Grade of Concrete M 25

Grade of Steel Fe 500

S.B.C of the Soil 150 kN/m2

size of the footing (assumed) 1.8 x 2.4 m

Thickness of Footing 300 mm d

Dimentions of column 0.3 X 0.3 m

Depth of the footing 1.75 m

Density of Soil 18 KN/m3

Axial load from the column 81 kN

Moment from the column 50 kNm

Gap between column face and Found 400 mm

Self weight of foundation 32.4 kN

Weight of soil above Foundation (Rec) 110.403 kN

Total load on foundation except Axial Load 142.803 kN

C.G of footing from top 1.2 m

C.G of column from top 0.55 m

C.G of the load from top 0.965 m

Eccentricity from C.G of footing 0.235 m

Moment due to eccentricity 52.65 kNm


Total Load P 223.803 m

Total moment M 102.65 kNm

Ecentricity 0.458662306 M     > 0.4

Maximum Pressure 111.8113926 kN/m2


Safe

Footing Contact 2.224013083 m


Length Top Reinforcement Required

Intensity at 0 kN/m2
other end

Moment Mu 92.17422222 kN/m2

Ast Required 914.9775591 KN‐m

Ast Min 360 mm2

Dia of Bar 12

Spacing of Bar Required 123.6066769 mm


C
Spacing of Bar Provided 110 mm

Ast Provided 1028.16 mm2

Check for Shear
load Coming on Footing Due to Soil & Foundation 33.6 Kn/m

Shear at critical face 15.68833 kN

2
ζv 0.09413 N/mm
pt 0.411

β 7.06

ζc 0.45098 N/mm 2 Safe in Shear

Two Way Shear

Wu 77.70938

Stress Vu 317.5399 kN
2
ζv 0.907257 N/mm

β 1.5

Ks 1

ζc 1.25 N/mm 2 Safe in Shear

Check for Over Turning
Total overturning Moment  102.65 kNm

Resisting Moment
due to Soil Above Footing and foundation weight 171.36 kNm

Factor of Safety 1.5 Safe


0.55

1.2

CG of whole System 2.4


0.235252
CG of Dead Load

250 m

o 1.8

One Way Shear
175.82

250 250

Critical Section 250
For Oneway
Shear 84.16036
2.4

1.85
33.6
Kn/m

1.8
125 125 0.425

125