You are on page 1of 27

projector

sensor ASS'Y(LT camera)


sensor ASS'Y(LT camera) sensor ASS'Y(RT camera)

sensor ASS'Y(RT camera)

screen

GS Statiom

Criteria of 'T'
Criteria of 'T'
keypad rremote control

swingplate

ABBREVIATION
GS : GOLFZON SIMULATOR
VBS : VISION SENSOR + BOTH HANDS + SWING PLATE

2. GS ROOM(VBS)
GS(VBS) SYSTEM BASIC COMPOSITION 2-16
slope

GS Station

GS Station access hole

ball collector access hole


1.ball collector

controller access hole


ball collector access hole 1. Vision FA Controller
1. ball collector 2. auto tee up controller

Criteria of 'T'
controller access hole
1. Vision FA Controller
2. auto tee up controller

Criteria of 'T'

swingplate

2. GS ROOM(VBS)
GS(VBS) FLOOR basic drawing 2-17
9,400
500 3,500 1,900 3,500
3,400 200 1,350 350
100 Secure minimum 800mm for safety
from plate to fabric finishing

1,070 1,200(minimum safety distance


PC Consol pipe line(make a hole side of hitting area)
55

765 765

785
7. GS Station access hole

1,165
1,185
600
4. ball collector access hole 6. GS Station
products from supplier

100
1,130

375
535
5. controller access hole
Criteria of 'T'
2. front accecc hole
4,860(center to center of pipe)

3.rear access hole


4,700(screen ratio 16:10)

The best case is that center of screen


4,860(screen size)

and "T" are located in a straight line, 1. swing plate


SCREEN

2,350
the second best case is that center of
4,810
4,700

4,700
C.L

screen and "T"'s gap must be products from supplier

2,000
4000mm below.
VAR.+12 VAR. APP. TILE FIN.

535 Criteria of 'T'


APP. WOOD SHEET FIN. 5. controller access hole

375

100
APP. ROLL CARPET FIN.

4. ball collector access hole

600

1,185
ENT.

1,185
785

765 765

APP. ROLL CARPET FIN.


55

THK.55mm APP. FABRIC PANEL FIN.


Secure minimum 800mm for safety
from plate to fabric finishing

500 3,500 1,900 3,500


9,400

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
2. GS ROOM(VBS)
GS(VBS) FLOOR PLAN GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-18
Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
9,400
500 3,500 1,900 3,500
3,400 200 1,350 350
100
55

300 100
300 920

1,165
THK. 12mm PLYWOOD 2PLY

600
access hole install to support hehid of access hole cover
600 492 120 180 500 190

100
200 340 120 180 500 560

535
300
600

2,350
4,810
4,700

4,700
swingplate frame work

2,350
660
(2,350x 1,350)

1,350 350

300
CLEAR OPEN
400

30 6 100 6 30
12 12

535
200 340 120 180 500 560

100
492 120 180 500 190

600
access hole
ENT.

1,185
Secure 100mm for clear open
considering side of carpet
finishing
55

500 3,500 1,900 3,500


9,400

V ROOM & VBOOTH INTERIOR GUIDELINE Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any

GS(VBS) FLOOR FRAME PLAN GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-19
2. GS ROOM(VBS) Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
9,400
500 3,500 1,900 3,500
3,400 200 1,350 350
100
55

FL +185 GS Station pipe line ( side of hitting area)


(including finishing)

1,165,555
GS Station pipe line(W:150 X H:70)
ball collector pipe path(W:120 X H:152)
SLOPE : 1/2
FL +170 Controller line path( W:500 X H:70)
Gate for ball blocking (make a hole of ball enteranceW:300 X H:100)
Prevent to slip down the access hole door
Prevent to slip down ball collector (W:32 X D:32 X H:170)
120 500 210 350
180

access hole access hole


FL +185 FL +185
(including finishing) (including finishing)
SCREEN

2,350
4,810
4,700

4,700
2,350

2,350
C.L

FL +152
(including finishing)

VAR.+12 VAR.

