CARDON-OFF DISTANCE CALCULATION FOR GAMMA WORKS

1. Gamma Ray Setup

2. Cardon off Distance


During Open field radiography, the most economic way to achieve radiation safety
distance. Certain distance need to be cardoned off to ensure that the general public
does not receive radiation dose beyond specific limits. The following method used to
cardon off distance.

2 𝑪𝒊∗𝑹𝑯𝑴∗𝑾∗𝑶
D= 𝑷

D = Cardon off distance


Ci = Strength in Curie
RHM = Specific Gammam Ray Constant
W = Workload in Hrs / week
O = Occupancy
P = Public Dose limits per week

3. Calculation
Source : Ir192
Strength : 22 Ci
RHM : 500mr/hr
W : 5hrs per week
O : 1/16 (Open Space - occassional)
P : 2mr/week

2 𝑪𝒊∗𝑹𝑯𝑴∗𝑾∗𝑶
D= 𝑷
2 𝟐𝟐∗𝟓𝟎𝟎∗𝟓∗(𝟏/𝟏𝟔)
D= 𝟐

D = 41.45𝒎𝒕𝒔

For Open Source Radiography a cardon off distance of 41.45mtrs is required.