishing R.C.C. work manually/ by mechanical means 1 11.8 1.2 0.15 2.12 Slab
0.64 Add 30% more for chajjas
2.76 Cum

4 Dismatling aluminium /gypsum partitions ,doors 2 2 2.1 8.40 Windows in Living & Din
,windows,fixed glazing and false ceiling

1 1 1.5 1.50 Window in Bed


9.90
1 Add 10 % extra
11 Sqm
II SUB STRUCTURE WORKS

A Excavation & Earth Works


4 Earth work excavation by mechanical means / labour
means for foundation pits, trenches etc. in all types of
soils other than soft and hard rock
a) Depth not exceeding 1.50 m. from ground level. 10 2.7 2.7 1.5 109.35 Column foundations
1 43.8 0.6 0.6 15.77 Plinth beams
125.12
12.51
137.63

b) Depth exceeding 1.5m & up to 3m from ground level 10 2.7 2.7 1 72.90 Column foundations
7.29
80.19

c) Depth exceeding 3.0 m & up to 4.5m from ground Column foundations for
level staircase

5 Earth work excavation by mechanical means /labour


means for foundation pits, trenches etc. in soft rock
a) Depth not exceeding 1.50 m. from ground level.

b) Depth exceeding 1.5m & up to 3m from ground level 10.00 2.7 2.7 0.3 21.87 Column foundations
2.19
24.06
c) Depth exceeding 3.0 m & up to 4.5m from ground
level

6 Earth work excavation by mechanical means /labour


means for foundation trenches etc. in hard rock
including Concrete structure if any.
a) Depth not exceeding 1.50 m. from ground level. 2.7 2.7 0.3 2.19 Column foundations

b) Depth exceeding 1.5m & up to 3m from ground level 2.7 2.7 0.3 2.19 Column foundations

c) Depth exceeding 3.0 m & up to 4.5m from ground


level

7 Filling in plinth with murrum/ selected earth 172.71 Column foundations


approved by Engineer-in-charge excavated from
nearby borrow areas
1.00 12.85 3.50 0.60 26.99 Plinth for Extension
1.00 11.80 1.50 0.60 10.62 Refilling in Plinth
1.00 4.10 1.50 0.60 3.69 Refilling in Plinth
214.01
21.40
235.41

8 Providing and laying dry rubble stone hard core soling 10 1.5 1.5 22.50 Column foundations
of 230mm thickness
1.00 12.85 3.50 0.23 10.34 Plinth for Extension
1.00 11.80 1.50 0.23 4.07 Refilling in Plinth
1.00 4.10 1.50 0.23 1.41 Refilling in Plinth
38.33
3.83
42.16

9 Disposing off the surplus excavated materials by


mechanical transport lead up to 2 KM to the nearby
dumping pits/ dumping areas with in IITB campus
identified by Engineer in charge , including all lifts,
loading, unloading, stacking etc. complete as per
specifications & as directed by the EIC.

a) all type of Soil 182.25

b) Soft rock & Hard rock 26.24

B Plain Cement Concrete & Plum concrete


10 Providing and laying in position cement concrete of 10 1.5 1.5 0.15 3.38 Column foundations
specified grade excluding the cost of centering and
shuttering - All work up to plinth level : For 1:4:8 (1
Cement : 4 coarse sand : 8 graded stone aggregate 40 mm
nominal size)
1 57.8 0.3 0.15 2.60 Below Plinth beams
Total: 5.98

C Reinforced Cement Concrete


11 Providing and laying in position specified grade of 10 1.2 1.2 0.6 8.64 Column foundations for
reinforced cement concrete - All work up to plinth level : staircase
For Mixture of 1:1:2 (1 cement : 1 coarse sand : 2 graded
stone aggregate 20 mm nominal size) including the cost of
form work, machine mixing, conveying, placing in position,
mechanical consolidation, finishing, curing, scaffolding,
dewatering if necessary complete all as per drawing &
specifications, but excluding the cost of steel reinforcement
(which shall be paid under relevant item)

