You are on page 1of 14

1/20/14 Tur n off the i nver ter pr otection

 Сегодня: 20 января 2014 г. Понедельник 10:13:42

Home
How to remove the inverter
Theory Electronics

Theory.
heory. Basics
protection
Repair of practice
Several ways
w ays to disable protec
protection
tion in popul
popular
ar PWM
Reference
Reference data
dat a
controllers inverters
inverters LCD.
Calculators online

Site Search Caution:


Yandex
Yandex Not all methods
methods tested journalist
journalist and can
ca n not
not be recommended repairers
rep airers
Schematic diagrams,
Schematic who
wh o d
 do
o not hav
have suff
 suffici
icieent experience
experience and
 and theoretical
theoretical knowledge.
free
If anyon
anyone  broke and
and TV show
shows, we rec
recomme
ommend
nd this link: - TV not included
Catalog
Catalog wiring diagrams,
diagrams,
articles
articl es o n electron
electronics,
ics,
help forum. W hen
hen repair a
repair and
nd diagno
diagnostics,
stics, it
i t is often
ofte n necessary to check
rlocman.ru individual circuits of the inverte
i nverterr circuit -
circuit - power converte
converterr
How to live easily
How to easily backlight LCD panel. To make the necessary measurements
and happily,
and happily, sometimes
someti mes fails
fail s generation breaks
breaks for various
various reasons, for
example because Skewed loads.
effortlessly
effortlessly fulfill their 
desires! Training course. Together masters and researches various repair forums were
pavel-kolesov.ru offered several options
opti ons for blocking inverter
inverter protecti
protection
on in
order to be able to diagnose.
English for six
English
months!
mon ths! Readers
Readers ar a re inv
i nvit
ited
ed to several previously
previously published
Secret method of teaching examples of how to disable the protection of the inverter for
intelligence officers. Learn
from home!
the following ШИМ-контроллеров: AT1741 AT1741 , , BA9741
A9741 , ,
spyenglish.ru
spye nglish.ru BD9240 ,
BD9240  , BD9883
BD9883 ,  , BD9897FS
BD9897FS , , BIT3102A
BIT3102A ,  , BIT3193
BIT3193 ,
 ,
BIT3713 ,
BIT3713  , INL837GL
INL837GL ,  , FAN7311
FAN7311 ,
 , FAN7314
FAN7314 ,  , KH0803A
KH0803A ,  ,
English for six LX1691A ,
LX1691A  , MAX8722
MAX8722 ,  , MP10072E
MP10072E ,  , MP1008
MP1008 , , MP1009
MP1009 , ,
months! MP1027EF ,
MP1027EF  , MP1038
MP1038 ,  , MSC1692
MSC1692 , , OZ960
OZ960 , , OZ964
OZ964 ,  ,
Secret method of teaching OZ9910GN ,
OZ9910GN  , OZ99361
OZ99361 ,  , OZ9938Q
OZ9938Q ,  , OZ9966SN
OZ9966SN ,  , OZT1060GN
intelligence officers. Learn
from
from hom e!
, SEM2006
SEM2006 ,  , SEM2105
SEM2105 ,  , SP5005
SP5005 ,
 , TA9687GN
TA9687GN ,  , TL1451
better-life.ru

Inverter 
Prices
Prices on welding OZ960
ma chines, units,
units, sem i-
automatic. Prices.
rs-metal.ru To disable input SoftStart (pin 4 chip OZ960), you need to
force apply to this input (pin 4) voltage 1,5 V - 3,5 V, which
will manage the duration of the PWM and adjust the output
current in the lamps.
Information courtesy of the party Rottor at the repair forum
http://monitor.net.ru

tel - spb.r u/inv_za.html#OZ9966SN 1/14


1/20/14 Turn off the inverter protection

Another original solution unprotect OZ960 on pin-10 from


the participant AMIT: Quote:

0Z960
very simple way to remove the protection.
put LED from 10 feet on the ground. (6 foot chip)

OZ964

From the forum participant monitor.net.ru KRAB Quote:

Removing protection for OZ964:


 At pin 4 (SST - Soft-Start Time) at the moment when you need to keep the
1,8 - 2V.

tel-spb.ru/inv_za.html#OZ9966SN 2/14
1/20/14 Turn off the inverter protection

From the forum participant monitor.net.ru X1-42 Quote:

OZ964 protection is released as well as OZ960, 10 LED output.

