Professional Documents
Culture Documents
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 01 Sample 03 Depth(m) 0.27
5
Difference(swell) in mm 6.37
Percentage swell 5.02 18
Proving ring dial reading
TESTING
Proving Ring No. 16
Proving Ring Constant (kN/DIV 0.0212
Penetration of
plunger (mm) Proving Ring Dial Reading 14
0 0
0.5 1
1.0 2
12
1.5 4
2.0 5
2.5 7
10
3.0 8
3.5 9
4.0 10
8
4.5 11
5.0 12
5.5 13
6.0 14 6
6.5 15
7.0 16
7.5 4
8.0
PENETRATION 2.5mm 5.0mm
2
Proving Ring
Dial Reading 7 12
Equivalent kN 0.1484 0.2544 0
x 100 x 100 0 1 2 3 4 5 6 7 8 9
13.2 19.96 Penetration of plunger(mm)
CBR% 1 1
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 01 Sample 03 Depth(m) 0.27
5
SWELL
Initial Dial Gauge Reading 25.07
Final Dial Gauge Reading 28.40 PENETRATION OF PLUNGER Vs PROVING RING DIAL READING
Difference(swell) in mm 3.33
25
Percentage swell 2.62
Proving ring dial reading
TESTING
Proving Ring Constant (kN/DIV 0.0212
Penetration of
plunger (mm) Proving Ring Dial Reading
20
0 0
0.5 1
1.0 3
1.5 6
2.0 8
2.5 13 15
3.0 14
3.5 15
4.0 16
4.5 17
5.0 18 10
5.5 19
6.0 20
6.5 21
7.0 22
7.5
8.0 5
Proving Ring
Dial Reading 13 18
Equivalent kN 0.2756 0.3816 0
0 1 2 3 4 5 6 7 8 9
x 100 x 100
13.2 19.96 Penetration of plunger (mm)
CBR% 2 2
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 01 Sample 03 Depth(m) 0.27
5
TESTING 45
Proving ring dial reading
6.0 39
6.5 40
15
7.0 41
7.5
8.0
10
PENETRATION 2.5mm 5.0mm
Proving Ring 5
Dial Reading 25 37
Equivalent kN 0.53 0.7844
x 100 x 100 0
13.2 19.96 0 1 2 3 4 5 6 7 8
CBR% 4 4 Penetration of plunger (mm)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 01 Sample 03 Depth(m) 0.27
5
Client: Chico Company Limited
Material Existing Offset
Date 8/4/2018 Date 8/4/2018
Responsible Technician: Nassoro J. Checked Eng. J. MATOLO Approved Eng. V. LWANDA
TEST METHOD CML TEST 1.11, ref. BS 1377: Part 4: 1990 and TMH: 1986:A8
Dry Density
(kg/m3)
CBR(%)
1502 1 OMC (%) 12.5
1568 2 MDD(kg/m3) 1865
1682 4 Swell (%) 3.04
10
1
1450 1500 1550 1600 1650 1700
Dry Density (kg/m3)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 02 Sample 03 Depth(m) 0.50
5
Difference(swell) in mm 5.27
Percentage swell 4.15 180
Proving ring dial reading
TESTING
Proving Ring No. 160
Proving Ring Constant (kN/DIV 0.0212
Penetration of
plunger (mm) Proving Ring Dial Reading 140
0 0
0.5 37
1.0 51
120
1.5 80
2.0 92
2.5 96
100
3.0 110
3.5 122
4.0 129
80
4.5 134
5.0 138
5.5 146
6.0 147 60
6.5 151
7.0 155
7.5 40
8.0
PENETRATION 2.5mm 5.0mm
20
Proving Ring
Dial Reading 96 138
Equivalent kN 2.0352 2.9256 0
x 100 x 100 0 1 2 3 4 5 6 7 8 9
13.2 19.96 Penetration of plunger(mm)
CBR% 15 15
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 02 Sample 03 Depth(m) 0.50
5
SWELL
Initial Dial Gauge Reading 26.09
Final Dial Gauge Reading 27.01 PENETRATION OF PLUNGER Vs PROVING RING DIAL READING
Difference(swell) in mm 0.92
160
Percentage swell 0.72
Proving ring dial reading
TESTING
Proving Ring Constant (kN/DIV 0.0212 140
Penetration of
plunger (mm) Proving Ring Dial Reading
0 0
0.5 34 120
1.0 76
1.5 95
2.0 107 100
2.5 115
3.0 123
3.5 129
80
4.0 131
4.5 136
5.0 140
5.5 143 60
6.0 145
6.5 147
7.0 150
40
7.5
8.0
PENETRATION 2.5mm 5.0mm
20
Proving Ring
