DESIGN OF ONE WAY ROOF SLAB

DESIGN CONSTANTS
FC = 25
FY = 415
SIGMA cbc = 8.5
m = 10.98
Kc = 0.289
SIGMA st = 230
Jc = 0.904
Rc = 1.109
LOAD CALCULATIONS
ASSUMED THK. OF SLAB = 0.125 M
LONG SPAN OF SLAB = 7.4 M
SHORT SPAN OF SLAB = 2.5 M
EFF. SPAN = 2.625 M
DEAD LOAD = 3.125 KN/MM2
LIVE LOAD = 2 KN/MM2
FLOOR FINISH = 1 KN/MM2
TOTAL LOAD = 6.125 KN/MM2
DETERMINATION OF THICKNESS OF SLAB
MOMENT (+VE) = 4.22 KN-M
MOMENT(-VE) = 4.59 KN-M
THK. = 64.37 MM
COVER = 25 MM
DIA OF BAR = 8 MM
OVER ALL THK. REQUIRED = 93.37 MM
CHECK FOR SHEAR
SHEAR FORCE = 8039.06 KN
SHEAR STRESS = 0.125 KN/MM2
PERMISSIBLE STRESS = 0.290 KN/MM2
CHECK = OK
REINFORCEMENT
AREA OF STEEL REQUIRED AT BOTTOM = 162.43 MM2
SPACING REQUIRED = 309.46 MM
SPACING PROVIDED = 300.00 MM
AREA OF STEEL REQUIRED AT TOP = 176.79 MM2
SPACING REQUIRED = 284.32 MM
SPACING PROVIDED = 280.00 MM
DIA OF DISTRIBUTION BAR = 8 MM
AREA OF BAR = 50.24 MM2
AREA OF DISTRIBUTION STEEL = 150 MM2
SPACING REQUIRED = 334.93 MM
SPACING PROVIDED = 250 MM
PROVIDE NOMINAL SHEAR STEEL
SELECT BEAM

PROJECT Support width on Span of slab panel on


Beam Beam Clear Width Depth
No. Name Span (assumed) Right Lef Right Lef
ESR 1 B-1 2.88 0.25 0.300 0.4 0.4 0.000 0.000
ESR 2 B-2 2.60 0.4 0.250 0.3 0.2 0.000 0.000
AEN RES 3 B-3 5.78 0.23 0.450 0.23 0.23 3.000 3.300
AEN RES 4 B-4 3.30 0.23 0.300 0.23 0.23 5.550 4.500
SELECT BEAM ====> 1
1.8

Brick Wall OTHER CHAJJA


Thickness LOAD Main Bottom Internal No of main
of Slab Thickness Height Bar Dia support bars pro.
0 0.00 0.00 2273.83 CHAJJA 16 0 2
0 0.00 0.00 0.00 CHAJJA 12 0 2
0.15 0.00 0.00 16 0 2
0.15 0.00 0.00 12 0 2
200

combination No of comb Dia of top No. of Throu Dia of Extra No. of Extra Ast reqd at Ast pro at
bar dia bars pro. bar bars at top bars at top bars at top bottom bottom
0 0 12 2 0 0 346.63 401.92
0 0 12 2 0 0
16 2 12 2 0 0
12 1 12 2 0 0
Ast reqd No of bars
at top pro at top

QUARTER TYPE

LAXMANGARH
0.00 226.08

FATEHPUR
V AT
BEAM DESIGN OF B-2

DESIGN OF BEAM Beam Name B-2

CLEAR SPAN OF BEAM = 2.88 M


RIGHT SIDE SUPPORT WIDTH = 0.4 M
LEFT SIDE SUPPORT WIDTH = 0.4 M
SPAN OF SLAB PANEL ON RIGHT SIDE = 0.00 M
SPANOF SLAB PANEL ON LEFT SIDE = 0.00 M
THK. OF BRICK WALL OVER BEAM (INCLUDING PLASTER) = 0M
HEIGHT OF BRICK WALL = 0M
THK. OF SLAB = 0M
LIVE LOAD = 200 KG/M2
FLOOR FINISH = 180 KG/M2
DEAD LOAD = 2500 KG/M3
Fck = 30 N/MM2
Fy = 415 N/MM2
SIGMA ST = 230 N/MM2
SIGMA CBC = 10 N/MM2
M = 9.33
Kc = 0.289
Jc = 0.904
Rc = 1.304
WIDTH = 0.250 M
SECTION ASSUMED
DEPTH = 0.300 M