120 500 210 350


180

200 350
Prevent to slip down the access hole door
Prevent to slip down ball collector FL +170 W:30 X D:30 X H:170)
ENT.

1,185
Gate for ball blocking (make a hole of ball enteranceW:300 X H:100) Controller line path(W:500 X H:70)
SLOPE : 1/2 ball collector pipe path(W:120 X H:152)
FL +185
(including finishing)
55

500 3,500 1,900 3,500


9,400

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
2. GS ROOM(VBS)
GS(VBS) FLOOR LEVEL PLAN GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-20
Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
3,500

secure minimum 200mm space from We recommend that access hole is


wall (if not, camera cap could not be installed 300mm from projector, not
installed) exceed 1,000mm extra space for projector installation

projector(products from supplier)

500 S

260
RR

1,350
S

1,300
RT

300
Criteria of 1,000
'T'

APP. FABRIC PANEL FIN.(TYPE B)


SCREEN

CONTROL

2,000
C.L

BOX

APP. PAINT FIN.


1,000
APP. FABRIC PANEL FIN.(TYPE A)
Criteria of 'T'

300
LT

1,300
1,500 1,000

1,350
R

LL
260

200
S

secure minimum 200mm space from


wall (if not, camera cap could not be
installed)

LEGEND

SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE

cassette type air RR camera cover : SPOT LIGHT


projector CP-F500 S SPEAKER 2EA
conditioner
S air supply 1EA LL sensor camera (LED 10W)
3EA
(recommend 2
1EA
RT sensor camera : DOWN LIGHT
access hole 450X450 sprinkler Applied for actual size R exhaust 1EA
WAY) LT sensor camera (LED 20W)
8EA

2. GS ROOM(VBS)
GS(VBS) CEILING PLAN 2-21
4,810 4,700
55 4,700 55 2,000
770 770 960 200

-
-
APP. BLIND FIN.

100
55

900
1,800

250
SCREEN
180

1,200
3,020
3,100

CCTV
(adjust to 16:10 ratio based on actual circumstance) F.

3,240
3,300

3,300

3,300
shooting
products from supplier evacuation
guide map

2,400
1,200
F.

1,200
fire extinguisher
SIGN

550
280
200

60
- -
S.ST'L(H/L) FIN. MT CA
SLOPE:APP. CARPET FIN. APP. WOOD SHEET FIN. -
-
-
-
APP. FINISHING MATERIALS FIN.
1 ELEVATION - 1 2 ELEVATION - 2
- SCALE : 1/60 - SCALE : 1/60

9,400
3,500 1,900 3,500 500

55
1,000
950 1,600

700 700 700 700 700

1,000

3,020
3,240
3,300

3,300
800

poster poster poster poster


(450X620) (450X620) (450X620) (450X620)

1,000
1,100

VAR.

280
60

3 ELEVATION - 3
- -
BRACKET LIGHTING : Optional APP. FABRIC FIN.(TYPE B) FA APP. FABRIC FIN.(TYPE A)
FA - SCALE : 1/60

2. GS ROOM(VBS)
GS(VBS) ELEVATION - 1 2-22
9,400
500 3,500 1,900 3,500

(RR CAMERA) (RT CAMERA)


55

1,000

consult with a construction worker

projector

1,000
(products from supplier)

700 700 700 700 700

1,000
3,020

back screen (fixed by velcro on wire)


3,300

FRONT SCREEN(back screen : fix on the velcro)

1,000
FRONT SCREEN make screenskirts(300mm)
735 1,165
recommend 3~4 degree inclination
Criteria of 'T'
VAR.
280

- - -
APP. FABRIC FIN.(TYPE A) FA FA
APP. FABRIC FIN.(TYPE B) APP. FINISHING MATERIALS FIN. FA

-
APP. FINISHING MATERIALS FIN. FA

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
2. GS ROOM(VBS)
GS(VBS) ELEVATION - 2 GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-23
Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
S

