You are on page 1of 42

Quick Selection Guide, Asia Pacific

Circuit Protection &


Control Products
Energizing a world
that demands more.
We deliver:
• Electrical solutions that use less energy, improve power reliability and make the
places we live and work safer and more comfortable
• Hydraulic and electrical solutions that enable machines to deliver more
productivity without wasting power
• Aerospace solutions that make aircraft lighter, safer and less costly to operate,
and help airports operate more efficiently
• Vehicle drivetrain and powertrain solutions that deliver more power to cars,
trucks and buses, while reducing fuel consumption and emissions

Discover today’s Eaton.

Powering business worldwide


As a global diversifi ed power management We provide integrated solutions that help make
company, we help customers worldwide manage energy, in all its forms, more practical and acces-
the power needed for buildings, aircraft, trucks, sible.
cars, machinery and businesses.
With 2013 sales of $20.0 billion, Eaton has
Eaton’s innovative technologies help customers approximately 100,000 employees around the
manage electrical, hydraulic and mechanical world and sells products in more than 175
power more reliably, effi ciently, safely and countries.
sustainably.
Circuit Protection & Control Products Quick Selection Guide
Contents

Circuit Protection & Eaton Circuit Protection & Control Product Family
Control Products Low Voltage Circuit Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Industrial Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Low Voltage Circuit Protection


Air Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Molded Case Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Miniature Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Industrial Control
Motor Start & Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Command Control & Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Industrial Automation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

1
Circuit Protection & Control Products Quick Selection Guide
Product Family Snapshot

Low Voltage Circuit Protection

IZMX Series Air Circuit Breakers NZM Series Molded Case Circuit Breakers LZM Series Molded Case Circuit Breakers

Industrial Control

Adjustable Frequency Drives Control Relay EASY EASY Safety Control Relay ES4P

Soft Start Controllers SmartWire-DT® XC PLC

M22 Pushbuttons and Indicating Lights Position Switches LS

2
Circuit Protection & Control Products Quick Selection Guide
Product Family Snapshot

BZM Series Molded Case Circuit Breakers Miniature Circuit Breaker Surge Protection Device Automatic Transfer Switches

Touch Display/PLC Motor Protective Circuit Breaker XTCG Contactor Foot and Palm Switches FAK

XION Remote I/O Module Motor Control and Protection T Cam Switches

Signal Towers SL Relays Electronic Timing Relay DIL ET

3
4
Circuit Protection & Control Products Quick Selection Guide
Air Circuit Breaker

IZMX Series IZMX Series

IZMX 16 B 4 - V 16 W

Product Type Mounting Form


IZMX = Air circuit breaker W = Withdrawable
INX = Switch disconnector F = Fixed

Frame Size Rated Current


16 = 630A-1600A IZMX16
40 = 800A-4000A 06 = 600A 08 = 800A 10 = 1000A
12 = 1250A 16 = 1600A
Switching Capacity IZMX40
Poles
E = Economy: (IZMX40E:66kA@440VAC) 08 = 800A 10 = 1000A 12 = 1250A
3 = 3 pole 16 = 1600A 20 = 2000A 25 = 2500A
B = Basic: (IZMX16B:42kA, IZMX40B:66kA)
4 = 4 pole 32 = 3200A 40 = 4000A
N = Normal: (IZMX16N:50kA, IZMX40B:85kA)
H = High: (IZMX16H:66kA, IZMX40H:105kA) E type: 800~2000A only

Trip Unit Type


V = Selective-current
U = Universal-power
P = Professional

Recommended Selection Examples


IZMX16 fixed 220VAC motorized example: IZMX16 withdrawable 220VAC motorized example:
IZMX16B3-V16F Fixed breaker, including 2a2b Aux contact IZMX16B3-U16W Withdrawable parent breaker, including 2a2b Aux contact
+IZMX-M16-230AD 220-240 VAC/DC Charging motor +IZMX-M16-230AD 220-240 VAC/DC Charging motor
+IZMX-ST230AD 220-240 VAC/DC Shunt trip +IZMX-ST230AD 220-240 VAC/DC Shunt trip
+IZMX-SR230AD 220-240 VAC/DC Closing spring release +IZMX-SR230AD 220-240 VAC/DC Closing spring release
+IZMX-AS22 Additional 2a2b Aux contact (4a4b total) +IZMX-AS22 Additional 2a2b Aux contact (4a4b total)
+IZMX-OTS Over current trip switch(OTS) 2CO +IZMX-OTS Over current trip switch(OTS) 2CO
IZMX-THV163 Main terminal adapter - horizontal +IZMX-CAS163-1600 Cassette(including interphase barriers and handle)
EASY400-POW External power module to converter 220VAC to +IZMX-SH163 Safety shutters
24VDC to power trip unit IZMX-THV163 Main terminal adapter - horizontal
EASY400-POW External power module to converter 220VAC to 24VDC to
power trip unit
IZMX40 fixed 220VAC motorized example: IZMX40 withdrawable 220VAC motorized example:
IZMX40B3-V16F Fixed parent breaker, including 2a2b Aux contact IZMX40B3-U16W Withdrawable parent breaker, including 2a2b Aux contact
+IZMX-M40-230AD 220-240 VAC/DC Charging motor +IZMX-M40-230AD 220-240 VAC/DC Charging motor
+IZMX-ST230AD 220-240 VAC/DC Shunt trip +IZMX-ST230AD 220-240 VAC/DC Shunt trip
+IZMX-SR230AD 220-240 VAC/DC Closing spring release +IZMX-SR230AD 220-240 VAC/DC Closing spring release
+IZMX-AS22 Additional 2a2b Aux contact (4a4b total) +IZMX-AS22 Additional 2a2b Aux contact (4a4b total)
+IZMX-OTS Over current trip switch(OTS) 2CO +IZMX-OTS Over current trip switch(OTS) 2CO
IZMX-THV403-3200 Main terminal adapter – horizontal (3200A and below) +IZMX-CAS403-2000 Cassette(2000A and below)
EASY400-POW External power module to converter 220VAC to 24VDC +IZMX-SH403 Safety shutters
to power trip unit IZMX-THV403-3200 Main terminal adapter – horizontal (3200A and below)
EASY400-POW External power module to converter 220VAC to 24VDC to
power trip unit

Option for ground fault protection:


• Add +IZMX-PXRV-G (V type trip unit) or +IZMX-PXRU-G(U type trip unit) for ground fault protection
• For 3-pole ACB, external neutral censor is recommended for ground fault protection. Order IZMX-CT16-N(IZMX16) or IZMX-CT40-N(IZMX40)