BIT3193

Information provided by the participant KRAB: Quote:

Removing protection for BIT3193:


When protection voltage on pin 5 of about 3, 5 V.
When the voltage on pin 5, from 0.4 to 2.4V and the command "start"
PWM operates autonomously, the lamp does not turn off.

tel-spb.ru/inv_za.html#OZ9966SN 3/14
1/20/14 Turn off the inverter protection

TL1451

More information on the KRAB: Quote:

Unprotect TL1451:
- Blocking protection chip TL1451 (analogue VA9741) reduces to the
simple action of the output circuit 15 on the "ground."
But if it is done after a trip (eg forceps), nothing happens because the
trigger is already locked protection from feedback sensors ties.
- to restore the functionality you need to reset the trigger protection
switching off and on of the inverter or the level changes at the conclusion 9
chips.
During operation, the monitor reset trigger protection is automatically
updated.

FAN7314

From the forum participant monitor.net.ru Valentin Quote:

BN44-00182C with live transformers with the inverter, decided to throw all
trances known ... 123rd unit, a primary trans paralleled,
and on foot 1yu FAN7314 put zener 4.3v with 5 to 620 ohm resistor and
the housing.

tel-spb.ru/inv_za.html#OZ9966SN 4/14
1/20/14 Turn off the inverter protection

FAN7311 - FAN7314

By participant monitor.net.ru Parazetam0l Quote:

Controllers FAN7311 - FAN7314


Following the procedure Valentin, (on this page) - 560 ohm resistor from
pin 1 to ground.
Zener diode is not needed, then turned it still does not work.

MP1008

Information provided by the participant ancl: Quote:

Removing protection from MP1008: 10K with 4 pins on the housing


MP1008.

tel-spb.ru/inv_za.html#OZ9966SN 5/14
1/20/14 Turn off the inverter protection

OZ9938Q

Information provided by the participant JUDI71: Quote:

... removed sewn, 10k parallel Conder 3 pin OZ9938.

AT1741

Information provided by the participant asanik: Quote:

 AT1741S - LED display with 15 on the ground. I believe it is possible and


resistor.
LED off.

tel-spb.ru/inv_za.html#OZ9966SN 6/14
1/20/14 Turn off the inverter protection

BD9897FS

Information provided by the participant comporator: Quote:

 Apparatus LCD Sharp LC-32A47l, inverter 6-lamp on BD9897FS. It was


necessary to circumvent the protection BD9897FS, trance korotnula one
of vtorichek - winding deleted. Long tried to do something on the
feedback did not work. As a result, put forward the LED is turned on pin
17 BD9897 and body that immediately shut off protection. Unit earned run
and successfully issued.

TA9687GN

Information provided by the participant gchel: Quote:

TA9687GN ---- connect 12 TIMER output through 47kom with Copus


(parallel S818). Checked.

BD9883

Information provided by the participant AMIT: Quote:

you can use any LED 13 foot-SS, IC BD9883, --- anode enclosure ---- 7,
tel-spb.ru/inv_za.html#OZ9966SN 7/14
1/20/14 Turn off the inverter protection

cathode
or just sit on the ground 12 foot.

Information provided by the participant Captain: Quote:

 just sit on the ground 12 foot.


recommendation from Sharp.

OZ99361

Information provided by the participant Nlfjk: Quote:

Disabling security in the chip OZ99361.


... regulator set the voltage at pin 1 of the chip within the sustainable
launch 1,85 - 1,98 V

By participant monitor.net.ru kebastos Quote:

Supplement and I on LG 26LC2RA ..... panel LC260WX2, master-slave


inverter, assembled jack OZ99361 ..... and can be changed at 9936, but
it's not in it .... after the inverter is cut by three seconds ...... off its
protection invented and there in the internet: see photo below .....
(Shutdown protection in this case is not dangerous for the inverter is cut
because podsevshih lamps) .... but! When finalizing such it works very
well, but every mode of "standard" and AV1 inverter starts to squeal like a
dog incised at this working ....... my little alteration other - hang in the air 
one paw micro and connect it through rezik 100K 5 volts .... the figure is
clay, going 6-foot Micra .... well, 1 foot between the micro-and the ground -
konderchik 0.15 microfarads, and all - works great silence in all modes

OZ9910GN

Information provided by the participant evg4682: Quote:

QZ9910 GN controller protection is disabled: LED with 3 foot stabistorov.


Works with one lamp is regulated only contrast. Monitor Aser al1716.

Discussion t opics participants monitor.net.ru as unprotect


inverter to TL494

tel-spb.ru/inv_za.html#OZ9966SN 8/14
1/20/14 Turn off the inverter protection

More options from other forums:

BIT3102A

By participant monitor.espec.ws zuev-tv Quote:

For inverters BIT3102A = disable security setting on pin 6 voltage 2.5 V.