10 0.3 0.5 0.6 0.90 Column Below plinth


1 57.8 0.45 0.3 7.80 Plinth Beams
1 12.85 3.5 0.15 6.75 Slab on dining
1 4.1 1.5 0.15 0.92 Slab on bed
1 23.95 0.6 0.1 1.44 Chajja
Total: 26.45

12 Rebate over 13 for providing reinforced cement concrete 26.45


of grade 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded
stone aggregate 20 mm nominal size) mix in lieu of M-25
with approved design.

13 Reinforcement for RCC work


(a) Thermo Mechanically Treated bars of grade Fe-500D 432.00 Footings(50 Kg/Cum)
manufactured by recommended list of manufacturers
conforming to IS 1786 - latest revision as per
specifications of works and drgs.
180.00 Columns (200 Kg/Cum)
1170.45 Beams (150 Kg/Cum)
613.50 Slabs (80 Kg/ Cum)
86.22 Chajja (60 Kg/cum)
Total: 2482.17 (Kg)
Total: 2.48 MT

14 Providing, erecting, fixing in position striking / removing


and cleaning steel / plywood or any other approved
material shuttering and centering for formwork in
substructure at all depths
For Foundation Area
a)Foundations, footings, bases of columns, etc. for mass 40.00 1.20 0.60 28.80 Footings
concrete and Raft.
40.00 1.60 2.40 153.60 Column Bases Below
Plinth(1.6=0.3+0.3+0.5+
0.5)
Total: 182.40

b)Walls (any thickness) including attached pilasters, 27.00 Nominal quantity


butteresses,
plinth and string courses etc.

c) Lintels, beams, plinth beams, girders, bressumers and 1.00 57.80 1.00 57.80 Plinth Beams
cantilevers
8.67 Add 15% for lintels
1.00 23.95 0.60 1.30 Chajja
67.77
D BLOCK MASONRY WORK

15 Brick work with common burnt clay machine moulded 30.95 0.23 0.45 3.20 New Plinth
perforated bricks of class designation 12.5 conforming to
IS: 2222 in superstructure above plinth level up to floor five
level in cement mortar 1:6 (1 cement : 6 coarse sand) :
(Note: - If required 100mm.wide and 80mm. thick RCC
(1:2:4) stiffeners to be provided at every 1200mm height
including formwork and providing 2 nos 8mm TMT Fe 500D
longitudinally for each stiffeners as reinforcement bars, the
cost of steel reinforcement, which shall be paid under
relevant item)

1.50 Nominal
Total: 4.70

III SUPER STRUCTURE WORK


A CONCRETE WORK
16 Reinforced cement concrete work in walls (any thickness), 10 0.3 0.45 7.2 9.72 columns
including attached pilasters, buttresses, plinth and string
courses, fillets, columns, pillars, piers, abutments, posts
and struts etc. up to floor five level, excluding cost of
centering, shuttering, finishing and reinforcement : : For
Mixture of 1:1:2 (1 cement : 1 coarse sand : 2 graded
stone aggregate 20 mm nominal size) including the cost of
form work, machine mixing, conveying, placing in position,
mechanical consolidation, finishing, curing, scaffolding,
dewatering if necessary complete all as per drawing &
specifications, but excluding the cost of steel reinforcement
(which shall be paid under relevant item)

0.97
Total: 10.69

17 Rebate over 13 for providing reinforced cement concrete 10.69


of grade 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded
stone aggregate 20 mm nominal size) mix in lieu of M-25
with approved design.