5
Circuit Protection & Control Products Quick Selection Guide
Air Circuit Breaker

IZMX system overview

IZMX16 IZMX40
10
3

11 15

2
13 14
22

12

22

16
17
8
1
15
18

19

21
20

23
24

20
5
6
7
9

Unique parts and accessories for -IZMX16 Interchangeable accessories between


IZMX16 and IZMX40

6
Circuit Protection & Control Products Quick Selection Guide
Air Circuit Breaker

IZMX16, INX16, IZMX40, INX40 1 IZMX Circuit-breaker 12 Latch check switch


IZMX16: 630 - 1600A For external application
IZMX40: 800 - 4000A Usage
+IZMX-LCS
2 Cassette for withdrawable units
+IZMX-CAS163-1600 X16, 1600A, 3P 13 Latch check switch
+IZMX-CAS164-1600 X16, 1600A, 4P For use with closing release.
3 +IZMX-CAS403-2000 X40, 2000A, 3P +IZMX-LCS-SR
+IZMX-CAS404-2000 X40, 2000A, 4P
+IZMX-CAS403-2500 X40, 2500A, 3P 14 Closing releases
+IZMX-CAS404-2500 X40, 2500A, 4P Closes the breaker by an electrical
+IZMX-CAS403-3200 X40, 3200A, 3P signal.
3 +IZMX-CAS404-3200 X40, 3200A, 4P +IZMX-SR24DC 24VDC
3
+IZMX-CAS403-4000 X40, 4000A, 3P +IZMX-SR110AD 110AC/DC
2 +IZMX-CAS404-4000 X40, 4000A, 4P +IZMX-SR230AD 220AC/DC
15 Key locking
3 Main terminal kits
Locking of the breaker by a keylock.
Universal terminals, 3- and 4-pole
IZMX-KLP-SO-CES
horizontal/vertical
IZMX-KLP-SO-KIRK
IZMX-THV163 X16, 3P
IZMX-KLP-SO-RONIS
IZMX-THV164 X16, 4P
IZMX-KLP-SO-CASTELL
IZMX-THV403-3200 X40, 3P, 3200A
IZMX-THV404-3200 X40, 4P, 3200A 16 Shunt releases
IZMX-TH403 X40, 3P, 4000A, horizontal Opens the breaker by an electrical
IZMX-TV403 X40, 3P, 4000A, vertical signal.
IZMX-TH404 X40, 4P, 4000A, horizontal +IZMX-ST24DC 24VDC
IZMX-TV404 X40, 4P, 4000A, vertical +IZMX-ST110AD 110VAC/DC
+IZMX-ST230AD 220VAC/DC
4 Safety Shutter
1 +IZMX-SH163 X16, 3P 17 Undervoltage releases
+IZMX-SH164 X16, 4P Opens the breaker by a voltage-drop
+IZMX-SH403 X40, 3P in the control circuit.
+IZMX-SH404 X40, 4P +IZMX-UVR24DC 24VDC
+IZMX-UVR110AD 110VAC/DC
5 Motor operator +IZMX-UVR220AD 220VAC/DC
Automatic charging of the spring force +IZMX-UVR400AC 380VAC
storage for remote or local operations
+IZMX-M16-24DC X16, 24VDC 18 Red-pop trip indicator
+IZMX-M16-110AD X16, 110VAC/DC Red-pop trip indicator signals a trip
+IZMX-M16-230AD X16, 220VAC/DC by the trip unit
+IZMX-M40-24DC X40, 24VDC Included in breaker with trip unit
+IZMX-M40-110AD X40, 110VAC/DC
+IZMX-M40-230AD X40, 110VAC/DC 19 Trip indicator switches
Overcurrent trip switch (OTS) signals
6 Current sensor for neutral a trip by the trip unit.
conductor +IZMX-OTS
Current sensor for sensing the
4 20 Switching operations counters
neutral-conductor current.
IZMX-CT16-N X16 Counts the number of operations.
IZMX-CT40-N X40 +IZMX-OC
21 Auxiliary contacts
7 Levering tool Signaling switch ON-OFF.
Convenient collapsible lev-in tool for 2a2b standard. 4a4b maximum for
lev-in and out operation of the Breaker IZMX16 and 12a12b for IZMX40
in and out of the Cassette. The lev-in +IZMX-AS22 X16/X40, add 2a2b
tool is stored inside the breaker. +IZMX-AS44 X40, add 4a4b
Included in D/O breaker order +IZMX-AS66 X40, add 6a6b
9
+IZMX-AS88 X40, add 8a8b
8 Position cell switches +IZMX-AS1010 X40, add 10a10b
Cell switch signals the position of the
breaker inside of the cassette. 22 Locking facilities
6 Connect, Test and Disconnect Position. Plastic or metal
IZMX-CS16-1 X16 IZMX-PLPC16-P X16, plastic
IZMX-CS40-L X40, left IZMX-PLPC16-M X16, metal
IZMX-CS40-R X40, right IZMX-PLPC40-P X40, plastic
5 IZMX-PLPC40-M X40, metal
9 Door escutcheon
Closes the gap between Breaker and 23 Trip unit
Switchgear-door. PXR20, V-type, current metering
IP41 included in breaker C - Onboard Modbus
For IP55: G - Ground fault protection
IZMX-DC16-W X16 M - Arcflash Reduction Maintenance
IZMX-DC40-W X40 System™
+IZMX-PXRV-C
10 Communication modules +IZMX-PXRV-G
Unique parts and accessories for IZMX40 External modules +IZMX-PXRV-GC
IZMX-MCAM Modbus +IZMX-PXRV-GM
IZMX-ECAM Ethernet +IZMX-PXRV-GMC
IZMX-PCAM Profibus DP
24 Trip unit
11 Control circuit terminal units PXR25, U-type, power metering
Modular design +IZMX-PXRU-G
+IZMX-PXRU-M
+IZMX-PXRU-GM

7
Circuit Protection & Control Products Quick Selection Guide
Air Circuit Breaker

IZM Series NES Type*

N E S6 08 3 W 52 8 R T R N 4 5 N 4 X
Breaker Frame Size
N = Type NF, 630–1600A,

Standard, Mechanism, Device


E = IEC 60947-2

Fault Current Rating Future Use


S4 = 42 kA at 415 Vac IEC X = All product
S5 = 50 kA at 415 Vac IEC
S6 = 65 kA at 415 Vac IEC
UVR, Second Shunt Trip Drawout Breaker Shipping,
N = None Fixed Breaker Terminals
Frame Rating (Amperes) (Door Frame Kit ships as
A = 110–125 Vac/Vdc UVR
07 = 630 R = 220–250 Vac/Vdc UVR standard unless noted
08 = 800 L = 24 Vdc UVR otherwise)
10 = 1000 H = 48 Vdc UVR
13 = 1250 S = 60 Vdc UVR D = Drawout (or parent) breaker
16 = 1600 G = 32 Vdc UVR shipping alone, without door
1 = 110–127 Vac/Vdc second shunt trip frame kit
2 = 208–240 Vac/Vdc second shunt trip 4 = Drawout breaker in cassette,
Poles, Phasing 4 = 24 Vdc second shunt trip with shutters, short vertical/
3 = Three-pole, ABC 8 = 48 Vdc second shunt trip horizontal
4 = Four-pole, NABC F = Fixed terminal adapters for
Spring Release, rear connect, with mounting
Mounting Configuration Latch Check Switch feet, short vertical/
W = Drawout horizontal
N = No spring release, no LCS
B = Fixed mount rear connect, mounting bracket, E = No spring release, LCS wired external
with secondary terminal row A = 110–127 Vac/Vdc, no LCS
B = 110–127 Vac/Vdc, spring release LCS
C = 110–127 Vac/Vdc, LCS wired external
Trip Unit, Power Supply
R = 208–240 Vac/Vdc, no LCS
SW = Switch—no MCR—42 kA for IEC S = 208–240 Vac/Vdc, spring release LCS
22 = 520 LI, no ZSI T = 208–240 Vac/Vdc, LCS wired external
52 = 520 LSI, no ZSI L = 24 Vdc, no LCS
53 = 520 LSI, with ZSI P = 24 Vdc, spring release LCS
5G = 520 LSIG, no ZSI Q = 24 Vdc, LCS wired external
5H = 520 LSIG, with ZSI H = 48 Vdc, no LCS
M2 = 520M LSI, no ZSI, 24 Vdc J = 48 Vdc, spring release LCS
M3 = 520M LSI, with ZSI, 24 Vdc K = 48 Vdc, LCS wired external
MA = 520M LSIA, no ZSI, 24 Vdc
MB = 520M LSIA, with ZSI, 24 Vdc
MG = 520M LSIG, no ZSI, 24 Vdc Motor Operator
MH = 520M LSIG, with ZSI, 24 Vdc M = Manually operated Auxiliary, Switches,
R2 = 520M LSI, no ZSI, 24 Vdc, with ARMS B = 110–125 Vac/dc Label Language
R3 = 520M LSI, with ZSI, 24 Vdc, with ARMS T = 208–250 Vac/dc E = No auxiliary switches,
RA = 520M LSIA, no ZSI, 24 Vdc, with ARMS L = 24 Vdc no label (parent)
RB = 520M LSIA, with ZSI, 24 Vdc, with ARMS H = 48 Vdc 4 = 4 Form C, English
RG = 520M LSIG, no ZSI, 24 Vdc, with ARMS
RH = 520M LSIG, with ZSI, 24 Vdc, with ARMS
Trip Indicator OTS Secondary
Rating Plug(Amperes) and Bell Alarm Terminal Blocks
1 = 200 5 = 500 A = 1000 N None None Per breaker options 2
2 = 250 7 = 630 C = 1250 5 Interlock trip indicator 2 Form C Full complement 2
4 = 400 8 = 800 D = 1600
Padlock Key Lock Operations
Provisions Provisions Counter
Shunt Trip
N No None No
N = No shunt trip A No — Provided
A = 110–127 Vac/Vdc B Yes (plastic/plastic) — No
R = 208–240 Vac/Vdc C Yes (plastic/plastic) — Provided
L = 24 Vdc
H = 48 Vdc

* IZM series NES type air circuit breaker will be phased-out by Dec 31st 2015 and be replaced by IZMX series"

