FROM THE FIGURE, AN ANGULAR SECTION 100 mm X 75 mm X

6.25 mm IS RIVETED BY 19 mm DIAMETER RIVETS ARRANGED


AS INDICATED. ASSUME A36 STEEL WITH AN Fy = 248 MPa.
AND Fu = 400 MPa. DIAMETER OF HOLE IS 3 mm GREATER
THAN THE RIVET DIAMETER

75

43.75 31.25 75 75

62.5
100
T

37.5 37.5 37.5 37.5 37.5

DETERMINE THE CAPACITY OF THE SECTION BASED ON


YIELDING OF GROSS AREA
DETERMINE THE CAPACITY OF THE SECTION BASED ON
TENSILE FRACTURE OF THE NET AREA
DETERMINE THE CAPACITY OF THE SECTION BASED ON
BLOCK SHEAR FAILURE
DETERMINE THE CAPACITY OF THE SECTION BASED ON
BEARING STRESS BETWEEN THE PLATES
DETERMINE THE CAPACITY OF THE SECTION BASED ON
SHEAR STRESS OF THE RIVETS IF THE SHEAR STRENGTH OF
THE RIVETS IS Fv = 200 MPa