EFFECTIVE SPAN = 3.18 M


LOAD AREA FROM RIGHT SIDE = 0.00 M2
LOAD AREA FROM LEFT SIDE = 0.00 M2
TOTAL LOAD AREA = 0.00 M2

LOAD CALCULATION
SELF WEIGHT OF FLOOR SLAB = 0 KG/M2
TOTAL LOAD ON THE FLOOR SLAB = 380 KG/M2
TOTAL LOAD ON BEAM FROM THE FLOOR SLAB = 0.00 KG/M
SELF WEIGHT OF BEAM = 187.50 KG/M
LOAD FROM BRICK MASONARY = 0.00 KG/M
OTHER LOAD FROM CHAJJA 2273.83
TOTAL LOAD ON BEAM = 2461.33 KG/M

DESIGN BENDING MOMENT


OTHER BEAM IS INTERSECTING 0 = NO
AT SUPPORT = 0.00 KG-M
AT MID SPAN = 3101.47 KG-M
DESIGN BENDING MOMENT (Mu) = 3101.47 KG-M

EFFECTIVE DEPTH REQUIRED = 154.20 MM


MAIN BAR DIA. = 16.00 MM
LINK BAR DIA = 8.00 MM
COVER = 25.00 MM
EFFECTIVE DEPTH AVAILABLE = 267 MM
DEPTH OF BEAM CHOSEN IS OK

STEEL CALCULATIONS
A= b*d*Fck/Fy = 4825.30
B=Mu*b*Fck/(0.87*Fy^2) = 1552434.86
MIN. STEEL REQD. = 0.85*b*d/Fy = 136.72 MM2
STEEL AREA REQUIRED = (A-(A^2-4*B)^0.5)/2 = 346.63 MM2
BAR DIA USED MM 0 16
NO OF BARS RQD 0
+ 2
AREA OF STEEL PROVIDED = 401.92 MM2
BAR DIA AT TOP 12 + 0 MM
No provided 2 0
AREA OF STEEL REQD = 0.00 MM2
NO OF BARS REQD = 226.08 mm2

CHECK FOR SHEAR


SHEAR FORCE = 4923.6 N
SHEAR STRESS = 0.066 N/MM2
% STEEL = 0.536 %
PERMISSIBLE STRESS = 0.501 N/MM2
PROVIDE NOMINAL SHEAR STEEL

BAR DIA USED = 8 MM


SPACING REQUIRED = 302.32 MM
SPACING PROVIDED = 200 MM C/C
RCC design of Lintel Band for AEN Residence Quarter
­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­ ­­­­­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­­­­
LOAD CASES  ­­­­­­­>  ­­­­­­NO ARCH ACTION.­­­­­­
UNITS  ­­­­­­ONE SLAB­­­­­­ Chajja
ONLY LNTL. WITH CHAJA.
­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­ ­­­­­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­­­­
LOAD(TRN) 60 DG.ARCH KG 0.00 0 243.75
LOAD (UDL) KG/M 1954.55 2423.3 200
LOAD (SELF) KG/M 115.00 115 250

CLEAR SPAN  M 1.50 1.50 0.60


SUPPORT WIDTH M 0.23 0.23 0.23
EFF.SPAN OF LINTEL M 1.67 1.67 0.681

BENDING MOMENT KN­M 7.21 8.85 2.51


FACTORED B.M KN­M 10.82 13.27 3.76

Fy N/SQMM 415.00 415 415


Fck N/SQMM 25.00 25 25
­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­ 9.82 6.00 8.41
OVERALL DEPTH  CM 20.00 20.00  10
CHK.FOR DEF.,Mu/BD^2 SAFE SAFE SAFE
CLEAR COVER CM 2.50 2.5 1.5
EFFECTVE DEPTH  CM 17.00 17 8.1
BREADTH CM 23.00 23.00 100.00
­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­
MU/BD^2 1.63 2.00 0.57
A= b*d*Fck/Fy 2355.42 2355.42 4879.52
B=Mu*b*Fck/(.87*Fy^2) 415300.58 509365.54 627177.32

MINI.STEEL REQU. SQ.MM. 80.08 80.08 165.90


STEEL AREA REQUIRED SQ.MM. 191.96 240.89 132.10940226
(A­(A^2­4*B)^0.5)/2
APPENDIX E­1.1 OF IS:456
DIA OF BAR MM 10.00 10 8
NOS. REQD. NOS. 2.44 3.07 3.3
NOS. PROVIDED NOS. 3.00 4 4

% STEEL PROVIDED % 0.60 0.80 0.248


ALLW L/EEE.DEPTH 22.00 21 34
DESIGN OF SHEAR REINFORCEMENT :

