Comparative Statement for Electrotech Engineers


Description RATE AMT
Item
Unit Qty
No.
SH - III : DG Sets
2 Cables
2.1 Installation of Cables
2.2 Cables Termination
Installation & making of end terminations with brass
compression gland and Al. lugs for following sizes of PVC
insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV
grade as required.
2.2.1 3.5 x 240 sq.mm. Each 12 125
Installation and making End termination with brass Single/
Double compression gland including providing and crimping of
aluminum/ copper solderless lugs/ ferrules for XLPE/PVC insulated
armoured power aluminum/ copper conductor cables 1.1 KV grade of
following sizes:
Single Compression Gland for Cu. Cable
2.2.2 8C x 2.5 Sq.mm. Each 4 50
2.2.3 12C x 2.5 Sq.mm. Each 4 50
2.3 Cables Laying
Laying of one number PVC insulated and PVC sheathed
2.3.1 / XLPE power cable of 1.1 KV grade of following size in the existing
RCC/ HUME/ METAL pipe as required.
a Upto 35sq.mm Metre 150 18
b Above 185sq.mm.and upto 400sq.mm Metre 125 69
Laying of one number PVC insulated & PVC sheathed/ XLPE
2.3.2 power cable of 1.1 KV grade of following size in the existing
Masonary open Duct as required.
a Upto 35sq.mm Metre 100 15
b Above 185sq.mm.and upto 400sq.mm Metre 50 60
Laying and fixing of one number PVC insulated and PVC sheathed /
XLPE power cable of 1.1 KV grade of following
2.3.3
size
on wall surface as required.
a Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 12 21
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS 60
b Metre 15
flat clamp)
Laying of one number PVC insulated & PVC sheathed/ XLPE
2.3.4 power cable of 1.1 KV grade of following size on Cable Tray as
required.
a Upto 35sq.mm (clamped with 1mm thick saddle) Metre 50 21
Above 185sq.mm.and upto 400sq.mm (clamped with 1mm thick 90
b Metre 25
saddle)
Total of SH - III : DG Sets
SH - IV : UPS System
1 UPS
Installation, testing and commissioning of 5 KVA UPS, 1 phase input 900
(220 V +15%/ -25%), 1 phase output (220 V + 0.5%) with 30
minutes battery backup. UPS shall be 6 Pulse rectifier + Filter +
1.1 Sets 2
SPWM & IGBT Inverter based system, complete with sealed
mainteneance free lead acid batteries including battery rack and
connecting wires of suitable size as required for each UPS.
Installation, testing and commissioning of 10 KVA UPS, 1 phase 900
input (220 V +15%/ -25%), 1 phase output (220 V + 0.5%) with
30 minutes battery backup. UPS shall be 6 Pulse rectifier + Filter +
1.2 SPWM & IGBT Inverter based system, complete with Sets 1
sealed mainteneance free lead acid batteries including battery rack
and connecting wires of suitable size as required for
each UPS.
Installation, testing and commissioning of 80 KVA UPS, 3 phase 1500
input (415 V +15%/ -25%), 3 phase output (415 V + 0.5%) with
30 minutes battery backup. UPS shall be 6 Pulse rectifier + Filter +
1.3 SPWM & IGBT Inverter based system, complete with Sets 1
sealed mainteneance free lead acid batteries including battery rack
and connecting wires of suitable size as required for
each UPS.
2 Cables
Installation, Laying, Testing and commissioning of following sizes
of FRLS PVC insulated Copper conductor Unarmoured
flexible, overall PVC sheathed 1.1 KV grade cables conforming to
relevant IS code and technical specifications.
2.1 4Cx50 sq mm Metre 85 45
2.2 1Cx35 sq mm Metre 60 24
3 Cable Termination
Installation and making End termination with brass Double
compression gland including providing and crimping of copper
solderless lugs/ ferrules for XLPE/PVC insulated armoured power
copper conductor cables 1.1 KV grade of Following cable sizes.