8
Circuit Protection & Control Products Quick Selection Guide
Air Circuit Breaker

IZM Series MWI Type*

MW I 8 12 4 L E A - 12 MT R P R N 4 L N N N W X

Breaker Frame Future Use


I = Standard X = All ACBs
or double
ACB Shipping Instructions
Interrupting Icu A = Fixed ACB with door kit
6 = 65 kA A = D/O ACB only without
8 = 85 kA door kit
C = 100 kA Trip Unit and Protection, W = D/O ACB in cassette
(and External Control (pre-wired and shutters)
Voltage When Required) Double frame D/O ACBs ship
Continuous Amperes Shunt Trip
NN = Non-automatic (no trip unit) without cassette
and Phasing (Facing Attachment (STA)
22 = 520 LI
Front of Breaker)
52 = 520 LSI N = None
08 = 800 ABC 5W = 520i LSIG A = 110–127 Vac/Vdc Latch Check Switch/Trip Unit
10 = 1000 ABC MT = 520M LSI (24–48 Vdc) R = 208–240 Vac/Vdc Metering Voltage Connection
12 = 1250 ABC MU = 520M LSI (120 Vac) C = 24 Vdc for Digitrip 1150 Trip Unit
16 = 1600 ABC MV = 520M LSI (240 Vac) H = 48 Vdc Latch Check 1150 Voltage
20 = 2000 ABC MJ = 520Mi LSIG (24–48 Vdc) B = 110–127 Vac/Vdc Switch Connection
25 = 2500 ABC MK = 520Mi LSIG (120 Vac) (100% duty) N = None Upper terminals
32 = 3200 ABC ML = 520Mi LSIG (240 Vac) S = 220–250 Vac/Vdc L = LCS wired to SRD Upper terminals
41 = 4000 ABC (standard ME = 520M LSIA (24–48 Vdc) (100% duty) C = LCS wired external Upper terminals
drawout only) MC = 520M LSIA (120 Vac) D = 24 Vdc (100% duty)
4N = 4000 AABBCC MF = 520M LSIA (240 Vac) K = 48 Vdc (100% duty)
5N = 5000 AABBCC CT = 520MC LSI (24–48 Vdc) Operations Counter and/or
6N = 6300 AABBCC CU = 520MC LSI (120 Vac) Keylock Provisions
CV = 520MC LSI (240 Vac) Motor Operator
Counter Keylock
CE = 520MC LSIA (24–48 Vdc) M = Manual operated Provisions
Poles and Neutral CC = 520MC LSIA (120 Vac) N = 110–125 Vac (5-sec)
(Facing Front of Breaker) CF = 520MC LSIA (240 Vac) N = No counter No locks
W = 110–125 Vdc (5-sec)
3 = Three CJ = 520MCi LSIG (24–48 Vdc) K = No counter Kirk lock
T = 220–250 Vdc (5-sec)
4 = Four (neutral left) C = No counter Castell lock
CK = 520MCi LSIG (120 Vac) P = 220–240 Vac (5-sec)
R = No counter Ronis lock
CL = 520MCi LSIG (240 Vac) L = 24 Vdc (5-sec)
A = Counter No lock
C1 = 520MC ARMS LSI (24–48 Vdc) K = 48 Vdc (5-sec)
Mounting Configuration Y = Counter Kirk lock
C2 = 520MC ARMS LSI (120 Vac)
and Load Terminals L = Counter Castell lock
C3 = 520MC ARMS LSI (240 Vac) Spring Release
H = Fixed horizontal H = Counter Ronis lock
C4 = 520MC ARMS LSIA (24–48 Vdc) Device (SRD)
V = Fixed vertical C5 = 520MC ARMS LSIA (120 Vac)
L = Drawout horizontal C6 = 520MC ARMS LSIA (240 Vac) N = None
C7 = 520MC ARMS LSIG (24–48 Vdc) A = 110–127 Vac/Vdc Padlock Provisions for Blocking Close
C8 = 520MC ARMS LSIG (120 Vac) R = 208–240 Vac/Vdc and/or Open ACB Manual Pushbuttons
Nameplate Language C = 24 Vdc
C9 = 520MC ARMS LSIG (240 Vac) N = None
E = English H = 48 Vdc P = Plastic (block close and open)
1W = 1150i LSI (24–48 Vdc)
1N = 1150i LSI (120 Vac)
Sensor and Rating Plug Rating 1P = 1150i LSI (240 Vac) Undervoltage Release (UVR) or
1R = 1150i LSIG/A (24–48 Vdc) 2nd Shunt Trip (ST) Bell Alarms Switch (OTS) with 2a/2b
NN = None 16 = 1600 Contacts and/or Mechanical Trip Indicator
02 = 200 20 = 2000 1S = 1150i LSIG/A (120 Vac) N = None
1T = 1150i LSIG/A (240 Vac) A = UVR (110–127 Vac) OTS 2a/2b Trip Indicator
05 = 250 25 = 2500
04 = 400 12 = 1150i ARMS LSI (24-48 Vdc) R = UVR (208–240 Vac) E = No OTS No indicator 2
32 = 3200
13 = 1150i ARMS LSI (120 Vac) C = UVR (24 Vdc) L = With OTS With interlocked indicator
07 = 630 40 = 4000
08 = 800 14 = 1150i ARMS LSI (240 Vac) H = UVR (48 Vdc)
50 = 5000
10 = 1000 15 = 1150i ARMS LSI (125 Vdc) E = UVR (110–125 Vdc)
63 = 6300
13 = 1250 16 = 1150i ARMS LSIG/A (24-48 Vdc) F = UVR (220–250 Vdc) Auxiliary Switch
17 = 1150i ARMS LSIG/A (120 Vac) G = UVR (32 Vdc) N = None
18 = 1150i ARMS LSIG/A (240 Vac) X = UVR (380–415 Vac) 4 = 4A/4B
19 = 1150i ARMS LSIG/A (125 Vdc) J = UVR (480 Vac) 6 = 6A/6B
K = UVR (600 Vac)
1 = 2nd ST (110–127 Vac/Vdc)
2 = 2nd ST (208–250 Vac/Vdc)
3 = 2nd ST (24 Vdc)
4 = 2nd ST (48 Vdc)
B = 2nd ST (110–127 Vac/Vdc
100% duty)
O = 2nd ST (220–250 Vac/Vdc
100% duty)
I = 2nd ST (24 Vdc 100% duty)
Q = 2nd ST (48 Vdc 100% duty)

* IZM series MWI type air circuit breaker will be phased-out by Dec 31st 2015 and be replaced by IZMX series"

Note
1 Exclusionary rules apply. Refer to price list. Confirm all final part numbers with Eaton. Format structure subject to modifications and additions without notice.
2 Position 20, ACB (with digitrip) must choose”L”, switch-disconnector must choose”E”.

9
Circuit Protection & Control Products Quick Selection Guide
Molded Case Circuit Breaker

NZM Series NZM Series Molded Case Circuit Breaker

NZM B 2 - 4 - A 200

Designation Ampere Rating


NZM = Circuit breaker 20A-1600A
N = Disconnector, with trip
PN = Disconnector, without trip Trip Unit
A = Thermomagnetic system protection
Breaking Capacity AE = Electronic system protection
B = 25 kA M = Thermomagnetic motor protection
C = 36 kA ME = Electronic motor protection
N = 50 kA S = Motor protection without overload release
S = 70 kA Frame Size VE = Electronic selective system protection
H = 85,100,150 kA 1 = 20A-160A
2 = 125A-250A
Poles
3 = 400A-630A
4 = 630A-1600A Blank = 3 Pole
4 = 4 Pole

LZM Series LZM Series Molded Case Circuit Breaker

LZM B 2 - 4 - A 200

Designation Ampere Rating


LZM = Circuit breaker 20A-630A

Breaking Capacity Trip Unit


B = 25 kA A = Thermomagnetic system protection
C = 36 kA AE = Electronic system protection
N = 50 kA S = Motor protection without overload release
S = 70 kA VE = Electronic selective system protection
Frame Size
1 = 20A-160A Poles
2 = 125A-250A
3 = 250A-630A Blank = 3 Pole
4 = 4 Pole

10
Circuit Protection & Control Products Quick Selection Guide
Molded Case Circuit Breakers / Miniature Circuit Breakers

BZM Series BZM Series Molded Case Circuit Breaker

BZM B 1 - A16 - BT

Designation Terminal
BZM = Circuit breaker used for building Blank = Cable terminal
BT = Box terminal

Breaking Capacity
E = 18 kA (Only for Frame 1) Ampere Rating
B = 25 kA
16A-400A
C = 36 kA
N = 50 kA (Only for Frame 3)

Frame Size
1 = 16A-125A
2 = 125A-250A
3 = 250A-400A

FAZ Miniature Circuit Breaker FAZ Miniature Circuit Breaker

FAZ - C 6 / 2 -NA -DC

Designation
FAZ = MCB (10/15kA rated
breaking capacity) AC/DC
Blank = AC
-DC = DC
Tripping Characteristic
B = B curve
Standard
C = C curve
D = D curve Blank = IEC standard
K = K curve Ampere Rating -NA = UL489 based, lift terminal
Poles
S = S curve 0.16~63A -RT = UL489 based, ring-tongue
1 = 1P terminal
Z = Z curve 2 = 2P
3 = 3P
4 = 4P
1N = 1P+N
3N = 3P+N

11
Circuit Protection & Control Products Quick Selection Guide
Miniature Circuit Breakers

Xpole Miniature Circuit Breaker Xpole Miniature Circuit Breaker

PL S6 - C 40 /2 -DC -AS

Designation
PL = Xpole MCB
Regional Version
Blank = Global
Rated Breaking Capacity
-AS = Asia
S6 = 6kA
SM = 10kA
AC/DC
N6 = 6kA (1P+N, 1 MU width) Ampere Rating
Z6 = 6kA (1P+N, 1.5 MU width) Blank = AC
0.5-63A -DC = DC
ZM = 10kA (1P+N, 1.5 MU width)
HT = 15-25kA (high-rating MCB)
Poles
Tripping Characteristic /1 = 1 Pole
/2 = 2 Pole
B = B curve
/3 = 3 Pole
C = C curve
/4 = 4 Pole
D = D curve /1N = 1 Pole + Neutral
/3N = 3 Pole + Neutral

Xpole Residual Current Device (RCCB) Xpole Residual Current Device (RCCB)

PFIM - 100 / 2 / 01 -A -AS

Regional Version
Blank = Global
-AS = Asia

Designation
PFIM = Up to 100A RCD Type
PFDM = 125A Blank = AC type, no delay
-A = A type, no delay
-G = Minimum 10ms delay, 3kA surge current proof
Ampere Rating -G/A = A type, minimum 10ms delay, 3kA surge current proof
PFIM: 16-100 -S = Minimum 40ms delay, selective, 5kA surge current proof
PFDM: 125 -S/A = A Type, selective, minimum 40ms delay, 5kA surge current proof

