You are on page 1of 6

Annexure - Electrical Works

S.No DESCRIPTION UNIT QTY RATE (Rs) AMOUNT(Rs) MAKE


Supply Installation Supply Installation
1 ELECTRICAL PANELS

Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V, 4 wire , Free
Standing Floor mounted The INDOOR TYPE IP-54 made out of 14 SWG MS sheet after
seven tank process and painting with Epoxy powder coating. The panel shall consist of
suitable rating TPN Aluminium busbar supported with DMC/ SMC barriers and color coded
with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall
have Short circuit withstanding capacity consist of the switchgear as mentioned below. The
panel shall be got fabricated from manufacturers with CPRI Test certificate only. The size of
all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on 75U
channels including supply and fixing of the same. Every MCCB shall be provided with
ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local
Remote Selector switches shall be provided for controlling the Breakers remotely. All CHAYA
MCCBs shall conform to IEC 60947 (part 1&2), and with adjustable thermal magnetic SWITCHGEARS/UNIT ED
based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall ENGINEERING/AUTO
be over load & short circuit releases with Icu=100% Ics. All CTs/CBCT shall be resin cast SYS/ VKA
type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat POWERMASTER/CP RI
shrinkable kits. Panels shall have form 4b/form 3b construction, Each Feeder with Name APPROVED VENDOR
plate of GI sheet as per the requirement.

a Main Panel Nos 1

b EXHAUST BLOWER PANEL Nos 1


Electrical Control Panel for exhaust blower & scrubber motor of following capacity
shall be 3 phase, 4 wire, 440v, 50hz shall be with DOL/Star Delta, Auto/manual,
starter panel encloser with ON Off,trip Indication lamp, Push button, suitable MCB, view
glass, Internal wiring terminal blocks, ventilation fans, intake air flow. Panel should be
designed for outdoor appication (IP-65). shall have cable entry provision from bottom .
should be suitable for foot mounted sutable incoming feeder of stater for fresh air
blower starter arrangement. the
panel includes the following

c UPS PANEL Nos 1

d APFCR PANEL (210KVAr) Nos 1

e ON/OFF PUSH BUTTON STATION


2 nos of ON/OFF Push button & Indication Lamps with one station/ junction box of Exhaust
Blowers & Scrubbers inside the Chemical laboratory wall / structure / individual structural
stand with all kind of hard wares. The Push button station L&T/LEGRAND/ABB/S
Nos 6 2,750 440 16,500 2,640 CHNEIDER
should have start lockable stop & Push button station.

2 MV CABLES:
Supply of following size 1.1KVgrade XLPE/PVC insulated armoured
Aluminium/Copper conductor cables

a)3.5CX300 SQMM XLPE AL.AR.CABLE( From TX _PCC Panel to Main Panel) Poly cab
Rmt 320 2,230 121 713,504 38,720

b)3.5CX185 SQMM XLPE AL.AR.CABLE( From Main Panel to HVAC Panel-1) Rmt 160 Poly cab
1,441 108 230,560 17,248

c)3.5CX150 SQMM XLPE AL.AR.CABLE( From Main Panel to Exhaust blower Rmt 340 Poly cab
Panel & Hvac Panel-2) 1,139 108 387,090 36,652

d)3.5CX35 SQMM XLPE AL.AR.CABLE(From Main panel to Ro. Vap VTPN DB) Rmt 50 Poly cab
358 55 17,875 2,750

e)3.5X25 SQMM XLPE AL.AR.CABLE(From Main Panel to Utility Panel) Rmt 80 Poly cab
264 44 21,120 3,520

f)4CX16 SQMM PVC CU.AR.CABLE(From Main Panel to DBs & UPS Sysytem) Rmt 600 Poly cab
1,034 33 620,400 19,800

g)4CX6 SQMM PVC CU.AR CABLE (From Main Panel to Lighting DBs & RO Rmt 1000 Poly cab
pumps , STP & 3 phase Sockets) 469 29 468,600 28,600

h)4CX4 SQMM PVC CU.AR CABLE (From Utility Panel Pumps) Rmt 400 325 28 129,800 11,000 Poly cab

i)3CX10 SQMM PVC CU.AR CABLE (From Exhaust Blower Panel to Exhaust Rmt 120 Poly cab
Blower Pumps ) 561 39 67,320 4,620