3.1 4Cx50 sq mm Each 8 120
3.2 1Cx35 sq mm Metre 6 50
Installation, testing and commissioning of following rating and
pole MCCB with thermomagnetic release and terminal spreaders
4
complete with MCCB enclosure including drilling holes in
enclosure cubicle, making connections etc. as required.
4.1 160A, 25kA FP MCCB Each 1 120
Installation and fixing 6 way, single pole and neutral, sheet steel, 210
MCB distribution board, 240 V, on surface/ recess, complete with
tinned copper bus bar, neutral bus bar, earth bar, din bar,
5 Each 2
interconnections, powder painted including earthing etc. as
required. (But without
MCB/RCCB/Isolator)
Total of SH - IV : UPS System
SH - V : VRV AC system
20.1 VRV Panel Wing A (Typical for Wing B)
A INCOMER
1 nos. 500 A TPN MCCB having microprocessor based programmable
i) & variable trip setting for releases with integral protection for the
following:
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF indication Lamps
1 set of Digital Multifunction meter for Voltage, Current, KW,
iii) KWH, KVA & KVAH with selector switch each with 3nos. of 2A SP
MCB & 3nos 500/5A CTs (0-500A) rating
C BUS-BAR
1 Set of 800A TPN Aluminium Bus Bar with heat
i)
shrinkable colour coded PVC Sleeves.
D OUTGOINGS
i) 1 Nos. 100A FP MCCB
ii) 1 Nos. 80A FP MCB
iii) 12 Nos. 63A FP MCB
Installation, Receiving, fixing, testing & commissioning of VRV 500
Sets 2
Panel as described above
20.2 MDB- Emergency Exhaust Panel
A INCOMER
i) 1 No. 200A FP C.O.Switch
ii) 1 No. 200A TPN MCCB (25 KA)
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps
1 set of Digital Multifunction meter for Voltage, Current, KW &
iii) KVA with selector switch each with 3nos. of 2A SP MCB & 3nos
200/5A CTs (0-200A) rating
C BUS-BAR
1 Set of 200A TPN Aluminium Bus Bar with heat
i)
shrinkable colour coded PVC Sleeves.
D OUTGOINGS
i) 4 Nos. 63A TPN MCCB (25 KA)
ii) 8 Nos. 20A/ 32A FP MCB
Installation, Receiving, fixing, testing & commissioning of MDB- 800
Set 1
Emergency Exhaust Panel as described above
20.3 Emergency Exhaust Panel-G (Typ. for Gr. to Sixth Floor)
A INCOMER
i) 1 No. 32A FP MCB
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF indication Lamps
C BUS-BAR
1 Set of 100A TPN Aluminium Bus Bar with heat
i)
shrinkable colour coded PVC Sleeves.
D OUTGOINGS
i) 5 Nos. 10A/ 20A/ 32A TP MCB
4 sets of DOL starter each with self illuminated Push button for
ON & OFF and suitable rating of contactor and O/L relays,
ii) contactors for Auto/ Manual/ Remote operation with selector
switch, suitable for from 1.0 HP to
3.0 HP motor, as required.
Installation, Receiving, fixing, testing & commissioning of 750
Sets 7
Emergency Exhaust Panel-G as described above

20.4 Pressurisation Fans Panel -1 (Typ. for Press. Fans Panel-2 & 3)
A INCOMER
i) 1 No. 63A TPN MCCB (10 KA)
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-Trip indication Lamps
C BUS-BAR
1 Set of 100A TPN Aluminium Bus Bar with heat
i)
shrinkable colour coded PVC Sleeves.
D OUTGOINGS
i) 4 Nos. 10A/ 20A/ 32A TP MCB
3 sets of DOL starter each with self illuminated Push button for
ON & OFF and suitable rating of contactor and O/L relays,
ii) contactors for Auto/ Manual/ Remote operation with selector
switch, suitable for from 4.0 HP to
5.0 HP motor, as required.
Installation, Receiving, fixing, testing & commissioning of 900
Sets 3
Pressurisation Fans Panel -1 as described above

Cables
Cables Laying
Laying of one number PVC insulated & PVC sheathed/ XLPE
22 power cable of 1.1 KV grade of following size on Cable Tray as
required.
