Professional Documents
Culture Documents
Detroit Diesel Series 60 DDEC II To DDEC IV Conversion 18SP546 PDF
Detroit Diesel Series 60 DDEC II To DDEC IV Conversion 18SP546 PDF
In order for the newly installed DDEC IV ECM to be For example, there is only one DDEC IV rating released
programmed, a mainframe file must be established. To for the 11 liter engines: 6N4D7275 is a 400/357 @
ensure that the ability to program the DDEC IV ECM is 1800/2100-1350 lb·ft.
established, the attached FAX form (See Figure 5) must
be filled out and sent to the DDC Customer Support To reduce the maximum torque from 1350 to 1250 lb·ft:
Center at (313) 592-5888. See Table 2 for the • Set the low gear torque limit to 1250
appropriate 6N4D and 6N4M groups. • Set the threshold to 0.1
Important Information – Please read. To reduce the maximum rated speed from 2100 to
1800 rpm, set progressive shift as follows:
You must use the updated fax request in these • LG1 rpm limit - 1800
instructions, or request the mainframe update to “DDEC • LG1 max rpm - 1800
IV,” otherwise the wrong calibration could be assigned. • LG1 max mph - 12
• LG2 rpm limit - 1800
The DDEC IV ECM in this kit is only for use with • LG2 max rpm - 1800
12-volt systems. • LG2 max mph - 44
• HG max rph - 1800
Within the ratings listed, you will find the original DDEC • HG min mph - 45
II-III ratings and a cross-reference to the comparable
DDEC IV version.
DDEC II to DDEC IV UPC groups are listed in Table 2.
With the following features now found within the DDEC To ensure that the engine is serviced properly after
system, it is possible to cover a wide variety of requests being converted from DDEC II to DDEC IV, and to
with fewer ratings: ensure that other modifications may be made, DDC’s
• Low gear torque limiting will modify the max. unit history file must be updated. If this is not done,
torque for the application. subsequent engine service and/or repair work might be
• Progressive shift will limit the max RPM for the done using incorrect parts. Complete the attached FAX
user. form and send it to the DDC Customer Support Center.
See Figure 5.
Table 2 1991-1993 Series 60 DDEC II to DDEC IV Conversion – On-Highway Trucks with Manual
Transmissions
Set/ Res/
Cruise Enable DDR/DDDL DDR/DDDL Okay
Step Coast Accel Go To
Switch Readout Display ?
Switch Switch
Off Yes —
Set/Coast
1 On Off Off Refer to Sec. 10.7 of DDEC III/IV
On No
SECM TS Manual
Refer to Sec. 10.7 of DDEC III/IV
Set/Coast Off No
2 On On Off SECM TS Manual
On Yes —
Off Yes —
Res/Accel
3 On Off Off Refer to Sec. 10.7 of DDEC III/IV
On No
SECM TS Manual
Refer to Sec. 10.7 of DDEC III/IV
Res/Accel Off No
4 On Off On SECM TS Manual
On Yes —
Table 5 Cruise Control Quick Check Table, Testing Set/Coast and Resume/Accel Switches and Wiring