CONSTRUCTION OF FLOWLINES AND WELLHEAD

TIE-IN INSTALLATIONS AT ADCO’s FIELD (PACKAGE-"C")


(Project No:12335 & Contract No:16392.03 )
WELDING INSPECTION REPORT (PIPE LINE)
REPORT No: BQ 42-WIR-98 DATE: 1/4/2019 LOCATION : BQ 42
DRAWING No:12/78/07/0627/REV B CHAINAGE : FROM:08+500 TO:08+700
WELDING PROCESS: SMAW SERVICE : OIL Filler Metal Batch :
Pipe Dia & Thickness: 6" x 14.27 mm (API 5L GR.B) Accp Criteria: ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017&

Length of Type of Welders


Date of Fitup Pre-Heat Inter Pass
Pipe No. Heat No. Material Pipe in Bend - Weld No. WPS
Inspection Temp (°C) Temp (°C)
meters Degree
R&H F

4509 TD7744V 1 11.82 SP


PL-WPS-023
KP-08-MJ-727 04.01.2019 Rev.2
110°C <220 217/205 217/205
5010 TD7893V 1 11.8 HB-45

5010 TD7893V 1 11.8 HB-45


PL-WPS-024
KP-08-FTJ-728 04.01.2019 150°C <250 217/205 217/205
4117 TD7726V 1 11.82 HB-45

4117 TD7726V 1 11.82 HB-45


PL-WPS-024
KP-08-FTJ-729 04.01.2019 150°C <250 217/205 217/205
2719 TD7715V 1 11.84 HB-45

2719 TD7715V 1 11.84 HB-45


PL-WPS-024
KP-08-FTJ-730 04.01.2019 150°C <250 217/205 217/205
2054 TD7893V 1 5.69 SP

2054 TD7893V 1 5.69 SP


PL-WPS-024
KP-08-FTJ-731 04.01.2019 150°C <250 217/205 217/205
2711 TD7715V 1 11.8 HB-45

2711 TD7715V 1 11.8 HB-45


PL-WPS-024
KP-08-FTJ-732 04.01.2019 150°C <250 217/205 217/205
2051 L3917V 1 11.86 HB-45

Legend: SP- Straight Pipe,HB-Horizontal Bend, SB-Sag Bend,OB-Over Bend R-Root Pass, H-Hot Pass ,F-Filling, C - Capping
1-Pipe (API 5L X 52), 2-ELBOW (A234 WPB), 3- TEE (A234 WPB), 4-FLANGE(A105N)
CONTRACTOR COMPA
NAME

SIGNATURE

DATE

RS-QA-F-FLM-007-Rev.A
E6010 - 2135058 &
E7010P1 - 2141385
ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017& ADCO SPEC 30.99.00.0041-2 Rev.0

Welders Date Of Visual


Remarks
Welding Inspection
C

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE
COMPANY
CONSTRUCTION OF FLOWLINES AND WELLHEAD
TIE-IN INSTALLATIONS AT ADCO’s FIELD (PACKAGE-"C")
(Project No:12335 & Contract No:16392.03 )
WELDING INSPECTION REPORT (PIPE LINE)
REPORT No: BQ 42-WIR-99 DATE: 1/4/2019 LOCATION : BQ 42
DRAWING No:12/78/07/0627/REV B CHAINAGE : FROM:08+500 TO:08+700
WELDING PROCESS: SMAW SERVICE : OIL Filler Metal Batch :
Pipe Dia & Thickness: 6" x 14.27 mm (API 5L GR.B) Accp Criteria: ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017&

Length of Type of Welders


Date of Fitup Pre-Heat Inter Pass
Pipe No. Heat No. Material Pipe in Bend - Weld No. WPS
Inspection Temp (°C) Temp (°C)
meters Degree
R&H F

