Professional Documents
Culture Documents
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
CM500 Total ECM Time (Key On Time) 27019:56:21 HH:MM:SS
Total Engine Hours (Engine Run
24357:34:30 HH:MM:SS
Time)
Keyoffs 12482
SPN
1384
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Intermediate Speed Control 1
Off Off
Switch
Intermediate Speed Control 2
Off Off
Switch
Intermediate Speed Control 3
Off Off
Switch
Intermediate Speed Control
None None
Validation
Key Switch Off Off
Percent Throttle 0 0 Percent
Percent Torque 17.21 27.96 Percent
Rail Feedback Current 0.570800 0.582300 A
Rail Pressure 1.3 1.2 bar
Remote Throttle Switch Off Off
Solenoid A On On
Solenoid B Off Off
Timing Feedback Current 0.853800 0.773900 A
Timing Pressure 3.5 3.4 bar
Torque Curve Selection 0 0
Accelerator Pedal / Lever Position Sensor Circuit -
0132 Inactive 19 Red 91 4
Shorted Low
Total Engine Hours (Engine Run
24148:55:11 24356:28:20 HH:MM:SS
Time)
Alternate Droop Switch Undefined 3
Alternate Low Idle Speed Switch Off Off
Alternate Torque Switch 2 3
Battery Voltage 8.5 11.8 V
Boost Power Engaged Off Off
Coolant Level High High
Coolant Temperature 74.6 84.7 C
SPN
91
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Desired Rail Fueling 0.00 0.00 Percent
Desired Timing Fueling 25.17 25.17 Percent
Diagnostic Switch Off Off
Engine Oil Pressure 7.6 6.2 kPa
Engine Operating State Datalink Torque Datalink Torque
Engine Speed 0 35 RPM
Estimated Rail Fueling 4.32 4.28 Percent
Estimated Timing Fueling 5.33 11.54 Percent
Fuel Pump Feedback Current 0.5 0.5 A
Fuel Pump Output Pressure 1.1 3.1 bar
Idle Increment Switch None None
Idle Validation Status On Idle On Idle
Intake Manifold Pressure 2.7 2.7 kPa
Intake Manifold Temperature 68.9 53.3 C
Intermediate Speed Control 1
Off Off
Switch
Intermediate Speed Control 2
Off Off
Switch
Intermediate Speed Control 3
Off Off
Switch
Intermediate Speed Control
None None
Validation
Key Switch On On
Percent Throttle 16 16 Percent
Percent Torque 0.00 0.00 Percent
Rail Feedback Current 0.340800 0.395300 A
Rail Pressure 1.0 1.0 bar
Remote Throttle Switch Off Off
Solenoid A Off Off
Solenoid B On On
SPN
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Timing Feedback Current 0.440400 0.449000 A
Timing Pressure 0.8 1.0 bar
Torque Curve Selection 0 0
0346 Inactive 44 Amber Engine Control Module - Warning Software Error 253 12
SPN
630
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Intermediate Speed Control 1
Off Off
Switch
Intermediate Speed Control 2
Off Off
Switch
Intermediate Speed Control 3
Off Off
Switch
Intermediate Speed Control
None None
Validation
Key Switch Off Off
Percent Throttle 100 100 Percent
Percent Torque 0.00 0.00 Percent
Rail Feedback Current 0.282500 0.002900 A
Rail Pressure 3.8 1.9 bar
Remote Throttle Switch Off Off
Solenoid A Off Off
Solenoid B Off Off
Timing Feedback Current 0.055700 0.038800 A
Timing Pressure 3.8 0.9 bar
Torque Curve Selection 0 0
Engine Timing Actuator is not responding to
0112 Inactive 1 Red 20 7
ECM commands
Total Engine Hours (Engine Run
24231:38:40 24231:38:40 HH:MM:SS
Time)
Alternate Droop Switch 3 3
Alternate Low Idle Speed Switch Off Off