S
S

LEGEND

SYM. NAME SYM. NAME SYM. NAME


2 hole power outlet RGB(HDMI) CABLE
2RC CABLE(speaker)
(220V 15A) (projector)
LAN telephone socket
S sensor cable
( UPT 2 pannels) (intercom)

2. GS ROOM(VBS)
GS(VBS) ELECTRICAL PLAN 2-24
9,400
500 3,500 1,900 3,500
3,400 200 1,350 350
100
LAN CABLE-1EA(products from supplier)
UTP CABLE(sensor cable)-2EA(products from supplier)
RGB CABLE(projector)-1EAproducts from supplier)
2RC CABLE(speaker)-1EA(products from supplier)
55

2 hole power outlet : install side of access hole

1,165
2 hole power outlet : install side of access hole

Criteria of 'T'
SCREEN

2,350
4,700
4,810
4,700

C.L

power outlet : install side of wall(H:350mm)


Criteria of 'T'
telephone socket (intercom H:1200mm)
switch (install on the wall H:1200mm) S

ENT.

1,184
4 hole power outlet : install side of access hole
55

LEGEND

SYM. NAME SYM. NAME SYM. NAME


2 hole power outlet RGB(HDMI) CABLE
2RC CABLE(speaker)
(220V 15A) (projector)
LAN telephone socket
S sensor cable
( UPT 2 pannels) (intercom)

2. GS ROOM(VBS)
GS(VBS) FLOOR ELECTRICAL PLAN 2-25
9,400
500 3,500 1,900 3,500

cable pipe's diameter should be buried on the ground


over 30mm deeply(2RC CABLE ) - 2EA(products from supplier)
cable pipe's diameter should be buried on the ground
over 50mm deeply(RGB CABLE) - 1EA(products from supplier)

S
S RR

S buried on the
cable pipe's diameter should be projector
ground over 20mm deeply(UTP CABLE) - 2EA(products from supplier)

S RT

3,540
4,810
4,700

4,700
CONTROL
BOX

S LT

960
R
cable pipe's diameter should be buried on the ground
over 30mm deeply(RC CABLE ) - 1EA(products from supplier)
S LL

200
S
55

radius of sprinkling water


R2,100 : When the building is not the fireproof
construction
R.2,300 ; When the building is the fireproof
construction

LEGEND

SYM. NAME SYM. NAME SYM. NAME


2 hole power outlet RGB(HDMI) CABLE
2RC CABLE(speaker)
(220V 15A) (projector)
LAN telephone socket
S sensor cable
( UPT 2 pannels) (intercom)

2. GS ROOM(VBS)
GS(VBS) CEILING ELECTRICAL PLAN 2-26
9,400
500 3,500 1,900 3,500

applied for actua circumstance


55

S
RR

RT
4,810
4,700

LT

LL
S
55

radius of sprinkling water


R2,100 : When the building is not the fireproof
construction
R.2,300 ; When the building is the fireproof
construction

LEGEND

SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE SYM. NAME NOTE

cassette type air RR camera cover : SPOT LIGHT


projector CP-F500 S SPEAKER 2EA
conditioner
S air supply 1EA LL
sensor camera
(LED 10W)
3EA
(recommend 2
1EA
RT sensor camera : DOWN LIGHT
access hole 450X450 sprinkler Applied for actual size WAY) R exhaust 1EA sensor camera 8EA
LT (LED 20W)

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
2. GS ROOM(VBS)
GS(VBS) EQUIPMENTS GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-27
Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
30
4,910
50 4,810 50
NUT : weld 3 nuts for supporting top coner

30
30 200 500 500 500 500 500 VAR. 200 30
50

200 30
55

VELCRO

install nut on the basis of left top when look at back side of screen
reinforce for right hander
500

M10 NUT (WELDED TO STEEL PIPE)


M10 NUT (WELDED TO STEEL PIPE)
500

SIDE WALL FINISH:APP. FABRIC PANEL FIN.

back side of screen


500
3,020
3,355
3,300

VELCRO
500

0
10

velcro
WIRE CLIP

TURN BUCKLE
WIRE CLIP
500

TURN BUCKLE
M10 EYENUT
M10 ANCHOR BOLT
VAR.