SHEAR PRESENT N 15521.63 19037.25 2568.75


FACTORED SHEAR N 23282.44 28555.88 3853.13
NOMINAL SH.STRESS N/SQ.MM 0.60 0.73 0.05

BETA (EQ.FROM SP 16) 4.82 3.61 11.69


 = .8*Fck/6.89*pt
SHEAR STR.OF CONC. N/SQ,MM 0.53 0.59031726 0.3636214944
(EQ.FROM SP 16,4.1) (PROVIDE (PROVIDE (PRO.NOML.
.85*(.8*Fck)^.5*(1+5*BT)^.5 SHR.REIN) SHR.REIN) SHR.REN.)
Dia of shear stirrups 8.00 8 8
LEGGED 2.00 2
fy 415.00 415 415

SPAC.OF STIRP/Dist.REQ. MM. 453.48 453.48  243.00 


SPAC.OF STIRP.PRO. MM. 150.00 150 150
­­­­­­­­­­­­

DIA OF COMP. REIN. MM 8 8 8

d' 33 33 23.00

d'/d 0.19 0.19 0.28

Xu,MAX 8.16 8.16 3.89

Mu,lim 22.93 22.93 22.63

Mu­Mu,LIM ­12.10 ­9.65 ­18.87

fsc 329 329 329.00

Asc ­278  ­222  ­1024 

Ast1 198  468  969 

Ast2 ­197  ­245  ­901 

Ast 1  223  68 


RCC design of Lintel for SE/XEN Residence Quarter
­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­ ­­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­
LOAD CASES  ­­­­­­­>  ­­­­­­NO ARCH ACTION.­­­­­­
UNITS  ­­­­­­ONE SLAB­­­­­­Chajja
ONLY LNTL.WITH CHAJA.
­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­ ­­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­
LOAD(TRN) 60 DG.ARCH KG 0.00 0 243.75
LOAD (UDL) KG/M 2029.55 2573.3 200
LOAD (SELF) KG/M 115.00 115 250

CLEAR SPAN  M 1.50 1.50 0.60


SUPPORT WIDTH M 0.23 0.23 0.23
EFF.SPAN OF LINTEL M 1.67 1.67 0.681

BENDING MOMENT KN­M 7.48 9.37 2.51


FACTORED B.M KN­M 11.21 14.06 3.76

Fy N/SQMM 415.00 415 415


Fck N/SQMM 25.00 25 25
­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­ 9.82 6.00 8.41
OVERALL DEPTH  CM 20.00 20 10
CHK.FOR DEF.,Mu/BD^2 SAFE SAFE SAFE
CLEAR COVER CM 2.50 2.5 1.5
EFFECTVE DEPTH  CM 17.00 17 8.1
BREADTH CM 30.00 30 100
­­­­­­­­­­­­­­­­­­­­­­­­­ ­­­­­­­
MU/BD^2 1.29 1.62 0.57
A= b*d*Fck/Fy 3072.29 3072.29 4879.52
B=Mu*b*Fck/(.87*Fy^2) 561327.36 703651.74 627177.32

MINI.STEEL REQU. SQ.MM. 104.46 104.46 165.90


STEEL AREA REQUIRED SQ.MM. 195.10 249.25 132.1094
(A­(A^2­4*B)^0.5)/2
APPENDIX E­1.1 OF IS:456
DIA OF BAR MM 10.00 10 8
NOS. REQD. NOS. 2.48 3.17 3.3
NOS. PROVIDED NOS. 3.00 4 4

% STEEL PROVIDED % 0.46 0.62 0.248


ALLW L/EEE.DEPTH 24.50 22 34
DESIGN OF SHEAR REINFORCEMENT :

SHEAR PRESENT N 16084.13 20162.25 2568.75


FACTORED SHEAR N 24126.19 30243.38 3853.13
NOMINAL SH.STRESS N/SQ.MM 0.47 0.59 0.05

BETA (EQ.FROM SP 16) 6.28 4.71 11.69


 = .8*Fck/6.89*pt
SHEAR STR.OF CONC. N/SQ,MM 0.47 0.53186564 0.3636215
(EQ.FROM SP 16,4.1) (PRO.NOML.(PROVIDE (PRO.NOML.
.85*(.8*Fck)^.5*(1+5*BT)^.5 SHR.REN.) SHR.REIN) SHR.REN.)
Dia of shear stirrups 8.00 8 8
LEGGED 2.00 2
fy 415.00 415 415

SPAC.OF STIRP/Dist.REQ. MM. 347.67 347.67  243.00 


SPAC.OF STIRP.PRO. MM. 150.00 150 150
­­­­­­­­­

DIA OF COMP. REIN. MM 8 8 8

d' 33 33 23.00

d'/d 0.19 0.19 0.28

Xu,MAX 8.16 8.16 3.89

Mu,lim 29.90 29.90 22.63

Mu­Mu,LIM ­18.69 ­15.85 ­18.87

fsc 329 329 329.00

Asc ­429  ­364  ­1024 

Ast1 198  610  969 

Ast2 ­197  ­378  ­901 

Ast 1  232  68 


DESIGN OF RR STONE MASONARY FOUNDATION F-2

INPUT SHEET
Thichness of wall of Density of super
superstructure x 0.115 m structure wall