Dial Reading 115 140
Equivalent kN 2.438 2.968 0
0 1 2 3 4 5 6 7 8 9
x 100 x 100
13.2 19.96 Penetration of plunger (mm)
CBR% 18 15
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 02 Sample 03 Depth(m) 0.50
5
TESTING 400
Proving ring dial reading
0.5 11
1.0 46
1.5 111 300
2.0 173
2.5 220
3.0 251 250
3.5 270
4.0 285
4.5 296 200
5.0 309
5.5 320
6.0 331
150
6.5 339
7.0 343
7.5
100
8.0
PENETRATION 2.5mm 5.0mm
Proving Ring 50
Dial Reading 220 309
Equivalent kN 4.664 6.5508
x 100 x 100 0
13.2 19.96 0 1 2 3 4 5 6 7 8
CBR% 35 33 Penetration of plunger (mm)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 02 Sample 03 Depth(m) 0.50
5
Client: Chico Company Limited
Material Existing Offset
Date 8/4/2018 Date 8/4/2018
Responsible Technician: Nassoro J. Checked Eng. J. MATOLO Approved Eng. V. LWANDA
TEST METHOD CML TEST 1.11, ref. BS 1377: Part 4: 1990 and TMH: 1986:A8
Dry Density
(kg/m3)
CBR(%)
1936 15 OMC (%) 9.3
1981 18 MDD(kg/m3) 2055
2048 35 Swell (%) 0.30
10
1
1920 1940 1960 1980 2000 2020 2040 2060
Dry Density (kg/m3)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 03 Sample 03 Depth(m) 0.30
5
Difference(swell) in mm 0.97
Percentage swell 0.76 30
Proving ring dial reading
TESTING
Proving Ring No.
Proving Ring Constant (kN/DIV 0.0212
25
Penetration of
plunger (mm) Proving Ring Dial Reading
0 0
0.5 4
1.0 5
20
1.5 7
2.0 10
2.5 11
3.0 13
3.5 14 15
4.0 18
4.5 19
5.0 20
5.5 21
6.0 22 10
6.5 23
7.0 24
7.5
8.0
5
PENETRATION 2.5mm 5.0mm
Proving Ring
Dial Reading 11 20
Equivalent kN 0.2332 0.424 0
x 100 x 100 0 1 2 3 4 5 6 7 8 9
13.2 19.96 Penetration of plunger(mm)
CBR% 2 2
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 03 Sample 03 Depth(m) 0.30
5
SWELL
Initial Dial Gauge Reading 26.15
Final Dial Gauge Reading 28.55 PENETRATION OF PLUNGER Vs PROVING RING DIAL READING
Difference(swell) in mm 2.40
35
Percentage swell 1.89
Proving ring dial reading
TESTING
Proving Ring Constant (kN/DIV 0.0212
30
Penetration of
plunger (mm) Proving Ring Dial Reading
0 0
0.5 3
25
1.0 6
1.5 10
2.0 15
2.5 17
20
3.0 19
3.5 20
4.0 22
4.5 23
15
5.0 24
5.5 25
6.0 26
6.5 28
10
7.0 29
7.5
8.0
PENETRATION 2.5mm 5.0mm 5
Proving Ring
Dial Reading 17 24
Equivalent kN 0.3604 0.5088 0
0 1 2 3 4 5 6 7 8 9
x 100 x 100
13.2 19.96 Penetration of plunger (mm)
CBR% 3 3
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 03 Sample 03 Depth(m) 0.30
5
TESTING 70
Proving ring dial reading
10
Proving Ring
Dial Reading 37 59
Equivalent kN 0.7844 1.2508
x 100 x 100 0
13.2 19.96 0 1 2 3 4 5 6 7 8
CBR% 6 6 Penetration of plunger (mm)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 03 Sample 03 Depth(m) 0.30
5
Client: Chico Company Limited
Material Existing Offset
Date 8/4/2018 Date 8/4/2018
Responsible Technician: Nassoro J. Checked Eng. J. MATOLO Approved Eng. V. LWANDA
TEST METHOD CML TEST 1.11, ref. BS 1377: Part 4: 1990 and TMH: 1986:A8
Dry Density
(kg/m3)
CBR(%)
1772 2 OMC (%) 10.1
1800 3 MDD(kg/m3) 2020
1868 6 Swell (%) 2.31
10
1
1760 1780 1800 1820 1840 1860 1880
Dry Density (kg/m3)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 04 Sample 03 Depth(m) 0.30
5
Difference(swell) in mm 0.37
Percentage swell 0.29 20
Proving ring dial reading
TESTING
18
Proving Ring No.