STEEL ANGLE
M10 ANCHOR BOLT
M10 EYE NUT
280

300

M10 ANCHOR BOLT

2. GS ROOM(DETAIL)
Detail drawing for screen fixing - 1 2-28
M10 NUT (WELDED TO STEEL PIPE)

LIGHT WEIGHT STEEL CONSTRUCTION


THK. 9.5mm GYPSUM BOARD 1PLY
THK. 5mm PLYWOOD 1PLY
500(mandatory)
THK. 5mm PLYWOOD 1PLY
THK.55mm APP. FABRIC PANEL FIN.
THK. 50mm APP. NONFLAMMABLE SPONGE
(after making all-in-one type of panel, then use in the construction site )
APP. NONFLAMMABLE FABRIC FIN.
weld M10 nut with steal pipe
NUT : weld 3 nuts for supporting top coner

rear screen : fix on hexagon nut with wire


front screen : fix on rear screen using velcro
front screen : fix on rear screen using velcro
front screen skirts should be made so as
to cover the slope 300mm
THK. 9.5mm GYPSUM BOARD 2PLY
65mm METAL STUD @450
fix on the pipe frame work which is
(THK. 50mm INSULATION PACKING)
located in the both side

L:300mm coved with rear screenskirts

THK. 6mm ROLL CARPET


THK. 3mm FELT 3PLY
THK.12mm PLYWOOD 1PLY

CONCRETE SLAB
300
280

2. GS ROOM(DETAIL)
Detail drawing for screen fixing - 2 2-29
4,910
50 4,810 50

rear screen
measure the length of nuts' center
(products from supplier)

50 50 100 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 VAR. 50

50
55

front screen

VAR.
consider finishing size, make the size of elevation composition
(products from supplier)

front screen skirts should be made so as to cover the slope 300mm


consider finishing size, make the size of elevation composition ,
150

make it considering the part which comes down back of slope


measure the length from slope's top to center of nut
150

(products from supplier)


150

(products from supplier)


front screen
150
3,020

rear screen

rear screen
3,355
3,300

150

M10 NUT(WELDED TO STEEL PIPE)


150

SIDE WALL FINISH:APP. FABRIC PANEL FIN.


150
150
100 150

install nut on the basis of left top when look at back side of screen
reinforce for right hander
200
280

1 REAR VIEW
- SCALE : 1/30

2. GS ROOM(DETAIL)
Detail drawing for screen fixing - 4(screen) 2-30
(caution : fix to bury behind fabric panel)
M10 NUT(WELDED TO STEEL PIPE) 50 10

29

65

65
50
134

134

134
9

9
5

15
30
55

55

15
65mm METAL STUD @450(INSULATION PACKING) 65mm METAL STUD @450(INSULATION PACKING)
THK. 9.5mm GYPSUM BOARD 1PLY THK. 9.5mm GYPSUM BOARD 1PLY
THK. 5mm PLYWOOD 1PLY SPACER:THK. 15mm PLYWOOD

THK. 5mm PLYWOOD 1PLY THK. 15mm APP. ACOUSTIC PANEL FIN.
THK.55mm APP. FABRIC PANEL FIN.
THK. 50mm APP. NONFLAMMABLE SPONGE
(after making all-in-one type of panel, then use in the construction site )
APP. NONFLAMMABLE FABRIC FIN.

SCREEN 2PLY
(back screen : fix on wire)
(front screen : fix on back screen's velcro)

rear screen area slope hitting area stand by area

2. GS ROOM(DETAIL)
WALL SECTION DETAIL - 1 2-31
LIGHT WEIGHT STEEL CONSTRUCTION LIGHT WEIGHT STEEL CONSTRUCTION
THK. 9.5mm GYPSUM BOARD 1PLY THK. 9.5mm GYPSUM BOARD 2PLY
THK. 5mm PLYWOOD 1PLY APP. PAINT FIN.