2051 L3917V 1 11.86 HB-45


PL-WPS-024
KP-08-FTJ-733 04.01.2019 150°C <250 217/205 217/205
5142 TD7695V 1 11.8 SP

2130 TD7700V 1 11.8 SP


PL-WPS-023
KP-08-MJ-710 04.01.2019 Rev.2
110°C <220 217/205 217/205
2163 TD7738V 1 11.12 SP

4355 TD7741V 1 11.81 SP


PL-WPS-024
KP-08-FTJ-689 04.01.2019 150°C <250 217/205 217/205
2125 TD7700V 1 11.86 HB-45

2125 TD7700V 1 11.86 HB-45


PL-WPS-024
KP-08-FTJ-690 04.01.2019 150°C <250 217/205 217/205
4355 TD7741V 1 5.69 SP

4355 TD7741V 1 5.69 SP


PL-WPS-024
KP-08-FTJ-691 04.01.2019 150°C <250 217/205 217/205
3180 TD7722V 1 11.54 HB-45

3180 TD7722V 1 11.54 HB-45


PL-WPS-024
KP-08-FTJ-692 04.01.2019 150°C <250 217/205 217/205
4353 TD7741V 1 2.5 SP
Legend: SP- Straight Pipe,HB-Horizontal Bend, SB-Sag Bend,OB-Over Bend R-Root Pass, H-Hot Pass ,F-Filling, C - Capping
1-Pipe (API 5L X 52), 2-ELBOW (A234 WPB), 3- TEE (A234 WPB), 4-FLANGE(A105N)
CONTRACTOR COMPA
NAME

SIGNATURE

DATE

RS-QA-F-FLM-007-Rev.A
E6010 - 2135058 &
E7010P1 - 2141385
ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017& ADCO SPEC 30.99.00.0041-2 Rev.0

Welders Date Of Visual


Remarks
Welding Inspection
C

BARE
217/205 04.01.2019 ACC
BARE

COATED
217/205 04.01.2019 ACC
COATED

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE
COMPANY
CONSTRUCTION OF FLOWLINES AND WELLHEAD
TIE-IN INSTALLATIONS AT ADCO’s FIELD (PACKAGE-"C")
(Project No:12335 & Contract No:16392.03 )
WELDING INSPECTION REPORT (PIPE LINE)
REPORT No: BQ 42-WIR-100 DATE: 1/4/2019 LOCATION : BQ 42
DRAWING No:12/78/07/0627/REV B CHAINAGE : FROM:08+500 TO:08+700
WELDING PROCESS: SMAW SERVICE : OIL Filler Metal Batch :
Pipe Dia & Thickness: 6" x 14.27 mm (API 5L GR.B) Accp Criteria: ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017&

Length of Type of Welders


Date of Fitup Pre-Heat Inter Pass
Pipe No. Heat No. Material Pipe in Bend - Weld No. WPS
Inspection Temp (°C) Temp (°C)
meters Degree
R&H F

4353 TD7741V 1 2.5 SP


PL-WPS-024
KP-08-FTJ-693 04.01.2019 150°C <250 217/205 217/205
3181 TD7722V 1 11.86 HB-45

3181 TD7722V 1 11.86 HB-45


PL-WPS-024
KP-08-FTJ-694 04.01.2019 150°C <250 217/205 217/205
4136 TD7696V 1 8 SP

4136 TD7696V 1 8 SP
PL-WPS-024
KP-08-FTJ-694A 04.01.2019 150°C <250 217/205 217/205
4817 L2904V 1 11.86 HB-45

4817 L2904V 1 11.86 HB-45


PL-WPS-024
KP-08-FTJ-694A 04.01.2019 150°C <250 217/205 217/205
4356 TD7741V 1 11.82 HB-45

Legend: SP- Straight Pipe,HB-Horizontal Bend, SB-Sag Bend,OB-Over Bend R-Root Pass, H-Hot Pass ,F-Filling, C - Capping
1-Pipe (API 5L X 52), 2-ELBOW (A234 WPB), 3- TEE (A234 WPB), 4-FLANGE(A105N)
CONTRACTOR COMPA
NAME

SIGNATURE

DATE

RS-QA-F-FLM-007-Rev.A
E6010 - 2135058 &
E7010P1 - 2141385
ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017& ADCO SPEC 30.99.00.0041-2 Rev.0

Welders Date Of Visual


Remarks
Welding Inspection
C

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE

BARE
217/205 04.01.2019 ACC
BARE
COMPANY
CONSTRUCTION OF FLOWLINES AND WELLHEAD
TIE-IN INSTALLATIONS AT ADCO’s FIELD (PACKAGE-"C")
(Project No:12335 & Contract No:16392.03 )
WELDING INSPECTION REPORT (PIPE LINE)
REPORT No: BQ 42-WIR-101 DATE: 1/5/2019 LOCATION : BQ 42
DRAWING No:12/78/07/0627/REV B CHAINAGE : FROM:07+600 TO:07+640
WELDING PROCESS: SMAW SERVICE : OIL Filler Metal Batch :
Pipe Dia & Thickness: 6" x 14.27 mm (API 5L GR.B) Accp Criteria: ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017&

Length of Type of Welders


Date of Fitup Pre-Heat Inter Pass
Pipe No. Heat No. Material Pipe in Bend - Weld No. WPS
Inspection Temp (°C) Temp (°C)
meters Degree
R&H F