Poles Fault Current


2 = 2 pole 001 = 10mA
4 = 4 pole 003 = 30mA
01 = 100mA
03 = 300mA
05 = 500mA

12
Circuit Protection & Control Products Quick Selection Guide
Miniature Circuit Breakers

Xpole Residual Current Device (RCBO) Xpole Residual Current Device (RCBO)

PKNM - 40 / 1N / C / 01 -A -AS

Designation
PFL10 = 10kA, 1P+N, ELM type
PFL9 = 6kA, 1P+N, ELM type Regional Version
PLD10 = 10kA, 1P+N, ELN type Blank = Global
Poles
PLD9 = 6kA, 1P+N, ELN type -AS = Asia
1N = 1P+N
PKNM = 10kA, 1P+N, ELM type
eRB6 = 6kA, 1P+N(18mm width), ELN type RCD Type
eRBM = 10kA, 1P+N(18mm width), ELN type Blank = AC type, no delay
ED6 = 6kA, 1P+N, ELN type Tripping Characteristic -A = A type, no delay
B = B curve
Ampere Rating C = C curve
Fault Current
D = D curve
2-45A 001 = 10mA
003 = 30mA
01 = 100mA
03 = 300mA

Xpole Residual Current Device (RCD) Xpole Residual Current Device (RCD)

PBSM - 40 4 / 003 -A

Designation
PBSM = ELM type, 2/3/4 poles, 40/63A
PBHT = ELM type, 2/4 poles, 80/125A RCD Type
PDB = ELN type, 2/3/4 poles, 40/63A
Blank = AC type, no delay
EDB = ELN type, 2/3/4 poles, 40/63A
-A = A type, no delay
EB6 = ELM type, 2/3/4 poles, 40/63A -G = Minimum 10ms delay, 3kA surge current proof
-S = Minimum 40ms delay, selective, 5kA surge current proof
-S/A = A Type, selective, minimum 40ms delay, 5kA surge current proof
Ampere Rating
40, 63, 80, 125
Fault Current
Poles 003 = 30mA
2 = 2 pole 01 = 100mA
3 = 3 pole 03 = 300mA
4 = 4 pole 05 = 500mA
1 = 1000mA

13
Circuit Protection & Control Products Quick Selection Guide
Miniature Circuit Breakers

Xpole Main Load Disconnector Xpole Main Load Disconnector Switch (Isolator)
Switch (Isolator)
IS - 40 / 1

Designation
IS = Isolator

Poles
1 = 1 pole
2 = 2 pole
Ampere Rating 3 = 3 pole
16, 20, 25, 32, 40, 63, 80, 100, 125A 4 = 4 pole

Xpole Z-R Installation Relay Xpole Z-R Installation Relay

Z - R230 / S

Designation
Z = Installation relay
Auxiliary Contact
S = 1NO
Control Voltage O = 1NC
AC DC SS = 2NO
R12 = 12 Vac R11 = 12 Vdc SO = 2NC
R24 = 24 Vac R23 = 23 Vdc OO = 2NC
R48 = 48 Vac R109 = 110 Vdc 2S2O = 2NO + 2NC
R110 = 110 Vac 3S1O = 3NO + 1NC
R230 = 230 Vac

14
Circuit Protection & Control Products Quick Selection Guide
Miniature Circuit Breakers / Surge Protection Device

Xpole Z-SCH Installation Contactor Xpole Z-SCH Installation Contactor

Z-SCH - 230 / 25 - 40

Auxiliary Contact
40 = 4NO
Designation 04 = 4NC
Z-SCH = Installation contactor 31 = 3NO + 1NC
22 = 2NO + 2NC
20 = 2NO
Control Voltage
24 = 24 Vac
230 = 230 Vac
Ampere Rating
25, 40, 63A

Surge Protection Device (SPD)—SPI Surge Protection Device (SPD)—SPI

SPI - 35 / 440 /3

Designation + Class Poles


Blank = 1P
SP = Surge protection
/3 = 3P
I = IEC Class I (former Class B)

Maximum Continuous Operating Voltage Uc (Vac)


Impulse Current Iimp (10/350) µs
440 = 440Vac
35 = 35kA
NPE = NPE module, 260Vac
50 = 50kA
100 = 100kA

15
Circuit Protection & Control Products Quick Selection Guide
Surge Protection Device

Surge Protection Device (SPD)— Surge Protection Device (SPD)—SPB/SPC/SPD/SPE


SPB/SPC/SPD/SPE
SP BT12 - 280 -3+NPE /BB

Designation
SP = Surge protection
Whether Supplied With Busbar
Blank = No busbar
Class
/BB = Supplied with busbar
BT12 = I+II combined type (12.5kA 10/350µs)
CT2 = Class II(20kA 8/20µs)
ET2 = Class II(10kA 8/20µs)
DT3 = Class III Poles
Blank = Insert module
/1 = 1P
Maximum Continuous Operating Voltage Uc (Vac)
/2 = 2P
BT12: 280 /3 = 3P
CT2: 75, 135, 175, 280, 335, 385, 460, 580 /4 = 4P
ET2: 280, 335 -1+NPE = 1P+N
DT3: 280, 335 -3+NPE = 3P+N

NSP Series SPD NSP Series Surge Protection Device

NSP 30 M 4 385 TNS R

Designation Remote Signaling


NSP = New surge protection device Blank = None
R = With remote signaling
Module Number
Nominal Discharge Current (8/20) µs In Blank = Insert module System Power Type
20 = In:20kA, Imax: 40kA 1 = 1P IEC = Single module
30 = In:30kA, Imax: 60kA 2 = 2P or 1P+N TN = TN system (2P)
40 = In:40kA, Imax: 80kA 3 = 3P TNC = TNC system (3P)
60 = In:60kA, Imax: 120kA 4 = 4P or 3P+N
TNS = TNS system (4P)
TT = TT system (1P+N or 3P+N)
Technology Type
M = MOV Maximum Continuous Operating Voltage Uc (Vac)
S = Dual-MOV or Spark-gap 385 = 385Vac
G = Gas discharge tube
H = Hybrid type

16
Circuit Protection & Control Products Quick Selection Guide
Automatic Transfer Switch

MATS Series ATS MATS Automatic Transfer Switch (MCB based)

MATS A 9 / C 32 4 CB

Designation CB
MATS CB = Circuit protection

Controller Poles
A = Basic 2 = 2 Pole
3 = 3 Pole
4 = 4 Pole
Inm
PL9 = 63A
Trip Curve Amperes
C type; D type 0.5~63

MCB Selection Guide


• Breaker: PL9, 6kA;
• Trip curve: C type or D type;
• Amperes: 0.5, 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63A;
• Controller: A type only.

MATS Automatic Transfer Switch (MCCB based)

MATS A C 1 / A 80 4 CB
Designation CB
MATS CB = Circuit protection

Controller Poles
A = Basic 3 = 3 Pole
B = Generator 4 = 4 Pole
C = Intelligence

Amperes
Break Capability 80
C = 36kA
N = 50kA
S = 70kA Trip Unite
A, AE
Inm
1 = 100-160A
2 = 160-250A
3 = 630A

MCB Selection Guide


• Controller: A, B, C;
• Break: LZM;
• Inm: 1: 160A, 2: 250A, 3: 630A;
• Break capability: C-36kA, N-50kA, S-70kA;
• Protective unite: A: Thermomagnetic trip;
AE: Electronic tripping device;
• Amperes: 1: 20, 25, 32, 40, 50, 63, 80, 100, 125, 160A;
2: 160, 200, 250A;
3: 320, 400, 500, 630A.

17
Circuit Protection & Control Products Quick Selection Guide
Automatic Transfer Switch

MATS Series Automatic Transfer MATS Series Automatic Transfer Switch (Disconnect based)
Switch (Disconnect based)
MATS G 400 / 3

Type Poles
MATS = Automatic 3 = 3 Pole
transfer switch Switch Current 4 = 4 Pole
G = Disconnect switch 16 = 16 A 160 = 160 A
20 = 20 A 180 = 180 A
25 = 25 A 200 = 200 A
32 = 32 A 225 = 225 A
40 = 40 A 250 = 250 A
50 = 50 A 315 = 315 A
63 = 63 A 350 = 350 A
80 = 80 A 400 = 400 A
100 = 100 A 500 = 500 A
125 = 125 A 630 = 630 A