18 Reinforced cement concrete work in beams, suspended 1.00 57.80 0.3 0.45 7.80 Periferral Beams
floors, roofs having of designed slope, landings, balconies,
shelves, chajjas, lintels, bands, plain window
sills,staircases and spiral stair cases up to floor five level,
excluding cost of centering, shuttering, finishing and
reinforcement : : For Mixture of 1:1:2 (1 cement : 1 coarse
sand : 2 graded stone aggregate 20 mm nominal size)
including the cost of form work, machine mixing,
conveying, placing in position, mechanical consolidation,
finishing, curing, scaffolding, dewatering if necessary
complete all as per drawing & specifications, but excluding
the cost of steel reinforcement (which shall be paid under
relevant item)

1 12.85 3.5 0.15 6.75 Slab over Dining


1 4.8 3.5 0.15 2.52 Slab over store
1 4.8 4.5 0.15 3.24 Slab over bed on terrace
2 4.1 1.5 0.15 1.85 Slab over bed
1 7.7 1.5 0.15 1.73 part slab over Ex liv/din
2 4.1 1.5 0.15 1.85 Part slabover bed
1 30.95 0.6 0.1 1.86 Chajja
Total: 27.59

19 Rebate over 13 for providing reinforced cement concrete 27.59


of grade 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded
stone aggregate 20 mm nominal size) mix in lieu of M-25
with approved design.

20 Reinforcement for RCC work


(a) Thermo Mechanically Treated bars of grade Fe-500D 2138.40 Columns (200 Kg/Cum)
manufactured by recommended list of manufacturers
conforming to IS 1786 - latest revision as per
specifications of works and drgs.
2182.39 Beams (150 Kg/Cum)
973.50 SLABS (80 Kg/Cum)
86.63 Pardis (50 Kg/Cum)
Total: 5380.91 (KG)
Total: 5.38 MT
21 Providing, erecting, fixing in position striking / removing
and cleaning steel / plywood or any other approved
material shuttering and centering for formwork in
superstructure

a) a)Columns, Pillars, Piers, Abutments, Posts and Struts 8 1.5 7.2 86.40 Staircase Column
Total: 86.40

b) b) Suspended floors, roofs, landings, balconies and access 1 12.85 3.5 44.98 Slab over Dining
platform & Shelves (Cast in situ)
1 4.8 3.5 16.80 Slab over store
1 4.8 4.5 21.60 Slab over bed on terrace
2 4.1 1.5 12.30 Slab over bed
1 7.7 1.5 11.55 part slab over Ex liv/din
2 4.1 1.5 12.30 Part slabover bed
119.53

c) c) Lintels, beams, plinth beams, girders, bressumers and 1.00 57.80 1.2 69.36 Beams
cantilevers
1.00 30.95 0.7 21.67 Chajja
Total: 91.03

d) d) Stairs ( excluding landings) except spiral staircases.

e) e) Vertical and horizontal fins individually or forming box 15.00 Nominal Quantity
louvers, band, facias and eaves boards

B SUPER STRUCTURE GENERAL FINISHINGS WORK


BLOCK MASONARY WORK

22 Providing & constructing 200 mm thick steam cured cellular 1 30 8.2 246.00
(aerated) concrete block masonry wit steam cured celluler
concrete block confirming to BIS 6041/6042/6441/3809
having density not less than 649 kg/ cum in cement mortar
1:6 including adequate plasticizer fornon bearing portion
including raking out joints scaffolding & curing etc complete
-12.60 Less for windows
233.40 Sqm
53.68 Cum

23 HALF BRICK WALL WITH PLASTER 5.00 Nominal Qtty

C PLASTERING
24 EXTERNAL PLASTERING 253.85

25 INTERNAL PLASTERING 253.85

D PAINTING
26 Finishing walls with Premium Acrylic Smooth exterior paint 253.85
with Silicone additives of required shade : New work (Two
or more coats applied @ 1.43 ltr/ 10 sqm over and
including priming coat of exterior primer applied @ 2.20 kg/
10 sqm)

E FLOORING

27 Udaipur Green Marble stone in flooring/ Door Framing for 3 6.2 0.3 5.58 Window Jambs
boxing of windows, door frame of toilet with 18 mm thick
marble stone, as per sample of marble approved by
Engineer-in-charge, over 20 mm (average) thick base of
cement mortar 1:4 (1 cement : 4 coarse sand) laid and
jointed with grey cement slurry, including rubbing and
polishing complete with