22.1 Upto 35sq.mm (clamped with 1mm thick saddle) Metre 1560 21
Cables Termination
Installation & making of end terminations with brass
compression gland and Al. lugs for following sizes of PVC
23
insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV
grade as required.
23.1 3C x 4 sq.mm. Each 186 48
23.2 3C x 6 sq.mm. Each 14 48
23.3 4C x 6 sq.mm. Each 14 56
Double Compression Gland
23.4 4C x 25 Sq.mm. Each 64 90
23.5 3C x 1.5 Sq.mm. Each 137 38
Total of SH - V : VRV AC system
SH- VI : AUTOMATIC FIRE DETECTION AND FIRE ALARM 0
Installation, Testing & commissioning of intelligent analog 150 52500
1. addressable photothermal detector complete with mounting base Each 350
complete as required.
Installation, Testing & commissioning of intelligent addressable 150 300
2. thermal detector with rate of rise cum fixed tempreature Each 2
thermistor complete with base as required.
Installation, Testing & commissioning of addressable beam detector 150 300
with short circuit isolator (inbuilt or seperate) complete with
3. Each 2
emitter and receiver including connections with remote test
features etc complete as required.
Installation, testing & commissioning of fault isolator complete 150 2250
4. Each 15
with base as required.
Installation, Testing & commissioning of addressable manual call 100 2800
5. Each 28
point complete as required.
Installation, Testing & commissioning of addressable fire control 100 1400
6. Each 14
module complete as required.
Installation, Testing & commissioning of addressable horn cum 100 2400
7. Each 24
strobe complete as required.
Installation, Testing & commissioning of response indicator on 50 5000
8. surface/recessed MS Box having two LED, metallic cover complete Each 100
with all connections etc as required.
Installation, testing & commissioning of fire fighter phone jack 50 1250
9. Each 25
complete as required.
Installation, Testing & commissioning of addressable phone 90 2250
10. Each 25
control module complete as required.
Installation, testing & commissioning of fire fighter telephone 31 62
11. Each 2
handset complete as required.
Installation, testing and commissioning of microprocessor based 0
intelligent addressable main fire alarm panel, central processing
unit with the following loop modules and capable of supporting
not less than
240 devices (including detectors) and minimum 120 detectors
per loop and loop length up to 2 km, network communication
card,minimum 320 character graphics/ LCD display with touch
screen or other keypad and minimum 4000 events history log in
12. the non volatile memory (EPROM), power supply unit (230± 5%
V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free
batteries with automatic charger. The panel shall have facility to
connect printer to printout log and facility to have seamless
integration with analog/digital voice evacuation system (which is
part of the schedule of work under SH: PA System) and shall be
complete with all accessories . The panel shall be compatible for
IBMS system with open protocol BACnet/ Modbus over IP
complete as per specifications.
12.1. 10 Loop Panel Each 1 2500 2500
Installation & laying of 2x1.5 sqmm fire alarm armoured cable, 18 90000
600/1000V rated with annealed copper conductor having XLPE
14. Metre 5000
insulation, steel wire armouring & FRLS outer sheath
complete as required.
Installation, Testing & commissioning of 30 1500
15. Each 50
1.5/3/6W metal box ceiling/wall speakers complete as required.
Installation, installation, testing & commissioning of digital audio 30 120
17. amplifier 50 Watt, 25V rms operating at 240 volt AC Installation Each 4
complete as required.