Depth of foundation
below ground H 0.6 m Density of soil
Foundation above Density of foundation
ground y 0.6 m wall
Thickness of DPC t 0.15 m Density of D.P.C.
Thickness of PCC y5 0.15 m Density of P.C.C
Soil Bearing Capacity
at given depth 10 T/m2 Height of parapet
Total Number of floors 0 Thckness of parapet

Ht of superstructure
Thickness of roof slab 0.125 m masonary G.F.
Ht of superstructure
Loading on G.F. roof 692.5 Kg/m2 masonary I floor
Ht of superstructure
Loading on F.F. roof 692.5 Kg/m2 masonary II floor
Loading on S.F. roof 0 Kg/m2

Shape of foundation

x 0.115 y 0.6
x1 0.300 t 0.150
o1 0 x1 0.300 y1 0.000
o2 0 x2 0.300 y2 0.000
o3 0 x3 0.300 y3 0.000
o4 0 x4 0.300 y4 0.000
o5 0 x5 0.300 y5 0.650
o6 0.075 x6 0.450 y6 0.300
PCC Offset 0.075 x7 0.600 y5 0.100

base available 0.600 H calculated 0.60


base required 0.41 H available 0.6

Width of foundation at base assumed = 0.600 m


Slab left to footing = 3.800 m
Slab Right to footing = 3.300 m
Load coming from left slab = 1315.75 Kg/m
Load coming from right slab = 1142.63 Kg/m
Total U.D.L. transferred from G.F. R.C.C. roof = 2458.38 Kg/m
Slab left to footing = 0.000 m
Slab Right to footing = 0.000 m
Load coming from left slab = 0.00 Kg/m
Load coming from right slab = 0.00 Kg/m
Total U.D.L. transferred from F.F R.C.C. roof = 0.00 Kg/m
Slab left to footing = 0.000 m
Slab Right to footing = 0.000 m
Load coming from left slab = 0.00
Load coming from right slab = 0.00
Total U.D.L. transferred from S.F R.C.C. roof = 0.00 Kg/m
Total load from roof = 2458.38 Kg/m
2,458.38+0.00+0.00
Unit weight of super-structure masonary = 2000 Kg/m3
Height of parapet wall above masonary = 0.6 m
Thickness of parapet wall = 0.23 m
Load from parapet wall = 276 Kg run m
Height of superstructure masonary = 3.2 m
Thickness of superstructure masonary = 0.115 m
Plaster thickness assumed = 0.02 m
Load from superstructure masonary = 736 Kg run m
Load on footing from superstructure = 3470.38 Kg run m

Unit weight of foundation masonary = 2400 Kg/m3


Volume of foundation masonary above ground = 0.225 m3

Volume of foundation masonary below ground = 0.15 m3


(0.00-0.60)*0.30+0.00*0.30+0.00*0.30 + 0.30*0.00
Volume of PCC = 0.06 m3
0.60*0.100
Unit weight of foundation concrete = 2400 Kg/m3
Gross weight of foundation = 1044 Kg run m
(0.23+0.15)*2,400+0.06*2,400
Net weight of foundation discounting weight of earth removed = 666 Kg run m
0.23*2,400+0.15*(2,400-1,800)+0.06*(2,400-1,800)
Total load transferred on soil = 4136.375 Kg run m
666.00+3,470.38
Pressure intensity = 6.89 T/m2
S.B.C. of the soil strata. = 10 T/m2
Foundation size provided is O.K.
RR STONE MASONARY FOUNDATION F-2

2000

1800

2400
2500
2400

0.6
0.23

3.2
0
0

Check

O.K
O.K
O.K
O.K
O.K
O.K
O.K

m
m
DESIGN OF RR STONE MASONARY FOUNDATION F-3

INPUT SHEET
Thichness of wall of Density of super
superstructure x 0.23 m structure wall

Depth of foundation
below ground H 0.75 m Density of soil
Foundation above Density of foundation
ground y 0.6 m wall
Thickness of DPC t 0.075 m Density of D.P.C.
Thickness of PCC y5 0.15 m Density of P.C.C
Soil Bearing Capacity
at given depth 10 T/m2 Height of parapet
Total Number of floors 0 Thckness of parapet

Ht of superstructure
Thickness of roof slab 0.125 m masonary G.F.
Ht of superstructure
Loading on G.F. roof 692.5 Kg/m2 masonary I floor
Ht of superstructure
Loading on F.F. roof 692.5 Kg/m2 masonary II floor
Loading on S.F. roof 0 Kg/m2