J)3CX6 SQMM PVC CU.AR CABLE (From Exhaust Blower Panel to Exhaust Rmt 120 Poly cab
Blower Pumps ) 347 29 41,580 3,432

k)3CX2.5 SQMM PVC CU.AR CABLE (From Exhaust Blower Panel to Exhaust Rmt 225 Poly cab
Srcubber Pumps ) 182 26 40,838 5,940

TOTAL 2755186.5 174922


GRAND TOTAL AMOUNT ( SUPPLY +INSTALLATION) 2930108.5
Note : Extra GST
Transport Extra
Payment terms
20% Advance along with work order
50% against pro rate supply of materials
20% against intallation
10% against commissioning
S.No DESCRIPTION UNIT QTY RATE (Rs) AMOUNT(Rs) MAKE
Supply Installation Supply Installation
3 MV CABLE TERMINATIONS:

Providing & Fixing of end terminations for the cable specified Weatherproof
Double compression type steel gland,Bi-metallic lugs using crimping
tool,Insulation tape,Identification tags etc., including end termination and
Earthing of Gland with 8SWG 'GI Wire

a) 3.5CX300 SQMM XLPE AL.AR.CABLE Set 18 1,155 660 20,790 11,880 Bharat / 3D

b) 3.5CX185 SQMM XLPE AL.AR.CABLE Set 4 935 550 3,740 2,200 Bharat / 3D

c) 3.5CX150 SQMM XLPE AL.AR.CABLE Set 10 880 528 8,800 5,280 Bharat / 3D

d) 3.5CX35 SQMM XLPE AL.AR.CABLE Set 4 495 385 1,980 1,540 Bharat / 3D

e) 3.5X25 SQMM XLPE AL.AR.CABLE Set 4 440 330 1,760 1,320 Bharat / 3D

f) 4CX16 SQMM PVC CU.AR.CABLE Set 64 385 275 24,640 17,600 Bharat / 3D

g) 4CX6 SQMM PVC CU AR CABLE Set 24 330 220 7,920 5,280 Bharat / 3D

h) 4CX4 SQMM PVC.CU.AR.CABLE Set 38 275 198 10,450 7,524 Bharat / 3D

i) 3CX10 SQMM PVC.CU.AR.CABLE Set 16 385 275 6,160 4,400 Bharat / 3D

j) 3CX6 SQMM PVC.CU.AR.CABLE Set 8 330 220 2,640 1,760 Bharat / 3D

k) 3CX2.5 SQMM PVC.CU.AR.CABLE Set 18 220 165 3,960 2,970 Bharat / 3D

4 EARTHING
a) Providing and Fixing maintenance free earthing which consists of G.I. Earth 15,180 6,600 121,440 52,800
station,with 600X600X3.15mm GI Plate at 2500mm Depth including construction of
brick pedestal, providing meshed funnel,GI cover and other civil Engineering
works,spreading a homogenous mixture of salt, charcoal aroundthe pipe etc, No 8
completely as per IS 3043, 1987 or latest revision.

b) Providing and Fixing maintenance free earthing which consists of Copper 27,500 7,150 165,000 42,900
Earth station, with 600X600X3mm Copper plate at 2500mm depth including
construction ofbrick pedestal, providing meshed funnel,GI cover and other civil
Engineering works, spreading a homogenous mixture ofsalt,charcoal around the No 6
pipe etc,completely as per IS3043,1987 or latest revision.

c) Supply and laying of following earth strips/ conductors.