Alternate Torque Switch 3 3
Battery Voltage 26.6 26.6 V
Boost Power Engaged Off Off
Coolant Level High High
Coolant Temperature 83.8 83.8 C
SPN
635
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Desired Rail Fueling 44.53 44.53 Percent
Desired Timing Fueling 27.91 27.91 Percent
Diagnostic Switch Off Off
Engine Oil Pressure 412.3 412.3 kPa
Progressive Shift Progressive Shift
Engine Operating State
Speed Speed
Engine Speed 875 875 RPM
Estimated Rail Fueling 17.03 17.03 Percent
Estimated Timing Fueling 76.33 76.33 Percent
Fuel Pump Feedback Current 0.7 0.7 A
Fuel Pump Output Pressure 18.0 18.0 bar
Idle Increment Switch None None
Idle Validation Status On Idle On Idle
Intake Manifold Pressure 15.2 15.2 kPa
Intake Manifold Temperature 63.9 63.9 C
Intermediate Speed Control 1
Off Off
Switch
Intermediate Speed Control 2
Off Off
Switch
Intermediate Speed Control 3
Off Off
Switch
Intermediate Speed Control
None None
Validation
Key Switch On On
Percent Throttle 33 33 Percent
Percent Torque 9.11 9.11 Percent
Rail Feedback Current 0.735400 0.735400 A
Rail Pressure 1.5 1.5 bar
Remote Throttle Switch Off Off
Solenoid A On On
SPN
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Solenoid B Off Off
Timing Feedback Current 0.779500 0.779500 A
Timing Pressure 9.4 9.4 bar
Torque Curve Selection 0 0
SPN
633
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Intake Manifold Temperature 49.6 48.1 C
Intermediate Speed Control 1
On Off
Switch
Intermediate Speed Control 2
Off Off
Switch
Intermediate Speed Control 3
Off Off
Switch
Intermediate Speed Control
None None
Validation
Key Switch On On
Percent Throttle 100 0 Percent
Percent Torque 100.00 100.00 Percent
Rail Feedback Current 1.126700 0.879900 A
Rail Pressure 3.2 1.1 bar
Remote Throttle Switch Off Off
Solenoid A On Off
Solenoid B Off On
Timing Feedback Current 0.750200 1.088100 A
Timing Pressure 3.3 1.3 bar
Torque Curve Selection 0 0
SPN
190
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Coolant Temperature 82.4 81.7 C
Desired Rail Fueling 1.32 1.32 Percent
Desired Timing Fueling 40.96 40.96 Percent
Diagnostic Switch Off Off
Engine Oil Pressure 503.3 476.4 kPa
Engine Operating State User Command User Command
Engine Speed 2123 2107 RPM
Estimated Rail Fueling 24.39 17.93 Percent
Estimated Timing Fueling 66.64 40.13 Percent
Fuel Pump Feedback Current 0.1 0.5 A
Fuel Pump Output Pressure 25.3 20.0 bar
Idle Increment Switch None None
Idle Validation Status On Idle On Idle
Intake Manifold Pressure 53.5 40.3 kPa
Intake Manifold Temperature 54.8 51.4 C
Intermediate Speed Control 1
Off Off
Switch
Intermediate Speed Control 2
Off Off
Switch
Intermediate Speed Control 3
Off Off
Switch
Intermediate Speed Control
None None
Validation
Key Switch On On
Percent Throttle 100 100 Percent
Percent Torque 0.00 0.00 Percent
Rail Feedback Current 0.314500 0.332800 A
Rail Pressure 3.3 2.5 bar
Remote Throttle Switch Off Off
Solenoid A On On
SPN
Fault Code Status Count Lamp Description PID SID J1587 FMI J1939 FMI
Fault Parameters First Last Units
Solenoid B Off Off
Timing Feedback Current 0.940200 0.864500 A
Timing Pressure 22.2 9.8 bar
Torque Curve Selection 0 0
SPN