Inter ference
prevention function Built-in(S electa ble FREQ.1 or F REQ.2 by ON/OFF button)
(L)
Timer function OFF delay tim er
O FF delay timer(Approx. 40ms fixed) Rotary
(Select able) (Approx. 40ms fixed) encoder
Insulation r esistance Min. 20MΩ(at 500VDC)
Ambient illumination S unlight : Max. 11,000 , Incandescent la mp : Max. 3,000
(M)
Noise strength ± 240V the square wave noise(pulse width:1㎲ ) by the noise simulator 5-Phase
stepping
Dielectric st rength 1,000VAC 50/60Hz for 1 minute motor &
Vibr ation 1.5mm am plitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours Driver &
Controlle
Shock 500m /s ²(50G) in X, Y, Z direction for 3 times
Operating t emperature -10 ~ +50℃ (at non-freezing status)
St or age temperat ure -20 ~ +70℃
Ambient humidity 35 ~ 85%RH
Material Case : Heat-resistant ABS, Case cover : P olycarbonate
Cable ø 4, 4P, Length : 2m ø 4, 6P, Length : 2m
Approval
Weight Approx. 65g
J-48
BF4R Series
▣Control output diagram
BF4R BF4 RP
Fiber optic sensor circuit Connection Fiber optic sensor circuit Connection
(Brown)+V (Brown)+V
Max. 100mA
Load ※
(Black)Control output
(Black)Control output
Load ※ Max. 50mA +
+ (White) 12-24VDC
Max. 100mA 12-24VDC Self-diagnosis -
- Load ※
(White)Self-diagnosis output
output Load ※
(Brown)+V (Brown)+V
Exte rnal
ON inpu t of remote
synch ronization
se nsitivity se tting
input
(Pink) (Pink)
Load ※ OFF input of Load ※
Emission remote sensitivity
disable input ※ se tting ※
(Orange) Load (Orange) Load
+ +
12-24V 12-24V
- DC - DC
(Black) (Black)
Control output Control output
▣Connections
lBF4R lBF4RP
(Brown)+V (Brown)+V
(Black)Control output
Load
(Black)Control output Load + +
(White)Self-diagnosis output
12-24VDC 12-24VDC
(White)Self-diagnosis output - -
Load
Load
(Blue)0V (Blue)0V
lBF4R-E lBF4R-R
J-49
Auto Tuning Setting Type
▣Dimensions Unit:mm
(A)
lProduct Counter
(B)
Timer
12 62 4
(C)
Temp.
controlle
(D)
Power
controlle
16.4 36.5
(E)
Panel
meter
lBracket lBracket
(F)
Tacho/
Speed/
Pulse
meter
12 62 4
(G)
Display
R1.6
16 unit
35 12
14 1 (H)
2 Sensor
controlle
(J)
▣Panel identification Photo
electri c
sensor
F 4
Timer selection switch R External synchronization
4
R NON
NON:Not use timer function
TRIG selection switch (M)
OFD
{ OFD:OFF Delay timer
E GATE
{ TRIG:Trigger synchronization
5-Phase
stepping
motor &
GATE:Gate synchronization Driver &
ON Controlle
ON
J-50
BF4R Series
▣Sensitivity adjustment
◎Ad just ment b y the sensitivity set tin g ◎In case of setting as max. sensitivity
button(All models) ①Set the mode selection switch to [SET] mode.
②In case of Light ON mode : Press ON/OFF button
lLight ON Mode
from ON to OFF without the detecting target.
: The control output turns on at state(Received
(Or set ON input for remote sensitivity setting to
light) and turns off at State(Interrupted light).
Low le vel, and then set OFF input for rem ote
Order Setting method sensitivity setting to Low level)
① Mount the fiber optic cable within detecting distance. In case of Dark ON mode : Press ON/OFF button
SE T
from OFF to ON without the detecting target.
② Change the mode selection switch to [SET]. B
LO CK
(Or set OFF input for rem ote sensitivity setting to
F
(Note) The sensitivity can be set at unstable detecting area. ◎Remote adjustment of sensitivity(BF4R-R)
B F4R-R t ype can adjust the sens itivity with
lDark ON Mode
inputsignal lines regardless of the mode selection
: The control output turns off at State(Received
switch as following diagram;
light) and turns on at State(Interrupted light).
(Brown) +V
<How to set sensitivity >
Most of adjustments except ③ & ⑤ are same as Light (Black) Control output
ON mode. (White) Self-diagnosis output
reflectance)
Interrupte d light Inte rrupted ligh t
②SW2(OFF input of remote sensitivity setting) :
e % state SW2 turns on and then turns off instead of ⑤ method
U Diffuse reflective : Press [OFF]button with the by the sensitivity setting button.
detecting target.