Installation, testing & commissioning of Voice command keypad 6 30 30
19. Each 1
zone, with microphone assembly complete as required.
a speaker cable Single pair, 2-core, 1.5 sqmm Mtr 1000 9 9000
173662.00
SH - IX :IP BASED EPABX AND LAN SYSTEM
1 IT WORKS
Installation and drawing of UTP 4 pair CAT6A LAN cable in the 6 42000
2 Metre 7000
existing surface/ recessed steel/ PVC conduit as required.
4 Copper For Data 0
Installation, testing & commissioning of CAT6A 30 9480
4.5 Each 316
Patch Cord 1mtr for Rack End Side (for Data) Blue Colour
Installation, testing & commissioning of CAT6A Patch Cord 2mtr 30 9480
4.6 Each 316
for User End Side (for Data) Blue Colour
Installation, testing & commissioning of 1U Horizontal Cable 30 480
4.7 Manager, panel with metal grooves, plastic snap on cover with 50 Each 16
patch cord capacity
5 Network Rack DATA/WIFI/Voice 0
Installation, testing & commissioning of 15 U Wallmount Rack 900 900
5.1 Each 1
with all accessories and 06 port PDU
Installation, testing & commissioning of 27 U Wallmount Rack 1200 2400
5.2 Each 2
with all accessories and 12 port PDU
Installation, testing & commissioning of 36U Floor Rack with all 1200 2400
5.3 Each 2
Acessoseris and 12 port PDU
Installation, testing & commissioning of 42U Floor Rack with all 1500 1500
5.4 Each 1
Acessoseris and 12 port PDU
Active Network -DATA (Switches SFP should be from same make) 0
B
Installation, testing & commissioning of 1RU chassis. 48 5000 30000
10/100/1000 BaseT, 2 SFP+ 1G/10G ports, one expansion slot.
7 Each 6
Includes an internal AC power Installation
with a power cord, manuals access card, RJ45 to DB9 adaptor.
9 Installation, testing & commissioning of 10G DAC (Stack) Cable 1m Each 8 100 800
Installation, testing & commissioning of USG (Unified Security 2100 2100
Gateway) - supporting upto 200 users, having Minimum of 4 WAN
11 & 8 (Giga) LAN ports (with Each 1
can be either way configured) - Rack mountable (Propose for
Web blocker licenses as an option).
IP EPABX SYSTEM 0
14.1 4 pair Metre 5600 6 33600
Installation and fixing following modular switch/ socket on the 0
15 existing modular plate & switch box including
connections but excluding modular plate etc. as required.
1.5.1 Telephone socket outlet Each 279 21 5859
TOTAL OF SH - IX :IP BASED EPABX AND LAN SYSTEM 140999
SH- XI: CCTV System
Installation and drawing of UTP 4 pair CAT6A LAN cable in the 6 14400
2 Metre 2400
existing surface/ recessed steel/ PVC conduit as required.
Indoor Dome Camera Supply, 500 21000
Installation, Testing and Commissioning of 2 MP IR Varifocal
Dome Network Camera with 1/2.8" Progressive Scan CMOS,1920
3 Each 42
× 1080@30fps,2.7 to 13.5 mm varifocal lens,Color: 0.01 Lux @
(F1.2, AGC ON),0.018 Lux @ (F1.6, AGC ON), 0 Lux with
IR,H.265+, H.265, H.264+, H.264, Three streams,120dB WDR
Indoor/ Outdoor Bullet Camera Supply, 500 9000
Installation, Testing and Commissioning of 22 MP IR Varifocal
Bullet Network Camera with 1/2.8" Progressive Scan
CMOS,1920 × 1080@30fps,2.7 to 13.5 mm varifocal lens,Color:
4 Each 18
0.01 Lux @ (F1.2, AGC ON),0.018 Lux @ (F1.6, AGC ON),
0 Lux with IR, H.265+, H.265, H.264+, H.264,Three
streams,120dB
WDR
Installation, testing & commissioning of 2 MP Outdoor EXIR 500 2000
Fixed Mini Dome Camera For Lift with 1/2.7" (2 MP)
Progressive Scan CMOS, 1920 x 1080