THK. 5mm PLYWOOD 1PLY


THK.55mm APP. FABRIC PANEL FIN.
THK. 50mm APP. NONFLAMMABLE SPONGE
(after making all-in-one type of panel, then use in the construction site )
APP. NONFLAMMABLE FABRIC FIN.

FABRIC PANEL(CEILING) ALUMINUM MOULDING


FABRIC PANEL(WALL)

3,020

3,238
3,300

3,300
slope stand by area

65mm METAL STUD @450(INSULATION PACKING) 65mm METAL STUD @450(INSULATION PACKING)
THK. 9.5mm GYPSUM BOARD 1PLY THK. 9.5mm GYPSUM BOARD 1PLY
THK. 5mm PLYWOOD 1PLY SPACER:THK. 15mm PLYWOOD

THK. 5mm PLYWOOD 1PLY THK. 15mm APP. ACOUSTIC PANEL FIN.
THK.55mm APP. FABRIC PANEL FIN.
THK. 50mm APP. NONFLAMMABLE SPONGE
(after making all-in-one type of panel, then use in the construction site )
APP. NONFLAMMABLE FABRIC FIN.

SLOPE LINE

BASE LINE(2mm REVEAL)


280

2
60
2. GS ROOM(DETAIL)
WALL SECTION DETAIL - 2 2-32
controller pipe way(W:500, H:70)

controller accsess hole


1. VISION FA Controller
2. Auto tee up controller swingplate
Criteria of 'T'

bal collector access hole bal collector access hole


1. ball collector 1. ball collector

B
GS Station pipe line(W:150 X H:70)
2-35

A
2-34

make a hole on the ball entrance (W:300XH:100)

2. GS ROOM(DETAIL)
hitting area detail drawing - 1 2-33
100 1,900
CONSTRUCTION PLAN "A" 1,530 370

24
150
pipe way to connet consol

VISION FA Controller AUTO TEE UP


(W:432.2 X D:186 X H:60) Controller
ball collector
(W:403.2 X D:264.5) (W:260 X D:250 X H:65)
600

600
300

552
600
access hole
700

1,530
270 42 1,195 24
83 186 400 100 665 30
ball collector pipe way
1. make a hole : point area apart from 340mm from plate
2. after making a hole, finish with artificial turf
150

3. when finishing with appointed artificial turf : make cuts in the path to prevent interfering movement
4. open the path (1200mm) in case of coming up the access hole

24
secure 500mm for controller pipe way
100

100
200 340 120 180 500 190 370

SECTION "A"
100 1,900
1,530 370

THK. 6mm ROLL CARPET THK. 6mm ROLL CARPET THK. 6mm ROLL CARPET
THK.30mm ACCESS HOLE COVER THK.30mm ACCESS HOLE COVER
THK. 3mm FELT 3PLY THK.12mm PLYWOOD 2PLY THK. 12mm PLYWOOD 2PLY
THK.12mm PLYWOOD 1PLY

CONCRETE SLAB
side : THK. 6mm ROLL CARPET
100

1.5T S'STL H/L


1,530
200

270 42 1,195 24 VOID


50

83 186 400 100 19 150 496 30


50

2. GS ROOM(DETAIL)
hitting area detail drawing - 2 2-34
100 1,900
CONSTRUCTION PLAN "B" 200 1,350 350

200 340 120 180 520 190 350

ball collector pipe way secure 500mm for controller pipe way
480

swing plate rear access hole


300

SECTION "B"
100 1,900
200 1,350 350
(except swingplate finishing ) (except swingplate finishing )
THK. 6mm ROLL CARPET THK. 6mm ROLL CARPET
THK. 12mm PLYWOOD 1PLY THK.48mm ACCESS HOLE COVER THK. 12mm PLYWOOD 1PLY

side : THK. 6mm ROLL CARPET

THK. 6mm ROLL CARPET 1.5T S'STL H/L


THK. 3mm FELT 3PLY
THK.12mm PLYWOOD 1PLY

Criteria of 'T'
CONCRETE SLAB
100
200

OPEN
50

ball collector pipe way(W:120 X H:152) OPEN


controller pipe way (W:500 X H:70)
50

200 340 120 180 520 190 350

V ROOM & VBOOTH INTERIOR GUIDELINE Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any