i) Supply and fixing of 50 x 6 MM GI Flat Rmt 80 297 88 23,760 7,040

ii) Supply and fixing of 40 x 6 MM GI Flat Rmt 120 248 77 29,700 9,240

iii) Supply and fixing of 25 x 6 MM GI Flat Rmt 1200 149 55 178,200 66,000

iv) Supply and fixing of 40 x 6 MM CU Flat Rmt 80 2,970 88 237,600 7,040

v) Supply and fixing of 25 x 3 MM CU Flat Rmt 60 946 50 56,760 2,970

vi) Supply and fixing of 8Swg GI Wire Rmt 100 330 28 33,000 2,750

vii) Supply and fixing of 6 sqmm Earth Green Wire Rmt 200 95 14 18,920 2,860

5 CABLE TRAY
Supply and Installation of following size 1.6mm thick GI Perforated type cable tray
with Cover Plate and coupler plates, bends, elbows, tees etc as required. The scope
also includes suitable cable tray supports arrangements on walls/Ceiling/Trench
with M.S.Structrual steel / Threaded rods, anchor bolts, As
per Standerd IEC-61537

a) 150 mm width X 50 mm depth X 1.6 mm thickness Rmt 300 660 275 198,000 82,500

b) 200 mm width X 50 mm depth X 1.6 mm thickness Rmt 200 880 440 176,000 88,000

c) 300 mm width X 50 mm depth X 1.6 mm thickness Rmt 220 1,100 495 242,000 108,900

d) 600 mm width X 50 mm depth X 1.6 mm thickness Rmt 100 1,650 660 165,000 66,000

6 PVC CONDUITS
Supply and Wiring with the following size Medium duty FRLS PVC
conduit/Fexible Conduit concealed in wall / ceiling/above false ceiling ,
including junction boxes, bends, elbows & fexible pipes

a)25 mm Dia Rmt 1200 66 28 79,200 33,000

7 LIGHT FIXTURES & FANS


Supply and Installation of following type LED wall/ Surface Mounted/Recessed with
including all fixing accessories etc complete as required.
a) 36W LED (600x 600MM) RECESSED MOUNTED LIGHT (Compton 2,970 660 475,200 105,600
make:LCTLRNE-36-FO-WW, Philips Make : RC380B LED36S -6500 G4 L60 BAJAJ /
Nos 160
W60 PSU OD Bajaj Make:BZRSQL 36W GX ) Cromption

b)20W LED BATTERN LIGHT (Compton make:CCS-100-20-65-HL2-DP- 495 220 22,275 9,900
NWH,Philips Make : BN021C LED20S PSU CW GR S2, Bajaj Make:BCLAB 20W) BAJAJ /
Nos 45
Cromption

c)15W LED ROUND RECESSED MOUNTED LIGHT (Compton make: CDR- 770 220 23,100 6,600
205-15-57-SL-NWHL, Philips Make :SM250C LED12S- 6500 PSU WH, Bajaj BAJAJ /
Nos 30
Make:BPSLR 15W WH ) Cromption

8 EXHAUST FANS
Supply and Installation of following type Fans wall/ Ceiling including all fixing
accessories such as leads,Teak wood round block etc complete as required.

Toilet Exhaust fans with Non-Metallic blades. Nos 5 2,200 330 11,000 1,650 USHA/BAJAJ/
CROMP
TON

9 POINT WIRING
Point Wiring for Light with 1.1KVgrade PVC insulated 3R X 1.5 sqmm FLRS Flexible
Copper conductor wire , run in and including anodised GI Switch box with modular
switchs and the box covered with front plate. along with labling
complete as required.

a)One light point controlled by one 6A switch (consider wiring length 8 meters) Nos 78 825 275 64,350 21,450 LEGRAND/
NORTH-
WEST

b)Two lights point controlled by one 6A switch (consider wiring length 16 meters) Nos 48 990 495 47,520 23,760 LEGRAND/
NORTH-
WEST

c) Three lights point controlled by one 6A switch. (consider wiring length 24meters) Nos 20 1,485 825 29,700 16,500 LEGRAND/
NORTH-
WEST

d)One fan point controlled by one 6A switch(consider wiring length 10 meters) Nos RO 990 385 LEGRAND/
NORTH-
WEST

10 POWER SOCKET (INDEPENDENT)


Supply, erection, testing and commissioning of the following power sockets with
Switch/MCB's and with Flush/wall/surface mounting with front plate , cover and
fixing screws etc complete along with labling complete as required.

