NR Electric Co., Ltd.

PCS-9611
Feeder Relay

The PCS-9611 relay is a protection, control and monitoring unit


for various applications (such as overhead line, underground
Functions
cable and transformer etc.) on solidly grounded, impedance Protection and Control
grounded, Peterson coil grounded and ungrounded system.
• Six-stage overcurrent protection. (67P, 50P/51P)
The PCS-9611 features a high performance functional library,
Phase overcurrent protection can be controlled by voltage
programmable logic, configurable I/O and integrated frequency-
control element, directional element and harmonic blocking
tracking.
element. IDMT curves complied with IEC and ANSI standard
are provided.
The PCS-9611 is designed based on advanced multiprocessor
platform, fully complying with IEC 61850 station bus & process
• Six-stage neutral/ground overcurrent protection. (67G,
bus, supporting IEC 61850-8-1 MMS, GOOSE and IEC 61850-
50/51G)
9-2 Sampling Value.

Busbar
1
PCS-9611

52
79 25 VTS
3

27 59 47 59G 81U 81O 81R 50DZ


3

50P 51P 67P CTS 49 46 46BC 50BF


1

50G 51G SOTF 67G 37


1

51SG 67SG FDR

Feeder

Figure 1 PCS-9611 Functional Block Diagram

74 Read more on the web


www.nrec.com
NR Electric Co., Ltd.

Up to two groups of neutral (ground) overcurrent protections • Undercurrent protection. (37)


are provided. It can be controlled by harmonic blocking One-stage undercurrent protection is for monitoring a motor
element and directional element. IDMT curves complied with or a capacitor.
IEC and ANSI standard are provided.
• Switch-onto-fault (SOTF) logic.
• Four-stage sensitive earth fault protection. (67SG/51SG) Switch-onto-fault logic is used to clear fault during manually
The sensitive earth fault protection can be controlled by closing or auto-reclosing.
directional element. IDMT curves complied with IEC and
ANSI are provided. • Cold load pickup logic (CLP)
The logic is used to inhibit the selected protective elements
• Two-stage undervoltage protection and two-stage over for an appointed duration, or to increase the settings of the
voltage protection. (27/59) selected protective elements.
The voltage input can select either phase voltage or phase-
to- phase voltage. VT failure blocking is integrated in this • Mechanical Protection
protection. Up to 4 channels for mechanical protection are provided.
It receives the mechanical inputs from a transformer tank
• One-stage negative sequence overvoltage protection. (47) and issues the tripping or alarm outputs with or without time
Negative sequence overvoltage protection could be used to delay.
detect the unbalance situation.
• Interlocking logic for distribution busbar protection.
• Two-stage zero sequence overvoltage protection. (59G) The protection of distribution busbar can be realized via
Zero sequence voltage could be set as external voltage GOOSE communication.
injection or internal calculated voltage.

Feeder Protection
• Remote and local tripping/closing of the breaker.
• Four-stage under-frequency protection, four-stage over- The breaker tripping/closing can be implemented remotely or
frequency protection and four-stage rate-of-change of locally.
frequency (81)
The rate-of-change of frequency could be set as increasing • Interlocking logic of the breaker control.
or decreasing via the setting, as well the duration used for The interlocking logic of the breaker, isolator and earth
rate-of-change calculation is settable. switch is integrated.

• Breaker failure protection. (50BF) • Voltage and current drift auto adjustment.
The relay will initiate re-tripping and adjacent breaker tripping The relay will continually and automatically trace the voltage
during breaker failure. Four logics based on the phase and current drift and adjust the zero point to a normal value.
current and the circuit breaker state is selectable.
• Frequency tracking.
• 4-shot three-pole auto-reclosing with sync-check and dead Frequency tracking is integrated to accommodate the
line/bus check. (79/25) frequency shift in power system.
Synchronism check and dead line/bus check are both
provided for auto-reclosing. • Fault locator.
The relay has an integral fault locator that uses information
• Dead zone protection. (50DZ) from the current and voltage inputs to provide a distance to
Dead zone protection can operate when a fault occurs fault location feature.
between CT and circuit breaker.
Monitoring and Metering
• Negative sequence overcurrent protection (46) • Metering of current, voltage, active power, reactive power,
Two-stage negative sequence overcurrent protection IDMT power factor, energy, frequency, and harmonic.
curves complied with IEC and ANSI are provided.
• Circuit breaker monitoring.

• Broken conductor detection. (46BC) • CT failure supervision.


The ratio of negative-sequence current to positive-sequence
• VT failure supervision.
current (Ι2/Ι1) is used to detect the broken conductor.
• Line voltage failure supervision.
• Thermal overload element. (49)
• Tripping circuit supervision.
This relay provides a thermal overload model using the RMS
value of current. • Self diagnostic.

Read more on the web


www.nrec.com 75
NR Electric Co., Ltd.

• Fault Recorder. • This device constantly measures and calculates a large


amount of analog quantities, such as phase voltage, phase-
• Total 1024 SOE, including tripping, alarm, binary input
to-phase voltage, neutral voltage, phase current, neutral
change and human operation reports.
current, active power, reactive power, power factor and
• Total 64 oscillograms. (Compatible with COMTRADE format) frequency etc.

Communications • The connector type can be selected as plug in/out terminal


• Up to four 10Base-T/100Base-TX (RJ45) ports or two connector or screw terminal connector. The unique plug
100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for in/ out terminal connectors from the relay rear panel to the
non-time-critical message, IEC 60870-5-103 over TCP/IP or terminal blocks on the rack or cabinet makes the onsite
DNP 3.0 commissioning and replacement much easier than the
traditional screw terminals when you do the commissioning.
• Two RS-485 rear ports with IEC 60870-5-103

• Up to Six 100Base-FX ports with IEC 61850-9-2 Sampling • Various methods of GPS time synchronization are supported
Value and GOOSE for time-critical message in this relay, including SNTP, pulse per second (PPS) and
IRIG-B synchronization.
• One RS-485 rear port for clock synchronization

• One RS-232 rear port for printer • This device can communicate with a SAS or RTU via
different communication intermediates: Ethernet network,
• 1 faceplate RJ45 port for testing and setting
RS-485 serial ports. The communication protocol of this
• Clock synchronization via pulse per second, IRIG-B and device is optional: IEC61850, IEC60870-5-103 or DNP3.0.
SNTP
• This device can detect the tripping circuit of the circuit
breaker and monitor the operation (close or trip) time of

Features a circuit breaker by checking the auxiliary contacts of the


circuit breaker.

• Modularized hardware design enables an easy upgrade or


• Complete event recording function is provided: 64 latest
repairs. Various optional function modules can satisfy various
protection operation reports, 1024 latest supervision records,
situations according to the different requirements of users.
1024 latest control operation records, 1024 latest user
operation records and 1024 latest records of time tagged
• This device can sample the analog values from the
sequence of event (SOE) can be recorded.
conventional CT/VT, or receive the sampled values from
electronic CT/VT via merging unit.
• The relay is compatible with multiple protocols- IEC61850
and IEC 60870-5-103 for station bus, GOOSE and
• Overcurrent protection can be controlled by directional
IEC61850-9-2 for process bus.
protection, harmonic blocking element and voltage control
element.
• The setting group can be switched by binary inputs.

• The relay provides optional RTD input module and DC mA


input module for temperature detection.

76 Read more on the web


www.nrec.com

You might also like