You are on page 1of 2

Faults Information

Engine Serial Number : 0 INSITE 7.6.1.195


Customer Unit Number : 93070 Company Name : Cummins
Work Order Name : NA ECM Image Name : NA
Customer Name :

J1587 J1939
Fault Code Status Count Lamp Description PID SID SPN
FMI FMI

Fault Parameters First Last Units

CM875 ECM Time 15225:01:07 HH:MM:SS

Engine Hours 15029:38:43 HH:MM:SS

Keyoffs 34782

Accelerator Pedal or Lever Idle Validation


0431 Active 1 Amber Circuit - Data erratic, intermittent or 230 2 2 558
incorrect

Change Lubricating Oil and Filter -


0649 Active 1 Maintenance 153 11 31 1378
Condition Exists

SAE J1939 Multiplexing PGN Timeout


0285 Active 255 Amber 231 9 9 639
Error - Abnormal update rate

Exhaust Pressure Sensor Circuit - Data


2554 Active 255 Amber 131 2 2 1209
erratic, intermittent or incorrect

Engine Fuel Shutoff Valve Circuit - Voltage


0255 Active 1 Amber 17 3 3 632
above normal, or shorted to high source

EGR Valve Control Circuit - Current below


2349 Active 255 Amber 146 5 5 2791
normal or open circuit

Engine Control Module Critical internal


0111 Active 1 Red failure - Bad intelligent device or 254 12 12 629
component

07:53:00 PM Page 1 of 2 01-Dec-2022


Faults Information
Engine Serial Number : 0 INSITE 7.6.1.195
Customer Unit Number : 93070 Company Name : Cummins
Work Order Name : NA ECM Image Name : NA
Customer Name :

J1587 J1939
Fault Code Status Count Lamp Description PID SID SPN
FMI FMI

Fault Parameters First Last Units

Power Lost without Ignition Off - Data


0434 Active 85 Amber 251 2 2 627
erratic, intermittent or incorrect

07:53:00 PM Page 2 of 2 01-Dec-2022