OZ9966SN

By participant monitor.espec.ws zuev-tv Quote:

Inverter LCD TV on OZ9966SN - how to disable protection.

LX1691A
tel-spb.ru/inv_za.html#OZ9966SN 9/14
1/20/14 Turn off the inverter protection

By participant monitor.net.ru gosha_gor Quote:

I want to share deprotection inverter IC type LX1691A: Dana 14 foot chip


called as OP-SNS grounded to the chassis. Works OK.

MP1009

By participant monitor.net.ru Benzopiren Quote:

Disabling security MP1009 - Jumper pin 5 on the body.

OZT1060GN

By participant monitor.net.ru bdvrt Quote:

OZT1060GN - sv.diod pin1

QZ9938GN

By participant monitor.net.ru bdvrt Quote:

QZ9938GN - sv.diod pin3 ... for bit3193

MP10072E

By participant monitor.net.ru gosha_gor Quote:

Removing protection IC type MP10072E: 3 pin - LED on the body.

INL837GL

By participant monitor.net.ru Benzopiren Quote:

INL837GL Stabilize power to pin 12 - 1.7 - 2 V. Connect stabistorov


tel-spb.ru/inv_za.html#OZ9966SN 10/14
1/20/14 Turn off the inverter protection

(LED) display with 12 on the ground, there is supply power from the
source 5 V through a resistor 470 - 510 ohms.

OZ99361

By participant monitor.net.ru kebastos Quote:

Supplement and I on LG 26LC2RA ..... panel LC260WX2, master-slave


inverter, assembled jack OZ99361 ..... and can be changed at 9936, but
it's not in it .... after the inverter is cut by three seconds ...... off its
protection invented and there in the internet: see photo below .....
(Shutdown protection in this case is not dangerous for the inverter is cut
because podsevshih lamps) .... but! When finalizing such it works very
well, but every mode of "standard" and AV1 inverter starts to squeal like a
dog incised at this working ....... my little alteration other - hang in the air 
one paw micro and connect it through rezik 100K 5 volts .... the figure is
clay, going 6-foot Micra .... well, 1 foot between the micro-and the ground -
konderchik 0.15 microfarads, and all - works great silence in all modes

MP1038

Quote:

... deprotection MP1038 - 6th leg driver (FT) through 10k on the body. (By
analogy with the MP1008, only there FT - 4th leg)
-
Sergei Ganz
tel-spb.ru/inv_za.html#OZ9966SN 11/14
1/20/14 Turn off the inverter protection

BIT3713

By participant monitor.net.ru asanik


Quote:

BIT3713 - LED with 5 O TIMER on the ground. LED is not lit.

BA9741

By participant monitor.net.ru asanik


Quote:

BA9741 F 15 pin - SCP connected to the "ground." Thus protection is


blocked on both channels driver. (LCD CAMERON 1501SP)

SEM2105
tel-spb.ru/inv_za.html#OZ9966SN 12/14
1/20/14 Turn off the inverter protection

By participant monitor.net.ru ra4llb


Quote:

SEM2105 - to lock put LED on pin 1 of IC.

MAX8722

By participant monitor.net.ru ANOD07


Quote:

max8722 - to 4-pin lock put on the ground.

SEM2006

By participant monitor.net.ru yuri 72


Quote:

SEM2006 - Protection LED is removed from pin 2 to ground.

MSC1692

By participant monitor.net.ru yuri 72


Quote:

MSC1692 - 4 pin resistor 220kOm on the body.

KH0803A

By participant monitor.net.ru yuri 72


Quote:

KH0803A - LED or R 390 - 820 kOm with 5 pins on the body. (Parallel to
the N125).

SP5005

By participant monitor.net.ru Altai


Quote:

SP5005 - (sop16 4ccfl) LED 5 (timer) on the pin in my case


tel-spb.ru/inv_za.html#OZ9966SN 13/14
1/20/14 Turn off the inverter protection

korpus.OZ9910 disable protection LED with 10 pins (not to 9th)

MP1027EF

By participant monitor.net.ru Rishat-80


Quote:

 Another way to disable protection PWM controller MP1027EF. Rare


controller generally installed in industrial firms monoblocks ADVANTECH.
PWM controller with a 20-pin, 16-pin should be connected to GND
through a red LED.

BD9240

By participant monitor.net.ru jurez


Quote:

BD9240 Unprotect possible by planting 15 foot (CP) through 10k to work


korpus.Perestaet backlight adjustment panel.

Comments and suggestions made at horeff@mail.ru

tel-spb.ru/inv_za.html#OZ9966SN 14/14

You might also like