18
Circuit Protection & Control Products Quick Selection Guide
Automatic Transfer Switch

Contactor-based Automatic Contactor-based Automatic Transfer Switch


Transfer Switch
AT C 3 C2 X 3 0400 X S U

Certification
Type
U = UL listed
AT = Automatic R = UL recognized
BI = Bypass
Mechanism
isolation
open C1 = Closed
Amperes Voltage Enclosure
transition transition
C2 = Two-position 0040 = 40A A = 120V, 60 Hz K = Open
CB = Bypass 0080 = 80A B = 208V, 60 Hz S = NEMA 1
isolation C3 = Three-position
0100 = 100A E = 600V, 60 Hz J = NEMA 12
closed Switch 0150 = 150A G = 220V, 50 Hz R = NEMA 3R
transition 0200 = 200A H = 380V, 50 Hz
E = Drawout
CT = Closed 0225 = 225A K = 600V, 50 Hz
X = Fix mount
transition 0260 = 260A M = 230V, 50 Hz
DT = Delayed 0400 = 400A N = 401V, 50 Hz
transition Number of Poles 0600 = 600A O = 415V, 50 Hz
2 = Two-pole 0800 = 800A W = 240V, 60 Hz
Orientation 3 = Three-pole 1000 = 1000A X = 480V, 60 Hz
C = Contactor 4 = Four-pole 1200 = 1200A Z = 365V, 50 Hz

Logic
1 = ATC-100
3 = ATC-300
8 = ATC-800

Industrial Molded-Case Transfer Industrial Molded-Case Transfer Switch


Switch
AT V 3 KD A 3 0400 X S U

Certification
Type
U = UL listed
AT = Automatic Frame Size
R = UL recognized
MT = Manual (Ampheres)
X = No listing
NT = Non- Molded-case
Automatic device 1
MB = Maintenance FD = 30–150 Amperes Voltage Enclosure
Bypass KD = 225–300 0030 = 30A A = 120V, 60 Hz K = Open
LD = 400 0070 = 70A B = 208V, 60 Hz S = NEMA 1
MD = 600 0100 = 100A E = 600V, 60 Hz J = NEMA 12
Orientation
NB = 800–100 0150 = 150A G = 220V, 50/60 Hz R = NEMA 3R
C = Horizontal 0200 = 200A H = 380V, 50 Hz
V = Vertical 0225 = 225A K = 600V, 50 Hz
Switch
0300 = 260A M = 230V, 50 Hz
A = S1 (MCS) S2 (MCS)
Logic 0400 = 400A N = 401V, 50 Hz
B = S1 (MCB) S2 (MCB)
1 = ATC-100 0600 = 600A O = 415V, 50 Hz
C = S1 (MCB) S2 (MCS)
3 = ATC-300 0800 = 800A W = 240V, 60 Hz
D = S1 (MCS) S2 (MCB)
I = ATC-600 1000 = 1000A X = 480V, 60 Hz
X = No Logic 1200 = 1200A Z = 365V, 50 Hz
E = Electromechanical Number of Poles
1 Wall-Mount Breaker-Based Design
2 = Two-pole
3 = Three-pole
4 = Four-pole

19
Circuit Protection & Control Products Quick Selection Guide
Automatic Transfer Switch

Magnum-based Transfer Switches Magnum-based Transfer Switches

AT V I MG B 3 3200 X R U

Certification
Type
U = UL listed
AT = Automatic Frame Size (Ampheres)
R = UL recognized
CT = Closed MG = Magnum DS X = No listing
transition
BI = Bypass
transition Enclosure
CB = Closed Number of Poles S = NEMA 1
transition 2 = Two-pole R = NEMA 3R
bypass 3 = Three-pole T = Through-
isolation 4 = Four-pole the-door
NT = Non-auto design

Switch Amperes Voltage


Orientation A = Fixed mount, power case 0200 = 200A
V = Vertical A = 120V 60 Hz Three-phase Three-wire
switch (PCS) both 0300 = 300A B = 208/120V 60 Hz Three-phase Four-wire
B = Fixed mount, power case 0400 = 400A E = 600V 60 Hz Three-phase Three-wire
circuit breaker (PCB) both 0600 = 600A
Logic E = 600V 60 Hz Three-phase Four-wire
C = Fixed mount, PCB normal, 0800 = 800A
C = ATC-5000 G = 220/127V 50 Hz Three-phase Four-wire
PCS emergency 1000 = 1000A
I = ATC-600 G = 220/110V 50/60 Hz Single-phase Three-wire
D = Fixed mount, PCS normal, 1200 = 1200A
(open transition) H = 380/220V 50 Hz Three-phase Four-wire
PCB emergency 1600 = 1600A
I = ATC-800 K = 600V 50 Hz Three-phase Four-wire
E = Drawout, PCS both 2000 = 2000A
(closed transition) M = 230V 50 Hz Three-phase Three-wire
F = Drawout, PCB both 2500 = 2500A M = 230V 50 Hz Single-phase Three-wire
G = Drawout, PCB normal, 3200 = 3200A N = 401/230V 50 Hz Three-phase Four-wire
PCS emergency 4000 = 4000A O = 415/240V 50 Hz Three-phase Four-wire
H = Drawout, PCS normal, 5000 = 5000A W = 240/120V 60 Hz Single-phase Three-wire
PCB emergency
W = 240V 60 Hz Three-phase Three-wire
W = 240/120V 60 Hz Three-phase Four-wire,
hi-leg
W = 230/115V 60 Hz Single-phase Three-wire
X = 480V 60 Hz Three-phase Three-wire
X = 480/277V 60 Hz Three-phase Four-wire
X = 480/240V 50 Hz Single-phase Two-wire
X = 346/220V 50 Hz Three-phase Four-wire

20
Circuit Protection & Control Products Quick Selection Guide
Metering Devices

IQ130/140/150 Meter IQ130/140/150 Meter

IQ 150 M A 6 5 1 1
Model Series
130 = Volts/amps
140 = Power Frequency
150 = Energy 5 = 50 Hz system
6 = 60 Hz system Power Supply
Communications
1 = 90–265 Vac/dc
4 = 24–48 Vdc 0 = None
Meter Type 1 = Modbus RTU and KYZ pulse
M = Meter (with integral display) 2 = Modbus TCP and KYZ output (RJ45)
T = Transducer only (no display) Current Input
1 = 1A secondary
5 = 5A secondary

IQ 250/260 Meter IQ 250/260 Meter

IQ 250 M A 6 5 1 1 0

Model Series I/O Slot 2


250 = Energy 0 = None
260 = Power quality 1 = Two relay outputs/
two status inputs
Current Input 2 = Four KYZ pulses/
Meter Type 1 = 1A secondary four status inputs
M = Meter (with integral display) 5 = 5A secondary 3 = Four analog outputs: 0–1 mA
T = Transducer only (no display) 4 = Four analog outputs: 4–20 mA

Data Logging
I/O Slot 1
A = None
0 = None
L = Data logging
1 = Two relay outputs/
two status inputs
2 = Four KYZ pulses/
Frequency Power Supply four status inputs
5 = 50 Hz system 1 = 90–265 Vac/Vdc 3 = Four analog outputs: 0–1 mA
6 = 60 Hz system 4 = 24–60 Vdc 4 = Four analog outputs: 4–20 mA

21
Circuit Protection & Control Products Quick Selection Guide
Metering Devices

Power Xpert Meter 2000 Power Xpert Meter 2000

PXM 2250 M A 6 5 1 0 5
Model Series
2250 = Energy meter I/O Slot 2
2260 = Power quality meter 5 = Gateway card
2270 = Power quality plus meter
2280 = Power quality plus with up to 64 Power Supply
samples/cycle waveform recording I/O Slot 1
1 = 90–265 Vac/Vdc
meter 4 = 24–60 Vdc 0 = None
2290 = Power quality plus with up to 512 1 = 2 Relay outputs/2 status inputs
samples/cycle recording meter 2 = 4 KYZ pulses/4 status inputs
Current Input 3 = 4 Analog outputs: 0–1 mA
1 = 1A secondary 4 = 4 Analog outputs: 4–20 mA
Meter Type
5 = 5A secondary
M = Meter (with integral display)
T = Transducer only (no display)

Frequency
5 = 50 Hz system
6 = 60 Hz system

Power Xpert Meter 4000/6000/8000 Power Xpert Meter 4000/6000/8000

PXM 8 0 5 1 A 1 B B

Card Slot 3 Configuration


Model Series
A = No card option
4 = 4000 (Standard
B = I/O option card (8 digital inputs,
power quality, 2 GB)
2 solid-state outputs, 3 relay outputs)
6 = 6000 (Enhanced
power quality, 4 GB)
8 = 8000 (Premium PQ
w/ transient capture, 8 GB) Card Slot 2 Configuration
A = No card option
B = Communication expansion card
Voltage Input Configuration for LAN/WAN Ethernet
0 = Standard (V1, V2, V3, V4) networking w/10/100Base-T,
2 = Standard plus auxiliary (V6, V7, V8) 100F, RS-485, RS-232 ports

Card Slot 1 Configuration


Power Supply Configuration
1 = Standard Communications Module with RS-485
1 = Standard 100–240 Vac or
110–250 Vdc power supply
4 = 24–48 Vdc option (future option)

Example 1: PXM8251A5BB (PXM 8000 meter, w/ VAUX, std. pwr., com. exp. and I/O cards)
Example 2: PXM6251A6BA (PXM 6000 meter, w/ VAUX, std. pwr., com. exp.card)

22
Circuit Protection & Control Products Quick Selection Guide
xStart Series Motor Control & Protection

DILM Contactor (up to 170A) DILM Contactor (up to 170A)

DILM 7 - 10 (24 VDC)