3276 TD7686V 1 SP
11.86 PL-WPS-023
KP-07-MJ-663 05.01.2019 Rev.2
110°C <220 217/205 217/205
3525 TD7686V 1 11.7 SP

3525 TD7686V 1 11.7 SP


PL-WPS-024
KP-07-FTJ-664 05.01.2019 150°C <250 217/205 217/205
3489 TD7686V 1 11.76 HB-45

3489 TD7686V 1 11.76 HB-45


PL-WPS-024
KP-07-FTJ-665 05.01.2019 150°C <250 217/205 217/205
2050 L2917V 1 11.86 HB-45

2050 L2917V 1 11.86 HB-45


PL-WPS-024
KP-07-FTJ-666 05.01.2019 150°C <250 217/205 217/205
3549 TD7686V 1 11.82 SP

1047 TD7721-V 1 11.86 SP


PL-WPS-024
KP-08-FTJ-615 05.01.2019 150°C <250 217/205 217/205
3542 TD7686V 1 11.82 HB-45

3542 TD7686V 1 11.82 HB-45


PL-WPS-024
KP-08-FTJ-616 05.01.2019 150°C <250 217/205 217/205
0945 TD7723V 1 11.86 HB-45
Legend: SP- Straight Pipe,HB-Horizontal Bend, SB-Sag Bend,OB-Over Bend R-Root Pass, H-Hot Pass ,F-Filling, C - Capping
1-Pipe (API 5L X 52), 2-ELBOW (A234 WPB), 3- TEE (A234 WPB), 4-FLANGE(A105N)
CONTRACTOR COMPA
NAME

SIGNATURE

DATE

RS-QA-F-FLM-007-Rev.A
E6010 - 2135058 &
E7010P1 - 2141385
ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017& ADCO SPEC 30.99.00.0041-2 Rev.0

Welders Date Of Visual


Remarks
Welding Inspection
C

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE
COMPANY
CONSTRUCTION OF FLOWLINES AND WELLHEAD
TIE-IN INSTALLATIONS AT ADCO’s FIELD (PACKAGE-"C")
(Project No:12335 & Contract No:16392.03 )
WELDING INSPECTION REPORT (PIPE LINE)
REPORT No: BQ 42-WIR-102 DATE: 1/5/2019 LOCATION : BQ 42
DRAWING No:12/78/07/0627/REV B CHAINAGE : FROM:07+600 TO:07+640
WELDING PROCESS: SMAW SERVICE : OIL Filler Metal Batch :
Pipe Dia & Thickness: 6" x 14.27 mm (API 5L GR.B) Accp Criteria: ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017&

Length of Type of Welders


Date of Fitup Pre-Heat Inter Pass
Pipe No. Heat No. Material Pipe in Bend - Weld No. WPS
Inspection Temp (°C) Temp (°C)
meters Degree
R&H F

0945 TD7723V 1 11.86 HB-45


PL-WPS-024
KP-07-FTJ-617 05.01.2019 150°C <250 217/205 217/205
0942 TD7723V 1 6.3 SP

0942 TD7723V 1 6.3 SP


PL-WPS-024
KP-07-FTJ-618 05.01.2019 150°C <250 217/205 217/205
1048 TD7721V 1 7 SP

1048 TD7721V 1 7 SP
PL-WPS-024
KP-07-FTJ-619 05.01.2019 150°C <250 217/205 217/205
2717 TD7715V 1 11.88 HB-45

2717 TD7715V 1 11.88 HB-45


PL-WPS-024
KP-07-FTJ-620 05.01.2019 150°C <250 217/205 217/205
3179 TD7722V 1 11.75 HB-45

3179 TD7722V 1 11.75 HB-45


PL-WPS-024
KP-07-FTJ-621 05.01.2019 150°C <250 217/205 217/205
1206 L2903V 1 11.86 SP
KP 07 622 DELETED
Legend: SP- Straight Pipe,HB-Horizontal Bend, SB-Sag Bend,OB-Over Bend R-Root Pass, H-Hot Pass ,F-Filling, C - Capping
1-Pipe (API 5L X 52), 2-ELBOW (A234 WPB), 3- TEE (A234 WPB), 4-FLANGE(A105N)
CONTRACTOR COMPA
NAME

SIGNATURE

DATE

RS-QA-F-FLM-007-Rev.A
E6010 - 2135058 &
E7010P1 - 2141385
ISO 13847:2013, DEP 61.40.20.30 GEN FEB 2017& ADCO SPEC 30.99.00.0041-2 Rev.0

Welders Date Of Visual


Remarks
Welding Inspection
C

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE

BARE
217/205 05.01.2019 ACC
BARE
622 DELETED
COMPANY