Shape of foundation

x 0.230 y 0.6
x1 0.300 t 0.075
o1 0 x1 0.300 y1 0.000
o2 0 x2 0.300 y2 0.000
o3 0 x3 0.300 y3 0.600
o4 0 x4 0.450 y4 0.300
o5 0 x5 0.600 y5 0.300
o6 0.075 x6 0.750 y6 0.300
PCC Offset 0.075 x7 0.900 y5 0.150

base available 0.900 H calculated 1.05


base required 0.68 H available 0.75

Width of foundation at base assumed = 0.900 m


Slab left to footing = 3.185 m
Slab Right to footing = 3.300 m
Load coming from left slab = 1102.81 Kg/m
Load coming from right slab = 1142.63 Kg/m
Total U.D.L. transferred from G.F. R.C.C. roof = 2245.43 Kg/m
Slab left to footing = 3.185 m
Slab Right to footing = 3.300 m
Load coming from left slab = 1102.81 Kg/m
Load coming from right slab = 1142.63 Kg/m
Total U.D.L. transferred from F.F R.C.C. roof = 2245.43 Kg/m
Slab left to footing = 0.000 m
Slab Right to footing = 0.000 m
Load coming from left slab = 0.00
Load coming from right slab = 0.00
Total U.D.L. transferred from S.F R.C.C. roof = 0.00 Kg/m
Total load from roof = 4490.86 Kg/m
2,245.43+2,245.43+0.00
Unit weight of super-structure masonary = 2000 Kg/m3
Height of parapet wall above masonary = 0.6 m
Thickness of parapet wall = 0m
Load from parapet wall = 0 Kg run m
Height of superstructure masonary = 3m
Thickness of superstructure masonary = 0.23 m
Plaster thickness assumed = 0.02 m
Load from superstructure masonary = 1380 Kg run m
Load on footing from superstructure = 5870.86 Kg run m

Unit weight of foundation masonary = 2400 Kg/m3


Volume of foundation masonary above ground = 0.2025 m3

Volume of foundation masonary below ground = 0.54 m3


(0.00-0.60)*0.30+0.00*0.30+0.60*0.30 + 0.45*0.30
Volume of PCC = 0.135 m3
0.90*0.150
Unit weight of foundation concrete = 2400 Kg/m3
Gross weight of foundation = 2106 Kg run m
(0.20+0.54)*2,400+0.14*2,400
Net weight of foundation discounting weight of earth removed = 891 Kg run m
0.20*2,400+0.54*(2,400-1,800)+0.14*(2,400-1,800)
Total load transferred on soil = 6761.8625 Kg run m
891.00+5,870.86
Pressure intensity = 7.51 T/m2
S.B.C. of the soil strata. = 10 T/m2
Foundation size provided is O.K.
RR STONE MASONARY FOUNDATION F-3

2000

1800

2400
2500
2400

0.6
0

3
0
0

Check

O.K
O.K
O.K
O.K
O.K
O.K
O.K

m
m
DESIGN OF RR STONE MASONARY FOUNDATION F-1

INPUT SHEET
Thichness of wall of Density of super
superstructure x 0.23 m structure wall

Depth of foundation
below ground H 0.6 m Density of soil
Foundation above Density of foundation
ground y 0.6 m wall
Thickness of DPC t 0.15 m Density of D.P.C.
Thickness of PCC y5 0.15 m Density of P.C.C
Soil Bearing Capacity
at given depth 10 T/m2 Height of parapet
Total Number of floors 0 Thckness of parapet

Ht of superstructure
Thickness of roof slab 0.125 m masonary G.F.
Ht of superstructure
Loading on G.F. roof 692.5 Kg/m2 masonary I floor
Ht of superstructure
Loading on F.F. roof 692.5 Kg/m2 masonary II floor
Loading on S.F. roof 0 Kg/m2

Shape of foundation

x 0.230 y 0.6
x1 0.000 t 0.150
o1 0 x1 0.000 y1 0.000
o2 0.075 x2 0.300 y2 0.600
o3 0.075 x3 0.450 y3 0.300
o4 0.075 x4 0.600 y4 0.300
o5 0.15 x5 0.750 y5 0.300
o6 0.1 x6 0.000 y6 0.000
PCC Offset 0.15 x7 0.900 y5 0.150