Designation Operational Voltage


DILM = Contactor AC 50Hz
24, 110, 220-230, 380-400V
AC 50/60Hz
Ampere Rating 24, 110, 220V
7A-170A DC
24, 110, 220
Auxiliary Contact RDC24 = 24-27
RDC130 = 10-130
10 = 1NO
RDC240 = 200-240V
01 = 1NC
21 = 2NO + 1NC
22 = 2NO + 2NC
32 = 3NO + 2NC

DILM Large Contactor (185~300A) DILM Large Contactor (185~300A)

DILM 185A / 22 (RAC24)

Operational Voltage
AC 50/60Hz
RAC24 = 24 V
RAC48 = 48 V
Designation RAC120 = 120 V
DILM = Contactor RAC240 = 240 V
RAC440 = 440 V
RAC500 = 500 V
Ampere Rating DC
RDC24 = 24-27 V
DILM...A Series = 185, 225, 300A
RDC60 = 48-60 V
Auxiliary Contact RDC130 = 110-130 V
1st = 1NO RDC240 = 200-240 V
2st = 1NC
22 = 2NO + 1NC

23
Circuit Protection & Control Products Quick Selection Guide
xStart Series Motor Control & Protection

DILM/DILH Large Contactor DILM/DILH Large Contactor

DILM 400 - S / 22 (110-120 V 50/60 Hz)

Designation Operational Voltage


DILM, DILH = Large contactor AC 50/60Hz
110-120 V, 220-240 V
AC 40-60Hz
Ampere Rating RAC500 = 250-500 V
DILM Series = 400 to 820A DC
DILH Series = (AC-1)1400 to 2600A RDC48 = 24-48 V
AC/DC
RA110 = 48-110 V 40-60 Hz/
Product Family 48-110 DC
Blank = Advanced type RA250 = 110-250 V 40-60 Hz/
S = Standard type 110-250 DC
Auxiliary Contact
RAW250 = 230-250 AC/DC
1st = 1NO
2st = 1NC
22 = 2NO + 1NC

ZB Overload Relay ZB Overload Relay

ZB 12 - 10

Designation
ZB = Overload relay
Ampere Rating
0.1A-175A
Frame Size
12: Frame I = 0.1-16A
32: Frame II = 0.1-38A
65: Frame III = 6-75A
150: Frame IV = 25-175A

24
Circuit Protection & Control Products Quick Selection Guide
xStart Series Motor Control & Protection

ZEB Overload Relay ZEB Overload Relay

ZEB 12 1.65 - GF / KK

Designation Mounting Mode


ZEB = Electronic overload relay KK = Direct to contactor
Blank = Separate mount

Frame Size Product Family


12: Frame I = 0.33-20A GF = Ground fault function
32: Frame II = 0.33-45A Blank = None
65: Frame III = 9-100A
150: Frame IV = 20-170A
Ampere Rating
1.65 = 0.33-1.65A
5 = 1-5A
20 = 4-20A
45 = 9-45A
100 = 20-100A

PKZ Motor Protective PKZ Motor Protective Circuit Breaker


Circuit Breaker
PKZM - 10

Designation
PKZM0, PKZMC = 0.16 to 32A
PKZM4 = 16 to 65A Ampere Rating
PKE = 0.3-65A
0.16A-32A

25
Circuit Protection & Control Products Quick Selection Guide
E Line Series Motor Control & Protection

XTCG Contactor XTCG Contactor

XTCG 025 C 00 AO

Designation Operational Voltage


XTCG = E line contactor B2 = 24V AC50/60Hz
DV = 36V AC50/60Hz
C2 = 48V AC50/60Hz
Ampere Rating E2 = 110V AC50/60Hz
7A-95A AO = 220V AC50/60Hz
AR = 380V AC50/60Hz
B0 = 24V DC
Frame Size
B = 7-12A
C = 18-38A
D = 40-65A
E = 80-95A Auxiliary Contact
00

XTRG Contactor Relay XTRG Contactor Relay

XTRG 10 B21 AO

Designation Operational Voltage


XTRG = E line Contactor Relay B2 = 24V AC50/60Hz
DV = 36V AC50/60Hz
C2 = 48V AC50/60Hz
Ampere Rating E2 = 110V AC50/60Hz
Ith: 10A AO = 220V AC50/60Hz
AR = 380V AC50/60Hz
B0 = 24V DC

Auxiliary Contact
30 = 3NO
21 = 2NO/1NC
12 = 1NO/2NC
03 = 3NC

XTOG Overload Relay XTOG Overload Relay

XTOG 097 EC1

Designation
XTOG = Thermal Overload Relay
Frame Size
BC1 = 0.1-12A
Ampere Rating CC1 = 12-32A
0.3A-97A DC1 = 17-65A
EC1 = 37-97A

26
Circuit Protection & Control Products Quick Selection Guide
Soft Start Controllers

S801+ Open Soft Starters S801+ Open Soft Starters

S 801+ N66 N 3 S

S = Soft starter
S = Standard soft starter

801+ = Non-combination
soft starter Number of Poles
3 = Three-pole device

Ampere Rating
N37 = 37A U50 = 500A Options
N66 = 66A V36 = 360A N = Standard
R10 = 105A V42 = 420A
R13 = 135A V50 = 500A
T18 = 180A V65 = 650A
T24 = 240A V72 = 720A
T30 = 304A V85 = 850A
U36 = 360A V10 = 1000A
U42 = 420A

S811+ Open Soft Starters S811+ Open Soft Starters

S 811+ T 30 N 3 S

S = Soft starter
S = Standard soft starter

811+ = Non-combination
soft starter Number of Poles
3 = Three-pole device

Frame Size Ampere Rating


N = 65 mm 37 = 37A 36 = 360A Options
R = 110 mm 66 = 66A 42 = 420A N = No options
T = 200 mm 10 = 105A 50 = 500A P = Premium, 600V rated
U = 200 mm 13 = 135A 65 = 650A V = Premium, 690V rated
V = 290 mm 18 = 180A 72 = 720A (S811+T18V35 through
24 = 240A 85 = 850A S811+V85V35)
30 = 304A 10 = 1000A

27
Circuit Protection & Control Products Quick Selection Guide
Soft Start Controllers

DS7 Soft Start Controllers DS7 Soft Start Controllers

DS7 - 3 4 0 SX 004 N 0 - N
Device Series Options
DS7 = Generation 7 N = No option
D = SmartWire-DT

Number of Phases
3 = Three-phase mains Protection Type
supply voltage 0 = IP20

Voltage Class Radio Interference


4 = 400V Suppression Filters
(380V –15% to 480V +10%) 4 = No internal radio interference
suppression filters

Control Voltage Supply Device Version


0 = 24 Vac/Vdc SX = Standard soft starters Rated Operational Current
2 = 110/230 Vac with internal bypass 004 = 4A
D = 24 Vdc SmartWire-DT •

200 = 200A

28
Circuit Protection & Control Products Quick Selection Guide
Adjustable Frequency Drives

DG1 General Purpose Drive DG1 General Purpose Drive


Series Power Part Options

D G 1 – 3 4 4D8 F B – C 21 C

Basic Naming Display Option


D = Drive N = No display
C = LCD (graphical)
Series
G = General purpose Enclosure (IP Rating)
21 = IP21
54 = IP54
Product Generation
1 = First generation
2 = Second generation Coating of Boards
N = None
C = Coated
Phase Reference
3 = 3~ INPUT/3~ OUTPUT
Internal Brake Chopper
N = No brake chopper
Input/Output Voltage Rating B = Brake chopper
2 = 220V (200–240V ±10%)
4 = 400V (380–500V ±10%)
5 = 690V (525–690V ±10%) Internal EMC Filter
N = No lter
F = Internal EMC lter

Output Current Rating (CT)


208–240V 380–500V 525–690V
3D7 = 3.7A, 0.55 kW, 0.75 hp 2D2 = 2.2A, 0.75 kW, 1 hp 3D3 = 3.3A, 1.5 kW, 2 hp
4D8 = 4.8A, 0.75 kW, 1 hp 3D3 = 3.3A, 1.1 kW, 1.5 hp 4D5 = 4.5A, 2.2 kW, 3 hp
6D6 = 6.6A, 1.1 kW, 1.5 hp 4D3 = 4.3A, 1.5 kW, 2 hp 7D5 = 7.5A, 3.7 kW, 5 hp
7D8 = 7.8A, 1.5 kW, 2 hp 5D6 = 5.6A, 2.2 kW, 3 hp 010 = 10A, 5.5 kW, 7.5 hp
011 = 11A, 2.2 kW, 3 hp 7D6 = 7.6A, 3 kW, 5 hp 013 = 13.5A, 7.5 kW, 10 hp
012 = 12.5A, 3 kW, 5 hp (VT) 9D0 = 9A, 4 kW, 7.5 hp (VT) 018 = 18A, 11 kW, 15 hp
017 = 17.5A, 3.7 kW, 5 hp 012 = 12A, 5.5 kW, 7.5 hp 022 = 22A, 15 kW, 20 hp
025 = 25A, 5.5 kW, 7.5 hp 016 = 16A, 7.5 kW, 10 hp 027 = 27A, 18 kW, 25 hp
031 = 31A, 7.5 kW, 10 hp 023 = 23A, 11 kW, 15 hp 034 = 34A, 22 kW, 30 hp
048 = 48A, 11 kW, 15 hp 031 = 31A, 15 kW, 20 hp 041 = 41A, 30 kW, 40 hp
061 = 61A, 15 kW, 20 hp 038 = 38A, 18 kW, 25 hp 052 = 52A, 37 kW, 50 hp
075 = 75A, 18.5 kW, 25 hp 046 = 46A, 22 kW, 30 hp 062 = 62A, 45 kW, 60 hp
088 = 88A, 22 kW, 30 hp 061 = 61A, 30 kW, 40 hp 080 = 80A, 55 kW, 75 hp
114 = 114A, 30 kW, 40 hp 072 = 72A, 37 kW, 50 hp 100 = 100A, 75 kW, 100 hp
143 = 143A, 37 kW, 50 hp 087 = 87A, 45 kW, 60 hp 125 = 125A, 90 kW, 125 hp
170 = 170A, 45 kW, 60 hp 105 = 105A, 55 kW, 75 hp 144 = 144A, 110 kW, 150 hp
211 = 211A, 55 kW, 75 hp 140 = 140A, 75 kW, 100 hp 208 = 208A, 160 kW, 200 hp
261 = 261A, 75 kW, 100 hp 170 = 170A, 90 kW, 125 hp
205 = 205A, 110 kW, 150 hp
261 = 261A, 150 kW, 200 hp