a)1 No. of 6/16 Amps, 5-pin Single phase commercial type socket controlled by 534 220 32,010 13,200 LEGRAND/A
1no.s of 6/16 Amps SP Switch. Nos 60 NCHOR

b)2 Nos. of 6/16 Amps, 5-pin Single phase commercial type socket controlled by 825 385 264,000 123,200 LEGRAND/A
2nos. of 6/16 Amps SP Switch. Nos 320 NCHOR

c) 1 No. of 20 A, 240 V, SPN Industrial type socket outlet, with SPN pole and 1,100 330 11,000 3,300 LEGRAND/A
earth, metal enclosed plug top alongwith 16A, “C” curve, SP, MCB, in sheet steel NCHOR
enclosure, on surface or in recess, with chained metal cover for the socket out let Nos 10
and complete with connections, testing and commissioning etc. as required.

d) 1 No. of 32 A, 240V, SPN Industrial type socket outlet, with TPN pole 1,320 385 LEGRAND/A
and earth, metal enclosed plug top alongwith 32A, “C” curve, SP, MCB, in sheet NCHOR
steel enclosure, on surface or in recess, with chained metal cover for the socket out Nos RO
let and complete with connections, testing and commissioning etc. as required.

e) 1 No. of 32 A, 415 V, TPN Industrial type socket outlet, with TPN pole and 4,400 495 LEGRAND/A
earth, metal enclosed plug top alongwith 32A, “C” curve, TP, MCB, in sheet steel NCHOR
enclosure, on surface or in recess, with chained metal cover for the socket out let Nos RO
and complete with connections, testing and commissioning etc. as required.

11 LIGHTING PRIMARY WIRING


Supply and laying with the following size 1.1kV grade FRLS PVC insulated
Copper conductor wire and terminated with suitable lugs complete as required.

a)3 runs of 2.5Sq.mm Wire in existing 25 mm dia conduit from DB to Switch Rmt 2200 110 39 242,000 84,700 POLYCAB
Board.(Primary Wiring)

12 POWER SOCKET CABLING


Supply and laying with the following size 1.1kV grade PVC insulated Copper
conductor Cable and terminated with suitable lugs complete as required.

a) 3C X 4 Sq.mm Cu Flexible cable in existing Cable tray from DB to Rmt 4800 209 44 1,003,200 211,200 POLYCAB
power
sockets.

13 DISTRIBUTION BOARDS
Supply, Installation, Testing and commissioning of TPN Vertical/ Horizontal
MCCB/MCB Distribution boards dust and vermin protected and rated for 415V
Three Phase AC supply operation including incoming MCB as per specifications
and required capacity MCB's shall conform to IS: 8828
a) 8 Way VTPN DB( Horizontal type)with 200A TPN MCCB as incomer and 8 nos 48,950 1,650 146,850 4,950 LEGRAND/
63A 10KA TP MCB's as outgoings (Utility DB) Nos 3

c) 12 Way TPN DB( Horizontal type)with 63A 100mA RCBO as incomer and 36 18,150 1,320 163,350 11,880 LEGRAND/
nos 6-32A as outgoings (UPSDB, PDB Nos 9

D) 8 Way TPN DB( Horizontal type)with 63A 100mA RCBO as incomer and 24 15,400 1,320 92,400 7,920 LEGRAND/
nos 6-32A as outgoings (ELDB LDB) Nos 6

14 SAFETY ITEMS
Supply,Installation,Testing and commissioning of the Following Safety and Fire
fighting accessories as per standards and specification

a) Fire Extinguishers - 4.5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with Nos 2 10,450 440 20,900 880
discharge bend pipe and horn fitted on wall

b).Rubber Mats 415 V, 2 m x 1 m Nos 10 3,300 220 33,000 2,200

c).Shock treatment Chart with wooden frame and glass Nos 1 1,650 165 1,650 165

d).First Aid Box Nos 2 1,650 0 3,300 0

e).415 V Danger Boards Nos 4 605 110 2,420 440

TOTAL AMOUNT 4506645 1283249

GRAND TOTAL AMOUNT ( SUPPLY +INSTALLATION)


5789894