10 6 0.3 18.00 Window Jambs


23.58 Sqm
Vitrified Tile Flooring 1 12.85 3.5 44.98 Dining
1 4.8 3.5 16.80 Store
1 4.8 4.5 21.60 Terrace Bed
2 4.1 1.5 12.30 Bed extension
1 7.7 1.5 11.55 Damaged portion in Liv
2 4.1 1.5 12.30 Damaged portion in bed
119.53
11.95
131.48 Sqm

Ceramic Tile Flooring 1 7.85 3.5 27.48 terrace on 1st flr


1 2.7 3 8.10 terrace on 1st flr
35.58
3.56
39.13 Sqm

Vitrified Skirting 1 43 0.1 4.30 Ground Floor


1 50 0.1 5.00 First floor
9
0.93
10.23 Sqm

Ceramic Tile Skirting 1 28 0.1 2.80 Terrace


0.28
3.08 Sqm
F WINDOW
28 Providing & fixing in position anodized extruded aluminum 3 2 2.1 12.60 Window Surface
openable window having frame out of Aluminum section of
outer frame size 53 x 57 mm (or of required size with
proportionate change in weight) of average weight @ 1.118
kg/Rm and shutter of 53 x 57 mm (or of required size) of
average weight 0.3 kg/ Rmt (or as required) with plain
sheet glass 5.5 mm thick with neoprene gasket with
hinges, locking arrangement & wooden encasement
wherever necessary etc, complete.

10 1.5 1.5 22.50


35.10

29 Providing & fixing in position extruded modular Aluminum 5.00 Nominal Qtty
fixed glass panel window having frame made out of
extruded tubular section of size 63 x 38 mm x 2.0 mm thick
(wt 1.054 Kg/Rmt) mechanically assembled at corners with
glazing, beading of angle 25 x 25mm x 1.6 mm thick (wt
0.21 Kg/ Rmt) including plain sheet glass 5.5 mm thick with
rubber gasket and wooden encasement wherever required,
etc as per approved drawing & specifications etc,
complete.

30 Providing & fixing Aluminum louvred windows consisting of 1 0.6 1.2 0.72
vertical arm (40 x 12mm) with holders, lever & locking
arrangement weighing at 0.91 Kg/Rm with 3mm thick sheet
glass louvres etc complete.

G STEEL WORK
31 Structural steel work in single section, fixed with or without 5.83 100 Kg per sq m
connecting plate, including cutting, hoisting, fixing in
position and applying a priming coat of approved steel
primer as per drawings &or as directed by enginner
incharge. The rates shall be inclusive of cutting,
Fabricating, hoisting, erecting fixing in position, Making
riveted/bolted/welded connections & scaffolding etc all
complete
32 Providing & fixing double layered Precoated Galvalume/ GI
Roof Sheeting made out of Plain precoated Galvalume
sheet 0.5 mm thick for the base & 0.5 mm thick precoated
profiled (corrugated ) sheet on top with a gap of 75 mm
thick between the two sheets. The gap between the two
sheets to be filled with Insulating material of PUFF of
density as per manufacturers specifications. The cost to
include that for all necessary screws, bolts, washers,
scaffolding, etc complete

0.00 Add 40% for overhang &


slopes
0.00

H WATER PROOFING
33 WATER PROOFING-upto depth of 450mm 1 13 4 0.15 6.75 Terrace
1 5 5 0.15 3.24 Terrace
9.99
1.00
10.98 Cum

34 Providing & fixing PVC rain water pipes 110 mm dia pipes 3 8 24.00 Rain water down take
having wall thickness of 2.2 to 2.7 mm conforming to IS pipes
13592-1992 including proper rain water receiving recess
with PVC plug bend

You might also like