You are on page 1of 2

MASTER MAKING SECTION

REMOVAL

1. REMOVAL
1. THERMAL PRINT HEAD
REMOVAL
1) Turn ON the power and open the Scanner table. Then turn OFF the power. (The thermal print head is raised
automatically.)
2) Remove mounting screws (× 2) of the master making unit cover, remove the cover.
3) Remove the fixing screws of thermal print head ground wire, raise the ground wire.
Master making unit cover

Bind M3 × 6 (× 2)

Ground wire
Bind M3 × 6

4) Open the master making unit, place the sheet under the thermal print head so that the screw will not fall into
Machine.
5) Loosen the fixing screws (× 2) of the copy guide plate (lower) assy, disconnect the connector from the master
end sensor light receiving section to remove the assembly.

Loosen screw

Fig. a

Copy guide plate (lower) assy.

4-1 GR3770
MASTER MAKING SECTION
REMOVAL

6) Remove mounting screws (× 2) of the thermal print head, disconnect connectors (x 2) and remove the unit.

Fig. b

Pan-head IT M3 × 7 (× 2)

Thermal print head

- Precautions in Removal -
• Be careful not to damage the heating elements of the thermal print head.
• Be careful not to touch the metal pins of the connectors.
Static electricity from your body may damage the thermal print head.
- Precations in Assembly -
• For fixing the thermal print head, first adjusting half-pierce, apply the screw to the frame of the master-making
unit to fasten it. (Fig. b)
• Be sure to adjust the thermal power each time the thermal print head is replaced, referring to the page 4-4.

GR3770 4-2