2. GS ROOM(DETAIL)
hitting area detail drawing- 3 GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-35
Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
5,900

500 3,500 1,900

55

600
600

400

THK.12mm PLYWOOD 1PLY 300


install FELT befre installing carpet
make 300mm gap from outline
4,810

4,700

THK.3mm FELT 3PLY


install to soomth ball's flow and absorb shock
SWING PLATE : APP. ARTIFICIAL TURF FIN.

THK.6mm APP. ROLL CARPET FIN. THK.6mm APP. ROLL CARPET FIN.
install FELT befre installing carpet
make 300mm gap from outline
300
55

2. GS ROOM(DETAIL)
hitting area finishing development 2-36
Interior area when camera is installed
1. before finishing the ceiling, have to check 'T' , then check the location of camera with absolute coordinate
2. make a hole on the confirmed area which is measued by zig with hole cutter

recommended height when camera is installed


1. secure 2,800 mm space from hitting area to ceiling finishing
2. maximum 3,200mm space from hitting area to ceiling finishing( 3,400mm from bottom)
(not exceed 3,200mm to prevent not recognizing of camera sensor)
600

1. allow the stepped cone apart from over 500mm from end of the hitting area
1.club radius from 'T' is over 3,100mm
2.can not install when ceiling height is less than 3,100 mm

0
10
3,
Criteria of 'T'

2. GS ROOM(DETAIL)
ceiling condition description 2-37
1,900 3,500
55

700
ITEM NO. LT-01

1,350
S
MATERIAL 6" DOWN LIGHT

LAMP LED 20W


1,500 1,000
FINISH AL

LT-01 LT-01 COLOR WHITE


LT-01

2,140
300

SIZE 175mm X H220mm


Criteria LOCATION hitting area / stand by area
of 'T'

2,000
4,810
4,700

4,700
700
1,350 LT-01 LT-01

960
R

200
LT-02 LT-02 LT-02 S
55

ITEM NO. LT-02

MATERIAL SPOT LIGHT

LAMP LED 10W

FINISH AL

COLOR WHITE

SIZE

LOCATION stand by area

2. GS ROOM (SPECIFICATION)
GS (VS, VBS) LIGHTING FIXTURE 2-38
ITEM NO. CP-01 ITEM NO. CP-02 ITEM NO. CP-03 ITEM NO. CP-04

MATERIAL SWAN Carpet FO3815 MATERIAL MISSLON CARPET 1012 MATERIAL FORBO _ FORTE 96008 MATERIAL KOLON PCL 1000

SIZE THK.6mm SIZE THK.6mm SIZE THK.6mm SIZE THK.6mm

LOCATION FLOOR _ slope / hitting area (TYPE _ A) LOCATION FLOOR _ slope / hitting area (TYPE _ B) LOCATION FLOOR _ slope / hitting area (TYPE _ C) LOCATION FLOOR _ plate / hitting area

VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE

ITEM NO. TL-01 ITEM NO. TL-02 ITEM NO. MT-01 ITEM NO. PT-01

MATERIAL LEADTEX Amber 003 MATERIAL LG DTE 2905 MATERIAL STAINLESS STEEL HAIR LINE MATERIAL NOROO PAINT EGG SHELL

SIZE 500mm X 500mm SIZE 450mm X 450mm X 3T SIZE THK.1.5mm SIZE -

LOCATION FLOOR _ stand by area (TYPE _ A) LOCATION FLOOR _ stand by area (TYPE _ B) LOCATION FLOOR _ the partition of materials LOCATION WALL _ stand by area (TYPE _2)

VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE -

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
GS (VS, VBS) FINISHES - 1 GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-39
2. GS ROOM (SPECIFICATION) Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
ITEM NO. WD-01 ITEM NO. WD-02 ITEM NO. SH-01 ITEM NO. SH-02

MATERIAL DINGHWA ECOSTEC - ING L7123 MATERIAL DONGHWA ECOSTEC - ING C7123 MATERIAL LG Z:IN CW531 MATERIAL LG Z:IN RS45

SIZE 1280 X 2400 X 15T SIZE 1280 X 2400 X 15T SIZE - SIZE -

LOCATION WALL _ stand by area(TYPE _A) LOCATION WALL _ stand by area (TYPE _B) LOCATION DOOR, FRAME LOCATION BASE, DOOR, FRAME

VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE -

ITEM NO. SH-03 ITEM NO. ETC-01 ITEM NO. ETC-02 ITEM NO. ETC-03

MATERIAL LG Z:IN NW008 MATERIAL roll blind (fire prrof, white) MATERIAL GOLFZON XTS-5000II(exposed type) MATERIAL buried typespeaker

SIZE - SIZE Applied for actual size SIZE 175 X 200 X 280 SIZE

LOCATION FLOOR _ ball collector's rail LOCATION stand by area LOCATION refer to the drawing LOCATION refer to the drawing

VENDOR / FIRM VENDOR / FIRM - VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE - PERSON IN CHARGE - PERSON IN CHARGE - PERSON IN CHARGE -

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
GS (VS, VBS) FINISHES - 2 GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-40
2. GS ROOM (SPECIFICATION) Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
ITEM NO. ETC-04 ITEM NO. ETC-05 ITEM NO. ETC-06 ITEM NO. ETC-07
buffer materials - 50T ENFREE POLYESTER
MATERIAL sprinkler cover MATERIAL install the flat surface on the top MATERIAL ( LIMITED COMBUSTIBLE MATERIAL) MATERIAL door handle K138S (black)

SIZE - SIZE - SIZE SIZE -

LOCATION refer to the drawing LOCATION FLOOR _ slope LOCATION WALL LOCATION DOOR

VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE

ITEM NO. ETC-08 ITEM NO. ETC-09 ITEM NO. ETC-10 ITEM NO. FU-01

MATERIAL MATERIAL fire extinguisher 3.3KG MATERIAL MATERIAL

SIZE - SIZE - SIZE - SIZE -

LOCATION WALL LOCATION FLOOR LOCATION WALL LOCATION FLOOR

VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE


- - -

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
GS (VS, VBS) FINISHES - 2 GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-41
2. GS ROOM (SPECIFICATION) Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.
TYPE - 1 TYPE - 2 TYPE - 3 TYPE - 4 TYPE - 5

A
(POINT)

ITEM NO. FB-A01 ITEM NO. FB-A02 ITEM NO. FB-A03 ITEM NO. FB-A04 ITEM NO. FB-A05

METERIAL F3003 METERIAL F3005 METERIAL F3008 METERIAL F3007 METERIAL F3006

VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE

B
(BASE)

ITEM NO. FB-B01 ITEM NO. FB-B01 ITEM NO. FB-B02 ITEM NO. FB-B02 ITEM NO. FB-B02

METERIAL F3004 METERIAL F3004 METERIAL F3002 METERIAL F3002 METERIAL F3002

VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM VENDOR / FIRM

PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE PERSON IN CHARGE

Documents prepared and presented by GOLFZON Co.,Ltd This document contains information that is privileged and confidential. Any
V ROOM & VBOOTH INTERIOR GUIDELINE
GS (VS, VBS) FINISHES - 3 GOLFZON TOWER SEOUL, 735, Yeongdong-daero, unauthorized disclosure, reproduction, distribution or use of this information 2014.12.24 2-42
2. GS ROOM (SPECIFICATION) Gangnam-gu, Sdoul, 135-953, Korea without express written authorization is strictly prohibited.

You might also like