base available 0.900 1.20


base required 0.66 H available 0.6

Width of foundation at base assumed = 0.900 m


Slab left to footing = 3.300 m
Slab Right to footing = 3.185 m
Load coming from left slab = 1142.63 Kg/m
Load coming from right slab = 1102.81 Kg/m
Total U.D.L. transferred from G.F. R.C.C. roof = 2245.43 Kg/m
Slab left to footing = 3.300 m
Slab Right to footing = 3.185 m
Load coming from left slab = 1142.63 Kg/m
Load coming from right slab = 1102.81 Kg/m
Total U.D.L. transferred from F.F R.C.C. roof = 2245.43 Kg/m
Slab left to footing = 0.000 m
Slab Right to footing = 0.000 m
Load coming from left slab = 0.00
Load coming from right slab = 0.00
Total U.D.L. transferred from S.F R.C.C. roof = 0.00 Kg/m
Total load from roof = 4490.86 Kg/m
2,245.43+2,245.43+0.00
Unit weight of super-structure masonary = 2000 Kg/m3
Height of parapet wall above masonary = 0.75 m
Thickness of parapet wall = 0.115 m
Load from parapet wall = 172.5 Kg run m
Height of superstructure masonary = 3m
Thickness of superstructure masonary = 0.23 m
Plaster thickness assumed = 0.02 m
Load from superstructure masonary = 1380 Kg run m
Load on footing from superstructure = 6043.36 Kg run m

Unit weight of foundation masonary = 2400 Kg/m3


Volume of foundation masonary above ground = 0 m3

Volume of foundation masonary below ground = 0.72 m3


(0.00-0.60)*0.00+0.60*0.30+0.30*0.45 + 0.60*0.30
Volume of PCC = 0.135 m3
0.90*0.150
Unit weight of foundation concrete = 2400 Kg/m3
Gross weight of foundation = 2052 Kg run m
(0.00+0.72)*2,400+0.14*2,400
Net weight of foundation discounting weight of earth removed = 513 Kg run m
0.00*2,400+0.72*(2,400-1,800)+0.14*(2,400-1,800)
Total load transferred on soil = 6556.3625 Kg run m
513.00+6,043.36
Pressure intensity = 7.28 T/m2
S.B.C. of the soil strata. = 10 T/m2
Foundation size provided is O.K.
RR STONE MASONARY FOUNDATION F-1

2000

1800

2400
2500
2400

0.75
0.115

3
0
0

Check

O.K
O.K
O.K
O.K
O.K
Check
O.K

m
m
BEAM DESIGN OF B-1

DESIGN OF BEAM Beam Name B-1

CLEAR SPAN OF BEAM = 3.00 M


RIGHT SIDE SUPPORT WIDTH = 0.2 M
LEFT SIDE SUPPORT WIDTH = 0.2 M
SPAN OF SLAB PANEL ON RIGHT SIDE = 0.50 M
SPANOF SLAB PANEL ON LEFT SIDE = 0.50 M
THK. OF BRICK WALL OVER BEAM (INCLUDING PLASTER) = 0M
HEIGHT OF BRICK WALL = 0M
THK. OF SLAB = 0.15 M
LIVE LOAD = 200 KG/M2
FLOOR FINISH = 180 KG/M2
DEAD LOAD = 2500 KG/M3
Fck = 30 N/MM2
Fy = 415 N/MM2
SIGMA ST = 230 N/MM2
SIGMA CBC = 10 N/MM2
M = 9.33
Kc = 0.289
Jc = 0.904
Rc = 1.304
WIDTH = 0.300 M
SECTION ASSUMED
DEPTH = 0.300 M

EFFECTIVE SPAN = 3.00 M


LOAD AREA FROM RIGHT SIDE = 0.69 M2
LOAD AREA FROM LEFT SIDE = 0.69 M2
TOTAL LOAD AREA = 1.38 M2

LOAD CALCULATION
SELF WEIGHT OF FLOOR SLAB = 375 KG/M2
TOTAL LOAD ON THE FLOOR SLAB = 755 KG/M2
TOTAL LOAD ON BEAM FROM THE FLOOR SLAB = 346.04 KG/M
SELF WEIGHT OF BEAM = 225.00 KG/M
LOAD FROM FLIGHT = 1845.47 KG/M
TOTAL LOAD ON BEAM = 2416.51 KG/M
POINT LOAD FROM SEC BEAM = 1230.67 KG
DESIGN BENDING MOMENT
OTHER BEAM IS INTERSECTING 0 = NO
AT SUPPORT = 4900.25 KG-M
AT MID SPAN = 0.00 KG-M
DESIGN BENDING MOMENT (Mu) = 4900.25 KG-M

EFFECTIVE DEPTH REQUIRED = 193.82 MM


MAIN BAR DIA. = 16.00 MM
LINK BAR DIA = 8.00 MM
COVER = 25.00 MM
EFFECTIVE DEPTH AVAILABLE = 267 MM
DEPTH OF BEAM CHOSEN IS OK

STEEL CALCULATIONS
A= b*d*Fck/Fy = 5790.36
B=Mu*b*Fck/(0.87*Fy^2) = 2943374.37
MIN. STEEL REQD. = 0.85*b*d/Fy = 164.06 MM2
STEEL AREA REQUIRED = (A-(A^2-4*B)^0.5)/2 = 563.08 MM2
BAR DIA USED MM 0 16
NO OF BARS RQD AT TOP 0
+ 3
AREA OF STEEL PROVIDED AT TOP = 602.88 MM2
BAR DIA AT BOTTOM 0+ 12 MM
No provided AT BOTTOM 0 3

