You are on page 1of 1

Data Teknis Gas Ejector System

2. Gas Ejector System


Type Two stage steam jet ejector
Number of set One (1) set
Suction pressure 0.09 bar abs.
Discharge pressure 0.95 bar abs.
Capacity of gas extraction
Geothermal gas 1,885 Kg/hr
Air 290 kg/hr
Vapor 736 kg/hr
Quantity of cooling water
Inter stage condenser 150 m3/hr
After stage condenser 150 m3/hr
Cooling water temperature 27 oC
Gas temperature at suction 29 oC
Composition of gas extraction system
1 1st stage steam jet ejector
No. of installation Two (2)
Driving steam pressure 6.5 bar abs.
Steam consummtion 5,900 kg/hr
2 2nd stage steam jet ejector
No. of installation Two (2)
Driving steam pressure 6.5 bar abs.
Steam consummtion 4,560 kg/hr
3 intercondenser
Type Direct contac tray condenser
No. of installation One (1)
Shell pressure 0.41 bar abs.
4 After condenser
Type Direct contac tray condenser
No. of installation One (1)
Shell pressure 0.95 bar abs.