Proving Ring Constant (kN/DIV 0.0212
Penetration of
16
plunger (mm) Proving Ring Dial Reading
0 0
0.5 2
14
1.0 4
1.5 6
2.0 7 12
2.5 9
3.0 10
3.5 11 10
4.0 12
4.5 13
5.0 14 8
5.5 15
6.0 16
6
6.5 17
7.0 18
7.5
4
8.0
PENETRATION 2.5mm 5.0mm
2
Proving Ring
Dial Reading 9 14
Equivalent kN 0.1908 0.2968 0
x 100 x 100 0 1 2 3 4 5 6 7 8 9
13.2 19.96 Penetration of plunger(mm)
CBR% 1 1
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 04 Sample 03 Depth(m) 0.30
5
SWELL
Initial Dial Gauge Reading 17.12
Final Dial Gauge Reading 17.38 PENETRATION OF PLUNGER Vs PROVING RING DIAL READING
Difference(swell) in mm 0.26
40
Percentage swell 0.20
Proving ring dial reading
TESTING
Proving Ring Constant (kN/DIV 0.0212 35
Penetration of
plunger (mm) Proving Ring Dial Reading
0 0
0.5 5 30
1.0 11
1.5 15
2.0 20 25
2.5 23
3.0 28
3.5 29
20
4.0 30
4.5 31
5.0 32
5.5 33 15
6.0 34
6.5 35
7.0 36
10
7.5
8.0
PENETRATION 2.5mm 5.0mm
5
Proving Ring
Dial Reading 23 32
Equivalent kN 0.4876 0.6784 0
0 1 2 3 4 5 6 7 8 9
x 100 x 100
13.2 19.96 Penetration of plunger (mm)
CBR% 4 3
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 04 Sample 03 Depth(m) 0.30
5
TESTING 100
Proving ring dial reading
4.0 56
4.5 61 50
5.0 66
5.5 72
6.0 77 40
6.5 83
7.0 87
30
7.5
8.0
PENETRATION 2.5mm 5.0mm 20
Proving Ring
Dial Reading 41 66 10
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 04 Sample 03 Depth(m) 0.30
5
Client: Chico Company Limited
Material Existing Offset
Date 8/4/2018 Date 8/4/2018
Responsible Technician: Mkumbo P. Checked Eng. J. MATOLO Approved Eng. V. LWANDA
TEST METHOD CML TEST 1.11, ref. BS 1377: Part 4: 1990 and TMH: 1986:A8
Dry Density
(kg/m3)
CBR(%)
1738 1 OMC (%) 6.5
1818 4 MDD(kg/m3) 2110
1935 7 Swell (%) 0.31
10
1
1700 1750 1800 1850 1900 1950
Dry Density (kg/m3)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 05 Sample 03 Depth(m) 0.30
5
Difference(swell) in mm 0.63
Percentage swell 0.50 18
Proving ring dial reading
TESTING
Proving Ring No. 16
Proving Ring Constant (kN/DIV 0.0212
Penetration of
plunger (mm) Proving Ring Dial Reading 14
0 0
0.5 1
1.0 2
12
1.5 4
2.0 5
2.5 8
10
3.0 9
3.5 10
4.0 11
8
4.5 12
5.0 13
5.5 14
6.0 15 6
6.5 16
7.0 17
7.5 4
8.0
PENETRATION 2.5mm 5.0mm
2
Proving Ring
Dial Reading 8 13
Equivalent kN 0.1696 0.2756 0
x 100 x 100 0 1 2 3 4 5 6 7 8 9
13.2 19.96 Penetration of plunger(mm)
CBR% 1 1
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 05 Sample 03 Depth(m) 0.30
5
SWELL
Initial Dial Gauge Reading 28.78
Final Dial Gauge Reading 29.88 PENETRATION OF PLUNGER Vs PROVING RING DIAL READING
Difference(swell) in mm 1.10
30
Percentage swell 0.87
Proving ring dial reading
TESTING
Proving Ring Constant (kN/DIV 0.0212
Penetration of 25
plunger (mm) Proving Ring Dial Reading
0 0
0.5 2
1.0 3
1.5 5 20
2.0 8
2.5 12
3.0 17
3.5 19
15
4.0 20
4.5 21
5.0 22
5.5 23
6.0 24 10
6.5 25
7.0 26
7.5
8.0
5
PENETRATION 2.5mm 5.0mm
Proving Ring
Dial Reading 12 22
Equivalent kN 0.2544 0.4664 0
0 1 2 3 4 5 6 7 8 9
x 100 x 100
13.2 19.96 Penetration of plunger (mm)
CBR% 2 2