CHECK FOR SHEAR


SHEAR FORCE = 7350.4 N
SHEAR STRESS = 0.082 N/MM2
% STEEL = 0.670 %
PERMISSIBLE STRESS = 0.501 N/MM2
PROVIDE NOMINAL SHEAR STEEL

BAR DIA USED = 8 MM


SPACING REQUIRED = 302.32 MM
SPACING PROVIDED = 200 MM C/C
DESIGN OF STAIRCASE (EACH FLIGHT)
HEIGHT OF FIRST FLIGHT = 4000
RISER HEIGHT, R = 200
TREAD WIDTH, T = 178.5
b= (R^2 + T^2)^0.5 = 268.07
NO OF RISERS = 20
NO OF TREADS = 19
SPACE OCCUPIED BY TREADS = 3.3915
LANDING WIDTH = 1
PASSAGE WIDTH = 1.00

DESIGN CONSTANTS
Fck = 30
Fy = 415
SIGMA CBC = 10
MODULAR RATIO = 9.33
SIGMA ST = 230
Kc = 0.289
Jc = 0.904
Rc = 1.304

LOADING ON EACH FLIGHT


THK OF WAIST SLAB = 0.200
EFF. SPAN = 3.592
WEIGHT OF WAIST SLAB = 5000
DEAD WEIGHT OF HORIZONTAL AREA = 7509.00
DEAD WEIGHT OF STEPS = 1900.00
TOTAL DEAD WEIGHT PER METRE RUN = 9409.00
LIVE LOAD = 4000.00
TOTAL LOAD = 13409.00

DESIGN OF WAIST SLAB


BENDING MOMENT = 21620.12
FACTORED BENDING MOMENT (Mu) = 32430.19
EFF. THK OF SLAB REQD = 157.68
COVER = 25.00
BAR DIA = 10.00
ALL OVER THK RQD. = 187.68
PROVIDED THK IS OK
EFFECTIVE THICKNESS PROVIDED = 170

REINFORCEMENT CALCULATION
A= b*d*Fck/Fy = 3294.37
B=Mu*b*Fck/(0.87*Fy^2) = 1740626.80
MIN. STEEL REQD. = 0.85*b*d/Fy = 93.34
STEEL AREA REQUIRED = (A-(A^2-4*B)^0.5)/2 = 660.98
BAR DIA = 10.00
NO. OF BAR RQD = 9
AREA OF DISTRIBUTION STEEL = 240.00
BAR DIA = 10.00
SPACING RQD = 327.08
SPACING PROVIDED = 200.00
DESIGN OF LANDING
WIDTH OF LANDING SLAB = 1
THK. OF LANDING SLAB = 0.230
LOAD TRANSFERRED TO LANDING SLAB = 45476.63
UDL FROM FLIGHT = 45476.63
DEAD LOAD OF LANDING = 5750.00
LIVE LOAD = 2000.00
LOAD FROM BRICK MASONARY = 0.00
TOTAL LOAD = 53226.63
MOMENT = 26613.31
EFFECTIVE THK AVAILABLE = 189.00
EFF.THK RQD. = 186.32
THK. PROVIDED IS OK
BAR DIA = 12
EFFECTIVE THK. = 189.00
AREA OF STEEL = 677.40
NO OF BARS RQD. = 7
N OF STAIRCASE (EACH FLIGHT)
MM
MM
MM
MM

M
M
M

N/MM2
N/MM2
N/MM2
N/MM2
N/MM2

M
M
N/M2
N/M2
N/M
N/M
N/M
N/M

N-M
N-M
MM
MM
MM
MM

MM

MM2
MM2
MM
MM2
MM
MM
MM
M
M
N
N/M
N/M
N/M
N/M
N/M
N-M
MM
MM

MM
MM
SQMM
DESIGN OF STAIRCASE BALCONY TO TOP DOME (EACH FLIGHT)
MAX HEIGHT = 4950
NO OF LANDINGS = 1
HEIGHT OF FIRST FLIGHT = 2600
HEIGHT OF SECOND FLIGHT = 2350
MAX HEIGHT OF FLIGHT FOR DESIGN = 2600
RISER HEIGHT, R = 200
TREAD WIDTH, T = 250
b= (R^2 + T^2)^0.5 = 320.16
NO OF RISERS = 13
NO OF TREADS = 12
SPACE OCCUPIED BY TREADS = 3
LANDING WIDTH = 1
PASSAGE WIDTH = 1.00

