BOD Cl. 5.4.1 Peak ground acceleration a = 0.150 g Design acceleration ag= 0.195 g Elastic response spectra Type = 1 Behaviour factor q = 2.0 Lower bound factor for the horizontal design spectrum b = 0.2
Values of the parameters describing the recommended Type 1 elastic response spectra
Ground type S TB(s) TC(s) TD(s)
A 1 0.15 0.4 2 B 1.2 0.15 0.5 2 C 1.2 0.2 0.6 2 D 1.4 0.2 0.8 2 E 1.4 0.15 0.5 2
Ground type Type = C (Since N is less than 15)
Soil factor, S = 1.15 Lower limit of the period of the TB = 0.20 constant spectral acceleration, Upper limit of the period of the TC = 0.60 constant spectral acceleration,
Value defining the beginning of the TD = 2.00
constant displacement response range of the spectrum,
Clause 3.2.2.5 Horizontal factor of the seismic component, the design spectrum, S d(T) as below:
Node 30
Therefore Sd(t) = 0.280 Based on equation 2 (X-dir.)
Comparison of a steel column design buckling resistance between the South African/Canadian (SANS 10162-1:2005/CAN/CSA-S16- 01:2005), Eurocode 3 (EN 1993-1-1:2005) and Australian /New Zealand (AS4100:1998/NZS3404:1997) standards- Part II: South African Hot-Rolled I- Section