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 05 Sample 03 Depth(m) 0.30
5
TESTING 40
Proving ring dial reading
0.5 12
1.0 15
1.5 16 30
2.0 18
2.5 22
3.0 26 25
3.5 29
4.0 30
4.5 31 20
5.0 32
5.5 33
6.0 34
15
6.5 35
7.0 36
7.5
10
8.0
PENETRATION 2.5mm 5.0mm
Proving Ring 5
Dial Reading 22 32
Equivalent kN 0.4664 0.6784
x 100 x 100 0
13.2 19.96 0 1 2 3 4 5 6 7 8
CBR% 4 3 Penetration of plunger (mm)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 05 Sample 03 Depth(m) 0.30
5
Client: Chico Company Limited
Material Existing Offset
Date 8/4/2018 Date 8/4/2018
Responsible Technician: Nassoro J. Checked Eng. J. MATOLO Approved Eng. V. LWANDA
TEST METHOD CML TEST 1.11, ref. BS 1377: Part 4: 1990 and TMH: 1986:A8
Dry Density
(kg/m3)
CBR(%)
1619 1 OMC (%) 10.0
1658 2 MDD(kg/m3) 1970
1776 4 Swell (%) 1.50
10
1
1600 1620 1640 1660 1680 1700 1720 1740 1760 1780 1800
Dry Density (kg/m3)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 07 Sample 03 Depth(m) 0.30
5
Difference(swell) in mm 0.75
Percentage swell 0.59 30
Proving ring dial reading
TESTING
Proving Ring No.
Proving Ring Constant (kN/DIV 0.0212
25
Penetration of
plunger (mm) Proving Ring Dial Reading
0 0
0.5 5
1.0 8
20
1.5 10
2.0 11
2.5 13
3.0 14
3.5 16 15
4.0 17
4.5 19
5.0 20
5.5 21
6.0 22 10
6.5 23
7.0 24
7.5
8.0
5
PENETRATION 2.5mm 5.0mm
Proving Ring
Dial Reading 13 20
Equivalent kN 0.2756 0.424 0
x 100 x 100 0 1 2 3 4 5 6 7 8 9
13.2 19.96 Penetration of plunger(mm)
CBR% 2 2
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 07 Sample 03 Depth(m) 0.30
5
SWELL
Initial Dial Gauge Reading 27.48
Final Dial Gauge Reading 28.26 PENETRATION OF PLUNGER Vs PROVING RING DIAL READING
Difference(swell) in mm 0.78
35
Percentage swell 0.61
Proving ring dial reading
TESTING
Proving Ring Constant (kN/DIV 0.0212
30
Penetration of
plunger (mm) Proving Ring Dial Reading
0 0
0.5 9
25
1.0 16
1.5 22
2.0 23
2.5 24
20
3.0 25
3.5 26
4.0 27
4.5 28
15
5.0 29
5.5 30
6.0 31
6.5 32
10
7.0 33
7.5
8.0
PENETRATION 2.5mm 5.0mm 5
Proving Ring
Dial Reading 24 29
Equivalent kN 0.5088 0.6148 0
0 1 2 3 4 5 6 7 8 9
x 100 x 100
13.2 19.96 Penetration of plunger (mm)
CBR% 4 3
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 07 Sample 03 Depth(m) 0.30
5
TESTING 160
Proving ring dial reading
0.5 22
1.0 53
1.5 73 120
2.0 88
2.5 96
3.0 102 100
3.5 109
4.0 116
4.5 121 80
5.0 125
5.5 129
6.0 133
60
6.5 136
7.0 139
7.5
40
8.0
PENETRATION 2.5mm 5.0mm
Proving Ring 20
Dial Reading 96 125
Equivalent kN 2.0352 2.65
x 100 x 100 0
13.2 19.96 0 1 2 3 4 5 6 7 8
CBR% 15 13 Penetration of plunger (mm)
TANZANIA RURAL AND URBAN ROADS AGENCY
CBR TEST
Project: Tanzania Strategic Cities Project Package Ch: (km) Pit 07 Sample 03 Depth(m) 0.30
5
Client: Chico Company Limited
Material Existing Offset
Date 8/10/2018 Date 8/10/2018
Responsible Technician: Nassoro J. Checked Eng. J. MATOLO Approved Eng. V. LWANDA
TEST METHOD CML TEST 1.11, ref. BS 1377: Part 4: 1990 and TMH: 1986:A8
Dry Density
(kg/m3)
CBR(%)
1752 2 OMC (%) 10.0
1815 4 MDD(kg/m3) 2028
1969 15 Swell (%) 0.51
10
1
1700 1750 1800 1850 1900 1950 2000
Dry Density (kg/m3)