5 Resolution @ 30 fps, EXIR 2.0 Range Up to 35 ft (10 m), Each 4
2.8 mm and 4 mm Fixed Lens Options, H.265+, H.265, H.264+,
H.264, 120dB True WDR, IP66, IK08
Protection, 12 VDC and PoE (802.3af)
PTZ Camera SITC of minimum 4 Megapixel 1920x1080 IP IR 1500 15000
PTZ camera, 32X optical zoom, WDR, 100 Meters IR
distance, TDN, Defog, DWDR, BLC, AGC, DNR, OSD,
H.264 High Profile dual-stream, ONVIF 2.0, 24 privacy
zones, 255 Preset, Support 8 auto cruise, 5 auto patrol tracks, 5
auto scan,12VAC, Wall Mount, IP-66 Built-in PoE (Power
over Ethernet) eliminates separate power supply and
associated wiring; (12 V DC inputs where PoE power is
7 Each 10
unavailable) complete with Wall mounted outdoor housing
with sunshield, heater and blower etc. all hanging and support
arrangement as required. Item is inclusive of necessary
design, drawing, required connectors, converters and all other
accessories except for items specifically mentioned in
the schedule of quantities of this sub head, to make it
functional as per required standards, all complete as per
direction of Engineer in charge.
NVR 1000 5000
Supply, Installation, Testing & Commissioning of 32 Channel
8 Network Video Recorder with Supported Image Format Set 5
H.264 , H.265, MPEG−4,M−JPEG; N+1
supported with Raid 5
Storage 100 1500
Supply, Installation of Surveillance HDD Storage in NVR:-
NVR storage as required and the storage capable of storing 30 days
recording at 20 fps, minimum 720p resolution, storage should
9 be easily scalable w/o obstructing the functionality of system or Nos 15
losing the data. Full redundancy is required on NVR's and
Storage, Note:-Bidders to provide complete calculation of the
storage to show that total storage is able to provide 30 days
recording at above parameters.
Installation, of NAS for Backup of CCTV Recording with 100 100
Intel® Xeon E3-1245v5 3.5GHz,Quad Core, Hyper Threaded
10 Processor,,Max Turbo Speed 3.9GHz,16GB DDR4 ECC,12 Drive Nos 1
Bays,2x USB3.0,
RAID Levels: 0, 1, 5, 6, 10, Including (10TB X 5 HDD)
Workstation PC 100 200
Supply, installation, Testing and Commissioning of client workstation
consisting of Pentium core i7 processor, 21" colour LCD/LED
11 monitor, 4x2048 MB RAM, 1 TB Hard Disk, DVD Drive, USB Nos 2
Port, Ethernet port, optical mouse, multimrdia keyboard, Latest
Windows OS, Dedicated Graphic Controller including copy in CD
ROM complete with all statndard accessories as required.
Installation, testing and commissioning 43-INCH Color LCD CCTV 100 400
12 Each 4
MONITOR 24x7 operation for viewing complete as required.
Passive Network for CCTV 0
Fibre for CCTV 0
Installation, testing & commissioning of 48 Port 1U 19" Rack 500 500
14 Mount LIU, Drawer type, Fully loaded with SC type Duplex Each 1
Adapters, Splice Tray to accommodate 48 fibers
Installation, testing & commissioning of 12 Port 1U 19" Rack 500 3000
15 Mount LIU, Drawer type, Fully loaded with SC type Duplex Each 6
Adapters, Splice Tray to accommodate 12 fibers
Copper For CCTV 0
Installation, testing & commissioning of CAT 6A RJ 45 Connector 21 2625
18 Each 125
for CCTV
Network Rack For CCTV 0
Installation, testing & commissioning of 9U Wallmount Rack 500 2500
21 Each 5
with all accessories and 06 port PDU
Installation,testing & commissioning of 42U Floor Rack with all 1000 1000
22 Each 1
Acessoseris and 12 port PDU
Total of SH- XI: CCTV System 78225

Grand Total