29
Circuit Protection & Control Products Quick Selection Guide
Adjustable Frequency Drives

DE1 Variable Speed Starter DE1 Variable Speed Starter


Series Power Part Options

D E 1 – 1 2 4D8 F N – N 20 N

Basic Naming Coating of Boards


D = Drive N = None
C = Coated
Series
E = Economy Enclosure (IP Rating)
20 = IP20 / NEMA 0
Product Generation
1 = First generation Display Option
2 = Second generation N = No Display

Phase Reference Internal Brake Chopper


1 = 1~ INPUT / 3~ OUTPUT N = No brake chopper
3 = 3~ INPUT / 3~ OUTPUT
Internal EMC Filter
Input/Output Voltage Rating N = No filter
2 = 230 V (200 - 240 V ±10 %) F = internal EMC filter
4 = 400 V (380 - 480 V ±10 %)
Output Current Rating
4D8 = 4.8 A
012 = 12 A

M-Max Series Adjustable M-Max Series Adjustable Frequency AC Drives


Frequency AC Drives
M-Max 1 1 AA 1D7 F 0 - 0

Designation Option
M-Max = Base catalog number 0 = Full version

Phase
Enclosure Class
1 = Single-phase
0 = NEMA 0 or IP20
3 = Three-phase
1 = NEMA 1 or IP21

Voltage
1 = 120 V EMC Filter
3 = 230 V F = Filter
4 = 380 V N = No filter
Output Current
1.7-14A
Software Designation Series 1D7 = 1.7A…
AA 014 = 14A

30
Circuit Protection & Control Products Quick Selection Guide
Adjustable Frequency Drives

SVX9000 Adjustable Frequency SVX9000 Adjustable Frequency Drives


Drives
SVX 010 A 1 4 A 1 B 1

Board Modifications
Product Family
1 = Standard boards
SVX = Open drives 2 = Conformal (varnished) coating

Horsepower Rating (HP)


Brake Chopper Options
F07 = 3/4 040 = 40
001 = 1 050 = 50 Voltage Rating N = No brake chopper circuit
F15 = 1-1/2 060 = 60 B = Internal brake chopper circuit
2 = 230 (208-240) V
002 = 2 075 = 75 4 = 380 (380-500) V
003 = 3 100 = 100 5 = 690 (525-690) V Input Options
004 = 5(IL) 125 = 125 1 = Three-phase, EMC H
005 = 5 250 = 250 Enclosure 2 = Three-phase, EMC N
006 = 7-1/2(IL) 300 = 300 4 = Three-phase, EMC L
0 = IP00
007 = 7-1/2 350 = 350
1 = IP21
010 = 10 400 = 400
2 = IP54 Keypad
015 = 15 500 = 500
020 = 20 550 = 550 A = Alphanumeric
025 = 25 600 = 600 G = Liquid crystal panel
030 = 30 700 = 700

AFD Software Series


A = Standard software

SLX Adjustable Frequency Drives SLX Adjustable Frequency Drives

SLX 010 A 1 4 A 1 B 1

Board Modifications
Product Family
1 = Standard boards
SLX = Open drives 2 = Conformal (varnished) coating

Horsepower Rating (HP)


001 = 1 007 = 7-1/2 Brake Chopper Options
F15 = 1-1/2 010 = 10 B = Internal brake chopper circuit
002 = 2 015 = 15
003 = 3 020 = 20
005 = 5 025 = 25 Input Options
006 = 6 030 = 30 1 = Three-phase, EMC H

AFD Software Series Keypad


A = Standard software A = Alphanumeric

Enclosure Voltage Rating


1 = IP21 4 = 380 (380-500) V
2 = IP54

31
Circuit Protection & Control Products Quick Selection Guide
Adjustable Frequency Drives

SPX9000 Adjustable Frequency SPX9000 Adjustable Frequency Drives


Drives
SPX 010 A 1 4 A 1 B 1

Board Modifications
Product Family
1 = Standard boards
SPX = Open drives 2 = Conformal (varnished) coating

Horsepower Rating (HP)


Brake Chopper Options
F07 = 3/4 100 = 100
001 = 1 125 = 125 Voltage Rating N = No brake chopper circuit
F15 = 1-1/2 250 = 250 B = Internal brake chopper circuit
2 = 230 (208-240) V
002 = 2 300 = 300 4 = 380 (380-500) V
003 = 3 350 = 350 5 = 690 (525-690) V Input Options
004 = 5(IL) 400 = 400 1 = Three-phase, EMC H
005 = 5 500 = 500 2 = Three-phase, EMC N
Enclosure
006 = 7-1/2(IL) 550 = 550 4 = Three-phase, EMC L
007 = 7-1/2 600 = 600 0 = IP00
010 = 10 700 = 700 1 = IP21
015 = 15 800 = 800 2 = IP54 Keypad
020 = 20 900 = 900 A = Alphanumeric
025 = 25 H10 = 1000 G = Liquid crystal panel
AFD Software Series
030 = 30 H12 = 1200
A = Standard software
040 = 40 H13 = 1300
050 = 50 H15 = 1500
060 = 60 H16 = 1600
075 = 75 H20 = 2000

32
Circuit Protection & Control Products Quick Selection Guide
Pushbuttons and Indicating Lights

A22 Pushbuttons and Indicating A22 Pushbuttons and Indicating Lights


Lights
A22(M) (1) - (2) / (3) / (4)

Lamp Socket Block


F = Bulb elements without resistor
A22 Series Pushbuttons FR = Bulb elements with resistor
22-mm pushbuttons
A22 = Front bright ring
A22M = Front dark ring Contact Blocks
K10 = 1NO
K01 = 1NC
Operator Type K11 = 1NO + 1NC
Flush Actuator KC/I = Control station
RD = Flush actuator KC11 A/I = 1NO + 1NC/2 NC Control station
Illuminated Pushbuttons
R LT = Illuminated, flush, momentary
RLTH = Illuminated extended momentary Button Plate Color
RLTR = Illuminated extended maintained Non-Illuminated Pushbuttons, Flush, Maintained
Illuminated Double Operator 01 = Black
QDDL = Illuminated double operator 02 = White
03 = Green
Mushroom Head Pushbuttons
04 = Red
RP = Mushroom head pushbuttons
05 = Yellow
RPSR = Key-release mushroom head operator
06 = Blue
Non-Illuminated Emergency Stops 10,11,12,13,14,19,20,32,37,38 = Actuator with symbol
RPV = Non-illuminated push-pull emergency stop X = No plate
E.STOP HEADER = Emergency stop operator (turn to reset)
Illuminated Pushbuttons
Indicating Lights WS = White
RL = Extended indicator light GN = Green
RLF = Flush indicating light RT = Red
LC = Compact indicating light GE = Yellow
Selector Switch WS11 = White with symbol
RWK1R = 2-position, maintained, 60° Double Actuator Pushbuttons With Indicator Light
RWK1 = 2-position, momentary, 45° 11/10 = Green / Red
RWK1V = 2-position, maintained, 90°
Mushroom Head Pushbuttons
RWK3R = 3-position, maintained, 60°
GN11 = Green with symbol
RWK3 = 3-position, momentary, 45°
RT10 = Red with symbol
Key-Operated Selector Switches
Indicating Lights
RS = 2-position, maintained, 60°
WS = White
RS3 = 3-position, maintained
GN = Green
RS3-KMS1-A4 = 3-position, momentary
RT = Red
RS3-KMS1-A2 = 2-position, momentary
DE = Yellow
Palm Switches BL = Blue
FAK-S = 1NO + 1NC
Compact Indicator
FAK-R = 2NC
W = White
G = Green
R = Red
Y = Yellow

Note: Contact block Catalog Number Selection


A22-EK10(C) = 1 Normal open contact
A22-EK10(C) = 1 Normal closed contact
A22-EC11 = 1 Normal open contact, 1 Normal closed contact
A22-EC20 = 2 Normal open contact
A22-EC02 = 2 Normal closed contact