U Through-beam : Press [OFF]button without the <External sensitivity setting input signal condition>
detecting target. State Signal condition
<Through-beam> <Diffuse reflective> High 4.5-30VDC or OPEN
Detecting
mark(a little ON
Low 0-1VDC
reflectance)
Background
8 (much O FF *Input impedance:10kΩ
Interrupte d light Inte rrupted ligh t reflectance)
J-51
Auto Tuning Setting Type
◎External sensitivity setting input prohibition ▣OFF Delay timer function
(BF4R-R)
(BF4R/BF4RP/BF4R-R only) (A)
Counter
Even though mode swit ch is at Lock position,
Standard type(BF4R/BF4RP) and Remote sensitivity
External sensitivity setting input is possible when
setting type(BF4R-R) both contain a built-in approx.
SW1 and SW2 are ON. Therefore please install SW3
40ms fixed OFF-delay timer. The timer works when
in order to prevent sfrom malfunction as below. (B)
the timer selection switch is set to 'OFD'.
*SW3 - OFF : Disable to set external sensitivity Timer
The output turns off after remaining on for additional
*SW3 - ON : Enable to set external sensitivity
40ms at OFF position of the sensing output.
(Brown)+V
It is useful when the response time of the connected (C)
(Black)Control output device is slow or when the sensing signal from a Temp.
(White)Self-diagnosis output controlle
tiny object is too short.
(Pink)ON input of remote sensitivity setting
<Time chart> T≒40ms
(Orange)OFF input of remote sensitivity setting
Sensing Detecting Timer (D)
state
Output Non- selection Power
SW3 detecting switch controlle
operation
(Blue)0V
SW2
Light ON
SW1 LOCK
ON OFF B (E)
F Panel
◎Answer Back function(BF4R-R only) 4 meter
R NON
T
OFF input and stable sensing is not executed, but Dark OF D (G)
ON Display
stable sensing operates after 340ms. ON OFF unit
J-52
BF4R Series
▣Emission disable function(BF4R-E) ▣Interference prevention function
-Operation Test (All models)
lBelow test is available under Light ON state only. BF4R series have a built-in interference prevention
lIf Emission disable input is at Low state, Emission function, two fiber optic cables can be mounted very
light will be disabled. closely by setting different emission frequencies.
lIt can check normal or abnormal state of the sensor
lInterference prevention function
without moving the target.
(Operation of dual frequency mode)
First sensor-F REQ.1(Respo nse time:Max. 0.5ms)
(Orange)Emission disable input
High(OFF)
① ① ① ① OUT OU T
Emission
disable input STAB STAB
Low(ON)
② ② ② OF F OF F
Normal B
Abnor mal F LOCK
※① : Emission area, ② : Emission stopped area 4
※(Note1)If Emission stops, control output must turn on,
Second sensor-FREQ.2(Respon se time:Max. 0.7ms)
but if control output does not turn on, it seems
that sensor has some problems. ①Set the mode selection switch to [SET].
※T≥0.5ms SET
B
(When using interference prevention function T≥0.7ms) F LOCK
※Emission disable input High: 4.5-30VDC or Open 4
Low : 0-1VDC ②Press [ON] & [OFF] buttons for 2sec. at the same time.
③The [STAB] indicator flickers continuously.
▣Self-diagnosis function(All models) ④Press [OFF] button
When fiber tip is covered with dust, there will be ⑤The [STAB] indicator turns off.
reduction in emitted or received light which will cause
the self-diagnosis output to turn on.
※Light ON mode
ON ON
Outer of Move to
M ove to Outer of OUT OUT
unstable a rea unstable a rea unstable a rea
Interrupted unstable a rea
R eceived ligh t OF F
STAB OF F
STAB
light incomplete
incomplete
Sta ble light Flickering
received level
Light off
Sensing Sensing ou tput
condition operation level ⑥Set the mode selection switch to [LOCk].
Stable SET
Inte rrupted B
light leve l
F LOCK
Stability ON
indicator 4
OFF
Control
outpu t
indic ator
L ight ON lInterference prevention function(Operation of
Light OFF
(OUT )
300ms @ 300ms normal mode)
@ ON
Self-
! ! ①Set the mode selection switch to [SET].
dia gnosis OFF
outpu t(Alarm)
②Press [ON] & [OFF] buttons fo r 2 sec. at the same
①The self-diagnosis output turns off during stable sensing. time.
(① position) ③The stable indicator flickers co ntinuously.
②When detecting state remains for 300ms at unstable area ④Press [ON] & [OFF] buttons at the same time.
between stable interrupted light level and stable received ⑤The [STAB] in dicator turns off.
light level, self-diagnosis output turns on, self-diagnosis ⑥Set the mode selection switch to [LOCK].
output turns off at lower than stable interrupted light level ※In case of using interference prevention functio n,
and upper than stable received light level. (② position) hysteresis & resp on se time will b e l ong er than
③When the control output turns on, if an over-current normal operation(respinse time:Max. 0.5ms).
condition exists in control output, then self-diagnosis
output turns on.
J-53