FROM THE FIGURE, AN ANGULAR SECTION 100 mm X 75 mm X
6.25 mm IS RIVETED BY 19 mm DIAMETER RIVETS ARRANGED
AS INDICATED. ASSUME A36 STEEL WITH AN Fy = 248 MPa. AND Fu = 400 MPa. DIAMETER OF HOLE IS 3 mm GREATER THAN THE RIVET DIAMETER
75
43.75 31.25 75 75
62.5 100 T
37.5 37.5 37.5 37.5 37.5
DETERMINE THE CAPACITY OF THE SECTION BASED ON
YIELDING OF GROSS AREA DETERMINE THE CAPACITY OF THE SECTION BASED ON TENSILE FRACTURE OF THE NET AREA DETERMINE THE CAPACITY OF THE SECTION BASED ON BLOCK SHEAR FAILURE DETERMINE THE CAPACITY OF THE SECTION BASED ON BEARING STRESS BETWEEN THE PLATES DETERMINE THE CAPACITY OF THE SECTION BASED ON SHEAR STRESS OF THE RIVETS IF THE SHEAR STRENGTH OF THE RIVETS IS Fv = 200 MPa