33
Circuit Protection & Control Products Quick Selection Guide
Pushbuttons and Indicating Lights

M22 Pushbuttons and Indicating M22 Pushbuttons and Indicating Lights


Lights
M 22 (S) - □ - □ / □

Contact Blocks
Designation K10 = 1NO
M = M series pushbuttons K01 = 1NC
K11 = 1NO + 1NC
Frame Size K20 = 2NO
22 = 22-mm pushbuttons KC11/IY = Emergency-stop button (1NO + 1NC)
KC02/IY = Emergency-stop button (2NC)
Product Family
Blank = Silver Button Plate Color
S = Black Flush, Extended, Mushroom Head Pushbuttons
S = Black
S-XO = (Black)
Operator Type
W = White
Non-Illuminated Pushbuttons, Flush, Maintained W-XI = (White)
D = Flush momentary R = Red
DR = Flush maintained R-XO = (Red)
Non-Illuminated Pushbuttons, Extended, Maintained G = Green
DH = Extended momentary G-XI = (Green)
DRH = Extended maintained Y = Yellow
Mushroom Head Pushbuttons B = Blue
DP = Non-illuminated momentary mushroom head pushbutton Illuminated Selector Switches,
DRP = Non-illuminated maintained mushroom head pushbutton Illuminated Pushbuttons,
Non-Illuminated Emergency Stops Illuminated Selector Switches
PV = Non-illuminated push-pull emergency stop W = White
PVL = Illuminated push-pull emergency stop R = Red
PVT = Non-illuminated twist-to-release emergency stop G = Green
PVLT = Illuminated twist-to-release emergency stop Y = Yellow
PVS = Non-illuminated keyed release (red operator only) B = Blue
Double Pushbuttons
DDL = Extended buttons and light
Illuminated Pushbuttons
DL = Illuminated, flush, momentary
DRL = Illuminated, flush, maintained
DLH = Illuminated extended momentary
DRLH = Illuminated extended maintained
Illuminated Selector Switches
WLK = Illuminated knob type momentary, two-position
WRLK = Two-position, maintained
WLK3 = Illuminated knob type momentary, three-position
WRLK3 = Three-position, maintained
Indicating Lights
L = Flush indicating light
LH = Extended indicator light
Non-Illuminated Selector Switches
W = Momentary rotary
WR = Maintained rotary
WK = Momentary knob
WRK = Maintained knob
WKV = Maintained V-position knob
W3 = 3-position, momentary
WR3 = 3-position, maintained
WK3 = 3-position, momentary
WRK3 = 3-position, maintained
WR4 = 4-position, maintained
WRK4 = 4-position, maintained
D4 = Four-way pushbutton, momentary, non-interlocked
WJ = Joystick, momentary
WRJ = Joystick, maintained
Key-Operated Selector Switches
WS = Two-position, momentary
WRS = Two-position, maintained
WS3 = Three-position, momentary
WRS3 = Three-position, maintained

34
Circuit Protection & Control Products Quick Selection Guide
Cam Switches / Switch-disconnectors

T Cam Switches T Cam Switches

T0 - 1 - 8200 / E + □

Frame Size
T = 20A Accessories
T3 = 32A
T5 (B) = 63A
T5 = 100A Mounting Form
Main Switches
EA/SVB = Flush mounting
Number of Contact Chambers I1 (I2,I4,I5)/SVB = Surface mounting
1 = Contact units V/SVB = Rear mounting
Other
E = Flush mounting
Contact Sequence Number EZ = Center mounting
I1 (I2,I4,I5) = Surface mounting
IVS = Distribution board - mounting
Z = Rear mounting

P Switch-disconnectors P Switch-disconnectors

P1 - 25 / Z / N

Frame Size
P1 = 25A, 32A Accessories
P3 = 63A, 100A

Mounting Form
Main Switches
Rated Uninterrupted Current
IVS = Distribution board - mounting
25, 32, 63, 100A E = Flush mounting
EA/SVB = Flush mounting main switch
I…SI = Safety switches
EZ = Center mounting
Z = Rear mounting
V/SVB = Rear mounting main switches
I1 (I2,I4,I5) = Surface mounting
I1 (I2,I4,I5)/SVB = Surface mounting main switches

35
Circuit Protection & Control Products Quick Selection Guide
Position Switches

LSE-Titan Plastic Electronic Safety LSE-Titan Plastic Electronic Safety Position Switches
Position Switches
LSE - 11

Designation Contacts
LSE = Plastic electronic safety 02 = 2NC
position switches 11 = 1NO + 1NC
AI = Analog 4–20 mA
AU = Analog 0-10 V

LS-Titan Metal Safety Switches LS-Titan Metal Safety Switches

LS - 11 S / RL

Designation Operating Heads


LS = Plastic housing RL = Roller lever
LSM = Metal housing S = Spring rod actuator
P = Roller plungers
RLA = Adjustable roller levers
RR = Actuating rod
Contacts L (LS, LB) = Roller lever (Long, Short, Large)
02 = Cage clamp, 2NC
S02 = Screw terminal, 2NC
11 = Cage clamp, 1NO + 1NC
S11 = Screw terminal, 1NO + 1NC Contact Type
20 = Cage clamp, 2NO Blank = Standard contact
S20 = Screw terminal, 2NO D = Delay contact, early close, delay open
S = Snap-action contact
A = Same contact travel

36
Circuit Protection & Control Products Quick Selection Guide
Position Switches

LSR-TKG/TS Hasp/Hinge LSR-TKG/TS Hasp/Hinge Operated Safety Switch


Operated Safety Switch
LSR - S02 - 1 - IA / TKG

Designation
Limit - Switch - Robust TKG = Hasp operated safety switch
TS = Hinge operated safety switch

Auxiliary Contact
S02 = Screw terminal, 2NC I = Iso-Enclosure, small (DIN 50 047)
S11 = Screw terminal, 1NO + 1NC IA = Iso-Enclosure, wide

1 = 5° Switching angle, right and left

LS…ZBZ Solenoid Safety LS…ZBZ Solenoid Safety Interlock Switches


Interlock Switches
LS - S11 - 24D FT - ZBZ/X

Designation
Limit - Switch Safety switch, with actuator

Auxiliary Contact
S02 = Screw terminal FT = Spring-powered interlock
S11 = Screw terminal MT = Magnet-powered interlock

Rated Control Voltage for Magnet Drive


24D = 24Vdc
120A = 120V50/60Hz
230A = 230V50/60Hz

37
Circuit Protection & Control Products Quick Selection Guide
Position Switches

LS-ZB Safety Position Switches LS-ZB Safety Position Switches

LS - 02 - ZB

Designation
Limit – Switch

Contacts
02 = Cage clamp, 2NC ZB = With actuator
S02 = Screw terminal, 2NC
11 = Cage clamp, 1NO + 1NC
S11 = Screw terminal, 1NO + 1NC
11S = Cage clamp, 1NO + 1NC, snap-action contact
S11S = Screw terminal, 1NO + 1NC, snap-action contact

LS4-ZB Safety Position Switches LS4-ZB Safety Position Switches

LS4 / S11-1 / IA / ZB

Designation
Limit – Switch – 4 = Size 4

ZB = With actuator
Auxiliary Contact
S11-1 = Screw terminal, 1NO + 1NC
S11-7 = Screw terminal, 2NO + 1NC

I = Enclosure, small and short


IA = Enclosure, large and long
IB = With actuator

38
Circuit Protection & Control Products Quick Selection Guide
PLC

XC PLC XC PLC

XC - CPU101 - C128K - 8DI-6DO

Designation
C = CPU module
Function
IOC = I/O module
V = Text display 8 Digital inputs,
T = Accessories 6 Digital outputs

Model Number Memory Capacity


101 = 100 series 64K, 128K, 256K, 512K, 4M
201 = 200 series
121 = All-in-one 100 series

XION Remote I/O Module XION Remote I/O Module

XN-GWBR - PBDP

Module Type
PBDP = Profibus DP Field bus
Designation CANOPEN = Canopen Field bus
DNET = Device net Field bus
GW = Gateway
MODBUS-TCP = Modbus TCP Gateway
BR = Power
24VDC = 24V DC
PF = Power
R = Relay Output
*DI = I/O Module
I = Current
P/S = Base
U = Voltage
KO/QV = Accessories
SB = Wiring Base

39
Eaton is a power management company with 2013 sales of
$22.0 billion. Eaton provides energy-efficient solutions that help
our customers effectively manage electrical, hydraulic and
mechanical power more efficiently, safely and sustainably. Eaton
has approximately 100,000 employees and sells products to
customers in more than 175 countries. For more information,
visit www.eaton.com/seasia-electrical.

Electrical Sector Asia Pacific


No.3, Lane 280, Linhong Road,
Changning District, Shanghai

Eaton Industries Pte Ltd


Electrical Sector
4 Loyang Lane #04-01/02
Singapore 508914
www.eaton.com/seasia-electrical
Eaton is a registered trademark
© 2014 Eaton Corporation of Eaton Corporation.
All Rights Reserved
Printed in Singapore All trademarks are property of their
December 2014 respective owners.

You might also like