DESIGN CONSTANTS
Fck = 30
Fy = 415
SIGMA CBC = 10
MODULAR RATIO = 9.33
SIGMA ST = 230
Kc = 0.289
Jc = 0.904
Rc = 1.304

LOADING ON EACH FLIGHT


THK OF WAIST SLAB = 0.200
EFF. SPAN = 3.200
WEIGHT OF WAIST SLAB = 5000
DEAD WEIGHT OF HORIZONTAL AREA = 6403.12
DEAD WEIGHT OF STEPS = 1900.00
TOTAL DEAD WEIGHT PER METRE RUN = 8303.12
LIVE LOAD = 4000.00
TOTAL LOAD = 12303.12

DESIGN OF WAIST SLAB


BENDING MOMENT = 15748.00
FACTORED BENDING MOMENT (Mu) = 23622.00
EFF. THK OF SLAB REQD = 134.57
COVER = 25.00
BAR DIA = 10.00
ALL OVER THK RQD. = 164.57
PROVIDED THK IS OK
EFFECTIVE THICKNESS PROVIDED = 200

REINFORCEMENT CALCULATION
A= b*d*Fck/Fy = 4628.76
B=Mu*b*Fck/(0.87*Fy^2) = 1514203.97
MIN. STEEL REQD. = 0.85*b*d/Fy = 131.15
STEEL AREA REQUIRED = (A-(A^2-4*B)^0.5)/2 = 354.24
BAR DIA = 10.00
NO. OF BAR RQD = 6
AREA OF DISTRIBUTION STEEL = 240.00
BAR DIA = 10.00
SPACING RQD = 327.08
SPACING PROVIDED = 200.00
DESIGN OF LANDING
WIDTH OF LANDING SLAB = 1
THK. OF LANDING SLAB = 0.240
LOAD TRANSFERRED TO LANDING SLAB = 36909.37
UDL FROM FLIGHT = 36909.37
DEAD LOAD OF LANDING = 6000.00
LIVE LOAD = 2000.00
LOAD FROM BRICK MASONARY = 0.00
TOTAL LOAD = 44909.37
MOMENT = 22454.69
EFFECTIVE THK AVAILABLE = 199.00
EFF.THK RQD. = 171.14
THK. PROVIDED IS OK
BAR DIA = 12
EFFECTIVE THK. = 199.00
AREA OF STEEL = 542.83
NO OF BARS RQD. = 6
ASE BALCONY TO TOP DOME (EACH FLIGHT)
MM

MM
MM
MM
MM
MM
MM

M
M
M

N/MM2
N/MM2
N/MM2
N/MM2
N/MM2

M
M
N/M2
N/M2
N/M
N/M
N/M
N/M

N-M
N-M
MM
MM
MM
MM

MM
MM2
MM2
MM

MM2
MM
MM
MM
M
M
N
N/M
N/M
N/M
N/M
N/M
N-M
MM
MM

MM
MM
SQMM
RCC DESIGN OF
AEN RESIDENCE QUARTER
AT

BARAN

Submitted documents:
- Rcc design documents
- Structural drawing

Submitted to:
SE, PHED CIRCLE, BARAN

Submitted by:
M/S OFFSHORE INFRASTURCTURE LIMITED
& LAHOY BUILDCON LTD. (JV)
DESIGN OF LANDING SLAB

DESIGN CONSTANTS
FC = 20
FY = 415
SIGMA cbc = 7
m = 13.33
Kc = 0.289
SIGMA st = 230
Jc = 0.904
Rc = 0.913
LOAD CALCULATIONS
ASSUMED THK. OF SLAB = 0.2 M
CLEAR SPAN = 1.2 M
EFF. SPAN = 1.2 M
DEAD LOAD = 5 KN
LIVE LOAD = 4 KN
LOAD FROM MASONARY = 15.295 KN/M
FLOOR FINISH = 1 KN
TOTAL LOAD = 25.295 KN
DETERMINATION OF THICKNESS OF SLAB
MOMENT = 18.21 KN-M
THK. = 141.23 MM
COVER = 25 MM
DIA OF BAR = 12 MM
OVER ALL THK. REQUIRED = 172.23 MM
CHECK FOR SHEAR
SHEAR FORCE = 15177.00 KN
SHEAR STRESS = 0.107 KN/MM2
PERMISSIBLE STRESS = 0.23 KN/MM2
CHECK = OK
REINFORCEMENT
AREA OF STEEL REQUIRED = 518.43 MM2
No. of bars reqd = 7.00
DIA OF DISTRIBUTION BAR = 10 MM
AREA OF BAR = 78.5 MM2
AREA OF DISTRIBUTION STEEL = 480 MM2
SPACING REQUIRED = 163.54 MM
SPACING PROVIDED = 215 MM